25
RESIDENTIAL ROOFING Metcom 7 0800 ROOFNZ (0800 766 369) www.metalcraftroofing.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] RRMCM7 00 / 24 COVER SHEET 01 / 24 ROOF RIDGE 02 / 24 SAWTOOTH RIDGE 03 / 24 SAWTOOTH EAVE 04 / 24 ROOF VALLEY 05 / 24 ROOF - CHANGE PITCH 06 / 24 EAVE WITH METALLINE FASCIA 07 / 24 EAVE WITH INTERNAL GUTTER BRACKET 08 / 24 EAVE WITH SNOW STRAP 09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET 10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET 11 / 24 BARGE WITH PROFILED CLADDING 12 / 24 BARGE OVERHANG 13 / 24 PARAPET WITH TRANSVERSE APRON 14 / 24 TRANSVERSE APRON 15 / 24 PARALLEL APRON 16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION 17 / 24 OVER 85mm DIAMETER PIPE PENETRATION 18 / 24 3D-RIDGE TO BARGE JUCTION 19 / 24 3D-DUTCH GABLE 20 / 24 3D-APRON 21 / 24 3D-OVER 85mm DIAMETER PIPE PENETRATION 22 / 24 3D-CHIMNEY PENETRATION 23 / 24 3D-RIDGE/BARGE FLASHINGS 24 / 24 3D-DUTCH GABLE FLASHINGS DETAIL LIST

S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

RESIDENTIAL ROOFING

Metcom 7

0800 ROOFNZ (0800 766 369)www.metalcraftroofing.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

00 / 24 COVER SHEET01 / 24 ROOF RIDGE02 / 24 SAWTOOTH RIDGE03 / 24 SAWTOOTH EAVE04 / 24 ROOF VALLEY05 / 24 ROOF - CHANGE PITCH06 / 24 EAVE WITH METALLINE FASCIA07 / 24 EAVE WITH INTERNAL GUTTER BRACKET08 / 24 EAVE WITH SNOW STRAP09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET11 / 24 BARGE WITH PROFILED CLADDING12 / 24 BARGE OVERHANG13 / 24 PARAPET WITH TRANSVERSE APRON14 / 24 TRANSVERSE APRON15 / 24 PARALLEL APRON16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION17 / 24 OVER 85mm DIAMETER PIPE PENETRATION18 / 24 3D-RIDGE TO BARGE JUCTION19 / 24 3D-DUTCH GABLE20 / 24 3D-APRON21 / 24 3D-OVER 85mm DIAMETER PIPE PENETRATION22 / 24 3D-CHIMNEY PENETRATION23 / 24 3D-RIDGE/BARGE FLASHINGS24 / 24 3D-DUTCH GABLE FLASHINGS

DETAIL LIST

Page 2: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

PRE-FINISHED RIDGE CAP FLASHING

STOPENDS TO ROOF CLADDING

ROOF FRAMING

PURLIN

METALCRAFT METCOM 7ROOFING

PRE-FINISHED SELFDRILLING/TAPPINGSCREW WITH RUBBERWASHER

BUILDING PAPERSHOWN DASHED

15.0

NOTCHED EDGEDRESSED OVERMETCOM 7 RIBS

X

5mm

GAP

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

ROOF RIDGE

01 / 242014

Page 3: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

NOTCHED EDGE DRESSED OVERMETCOM 7 RIBS

STOPENDS TO ROOF CLADDING

BUILDING PAPER SHOWNDASHED

PURLINPRE-FINISHED 8g WAFER-TEK SCREW BEDDED INSILICONE

PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER

ROOF OR WALL FRAMING

TIMBER PACKER

FASCIA BOARD

TIMBER PACKER

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

METALCRAFT METCOM 7 ROOFING5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

15.0

Z

X

HEMMED EDGE

PRE-FINISHED SAWTOOTHRIDGE CAP FLASHING

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

MIN. 70mm

X

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mm

MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

X

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

SAWTOOTH RIDGE

02 / 242014

Page 4: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

TIMBER FASCIA

SOFFIT LINING

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWN DASHED

PURLIN

PRE-FINISHED SAWTOOTHRIDGE CAP FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

