Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).
FCC PART 97 TEST REPORT
For
Henan Eshow Electronic Commerce Co.,Ltd.
Room 722, Sanjiang Building, No.170 Nanyang Road, HuijiDistrict, Zhengzhou, Henan, China
Models: RT29 Multiple Models: RT29S
Report Type:
Amended Report
Product Type:
Two Way Radio
Report Number:
RXM180727055-00A1
Report Date:
2018-08-07
Reviewed By:
Jerry Zhang EMC Manager
Test Laboratory:
Bay Area Compliant Laboratories Corp. (Dongguan) No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 2 of 48
TABLE OF CONTENTS
DOCUMENT REVISION HISTORY ......................................................................................................................... 4
GENERAL INFORMATION ....................................................................................................................................... 5
PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 5 OBJECTIVE ................................................................................................................................................................... 5 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 5 TEST METHODOLOGY .................................................................................................................................................. 5 TEST FACILITY ............................................................................................................................................................. 5
SYSTEM TEST CONFIGURATION .......................................................................................................................... 6
DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 6 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 6
SUMMARY OF TEST RESULTS ............................................................................................................................... 7
FCC §2.1093 - RF EXPOSURE INFORMATION ..................................................................................................... 8
APPLICABLE STANDARD .............................................................................................................................................. 8 TEST RESULT ............................................................................................................................................................... 8
FCC §2.1046 & §97.313- RF OUTPUT POWER ....................................................................................................... 9
APPLICABLE STANDARD .............................................................................................................................................. 9 TEST PROCEDURE ........................................................................................................................................................ 9 TEST EQUIPMENT LIST AND DETAILS ........................................................................................................................... 9 TEST DATA ................................................................................................................................................................ 10
FCC §2.1047 - MODULATION CHARACTERISTIC ............................................................................................ 11
APPLICABLE STANDARD ............................................................................................................................................ 11 TEST PROCEDURE ...................................................................................................................................................... 11 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 11 TEST DATA ................................................................................................................................................................ 11
FCC §2.1049&§97.305&§97.307 – OCCUPIED BANDWIDTH ............................................................................. 16
APPLICABLE STANDARD ............................................................................................................................................ 16 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 16 TEST PROCEDURE ...................................................................................................................................................... 16 TEST DATA ................................................................................................................................................................ 16
FCC §2.1051& §97.307 - SPURIOUS EMISSIONS AT ANTENNA TERMINALS ............................................. 19
APPLICABLE STANDARD ............................................................................................................................................ 19 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 19 TEST PROCEDURE ...................................................................................................................................................... 20 TEST DATA ................................................................................................................................................................ 20
FCC §2.1053 & §97.307 - RADIATED SPURIOUS EMISSIONS .......................................................................... 23
APPLICABLE STANDARD ............................................................................................................................................ 23 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 23 TEST PROCEDURE ...................................................................................................................................................... 23 TEST DATA ................................................................................................................................................................ 24
FCC §2.1055 - FREQUENCY STABILITY ............................................................................................................. 26
APPLICABLE STANDARD ............................................................................................................................................ 26 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 26
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 3 of 48
TEST PROCEDURE ...................................................................................................................................................... 26 TEST DATA ................................................................................................................................................................ 26
EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS ................................................................................................ 28
