3
Signature Job: Scale: Date: Sheet Number: 08-08-08 AS NOTED 15-08 Drawn By: JA Checked By: MRIESER of E-1 Rev Description THIS WORK WAS PREPARED BY MARK RIESER OR UNDER MY SUPERVISION. Blanca Terrace CONDOMINIUMS 60 Blanca Lane Watsonville, CA 95076 25 2 CD T HB C W F GS 220 fluor LV 220 HB GS 220 HB GS 220 GS HB fluor fluor fluor fluor FOR GARAGE DOOR OPENER, TYP FOR GARAGE DOOR OPENER, TYP FOR GARAGE DOOR OPENER, TYP TYPE A Units 6 & 13 TYPE B Units 5 & 12 TYPE C Units 4 & 11 GD F F F GD GD F F F F F F F F F PHOTOSENSOR MOTION SENSOR MOTION SENSOR MOTION SENSOR MOTION SENSOR PHOTOSENSOR MOTION SENSOR PHOTOSENSOR MOTION SENSOR SCALE: 1/4" = 1'-0" 1 ELECTRICAL PLAN - BLDG 1 & 3 / STORY 1 CEILING SURFACE MOUNTED INCANDESCENT LIGHT FIXTURE JUNCTION BOX RECESSED CEILING MOUNTED FLUORESCENT LIGHT FIXTURE, TYPICAL THROUGHOUT RECESSED CEILING MOUNTED LOW VOLTAGE LIGHT FIXTURE ( IC RATED ) TELEPHONE (4 PAIR CAT 5 - HOME RUNS) SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE EXHAUST FAN / LIGHT FIXTURE COMBINATION - FLUORESCENT F/ T-24 COMPLIANCE EXTERIOR FLOOD LIGHT UNDER COUNTER FLUORESCENT LIGHT FIXTURE PROVIDES GEN LIGHTING @ KITCHEN (ELECTRONIC BALUSTER) SINGLE POLE DIMMER SWITCH TELEVISION COAX CABLE (HOME RUNS) WARM AIR SUPPLY (FLOOR) WARM AIR SUPPLY (CEILING) WARM AIR SUPPLY (TOE KICK) WARM AIR SUPPLY (WALL) COLD AIR RETURN GAS OUTLET SINGLE POLE SWITCH SMOKE DETECTOR AC / DC INTER CONNECTED EXHAUST FAN THREE WAY SWITCH LEGEND 110V RECEPTACLE THREE WAY DIMMER SWITCH ELECTRICAL SUB PANEL 110V WATER PROOF (WP) RECEPTACLE (GROUND FAULT INTERRUPTED CIRCUIT) 110V RECEPTACLE (GROUND FAULT INTERRUPTED CIRCUIT) 110V DOUBLE DUPLEX RECEPTACLE 220V RECEPTACLE WALL MOUNTED INCANDESCENT LIGHT FIXTURE GFI SETBACK THERMOSTAT HOSE BIB W/ BACK-FLOW PREVENTION DEVICE FANTECH® INLINE FR SERIES FAN FANTECH® FAN CEILING GRILLE W/ DAMPER STEP LIGHT (LOW VOLTAGE) F OCCUPANCY SENSOR SWITCH FC FIRE-SPRINKLER ( CEILING ) FW FIRE-SPRINKLER ( WALL )

Sample Electrical Plans

Embed Size (px)

Citation preview

Page 1: Sample Electrical Plans

Signature

Job:

Scale:

Date:

Sheet Number:

08-08-08

AS NOTED

15-08

Drawn By:

JA

Checked By:

MRIESER

of

E-1

Rev Description

THIS WORK WAS PREPARED BYMARK RIESER

OR UNDER MY SUPERVISION.

Blan

ca T

er

race

CO

ND

OM

INIU

MS

60 B

lan

ca L

an

e

Watson

vil

le, C

A 9

5076

252

CD

T

HB

C

W

F

GS

220

fluor

LV

220

HB

GS

220

HB

GS

220

GS

HB

fluo

r

fluo

r

fluo

r

fluo

r

FORGARAGE DOOR

OPENER, TYP

FORGARAGE DOOROPENER, TYP

FORGARAGE DOOROPENER, TYP

TYPE AUnits 6 & 13

TYPE BUnits 5 & 12

TYPE CUnits 4 & 11

GD

F F

F

GD GD

F

F

F F

F

F

F F

F

PHOTOSENSOR

MOTION SENSOR

MOTION

SENSOR

MOTION

SENSOR

MOTION

SENSOR

PHOTOSENSOR

MOTION SENSOR

PHOTOSENSOR

MOTION SENSOR

SCALE: 1/4" = 1'-0"1ELECTRICAL PLAN - BLDG 1 & 3 / STORY 1

CEILING SURFACE MOUNTED INCANDESCENT LIGHTFIXTURE

JUNCTION BOX

RECESSED CEILING MOUNTED FLUORESCENT LIGHTFIXTURE, TYPICAL THROUGHOUT

RECESSED CEILING MOUNTED LOW VOLTAGE LIGHTFIXTURE ( IC RATED )

TELEPHONE (4 PAIR CAT 5 - HOME RUNS)

SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE

EXHAUST FAN / LIGHT FIXTURE COMBINATION -FLUORESCENT F/ T-24 COMPLIANCE

EXTERIOR FLOOD LIGHT

UNDER COUNTER FLUORESCENT LIGHT FIXTUREPROVIDES GEN LIGHTING @ KITCHEN(ELECTRONIC BALUSTER)

