111
www.daikinafrica.com Heating and Air Conditioning Systems RESIDENTIAL & COMMERCIAL CATALOGUE 2008

Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Naamloze Venootschap

Zandvoordestraat 300

B-8400 Oostende, Belgium

www.daikin.eu

BTW BE 0412 120 336

RPR Oostende

w w w . d a i k i n a f r i c a . c o m

H e a t i n g a n d A i r C o n d i t i o n i n g S y s t e m s

R E S I D E N T I A L & C O M M E R C I A L C ATA L O G U E 2 0 0 8

ÉEPCEN08-020&ËÍ

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.

ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.

Daikin units comply with the European regulations that guarantee the safety of the product.

Daikin Europe N.V. participates in the Eurovent Certifi cation Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certifi ed data of certifi ed models are listed in the Eurovent Directory. Multi units are Eurovent certifi ed for combinations up to 2 indoor units. Rooftops are not within the scope of the Eurovent Certifi cation Programme.

The present catalogue is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this catalogue to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fi tness for particular purpose of its content and the products and services presented therein. Specifi cations are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this catalogue. All content is copyrighted by Daikin Europe N.V..

Daikin products are distributed by:

EPCE

N08

-020

• 0

4/20

08 •

Cop

yrig

ht ©

Dai

kin

The

pres

ent

publ

icat

ion

supe

rsed

es E

PCEN

07-0

20Pr

inte

d in

Bel

gium

by

Lann

oo (w

ww

.lann

oopr

int.

be),

a co

mpa

ny w

hose

con

cern

fo

r th

e en

viro

nmen

t is

set

in t

he E

MA

S an

d IS

O 1

4001

sys

tem

s.Re

spon

sibl

e ed

itor:

Dai

kin

Euro

pe N

.V.,

Zand

voor

dest

raat

300

, B-8

400

Oos

tend

e

Resid

ential &

Co

mm

ercial CA

TA

LO

GU

E 2

00

8

W W W. D A I K I N A F R I C A . C O M

Page 2: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Daikin Airconditioning Poland Sp.z o.o.

Daikin Airconditioning Germany Gmbh.Daikin Airconditioning Central EuropeHandelsgmbH.

Daikin Central Europe Czech Republic Spol.s.ro

Daikin Airconditioning Italy SpA

Daikin Europe Middle East Office

Daikin Magyarország Klimatechnikai Kft.

Daikin Airconditioning Greece S.A.

Daikin AirconditioningCentral Europe Romania S.R.L.

Daikin Europe Brussels Office

Daikin Airconditioning Spain

Daikin Airconditioning Portugal

Daikin Europe N.V.Daikin Europe Coordination Center N.V.

Daikin Airconditioning Belgium N.V.Daikin Airconditioning France S.A.S.

Daikin Airconditioning Netherlands B.V.

Daikin Airconditioning UK Ltd.

Daikin Sweden A.B.

Daikin Klima Pazarlama Ltd. Sirketi

Daikin Industries Czech Republic s.ro.

Daikin Europe Moscow Office

Daikin Airconditioning South Africa (PTY) Ltd.

Daikin Europe Dublin Office

The Daikin Europe N.V. groupis a part of Daikin Industries Ltd

Umeda Center Bldg. 4-12, 2-chromeNakazaki-NishiKita-ku, Osaka 530-8323, Japan

Daikin Central Europe Slovakia Spol.s.ro

Daikin Airconditioning Central Europe Slovakia Spol.s.roDaikin Airconditioning Central Europe Predstavnistvo u Republici Hrvatskoj

Page 3: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

1

F o r e w o r d

THE LEADER IN MANUFACTURING QUALITY AND CUSTOMER SERVICESince our establishment in Ostend (Belgium) in 1972, we have updated and expanded our manufacturing facilities, including those opened more recently in Plzen and Brno (Czech Republic) and Cecchina (Italy) – through the acquisition of McQuay - to a point where they are now acknowledged as the most advanced in their fi eld in Europe. Furthermore, all our plants benefi t from our Japanese parent’s policy of zero defect production, super effi cient supply chain management and unrivalled research and development support.

These substantial production facilities are under pinned by a network of wholly owned affi liate companies in the UK, France, Germany, Italy, Spain, Portugal, Poland, Greece, Belgium, Holland and Central Europe, as well as numerous independent distributors throughout Europe, Africa and the Middle East supported by several head offi ces in Ireland, Russia, Turkey, South Africa and the Middle East. Experienced and professional support of this order enables us to maintain an enviably close relationship with international markets, tailor our product programme to suit precise regional requirements and respond quickly and effi ciently to any area of potential market expansion.

THE LEADER IN PRODUCT QUALITYDaikin produces a highly energy effi cient and comprehensive range of quality indoor climate control products and systems for commercial, residential and industrial applications. Our product portfolio is based on four distinct core ‘pillars’:- state of the art direct expansion air conditioning - heat pump residential and light commercial heating, domestic hot water and cooling - applied central cooling and heating - medium to low temperature refrigeration Each pillar harnesses advanced technologies to deliver maximum energy effi ciency and minimum fuel consumption and running costs throughout the equipment life cycle. The width of our product range is also extensive and embracing in its coverage of these key indoor climate control disciplines to a point where we are confi dent of its ability to meet the requirements of our end user, specifi er, contractor and installer customer base at all times.

RESPECT FOR THE ENVIRONMENTDaikin has an enviable record in concern for environmental issues and applies it to all areas of the business, implementing and in many cases pre-empting, international and local environmental protective legislation. We seek to operate a zero waste and zero emissions policy in our manufacturing plants. Our products refl ect the concept of combining maximising energy effi ciency with maximum respect for the environment. Their utilisation of heat pump technology for example, results in far lower energy consumption and in the case of heating, drastically less CO2 emissions than are achievable with fossil fuel burning systems. Also their incorporation of numerous detailed features such as inverter control, heat recovery, economy and quiet operating modes, movement sensors among others, enhance user comfort without compromise to either effi ciency or the environment. Thus, the products contained in this catalogue are designed to represent the best possible answer to your air conditioning needs. Feel free to contact your local Daikin representative for further information and assistance. We are here to serve you!

THE FUTURE LEADERDaikin’s position at the forefront of air conditioning manufacturing and marketing is well established and widely acknowledged. Nevertheless, over the last few years we widened our product portfolio in order to offer customers a more comprehensive choice of indoor climate control solutions for the home, in business and at play. The successful moves into heat pump heating for residential and commercial applications and medium to low temperature refrigeration for retail and wholesale food outlets are testament to this policy. But our search for innovative solutions is ongoing and there will certainly be many more successes to come. The common denominators however, will remain, as they are today, the provision of individual comfort allied to innovation, quality, energy effi ciency and environmental acceptability.

Page 4: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

2

Page 5: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

3

H e a t i n g

Altherma 10

A i r C o n d i t i o n i n g

Residential & Commercial 14Wall mounted units 17Flexi type units 31Floor standing units 32Concealed ceiling units 34Cassette units 504-Way blow ceiling suspended cassette 62Ceiling suspended units 65

Rooftops & Packaged Systems 72Concealed ceiling units 74Rooftops 80

Twin, Triple, Double Twin & Multi Application 82Twin, Triple, Double twin applications 84Multi model applications 98

T a b l e o f C o n t e n t s

Foreword 1Table of contents 3Environmental awareness 4Energy labeling 6Photocatalytic air purifier 8

To consult the explanation of the pictogrammes,please refer to page 107 of this catalogue.

Page 6: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

4

Environmental Awareness

AIR CONDITIONING AND THE ENVIRONMENTAir conditioning systems provide a signifi cant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested enormous efforts in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a signifi cant contribution to limiting the impact on the environment.A number of ‘We Care’ icons are highlighted in green throughout the catalogue to indicate product features that have an impact on reducing energy consumption: Fan only, Night set mode, Econo mode, Energy effi ciency, Movement sensor and Home leave operation

Page 7: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

5

DAIKIN’S COMMITMENT TO THE ENVIRONMENTThe pioneering concern for the environment and natural resources is a part of the entire global Daikin operation at all levels: from product design, manufacturing processes, down to the responsibility each individual Daikin employee takes for the environment.

This commitment is refl ected in three areas: reducing waste in manufacturing and operations, recycling materials, and designing and producing energy-effi cient climate control equipment.

REDUCING WASTE IN MANUFACTURING AND BUSINESS OPERATIONSIn 1998, Daikin Europe N.V. became the fi rst air conditioning manufacturer in Europe to obtain ISO 14001 environmental certifi cation. In addition, since 2004, not only the manufacturing plants but Daikin sales companies as well have obtained ISO 14001 certifi cation, underlining Daikin’s commitment to the environment at all levels of our organisation.

These certifi ed environmental plans include the reduction of waste at all levels. Our environmental targets are high: Daikin Europe N.V. is committed to a zero waste policy whereby as much as possible of its by products can be reused, recycled or recovered as useful resources.

RECYCLING MATERIALSDaikin Europe N.V. is fi rmly committed to recycling materials in all areas of its operations. Wastewater is treated before being discharged into the city drainage system, with the recovered sludge being a useful ingredient in cement manufacturing. Other waste is also carefully sorted and recycled, supported by a continually evolving factory layout that encourages the optimum use of resources. In addition to recycling, we invest signifi cantly in returnable packaging. The same high demands are also imposed on our suppliers.

Eliminating waste and optimum recycling reduce raw material consumption and contribute to effi cient manufacturing and operating processes, meaning fewer burdens on the environment.

ENERGY EFFICIENT CLIMATE CONTROL EQUIPMENTDaikin’s commitment to being a leader in environmental developments has led to a string of innovations in climate control equipment:• Daikin’s use of inverter technology for example reduces start-up time by 33% and allows the compressor to consume

only the power it actually needs to meet the cooling/heating needs of the moment. • Linking the use of inverter technology to reluctance DC compressor motors has further improves effi ciency, allowing

Daikin units to obtain the highest effi ciency ratings in the market. • Daikin also produces computerised air conditioning monitoring and control systems designed to ensure maximum

energy effi ciency at all times, such as Daikin’s latest I-controller technology which offers customers refi ned and energy effi cient control of Daikin heat recovery air conditioning installations, including remote monitoring via the Internet.

This list of innovations could be expanded endlessly. More importantly, it clearly demonstrates that technological innovation and concern for the environment can go hand in hand. At Daikin, these environmental priorities form an integral part of our corporate culture and are refl ected in all of our products.

Choosing Daikin means you can be sure that the cooling systems you use are the safest possible for the environment.

Page 8: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

6

AABB

CCDD

EEFF

GG

Energy Labeling

Energy labeling is part of a wider European Climate Change program that targets energy effi ciency as one method of reducing CO2 emissions in order to meet the targets of the Kyoto protocol. By this means the European Commission hopes that improved awareness will result in customers purchasing the most economical (ecological) answer to their needs.

WHAT?The energy label provides information on the energy consumption of the unit. Air conditioning units (with cooling capacity 12kW) are classifi ed in seven different categories (A to G), according to their energy consumption and color coded according to the category to which they belong. The most energy effi cient units will be included in the A category, indicated by a green arrow on the label – less effi cient units will belong in G class, indicated by a red arrow on the label. The end user can easily compare the effi ciency of equal types of units from different brands.

THE LABEL?WHAT IS MENTIONED ON THE LABEL?Logo and name of manufacturer; name of indoor and outdoor unit (*)

Energy effi ciency class of the unit in cooling mode:

A EER � 3.20

B 3.20 � EER � 3.00

C 3.00 � EER � 2.80

D 2.80 � EER � 2.60

E 2.60 � EER � 2.40

F 2.40 � EER � 2.20

G 2.20 � EER

EnergyManufacturerOutside unitInside unitMore efÞ cient

Less efÞ cientAnnual energy consumption,kWh in cooling mode(Actual consumption will depend on how the apliance is usedand climate)

Cooling output kWEnergy efÞ ciency ratioFull load (the higher the better)

Type Cooling only

Cooling + Heating Air cooled

Water cooledHeat output kW

Heating performanceA: higher G: lower

Noise(dB(A) re 1 pW)

Further information is containedin product brochures

Air-conditionerEnergy Label Directive 2002/31/EC

Page 9: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

7

INDICATED ANNUAL ENERGY CONSUMPTIONThis fi gure indicates the approximate amount of energy consumed per year by the unit, based on a standard household model. The annual consumption is calculated by multiplying the total power input by an average of 500 hr per year IN COOLING MODE AT FULL LOAD. In order to calculate the cost of annual energy consumption, you merely multiply this fi gure by your electricity tariff.

COOLING OUTPUTCooling output is defi ned as the cooling capacity in kW of the appliance, operating in cooling mode at full load. It is important to choose an air conditioning unit with a rated output suffi cient for your cooling/heating requirements. An oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide adequate cooling/heating. To determine the appropriate output, contact the manufacturer or your local dealer/installer.

ENERGY EFFICIENCY RATIO (EER)This is the cooling output of the unit divided by the amount of electricity the unit requires to deliver it (total power input). In other words, the higher the EER, the greater the energy effi ciency.

TYPETYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating systemCOOLING MODE: it indicates if the unit is air cooled or water cooled

HEATING OUTPUTHeating output is defi ned as the heating capacity in kW of the appliance, operating in heating mode at full load.

ENERGY EFFICIENCY CLASS OF THE UNIT IN HEATING MODE:

A EER � 3.60

B 3.60 � EER � 3.40

C 3.40 � EER � 3.20

D 3.20 � EER � 2.80

E 2.80 � EER � 2.60

F 2.60 � EER � 2.40

G 2.40 � EER

Noise level: only for portable units.

(*): For multi-models Daikin chooses only to mention 1 outdoor unit with a maximum of 2 indoor units (wall mounted type) - for other units we refer to the multi brochure.

Page 10: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

8

MC707VM-WMC707VM-S

Photocatalytic Air Purifier

PURE AIR FOR FREE AND HEALTHY BREATHING

• stylish design• improved performance• unprecedented comfort• super quiet operation• easy to maintain• portable• no installation

THREE TIMES PURIFICATION, A GOOD DEED FOR YOUR HEALTH

Pollen, dust and pet hair are just some of the potential causes of allergies, asthma and respiratory problems. A Daikin air purifi er cleans the air and relieves you of these troubles thanks to a three-part operation:

• allergen removal • virus and bacteria removal • odour removal

Pre-filter (with catechin) Removes large dust

particles and pet hairs.

Bio-antibody filterAirborne viruses are

captured and removed.

Plasma ionizerDust and pollen are

positively charged and sent to the electrostatic filter.

Dirty air

Daikin has already received great praise for its air purifi ers: a UK allergy certifi cate and the daikin TüV award confi rm the effi ciency of our units.

Page 11: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

9

MC707VM-SMC707VM-W

Purified air

Flash Streamer High-speed electrons are generated by the Flash

Streamer. These electrons powerfully break down

odours and formaldehyde.

Electrostatic dust collection filter

Positively charged dust and pollen are adsorbed by the negatively charged filter.

Deodorising catalystOdours are adsorbed

and broken down before the air is

returned into the room.

Titanium Apatite Photocatalytic Filter

Odour, bacteria and viruses are adsorbed and decomposed.

Flash Streamer unit

Front

Back

MC707VM-W/S

Model MC707VM-W/SPower supply 1~, 220-240/220-230V, 50/60HzDimensions HxWxD mm 533x425x213Colour (W) = White + sparkling silver or (S) = Sparkling silver + metallic ocean blueWeight Kg 8.7

Mode (50Hz) Turbo H M L SilentPower input kW 0.055 0.023 0.014 0.010 0.008Sound pressure level dB(A) 47 38 31 24 16Sound power level dB(A) 62 52 40 39 31Air fl ow rate m3/h 420 285 180 120 60Dust collecting method Plasma ionizer (electrostatic dust collection) + Electrostatic dust collection fi lterDeodorising Method Flash Streamer + Titanium apatite photocatalytic fi lter + Deodorising catalyst

Deodorising performance (%) 95Regenerate method The Flash Streamer activates the photocatalytic reaction

Bacteria fi ltering method Bio-Antibody fi lter + Flash Streamer + Titanium apatite photocatalytic fi lterFilter Dust

collection and deodorisation

Form Pleated fi lterFunction Deodorisation + disinfection + dust collection + adjuvant removalLifetime 1 fi lter/1 year

Bio-Antibody fi lter NewPre-fi lter Catechin pre-fi lter

Page 12: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

10

CHOOSING ALTHERMA ... NOTHING BUT BENEFITS!

LESS ENERGY, PLEASANT WARMTH IN THE HOME

Altherma heats up to 3 times more effi ciently than a traditional heating system based on fossil fuels or electricity. By making use of the heat in the outside air, you use much less energy, while still enjoying a stable, pleasant heat in your surroundings.On top, maintenance requirements are minimal, making your running cost low. Thanks to the inverter technology, your energy savings are even greater.

MINIMAL INSTALLATION COST

Altherma takes heat from the air. No digging or excavation works are required. Both the outdoor and indoor units are compact. The external unit can be located easily outside any building, including apartments. Without fl ames or fumes, there is no need for a chimney or constant ventilation in the room, where Altherma’s indoor unit is installed.

FLEXIBLE CONFIGURATIONS

Altherma can be confi gured for use in both new and refurbishment applications and connects to standard low temperature radiators, under fl oor heating or fan coil units. If you already have a heating system, you don’t need to change everything.

COMPLETE COMFORT FOR YOUR FAMILY

Altherma satisfi es your heating requirements but it can also supply your sanitary hot water and it comes with a cooling option for hot summer days.

ABSOLUTELY SAFE

Altherma doesn’t need oil, gas or other hazardous substances – naturally reducing a potential risk that goes together. Moreover, you don’t need a gas connection or a fuel tank. No risk of intoxication, smell or pollution from leaking tanks.

