Upload
kim-ciudadano
View
36
Download
0
Embed Size (px)
Citation preview
Signature
Job:
Scale:
Date:
Sheet Number:
08-08-08
AS NOTED
15-08
Drawn By:
JA
Checked By:
MRIESER
of
E-1
Rev Description
THIS WORK WAS PREPARED BYMARK RIESER
OR UNDER MY SUPERVISION.
Blan
ca T
er
race
CO
ND
OM
INIU
MS
60 B
lan
ca L
an
e
Watson
vil
le, C
A 9
5076
252
CD
T
HB
C
W
F
GS
220
fluor
LV
220
HB
GS
220
HB
GS
220
GS
HB
fluo
r
fluo
r
fluo
r
fluo
r
FORGARAGE DOOR
OPENER, TYP
FORGARAGE DOOROPENER, TYP
FORGARAGE DOOROPENER, TYP
TYPE AUnits 6 & 13
TYPE BUnits 5 & 12
TYPE CUnits 4 & 11
GD
F F
F
GD GD
F
F
F F
F
F
F F
F
PHOTOSENSOR
MOTION SENSOR
MOTION
SENSOR
MOTION
SENSOR
MOTION
SENSOR
PHOTOSENSOR
MOTION SENSOR
PHOTOSENSOR
MOTION SENSOR
SCALE: 1/4" = 1'-0"1ELECTRICAL PLAN - BLDG 1 & 3 / STORY 1
CEILING SURFACE MOUNTED INCANDESCENT LIGHTFIXTURE
JUNCTION BOX
RECESSED CEILING MOUNTED FLUORESCENT LIGHTFIXTURE, TYPICAL THROUGHOUT
RECESSED CEILING MOUNTED LOW VOLTAGE LIGHTFIXTURE ( IC RATED )
TELEPHONE (4 PAIR CAT 5 - HOME RUNS)
SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE
EXHAUST FAN / LIGHT FIXTURE COMBINATION -FLUORESCENT F/ T-24 COMPLIANCE
EXTERIOR FLOOD LIGHT
UNDER COUNTER FLUORESCENT LIGHT FIXTUREPROVIDES GEN LIGHTING @ KITCHEN(ELECTRONIC BALUSTER)
SINGLE POLE DIMMER SWITCH
TELEVISION COAX CABLE (HOME RUNS)
WARM AIR SUPPLY (FLOOR)
WARM AIR SUPPLY (CEILING)
WARM AIR SUPPLY (TOE KICK)
WARM AIR SUPPLY (WALL)
COLD AIR RETURN
GAS OUTLET
SINGLE POLE SWITCH
SMOKE DETECTOR AC / DC INTER CONNECTED
EXHAUST FAN
THREE WAY SWITCH
LEGEND
110V RECEPTACLE
THREE WAY DIMMER SWITCH
ELECTRICAL SUB PANEL
110V WATER PROOF (WP) RECEPTACLE (GROUNDFAULT INTERRUPTED CIRCUIT)
110V RECEPTACLE (GROUND FAULT INTERRUPTEDCIRCUIT)
110V DOUBLE DUPLEX RECEPTACLE
220V RECEPTACLE
WALL MOUNTED INCANDESCENT LIGHT FIXTURE
GFI
SETBACK THERMOSTAT
HOSE BIB W/ BACK-FLOW PREVENTION DEVICE
FANTECH® INLINE FR SERIES FAN
FANTECH® FAN CEILING GRILLE W/ DAMPER
STEP LIGHT (LOW VOLTAGE)
F
OCCUPANCY SENSOR SWITCH
FC FIRE-SPRINKLER ( CEILING )
FW FIRE-SPRINKLER ( WALL )
Signature
Job:
Scale:
Date:
Sheet Number:
08-08-08
AS NOTED
15-08
Drawn By:
JA
Checked By:
MRIESER
of
M-1
Rev Description
THIS WORK WAS PREPARED BYMARK RIESER
OR UNDER MY SUPERVISION.
Blan
ca T
er
race
CO
ND
OM
INIU
MS
60 B
lan
ca L
an
e
Watson
vil
le, C
A 9
5076
2510
CD
TYPE AUnits 6 & 13
TYPE BUnits 5 & 12
TYPE CUnits 4 & 11
FAU
8
8
8
10
8
8
10
12
8 8
8
FAU
10
8
8
10
88
8
10
8
8
10
FAU
MUST MEET CLEARANCESTO OPENINGIF NOT, BRING TO ROOF
MUST MEET CLEARANCESTO OPENING
IF NOT, BRING TO ROOF
MUST MEET CLEARANCESTO OPENING
IF NOT, BRING TO ROOF
SCALE: 1/4" = 1'-0"1HVAC PLAN - BLDG 1 & 3 / STORY 1
Signature
Job:
Scale:
Date:
Sheet Number:
08-08-08
AS NOTED
15-08
Drawn By:
JA
Checked By:
MRIESER
of
P-1
Rev Description
THIS WORK WAS PREPARED BYMARK RIESER
OR UNDER MY SUPERVISION.
Blan
ca T
er
race
CO
ND
OM
INIU
MS
60 B
lan
ca L
an
e
Watson
vil
le, C
A 9
5076
2518
CD
TYPE AUnits 6 & 13
TYPE BUnits 5 & 12
TYPE CUnits 4 & 11
SEE CIVIL DWG'S
FOR CONT'
FCO
C W/H
ABV
W4W
4
CW
M
AIN
W4
ABV
W4
W3
W2
V
V
W2
W2
V
CW/H
ABV
W4
ABV
W4
CW
M
AIN
FCO
W4
SEE CIVIL DWG'S
FOR CONT'
CW/H
ABV
V
V
V
W4
ABV
W4
W2
CW/H
ABV
W4
ABV
CW/H
ABV
V
W4
W4
CW
M
AIN
FCO
W4
SEE CIVIL DWG'S
FOR CONT'
CW/H
ABV
V
V
W4
W2
CW/H
ABV
W4
ABV
CW/H
ABV
V
W4
W4
V
V
W2
W4
SCALE: 1/4" = 1'-0"1PLUMBING PLAN - BLDG 1 & 3 / STORY 1
NOTES: UNLESS OTHERWISE SPECIFIED:1. DRAWINGS ARE FOR REFERENCE ONLY.
THE EXACT LOCATIONS AND SIZING MAY VARY
DUE TO STRUCTURAL CONDITIONS
AND SITE CONDITIONS
2. GAS SYSTEM LENGTHS MAY DIFFER FROM
THOSE SHOWN.
3. SUBCONTRACTOR MUST VERIFY ALL SIZES,
LENGTHS AND LOCATIONS WITH ENGINEER
BEFORE WORK CAN BEGIN.
4. SUBCONTRACTOR MUST WALK THE JOB SITE
WITH ENGINEER BEFORE WORK CAN BEGIN.
TO CONFIRM CONSTRUCTION.
LEGEND
V = 2 INCH VENT
W4 = 4 INCH DIAMETER WASTE
W3 = 3 INCH DIAMETER WASTE
W2 = 2 INCH DIAMETER WASTE
ABV = ABOVE
FCO = FLOOR CLEAN OUT
COLD/HOT WATER THROUGH-OUT ROOM
GAS LINE
GAS LINE ABOVE
1/2" DIAMETER, TYPICAL EXCEPT MAIN
CW = COLD WATER
H = HOT WATER
CW/HABV
COLD WATER / HOT WATER ABOVE
CWMAIN = SEE CIVIL PLANS
COLD WATER LINE
HOT WATER LINE