EUT – ALL VIEW ....................................................................................................................................................... 28 EUT – ADAPTER TOP VIEW ....................................................................................................................................... 28 EUT – ADAPTER LABEL VIEW ................................................................................................................................... 29 EUT – TOP VIEW ....................................................................................................................................................... 29 EUT – BOTTOM VIEW ................................................................................................................................................ 30 EUT – SIDE VIEW ...................................................................................................................................................... 30 EUT –SIDE VIEW ....................................................................................................................................................... 31 EUT –SIDE VIEW ....................................................................................................................................................... 31 EUT – SIDE VIEW ...................................................................................................................................................... 32 EUT –PORT VIEW ...................................................................................................................................................... 32 EUT – TOP VIEW ....................................................................................................................................................... 33 EUT – BOTTOM VIEW ................................................................................................................................................ 33 EUT – SIDE VIEW ...................................................................................................................................................... 34 EUT –SIDE VIEW ....................................................................................................................................................... 34 EUT –SIDE VIEW ....................................................................................................................................................... 35 EUT – BATTERY LABEL VIEW ................................................................................................................................... 37 EUT –UNCOVER-1 VIEW ........................................................................................................................................... 38 EUT – MAIN BOARD BOTTOM VIEW ......................................................................................................................... 40 EUT – CHARGING BASE TOP VIEW ............................................................................................................................ 41 EUT – CHARGING BASE BOTTOM VIEW .................................................................................................................... 42 EUT – UNCOVER VIEW .............................................................................................................................................. 42 EUT – UNCOVER VIEW .............................................................................................................................................. 43 EUT – SUBBOARD TOP VIEW ..................................................................................................................................... 43 EUT – SUBBOARD BOTTOM VIEW ............................................................................................................................. 44 EUT – ANTENNA VIEW .............................................................................................................................................. 44 EUT – ANTENNA PORT VIEW .................................................................................................................................... 45
EXHIBIT B - TEST SETUP PHOTOGRAPHS ....................................................................................................... 46
RADIATED EMISSIONS VIEW (BELOW 1GHZ)-RT29 .................................................................................................. 46 RADIATED EMISSION VIEW (ABOVE 1 GHZ)-RT29 ................................................................................................... 46 RADIATED EMISSIONS VIEW (BELOW 1GHZ)-RT29S ................................................................................................ 47 RADIATED EMISSION VIEW (ABOVE 1 GHZ)-RT29S ................................................................................................. 47
EXHIBIT C – DECLARATION LETTER ............................................................................................................... 48
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 4 of 48
DOCUMENT REVISION HISTORY
Revision Number Report Number Description of Revision Date of Revision
0 RXM180530052-00 Original Report 2018-07-11
1 RXM180727055-00A1 Amended Report 2018-08-07
Note: This is the amended report application RXM180727055-00A1 of the device, which was based on the original report RXM180530052-00. The differences between them as following: 1. Change the applicant to “Henan Eshow Electronic Commerce Co.,Ltd. (Address: Room 722, Sanjiang Building, No.170 Nanyang Road, HuijiDistrict, Zhengzhou, Henan, China)”. 2. Change the manufacturer to “Shenzhen Retevis Technology Co.,Ltd. (Address: Room 700, 7/F, 13-C, Zhonghaixin Science&Technology Park, No.12 Ganli 6th Road, Buji Street, Longgang District, Shenzhen, China)”. 3. Change the model name to “RT29, RT29S”. 4. Change the trade name to “RETEVIS”. 5. Change the product name to “Two Way Radio”. 6. For the appearance, change the silk screen. The changes between the previous device and the current one are stated and guaranteed by the applicant, the differences between them will not affect the test result, we will keep the test data, test photos, but update the related EUT photos.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 5 of 48
GENERAL INFORMATION Product Description for Equipment under Test (EUT)
EUT Name: Two Way Radio
EUT Models: RT29
Multiple Models: RT29S Rated Input Voltage: DC7.4
Nominal Adapter Information
Model: NLA050120W1A6
Input: AC 100-240V
Output: DC 12V
External Dimension: 61cm(L)*35cm(W)* 116cm(H)
Serial Number: 180530052
EUT Received Date: 2018.05.30
Note:The series product,models RT29, RT29S are electrically identical,we selected RT29 for fully testing, the details was explained in the attached declaration letter. Objective This test report is prepared on behalf of Henan Eshow Electronic Commerce Co.,Ltd. in accordance with Part 2, Part 97 of the Federal Communications Commission rules. Related Submittal(s)/Grant(s) No related submittal(s). Test Methodology All tests and measurements indicated in this document were performed in accordance with the Code of federal Regulations Title 47 Part 2, Sub-part J as well as the following individual parts: Part 97 – Private Land Two-Way Radio Service Applicable Standards: TIA-603-D. All emissions measurement was performed and Bay Area Compliant Laboratories Corp. (Dongguan). The radiated testing was performed at an antenna-to-EUT distance of 3 meters. Test Facility The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China. The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220. The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 6 of 48
SYSTEM TEST CONFIGURATION Description of Test Configuration The system was configured for testing in a test mode.