The intelligent way to comfort

Page 13: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

11

INDOOR UNIT

EKHBH008AA*** EKHBX008AA*** EKHBH016AB*** EKHBX016AB***Function Heating only Reversible Heating only ReversibleDimensions HxWxD mm 922x502x361 922x502x361 922x502x361 922x502x361Leaving water temperature range

heating °C 15~50 15~55cooling °C - 5~22 - 5 - 22

Drain valve YesMaterial Epoxy polyester painted galvanized steelColour RAL 9010 (neutral white)

FACTORY MOUNTED HEATERPower supply Capacity steps

EKHBH(X)008AA3V3 / EKHBH(X)016AB3V3 1 ~/230V 1EKHBH(X)008AA6V3 / EKHBH(X)016AB6V3 1 ~/230V 2EKHBH(X)008AA6WN / EKHBH(X)016AB6WN 3 ~/400V 2EKHBH(X)008AA6T1 / EKHBH(X)016AB6T1 3 ~/230V 2EKHBH(X)008AA9WN / EKHBH(X)016AB9WN 3 ~/400V 2EKHBH(X)008AA9T1 / EKHBH(X)016AB9T1 3 ~/230V 2

OUTDOOR UNIT

ERHQ006AD ERHQ007AD ERHQ008AD ERHQ011AA ERHQ014AA ERHQ016AADimensions HxWxD mm 735x825x300 1,349x980x420Nominal capacity* heating kW 5.75 6.64 8.43 11.2 14.0 16.0

cooling kW 7.20 8.16 8.37 13.9 17.3 17.8Nominal input heating kW 1.26 1.58 2.08 2.46 3.17 3.83

cooling kW 2.27 2.78 2.97 3.79 5.78 6.77COP 3.18 3.13 3.00 4.55 4.42 4.18EER 2.37 2.26 2.21 3.67 2.99 2.63Operation range heating °C -20 ~ 25 -20 ~ 35

cooling °C 10 ~43 10 ~43domestic mode °C -20 ~ 43 -20 ~ 43

Sound pressure level

heating dBA 61 61 62 64 64 66cooling dBA 63 63 63 64 66 69

Weight kg 56 103Refrigerant charge R-410A kg 1.7 3.7Power supply 1 ~ /230V/50Hz 1 ~ /230V/50HzRecommended fuses A 20 32

* Measuring conditions EKHBH(X)008AA: Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT=5°C) - Cooling Ta 35°C - LWE18°C (DT=5°C)Measuring conditions EKHBH(X)016AB: Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT=5°C) - Cooling Ta 35°C - LWE18°C (DT=5°C)

DOMESTIC HOT WATER TANK

EKHWS150A3V3 EKHWS200A3V3 EKHWS300A3V3 EKHWS2003Z2 EKHWS200A3Z2Water volume l 150 200 300 200 300Max. water temperature °C 85Height mm 900 1,150 1,600 1,150 1,600Diameter mm 580Booster heater kW 3Power supply 1 ~ /230V/50Hz 2 ~ /400V/50HzMaterial inside tank Stainless steel (DIN 1.4521)Material outside casing Epoxy-coated mild steelColour Neutral whiteEmpty weight kg 37 45 59 45 59

SOLAR KIT

EKSOLHWAV1Dimensions HxWxD mm 770x305x207Heat exchanger pressure drop kPA 21.5

Max. inlet temp °C 110heat ex. capacity W/K 1,400

Ambient temperature

max. °C 35min. °C 1

Power supply 1~/220-240V/50HzPower supply intake indoor unit

Page 14: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

12

The solution for your total comfort

Altherma is a split system consisting of an outdoor unit and an indoor hydro-box that can be connected to all standard low temperature radiators and underfl oor heating systems.

OUTDOOR UNIT

An effi cient use of energy from the airAltherma uses a natural, renewable source of energy.The outdoor unit derives heat from the surrounding air and raises its temperature until it is high enough to heat a home. This heat is then transmitted to the indoor unit through refrigerant pipes. An advantage of this is that the pipes can never freeze. The compact outdoor unit is easily installed and can also be used in residences without a garden.

INDOOR UNIT

The heart of the altherma systemThe indoor unit heats the water that circulates through your low temperature radiators, fl oor heating systems or fan coil units and provides you with domestic hot water. If you opt for the combination of heating and cooling, then the indoor unit can also decrease the water temperature to distribute a refreshing coolness.

Did you know that...

The altherma system can be perfectly combined with solar collectors to produce hot water. The sun provides 30 to 70% of the energy required for our hot water needs. Altherma, your total solution, thinks of the future.

?

Outdoor unit

Indoor unit

Domestic hot water tank

Page 15: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

13

DOMESTIC HOT WATER TANK

For low energy cosumptionAs for your domestic hot water, Altherma is just as clever. The unique lay-out and special placement of different elements maximise energy effi ciency. The water inside the storage tank is primarily warmed up by thermal energy from the outside air, thanks to a heat exchanger connected to the heat pump. However, an additional electrical heating element in the domestic water tank can take care of extra heat you need in your shower, bath or sink. At necessary intervals the water is automatically heated to 70°C in order to stay clear of bacteria. With Altherma you can enjoy delightfully warm and perfectly safe water at all times. Depending on the daily consumption of hot water, Altherma domestic hot water tanks come

in three different sizes, with the largest one being the most effi cient.

INTELLIGENT TEMPERATURE REGULATOR

The operation of the system is integrated in the indoor unit. With Altherma, it is possible to regulate your heating and (optional) cooling system according to your needs. Your installer can set up a full weekly programme for you, per hour or per day. In this way, the temperature is reduced automatically at night or during your holiday, and it is once again pleasantly warm when you get up or return home. The fl oating setpoint, is a built-in variable thermostat that adjusts the water temperature to the outdoor temperature.By keeping the water temperature at the lowest possible level, maximum effi ciency of the system is achieved. The system can be combined with additional temperature regulating systems with separate thermostats for living rooms, bedrooms, and so forth.

Fan coil unit

Low temperature radiator

Domestic hot water

Under fl oor heating

Page 16: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

14

Page 17: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

15

FTXR-E / RXR-E 17FTXG-E / RXG-E 19FTXS-G / RXS-G 21FTX-GV / RX-GV 22FTXS-F / RXS-F 23FTYN-GX / RYN-GX 24FTYN-F / RYN-E 25FAQ-B / RQ-B 26FAQ-B / RZQS-C 27FAQ-B / RZQ-C 28FAQ-B / RZQ-B 29

FLXS-B / RXS-G 31

FVXS-F / RXS-G 32FVQ-B / RZQS-C 33

FDXS-E / RXS-G 34FDXS-C / RXS-G 35FDXS-C / RXS-F 36FBQ-B / RXS-G 38FBQ-B / RXS-F 39FBQ-B / RQ-B 40FBQ-B / REQ-B 41FBQ-B / RZQS-C 42FBQ-B / RZQ-B 43FDQ-B / RQ-B 44FDQ-B / RZQS-C 45FDQ-B / RZQ-C 46FDQ-B / RZQ-B 47FDEQ-B / REQ-B 49

FCQ-C / RXS-G 50FCQ-C / RXS-F 51FCQ-C / RQ-B 52FCQ-C / REQ-B 53FCQ-C / RZQS-C 54FCQ-C / RZQ-C 55FCQ-C / RZQ-B 56FCQH-C / RZQS-C 57FCQH-C / RZQ-C 58FCQH-C / RZQ-B 59FFQ-B / RXS-G 60FFQ-B / RXS-F 61

FUQ-B / RQ-B 62FUQ-B / RZQ-C 63FUQ-B / RZQ-B 64

FHQ-B / RXS-G 65FHQ-B / RXS-F 66FHQ-B / RQ-B 67FHQ-B / REQ-B 68FHQ-B / RZQS-C 69FHQ-B / RZQ-C 70FHQ-B / RZQ-B 71

1. Wall mounted unit

2. Flexi type units

3. Floor standing units

4. Concealed ceiling units

5. Cassette units

6. 4-Way blow ceiling suspended cassettes

7. Ceiling suspended units

Daikin residential air conditioning is the modern, economic and effi cient way to switch on to springtime - in the living room, dining room, kitchen or bedroom, night and day, throughout the year.Daikin air conditioning units are easy to install, easy to use, ultra reliable, quiet running and come in an elegant and up to date range of wall, fl oor and ceiling mounted indoor models. Also, the incorporation of inverter control enables Daikin to bring air conditioning technology of the future to the residential market today. Inverter control cuts start up time and energy consumption by almost a third, alters unit output to suit outdoor conditions, improves performance relative to power input, ensures a more even room temperature and eliminates power surges and stop/start cycles.

Residential & Commercial

newnew

new

new

Page 18: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Good Design Award

16

URURU SARARAA unique combination of humidifi cation, dehumidifi cation, ventilation and air purifi cation

Good temperature control is not all that is needed for a comfortable indoor climate. Precision control of humidity and ventilation of the room is essential. Thanks to the URURU SARARA, you can humidify, dehumidify, ventilate and purify. The unit is fi tted with fi lters that also fi lter dust, pollen and smoke. You can also adjust the air purifi cation to meet your specifi c needs. Thanks to the ventilation system, contaminated indoor air in a space is replaced with fresh outdoor air.

URURU humidifi cation: Pleasant, even during heating

The URURU humidifi cation system absorbs moisture from the outdoor air and transports it to the indoor unit, quickly and effi ciently humidifying the room. Thanks to the perfect combination of humidifi cation and air conditioning, your room heats evenly.

SARARA dehumidifi cation: Feel the difference!

When humidity is too high, the SARARA dehumidication system ensures that it is lowered without changing the room temperature. That is ideal for you, because lower humidity means you feel more comfortable.

• The ideal humidity• Comfortable air fl ow• Powerful air purifi cation• Stylish design (good design award)• Energy saving and high effi ciency: one unit of energy is

converted into more than fi ve units of energy for cooling or heating

Page 19: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! URURU humidifi cation: maintains a comfortable humidity level without any separate water supply

! SARARA dehumidifi cation: maintains a comfortable and fresh indoor environment by removing moisture from the air without lowering the temperature

! Energy effi cient: full range A class labels (EER = 5.00/COP = 5.14)

! Powerful ventilation: refreshes the room within 2 hours

! Powerful air purifi cation: increases indoor air quality with Daikin Flash Streamer technology

! Comfortable air fl ow! Stylish design! Other features: moisturizing operation mode,

breeze cooling air fl ow, comfort sleep operation, mould shock operation

HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXR28EV1B9 FTXR42EV1B9 FTXR50EV1B9Capacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kW

Standard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling Medium dBA

Heating Medium dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXR28EV1B9 RXR42EV1B9 RXR50EV1B9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

5 steps

Titanium apatite photocatalytic air purifi cation fi lter

optional

1.55

2.8 4.2 5.0

3.6 4.60 5.50

1.30

3.6 5.1 6.0

5.00 5.6 6.20

5.00 / 5.14 4.00 / 4.32 3.42 / 3.97

280 525 730

A / A

209x890x30514

11.1 / 8.8 / 6.5 / 5.7 12.4 / 9.6 / 6.8 / 6.0 13.3 / 10.3 / 7.3 / 6.512.4 / 9.8 / 7.3 / 6.5 12.9 / 10.2 / 7.7 / 6.8 14.0 / 11.1 / 8.3 / 7.3

55 58 6057 58 60

39 / 33 / 26 / 23 42 / 35 / 27 / 24 44 / 37 / 29 / 2641 / 35 / 28 / 25 42 / 36 / 29 / 26 44 / 38 / 31 / 28

R-410A1~/220-240V/50Hz

693x795x28548

-10~43-20~18

60 6246 4846 48 50

R-410A1~/220-240V/50Hz

6.35 / 9.52 / 1810

FTXR-E / RXR-E

17

RXR28,42,50EFTXR28,42,50EARC447A

Page 20: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Good Design Award

FTK(X)S FTXG

18

STYLISH AND COMPACT DESIGN

Daikin succeeded in creating an indoor unit with such a sleek profi le, that you won’t believe it is an air conditioning unit.In standby mode, the discharge opening is closed, resulting in a compact depth of only 15cm.When starting the unit up, the entire front panel slides smoothly open.

For this model, Daikin even received the “Good Design Award” in Japan.

SENSATIONAL THINNING TECHNOLOGY

• High effi ciency slit fi n heat exchanger

• Miniature cross fl ow fan

The blade confi guration has been optimized to achieve quiet operation and powerful air fl ow, while reducing the fan’s diameter by 20% compared to conventional models.

SUPERB ENERGY EFFICIENCY

Daikin has further improved the energy effi ciency. At the same time it realized substantial energy savings compared to conventional models by achieving an industrial top class EER of 4.03 and COP of 4.15.These top of the class values are achieved by the following 3 technologies:

• PAM Inverter control• Reluctance DC motor + DC Fan motor• Swing compressor

CLEAN AND COMFORTABLE AIR FLOW

For the fi st time in history, a titanium apatite photocatalytic air purifi cation fi lter is integrated in an air conitioning unit. This to increase the active surface area for effective purifi cation and deodorisation, even when a high volume of air is required.

Super quiet:The indoor/outdoor unit silent operation function brings us comfort by offering an industry top-level quiet operation of 22dB(A) for the indoor unit and 43dB(A) for the outdoor unit.

COMFORT MODE

The new wide-angle distribution fl ap reassures draught free operation. During cooling operation the fl ap angle turns horizontally to prevent cold air blowing directly on the body, while during heating operation it turns downward vertically to send the warm air directly to the feet.

3-D AIR FLOW

This function combines Vertical and Horizontal auto-swing to circulate a stream of cool/warm air right to the corners of even large spaces.

25% size reduction Cooling mode Heating mode

Designed for people who do not only care for quality but also

care for stylish design

Page 21: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! State of the art design: sleek, compact and stylish outlook

! Available in 2 colour variations: mat crystal white and mat crystal silver

! Lightweight and compact! Easy to clean fl at suction grille! Superb energy effi ciency! Movement sensor saves power consumption in

unoccupied rooms! Comfort mode reassures draught free operation

thanks to the new wide angle distribution fl ap! The new titanium apatite photocatalytic air

purifi cation fi lter increases the active surface area for effective purifi cation and deodorisation

! Horizontal and vertical auto-swing 3D-air fl ow ensure effi cient air and temperature distribution.

! Powerful mode can be selected for rapid cooling or heating

! Indoor / outdoor unit silent operation

HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXG25EV1BW FTXG25EV1BS FTXG35EV1BW FTXG35EV1BSCapacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kW

Standard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXG25E2V1B RXG35E2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

(5 steps) (standard)

(integrated titanium apatite)

(optional)

1.3 1.4

2.5 3.5

3.0 3.8

1.3 1.4

3.4 4.2

4.5 5.0

4.03 / 4.15 3.30 / 3.72

310 530

A / A

275x840x1509.0

7.7 / 6.1 / 4.7 / 3.8 8.1 / 6.5 / 4.9 / 4.19.0 / 7.9 / 6.7 / 5.4 9.6 / 8.2 / 6.7 / 5.9

56.0 57.056.0 57.0

38.0 / 32.0 / 25.0 / 22.0 39.0 / 33.0 / 26.0 / 23.038.0 / 33.0 / 28.0 / 25.0 39.0 / 34.0 / 29.0 / 29.0

R-410A1~/220-240V/50Hz

550x765x28532

10.0~46.0-15.0~20.0 -15~20

61.0 62.046.0 47.047.0 48.0

R-410A1~/230V/50Hz6.35 / 9.52 / 18

2015.0

FTXG-E / RXG-E

19

RXG25,35E FTXG25,35E_S FTXG25,35E_WARC433A41

MXS

Page 22: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

20

ARC452A3

SPECIAL FEATURES

2 area intelligent eye

With this function, the air fl ow is sent to a zone other than where the person is located at that moment.If two people are detected in the room, the movement sensor, together with the comfort mode (cooling directed at the ceiling, heating directed at the fl oor), will see to it that the air fl ow is projected away from the occupants. If no people are detected, the unit will automatically switch over to the energy-effi cient setting.

Remote control

The new infrared remote control has a very stylish design, is user-friendly and equipped with a weekly timer. With this timer, you can programme a 7-day schedule with 4 different actions per day.Furthermore, the convenient copy function allows you to very quickly copy any day’s programme to one or more other days. Should there be a malfunction in the air conditioner, you can read the code on the LCD screen of the remote control and easily fi nd the appropriate solution.

Energy saving during operation standby

Once the standby current-saving function has been activated, the current consumption when operating on standby will be reduced by about 80%. If no people are detected for an extended period of time, i.e. more than 20 minutes, the system will automatically switch to the current-saving mode.

High tech on the inside,Att ractive design on the outside

Page 23: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! 2 area intelligent eye: air fl ow is sent to the area in a room where no person is detected

! Energy saving during stand by mode: reduction of energy from 10W to 2W

! Weekly timer: allows to program the unit on a weekly basis

! Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.

! Comfort mode reassures draught free operation! 3D air fl ow! Dual air discharge fl ow for better air distribution! Consumes up to 30% less energy than non-

inverter units! ECONO mode decreases power consumption

so that other appliances that need large power supply can be used

! Indoor / outdoor unit silent operation! Powerful mode can be selected for rapid cooling

or heating! Reaches set temperature more quickly! Titanium apatite photocatalytic air purifi cation fi lter

absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses

HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Capacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kW

Standard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/min

Heating High m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS20G2V1B RXS25G2V1B RXS35G2V1B RXS42G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

5 steps

standard

(integrated titanium apatite)

1.3 1.3 1.4 1.7 1.7

2.0 2.5 3.5 4.2 5.0

2.8 3.2 4.0 5.0 5.3

1.3 1.3 1.4 1.7 1.7

2.7 3.4 4.0 5.4 5.8

4.3 4.7 5.2 6.0 6.5

4.26 / 4.29 4.55 / 4.53 4.02 / 4.17 3.44 / 3.67 3.29 / 3.69

235 275 435 610 760

A / A A / A A / A A / A A / A

295x800x215 295x800x215 295x800x215 295x800x215 295x800x2159 9 10 10 10

9.0 9.0 10.1 9.8 10.29.3 9.6 10.5 10.1 10.954 54 57 58 5954 55 57 58 60

38 / 32 / 25 / 22 38 / 32 / 25 / 22 42 / 34 / 26 / 23 42 / 38 / 33 / 30 43 / 39 / 34 / 3138 / 33 / 28 / 25 39 / 34 / 28 / 25 42 / 36 / 29 / 26 42 / 38 / 33 / 30 44 / 39 / 34 / 31

R-410A R-410A R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz

550x765x285 550x765x285 550x765x285 550x765x285 735x825x30034 34 34 39 48

-10~46 -10~46 -10~46 -10~46 -10~46-15~20 -15~20 -15~20 -15~20 -15~18

61 61 63 63 6243 43 44 44 4444 44 45 45 4546 46 48 48 4847 47 48 48 48

R-410A R-410A R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 20 20 30

FTXS-G / RXS-G

21

RXS20,25,35,42GFTXS20,25,35,42,50GARC452A3

Page 24: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.

! Lightweight and compact! Consumes up to 30% less energy than non-

inverter units! Dual air discharge fl ow for better air distribution! ECONO mode decreases power consumption

so that other appliances that need large power supply can be used

! Indoor unit On/Off switch! Indoor unit silent operation! Titanium apatite photocatalytic air purifi cation fi lter! Anticorrosion treatment of outdoor heat

exchanger fi n! Powerful mode can be selected for rapid cooling

or heating! Energy saving during stand by mode: reduction of

energy from 10W to 2W

HEAT PUMP INVERTERIndoor UnitsIndoor Units FTX20GV1B FTX25GV1B FTX35GV1BCapacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kW

Standard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RX20GV1B RX25GV1B RX35GV1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

5 steps standard

1.3

2.0 2.5 3.2

2.6 3.0 3.8

1.3

2.5 2.8 3.4

3.5 4.0 4.8

3.62 / 3.90 3.38 / 3.68 3.37 / 3.74

275 370 470

A / A

283x770x1987

9.1 / 7.4 / 5.9 / 4.7 9.2 / 7.6 / 6.0 / 4.8 9.3 / 7.7 / 6.1 / 4.99.4 / 7.8 / 6.3 / 5.5 9.7 / 8.0 / 6.3 / 5.5 10.1 / 8.4 / 6.7 / 5.7

55 56 5755 56 57

39 / 33 / 25 / 22 40 / 33 / 26 / 22 41 / 34 / 27 / 2339 / 34 / 28 / 25 40 / 34 / 28 / 25 41 / 35 / 29 / 26

R-410A1~/220-230-240V/50Hz

550x658x27528 30

10~46-15~20

60 6246 4847 48

R-410A1~/220-230-240V/50Hz

6.35 / 9.52 / 1815

FTX-GV / RX-GV

22

RX20,25,35GVFTX20,25,35GVARC433A87

Page 25: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.

