32
© 2008 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Ring Main Units Xiria 3.6 - 24 kV Alex Pikkert Marketing Product Manager April 2010 version 2.0

Ring Main Units Xiria 3.6 - 24 kV - Eaton

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ring Main Units Xiria 3.6 - 24 kV - Eaton

© 2008 Eaton Corporation. All rights reserved.

This is a photographic template – yourphotograph should fit precisely within this rectangle.

Ring Main UnitsXiria 3.6 - 24 kV

Alex PikkertMarketing Product Manager

April 2010 version 2.0

Page 2: Ring Main Units Xiria 3.6 - 24 kV - Eaton

2 2

Application in the distribution network

Xiria overview

Page 3: Ring Main Units Xiria 3.6 - 24 kV - Eaton

3 3

Application in the distribution network

Xiria overview

Page 4: Ring Main Units Xiria 3.6 - 24 kV - Eaton

4 4

Ring Main Unit switchgear

Page 5: Ring Main Units Xiria 3.6 - 24 kV - Eaton

5 5

Xiria - overview

Vacuum load break switch panel• Connection of ring cables

Vacuum circuit-breaker panel• Protection of cables and

transformers

Electronic protection relay• Optimal protection selectivity• Alternative for fuse protection

Cable connections• Safe insulated cable connections

Page 6: Ring Main Units Xiria 3.6 - 24 kV - Eaton

6 6

Xiria overview

• Any combination of load break switches and circuit-breakers can be placed in a 2- 3- 4- or 5-panel unit.

Page 7: Ring Main Units Xiria 3.6 - 24 kV - Eaton

7 7

Vacuum technology

• Diffuse discharge• Interrupters for:

• Circuit-breaker• Load break switch

Page 8: Ring Main Units Xiria 3.6 - 24 kV - Eaton

8 8

Vacuum technology

• Diffuse discharge principle

Click to start movie

Page 9: Ring Main Units Xiria 3.6 - 24 kV - Eaton

9 9

Features & benefits

Enclosure• Maintenance free• A “sealed for life” steel

enclosure containing all primary parts and the driving mechanisms

• Internal arc proof

Page 10: Ring Main Units Xiria 3.6 - 24 kV - Eaton

10 10

Environment• Air insulated• Vacuum switching

technology• Easy recycling

Features & benefits

Page 11: Ring Main Units Xiria 3.6 - 24 kV - Eaton

11 11

Safety

• Visible position indication vacuum interrupter• Positive interlockings• Integrated visible earthing• Integrated voltage detection• Arc resistant enclosure

Operation position Earthed position

Features & benefits

Page 12: Ring Main Units Xiria 3.6 - 24 kV - Eaton

12 12

Switching sequence

Service position

Page 13: Ring Main Units Xiria 3.6 - 24 kV - Eaton

13 13

Open position

Switching sequence

Page 14: Ring Main Units Xiria 3.6 - 24 kV - Eaton

14 14

Isolated position

Switching sequence

Page 15: Ring Main Units Xiria 3.6 - 24 kV - Eaton

15 15

Earthed position

Switching sequence

Page 16: Ring Main Units Xiria 3.6 - 24 kV - Eaton

16 16

Test position

Switching sequence

Page 17: Ring Main Units Xiria 3.6 - 24 kV - Eaton

17 17

Compact design• Minimal floor space• Low building costs• Easy to install• Two, three, four of five feeders

1305 mm

760 mm (2 panels)1110 mm (3 panels)1460 mm (4 panels)1810 mm (5 panels)

600 mm

Features & benefits

Page 18: Ring Main Units Xiria 3.6 - 24 kV - Eaton

18 18

Remote control• Remote signalling• Remote tripping• Remote control• Computer controlled

relay setting & reading

Features & benefits

Page 19: Ring Main Units Xiria 3.6 - 24 kV - Eaton

19 19

Applications

Energiverkeni Halmstad ABSweden

Page 20: Ring Main Units Xiria 3.6 - 24 kV - Eaton

20 20

Applications

Skövde Elnät ABSweden

Page 21: Ring Main Units Xiria 3.6 - 24 kV - Eaton

21 21

Applications

Lerum Energi ABSweden

Up-to-date pictures Xiria5 slides

Page 22: Ring Main Units Xiria 3.6 - 24 kV - Eaton

22 22

Applications

Solvay Pharmaceutical BV the Netherlands

Page 23: Ring Main Units Xiria 3.6 - 24 kV - Eaton

23 23

Xiria with tariff metering

• 12 and 24 kV tariff metering

• Fits in Alfen Diabolo 20, 30 and 40 stations

• Dutch Regulator Dte Metering codes

• Customer connection up to 5 MVA

• Screened connectors Tyco RSTI

• No cable cellar needed

• Including ferro-resonance filter

• In 3- or 4 or 5 panel unit

Page 24: Ring Main Units Xiria 3.6 - 24 kV - Eaton

24 24

Current transformers for tariff metering

Low voltage fuses and terminals

Protection relay WIC1

24 kV voltage transformers

Current transformers for protection

Xiria-M (max. 24 kV tariff metering)

Page 25: Ring Main Units Xiria 3.6 - 24 kV - Eaton

25 25

Xiria-MA (max. 12 kV tariff metering)