Frequency Band 420-450MHz
Modulation Mode FM
Channel Spacing 12.5kHz/25kHz
Output Power High: 4W, Low: 1W
Support Equipment List and Details
Block Diagram of Test Setup
Manufacturer Description Model Serial Number
/ Load / /
1.5 M eter
1.0 Meter
Non-Conductive Table 80 cm above G round Plane
EUT
Non‐conductive table
150 cm above Ground Plane
Load
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 7 of 48
SUMMARY OF TEST RESULTS
FCC Rules Description of Test Results
FCC§1.1307 & §2.1093 RF exposure Compliant*
§2.1046;§97.313 RF Output Power Compliant*
§2.1047 Modulation Characteristic Compliant*
§2.1049;§97.305; §97.307
Occupied Bandwidth & Emission Mask Compliant*
§2.1051§97.307 Spurious Emission at Antenna Terminal Compliant*
§2.1053;§97.307 Spurious Radiated Emissions Compliant*
§2.1055 Frequency Stability Compliant*
Note : Compliant*: Test data is copied from report RXM180530052-00, which was published by Bay Area Compliance Laboratories Corp. (Dongguan) on 2018-07-11.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 8 of 48
FCC §2.1093 - RF EXPOSURE INFORMATION Applicable Standard According to FCC §2.1093 and §1.1307(b) (1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. Test Result Please refer to SAR Report Number: RXM180727055-20A1.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 9 of 48
FCC §2.1046 & §97.313- RF OUTPUT POWER Applicable Standard FCC §2.1046 and §97.313. Test Procedure Conducted RF Output Power: TIA-603-D section 2.2.1 The RF output of the transmitter was connected to the input of the spectrum analyzer through sufficient attenuation. Spectrum Analyzer setting:
RBW VBW
100 kHz 300 kHz
Test Equipment List and Details
Manufacturer Description Model Serial NumberCalibration
Date Calibration Due Date
Rohde & Schwarz Signal Analyzer FSIQ26 831929/005 2017-08-31 2018-08-31
Unknown Coaxial Cable C-SJ00-0010 C0010/01 Each time N/A
HP RF
Communications Test Set
8920A 00 235 2017-07-11 2018-07-11
E-Microwave Blocking Control EMDCB-00036 0E01201047 2018-05-06 2019-05-06
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI).
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 10 of 48
Test Data
Environmental Conditions
Temperature: 27.7 C
Relative Humidity: 38 %
ATM Pressure: 101.3 kPa
The testing was performed by Andy Huang on 2018-06-13.
Test Result: Compliant. Please refer to following tables.
Modulation Mode
Channel Separation
fc Reading (W)
MHz High Power
Level Low Power
Level
FM
12.5kHz
420.0125 3.61 0.74
435 3.66 0.75
449.9875 3.73 0.75
FM
25kHz
420.0125 3.61 0.74
435 3.63 0.75
449.9875 3.72 0.76
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 11 of 48
FCC §2.1047 - MODULATION CHARACTERISTIC Applicable Standard FCC§2.1047
(a) Equipment which utilizes voice modulated communication shall show the frequency response of the audio modulating circuit over a range of 100 to 5000 Hz. for equipment which is required to have a low pass filter, the frequency response of the filter, or all of the circuitry installed between the modulation limited and the modulated stage shall be supplied.
(b) Equipment which employs modulation limiting, a curve showing the percentage of modulation versus the modulation input voltage shall be supplied.
Test Procedure Test Method: TIA/EIA-603D 2.2.3 Test Equipment List and Details
Manufacturer Description Model Serial
Number Calibration
Date Calibration Due Date
Rohde & Schwarz Signal Analyzer FSIQ26 831929/005 2017-08-31 2018-08-31
Unknown Coaxial Cable C-SJ00-0010 C0010/01 Each time N/A
HP RF
Communications Test Set
8920A 00 235 2017-07-11 2018-07-11
E-Microwave Blocking Control EMDCB-00036 0E01201047 2018-05-06 2019-05-06
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI).
Test Data
Environmental Conditions
Temperature: 27.7 C
Relative Humidity: 38 %
ATM Pressure: 101.3 kPa
The testing was performed by Andy Huang on 2018-06-13.