! Lightweight and compact! Home leave operation saves energy during

absence! Movement sensor saves power consumption in

unoccupied rooms! Dual air discharge fl ow for better air distribution! Titanium apatite photocatalytic air purifi cation fi lter! Indoor / outdoor unit silent operation

HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXS60FV1B FTXS71FV1BCapacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kW

Standard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling Medium dBA

Heating Medium dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS60F2V1B RXS71FV1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

5 steps

standard MXS

1.7 2.3

6.0 7.1

6.7 8.5

1.7 2.3

7.0 8.2

8.0 10.2

3.02 / 3.43 3.02 / 3.22

995 1175

B / B B / C

290x1050x23812

16.2 / 13.6 / 11.4 / 10.2 17.4 / 14.6 / 11.6 / 10.617.4 / 15.1 / 12.7 / 11.4 19.7 / 16.9 / 14.3 / 12.7

61 6260 62

45 / 41 / 36 / 33 46 / 42 / 37 / 3444 / 40 / 35 / 32 46 / 42 / 37 / 34

R-410A1~/220-240V/50Hz

735x825x300 770x900x32048 71

-10~46-15~18

63 6649 5249 5246 49

R-410A1~/220-240/220-230V/50Hz

6.35 / 12.7 / 18 6.35 / 15.9 / 1830

FTXS-F / RXS-F

23

RXS60,71FFTXS60,71FARC433A70

Page 26: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

Fits neatly on a wall Wide angle louvers provide a comfortable air fl ow

throughout the entire room 24-Hour On/Off timer Indoor unit On/Off switch Power-airfl ow fl ap Anti-corrosion treated plate type heat exchangers

HEAT PUMP NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low dBA

Heating High/Medium/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD) /Gas / Drain mmPiping Length (Maximum) m

optional

3 steps standard

FTYN25GXV1B FTYN35GXV1B2.5 3.21

2.85 3.583.25 / 3.65 3.21 / 3.61

385 500

A / A A / A

288 x 800 x 204 288 x 800 x 2049 9

9.5 9.8- -- -

38 / 32 / 27 38 / 24 / 2938 / 33 / 27 40 / 35 / 29

R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz

RYN25GXV1B RYN35GXV1B550 x 765 x 285 550 x 765 x 285

31 34 10~46 10~46-10~24 -10~24

- -48 4949 50

R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52 / 18 6.35 / 12.7 / 1815 15

FTYN-GX / RYN-GX

24

RYN25,35GXARC461A3 FTYN25,35GX

Page 27: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.

! Lightweight and compact! Titanium apatite photocatalytic air purifi cation fi lter! Powerful mode can be selected for rapid cooling

or heating! Auto-swing function ensures effi cient air and

temperature distribution.

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FTYN50FV1B FTYN60FV1BNominal Capacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min

Heating High/Medium/Low m³/minSound Power Cooling Medium dBA

Heating Medium dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RYN50E3V1B RYN60E3V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional 5 steps

standard 50 + 60 class

5.0 6.0

5.8 7.0

3.23 / 3.63 3.02 / 3.43

775 995

A / A B / B

290x1050x23812

14.7 / 12.4 / 10.3 16.2 / 13.6 / 11.416.1 / 13.9 / 11.5 17.4 / 15.1 / 12.7

59 6158 60

43 / 34 45 / 3642 / 33 44 / 35

R-410A1~/220-240V/50Hz

735x825x30048

-10.0~46.0-15~18

61.0 63.047.0 49.048.0 49.0

R-410A1~/220-240V/50Hz

6.35 / 12.7 / 1830

20.0

FTYN-F / RYN-E

25

RYN50,60EFTYN50,60FARC433A72

Page 28: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! Fits neatly on a wall! Ideal for shops, restaurants or offi ces requiring

maximum fl oor space for furniture, decorations and fi ttings

! Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off

! Automatic movable louver can be fi xed at any desired angle

! Both horizontal fl aps and front panel can easily be removed and washed

! All maintenance operations can be carried out from the front of the unit

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional

2 steps

optional optional

heat pump optional

7.1 7.1 10.0 10.0

8.0 8.0 11.2 11.2

2.68 / 3.10 2.81 / 3.21 2.81 / 2.83 2.84 / 2.93

1325 1265 1780 1760

D / D C / C C / D C / D

290x1050x230 360x1570x20013.0 26.0

19.0 / 15.0 23.0 / 19.019.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.043.0 / 37.0 45.0 / 41.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32084 83 103 101

-5.0~46.0-10.0~15.0

63.0 66.050.0 53.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26700.5

FAQ-B / RQ-B

26

RQ100BFAQ71B BRC1D52 BRC7E618/C510

Page 29: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring

maximum fl oor space for furniture, decorations and fi ttings

Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off

Automatic movable louver can be fi xed at any desired angle

Both horizontal fl aps and front panel can easily be removed and washed

All maintenance operations can be carried out from the front of the unit

HEAT PUMP INVERTERIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional

2 steps optional

optional

optionalheat pump

7.1 10.0

8.0 11.2

2.81 / 3.07 2.45 / 3.00

1,265 2,040

C / D E / D

290x1050x230 360x1570x20013.0 26.0

19.0 / 15.0 23.0 / 19.019.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.043.0 / 37.0 45.0 / 41.0

R-410A1~/220-240V/50Hz

770x900x320 700x900x32068

-5~46-15~15.5

65 6749 5151 5547 49

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2630 50

0.5

FAQ-B / RZQS-C

27

RZQS71,100CFAQ71B BRC1D52 BRC7E618/510

Page 30: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! Fits neatly on a wall! Ideal for shops, restaurants or offi ces requiring

maximum fl oor space for furniture, decorations and fi ttings

! Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off

! Automatic movable louver can be fi xed at any desired angle

! Both horizontal fl aps and front panel can easily be removed and washed

! All maintenance operations can be carried out from the front of the unit

HEAT PUMP INVERTERIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump

optional

2 steps optional

optional

optional

7.1 10

8.0 11.2

3.01 / 3.31 2.9 / 3.43

1,180 1725

B / C C / B

290x1050x230 360x1570x20013.0 26.0

19.0 / 15.0 23.0 / 19.019.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.043.0 / 37.0 45.0 / 41.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32067 103

-15.0~50.0-20.0~15.5

63 6547 4949 5143 45

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2650 75

0.5

FAQ-B / RZQ-C

28

FAQ71B BRC1D52 BRC7E618 RZQ71C

Page 31: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Wall Mounted Unit

! Fits neatly on a wall! Ideal for shops, restaurants or offi ces requiring

maximum fl oor space for furniture, decorations and fi ttings

! Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off

! Automatic movable louver can be fi xed at any desired angle

! Both horizontal fl aps and front panel can easily be removed and washed

! All maintenance operations can be carried out from the front of the unit

HEAT PUMP INVERTERIndoor UnitsIndoor Units FAQ100BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ100B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump

optional

2 steps optional

optional

optional

10.00

11.20

3.60 / 3.30

1390

A / C

360x1570x20026.0

23.0 / 19.023.0 / 19.061.0 / 57.061.0 / 57.045.0 / 41.045.0 / 41.0

R-410A1~/220-240V/50Hz

1345x900x320106

-15.0~50.0-20.0~15.5

65.049.051.045.0

R-410A1~/400V/50Hz9.52 / 15.9 / 26

750.5

FAQ-B / RZQ-BW1

29

RZQ100BFAQ71B BRC1D52 BRC7E618/C510

Page 32: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

30

Page 33: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Flexi Type Unit

! Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window

! Consumes up to 30% less energy than non-inverter units

! Washable front panel! Reaches set temperature more quickly! Auto-swing function ensures effi cient air and

temperature distribution.! Home leave operation saves energy during

absence! Air purifi cation fi lter! Powerful mode can be selected for rapid cooling

or heating! Indoor / outdoor unit silent operation

optional 5 steps

standard

MXS

HEAT PUMP INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / HeatingAnnual energy consumption kWhEnergy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

FLXS25BAVMB FLXS35BAVMB FLXS50BAVMB

1.2 1.2 0.92.5 3.5 4.93.0 3.8 5.31.2 1.2 0.93.4 4.0 6.14.5 5.0 7.5

3.85 / 3.47 3.10 / 3.25 2.85 / 3.35

325 565 860A / B B / C C / C

490x1050x200 490x1050x200 490x1050x20016.0 16.0 17.0

7.60 / 6.80 / 6.00 / 5.2 8.60 / 7.60 / 6.60 / 5.6 11.40 / 10.00 / 8.50 / 7.69.20 / 8.30 / 7.40 / 6.6 9.80 / 8.90 / 8.00 / 7.2 12.1 / 9.8 / 7.5 / 6.8

53.0 54.0 63.0- - 62.0

37.0 / 34.0 / 31.0 / 28.0 38.0 / 35.0 / 32.0 / 29.0 47.0 / 43.0 / 39.0 / 36.037.0 / 34.0 / 31.0 / 29.0 39.0 / 36.0 / 33.0 / 30.0 46.0 / 41.0 / 35.0 / 33.0

R-410A R-410A R-410A1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz

RXS25G2V1B RXS35G2V1B RXS50G2V1B550x765x285 550x765x285 735x825x300

34 34 48-10~46 -10~46 -10~46-15~20 -15~20 -15~18

61 63 6243 44 4444 45 4546 48 4847 48 48

R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 30

FLXS-B / RXS-G

31

RXS25,35GFLXS25,35,50BARC433A6

Page 34: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Floor Standing Unit

! Weekly timer: allows to program the unit on a weekly basis

! Stylish design! Flat front panel: its stylish appearance blends easily

within any interior décor and is more easy to clean.! Titanium apatite photocatalytic air purifi cation fi lter! Can be installed against a wall or recessed! Dual air discharge fl ow for better air distribution! ECONO mode decreases power consumption

so that other appliances that need large power supply can be used

! Lightweight but sturdy design

HEAT PUMP INVERTERIndoor UnitsIndoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1B Capacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS25G2V1B RXS35G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

5 steps standard

Titanium apatite photocatalytic air purifi cation fi lter

1.3 1.4 1.42.5 3.5 5.03.0 3.8 5.61.3 1.4 1.43.4 4.5 5.84.5 5.0 8.1

4.39 / 4.30 3.43 / 3.69 3.23 / 3.63

285 510 775

A / A A / A A / A600x700x210 600x700x210 600x700x210

14 14 148.2 / 6.5 / 4.8 / 4.1 8.5 / 6.7 / 4.9 / 4.5 10.7 / 9.2 / 7.8 / 6.68.8 / 6.9 / 5.0 / 4.4 9.4 / 7.3 / 5.2 / 4.7 11.8 / 10.1 / 8.5 / 7.1

54 55 5654 55 57

38 / 32 / 26 / 23 39 / 33 / 27 / 24 44 / 40 / 36 / 3238 / 32 / 26 / 23 39 / 33 / 27 / 24 45 / 40 / 36 / 32

R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz

550x765x285 550x765x285 735x825x30034 34 48

-10~46 -10~46 -10~46-15~20 -15~20 -15~18

61 63 6243 44 4444 45 4546 48 4847 48 48

R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 30

FVXS-F / RXS-G

32

RXS25,35GFVXS25,35,50FV1BARC452A1

Page 35: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Floor Standing Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Very effi cient for use in rooms with high ceilings! Quiet operation: down to 35 dBA sound pressure

level (71 class)! Auto-swing function ensures effi cient air and

temperature distribution.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FVQ71BV1B FVQ100BV1B FVQ125BV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kWEER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

2 steps

optional

7.1 10 12.58 11.2 14

2.81 / 3.21 2.49 / 2.81 2.81 / 3.21

1,265 2,010 2,225C / C E / D C / C

1,850 x 600 x 270 1,850 x 600 x 350 1,850 x 600 x 35039 46 47

54 / 48 60 / 54 62 / 5654 / 48 60 / 54 62 / 5642 / 36 48 / 42 50 / 4442 / 36 48 / 42 50 / 44R-410A R-410A R-410A

1~ / 220-240V / 50Hz 1~ / 220-240V / 50Hz 1~ / 220-240V / 50Hz

770 x 900 x 320 700 x 900 x 320 1,170 x 900 x 32068 103

-5~46-15~15.5

65 6749 5151 55 5347 49

R-410A220-240V/50Hz9.52 / 15.9 / 26

30 500.5

FVQ-B / RZQS-C

33

RZQS125CFVQ-B

Page 36: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Slim Concealed Ceiling Unit

! Slim design for fl exible installation! Compact dimensions, can easily be mounted in a

ceiling void! Blends unobtrusively with any interior décor! Can be installed in both new and existing

buildings.! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Powerful mode can be selected for rapid cooling

or heating

! Home leave operation saves energy during absence

! Standard suction fi lter: removes airborne dust particles to ensure a steady supply of clean air

! Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .

! Medium external static pressure facilitates unit use with fl exible ducts of varying lengths

HEAT PUMP INVERTERIndoor UnitsIndoor Units FDXS25EAVMB FDXS35EAVMB Capacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS25G2V1B RXS35G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

5 steps standard

1.3 1.42.4 3.43.0 3.81.3 1.43.2 4.04.5 5.0

3.48 / 3.52 3.12 / 3.39

345 545

A / B B / C200x700x620 200x700x620

21.0 21.08.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.28.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.2

53.0 53.053.0 53.0

35.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.035.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.0

R-410A R-410A1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz

550x765x285 550x765x28534 34

-10~46 -10~46-15~20 -15~20

61 6343 4444 4546 4847 48

R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52/18 6.35 / 9.52/1820 20

FDXS-E / RXS-G

34

RXS25,35GFDXS25,35EARC433A8

Page 37: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Slim Concealed Ceiling Unit

! Slim design for fl exible installation! Compact dimensions, can easily be mounted in a

ceiling void! Blends unobtrusively with any interior décor! Can be installed in both new and existing

buildings.! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Powerful mode can be selected for rapid cooling

or heating! Home leave operation saves energy during

absence! Standard suction fi lter: removes airborne dust

particles to ensure a steady supply of clean air! Indoor / outdoor unit silent operation: "Silent"

buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .

! Medium external static pressure facilitates unit use with fl exible ducts of varying lengths

HEAT PUMP INVERTERIndoor UnitsIndoor Units FDXS50CVMB Capacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

5 steps standard

1.7

5.05.31.75.86.0

3.03 / 3.02825B / D

200x900x62027.0

12.0 / 11.0 / 10.0 / 8.412.0 / 11.0 / 10.0 / 8.4

55.055.0

37.0 / 35.0 / 33.0 / 31.037.0 / 35.0 / 33.0 / 31.0

R-410A1~/220-240/220-230V/50/60Hz

735x825x30048

-10~46-15~18

6244454848

R-410A1~/220-240V/50Hz

6.35 / 12.7/1830

FDXS-C / RXS-G

35

RXS50GFDXS50CARC433A8

Page 38: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Slim Concealed Ceiling Unit

! Slim design for fl exible installation! Compact dimensions, can easily be mounted in a

ceiling void! Blends unobtrusively with any interior décor! Can be installed in both new and existing

buildings.! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Powerful mode can be selected for rapid cooling

or heating! Home leave operation saves energy during

absence! Standard suction fi lter: removes airborne dust

particles to ensure a steady supply of clean air! Indoor / outdoor unit silent operation: "Silent"

buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .

! Medium external static pressure facilitates unit use with fl exible ducts of varying lengths

HEAT PUMPIndoor UnitsIndoor Units FDXS60CVMBCapacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kWStandard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

5 steps

standard

optional

1.76.0

6.5

1.77.0

8.0

2.82 / 3.02

1065

C / D

200x1100x62030.0

16.0 / 14.8 / 13.5 / 11.216.0 / 14.8 / 13.5 / 11.2

56.056.0

38.0 / 36.0 / 34.0 / 32.038.0 / 36.0 / 34.0 / 32.0

R-410A1~/220-240/220-230V/50/60Hz

735x825x30048

-10~46-15~18

63494946

R-410A1~/220-240/220-230V/50Hz

6.35 / 12.7 / 1830

FDXS-C / RXS-F

36

RXS60FFDXS60CARC433A8

MXS

Page 39: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

37

Page 40: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Lightweight and compact! Slim design for fl exible installation! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! The position of individual air discharge grilles

can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.

! Optimum air distribution! Quiet operation! Maximum external static pressure (ESP) is 88Pa

heat pump

optionalstandard

2 steps

35~50 optional

HEAT PUMP INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / HeatingAnnual energy consumption kWhEnergy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

ColourHxWxD mmWeight kg

Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBA

Sound Pressure (High) Cooling dBAHeating dBA

Refrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

FBQ35B8V1 FBQ50B8V1- -

3.4 5.0- -- -

4.0 6.0- -

2.91 2.60

585 960

C E300x700x800 300x700x800

30 3111.5 / 9 14 / 1011.5 / 9 14 / 10

52 5352 53

33 / 29 33 / 2933 / 29 33 / 29R-410A R-410A

1~/230V/50Hz 1~/230V/50HzBYBS45D BYBS45D

55x800x500 55x800x5003.5 3.5

RXS35G2V1B RXS50G2V1B550x765x285 735x825x300

34 48-10~46 -10~46-15~20 -15~20

63 6144 4445 45

48 4848 48

R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52 / 18 6.35 / 12.7 / 1820 30

FBQ-B / RXS-G

38

RXS35GFBQ35,50BBRC1D52

Page 41: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Lightweight and compact! Slim design for fl exible installation! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! The position of individual air discharge grilles

can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.

! Optimum air distribution! Quiet operation! Maximum external static pressure (ESP) is 88Pa

HEAT PUMP INVERTERIndoor UnitsIndoor Units FBQ60B8V1Capacity Cooling capacity Minimum kW

Standard kW

Maximum kWHeating capacity Minimum kW

Standard kW

Maximum kWEER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour WhiteHxWxD mmWeight kg

Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

standard heat pump

2 steps

60 optional

-5.7

--

7.0

-2.60 / 2.80

1095

E / E

300x1000x80041

19 / 1419 / 14

6060

34 / 3034 / 30R-410A

1~/230V/50HzBYBS71D

55x1100x5004.5

735x825x30048

-10~46-15~18

63494946

R-410A1~/220-240/220-230V/50Hz

6.35 / 12.7 / 1830

FBQ-B / RXS-F

39

RXS60FFBQ60BBRC1D52

Page 42: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Lightweight and compact! Slim design for fl exible installation! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! The position of individual air discharge grilles

can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.