ROOF FRAMING

15.0

0°X

Z

PRE-FINISHED 8gWAFER-TEK SCREWBEDDED IN SILICONE

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

STOPENDS TO ROOF CLADDING

HEMMED EDGE

NOTCHED EDGE DRESSED OVERMETCOM 7 RIBS

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

MIN. 70mm

X

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mm

MIN. 75mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

X

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

SAWTOOTH EAVE

03 / 242014

Page 5: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

ROOF FRAMING

PURLIN

METALCRAFT METCOM 7ROOFING

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

BUILDING PAPER CONTINUOUS UNDERGUTTER IF COPPER BASED TREATMENTSARE USED. SHOWN DASHED

VALLEY BOARD

PREFINISHED VALLEY GUTTER

MIN

. 50m

m

C

A: OVERALL VALLEY GUTTER WIDTH

B: CLEARANCE BETWEEN ROOFING

C

MIN

. 20mm

SITUATION 1

MAX. CATCHMENT 25m²MIN. ROOF PITCH 8°

MIN. 250mm

MIN. 50mm

MIN. 80mm

SITUATION 2

MAX. CATCHMENT 16m²MIN. ROOF PITCH 12.5°

160mm - 249mm

MIN. 40mm

MIN. 60mm

A

B

C

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND E2 FORFURTHER INFORMATION.

* ROOF PITCH FOR VALLEYS AS PER E2.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

ROOF VALLEY

04 / 242014

Page 6: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

PURLIN

METALCRAFT METCOM 7 ROOFING

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

PURLIN

ROOF FRAMING

STOPENDS TO ROOF CLADDING

PRE-FINISHED CHANGE OFROOF PITCH FLASHING

BUILDING PAPER CONTINUOUSOVER FLASHING SHOWN DASHED

BUILDING PAPER CONTINUOUSUNDER FLASHING SHOWN DASHED

45.0

0°10

.00°

CLEARANCE

MIN. 10mm

X

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

STST OR GALV. FLAT HEADNAIL FOR FLASHING

NOTCHED EDGE DRESSED OVER METCOM 7 RIBS

METALCRAFT METCOM 7 ROOFING

MIN. 250mm

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

X

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 130mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 200mmX