Test Result: Compliant. Please refer to following table and plots.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 12 of 48
MODULATION LIMITING
Carrier Frequency: 435 MHz, Channel Spacing = 12.5 kHz
Audio Frequency (Hz)
Instantaneous Steady-state Limit [kHz]
Deviation (@+20dB)
[kHz]
Deviation (@-20dB)
[kHz]
Deviation (@+20dB)
[kHz]
Deviation (@-20dB)
[kHz]
300 0.84 0.18 0.8 0.15 2.5
400 1.05 0.21 1.02 0.17 2.5
500 1.3 0.24 1.24 0.19 2.5
600 1.58 0.26 1.54 0.2 2.5
700 1.86 0.25 1.79 0.22 2.5
800 1.97 0.22 1.93 0.19 2.5
900 2.27 0.26 2.22 0.23 2.5
1000 2.36 0.32 2.32 0.25 2.5
1200 2.41 0.34 2.34 0.28 2.5
1400 2.42 0.36 2.36 0.31 2.5
1600 2.4 0.39 2.37 0.33 2.5
1800 2.41 0.42 2.35 0.37 2.5
2000 2.39 0.42 2.35 0.38 2.5
2200 2.4 0.43 2.36 0.39 2.5
2400 2.37 0.48 2.34 0.42 2.5
2600 2.4 0.52 2.35 0.45 2.5
2800 2.42 0.53 2.37 0.47 2.5
3000 2.45 0.54 2.38 0.48 2.5
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 13 of 48
Carrier Frequency: 435 MHz, Channel Spacing = 25 kHz
Audio Frequency (Hz)
Instantaneous Steady-state Limit [kHz]
Deviation (@+20dB)
[kHz]
Deviation (@-20dB)
[kHz]
Deviation (@+20dB)
[kHz]
Deviation (@-20dB)
[kHz]
300 1.61 0.27 1.52 0.18 5
400 2.14 0.33 2.01 0.21 5
500 2.58 0.33 2.48 0.24 5
600 3.24 0.37 3.1 0.28 5
700 3.75 0.38 3.63 0.31 5
800 4.08 0.43 3.91 0.34 5
900 4.68 0.49 4.53 0.37 5
1000 4.74 0.49 4.57 0.41 5
1200 4.74 0.58 4.59 0.46 5
1400 4.74 0.61 4.57 0.51 5
1600 4.69 0.69 4.58 0.58 5
1800 4.72 0.69 4.59 0.61 5
2000 4.76 0.79 4.61 0.67 5
2200 4.72 0.8 4.59 0.69 5
2400 4.71 0.83 4.57 0.75 5
2600 4.69 0.87 4.59 0.79 5
2800 4.68 0.93 4.58 0.83 5
3000 4.78 0.91 4.62 0.82 5
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 14 of 48
Audio Frequency Response
Carrier Frequency: 435 MHz, Channel Spacing = 12.5 kHz
Audio Frequency (Hz) Response Attenuation (dB)
300 -12.82
400 -9.51
500 -7.06
600 -5.20
700 -3.81
800 -2.49
900 -1.14
1000 0.00
1200 1.24
1400 2.70
1600 3.82
1800 4.41
2000 5.58
2200 5.92
2400 6.72
2600 7.29
2800 7.63
3000 7.81
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 15 of 48
Carrier Frequency: 435 MHz, Channel Spacing = 25 kHz
Audio Frequency (Hz) Response Attenuation (dB)
300 -13.73 400 -9.86
500 -7.23
600 -5.26 700 -3.86
800 -2.53
900 -1.14
1000 0.00
1200 1.27
1400 2.74
1600 3.88
1800 4.46
2000 5.63
2200 5.95
2400 6.76
2600 7.34
2800 7.66
3000 7.86
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 16 of 48
FCC §2.1049&§97.305&§97.307 – OCCUPIED BANDWIDTH Applicable Standard FCC §2.1049, §97.305 and §97.307 The authorized bandwidth is 100 kHz. Test Equipment List and Details
Manufacturer Description Model Serial
Number Calibration
Date Calibration Due Date
Rohde & Schwarz Signal Analyzer FSIQ26 831929/005 2017-08-31 2018-08-31
Unknown Coaxial Cable C-SJ00-0010 C0010/01 Each time N/A
HP RF Communications
Test Set 8920A 00 235 2017-07-11 2018-07-11
E-Microwave Blocking Control EMDCB-00036 0E01201047 2018-05-06 2019-05-06
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI).
Test Procedure The RF output of the transmitter was connected to the input of the spectrum analyzer through sufficient attenuation. Test Data
Environmental Conditions
Temperature: 27.7C
Relative Humidity: 38 %
ATM Pressure: 101.3 kPa
The testing was performed by Andy Huang on 2018-06-13.