! Optimum air distribution! Quiet operation! Maximum external static pressure (ESP) is 88Pa

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour WhiteHxWxD mmWeight kg

Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump optional

standard optional

2 steps

7.1 7.1 10.0 10.0 12.2

8.0 8.0 11.2 11.2 14.5

2.54 / 3.21 2.65 / 3.21 2.64 / 2.86 2.78 / 2.89 2.61 / 3.21

1395 1340 1895 1800 2335

E / C D / C D / D D / D D / C

300x1000x800 300x1400x80041.0 51.0 52.0

19.00 / 14.00 27.00 / 20.00 35.00 / 24.0019.00 / 14.00 27.00 / 20.00 35.00 / 24.00

60.0 62.0 63.034.0 / 30.0 36.0 / 31.0 38.0 / 32.034.0 / 30.0 36.0 / 31.0 38.0 / 32.0

R-410A1~/230V/50Hz

BYBS71DJW1 BYBS125DJW1

55x1100x500 55x1500x5004.5 6.5

770x900x320 1170x900x32084 83 103 101 108

-5.0~46.0-10.0~15.0

63.0 66.0 67.050.0 53.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26700.5

FBQ-B / RQ-B

40

RQ100, 125BFBQ100, 125BBRC1D52

Page 43: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Lightweight and compact! Slim design for fl exible installation! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! The position of individual air discharge grilles

can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.

! Optimum air distribution! Quiet operation! Maximum external static pressure (ESP) is 88Pa

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour WhiteHxWxD mmWeight kg

Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump optional

standard optional

2 steps

* Combination only available in Portugal, Greece, Cyprus and Malta

7.1 7.1 10 10 12.20

8 8 11.2 11.2 14.5

2.54 / 3.21 2.65 / 3.21 2.64 / 2.86 2.78 / 2.89 2.61 / 3.21

1395 1340 1895 1800 2335

E / C D / C D / D D / D D / C

300x1000x800 300x1400x80041.0 51.0 52.0

19.00 / 14.00 27.00 / 20.00 35.00 / 24.0019.00 / 14.00 27.00 / 20.00 35.00 / 24.00

60.0 62.0 63.034.0 / 30.0 36.0 / 31.0 38.0 / 32.034.0 / 30.0 36.0 / 31.0 38.0 / 32.0

R-410A1~/230V/50Hz

BYBS71DJW1 BYBS125DJW1

55x1100x500 55x1500x5004.5 6.5

770x900x320 1170x900x32083 102 100 108

10.0~46.0-10~15

65.0 70.053.0 57.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26500.5

FBQ-B/ REQ-B*

41

REQ100,125BFBQ100,125BBRC1D52

Page 44: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Lightweight and compact! Slim design for fl exible installation! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! The position of individual air discharge grilles

can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.

! Optimum air distribution! Quiet operation! Maximum external static pressure (ESP) is 88Pa

HEAT PUMP INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour WhiteHxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump

optional

standard

2 steps

optional

7.1 10.0 12.5 13.4

8.0 11.2 14.0 15.5

2.82 / 3.33 2.61 / 3.23 2.84 / 3.3 2.70 / 3.11

1,260 1,915 2,200 2,485

C / C D / C C / C D / D

300x1000x800 300x1400x80041.0 51.0 52.0

19.00 / 14.00 27.00 / 20.00 35.00 / 24.0019.00 / 14.00 27.00 / 20.00 35.00 / 24.00

60.0 62.0 63.034.0 / 30.0 36.0 / 31.0 38.0 / 32.034.0 / 30.0 36.0 / 31.0 38.0 / 32.0

R-410A1~/230V/50Hz

BYBS71DJW1 BYBS125DJW1

55x1100x500 55x1500x5004.5 6.5

770x900x320 700x900x320 1,170x900x320 1170x900x32068 103

-5~46-15~15.5

65 67 6849 51 5251 55 53 5447 49 50

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2630 50

0.5

FBQ-B / RZQS-C

42

RZQS125,140CBRC1D52 FBQ100,125,140B

Page 45: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Lightweight and compact! Slim design for fl exible installation! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! The position of individual air discharge grilles

can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.

! Optimum air distribution! Quiet operation! Maximum external static pressure (ESP) is 88Pa

HEAT PUMP INVERTERIndoor UnitsIndoor Units FBQ100B8V3B FBQ125B8V3B FBQ140B8V3BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour WhiteHxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump

optional

standard

2 steps

optional

10.00 12.50 13.40

11.20 14.00 15.50

3.50 / 3.73 3.14 / 3.51 2.82 / 3.21

1430 1990 2380

A / A B / B C / C

300x1400x80051.0 52.0

27.00 / 20.00 35.00 / 24.0027.00 / 20.00 35.00 / 24.00

62.0 63.036.0 / 31.0 38.0 / 32.036.0 / 31.0 38.0 / 32.0

R-410A1~/230V/50HzBYBS125DJW1

55x1500x5006.5

1345x900x320106

-15.0~50.0-20.0~15.5

65.0 66.049.0 50.051.0 52.0

45.0R-410A

3N~/400V/50Hz9.52 / 15.9 / 26

750.5

FBQ-B / RZQ-BW1

43

FBQ100,125,140B RZQ100,125,140BBRC1D52

Page 46: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! Maximum external static pressure (ESP) ranges

from 150 till 250Pa! Optimum air distribution

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min

Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA

Heating Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional

3 steps

optional heat pump

12.5

14.6

2.61 / 3.24

2395

D / C

350x1400x66259.043.043.075.044.044.0

R-410A1~/230V/50Hz

1170x900x320108

-5.0~46.0-10.0~15.0

67.053.0

R-410A3N~/400V/50Hz9.52 / 15.9 / 26

700.5

FDQ-B / RQ-B

44

RQ125BFDQ125BBRC1D52

Page 47: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! Maximum external static pressure (ESP) ranges

from 150 till 250Pa! Optimum air distribution

HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min

Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA

Heating Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQS125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional

3 steps standard

optional heat pump

12.5

14.0

2.81 / 3.43

2,225

C / B

350x1400x66259.043.043.075.044.044.0

R-410A1~/230V/50Hz

1,170x900x320103

-5~46-15~15.5

67515349

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 26500.5

FDQ-B / RZQS-C

45

RZQS125CFDQ125BBRC1D52

Page 48: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! Maximum external static pressure (ESP) ranges

from 150 till 250Pa! Optimum air distribution

HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min

Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA

Heating Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional

3 steps

optional standard heat pump

12.5

14.0

3.01 / 3.81

2075

B / A

350x1400x66259.043.043.075.044.044.0

R-410A1~/230V/50Hz

1170x900x320103

-15.0~50.0-20.0~15.5

66505245

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 26750.5

FDQ-B / RZQ-C

46

RZQ125CFDQ-BBRC1D52

Page 49: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! Maximum external static pressure (ESP) ranges

from 150 till 250Pa! Optimum air distribution

HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min

Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA

Heating Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional

3 steps heat pump

optional standard

12.50

14.00

3.01 / 3.79

2075

B / A

350x1400x66259.043.043.075.044.044.0

R-410A1~/230V/50Hz

1345x900x320106

-15.0~50.0-20.0~15.5

66.050.052.045.0

R-410A3N~/400V/50Hz9.52 / 15.9 / 26

750.5

FDQ-B / RZQ-BW1

47

RZQ125BFDQ-BBRC1D52

Page 50: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

48

Page 51: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Lightweight and compact! Both discharge and suction ducts can be easily

connected via fl anges on the unit! The air fi lter is easily accessible from underneath,

even after the installation of the ducts. The fi lter can therefore be easily washed or vacuumed

! Extremely quiet in operation.! Ideal for shops, restaurants or offi ces requiring

maximum fl oor space for furniture, decorations and fi ttings

! Maximum external static pressure (ESP) is 100Pa

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDEQ71B8V3B FDEQ100B8V3B FDEQ125B8V3BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m* Combination only available in Portugal, Greece, Cyprus and Malta

(optional) (3 steps)

heat pump

7.1 7.1 9.8 9.8 12.50

8 8 11.2 11.2 14.60

2.54 / 3.21 2.65 / 3.21 2.46 / 2.81 2.49 / 2.83 2.68 / 3.23

1395 1340 1990 1970 2335

E / C D / C E / D E / D D / C

279x987x750 279x1387x75038.1 48.6

19.0 / 14.0 27.0 / 20.0 35.0 / 24.019.0 / 14.0 27.0 / 20.0 35.0 / 24.0

63.0 65.0 66.037.0 / 33.0 39.0 / 34.0 41.0 / 35.037.0 / 33.0 39.0 / 34.0 41.0 / 35.0

R-410A1~/230V/50Hz

770x900x320 1170x900x32083 102 100 108

10.0~46.0-10~15

65.0 70.053.0 57.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26500.5

FDEQ-B / REQ-B*

49

REQ100BFDEQ125BBRC1D52

Page 52: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Reduced installation height: 214mm for class

35-50! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB Capacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / heating

Annual energy consumption kWh

Energy label Cooling / heatingDimensions (Height x width x depth) mmWeight kgAir fl ow rate Cooling High/low m³/min

Heating High/low m³/minSound power Cooling High dBASound pressure Cooling High/low dBA

Heating High/low dBARefrigerant TypePower supplyDecoration panel Model

Colour Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RXS35G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

heat pump

optional

2 steps optional

optional standard

1.4 0.93.4 5.03.7 5.61.4 0.94.2 6.05.0 7.0

3.58/3.41 3.55/3.70475 705

A/B A204x840x840 204x840x840

19 1910.5 / 8.5 12.5 / 8.5

12.5 / 10.0 12.5 / 8.549 49

31 / 27 31 / 2731 / 27 31 / 27R-410A R-410A

1~/220-240V/50/60Hz 1~/220-240V/50/60HzBYCQ140CW1 BYCQ140CW1

50x950x950 50x950x9505.5 5.5

550x765x285 735x825x30034 48

-10~46 -10~46-15~20 -15~20

63 6144 4445 4548 4848 48

R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52/18 6.35 / 12.7/1820 30

FCQ-C / RXS-G

50

RXS35GFCQ35,50C BRC1D52 BRC7E63

Page 53: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Reduced installation height: 214mm for class 60! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ60C7VEBCapacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kW

Standard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional heat pump

2 steps optional

optional standard

0.95.7

6.0

0.97.0

8.0

3.48 / 3.52

820

A / B

204x840x84019

13.5 / 8.513.5 / 8.5

5133 / 2833 / 28R-410A

1~/220-240V/50/60HzBYCQ140CW1

50x950x9505.5

735x825x30048

-10~46-15~18

63494946

R-410A1~/220-240/220-230V/50Hz

6.35 / 12.7 / 1830

FCQ-C / RXS-F

51

RXS60F FCQ60C BRC1D52 BRC7F532

Page 54: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Fresh air intake: up to 20 %! Reduced installation height: 214mm for class 71! Easy visible drain check thanks to clear drain socket

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEBCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump

optional optional

2 steps optional

standard

7.1 7.1 10.0 10.0 12.5

8.0 8.0 11.2 11.2 14.6

2.61 / 2.81 2.67 / 2.86 2.61 / 2.99 2.81 / 3.06 2.68 / 2.89

1360 1330 1915 1780 2330

D / D D / D D / D C / D D / D

204x840x840 246x840x84021 23

15.5 / 9.0 23.5 / 16.0 27.5 / 19.016.0 / 9.5 23.5 / 16.0 27.5 / 19.0

51 54 5833 / 28 37 / 32 41 / 3534 / 28 37 / 32 41 / 35

R-410A1~/220-240V/50/60Hz

BYCQ140CW1

50x950x9505.5

770x900x320 1170x900x32084 83 103 101 108

-5.0~46.0-10.0~15.0

63.0 66.0 67.050.0 53.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26700.5

FCQ-C / RQ-B

52

RQ100BFCQ100,125C BRC1D52 BRC7F532

Page 55: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Fresh air intake: up to 20 %! Reduced installation height: 214mm for class 71! Easy visible drain check thanks to clear drain socket

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEBNominal Capacity Cooling capacity Standard kW 7.1 7.1 10.0 10.0 12.5

Heating capacity Standard kW 8.0 8.0 11.2 11.2 14.6

EER / COP Cooling / Heating 2.61 / 2.81 2.67 / 2.86 2.61 / 2.99 2.81 / 3.06 2.68 / 2.89

Annual energy consumption kWh 1360 1330 1915 1780 2330

Energy Label cooling / heating D / D D / D C / D D / D

Dimensions (Height x Width x Depth) mm 204x840x840 246x840x840 246x840x840Weight kg 21 23 23Air Flow Rate Cooling High/Low m³/min 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0

Heating High/Low m³/min 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0Sound Power Cooling High dBA 51 54 58Sound Pressure Cooling High/Low dBA 33 / 28 37 / 32 41 / 35

Heating High/Low dBA 34 / 28 37 / 32 41 / 35Refrigerant Type R-410A R-410A R-410APower Supply 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz 1~/220-240V/50/60HzDecoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1

Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mm 50x950x950 50x950x950 50x950x950

Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mm 770x900x320 1170x900x320Weight kg 83 102 100 108Sound pressure level Cooling dBA 53 53 57 57 57Sound power level Cooling dBA 65 65 70 70 70Operation Range Cooling Min~Max °CDB 10.0~46.0

Heating Min~Max °CWB -10~15Refrigerant Type R-410APower Supply 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50HzPiping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26Piping Length (Maximum) m 50Max. internunit level difference m 0.5* Combination only available in Portugal, Greece, Cyprus and Malta

heat pump

optional

2 steps optional

optional

standard

53

FCQ-C / REQ-B*

REQ100,125BBRC7F532 FCQ100,125CBRC1D52

Page 56: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Reduced installation height: 214mm for class 71! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEBCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pumpoptional

2 steps optional

optional standard

7.1 10.0 12.5 14.0

8.0 11.2 14.0 16.0

2.89 / 3.07 2.61 / 3.23 3.02 / 3.1 2.61 / 2.81

1,230 1,915 2,070 2,680

C / D D / C B / D D / D

204x840x840 246x840x84021 23

15.5 / 9.0 23.5 / 16.0 27.5 / 19.016.0 / 9.5 23.5 / 16.0 27.5 / 19.0

51 54 5833 / 28 37 / 32 41 / 3534 / 28 37 / 32 41 / 35 42 / 35

R-410A1~/220-240V/50/60Hz

BYCQ140CW1

50x950x9505.5

770x900x320 700x900x320 1,170x900x320 1170x900x32068 103

-5~46-15~15.5

65 67 6849 51 5251 55 53 5447 49 50

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2630 50

0.5

FCQ-C / RZQS-C

54

RZQS125,140CFCQ100,125,140C BRC1D52 BRC7E63

Page 57: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Reduced installation height: 214mm for class 71! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEBCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pumpoptional

2 steps optional

optional standard

7.1 10.0 12.5 14.0

8.0 11.2 14.0 16.0

3.36 / 3.62 3.61 / 3.71 3.22 / 3.54 2.61 / 3.21

1,055 1385 1940 2680

A / A A / B D / C

204x840x840 246x840x84021 23

15.5 / 9.0 23.5 / 16.0 27.5 / 19.016.0 / 9.5 23.5 / 16.0 27.5 / 19.0

51 54 5833 / 28 37 / 32 41 / 3534 / 28 37 / 32 41 / 35 42 / 35

R-410A1~/220-240V/50/60Hz

BYCQ140CW1

50x950x9505.5

770x900x320 1170x900x32067 103

-15.0~50.0-20.0~15.5

63 65 66 6747 49 5049 51 5243 45 46

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2650 75

0.5

FCQ-C / RZQ-C

55

RZQ100,125,140CFCQ71C BRC1D52 BRC7E63

Page 58: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ100C7VEB FCQ125C7VEB FCQ140C7VEBCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pumpoptional

2 steps optional

optional standard

10.0 12.50 14.00

11.20 14.00 16.00

3.79 / 3.57 3.22 / 3.21 2.61 / 2.81

1320 1940 2680

A / B A / C D / D

246x840x84023

23.5 / 16.0 27.5 / 19.023.5 / 16.0 27.5 / 19.0

54 5837 / 32 41 / 3537 / 32 41 / 35 42 / 35

R-410A1~/220-240V/50/60Hz

BYCQ140CW1

50x950x9505.5

1345x900x320106

-15.0~50.0-20.0~15.5

65.0 66.049.0 50.051.0 52.0

45.0R-410A

3N~/400V/50Hz9.52 / 15.9 / 26

750.5

FCQ-C / RZQ-BW1

56

RZQ100,125,140BFCQ100,125,140C BRC1D52 BRC7E63

Page 59: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Improved operating effi ciency! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEBCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pumpoptional

2 steps optional

optional standard

7.1 10.0 12.5 14.0

8.0 11.2 14.0 16.0

3.01 / 3.41 2.81 / 3.41 3.22 / 3.41 2.81 / 3.21

1,180 1,780 1,940 2,490

B / B C / B A / B C / C

246x840x840 288x840x84023 25

20.0 / 12.0 32.5 / 18.0 32.5 / 21.520.0 / 12.0 32.5 / 18.0 32.5 / 21.5

52 6034 / 28 43 / 32 43 / 36 43 / 3834 / 28 43 / 32 43 / 36 43 / 38

R-410A1~/220-240V/50/60Hz

BYCQ140CW1

50x950x9505.5

770x900x320 700x900x320 1,170x900x320 1170x900x32068 103

-5~46-15~15.5

65 67 6849 51 5251 55 53 5447 49 50

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2630 50

0.5

FCQH-C / RZQS-C

57

RZQS125,140CFCQH100,125,140C BRC1D52 BRC7F532

Page 60: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Improved operating effi ciency! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEBCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pumpoptional

2 steps optional

optional standard

7.1 10.0 12.5 14.0

8.0 11.2 14.0 16.0

3.59 / 4.06 3.76 / 4.39 3.38 / 3.92 3.02 / 3.61

990 1330 1850 2320

A / A B / A

246x840x840 288x840x84023 25

20.0 / 12.0 32.5 / 18.0 32.5 / 21.520.0 / 12.0 32.5 / 18.0 32.5 / 21.5

52 6034 / 28 43 / 32 43 / 36 43 / 3834 / 28 43 / 32 43 / 36 43 / 38

R-410A1~/220-240V/50/60Hz

BYCQ140CW1

50x950x9505.5

770x900x320 1170x900x32067 103

-15.0~50.0-20.0~15.5

63 65 66 6747 49 5049 51 5243 45 46

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2650 75

0.5

FCQH-C / RZQ-C

58

FCQH100,125,140C BRC1D52 BRC7F532 RZQ100,125,140C

Page 61: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Round Flow Cassette

! Improved operating effi ciency! Modern style decoration panel in white (RAL9010)! 360° air discharge ensures uniform air fl ow and

temperature distribution! Air discharge from the corners avoids dead zones

that may be subject to temperature differences! Comfortable horizontal air discharge ensures

draughtfree operation and prevents ceiling soiling! 23 different air fl ow patterns possible! Fresh air intake: up to 20 %! Easy visible drain check thanks to clear drain socket

HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQH100C7VEB FCQH125C7VEB FCQH140C7VEBCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pumpoptional

2 steps optional

optional standard

10.00 12.50 14.00

11.20 14.00 16.00

4.10 / 4.38 3.53 / 3.90 3.01 / 3.54

1220 1770 2325

A / A B / B

288x840x84025

32.5 / 18.0 32.5 / 21.532.5 / 18.0 32.5 / 21.5

6043 / 32 43 / 36 43 / 3843 / 32 43 / 36 43 / 38

R-410A1~/220-240V/50/60Hz

BYCQ140CW1

50x950x9505.5

1345x900x320106

-15.0~50.0-20.0~15.5

65.0 66.049.0 50.051.0 52.0

45.0R-410A

3N~/400V/50Hz9.52 / 15.9 / 26

750.5

FCQH-C / RZQ-BW1

59

RZQ100,125,140BFCQH100,125,140C BRC1D52 BRC7F532

Page 62: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

4-Way Blow Ceiling Mounted Cassette (600mm x 600mm)

! New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles

! Modern style decoration panel in white (RAL9010)

! Slim design for fl exible installation! Ideal for shops, restaurants or offi ces requiring

maximum fl oor space for furniture, decorations and fi ttings

! Extremely quiet in operation! Possibility to shut 1 or 2 fl aps for easy

installation in corners! Auto-swing function ensures effi cient air and

temperature distribution and prevents ceiling soiling.

