Upload
doannhi
View
219
Download
2
Embed Size (px)
Citation preview
RoHS
2 mounting types
High speed response
Series SX10 CAT.ES70-53A
ON: 0.45 ms
ONOFF
50 L/min 80 W type
OFF: 0.4 ms
High speed response
50 L/min 80 W typeSwitching frequency: 1200 Hz
High frequency: 1200 HzGood followability and response to successive electrical signal input. Continuous operation possible.
Long service life: 5 billion cycles or moreSMC’s original valve and coil structure realizes a longer product life and requires less maintenance frequency.(50 L/min type, 24 VDC, 0.25 MPa. Based on SMC life test conditions.)
Low power consumption: 4 WContinuous energization for extended periods is possible.
0.4 ms±0.05 ms0.45 ms
±0.05 msOFF
ON
High speed response
The manifold base should be prepared by users.
* The response time is measured based on SMC test conditions. (Not guaranteed values)
Screw mount typeQuick disconnect type
High Speed 2 Port Valve
9mmWidth
Compact and Space-saving
Variations/Purpose of Usage (Guide)
9.5 mm
9 mm
30.4 mm
* The manifold base should be prepared by users.
(Screw mount type)
Manifold minimum mounting pitch
Specifications DriverContinuous energization
Power consumption
OFF response time
50 L/min 100 L/min 150 L/min
q Ultra high frequency type 500 to 1200 Hz For power saving driver (Refer to page 4.) — 80 W, 40 W 0.4 ms 0.55 ms 0.75 ms
w High frequency type 250 to 550 Hz Control driver is not necessary. (Note) 10 W 0.4 ms 0.55 ms 0.75 ms
e Super energy-saving type 150 to 350 Hz Control driver is not necessary. Possible 4 W 0.4 ms 0.55 ms 0.75 ms
Flow Rate/Operating Frequency
(Note) Please consult with SMC for continuous energization.
150
100
50
150 250 350 400 500 550 650 1200 (Hz)(L/min)
Operating frequency
Flo
w r
ate
Super energy-saving type Ultra high frequency type
High frequency type
3 1
2High flow
Medium flow
Low flow
(Supply pressure 0.25 MPa, 24 VDC, Duty ratio 1:1)
Series SX10
Width
Height
Coil temperature rise: 5°C(4 W type)
Filter attachedtype available
Reduction in installation labor(Quick disconnect type)
Can be mounted/removed in one action and no tools required.
Filter is mounted to port 1 (IN) for quick disconnect type as well.
Filter is mounted to port 1 (IN).
Power consumption Temperature rise
4 W type 5°C
10 W type 14°CDuring continuous operation at 24 VDC, 0.25 MPa, 300 Hz
Required time forattachment/detachment:Approx. 5 seconds(per unit)
Reduces installation time for multiple numbers of valves.
Actualsize
Actualsize
Features 1
Select a model according to applications and purposes.
High Speed 2 Port Valve
Select the
4 Wtype.
High speed response required for both ON and OFF
High speed response required for OFF only without use of special control circuit
Saving energy and continuous energization required
ModelPower
consumptionFlow rate
Max. operating frequency
Response time (ms)
ON OFF
SX1 -A 80 W 50 L/min 1200 Hz 0.45 0.4
-B 40 W 50 L/min 1000 Hz 0.55 0.4
-E 80 W 100 L/min 650 Hz 0.55 0.55
-F 40 W 100 L/min 550 Hz 0.7 0.55
-J 80 W 150 L/min 600 Hz 0.6 0.75
-K 40 W 150 L/min 500 Hz 0.8 0.75
* Current needs to be limited.
ModelPower
consumptionFlow rate
Max. operating frequency
Response time (ms)
ON OFF
SX1 -C 10 W 50 L/min 550 Hz 0.9 0.4
-G 10 W 100 L/min 300 Hz 1.1 0.55
-L 10 W 150 L/min 250 Hz 1.35 0.75
ModelPower
consumptionFlow rate
Max. operating frequency
Response time (ms)
ON OFF
SX1 -D 4 W 50 L/min 350 Hz 1.25 0.4
-H 4 W 100 L/min 200 Hz 1.7 0.55
-M 4 W 150 L/min 150 Hz 2.75 0.75
* Please consult with SMC for continuous energization.