Test Result: Compliant. Please refer to the following tables and plots.
Modulation Mode
Channel Separation
fc 99% Occupied
Bandwidth 26 dB
Bandwidth Emission Power
MHz kHz kHz
FM
12.5kHz
435 10.120 10.421 High power level
435 10.120 10.421 LowPower Level
25kHz 435 15.281 16.283 High power level
435 15.281 16.283 LowPower Level
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 17 of 48
Occupied Bandwidth –12.5kHz, 435 MHz, High Power Level
Occupied Bandwidth –12.5kHz, 435 MHz, Low Power Level
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 18 of 48
Occupied Bandwidth –25kHz, 435 MHz, High Power Level
Occupied Bandwidth –25kHz, 435 MHz, Low Power Level
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 19 of 48
FCC §2.1051& §97.307 - SPURIOUS EMISSIONS AT ANTENNA TERMINALS Applicable Standard
(a) No amateur station transmission shall occupy more bandwidth than necessary for the information rate and emission type being transmitted, in accordance with good amateur practice.
(b) Emissions resulting from modulation must be confined to the band or segment available to the control operator. Emissions outside the necessary bandwidth must not cause splatter or keyclick interference to operations on adjacent frequencies.
(c) All spurious emissions from a station transmitter must be reduced to the greatest extent practicable. If any spurious emission, including chassis or power line radiation, causes harmful interference to the reception of another radio station, the licensee of the interfering amateur station is required to take steps to eliminate the interference, in accordance with good engineering practice.
(d) For transmitters installed after January 1, 2003, the mean power of any spurious emission from a station transmitter or external RF power amplifier transmitting on a frequency below 30 MHz must be at least 43 dB below the mean power of the fundamental emission. For transmitters installed on or before January 1, 2003, the mean power of any spurious emission from a station transmitter or external RF power amplifier transmitting on a frequency below 30 MHz must not exceed 50 mW and must be at least 40 dB below the mean power of the fundamental emission. For a transmitter of mean power less than 5 W installed on or before January 1, 2003, the attenuation must be at least 30 dB. A transmitter built before April 15, 1977, or first marketed before January 1, 1978, is exempt from this requirement.
(e) The mean power of any spurious emission from a station transmitter or external RF power amplifier transmitting on a frequency between 30-225 MHz must be at least 60 dB below the mean power of the fundamental. For a transmitter having a mean power of 25 W or less, the mean power of any spurious emission supplied to the antenna transmission line must not exceed 25 µW and must be at least 40 dB below the mean power of the fundamental emission, but need not be reduced below the power of 10 µW. A transmitter built before April 15, 1977, or first marketed before January 1, 1978, is exempt from this requirement.
Test Equipment List and Details
Manufacturer Description Model Serial
Number Calibration
Date Calibration Due Date
Rohde & Schwarz Signal Analyzer FSIQ26 831929/005 2017-08-31 2018-08-31
Unknown Coaxial Cable C-SJ00-0010 C0010/01 Each time N/A
HP RF Communications Test Set
8920A 00 235 2017-07-11 2018-07-11
E-Microwave Blocking Control EMDCB-
00036 0E01201047 2018-05-06 2019-05-06
* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI).
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 20 of 48
Test Procedure Adjust the spectrum analyzer for the following settings: 1) Resolution Bandwidth = 100 kHz for spurious emissions below 1 GHz, and 1 MHz for spurious
emissions above 1 GHz. 2) Video Bandwidth ≥3 times the resolution bandwidth. 3) Sweep Speed ≤2000 Hz per second. 4) Detector Mode = mean or average power. Test Data
Environmental Conditions
Temperature: 27.7 C
Relative Humidity: 38 %
ATM Pressure: 101.3 kPa
The testing was performed by Andy Huang on 2018-06-13.
