Upload
truonganh
View
273
Download
5
Embed Size (px)
Citation preview
REYROLLE
THE RELAY SPECIALISTS
relay monitoring systems pty ltd www.rmpl.com.au
RMS Product Presentation
REYROLLE
Relay Monitoring Systems Pty Ltd6 Anzed Court - Melbourne - Australia
REYROLLE
Manufacturing in Australia
REYROLLE
Company History
RPL Established 1955
EMAIL Take Over 1970
RMS Take Over 1991
Product references with major power utilities in Australia
Exports to UK, South Africa, Malaysia, Korea, Middle East,India, Thailand, Hong Kong, Pakistan, Indonesia +
Marketing agreement with Reyrolle Protection & Mors Smitt
REYROLLE
International Quality AccreditationAS/NZS ISO9001:2008
REYROLLE
Product Range Overview
REYROLLE
Test Blocks and Plugs
RMS 4M3004M300 Test Block14 way with or without DC isolation2M28-S case
APPLICATIONFront of panel testing for protection circuitsFront of panel testing for metering circuits
RMS 4M320Test Plug with 4mm safety socketsInsertion handles
REYROLLE
Test Plugs
RMS 2RMLB4M400 Test BlockCompatible with Areva MMLBCompatible with Reyrolle 2RMLB
APPLICATIONFront of panel testing for protection circuitsFront of panel testing for metering circuits
REYROLLE
Circuit Breaker Control
1X50 CB Trip & Close Module
Large size push buttonsHigh visibility CB status LED’sSuitable for 24, 32, 48, 110/125 & 240/250VdcOptional CB spring charge status LEDOptional locking coverOptional arc suppression circuitryOptional lamp test button & output contactOptional integrated control circuit steering diodesOptional custom engraving 4U rack or flush mounting2M28-S case
APPLICATIONProvide independent breaker controlUse with Reyrolle Argus-M
REYROLLE
Arc Fault Protection
1S20 Arc Fault Monitor – 2 Zone & 3 Sensors
APPLICATIONAir insulated metal clad switchgear Panel mount or DIN rail mount versionsLow cost, can be used on per panel basis
1S20
1S30
1S30
1S30
50/51
Trip BUS CB(s)
1S20
1S30
1S30
1S30
50/51
Trip BUS CB(s)
REYROLLE
Arc Fault Protection
1S25 Arc Fault Monitor – 4 Zone & 8 Sensors
1S25
HEALTHY
ZONE 2
ZONE 3
ZONE 4
ZONE 1
Cus tom text
Cus tom text
Cus tom text
Cus tom text
FAIL
FAIL
FAIL
FAIL
TRIP
TRIP
TRIP
TRIP
RESET/TEST
COMMON TRIPALARM
OUTPUTS
REYROLLE
Arc Fault Protection
1S26 Arc Fault Monitor with Current Check – 4 Zone & 8 Sensors
REYROLLE
Alarm Annunciator
1A54 Alarm Panel – 4, 8 & 16 point versions & up to 6 contacts per point
Repeat output contacts (latching or self reset)Acknowledge & ResetNon volatile memoryUniversal binary input voltageConfiguration code / switches 2M28-S case4M56-S case
APPLICATIONTransformer alarmsStation alarmsAnnunciators
REYROLLE
Busbar Protection Relay
RMS 2V73High Impedance Differential (87B)Voltage operated2M28-S caseEquivalent to Areva MFAC
APPLICATIONBus zone differentialMachine differentialRestricted earth fault
See 2V75 for metrosil & resistors
REYROLLE
Busbar Protection Relay
RMS 2C73High Impedance Differential (87B)Current operated2M28-S caseEquivalent to Areva MCAG
APPLICATIONBus zone differentialMachine differentialRestricted earth fault
See 2V75 for metrosil & resistors
REYROLLE
High Impedance Differential Relay
RMS 2C75-SHigh Impedance Differential Protection (87)Current Operated Fast Operate Speed (< 25msec)CT Supervision (50)CT Shorting OutputCT Supervision Differential Block LogicUSB programming portModbus communication protocol 4M56-S case
APPLICATIONMedium and Low Voltage Bus ProtectionStator Winding Differential Protection
See 2V75 for metrosil & resistors
REYROLLE
Metrosil Modules
RMS 2V75Metrosil & Resistor module1 pole or 3 pole3 inch or 6 inch metrosils100W or 200W resistorsFlush, rack or back of panel mount
APPLICATIONHigh impedance differential schemesMetrosil and resistors can be supplied loose
REYROLLE
CT Supervision & Shorting Relay
RMS 2V68CT buswire supervision3s fixed supervision delay3 N/O latched contacts for supervision alarm3 N/O latched contacts for buswire shortingHand reset flag4M28 case
APPLICATIONHigh impedance differential schemes