SINGLE POLE DIMMER SWITCH

TELEVISION COAX CABLE (HOME RUNS)

WARM AIR SUPPLY (FLOOR)

WARM AIR SUPPLY (CEILING)

WARM AIR SUPPLY (TOE KICK)

WARM AIR SUPPLY (WALL)

COLD AIR RETURN

GAS OUTLET

SINGLE POLE SWITCH

SMOKE DETECTOR AC / DC INTER CONNECTED

EXHAUST FAN

THREE WAY SWITCH

LEGEND

110V RECEPTACLE

THREE WAY DIMMER SWITCH

ELECTRICAL SUB PANEL

110V WATER PROOF (WP) RECEPTACLE (GROUNDFAULT INTERRUPTED CIRCUIT)

110V RECEPTACLE (GROUND FAULT INTERRUPTEDCIRCUIT)

110V DOUBLE DUPLEX RECEPTACLE

220V RECEPTACLE

WALL MOUNTED INCANDESCENT LIGHT FIXTURE

GFI

SETBACK THERMOSTAT

HOSE BIB W/ BACK-FLOW PREVENTION DEVICE

FANTECH® INLINE FR SERIES FAN

FANTECH® FAN CEILING GRILLE W/ DAMPER

STEP LIGHT (LOW VOLTAGE)

F

OCCUPANCY SENSOR SWITCH

FC FIRE-SPRINKLER ( CEILING )

FW FIRE-SPRINKLER ( WALL )

Page 2: Sample Electrical Plans

Signature

Job:

Scale:

Date:

Sheet Number:

08-08-08

AS NOTED

15-08

Drawn By:

JA

Checked By:

MRIESER

of

M-1

Rev Description

THIS WORK WAS PREPARED BYMARK RIESER

OR UNDER MY SUPERVISION.

Blan

ca T

er

race

CO

ND

OM

INIU

MS

60 B

lan

ca L

an

e

Watson

vil

le, C

A 9

5076

2510

CD

TYPE AUnits 6 & 13

TYPE BUnits 5 & 12

TYPE CUnits 4 & 11

FAU

8

8

8

10

8

8

10

12

8 8

8

FAU

10

8

8

10

88

8

10

8

8

10

FAU

MUST MEET CLEARANCESTO OPENINGIF NOT, BRING TO ROOF

MUST MEET CLEARANCESTO OPENING

IF NOT, BRING TO ROOF

MUST MEET CLEARANCESTO OPENING

IF NOT, BRING TO ROOF

SCALE: 1/4" = 1'-0"1HVAC PLAN - BLDG 1 & 3 / STORY 1

Page 3: Sample Electrical Plans

Signature

Job:

Scale:

Date:

Sheet Number:

08-08-08

AS NOTED

15-08

Drawn By:

JA

Checked By:

MRIESER

of

P-1

Rev Description

THIS WORK WAS PREPARED BYMARK RIESER

OR UNDER MY SUPERVISION.

Blan

ca T

er

race

CO

ND

OM

INIU

MS

60 B

lan

ca L

an

e

Watson

vil

le, C

A 9

5076

2518

CD

TYPE AUnits 6 & 13

TYPE BUnits 5 & 12

TYPE CUnits 4 & 11

SEE CIVIL DWG'S

FOR CONT'

FCO

C W/H

ABV

W4W

4

CW

M

AIN

W4

ABV

W4

W3

W2

V

V

W2

W2

V

CW/H

ABV

W4

ABV

W4

CW

M

AIN

FCO

W4

SEE CIVIL DWG'S

FOR CONT'

CW/H

ABV

V

V

V

W4

ABV

W4

W2

CW/H

ABV

W4

ABV

CW/H

ABV

V

W4

W4

CW

M

AIN

FCO

W4

SEE CIVIL DWG'S

FOR CONT'

CW/H

ABV

V

V

W4

W2

CW/H

ABV

W4

ABV

CW/H

ABV

V

W4

W4

V

V

W2

W4

SCALE: 1/4" = 1'-0"1PLUMBING PLAN - BLDG 1 & 3 / STORY 1

NOTES: UNLESS OTHERWISE SPECIFIED:1. DRAWINGS ARE FOR REFERENCE ONLY.

THE EXACT LOCATIONS AND SIZING MAY VARY

DUE TO STRUCTURAL CONDITIONS

AND SITE CONDITIONS

2. GAS SYSTEM LENGTHS MAY DIFFER FROM

THOSE SHOWN.

3. SUBCONTRACTOR MUST VERIFY ALL SIZES,

LENGTHS AND LOCATIONS WITH ENGINEER

BEFORE WORK CAN BEGIN.

4. SUBCONTRACTOR MUST WALK THE JOB SITE

WITH ENGINEER BEFORE WORK CAN BEGIN.

TO CONFIRM CONSTRUCTION.

LEGEND

V = 2 INCH VENT

W4 = 4 INCH DIAMETER WASTE

W3 = 3 INCH DIAMETER WASTE

W2 = 2 INCH DIAMETER WASTE

ABV = ABOVE

FCO = FLOOR CLEAN OUT

COLD/HOT WATER THROUGH-OUT ROOM

GAS LINE

GAS LINE ABOVE

1/2" DIAMETER, TYPICAL EXCEPT MAIN

CW = COLD WATER

H = HOT WATER

CW/HABV

COLD WATER / HOT WATER ABOVE

CWMAIN = SEE CIVIL PLANS

COLD WATER LINE

HOT WATER LINE