! Excellent low draught characteristics! Easy installation and maintenance

! The switch box can be reached by simply removing the suction grille; therefore maintenance can be done very easily.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B Capacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RXS25G2V1B RXS35G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

heat pump

optional standard

2 steps optionaloptional

- - -2.5 3.4 4.7- - -- - -

3.2 4.0 5.5- - -

3.42/3.48 3.09/3.33 2.61/2.81

365 550 900

A/B B/C D286x575x575 286x575x575 286x575x575

17.5 17.5 17.59.0 / 6.5 10.0 / 6.5 12.0 / 8.09.0 / 6.5 10.0 / 6.5 12.0 / 8.0

46.5 49.0 53.029.5 / 24.5 32.0 / 25.0 36.0 / 27.029.5 / 24.5 32.0 / 25.0 36.0 / 27.0

R-410A R-410A R-410A1~/230V/50Hz 1~/230V/50Hz 1~/230V/50HzBYFQ60BAW1 BYFQ60BAW1 BYFQ60BAW1

55x700x700 55x700x700 55x700x7002.7 2.7 2.7

550x765x285 550x765x285 735x825x30034 34 48

-10~46 -10~46 -10~46-15~20 -15~20 -15~20

61 63 6143 44 4444 45 4546 48 4847 48 48

R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz

6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 30

FFQ-B / RXS-G

60

RXS25,35GFFQ-B BRC1D52 BRC7E531

Page 63: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

4-way Blow Ceiling Mounted Cassette (600mm x 600mm)

! New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles

! Modern style decoration panel in white (RAL9010)! Slim design for fl exible installation! Ideal for shops, restaurants or offi ces requiring

maximum fl oor space for furniture, decorations and fi ttings

! Extremely quiet in operation! Possibility to shut 1 or 2 fl aps for easy installation

in corners! Auto-swing function ensures effi cient air and

temperature distribution and prevents ceiling soiling.

! Excellent low draught characteristics! Easy installation and maintenance! The switch box can be reached by simply

removing the suction grille; therefore maintenance can be done very easily.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FFQ60B8V1BCapacityCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label Cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model

Colour Pure White (RAL 9010)HxWxD mmWeight kg

Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional standard heat pump

2 steps optional

optional

5.8

7.0

2.80 / 2.81

1035

D / D

286x575x57517.5

15.0 / 10.015.0 / 10.0

58.041.0 / 32.041.0 / 32.0

R-410A1~/230V/50HzBYFQ60BAW1

55x700x7002.7

735x825x30048

-10~46-15~18

63494946

R-410A1~/220-240/220-230V/50Hz

6.35 / 12.7 / 1830

FFQ-B / RXS-F

61

RXS60FFFQ60B BRC1D52 BRC7E531

Page 64: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

4-Way Blow Ceiling Suspended Cassette

! Can be installed in both new and existing buildings.

! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings

! Air can be discharged in any of 4 directions! Air fl ow distribution for ceiling heights up to 3.5m

without loss of capacity.! No ceiling staining! Possibility to shut 1 or 2 fl aps for easy installation

in corners! Air fi lter, drain pan and heat exchanger fi n are

mildew proof and anti-bacterial treated.! Drain-up pump with 500mm lift fi tted as standard! Easy to install

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump optional

standard optional

2 steps optional

7.1 7.1 10.0 10.0 12.2

8.0 8.0 11.2 11.2 14.5

2.63 / 3.16 2.68 / 3.28 2.61 / 3.13 2.65 / 3.16 2.67 / 2.97

1350 1325 1915 1890 2285

D / D D / C D / D D / D D / D

165x895x895 230x895x89525.0 31.0

19.0 / 14.0 29.0 / 21.0 32.0 / 23.019.0 / 14.0 29.0 / 21.0 32.0 / 23.056.0 / 51.0 59.0 / 54.0 60.0 / 55.056.0 / 51.0 59.0 / 54.0 60.0 / 55.040.0 / 35.0 43.0 / 38.0 44.0 / 39.040.0 / 35.0 43.0 / 38.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32084 83 103 101 108

-5.0~46.0-10.0~15.0

63.0 66.0 67.050.0 53.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26700.5

FUQ-B / RQ-B

62

RQ100BFUQ71B BRC1D52 BRC7C529

Page 65: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

4-Way Blow Ceiling Suspended Cassette

! Can be installed in both new and existing buildings.

! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings

! Air can be discharged in any of 4 directions! Air fl ow distribution for ceiling heights up to 3.5m

without loss of capacity.! No ceiling staining! Possibility to shut 1 or 2 fl aps for easy installation

in corners! Air fi lter, drain pan and heat exchanger fi n are

mildew proof and anti-bacterial treated.! Drain-up pump with 500mm lift fi tted as standard! Easy to install

HEAT PUMP INVERTERIndoor UnitsIndoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump

optional

standard

2 steps optional

optional

7.1 10 12.5

8.0 11.2 14.0

3.21 / 3.42 3.21 / 3.32 3.01 / 3.23

1,105 1560 2075

A / B A / C B / C

165x895x895 230x895x89525.0 31.0

19.0 / 14.0 29.0 / 21.0 32.0 / 23.019.0 / 14.0 29.0 / 21.0 32.0 / 23.056.0 / 51.0 59.0 / 54.0 60.0 / 55.056.0 / 51.0 59.0 / 54.0 60.0 / 55.040.0 / 35.0 43.0 / 38.0 44.0 / 39.040.0 / 35.0 43.0 / 38.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32067 103

-15.0~50.0-20.0~15.5

63 65 6647 49 5049 51 5243 45

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2650 75

0.5

FUQ-B / RZQ-C

FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B

RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B

63

FUQ-B BRC1D52 BRC7C529 RZQ100,125C

Page 66: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

4-Way Blow Ceiling Suspended Cassette

! Can be installed in both new and existing buildings.

! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings

! Air can be discharged in any of 4 directions! Air fl ow distribution for ceiling heights up to 3.5m

without loss of capacity.! No ceiling staining! Possibility to shut 1 or 2 fl aps for easy installation

in corners! Air fi lter, drain pan and heat exchanger fi n are

mildew proof and anti-bacterial treated.! Drain-up pump with 500mm lift fi tted as standard! Easy to install

HEAT PUMP INVERTERIndoor UnitsIndoor Units FUQ100BVV1B FUQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump

optionalstandard

2 steps optional

optional

10.00 12.50

11.20 14.00

3.21 / 3.41 3.09 / 3.21

1560 2025

A / B B / C

230x895x89531.0

29.0 / 21.0 32.0 / 23.029.0 / 21.0 32.0 / 23.059.0 / 54.0 60.0 / 55.059.0 / 54.0 60.0 / 55.043.0 / 38.0 44.0 / 39.043.0 / 38.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

1345x900x320106

-15.0~50.0-20.0~15.5

65.0 66.049.0 50.051.0 52.0

45.0R-410A

3N~/400V/50Hz9.52 / 15.9 / 26

750.5

FUQ-B / RZQ-BW1

64

RZQ100,125BFUQ-B BRC1D52 BRC7C529

Page 67: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Ceiling Suspended Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Compact design! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Easy installation and maintenance! Auto-swing function ensures effi cient air and

temperature distribution.! Air fl ow distribution for ceiling heights up to 3.8m

without loss of capacity.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1BCapacity Cooling capacity Minimum kW

Standard kWMaximum kW

Heating capacity Minimum kWStandard kWMaximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label Cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS35G2V1B RXS50G2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

heat pump 2 steps

optional

35~50 optionaloptional optional

1.4 1.73.4 5.03.7 5.61.2 1.74.0 6.05.0 7.0

3.24 / 3.60 2.73 / 2.93

525 915

A / A D / C195x960x680 195x960x680

24.0 25.013.0 / 10.0 13.0 / 10.013.0 / 10.0 13.0 / 10.053.0 / 48.0 54.0 / 49.053.0 / 48.0 54.0 / 49.037.0 / 32.0 38.0 / 33.037.0 / 32.0 38.0 / 33.0

R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz

550x765x285 735x825x30034 48

-10~46 -10~46-15~20 -15~20

63 6144 4445 4548 4848 48

R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz6.35 / 9.52 / 18 6.35 / 12.7 / 18

20 30

FHQ-B / RXS-G

65

RXS35GFHQ-B BRC1D52 BRC7E66

Page 68: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Ceiling Suspended Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Compact design! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Easy installation and maintenance! Auto-swing function ensures effi cient air and

temperature distribution.! Air fl ow distribution for ceiling heights up to 3.8m

without loss of capacity.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ60BVV1BCapacity Cooling capacity Minimum kW

Standard kW

Maximum kW

Heating capacity Minimum kW

Standard kW

Maximum kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label Cooling / Heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

heat pump 2 steps optional

optional optional optional

1.75.7

6.0

1.7

7.2

8.0

2.65 / 2.89

1075

D / D195x1160x680

27.017.0 / 13.016.0 / 13.055.0 / 49.055.0 / 49.039.0 / 33.039.0 / 33.0

R-410A1~/220-240V/50Hz

735x825x30048

-10~46-15~18

63494946

R-410A1~/220-240/220-230V/50Hz

6.35 / 12.7 / 1830

FHQ-B / RXS-F

66

RXS60FFHQ60B BRC1D52 BRC7E63

60

Page 69: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Ceiling Suspended Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Compact design! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Easy installation and maintenance! Auto-swing function ensures effi cient air and

temperature distribution.! Air fl ow distribution for ceiling heights up to 3.8m

without loss of capacity.

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

optional optional 2 steps optional

optional

7.1 7.1 9.8 9.8 12.2

8.0 8.0 11.2 11.2 14.5

2.63 / 2.81 2.68 / 2.86 2.61 / 2.71 2.66 / 2.79 2.71 / 2.81

1350 1325 1875 1840 2255

D / D D / D D / E D / E D / D

195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0

17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32084 83 103 101 108

-5.0~46.0-10.0~15.0

63.0 66.0 67.050.0 53.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26700.5

FHQ-B / RQ-B

67

RQ100BFHQ71B BRC1D52 BRC7E63

Page 70: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Ceiling Suspended Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Compact design! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Easy installation and maintenance! Auto-swing function ensures effi cient air and

temperature distribution.! Air fl ow distribution for ceiling heights up to 3.8m

without loss of capacity.

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m* Combination only available in Portugal, Greece, Cyprus and Malta

optional heat pump 2 steps optional

optional

optional

7.1 7.1 9.8 9.8 12.2

8 8 11.2 11.2 14.5

2.63 / 2.81 2.68 / 2.86 2.61 / 2.71 2.66 / 2.79 2.71 / 2.81

1350 1325 1875 1840 2255

D / D D / D D / E D / E D / D

195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0

17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32083 102 100 108

10.0~46.0-10~15

65.0 70.053.0 57.0

R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz

9.52 / 15.9 / 26500.5

FHQ-B / REQ-B*

68

FHQ71B BRC1D52 BRC7E66 REQ71B

Page 71: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Ceiling Suspended Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Compact design! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Easy installation and maintenance! Auto-swing function ensures effi cient air and

temperature distribution.! Air fl ow distribution for ceiling heights up to 3.8m

without loss of capacity.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump 2 steps

optional

optional optionaloptional

7.1 10.0 12.5

8.0 11.2 14.0

2.81 / 2.81 2.41 / 2.81 2.73 / 2.82

1,265 2,075 2,290

C / D E / D D / D

195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0

17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

770x900x320 700x900x320 1,170x900x32068 103

-5~46-15~15.5

65 6749 5151 55 5347 49

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2630 50

0.5

FHQ-B / RZQS-C

69

RZQS100,125CFHQ71B BRC1D52 BRC7E63

Page 72: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Ceiling Suspended Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Compact design! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Easy installation and maintenance! Auto-swing function ensures effi cient air and

temperature distribution.! Air fl ow distribution for ceiling heights up to 3.8m

without loss of capacity.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump 2 steps

optional

optional optionaloptional

7.1 10.0 12.5

8.0 11.2 14.0

2.89 / 3.00 3.03 / 3.21 2.81 / 3.21

1,230 1650 2225

C / D B / C C / C

195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0

17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32067 103

-15.0~50.0-20.0~15.5

63 65 6647 49 5049 51 5243 45

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2650 75

0.5

FHQ-B / RZQ-C

70

BRC1D52 BRC7E63 FHQ71B RZQ100,125C

Page 73: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Ceiling Suspended Unit

! Ideal solution for shops, restaurants or offi ces without false ceilings

! Compact design! Leaves maximum fl oor and wall space for

furniture, decorations and fi ttings! Easy installation and maintenance! Auto-swing function ensures effi cient air and

temperature distribution.! Air fl ow distribution for ceiling heights up to 3.8m

without loss of capacity.

HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

heat pump 2 steps

optional

optional optionaloptional

10.00 12.50

11.20 14.00

3.17 / 3.11 2.81 / 3.11

1575 2225

B / D C / D

195x1400x680 195x1590x68032.0 35.0

24.0 / 20.0 30.0 / 25.024.0 / 20.0 30.0 / 25.058.0 / 53.0 60.0 / 55.058.0 / 53.0 60.0 / 55.042.0 / 37.0 44.0 / 39.042.0 / 37.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

1345x900x320106

-15.0~50.0-20.0~15.5

65.0 66.049.0 50.051.0 52.0

45.0R-410A

3N~/400V/50Hz9.52 / 15.9 / 26

750.5

FHQ-B / RZQ-BW1

71

RZQ100,125BFHQ-B BRC1D52 BRC7E63

Page 74: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

72

Page 75: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

73

PACKAGED SYSTEMSFDQ-B / RZQ-C 74FDYP-B / RYP-B 75FDYB-C / RY-C 76FDYM-C / RY-C 78

ROOF TOP UNITSUATYP-A 80UATY-A 81

A range of high performance, low energy consumption air

cooled packaged roof top units is produced by Daikin for

supermarket, warehouse, factory, hotel, hospital, cinema and

large store applications.

Heat pump ‘plug and play’ versions are easy to install and

available as fully integrated systems comprising compressor,

evaporator and condensing units for air transmission through

ductwork to the conditioned space.

Roof Top & Packaged Systems

Page 76: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor: only

the suction and discharge grilles are visible! Maximum external static pressure (ESP) ranges

from 150 till 250Pa! Optimum air distribution

HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ200B8V3B9 FDQ250B8V3B9Capacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min

Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA

Heating Low dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RZQ200C7Y1B RZQ250C7Y1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound power dBASound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m

heat pump

optional

2 steps: FDQ250, 3 steps: FDQ200

optional

standard

20.0 24.1

23.0 26.4

3.21 / 3.41 2.81 / 3.21

3.115 4.290A / B C / C

450x1400x90089.0 94.069.0 89.069.0 89.081.0 82.045.0 47.045.0 47.0

R-410A1~/230V/50Hz

1680x930x765183 184

-5.0~46.0-15.0~15.0

7857

R-410A3N~/380-415V/50Hz

9.5 / 22,2100

FDQ-B / RZQ-CY1

74

RZQ200,250CFDQ200,250BBRC1D52

Page 77: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Slim design for fl exible installation! Ideal for use in larger areas! Blends unobtrusively with any interior décor! Maximum external static pressure (ESP) ranges

from 150 till 250Pa! Optimum air distribution

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYP200B8V19 FDYP250B8V19Capacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / HeatingAnnual energy consumption kWhDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min

Heating Medium m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High dBA

Heating High dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RYP200B7W1 RYP250B7W1Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m

optional

2 steps: FDYP250, 3 steps: FDYP200

twin application only

heat pump

optional

19.50 25.00

23.10 27.00

2.24/3.04 2.45/3.084.345 5.100

450x1400x90089.0 94.069.0 89.069.0 89.081.0 82.081.0 82.045.0 47.045.0 47.0

R-407C230V/50Hz

1220x1290x700 1440x1290x700196 210

-5~46-10~15

77.057.057.0

R-407C400V/50Hz

12.7 / 28.6 / 26 15.9 / 28.6 / 2650

FDYP-B / RYP-B

75

RYP250BFDYP200,250BBRC1D52

Page 78: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings

! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure

save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYB30CV1M FDYB40CV1M FDYB60CV1M FDYB71CV1M FDYB90CV1M FDYB125CV1MCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min

SH/H/M/L m³/minSound Power Cooling High/Medium/Low dBA

SH/H/M/L dBASound Pressure Cooling High/Medium/Low dBA

SH/H/M/L dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RY30CV1M RY40CV1M RY60CV1M RY71CV1M RY80CV1M RY90CV1M RY100CV1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m

standard heat pump

4 steps

2.782 3.605 5.570 6.740 8.602 8.792 9.818

2.782 3.515 5.800 7.330 8.499 8.792 10.257

3.18 / 3.31 2.95 / 3.31 3.03 / 3.32 2.95 / 3.24 2.75 / 3.15 2.82 / 2.85 3.06 / 3.20

438 611 919 1,143 1,562 1,558 1,605

B / C C / C B / C C / C D/D C/D B/D

261x765x411 261x1,065x411 261x1,200x411 378x929x541 378x1,045x54117 21 22 25 39 42

7.62 / 7.08 / 5.94 15.3 / 13.32 / 9.9 18.42 / 18.18 / 16.14 21.78 / 20.4 / 16.44 - -- 20.64 / 24.9 / 22.38 / 20.94 33.72 / 30.00 / 28.32 / 27.48

57 / 54 / 51 61 / 58 / 52 65 / 64 / 60 66 / 64 / 61 - -- 76 / 73 / 69 / 64 78 / 76 / 72 / 68