REYROLLE
High Impedance Differential Schemes
RMS 1M123Electromechanical design 2V73 or 2C73 – 3x high impedance relays2V75 – metrosil & resistor module2HSM – trip relay4M800K1 – 4U high 19” rack frame
APPLICATIONBus zone differentialMachine differential
REYROLLE
Voltage Regulation Relay
RMS 2V164-SuMATRIX digital platformUSB programming portFine & Coarse voltage bandwidthsUndervoltage blockingOvervoltage alarmOvercurrent blockingLine drop compensationTap position indication (TPI) when using 2V200Optional Modbus communication protocolOptional analog outputs mA
APPLICATIONOLTC control
REYROLLE
Parallel Control System
RMS 1M122AMaster follower parallel control scheme2V164 - voltage regulation relay2V165 - parallel control relay1X200 - control module2V200 - tap position transducer4M800K1 - 19” sub rack
APPLICATIONOLTC parallel control for up to 4 transformers
REYROLLE
TPI Transducer & Indicator
RMS 2V200Tap position transducerResistor chain or BCD inputs0 to 5kHz outputFor use with 2V164 or 4D200
RMS 4D200Tap position indicatorFor use with 2V200Optional BCD inputsOptional BCD outputsExternal 12Vdc supply required
APPLICATIONOLTC position indication
REYROLLE
TPI Selector Switch
RMS 4M900Up to 22 tap positionsGold plated contact switchesOne or Two TPI switch gangsCustom mechanical coupling
APPLICATIONReplace worn tap position contacts to provide
reliable tap position indication to SCADA
REYROLLE
Frequency Relay
RMS 2H34-SuMATRIX digital platformUSB programming port4 stage frequency (81)4 stage rate of change frequency df/dt (81R)Undervoltage blockingModbus communication protocol 4M56-S case
APPLICATIONLoad sheddingGenerator control
REYROLLE
Synchronism Check Relay
RMS 2SY212-SSynchronism Check (25)Adjustable phase angle and time delayFlexible Live and Dead Voltage configurationBus or Line U/V Close BlockVoltage Differential Close BlockFrequency Slip Close BlockFlexible Synchronism Check Bypass LogicManual Safe to Close FeatureUSB programming port Modbus communication protocol 4M56-S case
APPLICATIONSSafe CB Closure in Generator InstallationsSub-transmission and Distribution AutoReclose SchemesCogeneration ApplicationsAnti Islanding Schemes
REYROLLE
Voltage Relay
RMS 2V67-SuMATRIX digital platformUSB programming port1 or 3 phase4 stage under/over voltage (27/59)Undervoltage blockingModbus communication protocol 4M56-S case
APPLICATIONBus voltage supervisionOLTC supervisionGenerator control
REYROLLE
Auto Reclose
RMS 1B2301 or 2 shot (79)Adjustable dead timers and reclaim timerOptional reclose counterShunt initiate inputOptional series initiate inputCB auxiliary switch inputLine voltage interlock inputCB spring charged inputSafe to close inputDrive to lockout inputRemote reset input
APPLICATIONOverhead linesRetrofits
REYROLLE
DC Intertrip & Supervision
RMS 3A300DC Intertrip & Pilot SupervisonInherent 5kV or 15kV pilot wire isolationUp to 4 ends / stationsContinuous or pulse mode pilot supervisionCompatible with GCM05 in continuous modeTrip supply supervisionFlush or rack mount Size 6 or 8 case
APPLICATIONTransformer ended feedersTeed feedersMesh networks
REYROLLE
Solkor DC Supervision Scheme
RMS 3A400DC Pilot SupervisionInherent 5kV or 15kV pilot wire isolationContinuous or pulse mode pilot supervisionFlush or rack mount Size 6 or 8 case
APPLICATIONSupervision of Solkor protection schemes
REYROLLE
Trip Relays
RMS 2HSM (6RJ)Attracted armature relays (6R Matrix)High speed tripping < 10ms Up to 20 contacts2M28-S, 4M28-S, 4M56-S caseEquivalents to Areva MVAJ
APPLICATIONCB trip relayLockout relayBus zone trip relayCB fail trip relay
REYROLLE
Auxiliary Flag Relays
RMS 6RM (6RA)Attracted armature relays (6R Matrix)Auxiliary speed < 40ms 1 or 2 element versions3 or 4 element versions also available2M28-S, 4M28-S, 4M56-S caseEquivalents to Areva MVAA
APPLICATIONFlag relaysRepeat relays
REYROLLE
Trip Circuit Supervision Relays