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

ROOF - CHANGE PITCH

05 / 242014

Page 7: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

STST OR GALV. FLAT HEAD NAILFOR FLASHING

METALCRAFT METCOM 7 ROOFING

PRE-FINISHED EAVE FLASHING

BUILDING PAPER SHOWN DASHED

METALLINE™ FASCIA

FASCIA BRACKET

SOFFIT LINING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

METALLINE™ QUAD GUTTER

METALLINE™ QUAD GUTTEROVERSTRAP

TIMBER ROOF FRAMING

15.00°

OVE

RLA

P

MIN

. 35m

m

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

SPRING CLIP

TIMBER PURLIN

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

EAVE WITH METALLINE FASCIA

06 / 242014

Page 8: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

TIMBER FASCIA

METALLINE™ QUAD GUTTER

METALLINE™ QUAD GUTTERINTERNAL BRACKET

15.00°

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWN DASHED

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

OVE

RLA

P

MIN

. 35m

m

PRE-FINISHED 8g WAFER-TEKSCREW

STST OR GALV. FLAT HEAD NAILFOR FLASHING

PRE-FINISHED EAVE FLASHING

SOFFIT LINING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

TIMBER ROOF FRAMING

TIMBER PURLIN

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

EAVE WITH INTERNAL GUTTER BRACKET

07 / 242014

Page 9: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

TIMBER FASCIA

METALLINE™ QUAD GUTTER

METALLINE™ QUAD GUTTERINTERNAL BRACKET

15.00°

SOFFIT LINING

TIMBER ROOF FRAMING

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWNDASHED

OVE

RLA

P

MIN

. 35m

m

TIMBER PURLIN

PRE-FINISHED EAVE FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

STST OR GALV. FLAT HEAD NAIL FORFLASHING

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

SNOW STRAP AS REQUIRED

PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEKSCREW

PRE-FINISHED 8g WAFER-TEKSCREW

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

EAVE WITH SNOW STRAP

08 / 242014

Page 10: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

TIMBER PACKER

FASCIA BOARD

TIMBER PACKER

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

ROOF FRAMING

15.00°

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWN DASHED

OVE

RLA

P

MIN

. 35m

mTIMBER PURLIN

PRE-FINISHED EAVE FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

STST OR GALV. FLAT HEAD NAIL FORFLASHING

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

QUARTER ROUND GUTTER

QUARTER ROUND GUTTERINTERNAL BRACKET

PRE-FINISHED 8g WAFER-TEKSCREW

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

FLUSH EAVE WITH INTERNAL GUTTER BRACKET

09 / 242014

Page 11: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

TIMBER PURLIN

PRE-FINISHED EAVE FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

15.00°

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWN DASHED

TIMBER PACKER

FASCIA BOARD

TIMBER PACKER

WEATHERBOARDS ON CAVITY

BUILDING PAPER SHOWN DASHED

ROOF FRAMING

OVE

RLA

P

MIN

. 35m

m

STST OR GALV. FLAT HEAD NAIL FORFLASHING

OR AS REQUIREDMIN. 50mm

MIN. 125 mm

QUARTER ROUND GUTTER

QUARTER ROUND GUTTEREXTERNAL BRACKET

PRE-FINISHED 8g WAFER-TEKSCREW

EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

FLUSH EAVE WITH EXTERNAL GUTTER BRACKET

10 / 242014

Page 12: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

TIMBER PACKER

BARGE BOARD

PRE-FINISHEDBARGE FLASHING

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWN DASHED

PURLIN

WEATHERBOARDSON CAVITY

BUILDING PAPER SHOWNDASHED

PRE-FINISHED 8g WAFER-TEKSCREW BEDDED IN SILICONE

ROOF FRAMING

TIMBER PACKER

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

HEMMED EDGE

Z

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

Y

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

AT LEAST TWO CRESTS

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 70mm

Y

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METCOM 7)

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METCOM 7)

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Y

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate Sheet 1 : 2

BARGE WITH PROFILED CLADDING

11 / 242014

Page 13: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

PRE-FINISHED BARGE FLASHING

METALCRAFT METCOM 7 ROOFING

FLY RAFTER

BARGE BOARD

BUILDING PAPERSHOWN DASHED

PURLIN

SOFFIT LINING

PRE-FINISHED 8gWAFER-TEK SCREWBEDDED IN SILICONE

Z

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

5 GAP

20

15

ALTERNATIVE OPTIONBIRDS BEAK EDGE

HEMMED EDGE

Y

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

AT LEAST TWO CRESTS

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 70mm

Y

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

AT LEAST TWO CRESTS

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METCOM 7)

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

ONE RIB, TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METCOM 7)

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Y

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate Sheet 1 : 2

BARGE OVERHANG

12 / 242014

Page 14: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

15.0

MIN

. 5.0

GN

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

TIMBER PACKER

BARGE BOARD

WEATHERBOARDSON CAVITY

BUILDING PAPER SHOWNDASHED

PRE-FINISHED PARAPETCAP FLASHING

TIMBER PACKER

BUILDING PAPER TO PROVIDESEPARATION OF METAL CAPPINGAND TIMBER SHOWN DASHED

TIMBER PURLIN

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWN DASHEDWALL FRAMING ROOF FRAMING

PRE-FINISHED APRON FLASHING

TIMBER NOG FOR FIXINGAPRON FLASHING

CONTINUOUS TIMBER PACKING

STST OR GALV.FLAT HEAD NAILFOR FLASHING

PRE-FINISHED SELFDRILLING / TAPPINGSCREW WITHRUBBER WASHER

PRE-FINISHED 8gWAFER-TEK SCREWBEDDED INSILICONE

Z

NOTCHED EDGE DRESSED OVERMETCOM 7 RIBS

STOPENDS TO ROOFCLADDING

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

MIN. 50mm

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

MIN. 70mm

G

N

L

Z

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm

MIN. 90mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 100mm(VERTICALLY DOWN FACE - PROFILED)

G

N

L

Z

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

PARAPET WITH TRANSVERSE APRON

13 / 242014

Page 15: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

* METCOM 7 MIN. ROOF PITCH = 3°

15.0

GN

L

STOPENDS TO ROOF CLADDING

ROOF FRAMING

WALL FRAMING

PVC CAVITY CLOSER

WEATHERBOARDS ON CAVITY

CANT STRIP PACKER

NOG FOR FIXING APRONFLASHING

STST OR GALV. FLAT HEADNAIL FOR FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