33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 - -- 49 / 46 / 42 / 38 51 / 49 / 45 / 41

R-221~/220-240V/50Hz

540x700x250 648x855x328 750x855x328 850x1,030x40032 59 62 68 95

19.0~46.0-9.0~18.0

46 49 51 52 54 58R-22

1~/220-240V/50Hz6.35 / 9.52 6.35 / 12.7 6.35 / 15.9 9.52 / 15.9 9.52 / 19.1

12 15 45

FDYB-C / RY-C

76

FDYB-CSLM3 RY-CV1M

Page 79: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings

! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure

save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYB90CV1M FDYB125CV1M FDYB140CV1M FDYB160CV1MCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling SH/H/M/L m³/minSound Power Cooling SH/H/M/L dBASound Pressure Cooling SH/H/M/L dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RY90CY1M RY125CY1M RY140CY1M RY160CY1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m

standard heat pump

4 steps

8.792 11.723 14.654 16.410

8.792 11.723 15.533 16.410

2.84 / 2.87 3.22 / 3.50 2.89 / 3.47 2.79 / 3.38

1,548 1,822 2,535 2,942

C / D A / B C / B D / C

378x929x541 378x1,045x541 378x1,299x541 378x1,499x54139 42 54 62

26.64 / 24.9 / 22.38 / 20.94 33.72 / 30.00 / 28.32 / 27.48 42.78 / 37.68 / 37.08 / 35.94 48.12 / 45.90 / 43.02 / 41.5876 / 73 / 69 / 64 78 / 76 / 72 / 68 78 / 76 / 73 / 70 79 / 78 / 75 / 7149 / 46 / 42 / 38 51 / 49 / 45 / 41 53 / 52 / 50 / 47 55 / 53 / 50 / 47

R-221~/220-240V/50Hz

850x1,030x40095 100 105 108

19.0~46.0-9.0~18.0

58 61R-22

3~/380-415V/50Hz9.52 / 15.9 9.52 / 19.1 12.7 / 19.1

45 35

FDYB-C / RY-CY

77

FDYB-CSLM3 RY-CY1M

Page 80: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings

! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure

save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYM30CV1M FDYM40CV1M FDYM60CV1M FDYM71CV1M FDYM80CV1M FDYM90CV1M FDYM100CV1M FDYM125CV1MCapacity Cooling capacity Standard kW

Heating capacity Standard kW

EER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min

SH/H/M/L m³/minSound Power Cooling High/Medium/Low dBA

SH/H/M/L dBASound Pressure Cooling High/Medium/Low dBA

SH/H/M/L dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RY30CV1M RY40CV1M RY60CV1M RY71CV1M RY80CV1M RY90CV1M RY100CV1M RY125CV1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m

standard heat pump

4 steps

2.780 3.600 5.570 6.890 7.913 8.792 8.602 8.792 10.257 9.818 9.818 11.723

2.780 3.600 5.800 7.030 8.206 8.792 8.499 8.792 10.550 10.257 10.257 11.723

3.09 / 3.52 2.84 / 3.39 2.94 / 3.14 2.63 / 2.77 2.56 / 3.11 2.85 / 2.87 2.73 / 3.11 2.80 / 2.82 3.11 / 3.19 30.1 / 3.14 30.1 / 3.14 3.14 / 3.62

450 634 948 1,308 1,546 1,545 1,577 1,573 1,652 1,633 1,633 1,864

B / B C / C C / D D / E E / D C / D D / D D / D B / D B / D B / D B / A

261x765x411 261x905x411 261x1,065x411 261x1,200x411 285x1,007x600 378x929x541 305x1,302x638 378x1,045x54117 21 22 25 38 39 41 42

8.52 / 7.38 / 6.24 14.46 / 12.48 / 10.20 18.96 / 18.12 / 16.68 18.96 / 21.54 / 16.68 -- 24.06 / 22.92 / 21.78 / 20.10 25.50 / 23.52 / 21.54 / 20.10 43.62 / 41.64 / 40.20 / 38.22 31.14 / 30.00 / 28.02 / 25.50

57 / 54 / 51 61 / 58 / 52 65 / 64 / 60 66 / 64 / 61 -- 67 / 64 / 61 / 57 76 / 73 / 69 / 64 80 / 76 / 73 / 70 78 / 76 / 72 / 68

33 / 20 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 -- 44 / 41 / 38 / 34 49 / 46 / 42 / 38 55 / 51 / 48 / 45 51 / 49 / 45 / 41

R-221~/220-240V/50Hz

540x700x250 648x855x328 750x855x328 850x1,030x40032 59 62 68 95 100

19.0~46.0-9.0~18.0

46 49 51 52 54 58R-22

1~/220-240V/50Hz6.35 / 9.52 6.35 / 12.7 6.35 / 15.9 9.52 / 15.9 9.52 / 19.1

12 15 45

FDYM-C / RY-C

78

FDYM-CSLM3 RY-CV1M

Page 81: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Concealed Ceiling Unit

! Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

! Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings

! Double protection drainage system! Slim design for fl exible installation! Compact indoor models and twin coil structure

save installation space! Easy operation and maintenance! Multiple rooms conditioned via single fan coil unit! Fresh air intake for healthy living! Superior air distribution for comfortable living

HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYM80CV1M FDYM90CV1M FDYM100CV1M FDYM125CV1M FDYM140CV1M FDYM160CV1MCapacity Cooling capacity Standard kW

Heating capacity Standard kWEER / COP Cooling / Heating

Annual energy consumption kWh

Energy Label cooling / heating

Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min

SH/H/M/L m³/minSound Power Cooling High/Medium/Low dBA

SH/H/M/L dBASound Pressure Cooling High/Medium/Low dBA

SH/H/M/L dBARefrigerant TypePower Supply

Outdoor UnitOutdoor Unit RY90CY1M RY125CY1M RY140CY1M RY160CY1MDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m

standard heat pump

4 steps

8.792 8.792 11.137 11.723 14.654 16.410

8.792 8.792 11.280 11.723 15.533 16.410

2.86 / 2.89 2.81 / 2.84 2.98 / 3.28 3.17 / 3.65 2.90 / 3.49 2.73 / 3.30

1,535 1,563 1,868 1,849 2,524 3,005

C / D C / D C / C B / A C / B D / C

285x1,007x600 378x929x541 305x1,302x638 378x1,045x541 378x1,299x541 378x1,499x54138 39 41 42 54 62

-24.06 / 22.92 / 21.78 / 20.10 25.50 / 23.52 / 21.54 / 20.10 43.62 / 41.64 / 40.20 / 38.22 31.14 / 30.00 / 28.02 / 25.50 45.00 / 39.06 / 36.24 / 34.26 46.74 / 43.32 / 40.50 / 36.54

-67 / 64 / 61 / 57 76 / 73 / 69 / 64 80 / 76 / 73 / 70 78 / 76 / 72 / 68 78 / 76 / 73 / 70 79 / 78 / 75 / 71

-44 / 41 / 38 / 34 49 / 46 / 42 / 38 55 / 51 / 48 / 45 51 / 49 / 45 / 41 53 / 52 / 50 / 47 55 / 53 / 50 / 47

R-221~/220-240V/50Hz

850x1,030x40095 100 105 108

19.0~46.0-9.0~18.0

58 61R-22

3~/380-415V/50Hz9.52 / 15.9 9.52 / 19.1 12.7 / 19.1

45 35

FDYM-C / RY-CY

79

FDYM-CSLM3 RY-CY1M

Page 82: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Rooftop

! ‘Plug and Play’ installation: the single unit confi guration requires no additional piping work as both the indoor and outdoor sides are pre-connected.

! Refrigerant is factory pre-charged to ensure clean and effi cient operation.

! The air volume and static pressure required can be adjusted according to the requirement because of the use of a belt driven fan.

! The fl at top design of the unit allows for maximum utilization of warehouse and container space.

! High effi ciency and reliable scroll compressor.! Convertible: fan can be mounted in two directions

(Class 240-280-320-450-560).! Coil with anti-corrosion treatment.

HEAT PUMP NON-INVERTEROutdoor UnitsOutdoor Units UATYP180AMY1 UATYP240AMY1 UATYP280AMY1 UATYP320AMY1 UATYP450AMY1 UATYP560AMY1 UATYP700AMY1 UATYP850AMY1 UATYPC10AMY1 UATYPC12AMY1Capacity Cooling Minimum kW 16.705 21.101 25.790 29.307 43.668 55.684 67.406 82.939 101.110 109.609

Heating Nominal kW 20.222 22.566 29.89 35.755 46.891 67.406 74.733 92.317 102.290 126.314EER Cooling 2.44 2.51 2.38 2.28 2.64 2.63 2.31 2.17 2.34 2.27COP Heating 3.06 2.99 3.05 3.11 2.98 3.32 2.85 2.65 2.45 2.70Air Flow Rate evaporator Cooling m³/min 51 80 100 102 160 190 226 263 312 354External Static Pressure Pa 98 196 294Condensation Drain Size Diameter (OD) mm 25.4

Casing Colour Light GreyMaterial Electro galvanised mild steel

Dimensions Unit HxWxD mm 1000x1100x1530 1200x1990x1800 1735x2250x2800 1974x2252x3180Weight Unit kg 320 385 415 440 700 800 12000 1350 1510 1600Air Flow Rate condensor Cooling m³/min 127 160 283 320 566Operation Range Cooling Min-Max °CDB 20°C – 46°C

Heating Min-Max °CWD -15°C – 20°CSound Level Sound Power dBA 63 65 66 68 70 70 74 74 80 80Refrigerant Type R-407CPower Supply 3~/50Hz/380-415V

80

UATYP-A

UATYP-A

Page 83: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Rooftop

! ‘Plug and Play’ installation: the single unit confi guration requires no additional piping work as both the indoor and outdoor sides are pre-connected.

! Refrigerant is factory pre-charged to ensure clean and effi cient operation.

! The air volume and static pressure required can be adjusted according to the requirement because of the use of a belt driven fan.

! The fl at top design of the unit allows for maximum utilization of warehouse and container space.

! High effi ciency and reliable scroll compressor (UATY180, 320, 700, 850, C10, C12AMY1).

! Fan can be mounted for horizontal or vertical airfl ow inlet and discharge (class 320)

HEAT PUMP NON-INVERTEROutdoor UnitsOutdoor Units UATY180AMY1 UATY240AMY1 UATY280AMY1 UATY320AMY1 UATY450AMY1 UATY560AMY1 UATY700AMY1 UATY850AMY1 UATYC10AMY1 UATYC12AMY1Capacity Cooling Minimum kW 16.705 23.446 29.307 30.772 43.961 58.614 68.872 84.991 98.180 112.539

Heating Nominal kW 20.222 23.035 30.772 34.582 45.426 60.959 73.854 86.456 101.990 120.745EER Cooling 2.65 2.49 2.47 2.65 2.36 2.49 2.49 2.29 2.50 2.43COP Heating 3.18 2.95 3.06 3.09 2.95 2.99 2.80 2.56 2.85 2.96Air Flow Rate evaporator Cooling m³/min 51 80 100 102 160 190 226 263 312 354External Static Pressure Pa 98 196 294Condensation Drain Size Diameter (OD) mm 25.4

Casing Colour Light GreyMaterial Electro galvanised mild steel

Dimensions Unit HxWxD mm 1,000x1,100x1,530 1,000x1,300x1,530 1,200x1,990x1,800 1,735x2,250x2,800 1,974x2252x3,180Weight Unit kg 320 385 415 440 700 800 1,200 1,350 1,510 1,600Air Flow Rate condensor Cooling m³/min 127 160 283 320 566Operation Range Cooling Min-Max °CDB 20°C – 54°C

Heating Min-Max °CWD -15°C – 20°CSound Level Sound Power dBA 63 65 66 68 70 70 74 74 80 80Refrigerant Type R-22Power Supply 3~/50Hz/380-415V

81

UATY-A

UATY-A

Page 84: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

82

Twin / Triple / Double Twin Applications & Multi Model Applications

1. Twin, Triple, Double Twin RZQ-CV1 84 RZQ-BW1 86 RZQ-CY1 88RZQS-C 91 RQ-B 94 RYP-B 96

2. Multi model application RMXS-E 98 MXS-E/G/F 102

Page 85: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

83

It is possible to connect 2,3 or 4 indoor units to a single outdoor unit. The indoor units may be of different types (e.g. 4-way blow ceiling mounted cassette, wall mounted, ...) and even different capacities (e.g. 35 and 71 class).All indoor units are operated together within the same mode (cooling or heating) from one remote control. This allows equal air distribution, even in larger, irregularly shaped rooms.

The total capacities (outdoor base) for simultaneous operation are the same as for the pair applications.

Connectable indoor units:

Inverter controlled:• RZQ-B/C: FCQH-C*, FCQ-C*, FHQ-B, FUQ-B, FAQ-B, FDQ-B

• RZQS-C: FCQH-C, FCQ-C, FFQ-B, FBQ-B, FHQ-B, FAQ-B, FDQ-B

Non-inverter controlled:• RQ-B: FFQ-B, FBQ-B, FCQ-C, FHQ-B, FUQ-B, FAQ-B

• RYP-B: FHYBP-B, FDYP-B

POSSIBLE COMBINATIONS

TWINTWIN TRIPLETRIPLE DOUBLE TWINDOUBLE TWIN

RZQ71RZQS71RQ71

35+35(KHRQ22M20TA)

RZQ100RZQS100

50+50(KHRQ22M20TA)

35+35+35(KHRQ127H)

RQ10050+50

(KHRQ22M20TA)50+60

(KHRQ22M20TA)35+71

(KHRQ22M20TA)35+35+35

(KHRQ127H)RZQ125RZQS125

60+60(KHRQ22M20TA)

50+50+50(KHRQ127H)

35+35+35+35(3 x KHRQ22M20TA)

RQ12560+60

(KHRQ22M20TA)50+71

(KHRQ22M20TA)50+50+50

(KHRQ127H)RZQ140RZQS140

71+71(KHRQ22M20TA)

50+50+50(KHRQ127H)

35+35+35+35(3 x KHRQ22M20TA)

RZQ200100+100

(KHRQ22M20TA)60+60+60

(KHRQ250H7)71+71+71

(KHRQ250H7)50+50+50+50

(3 x KHRQ22M20TA)

RZQ250125+125

(KHRQ22M20TA)60+60+60+60

(3 x KHRQ22M20TA)

RYP200100+100

(KHRQ22M64T)71-125

(KHRQ22M64T)

71+71+71(KHRQ127H)

60+60+60(KHRQ127H)

45+71+71(KHRQ127H)

45+45+100(KHRQ127H) 45+45+45+45

(2 x KHRQ22M20TA + KHRQ22M64T)35+71+100

(KHRQ127H)35+35+125(KHRQ127H)

45+60+100(KHRQ127H)

60+60+71(KHRQ127H)

RYP250125+125

(KHRQ22M64T)45+100+100(KHRQ127H)

60+60+125(KHRQ127H)

45+71+125(KHRQ127H)

71+71+100(KHRQ127H)

60+60+60+60(2 x KHRQ22M20TA +

KHRQ22M64T)

* Note: For RZQ100,125,140B8W1B in combination with FCQ35~71C or FCQH71C, use the refrigerant branch piping KHRQ58T for twin, KHRQ58H for triple and KHRQ58T for double twin application.

Page 86: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FCQH71C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 FBQ71B8V3BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

204x840x84019 21

10.5 / 8.5 12.5 / 8.5 13.5 / 8.5 15.5 / 9.012.5 / 10.0 12.5 / 8.5 13.5 / 8.5 16.0 / 9.5

49 5131 / 27 33 / 2831 / 27 33 / 28 34 / 28

R-410A1~/220-240V/50/60Hz

246x840x84023

20.0 / 12.020.0 / 12.0

5234 / 2834 / 28R-410A

1~/220-240V/50/60Hz

286x575x57517.5

10.0 / 6.5 12.0 / 8.0 15.0 / 10.010.0 / 6.5 12.0 / 8.0 15.0 / 10.0

49.0 53.0 58.032.0 / 25.0 36.0 / 27.0 41.0 / 32.032.0 / 25.0 36.0 / 27.0 41.0 / 32.0

R-410A1~/230V/50Hz

300x700x800 300x1000x80030 31 41

11.5 / 9 14 / 10 19 / 14 19.00 / 14.0011.5 / 9 14 / 10 19 / 14 19.00 / 14.00

52 53 6052 53 60 -

33 / 29 34 / 30 34.0 / 30.033 / 29 34 / 30 34.0 / 30.0

R-410A1~/230V/50Hz

FCQ,FCQH,FFQ,FBQ,FHQ,FUQ,FAQ + RZQ-CV1

84

Page 87: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FUQ71BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FAQ71BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMP INVERTEROutdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

195x960x680 195x1160x68024.0 25.0 27.0

13.0 / 10.0 17.0 / 13.0 17.0 / 14.013.0 / 10.0 16.0 / 13.0 17.0 / 14.0

53.0 / 48.0 54.0 / 49.0 55.0 / 49.0 55.0 / 51.053.0 / 48.0 54.0 / 49.0 55.0 / 49.0 55.0 / 51.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.0

R-410A1~/220-240V/50Hz

165x895x89525.0

19.0 / 14.019.0 / 14.056.0 / 51.056.0 / 51.040.0 / 35.040.0 / 35.0

R-410A1~/220-240V/50Hz

290x1050x23013.0

19.0 / 15.019.0 / 15.059.0 / 53.059.0 / 53.043.0 / 37.043.0 / 37.0

R-410A1~/220-240V/50Hz

770x900x320 1170x900x32067 103

-15.0~50.0-20.0~15.5

63 65 66 6747 49 5049 51 5243 45 46

R-410A1~/220-240V/50Hz

9.52 / 15.9 / 2650 75

0.5

85

Page 88: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FCQH71C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 FBQ71B8V3BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

204x840x84019 21

10.5 / 8.5 12.5 / 8.5 13.5 / 8.5 15.5 / 9.012.5 / 10.0 12.5 / 8.5 13.5 / 8.5 16.0 / 9.5

49 5131 / 27 33 / 2831 / 27 33 / 28 34 / 28

R-410A1~/220-240V/50/60Hz

246x840x84023

20.0 / 12.020.0 / 12.0

5234 / 2834 / 28R-410A

1~/220-240V/50/60Hz

286x575x57517.5

10.0 / 6.5 12.0 / 8.0 15.0 / 10.010.0 / 6.5 12.0 / 8.0 15.0 / 10.0

49.0 53.0 58.032.0 / 25.0 36.0 / 27.0 41.0 / 32.032.0 / 25.0 36.0 / 27.0 41.0 / 32.0

R-410A1~/230V/50Hz

300x700x800 300x1000x80030 31 41

11.5 / 9 14 / 10 19 / 14 19.00 / 14.0011.5 / 9 14 / 10 19 / 14 19.00 / 14.00

52 53 6052 53 60 -

33 / 29 34 / 30 34.0 / 30.033 / 29 34 / 30 34.0 / 30.0

R-410A1~/230V/50Hz

FCQ,FCQH,FFQ,FBQ,FHQ,FUQ,FAQ + RZQ-BW1

86

Page 89: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FAQ71BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMP INVERTEROutdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