Note: For conducted spurious emissions were tested at high rated power, which was the worst case.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 21 of 48
435MHz – FM Mode, 12.5 kHz
Fundamental with high pass filter
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 22 of 48
435MHz – FM Mode, 25 kHz
Fundamental with high pass filter
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 23 of 48
FCC §2.1053 & §97.307 - RADIATED SPURIOUS EMISSIONS Applicable Standard FCC §2.1053 &§97.307 Test Equipment List and Details
Manufacturer Description Model Serial NumberCalibration
Date Calibration Due Date
R&S EMI Test Receiver ESCI 100224 2017-12-11 2018-12-11
Sunol Sciences Antenna JB3 A060611-1 2017-11-10 2020-11-10
EMCO Adjustable Dipole
Antenna 3121C 9109-753 N/A N/A
Unknown Coaxial Cable C-NJNJ-50 C-0400-01 2017-09-05 2018-09-05
Unknown Coaxial Cable C-NJNJ-50 C-0075-01 2017-09-05 2018-09-05
Unknown Coaxial Cable C-NJNJ-50 C-1000-01 2017-09-05 2018-09-05
Unknown Coaxial Cable C-NJNJ-50 C-0200-02 2017-09-05 2018-09-05
HP Amplifier 8447D 2727A05902 2017-09-05 2018-09-05
Agilent Signal Generator E8247C MY43321350 2017-12-11 2018-12-11
Agilent Spectrum Analyzer E4440A SG43360054 2018-01-04 2019-01-04
Farad Test Software EZ-EMC V1.1.4.2 N/A N/A
TDK RF Horn Antenna HRN-0118 130 084 2016-01-05 2019-01-04
ETS-Lindgren Horn Antenna 3115 000 527 35 2016-01-05 2019-01-04
Unknown Coaxial Cable C-SJSJ-50 C-0800-01 2017-09-05 2018-09-05
MITEQ Amplifier AFS42-
00101800-25-S-42
2001271 2017-09-05 2018-09-05
Agilent Signal Generator E8247C MY43321350 2017-12-11 2018-12-11
* Statement of Traceability: Bay Area Compliant Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI).
Test Procedure The transmitter was placed on a wooden turntable, and it was transmitting into a non-radiating load, which was also placed on the turntable. The measurement antenna was placed at a distance of 3 meters from the EUT. During the tests, the antenna height and polarization as well as EUT azimuth were varied in order to identify the maximum level of emissions from the EUT .The test was performed by placing the EUT on 3-orthogonal axis. The frequency range up to tenth harmonic of the fundamental frequency was investigated. Remove the EUT and replace it with substitution antenna. A signal generator was connected to the substitution antenna by a non-radiating cable. The absolute levels of the spurious emissions were measured by the substitution.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 24 of 48
Test Data
Environmental Conditions
Temperature: 27.7C
Relative Humidity: 38%
ATM Pressure: 101.3kPa
The testing was performed by Blake Yang & Vern Shen on 2018-06-13.
Test Mode: Transmitting-High power level is the worst case.
Model:RT29
Frequency (MHz)
Polar (H/V)
Receiver Reading (dBµV)
Substituted Method Absolute
Level (dBm)
Limit (dBm)
Margin (dB)
SubstitutedLevel (dBm)
Antenna Gain
(dBd/dBi)
Cable Loss (dB)
frequency: 435.000 MHz 12.5kHz
870.000 H 52.36 -45.2 0.0 1 -46.2 -16.0 30.2
870.000 V 52.56 -47.6 0.0 1 -48.6 -16.0 32.6
1305.000 H 53.58 -49.4 9.2 1.1 -41.3 -16.0 25.3
1305.000 V 53.26 -50 9.2 1.1 -41.9 -16.0 25.9
1740.000 H 56.83 -47.5 10.7 1.2 -38.0 -16.0 22.0
1740.000 V 54.18 -50.1 10.7 1.2 -40.6 -16.0 24.6
2175.000 H 58.89 -44.7 11.7 1.2 -34.2 -16.0 18.2
2175.000 V 53.42 -50.6 11.7 1.2 -40.1 -16.0 24.1
2610.000 H 50.71 -51.9 12.2 1.3 -41.0 -16.0 25.0
2610.000 V 48.65 -55 12.2 1.3 -44.1 -16.0 28.1