METALCRAFT METCOM 7 ROOFING

BUILDING PAPER SHOWN DASHED

PRE-FINISHED APRON FLASHING

BUILDING PAPER OVERFLASHING SHOWN DASHED

BUILDING PAPER SHOWN DASHED

PURLIN

NOTCHED EDGE DRESSED OVERMETCOM 7 RIBS

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

MIN. 130mm(EXCLUDDING ANY NOTCHED EDGEOR TURN-DOWN TO ROOFING)

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm(EXCLUDDING ANY NOTCHED EDGE ORTURN-DOWN TO ROOFING)

G

N

L

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

MIN. 200mm

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

MIN. 150mm

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

MIN. 200mm

G

N

L

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 2

TRANSVERSE APRON

14 / 242014

Page 16: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

PURLIN

GN

PRE-FINISHEDAPRON FLASHING

WEATHERBOARDS ON CAVITY

CANT STRIPPACKER

BUILDING PAPER OVERFLASHING SHOWN DASHED

STST OR GALV. FLATHEAD NAIL FOR FIXING

NOG FOR FIXINGAPRON FLASHING

PVC CAVITY CLOSER

METALCRAFT METCOM 7 ROOFING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

M

WALL FRAMING

BUILDING PAPER SHOWNDASHED

ROOF FRAMING

5mm

GAP

SITUATION 1

1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

SITUATION 2

1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

G

N

M

SITUATION 3

1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

MIN. 35mm

MIN. 75mm

AT LEAST TWO CRESTS

PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

25mm

MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

ONE RIB (TRAPEZOIDAL & TRAY)2 CORRUGATIONS (METCOM 7)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

25mm

MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - SMOOTH)MIN. 100mm + HEM OR 125mm(VERTICALLY UP FACE - PROFILED)

TWO RIBS (<20mm) (TRAPEZOIDAL & TRAY)3 CORRUGATIONS (METCOM 7)

G

N

M

PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

ScaleDate Sheet 1 : 2

PARALLEL APRON

15 / 242014

Page 17: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.10°and MAX. 45°- PIPE DIAMETER MAX. 85mm 15.00°

* MIN. 10° FOR PIPE PENETRATION

METALCRAFT METCOM 7 ROOFING

EPDM FLEXIBLE CONE SLEEVE MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN.REFER TO MRM CODE OFPRACTICE VERSION 2 2/2012.

BUILDING PAPER SHOWN DASHED

METALCRAFT METCOM 7 ROOFING

PIPE (PIPE DIAMETER ≤ 85mm)

EPDM FLEXIBLE CONE SLEEVE

BUILDING PAPER SHOWN DASHED

MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN.REFER TO MRM CODE OF PRACTICEVERSION 2 2/2012.

TIMBER PURLIN

ROOF FRAMINGPRE-FINISHED SELFDRILLING/TAPPINGSCREW WITH RUBBERWASHER

TIMBER PURLIN

ROOF FRAMING

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 5

MAX. 85mm DIAMETER PIPE PENETRATION

16 / 242014

Page 18: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.10°- PIPE DIAMETER OVER 85mm AND MAX. 500mm- PIPE TO BE POSITIONED AS CLOSE TO ROOF RIDGEAS POSSIBLE

L

PRE-FINISHED SOAKER FLASHING UNDERPRE-FINISHED ROOF RIDGE CAPFLASHING

PIPE (85mm > PIPE DIAMETER ≤ 500mm)

EPDM FLEXIBLE CONE SLEEVE

METALCRAFT METCOM 7 ROOFING

MALLEABLE FLANGE, SCREW OR RIVET FIXED,AND SEALED TO ROOFING PROFILE. FITNEOPRENE WASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN. REFER TO MRMCODE OF PRACTICE VERSION 2 2/2012. PRE-FINISHED SOAKER FLASHING WITH

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

METALCRAFT METCOM 7 ROOFING

PURLIN

ROOF FRAMING

PRE-FINISHEDROOF RIDGECAP FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

EPDM FLEXIBLE CONE SLEEVE

NOGS BETWEEN PURLINS FORPENETRATION

5mm

GAP

5mm

GAP

15.00°

* MIN. 10° FOR PIPE PENETRATION

PURLIN

BUILDING PAPER SHOWN DASHED

ROOF FRAMING

X

M

REFER TO SHEET NO. 14/24 TRANSVERSE APRON

REFER TO SHEET NO. 16/24 PARALLEL APRON

REFER TO SHEET NO. 01/24 ROOF RIDGE

L

M

X

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7

- BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

* - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

ScaleDate Sheet 1 : 5

OVER 85mm DIAMETER PIPE PENETRATION

17 / 242014

Page 19: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

PRE-FINISHED RIDGE CAPFLASHING

METALCRAFT METCOM 7ROOFING

PRE-FINISHED BARGE FLASHING

PURLIN

ROOF FRAMING

FASCIA BOARD

WALL CLADDING ON CAVITY

WALL FRAMING

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATION ONFLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7 ScaleDate Sheet