195x960x680 195x1160x68024.0 25.0 27.0

13.0 / 10.0 17.0 / 13.0 17.0 / 14.013.0 / 10.0 16.0 / 13.0 17.0 / 14.0

53.0 / 48.0 54.0 / 49.0 55.0 / 49.0 55.0 / 51.053.0 / 48.0 54.0 / 49.0 55.0 / 49.0 55.0 / 51.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.0

R-410A1~/220-240V/50Hz

165x895x895 230x895x89525.0 31.0

19.0 / 14.0 29.0 / 21.0 32.0 / 23.019.0 / 14.0 29.0 / 21.0 32.0 / 23.056.0 / 51.0 59.0 / 54.0 60.0 / 55.056.0 / 51.0 59.0 / 54.0 60.0 / 55.040.0 / 35.0 43.0 / 38.0 44.0 / 39.040.0 / 35.0 43.0 / 38.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

290x1050x23013.0

19.0 / 15.019.0 / 15.059.0 / 53.059.0 / 53.043.0 / 37.043.0 / 37.0

R-410A1~/220-240V/50Hz

1345x900x320106

-15.0~50.0-20.0~15.5

65.0 66.049.0 50.051.0 52.0

45.0R-410A

3N~/400V/50Hz9.52 / 15.9 / 26

750.5

87

Page 90: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB FCQ100C7VEB FCQ125C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FFQ50B8V1B FFQ60B8V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

204x840x840 246x840x84021 23

12.5 / 8.5 13.5 / 8.5 15.5 / 9.0 23.5 / 16.0 27.5 / 19.012.5 / 8.5 13.5 / 8.5 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0

51 54 5833 / 28 37 / 32 41 / 3533 / 28 34 / 28 37 / 32 41 / 35

R-410A1~/220-240V/50/60Hz

246x840x840 288x840x84023 25

20.0 / 12.0 32.5 / 18.0 32.5 / 21.520.0 / 12.0 32.5 / 18.0 32.5 / 21.5

52 6034 / 28 43 / 32 43 / 3634 / 28 43 / 32 43 / 36

R-410A1~/220-240V/50/60Hz

286x575x57517.5

12.0 / 8.0 15.0 / 10.012.0 / 8.0 15.0 / 10.0

53.0 58.036.0 / 27.0 41.0 / 32.036.0 / 27.0 41.0 / 32.0

R-410A1~/230V/50Hz

FCQ,FCQH,FFQ,FBQ,FHQ,FUQ,FAQ,FDQ +

RZQ-CY1

88

Page 91: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FBQ50B8V1 FBQ60B8V1 FBQ71B8V3B FBQ100B8V3B FBQ125B8V3BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FHQ50BVV1B FHQ60BVV1B FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

300x700x800 300x1000x800 300x1400x80031 41 51.0 52.0

14 / 10 19 / 14 19.00 / 14.00 27.00 / 20.00 35.00 / 24.0014 / 10 19 / 14 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00

53 60 62.0 63.053 60 -

33 / 29 34 / 30 34.0 / 30.0 36.0 / 31.0 38.0 / 32.033 / 29 34 / 30 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0

R-410A1~/230V/50Hz

195x960x680 195x1160x680 195x1400x680 195x1590x68025.0 27.0 32.0 35.0

13.0 / 10.0 17.0 / 13.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.013.0 / 10.0 16.0 / 13.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.054.0 / 49.0 55.0 / 49.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.054.0 / 49.0 55.0 / 49.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.038.0 / 33.0 39.0 / 33.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.038.0 / 33.0 39.0 / 33.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

165x895x895 230x895x89525.0 31.0

19.0 / 14.0 29.0 / 21.0 32.0 / 23.019.0 / 14.0 29.0 / 21.0 32.0 / 23.056.0 / 51.0 59.0 / 54.0 60.0 / 55.056.0 / 51.0 59.0 / 54.0 60.0 / 55.040.0 / 35.0 43.0 / 38.0 44.0 / 39.040.0 / 35.0 43.0 / 38.0 44.0 / 39.0

R-410A1~/220-240V/50Hz

290x1050x230 360x1570x20013.0 26.0

19.0 / 15.0 23.0 / 19.019.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.043.0 / 37.0 45.0 / 41.0

R-410A1~/220-240V/50Hz

89

Page 92: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FDQ125B8V3BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min

Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA

Heating Low dBARefrigerant TypePower Supply

HEAT PUMP INVERTEROutdoor UnitOutdoor Unit RZQ200C7Y1B RZQ250C7Y1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound power dBASound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m

350x1400x66259.043.043.075.044.044.0

R-410A1~/230V/50Hz

1680x930x765183 184

-5.0~46.0-15.0~15.0

7857

R-410A3N~/380-415V/50Hz

9.5 / 22.2100

90

Page 93: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems
Page 94: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FCQH71C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

204x840x84019 21

10.5 / 8.5 12.5 / 8.5 13.5 / 8.5 15.5 / 9.012.5 / 10.0 12.5 / 8.5 13.5 / 8.5 16.0 / 9.5

49 5131 / 27 33 / 2831 / 27 33 / 28 34 / 28

R-410A1~/220-240V/50/60Hz

246x840x84023

20.0 / 12.020.0 / 12.0

5234 / 2834 / 28R-410A

1~/220-240V/50/60Hz

286x575x57517.5

10.0 / 6.5 12.0 / 8.0 15.0 / 10.010.0 / 6.5 12.0 / 8.0 15.0 / 10.0

49.0 53.0 58.032.0 / 25.0 36.0 / 27.0 41.0 / 32.032.0 / 25.0 36.0 / 27.0 41.0 / 32.0

R-410A1~/230V/50Hz

FCQ,FCQH,FFQ,FBQ,FHQ,FAQ + RZQS-C

92

Page 95: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FBQ35B8V1 FBQ50B8V1 FBQ60B8V1 FBQ71B8V3BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FAQ71BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMP INVERTEROutdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m

300x700x800 300x1000x80030 31 41

11.5 / 9 14 / 10 19 / 14 19.00 / 14.0011.5 / 9 14 / 10 19 / 14 19.00 / 14.00

52 53 6052 53 60 -

33 / 29 34 / 30 34.0 / 30.033 / 29 34 / 30 34.0 / 30.0

R-410A1~/230V/50Hz

195x960x680 195x1160x68024.0 25.0 27.0

13.0 / 10.0 17.0 / 13.0 17.0 / 14.013.0 / 10.0 16.0 / 13.0 17.0 / 14.0

53.0 / 48.0 54.0 / 49.0 55.0 / 49.0 55.0 / 51.053.0 / 48.0 54.0 / 49.0 55.0 / 49.0 55.0 / 51.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.0

R-410A1~/220-240V/50Hz

290x1050x23013.0

19.0 / 15.019.0 / 15.059.0 / 53.059.0 / 53.043.0 / 37.043.0 / 37.0

R-410A1~/220-240V/50Hz

770x900x320 700x900x320 1,170x900x320 1170x900x32068 103

-5~46-15~15.5

65 67 6849 51 5251 55 53 5447 49 50

R-410A220-240V/50Hz9.52 / 15.9 / 26

30 500.5

93

Page 96: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FAQ71BVV1BDimensions (Height x Width x Depth) mm 290x1050x230Weight kg 13.0Air Flow Rate Cooling High/Low m³/min 19.0 / 15.0

Heating High/Low m³/min 19.0 / 15.0Sound Power Cooling High/Low dBA 59.0 / 53.0Sound Pressure Cooling High/Low dBA 43.0 / 37.0

Heating High/Low dBA 43.0 / 37.0Refrigerant Type R-410APower Supply 1~/220-240V/50Hz

HEAT PUMPIndoor UnitsIndoor Units FBQ71B8V3B FBQ35B8V1 FBQ50B8V1 FBQ60B8V1Dimensions (Height x Width x Depth) mm 300x1000x800 300x700x800 300x1000x800Weight kg 41.0 30 31 41Air Flow Rate Cooling High/Low m³/min 19.00 / 14.00 11.5 / 9 14 / 10 19 / 14

Heating High/Low m³/min 19.00 / 14.00 11.5 / 9 14 / 10 19 / 14Sound Power Cooling High dBA 60.0 52 53 60Sound Pressure Cooling High/Low dBA 34.0 / 30.0 33 / 29 34 / 30

Heating High/Low dBA 34.0 / 30.0 33 / 29 34 / 30Refrigerant Type R-410APower Supply 1~/230V/50Hz

HEAT PUMPIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB Dimensions (Height x Width x Depth) mm 204x840x840 204x840x840 204x840x840 204x840x840Weight kg 19 19 19 21Air Flow Rate Cooling High/Low m3/min 10.0 / 8.5 12.5 / 8.5 13.5 / 8.5 15.5 / 9.0

Heating High/Low m3/min 12.5 / 10.0 12.5 / 8.5 13.5 / 8.5 16.5 / 9.5Sound Power level Cooling High dBA 49 49 51 51Sound Pressure Cooling High/Low dBA 31 / 27 32 / 27 33 / 28 33 / 28

Heating High/Low dBA 31 / 27 32 / 27 33 / 28 34 / 28Refrigerant Type R-410A R-410A R-410A R-410A

Power Supply 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz

94

FAQ,FBQ,FCQ,FFQ,FHQ,FUQ + RQ

Page 97: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FFQ35B8V1B FFQ50B8V1B FFQ60B8V1BDimensions (Height x Width x Depth) mm 286x575x575Weight kg 17.5Air Flow Rate Cooling High/Low m³/min 10.0 / 6.5 12.0 / 8.0 15.0 / 10.0

Heating High/Low m³/min 10.0 / 6.5 12.0 / 8.0 15.0 / 10.0Sound Power Cooling High dBA 49.0 53.0 58.0Sound Pressure Cooling High/Low dBA 32.0 / 25.0 36.0 / 27.0 41.0 / 32.0

Heating High/Low dBA 32.0 / 25.0 36.0 / 27.0 41.0 / 32.0Refrigerant Type R-410APower Supply 1~/230V/50Hz

HEAT PUMPIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1B FHQ71BVV1BDimensions (Height x Width x Depth) mm 195x960x680 195x1160x680Weight kg 24.0 25.0 27.0Air Flow Rate Cooling High/Low m³/min 13.0 / 10.0 17.0 / 13.0 17.0 / 14.0

Heating High/Low m³/min 13.0 / 10.0 16.0 / 13.0 17.0 / 14.0Sound Power Cooling High/Low dBA 53.0 / 48.0 54.0 / 49.0 55.0 / 49.0 55.0 / 51.0Sound Pressure Cooling High/Low dBA 37.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.0

Heating High/Low dBA 37.0 / 32.0 38.0 / 33.0 39.0 / 33.0 39.0 / 35.0Refrigerant Type R-410APower Supply 1~/220-240V/50Hz

HEAT PUMPIndoor UnitsIndoor Units FUQ71BVV1BDimensions (Height x Width x Depth) mm 165x895x895Weight kg 25Air Flow Rate Cooling High/Low m³/min 19/14

Heating High/Low m³/min 19/14Sound Power Cooling High/Low dBA 40/35Sound Pressure Cooling High/Low dBA 56/51

Heating High/Low dBA 56/51Refrigerant Type R-410APower Supply

HEAT PUMP NON-INVERTEROutdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mm 770x900x320 1170x900x320Weight kg 84 83 103 101 108Sound pressure level Cooling dBA 50 50 53 53 53Sound power level Cooling dBA 63 63 66 66 67Operation Range Cooling Min~Max °CDB -5.0~46.0

Heating Min~Max °CWB -10~15Refrigerant Type R-410APower Supply 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50HzPiping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26Piping Length (Maximum) m 70Max. internunit level difference m 0.5

95

1~/220-240V/50Hz

Page 98: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FDYP125B7V1Dimensions (Height x Width x Depth) mm 350x1400x662Weight kg 59.0Air Flow Rate Cooling Medium m³/min 43.00

Heating Medium m³/min 43.00Sound Power Cooling High dBA 75.0Sound Pressure Cooling High dBA 44.0

Heating High dBA 44.0Refrigerant Type R-407CPower Supply 1~/230V/50Hz

HEAT PUMPIndoor UnitsIndoor Units FHYBP71B7V1 FHYBP100B7V1 FHYBP125B7V1Dimensions (Height x Width x Depth) mm 300x1000x800 300x1400x800Weight kg 41.0 51.0 52.0Air Flow Rate Cooling High/Low m³/min 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00

Heating High/Low m³/min 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00Sound Power Cooling High dBA 60.0 62.0 63.0Sound Pressure Cooling High/Low dBA 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0

Heating High/Low dBA 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0Refrigerant Type R-407CPower Supply 1~/230V/50Hz

HEAT PUMPOutdoor UnitOutdoor Unit RYP200B7W1 RYP250B7W1Dimensions (Height x Width x Depth) mm 1220x1290x700 1440x1290x700Weight kg 196 210Sound pressure level Cooling dBA 57

Heating dBA 57Sound power level Cooling dBA 77Operation Range Cooling Min~Max °CDB -5~46

Heating Min~Max °CWB -10~15Refrigerant Type R-407CPower Supply 3~/400V/50HzPiping connections Liquid (OD)/Gas/Drain mm 12.7 / 28.6 / 26 15.9 / 28.6 / 26Piping Length (Maximum) m 50Max. internunit level difference m -

96

FDYP,FHYBP + RYP

Page 99: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems
Page 100: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Super Multi Plus

HEAT PUMPIndoor UnitsIndoor Units FTXG25EV1BW FTXG25EV1BS FTXG35EV1BW FTXG35EV1BSDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units CTXG50EV1BW CTXG50EV1BSDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

CONNECTABLE INDOOR UNITS20 class 25 class 35 class 42 class 50 class 60 class 71 class

Stylish wall mounted unit - FTXG25E FTXG35E - CTXG50E - -Wall mounted unit FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60F FTXS71FFloor standinig unit - FVXS25F FVXS35F - FVXS50F - -Flexi type unit - FLXS25B FLXS35B - FLXS50B FLXS60B -Slim concealed ceiling unit - FDXS25E FDXS35E - FDXS50C FDXS60C -Concealed ceiling unit - FDBQ25B FBQ35B - FBQ50B FBQ60B -4-way blow ceiling mounted cassette (600x600) - FFQ25B FFQ35B - FFQ50B FFQ60B -Round fl ow cassette - - FCQ35C - FCQ50C FCQ60C -4-way blow ceiling suspended cassette - - FHQ35B - FHQ50B FHQ60B -

275x840x1509.0

7.7 / 6.1 / 4.7 / 3.8 8.1 / 6.5 / 4.9 / 4.19.0 / 7.9 / 6.7 / 5.4 9.6 / 8.2 / 6.7 / 5.9

56.0 57.056.0 57.0

38.0 / 32.0 / 25.0 / 22.0 39.0 / 33.0 / 26.0 / 23.038.0 / 33.0 / 28.0 / 25.0 39.0 / 34.0 / 29.0 / 29.0

R-410A1~/220-240V/50Hz

275x840x1509.0

11.3 / 9.1 / 7.1 / 6.712.6 / 10.6 / 8.7 / 7.7

64.064.0

47.0 / 41.0 / 35.0 / 32.047.0 / 41.0 / 35.0 / 32.0

R-410A1~/220-240V/50Hz

295x800x2159 10

9.4 / 7.4 / 5.5 / 4.0 9.1 / 7.1 / 5.2 / 3.7 10.4 / 7.7 / 4.8 / 3.5 9.1 / 7.7 / 6.3 / 5.4 10.2 / 8.6 / 7.0 / 6.09.9 / 8.2 / 6.5 / 5.5 9.8 / 7.9 / 6.2 / 5.2 10.6 / 8.5 / 6.4 / 5.4 11.2 / 9.4 / 7.7 / 6.8 11.0 / 9.3 / 7.6 / 6.7

54 58 5954 55 58 60

38 / 32 / 25 / 22 42 / 34 / 26 / 23 42 / 38 / 33 / 30 43 / 39 / 34 / 3138 / 33 / 28 / 25 39 / 34 / 28 / 25 42 / 36 / 29 / 26 42 / 38 / 33 / 30 44 / 39 / 34 / 31

R-410A1~/220-230-240V/50Hz

RMXS-E

98

Page 101: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FTXS60FV1B FTXS71FV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling Medium dBA

Heating Medium dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FLXS25BAVMB FLXS35BAVMB FLXS50BAVMB FLXS60BAVMBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FDXS25EAVMB FDXS35EAVMBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

290x1050x23812

16.2 / 13.6 / 11.4 / 10.2 17.4 / 14.6 / 11.6 / 10.617.4 / 15.1 / 12.7 / 11.4 19.7 / 16.9 / 14.3 / 12.7

61 6260 62

45 / 41 / 36 / 33 46 / 42 / 37 / 3444 / 40 / 35 / 32 46 / 42 / 37 / 34

R-410A1~/220-240V/50Hz

490x1050x20016.0 17.0

7.60 / 6.80 / 6.00 / 5.2 8.60 / 7.60 / 6.60 / 5.6 11.40 / 10.00 / 8.50 / 7.6 12.00 / 10.70 / 9.30 / 8.39.20 / 8.30 / 7.40 / 6.6 9.80 / 8.90 / 8.00 / 7.2 12.1 / 9.8 / 7.5 / 6.8 12.80 / 10.60 / 8.40 / 7.5

53.0 54.0 63.0 64.0- 62.0 63.0

37.0 / 34.0 / 31.0 / 28.0 38.0 / 35.0 / 32.0 / 29.0 47.0 / 43.0 / 39.0 / 36.0 48.0 / 45.0 / 41.0 / 39.037.0 / 34.0 / 31.0 / 29.0 39.0 / 36.0 / 33.0 / 30.0 46.0 / 41.0 / 35.0 / 33.0 47.0 / 42.0 / 37.0 / 34.0

R-410A1~/220-240/220-230V/50/60Hz

600x700x21014

8.2 / 6.5 / 4.8 / 4.1 8.5 / 6.7 / 4.9 / 4.5 10.7 / 9.2 / 7.8 / 6.68.8 / 6.9 / 5.0 / 4.4 9.4 / 7.3 / 5.2 / 4.7 11.8 / 10.1 / 8.5 / 7.1

54 55 5654 55 57

38 / 32 / 26 / 23 39 / 33 / 27 / 24 44 / 40 / 36 / 3238 / 32 / 26 / 23 39 / 33 / 27 / 24 45 / 40 / 36 / 32

R-410A1~/220-240V/50Hz

200x700x62021.0

8.7 / 8.0 / 7.3 / 6.28.7 / 8.0 / 7.3 / 6.2

53.053.0

35.0 / 33.0 / 31.0 / 29.035.0 / 33.0 / 31.0 / 29.0

R-410A1~/220-240/220-230V/50/60Hz

99

Page 102: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FDXS50CVMB FDXS60CVMBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FDBQ25B8V1Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FBQ35B8V1 FBQ50B8V1 FBQ60B8V1Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B FFQ60B8V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