3045.000 H 47.03 -54.7 12.4 1.5 -43.8 -16.0 27.8
3045.000 V 46.27 -55.3 12.4 1.5 -44.4 -16.0 28.4
frequency: 435.000 MHz 25kHz
870.000 H 52.33 -45.3 0.0 1 -46.3 -16.0 30.3
870.000 V 51.48 -48.6 0.0 1 -49.6 -16.0 33.6
1305.000 H 53.42 -49.6 9.2 1.1 -41.5 -16.0 25.5
1305.000 V 52.85 -50.4 9.2 1.1 -42.3 -16.0 26.3
1740.000 H 57.63 -46.7 10.7 1.2 -37.2 -16.0 21.2
1740.000 V 53.74 -50.5 10.7 1.2 -41.0 -16.0 25.0
2175.000 H 58.63 -45 11.7 1.2 -34.5 -16.0 18.5
2175.000 V 54.24 -49.8 11.7 1.2 -39.3 -16.0 23.3
2610.000 H 50.35 -52.2 12.2 1.3 -41.3 -16.0 25.3
2610.000 V 47.86 -55.8 12.2 1.3 -44.9 -16.0 28.9
3045.000 H 47.18 -54.6 12.4 1.5 -43.7 -16.0 27.7
3045.000 V 46.52 -55 12.4 1.5 -44.1 -16.0 28.1
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 25 of 48
Model:RT29S
Frequency (MHz)
Polar (H/V)
Receiver Reading (dBµV)
Substituted Method Absolute
Level (dBm)
Limit (dBm)
Margin (dB)
SubstitutedLevel (dBm)
Antenna Gain
(dBd/dBi)
Cable Loss (dB)
frequency: 435.000 MHz 12.5kHz
870.000 H 49.14 -25.5 0.0 1 -26.5 -16.0 10.5
870.000 V 41.88 -29.6 0.0 1 -30.6 -16.0 14.6
1305.000 H 54.23 -48.8 9.2 1.1 -40.7 -16.0 24.7
1305.000 V 54.22 -49 9.2 1.1 -40.9 -16.0 24.9
1740.000 H 57.11 -47.2 10.7 1.2 -37.7 -16.0 21.7
1740.000 V 53.99 -50.3 10.7 1.2 -40.8 -16.0 24.8
2175.000 H 58.90 -44.7 11.7 1.2 -34.2 -16.0 18.2
2175.000 V 53.40 -50.7 11.7 1.2 -40.2 -16.0 24.2
2610.000 H 49.98 -52.6 12.2 1.3 -41.7 -16.0 25.7
2610.000 V 49.50 -54.2 12.2 1.3 -43.3 -16.0 27.3
3045.000 H 47.00 -54.8 12.4 1.5 -43.9 -16.0 27.9
3045.000 V 46.11 -55.4 12.4 1.5 -44.5 -16.0 28.5
frequency: 435.000 MHz 25kHz
870.000 H 50.12 -24.5 0.0 1 -25.5 -16.0 9.5
870.000 V 42.01 -29.4 0.0 1 -30.4 -16.0 14.4
1305.000 H 53.50 -49.5 9.2 1.1 -41.4 -16.0 25.4
1305.000 V 52.80 -50.5 9.2 1.1 -42.4 -16.0 26.4
1740.000 H 57.58 -46.7 10.7 1.2 -37.2 -16.0 21.2
1740.000 V 53.95 -50.3 10.7 1.2 -40.8 -16.0 24.8
2175.000 H 59.14 -44.5 11.7 1.2 -34.0 -16.0 18.0
2175.000 V 54.10 -50 11.7 1.2 -39.5 -16.0 23.5
2610.000 H 50.56 -52 12.2 1.3 -41.1 -16.0 25.1
2610.000 V 48.00 -55.7 12.2 1.3 -44.8 -16.0 28.8
3045.000 H 47.10 -54.7 12.4 1.5 -43.8 -16.0 27.8
3045.000 V 46.20 -55.3 12.4 1.5 -44.4 -16.0 28.4
Note1: For radiated spurious emissions were tested at high rated power, which was the worst case. Note2: The unit of Antenna Gain is dBd for frequency below 1GHz, and the unit of Antenna Gain is dBi for frequency above 1GHz. Note3: Absolute Level = SG Level - Cable loss + Antenna Gain Margin = Limit-Absolute Level
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 26 of 48
FCC §2.1055 - FREQUENCY STABILITY Applicable Standard FCC §2.1055, Test Equipment List and Details
Manufacturer Description Model No. Serial No. Calibration
Date Calibration Due Date
Rohde & Schwarz Signal Analyzer FSIQ26 831929/005 2017-08-31 2018-08-31
Unknown Coaxial Cable C-SJ00-0010 C0010/01 Each time N/A
E-Microwave Blocking Control EMDCB-00036 0E01201047 2018-05-06 2019-05-06
E-Microwave Coaxial Attenuators EMCA40-200SN-6
OE01201046 2017-09-05 2018-09-05
HP RF Communications Test Set 8920A 00 235 2017-07-11 2018-07-11
Dongzhixu High Temperature Test Chamber
DP1000 201105083-4 2017-08-28 2018-08-28
UNI-T Multimeter UT39A M130199938 2018-05-09 2019-05-09
* Statement of Traceability: Bay Area Compliant Laboratories Corp. (Dongguan) attests that all calibrations have been performed, traceable to National Primary Standards and International System of Units (SI).