* Continuous energization is possible.
Select the
80 W or 40 Wtype.
Select the
10 Wtype.
VariationsAll models have the same body size.
Flow rate Powerconsumption Operating frequency100 Hz 500 Hz 1000 Hz
80 W
40 W
10 W
4 W
80 W
40 W
10 W
4 W
80 W
40 W
10 W
4 W
650 Hz
550 Hz
300 Hz
200 Hz
600 Hz
500 Hz
250 Hz
150 Hz
Lowflow type
50 L/min
Mediumflow type
100 L/min
Highflow type
150 L/min
1200 Hz
1000 Hz
550 Hz
350 Hz
Features 2
Flow rate/Operating frequency (at 24 VDC, 0.25 MPa)Symbol Flow rate (L/min) Power consumption (W) Max. operating frequency (Hz)
A
50
80 1200B 40 1000C 10 550D 4 350E
100
80 650F 40 550G 10 300H 4 200J
150
80 600K 40 500L 10 250M 4 150
Valve mounting1 Screw mount type Note)
2 Quick disconnect type
Note) Two mounting screws (M3 x 0.5) and a gasket are included.(packaged together)
Filter (IN port)Nil Without filter F With filter Note)
Note) Flow reduction rate 50 L/min: 5% or less100 L/min: 5 to 10%150 L/min: 10 to 15%
2 FSX1 A GLead wire (grommet) length
Symbol LengthG 300 mmH 500 mmJ 1000 mm
Characteristics
Flow rate (L/min) [at 0.25 MPa] 50 100 150Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4
Flow-rate characteristics
C [dm3/(s/bar)] 0.24 0.47 0.70b 0.24 0.28 0.21
Cv 0.06 0.12 0.17Response time (ms)[at 0.25 MPa]
ON 0.45 0.55 0.9 1.25 0.55 0.7 1.1 1.7 0.6 0.8 1.35 2.75OFF 0.4 0.4 0.4 0.4 0.55 0.55 0.55 0.55 0.75 0.75 0.75 0.75
Max. operating frequency (Hz) [at 0.25 MPa] 1,200 1,000 550 350 650 550 300 200 600 500 250 150
Note 1) 24 VDC, Duty ratio 1:180 W: Current needs to be limited by using an energy saving driver circuit.40 W: Current needs to be limited by using an energy saving driver circuit.10 W: Energizing time is one second at a maximum. Please consult with SMC for
continuous energization. 4 W: Continuous energization is possible.
Note 2) The response time and maximum operating frequency are not guaranteed. (Actual values based on SMC test conditions)
Pressure/Flow-rate Characteristics (without filter)
Specifications
Flow rate (L/min) [at 0.25 MPa] 50 100 150Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4Type of actuation 2-position 2 port N.C., Air returnSeal type Metal poppet sealValve width (mm) 9Fluid AirMin. operating pressure (MPa) 0.15Coil resistance value (Ω) 7.2 14.4 58 144 7.2 14.4 58 144 7.2 14.4 58 144Max. operating pressure (MPa) [at 24 VDC] 0.7 0.7 0.7 0.6 0.7 0.7 0.6 0.4 0.7 0.7 0.4 0.25Ambient and fluid temperature (°C) −10 to 50 (No freezing)Lubrication Not requiredMounting orientation UnrestrictedImpact/Vibration resistance (m/s2) 300/50Enclosure DustproofElectrical entry Grommet
Weight (g)Screw mount type 27Quick disconnect type 29
0 0.80.70.60.50.4Pressure (MPa)
Flo
w r
ate
(L/m
in)
0.30.20.1
380360340320300280260240220200180160140120100
80604020
0
Flow rate 150 L/min type
Flow rate 100 L/min type
Flow rate 50 L/min type
How to Order
High Speed 2 Port Valve
Series SX10
1
RoHS
Dimensions
SX12-G Quick disconnect type
Manifold base recommended dimensions
36.9
3.8
34.9 Approx. 300(Lead wire length)
0.9
9
45
40
19 9
ø6.9ø6.9
1.5
1.5
2.7
5.9
17.7
1 (IN) port2 (OUT) port
2
RZ
12.5RZ
12.5
Sectional view A-A (2:1)
C or R0.3
C or R
0.3
Base mounting hole
2 (OUT) port
9.5
or m
ore
Val
ve m
ount
ing
pitc
h
2.4
5 or
mor
e
39.5±0.2
3 or more
1 (IN) port
3 or more
9±0.05 11.8±0.1
C0.5C0.5
ø7.1±0.05
Depth 4 or moreø7.1±0.05
Depth 4 or more
AA2 (OUT) port
2 (OUT) 1 (IN)
1 (IN) port
2
High Speed 2 Port Valve Series SX10
Dimensions
SX11-G Screw mount type
Manifold base recommended dimensions
Electrical entry can be on the either side, right or left.