RMS 1TM (6RX)Atttracted armature relays (6R Matrix)Delay on drop-off2M28-S, 4M28-S caseEquivalents to Areva MVAX
APPLICATIONTrip supply supervisionTrip circuit supervision Trip relay supervision
REYROLLE
New RMS Product
Alpha-12 Auxiliary & Tripping Relays
REYROLLE
Active Burden ModuleImprove security of low burden, high speed
solid state status inputs
ABM-48Provides capacitor discharge protectionESI-48-4 co mplianceTransient noise withstand to IEC60255Compact & easy to fitLow average operating burden15ms fixed operate timeWide voltage operating rangeThermal cut out protectionOperation check LED
REYROLLE
Trip Circuit Supervision Relays
RMS 1X10Fuse supervision relay (96)
RMS 1X20Trip supply supervision (96)Trip circuit supervision relay with CB closed (74)Delay on drop off
RMS 1X30Trip circuit supervision relay with CB open or CB closed (74)Delay on drop off
REYROLLE
Voltage Selection Relay
RMS 2P48Phase failure, Phase unbalance, UndervoltageLED incoming and outgoing supply indication5 C/O contactsDelay on drop off (optional)4M28-S case
APPLICATIONVoltage changeover scheme (60)
REYROLLE
Phase Failure Relay
RMS 2P49Phase failure, Phase unbalance, UndervoltageRack or Panel Mount2 C/O contacts
RMS 2P740Phase failure, Phase unbalance, UndervoltageDIN rail mount2 C/O contacts
TERMINATION
Contact 1
Contact 2
2
1
3
4
5
6
7
8
9
12
11
10
PHASEFAILURE RELAY
2P740
SUPPLY NORMAL
SENSITIVITYUnbalanced Voltage
15% 5%
415V 3 Phase 50Hz
REYROLLE
Sensitive Earth Fault Relay
RMS 2C138Upgraded version of 2C137Improved harmonic rejection characterisitcNon volatile trip LED indicationUniversal binary input voltage Surface mount PCB designSelectable reset characteristic in same modelConfiguration code / switches 2M28-S case
APPLICATIONFeeder SEFMaster SEF to enable Feeder SEFBackup SEFStandby SEF
REYROLLE
Current Check Relay
RMS 2C65Upgraded version of 2C63 & 2C64Non volatile trip LED indicationUniversal binary input voltage8 C/O contacts3 phase and phase segregated in same model Surface mount PCB design< 15ms pickup / dropoutConfiguration code / switches 4M56-S case
APPLICATIONCB failDefinite time overcurrentInstantaneous overcurrentCurrent guard
REYROLLE
Digital Time Delay Relay
RMS 2T105Upgraded version of 2T1040-0.99s, 0-9.9s, 0-99s, 0-990sTime delay operate or release in same model4 C/O contactsNon volatile trip LED indicationUniversal binary input voltage Surface mount PCB designConfiguration code / switches 2M28-S case
APPLICATIONCB fail timerCB auxiliary switch CB failVoltage changeover schemesDefinite time delaysReset delays
REYROLLE
Battery Earth Fault Relays
RMS 2L10 / 2L11Attracted armature relays (6R Matrix)High sensitivityDouble wound coils operate in series oppositionEarth fault (2L10)Positive & negative earth fault (2L11)2M28-S, 4M28-S case
APPLICATIONSubstation DC battery banks
REYROLLE
Voltage Relay
RMS 2V76Upgraded version of 2V74Single phase voltageSelectable under or over voltageNon volatile trip LED indicationUniversal binary input voltage5 C/O contactsSurface mount PCB designConfiguration code / switches 2M28-S case
APPLICATIONVoltage changeover scheme (60)1 stage under or over voltage relay (27, 59)1 stage neutral displacement (59N)
REYROLLE
DC Current Sensing Relay
RMS 2C81Shunt operated (mV input range)Instantaneous or time delayed2 C/O output contacts2M28-S case
APPLICATIONDC overcurrent
REYROLLE
Modular Monitoring Relays
RMS 700 SERIES2C720 AC Current 1F701 Flasher2H750 Frequency2H760 Frequency1L710 Liquid Level2P740 Phase Failure2T749 Delay Operate Timer2T751 Delay Release Timer2T770 Recycling Timer2TD770 Thermistor2V730 AC Voltage2V731 DC Voltage3Y701 AuxiliaryHN0118001B Din Rail Clip
TERMINATION
Contact 1
Contact 2
2
1
3
4
5
6
7
8
9
12
11
10
PHASEFAILURE RELAY
2P740
SUPPLY NORMAL
SENSITIVITYUnbalanced Voltage
15% 5%
415V 3 Phase 50Hz
REYROLLE
Protection Schemes
Example: 1S28 Arc Fault Monitor System
REYROLLE
Mors Smitt Rail Components
REYROLLE
Mors Smitt Rail Components
On-boardRelays
Measuring Instruments
REYROLLE
Thank You