18
©2019 Tecumseh Products Company LLC Lionel Audouy Global Platform Director Tecumseh Products Company May, 2020 S ECTION III (COMMERCIAL) FH² REPLACING FH

S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

©2019 Tecumseh Products Company LLC

Lionel Audouy

Global Platform Director

Tecumseh Products Company – May, 2020

SECTION III (COMMERCIAL)

FH² REPLACING FH

Page 2: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

©2019 Tecumseh Products Company LLC

The Next Generation

Page 3: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

AG

EN

DA

The new FH22

FH2 vs FH 3Similar platforms

Key benefits

Performances

Why FH2 ?1

Acoustic

Footprint

Cross-reference and nomenclature

FH2 vs Competition 4

Summary566

Page 4: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

1- Why FH² ?

67

Page 5: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

FH2 : A Product ready for the future!

► A sustainable solution

► FH² has been designed to be used with Mid-GWP refrigerant and will be the platform

supporting the next Low-GWP generation.

► A significant positive impact on their system

► FH² is more compact, quieter and more efficient in a similar cooling capacity range.

► An easy transition

► Same Reciprocating (Piston) Reliable technology, very well perceived and understood

on commercial system,

► Same footprint …. as our Famous FH range.

Our customers are telling us, they need:

68

Page 6: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

2- The New FH²

69

Page 7: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

FH2: the key Values for our Customers.

Value proposition

►Eco-friendly

Compatible with Mid-GWP refrigerants

R452A, R448A*, R449A*, R513A and will

support R455A/R454C and R1234yf

refrigerants.

► Product offering

Only one size for a full cooling capacity

range. Main European voltages available

from launch.► Robust

Decision to keep reciprocation technology to meet

the rough conditions of commercial refrigeration

applications where reliability is a must.

► Performance

Efficiency is a key differentiator.

FH² has been designed to succeed on our

customers Energy requirements.

► Customization

This platform is delivered from Europe.

It allows to provide many variants in an

efficient way.

* Refer to Tecumseh Guide lines

70

Page 8: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

3- FH² vs FHSimilar platforms

Key benefits

Performances

Acoustic

Footprint

Cross-reference and nomenclature

71

Page 9: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

Same technology (Piston), architecture, number of Cylinders (2), footprint.

Different positions for Tubing/ Spud and terminal

Similar platforms

FH²: Easy transition from FH.

FH FH2

Suction spud/ tube Process

tube in Upper Housing

Discharge spud, Sight glass,

Crank case heater in lower

Housing

Electrical terminal

in upper housing

Electrical terminal in

lower housing

Suction connection Rotalock 1" ¼ - 12UNF 2A

Discharge connection Rotalock 1" ¼ - 12UNF 2A

Suction connection Rotalock 1" ¼ - 12UNF 2A

Discharge connection Rotalock 1" - 14UNS 2A

72

Page 10: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

Key benefits

FH²: keep the best, Exceed key values.

FH2 FH Comments

Efficiency FH2 is 5 to 20% better

Sound (dBA) FH2 is 1 to 3dB quieter with less Low frequencies

Height (mm) 354 350, 370, 390One Height for entire FH2 platform

Compact by 36mm

Models HBP: 4522 to 4544

LBP: 2480 to 2511

HBP: 4522 to 4540

LBP: 2480 to 2511

FH2 has a similar capacity range in

LBP and a wider HBP

Displacement (cm3) 40 to 68 40 to 74FH2 has a better volumetric

efficiency

Advantages

More efficient,

quieter, more

compact and wider

cooling capacity

Reliable design for

“commercial” market

FH2 provides better performances

based on the Tecumseh’s design and

reliability knowledge

73

Page 11: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

LBP Performances

FH²: 15 to 20% better cooling capacity and efficiency

-

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

9,000

10,000

-45 -40 -35 -30 -25 -20 -15 -10

Watt

Evaporating Temp.

Cooling Capacity

TCond 30 Deg C

TCond 50 Deg CTCond 60 Deg C 0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

-45 -40 -35 -30 -25 -20 -15 -10

Evaporating Temp.

COP

TCond 60 Deg CTCond 50 Deg C

TCond 30 Deg C

FH²: FH2511Z-XG1A

FH: TFH2511Z

FH²: FH2511Z-XG1A

FH: TFH2511Z

*The Performances are Subjected to revision

74

Page 12: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

HBP Performances

FH²: 15 to 20% better efficiency

-

2,000

4,000

6,000

8,000

10,000

12,000

14,000

16,000

18,000

20,000

-30 -25 -20 -15 -10 -5 0 5 10 15

Watt

Evaporating Temp.

Cooling Capacity

0.00

1.00

2.00

3.00

4.00

5.00

6.00

7.00

8.00

-30 -25 -20 -15 -10 -5 0 5 10 15

Evaporating Temp.