Sectional view A-A (2:1)
A A
40
31111
M3 x 0.5 Thread depth 5
3
M3 x 0.5 Thread depth 5
2 (OUT) port
Base mounting hole
1 (IN) port
ø46 or more
9.5
or m
ore
Val
ve m
ount
ing
pitc
h
ø4 ø4
2 x ø3.2Mounting hole
3
40
34.9 Approx. 300(Lead wire length)
M3 x 0.5 Mounting screw(Included)
Gasket(Included)
0.9
9
30.4
(4)
6
46
23.9
11.8
92 (OUT) port
5.4
1 (IN) port Operates by supplying pressure to either side.
6
2 (OUT) port 1 (IN) port
2 (OUT)
2 (OUT)
1 (IN)
1 (IN)
Lead wire
Lead wire
3
Series SX10
Control Method (Operation example with an energy saving driver circuit)
1. Control with 2 power supplies, starting power supply and holding power supply.Switching system from high voltage to low voltage
2. High speed switching control of high voltage by PWM control*. (*: PWM control circuit not currently available.)
SW1Valve
SW2
SW1
SW2
OFF
OFF
ON
ON
Voltagebetween terminals OFF
24 VDC(Note)
High-voltage power supply(24 VDC)
Low-voltage power supply(Note)
SW1Valve
SW1OFF
ON
Averagevoltage
OFF
24 VDC(Note)
High-voltage power supply(24 VDC)
Specific Product PrecautionsBe sure to read before handling. Refer to back cover for Safety Instructions. For 2 Port Solenoid Valves for Fluid Control Precautions, refer to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com
Continuous Energization (at 24 VDC)
Caution1. Power consumption 80 W type: Not available
When operating with an energy saving driver, continuous energization with the holding voltage of 3 to 6 VDC is possible.
2. Power consumption 40 W type: Not availableWhen operating with an energy saving driver, continuous energization with the holding voltage of 4 to 8 VDC is possible.
3. Power consumption 10 W type: Please consult with SMC.When operating with an energy saving driver, continuous energization with the holding voltage of 8 to 16 VDC is possible.
4. Power consumption 4 W type: Available
Energized Time/Non-energized Time(When not using power saving driver)
Caution1. Non-energized time (OFF) must be set longer than
the energized time (ON).
2. For use with voltages other than 24 VDC, please consult with SMC with the operating condition information of pressure, voltage, energized time and non-energized time.
Others
Caution1. If the valve is energized without air supply, the coil
may be burned. Make sure to supply pressure to the valve when energizing.
2. Please contact SMC for the product usage with a voltage at 75 VDC or more. Standard required by CE mark is different.
(Note) 80 W type: 3 to 6 VDC 40 W type: 4 to 8 VDC 10 W type: 8 to 16 VDC
4
High Speed 2 Port Valve Series SX10
1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment.The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.1. The inspection and maintenance of machinery/equipment should only be
performed after measures to prevent falling or runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use
outdoors or in a place exposed to direct sunlight.2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
Warning
Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”.Read and accept them before using the product.
1. The product is provided for use in manufacturing industries.The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Caution
Limited warranty and Disclaimer1. The warranty period of the product is 1 year in service or 1.5 years after
the product is delivered, whichever is first.∗2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products.
∗2) Vacuum pads are excluded from this 1 year warranty.A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.
Compliance Requirements1. The use of SMC products with production equipment for the manufacture of
weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.
These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems. ISO 4413: Hydraulic fluid power – General rules relating to systems. IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Manipulating industrial robots – Safety. etc.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
Caution:
Warning:
Danger :Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Safety Instructions
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.