Test Procedure Frequency Stability vs. Temperature: The equipment under test was connected to DC power supply and the RF output was connected to a frequency counter via feed-through attenuators. The EUT was placed inside the temperature chamber. The power leads and RF output cable exited the chamber through an opening made for the purpose. After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the counter. The frequency stability shall be measured with variation of primary supply voltage as follows: (1) For hand carried, battery powered equipment, reduce primary supply voltage to the battery operating end point
which shall be specified by the manufacturer.
Test Data
Environmental Conditions
Temperature: 24.5C
Relative Humidity: 56 %
ATM Pressure: 101.4 kPa
The testing was performed by Andy Huang on 2018-03-01.
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 27 of 48
Test Mode: Transmitting
Reference Frequency: 435 MHz, 12.5 kHz
Temerature Voltage Reading Frequency Error
℃ VDC MHz ppm
-30
7.4
435.000230 0.53
-20 435.000175 0.40
-10 435.000165 0.38
0 435.000198 0.46
10 435.000170 0.39
20 435.000190 0.44
30 435.000208 0.48
40 435.000210 0.48
50 435.000157 0.36
60 435.000212 0.49
25 8.4 435.000250 0.57
25 7 435.000230 0.53
Reference Frequency: 435 MHz, 25 kHz
Temerature Voltage Reading Frequency Error
℃ VDC MHz ppm
-30
7.4
435.000160 0.37
-20 435.000193 0.44
-10 435.000145 0.33
0 435.000198 0.46
10 435.000220 0.51
20 435.000210 0.48
30 435.000201 0.46
40 435.000240 0.55
50 435.000177 0.41
60 435.000208 0.48
25 8.4 435.000240 0.55
25 7 435.000226 0.52
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 28 of 48
EXHIBIT A - EUT EXTERNAL PHOTOGRAPHS
EUT – All View
EUT – Adapter Top View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 29 of 48
EUT – Adapter Label View
Model:RT29S
EUT – Top View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 30 of 48
EUT – Bottom View
EUT – Side View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 31 of 48
EUT –Side View
EUT –Side View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 32 of 48
EUT – Side View
EUT –Port View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 33 of 48
Model:RT29
EUT – Top View
EUT – Bottom View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 34 of 48
EUT – Side View
EUT –Side View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 35 of 48
EUT –Side View
EUT –Side View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 36 of 48
EUT – Uncover View
EUT – Battery Top View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 37 of 48
EUT – Battery Bottom View
EUT – Battery Label View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 38 of 48
EUT – Port View
EUT –Uncover-1 View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 39 of 48
EUT – Uncover 2 View
EUT – Uncover 3 View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 40 of 48
EUT – Main Board Top View
EUT – Main Board Bottom View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 41 of 48
EUT – RF Chip View
EUT – Charging Base Top View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 42 of 48
EUT – Charging Base Bottom View
EUT – Uncover View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 43 of 48
EUT – Uncover View
EUT – Subboard Top View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 44 of 48
EUT – Subboard Bottom View
EUT – Antenna View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 45 of 48
EUT – Antenna Port View
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 46 of 48
EXHIBIT B - TEST SETUP PHOTOGRAPHS
Radiated Emissions View (Below 1GHz)-RT29
Radiated Emission View (Above 1 GHz)-RT29
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 47 of 48
Radiated Emissions View (Below 1GHz)-RT29S
Radiated Emission View (Above 1 GHz)-RT29S
Bay Area Compliant Laboratories Corp. (Dongguan) Report No.: RXM180727055-00A1
Page 48 of 48
EXHIBIT C – DECLARATION LETTER