COP

TCond 30 Deg C

TCond 60 Deg C

TCond 30 Deg C

TCond 60 Deg C

FH²: FH4538Z-XG1A

FH: TFH4540ZFH²: FH4538Z-XG1A

FH: TFH4540Z

*The Performances are Subjected to revision

75

Page 13: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

Acoustic

FH²: significant drop in low frequencies (up to -15dBA) – Quieter in

the appliance

25

30

35

40

45

50

55

60

65

70

75

80

85

dB

A

1/3 Oct (Hz)

TFH2511Z

FH2511Z-XG1A

25

30

35

40

45

50

55

60

65

70

75

80

85

dB

A

1/3 Oct (Hz)

TFH4540Z

FH4538Z-XG1A

LBP modelHBP model

*The Performances are Subjected to revision

76

Page 14: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

Comparison FH vs FH2 (Tube)

Compact

FH FH2

The suction ,discharge and process tube location, orientation

and the diameters are different in FH2 Important to verify the

system tube routing and wiring harness in the application

3 Different heights :350,374,390mm,

Mounting Hole distance 190.5X190.5mmOne Height for FH2:354mm,

190.5X190.5mm Mounting Hole distance

77

Page 15: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

Comparison FH vs FH2 (Spud)

3 Different heights :350,374,390mm,

Mounting Hole distance 190.5X190.5mmOne Height for FH2:354mm,

190.5X190.5mm Mounting Hole distanceFH2FH

Compact

The suction ,discharge Spuds and process tube location

and the diameters are different in FH2 Important to verify the

system tube routing and wiring harness in the application

78

Page 16: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

FH vs FH2 :Model wise Height Summary

FH Model

Height Including Grommets

(mm)FH2 All Models

Height Including Grommets

(mm)

TFH4540Z (KZ,TZ)

390

FH2 354

FH4540Z(FZ,HZ,GZ)

FH4531Z(FZ,HZ,GZ)

FH2480Z(FZ,HZ,GZ)

FH2511Z(FZ,HZ,GZ)

FH4522Z(FZ,HZ,GZ)

374

FH4524Z(FZ,HZ,GZ)

FH4525Y(FZ,HZ,GZ)

TFH4522Z(TZ,KZ)

TFH4524Z(TZ,KZ)

TFH4531Z(TZ,KZ)

TFH4518Y(TZ,KZ)

TFH4525Y(TZ,KZ)

TFH2480Z(TZ,KZ)

TFH2511Z(TZ,KZ)

FH4518Y (FZ,HZ,GZ) 350

79

Page 17: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

Product Range

FH2: A complete range Available

Model XG XC KZ XN

R404A, R452A,

R449A* & R448A*

LBP FH2480Z x x x x

FH2511Z x x x x

FH4522Z x x x

HBP

FH4524Z x x x x

FH4532Z x x x x

FH4538Z x x x x

FH4544Z x x

R134a &R513A HBPFH4518Y x x

FH4525Y x x

Single PhaseXC: 220-240V/50Hz/1~

Previous FZ is replaced by XC

Three PhasesKZ: 220V/50Hz/3~

220V/60Hz/3~

XG: 380-420V/50Hz/3~

460V/60Hz/3~

Previous TZ is replaced by XG

XN voltage will cover

HZ and GZXN: 200-220V/50Hz/1~

208-230V/60Hz/1~

GZ: 208-220V/50Hz/1~

HZ: 208-220V/60Hz/1~* Refer to Tecumseh Guide lines

80

Page 18: S III (COMMERCIAL - RESLUK.COM...R134a &R513A HBP FH4518Y x x FH4525Y x x Single Phase XC: 220-240V/50Hz/1~ Previous FZ is replaced by XC Three Phases KZ: 220V/50Hz/3~ 220V/60Hz/3~

Cross Ref and nomenclature

FH FH²

TFH2480Z-KZ FH2480Z-KZ1A

FH2480Z-FZ FH2480Z-XC3A

TFH2480Z-TZ FH2480Z-XG1A

FH2480Z-GZ FH2480Z-XN3A

FH2480Z-HZ FH2480Z-XN3A

TFH2511Z-KZ FH2511Z-KZ1A

FH2511Z-FZ FH2511Z-XC3A

FH2511Z-FZ FH2511Z-XC3A

TFH2511Z-TZ FH2511Z-XG1A

FH2511Z-GZ FH2511Z-XN3A

FH2511Z-HZ FH2511Z-XN3A

R134a equivalent

FH FH²

TFH4518Y-TZ FH4518Y- XG1A

FH4518Y-FZ FH4518Y-XC3A

FH4525Y-FZ FH4525Y-XC3A

TFH4525Y-TZ FH4525Y-XG1A

FH FH²

TFH4522Z-KZ FH4522Z-KZ1A

FH4522Z-FZ FH4522Z-XC3A

TFH4522Z-TZ FH4522Z-XG1A

TFH4524Z-KZ FH4524Z-KZ1A

FH4524Z-FZ FH4524Z-XC3A

TFH4524Z-TZ FH4524Z-XG1A

FH4524Z-HZ FH4524Z-XN3A

FH4524Z-GZ FH4524Z-XN3A

TFH4531Z-KZ FH4532Z-KZ1A

FH4531Z-FZ FH4532Z-XC3A

TFH4531Z-TZ FH4532Z-XG1A

FH4531Z-HZ FH4532Z-XN3A

FH4531Z-GZ FH4532Z-XN3A

TFH4540Z-KZ FH4538Z-KZ1A

FH4540Z-FZ FH4538Z-XC3A

TFH4540Z-TZ FH4538Z-XG1A

FH4540Z-HZ FH4538Z-XN3A

FH4540Z-GZ FH4538Z-XN3A

FH² will use a new designation like: FH2511Z-XG instead of TFH2511Z

FH FH²

Not Applicable FH4544Z-KZ1A

Not Applicable FH4544Z-XG1A

LBP R404A equivalent HBP R404A equivalent 2 new Models in FH2

81