3D-RIDGE TO BARGE JUCTION

18 / 242014

Page 20: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

PRE-FINISHED RIDGE FLASHING

METALCRAFT METCOM 7 ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

PRE-FINISHED BARGE FLASHING

PRE-FINISHED APRONFLASHING

PRE-FINISHED HIP FLASHING

GUTTER

FASCIA BOARD

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

WALL CLADDING ON CAVITY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7 ScaleDate Sheet

3D-DUTCH GABLE

19 / 242014

Page 21: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

GUTTER

METALCRAFT T-RIB ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

WALL CLADDING ON CAVITY

PRE-FINISHED APRON FLASHINGWITH HEMMED EDGE

PRE-FINISHED APRON DIVERTER

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDE METALROOF FLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.

WALL CLADDING ON CAVITY

FASCIA BOARD

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7 ScaleDate Sheet

3D-APRON

20 / 242014

Page 22: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

PRE-FINISHED SOAKER FLASHING

EPDM FLEXIBLE CONE SLEEVE

MALLEABLE FLANGE, SCREWOR RIVET FIXED, AND SEALEDTO ROOFING PROFILE. FITNEOPRENE WASHERS TO ALLSCREW FIXINGS. FITTED ON 45°ANGLE IN PLAN. REFER TO MRMCODE OF PRACTICE VERSION 22/2012.

PRE-FINISHED ROOF RIDGEFLASHING

PIPE (DIAMETER OVER 85mmDIAMETER)

METALCRAFT METCOM 7ROOFING

PRE-FINISHED ROOF BARGEFLASHING

PRE-FINISHED SOAKERFLASHING LINE UNDER PRE-FINISHED ROOF RIDGE FLASHING

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDEMETAL ROOF FLASHINGS FORFURTHER INFORMATION ONFLASHING COVER WIDTHS.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7 ScaleDate Sheet

3D-OVER 85mm DIAMETER PIPE PENETRATION

21 / 242014

Page 23: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

METALCRAFT METCOM 7ROOFING TURN DOWN INTOGUTTER

PRE-FINISHED APRONFLASHING

WALL CLADDING ON CAVITY

PREFINISHED VALLEY GUTTERPURLIN

PRE-FINISHED SOAKERFLASHING

VALLEY BOARD

ROOF FRAMING

MIN

. 110

mm

UPS

TAN

D

MIN. 110mm UPSTANDPRE-FINISHED 1.6mmALUMINIUM WELDEDSOAKER FLASHING

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATION ONFLASHING COVER WIDTHS.

DIVERTER FLASHING ONUPPER SIDE OF CHIMNEY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7 ScaleDate Sheet

3D-CHIMNEY PENETRATION

22 / 242014

Page 24: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7 ScaleDate Sheet

3D-RIDGE/BARGE FLASHINGS

23 / 242014

OPTION 1

RIDGE CAPFLASHING

ADDITIONALSADDLEFLASHING

BARGEFLASHING

RIDGE CAPFLASHING

ADDITIONALSADDLEFLASHING

BARGEFLASHING

OPTION 2

* PLEASE REFER TO MRM CODEOF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITEGUIDE METAL ROOF FLASHINGSFOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

Page 25: S: 5 Metalcraft Roofing01 BIMDetailsMetcom 7RRMCM7 ... · * metcom 7 min. roof pitch = 3° pre-finished ridge cap flashing stopends to roof cladding roof framing purlin metalcraft

(3) PRE-FINISHED 3DSADDLE FLASHING

(4) PRE-FINISHEDBARGE FLASHING

(2) PRE-FINISHEDAPRON FLASHING

(1) PRE-FINISHED HIP FLASHING

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL ROOFINGMetcom 7

RRMCM7 ScaleDate Sheet

3D-DUTCH GABLE FLASHINGS

24 / 242014

* PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.