Current transformers for tariff metering

Low voltage fuses and terminals

Protection relay WIC1

12 kV voltage transformers

Current transformers for protection

Page 26: Ring Main Units Xiria 3.6 - 24 kV - Eaton

26 26

Reference listThe Netherlands Gemaal Gorzeman Hellevoetsluis ● Philips Roozendaal ● Essent ● Tetra Pak Moerdijk ● Solvay Olst ●Stork Heijmans ● Quercus Zoetermeer ● UMC Utrecht ● Imtech ● NRE Eindhoven ● Van Alfen Almere ● Prominent ●Airport Schiphol ● Frico Cheese Bedum ● AMC Health Care ● SuikerUnie ● Deltion College Zwolle ● BAM Techniek ●Tuinderij vd Berg ● Vandenberg Roses ● Stolze/Arthura ● Marjoland ● Westland ● Coca Cola Dongen ● Eneco ●Westmere ● Kester Invest ● NUON Amsterdam RAI ● Van Gelder Airbase Leeuwarden ● Rendo Denmark Kommunekemi Fyn Industri ● BOE Jutland ● Nyborg ● GEAS A/S Grindsted ● Energy Fyn Odense ● Saeby KommunaleElforsyning Germany Eimers GmbH ● Streif Baulogistik ● Emscher Lippe Energie ● Vattenfall HEW United KingdomNCE Radcliffe Hospital ● Rolls Royce Derby ● Royal Hospital London Ireland E&I Engineering Prisons ● TEC Dublin ●Belfast City Hospital Sweden Fortum Service ● Tranäs Energi ● Graniger Kalmar Energi ● Nätstations Alliansen ● MidrocElektro ● Eldistributions-service i Väst ● Vattenvall Service ● Nacka energi ● Holtab AB ● Bjäre Kraft AB ● SkaraborgsElektriska ● Karlstadt Elnät AB ● Skövde Elnat ● Elektroproduktion AB IKEA ● Linjemontage Grästorp ● Elajo RefteleRullpack ● Selga AB Norrahammar ● Höganäs Energi AB ● Ratel Entrepenad AB ● Stockholms Läns Elektriska ●Hideskins Energi Australia City Power Melbourne ● Snowy Hydro ● ETSA Adelaide ● Capral Aluminium Japan NKE Wind Power South Korea Samki Kenya Burhani Norway Troms Kraft Tromse ● Repvag Kraftlag Havoysund ● More Trafo AS Sykkylven Finland Vällnönkatu ● Je-Urakointi OY Switserland Huser & Peyer AG Austria Stadtwerke Schwaz ● Salzburg AG ● EVN AG ● OMV Estonia Tehenergo Tallin Poland Zdzislaw Stachowiak Ostrow Czech Republic SG Brno ●Spectrum Vyskov Ikea Brno ● Zapustkova kovarna China Power Supply Board Shanghai ● Power Supply ShenyangColombia Disico Iceand Karahnjuka Tunnel Belgium STIB Brussel Metro India C&S Reliance Mumbai Hungary ELMU ●Uvill Kft ● MaxCity, Budaörs Italy WE Walter srl

Page 27: Ring Main Units Xiria 3.6 - 24 kV - Eaton

27 27

Technical data

Rated voltagePower frequency withstand voltageImpulse withstand voltageRated current busbarsShort-time current * optional 3 s

rated normal current (max.) circuit-breakersload break switches

Degree of protectionClassification according to IEC 62271-200:Loss of service continuityPartition classInternal arc

122875 / 9563020

200/500630IP 31D

245012563016

200/500 630IP 31D

kVkVkVAkA-1s*

AA

LSC 2BPMIAC AFL 20/16kA-1s

Page 28: Ring Main Units Xiria 3.6 - 24 kV - Eaton

28 28

Standards

Xiria is certified in accordance with:IEC 62271-1 Common specificationsIEC 62271-200 Metal-enclosed switchgearIEC 62271-304 Severe climatic conditionsIEC 62271-100 Circuit-breakers (M1/E2)IEC 62271-103 Load break switches (M1/E3)IEC 62271-102 Disconnector/earthing switches (M0)IEC 62271-102 Earthing via vacuum interrupter (E2)IEC 60529 Degree of protection IEC 60044-1 Current transformers EN 50181 Cable cones

Page 29: Ring Main Units Xiria 3.6 - 24 kV - Eaton

29 29

Quality Assurance

Page 30: Ring Main Units Xiria 3.6 - 24 kV - Eaton

30 30

Summary

• Standards and quality according to IEC and ISO• Green design and fully recyclable• Air insulated with vacuum switching technology• Maintenance free compact design• Visible position indication and visible earthing• Internal arc proof design• Optional remote control• 2-, 3-, 4- and 5-panel units

Page 31: Ring Main Units Xiria 3.6 - 24 kV - Eaton

31 31

Eaton IEC MV Systems

A complete range of compact SF6 free solutions

SVS Unitole UPMMSMagnefix Xiria

Safe – Reliable – Sustainable

Page 32: Ring Main Units Xiria 3.6 - 24 kV - Eaton

32 32