200x900x620 200x1100x62027.0 30.0

12.0 / 11.0 / 10.0 / 8.4 16.0 / 14.8 / 13.5 / 11.212.0 / 11.0 / 10.0 / 8.4 16.0 / 14.8 / 13.5 / 11.2

55.0 56.055.0 56.0

37.0 / 35.0 / 33.0 / 31.0 38.0 / 36.0 / 34.0 / 32.037.0 / 35.0 / 33.0 / 31.0 38.0 / 36.0 / 34.0 / 32.0

R-410A1~/220-240/220-230V/50/60Hz

230x652x50217.0

6.50 / 5.206.95 / 5.2055.0 / 49.055.0 / 49.035.0 / 28.035.0 / 29.0

R-410A1~/230V/50Hz

300x700x800 300x1000x80030 31 41

11.5 / 9 14 / 10 19 / 1411.5 / 9 14 / 10 19 / 14

52 53 6052 53 60

33 / 29 34 / 3033 / 29 34 / 30

R-410A1~/230V/50Hz

286x575x57517.5

9.0 / 6.5 10.0 / 6.5 12.0 / 8.0 15.0 / 10.09.0 / 6.5 10.0 / 6.5 12.0 / 8.0 15.0 / 10.0

46.5 49.0 53.0 58.029.5 / 24.5 32.0 / 25.0 36.0 / 27.0 41.0 / 32.029.5 / 24.5 32.0 / 25.0 36.0 / 27.0 41.0 / 32.0

R-410A1~/230V/50Hz

100

Page 103: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMP INVERTEROutdoor UnitOutdoor Unit RMXS112E8V1B RMXS140E8V1B RMXS160E8V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure Cooling dBA

Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmMax. internunit level difference m

BRANCH PROVIDERBRANCH PROVIDER BPMKS967B2 BPMKS967B3Connectable indoor unitsMax. indoor unit connectable capacityMax. connectable combinationDimensions (HeightxWidthxDepth) mmWeight kg

204x840x84019

10.5 / 8.5 12.5 / 8.5 13.5 / 8.512.5 / 10.0 12.5 / 8.5 13.5 / 8.5

49 5131 / 27 33 / 2831 / 27 33 / 28

R-410A1~/220-240V/50/60Hz

195x960x680 195x1160x68024.0 25.0 27.0

13.0 / 10.0 17.0 / 13.013.0 / 10.0 16.0 / 13.0

53.0 / 48.0 54.0 / 49.0 55.0 / 49.053.0 / 48.0 54.0 / 49.0 55.0 / 49.037.0 / 32.0 38.0 / 33.0 39.0 / 33.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0

R-410A1~/220-240V/50Hz

1345x900x320125

-5~46-15~20

67 68 7051 52 5453 54 55

47/44/41 47/44/41R-410A

1~/230V/50Hz9.52 / 19.1 / 26x3

15

1~2 1~314.2 20.8

71+71 60+71+71180x294x350

7 8

101

Page 104: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FTXG25EV1BW FTXG25EV1BS FTXG35EV1BW FTXG35EV1BSDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units CTXG50EV1BW CTXG50EV1BSDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

Multi Model ApplicationInverter Controlled

CONNECTABLE INDOOR UNITS2MXS40G 2MXS50G 3MXS52E 3MXS68G 3MXS68G 3MXS68G 4MXS68G

Stylish wall mounted unit FTXG25,35E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50EWall mounted unit FTXS20,25,35G FTXS20,25,35,42,50G FTXS20,25,35,42,50G FTXS20,25,35,42,50G FTXS20,25,35,42,50G FTXS20,25,35,42,50G FTXS20,25,35,42,50G

- - - FTXS60F FTXS60F FTXS60,71F FTXS60,71FSlim concealed ceiling unit FDXS25,35E FDXS25,35E FDXS25,35E FDXS25,35E FDXS25,35E FDXS25,35E FDXS25,35E

- FDXS50C FDXS50C FDXS50C FDXS50C FDXS50C FDXS50CFloor standing unit FVXS25,35F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50F FVXS25,35,50FFlexi type unit FLXS25,35B FLXS25,35,50B FLXS25,35,50B FLXS25,35,50B FLXS25,35,50B FLXS25,35,50B FLXS25,35,50BRound fl ow cassette - - FCQ35,50C FCQ35,50C FCQ35,50C FCQ35,50C FCQ35,50C4-way blow ceiling mounted cassette (600x600) - FFQ25,35,50B FFQ25,35,50B FFQ25,35,50,60B FFQ25,35,50,60B FFQ25,35,50,60B FFQ25,35,50,60BConcealed ceiling unit - - FDBQ25B FDBQ25B FDBQ25B FDBQ25B FDBQ25B

- - FBQ35,50B FBQ35,50,60B FBQ35,50,60B FBQ35,50,60B FBQ35,50,60B4-way blow ceiling suspended cassette - - FHQ35,50B FHQ35,50,60B FHQ35,50,60B FHQ35,50,60B FHQ35,50,60B

275x840x1509.0

7.7 / 6.1 / 4.7 / 3.8 8.1 / 6.5 / 4.9 / 4.19.0 / 7.9 / 6.7 / 5.4 9.6 / 8.2 / 6.7 / 5.9

56.0 57.056.0 57.0

38.0 / 32.0 / 25.0 / 22.0 39.0 / 33.0 / 26.0 / 23.038.0 / 33.0 / 28.0 / 25.0 39.0 / 34.0 / 29.0 / 29.0

R-410A1~/220-240V/50Hz

275x840x1509.0

11.3 / 9.1 / 7.1 / 6.712.6 / 10.6 / 8.7 / 7.7

64.064.0

47.0 / 41.0 / 35.0 / 32.047.0 / 41.0 / 35.0 / 32.0

R-410A1~/220-240V/50Hz

295x800x2159 10

9.4 / 7.4 / 5.5 / 4.0 9.1 / 7.1 / 5.2 / 3.7 10.4 / 7.7 / 4.8 / 3.5 9.1 / 7.7 / 6.3 / 5.4 10.2 / 8.6 / 7.0 / 6.09.9 / 8.2 / 6.5 / 5.5 9.8 / 7.9 / 6.2 / 5.2 10.6 / 8.5 / 6.4 / 5.4 11.2 / 9.4 / 7.7 / 6.8 11.0 / 9.3 / 7.6 / 6.7

54 58 5954 55 58 60

38 / 32 / 25 / 22 42 / 34 / 26 / 23 42 / 38 / 33 / 30 43 / 39 / 34 / 3138 / 33 / 28 / 25 39 / 34 / 28 / 25 42 / 36 / 29 / 26 42 / 38 / 33 / 30 44 / 39 / 34 / 31

R-410A1~/220-230-240V/50Hz

MXS-E/G/F

102

Page 105: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FTXS60FV1B FTXS71FV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling Medium dBA

Heating Medium dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FTXS60FV1B FTXS71FV1B FLXS60BAVMBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FDXS25EAVMB FDXS35EAVMBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

290x1050x23812

16.2 / 13.6 / 11.4 / 10.2 17.4 / 14.6 / 11.6 / 10.617.4 / 15.1 / 12.7 / 11.4 19.7 / 16.9 / 14.3 / 12.7

61 6260 62

45 / 41 / 36 / 33 46 / 42 / 37 / 3444 / 40 / 35 / 32 46 / 42 / 37 / 34

R-410A1~/220-240V/50Hz

490x1050x20016.0 17.0

8.60 / 7.60 / 6.60 / 5.6 11.40 / 10.00 / 8.50 / 7.6 12.00 / 10.70 / 9.30 / 8.39.80 / 8.90 / 8.00 / 7.2 12.1 / 9.8 / 7.5 / 6.8 12.80 / 10.60 / 8.40 / 7.5

54.0 63.0 64.0- 62.0 63.0

38.0 / 35.0 / 32.0 / 29.0 47.0 / 43.0 / 39.0 / 36.0 48.0 / 45.0 / 41.0 / 39.039.0 / 36.0 / 33.0 / 30.0 46.0 / 41.0 / 35.0 / 33.0 47.0 / 42.0 / 37.0 / 34.0

R-410A1~/220-240/220-230V/50/60Hz

600x700x21014

8.2 / 6.5 / 4.8 / 4.1 8.5 / 6.7 / 4.9 / 4.5 10.7 / 9.2 / 7.8 / 6.68.8 / 6.9 / 5.0 / 4.4 9.4 / 7.3 / 5.2 / 4.7 11.8 / 10.1 / 8.5 / 7.1

54 55 5654 55 57

38 / 32 / 26 / 23 39 / 33 / 27 / 24 44 / 40 / 36 / 3238 / 32 / 26 / 23 39 / 33 / 27 / 24 45 / 40 / 36 / 32

R-410A1~/220-240V/50Hz

200x700x62021.0

8.7 / 8.0 / 7.3 / 6.28.7 / 8.0 / 7.3 / 6.2

53.053.0

35.0 / 33.0 / 31.0 / 29.035.0 / 33.0 / 31.0 / 29.0

R-410A1~/220-240/220-230V/50/60Hz

103

Page 106: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FDXS50CVMB FDXS60CVMBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min

Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA

Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FDBQ25B8V1Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FBQ35B8V1 FBQ50B8V1 FBQ60B8V1Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBA

Heating High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B FFQ60B8V1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

200x900x620 200x1100x62027.0 30.0

12.0 / 11.0 / 10.0 / 8.4 16.0 / 14.8 / 13.5 / 11.212.0 / 11.0 / 10.0 / 8.4 16.0 / 14.8 / 13.5 / 11.2

55.0 56.055.0 56.0

37.0 / 35.0 / 33.0 / 31.0 38.0 / 36.0 / 34.0 / 32.037.0 / 35.0 / 33.0 / 31.0 38.0 / 36.0 / 34.0 / 32.0

R-410A1~/220-240/220-230V/50/60Hz

230x652x50217.0

6.50 / 5.206.95 / 5.2055.0 / 49.055.0 / 49.035.0 / 28.035.0 / 29.0

R-410A1~/230V/50Hz

300x700x800 300x1000x80030 31 41

11.5 / 9 14 / 10 19 / 1411.5 / 9 14 / 10 19 / 14

52 53 6052 53 60

33 / 29 34 / 3033 / 29 34 / 30

R-410A1~/230V/50Hz

286x575x57517.5

9.0 / 6.5 10.0 / 6.5 12.0 / 8.0 15.0 / 10.09.0 / 6.5 10.0 / 6.5 12.0 / 8.0 15.0 / 10.0

46.5 49.0 53.0 58.029.5 / 24.5 32.0 / 25.0 36.0 / 27.0 41.0 / 32.029.5 / 24.5 32.0 / 25.0 36.0 / 27.0 41.0 / 32.0

R-410A1~/230V/50Hz

104

Page 107: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

HEAT PUMPIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB FCQ60C7VEBDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMPIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1B FHQ60BVV1BDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min

Heating High/Low m³/minSound Power Cooling High/Low dBA

Heating High/Low dBASound Pressure Cooling High/Low dBA

Heating High/Low dBARefrigerant TypePower Supply

HEAT PUMP INVERTEROutdoor UnitOutdoor Unit 2MXS40G2V1B 2MXS50G2V1B 3MXS68G2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB

Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA

Heating dBASound Pressure (High) Cooling dBA

Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Drain mmPiping Length (Maximum) m 30 (for total of each room) 20 (for 1 room) 60 (for total of each room) 25 (for 1 room)Max. internunit level difference m

HEAT PUMP INVERTEROutdoor UnitOutdoor Unit 3MX552E2V1B 4MXS68F2V1B 4MXS80E7V3B 5MXS90E7V3BDimension HxWxD mmWeight kgOperation range Cooling Min~Max °CDB

Heating Min~Max °CDBSound Power Cooling dB(A)Sound Pressure (low) Cooling dB(A)

Heating dB(A)Sound Pressure (high) Cooling dB(A)

Heating dB(A)Refrigerant TypePiping Connection Liquid (OD)/Gas/Drain mmPiping Lenght (Maximum) mMax. internunit leve difference m

204x840x84019

10.5 / 8.5 12.5 / 8.5 13.5 / 8.512.5 / 10.0 12.5 / 8.5 13.5 / 8.5

49 5131 / 27 33 / 2831 / 27 33 / 28

R-410A1~/220-240V/50/60Hz

195x960x680 195x1160x68024.0 25.0 27.0

13.0 / 10.0 17.0 / 13.013.0 / 10.0 16.0 / 13.0

53.0 / 48.0 54.0 / 49.0 55.0 / 49.053.0 / 48.0 54.0 / 49.0 55.0 / 49.037.0 / 32.0 38.0 / 33.0 39.0 / 33.037.0 / 32.0 38.0 / 33.0 39.0 / 33.0

R-410A1~/220-240V/50Hz

550x765x285 735x936x30038 42 58

10~46 -10~46-15~15.5

62 63 6143 44 -44 46 -47 4848 50 49

R-410A1~/220-240V/50Hz 1~/230V/50Hz

6.35 / 18 -- 6.35 / 12.7 / 18

7.5

735x936x300 735x936x300 770x900x320 770x900x32049 58 72 73

-10~46 -10~46 -10~46 -10~46-15~15.5 -15~15.5 -15~15.5 -15~15.5

59 61 62 66- - - -- - - -

46 48 48 5247 49 49 52

R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz

50 60 70 757.5 7.5 7.5 7.5

105

Page 108: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

POWER Supply

T1 = 3~, 220V, 50HZV1 = 1~, 220-240V, 50HZVE = 1~, 220-240V, 50HZ/60HZV3 = 1~, 230V, 50HZVM = 1~, 220~240V/220~230V, 50HZ/60HZW1 = 3N~, 400V, 50HZY1 = 3~, 400V, 50HZ

MEASURING Conditions

COOLING ONLY

1) nominal cooling capacities are based on:indoor temperature 27°CDB/19°CWBoutdoor temperature 35°CDBrefrigerant piping length 7.5m - 8/5m VRV®

level difference 0m

HEAT PUMP

1) nominal cooling capacities are based on:indoor temperature 27°CDB/19°CWBoutdoor temperature 35°CDBrefrigerant piping length 7.5m - 8/5m VRV®

level difference 0m2) nominal heating capacities are based on:indoor temperature 20°CDBoutdoor temperature 7°CDB/6°CWBrefrigerant piping length 7.5m - 8/5m VRV®

level difference 0m

CHILLERS:

Air-cooled cooling only evaporator: 12°C/7°C ambient: 35°CDBheat pump evaporator: 12°C/7°C ambient: 35°C

condenser: 40°C/45°C ambient: 7°CDB/6°CWBWater-cooled cooling only evaporator: 12°C/7°C

condenser: 30°C/35°Cheating only evaporator: 12°C/7°C

condenser: 40°C/45°CRemote condenser evaporator: 12°C/7°C

condensing temperature: 45°C / liquid temperature: 40°CRemote evaporator cooling capacity/power input conditions suction dew point: 5°C ambient: 35°C

superheat: 10°CFan coil units cooling room temperature: 27°C/19°C

entering water temperature: 7°C/12°Cheating room temperature: 20°C

water inlet temperature: 50°C (2-pipe)/70°C (4-pipe)

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the “power” which a sound source generates.For more detailed information please consult our technical databooks.

106

Page 109: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Fan onlyThe air conditioner can be used as fan, blowing air without cooling or heating.

Dry programmeAllows humidity levels to be reduced without variations in room temperature.

Auto cooling-heating changeover Automatically selects cooling or heating mode to achieve the set temperature(heat pump types only).

Auto-restartThe unit restarts automatically at the original settings after power failure.

Draught preventionWhen starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.

Horizontal auto swingPossibility to select automatic horizontal moving of the air discharge louvre, for uniform air fl ow and temperature distribution.

Vertical auto swingPossibility to select automatic vertical moving of the air discharge louvre, for uniform air fl ow and temperature distribution.

Wired remote controlWired remote control to start, stop and regulate the air conditioner from a distance.

Infrared remote controlInfrared remote control with LCD to start, stop and regulate the air conditioner from a distance.

Econo modeThis function decreases the power consumption so that other applicances that need large power consumption can be used. This function is also energy saving.

Single screw compressorCompact, high effi cient, silent reliable Daikin compressor.Maintenance free (inspection only after 40,000 hours of operation)

Scroll compressorSilent, reliable Daikin compressor used in medium sized outdoor units.

Self-diagnosisSimplifi es maintenance by indicating system faults or operating anomalies.

Ceiling soiling preventionA special function prevents air blowing out too long in horizontal position, to prevent ceiling stains.

Night set modeSaves energy, by preventing overcooling or overheating during night time.

24 Hour timerTimer can be set to start cooling/heating anytime during a 24-hour period.

Auto fan speedAutomatically selects the necessary fan speed to reach or maintain the set temperature.

Energy effi ciencyDaikin air conditioners are energy effi cient and economical.

Movement sensorThe sensor detects whether someone is in the room. When the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room.

Home leave operationDuring absence, the indoor temperature can be maintained at a certain level.

‘We Care’ Icons

A number of ‘We Care’ icons are highlighted in green throughout the catalogue to indicate product features that have an impact on reducing energy consumption:

107

Page 110: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

3-D Air fl owThis function combines Vertical and Horizontal auto-swing to circulate a stream of cool/warm air right to the corners of even large spaces.

Comfort modeThe new fl ap changes the discharge angle horizontally for cooling operation and downward vertically for heating operation. This in order to prevent cold or warm air from blowing directly on the body.

Night quiet mode (cooling only)Lowers the operation sound of the outdoor unit automatically by 3dB(A) by removing a jumper wire on the outdoor unit. This function can be deactivated if the jumper wire is reinstalled on the outdoor unit.

Indoor unit silent operationLowers the operation sound of the indoor unit by 3dB(A). This function is useful when studying or sleeping.

Outdoor unit silent operationLowers the operation sound of the outdoor unit by 3dB(A) to ensure a quiet environment for the neighbourhood.

Comfortable sleeping modeIncreased comfort function that follows a specifi c temperature fl uctuation rhythm.

Powerful modeIf the temperature in the room is too high/low, it can be cooled down/heated quickly by selecting the ‘powerful mode’. After the powerful mode is turned off, the unit returns to the preset mode.

Super multi plusUp to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode.

Multi model applicationUp to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor units can individually be operated within the same mode.

Twin/triple/double twin application2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if they have different capacities. All indoor units operate within the same mode (cooling or heating) from one remote control.

Drain pump kitFacilitates condensation draining from the indoor unit.

Photocatalytic deodorising fi lterRemoves airborne dust particles, decomposes odours and restrains the reproduction of bacteria, viruses, microbes, this to ensure a steady supply of clean air.

Air purifi cation fi lterRemoves airborne dust particles and prevents the propagation of bacteria and viruses to ensure a steady supply of clean air.

Air fi lterRemoves airborne dust particles to ensure a steady supply of clean air.

Double thermostat functionControls the temperature via a sensor on the air conditioner or via a sensor on the remote control.

Whisper quietDaikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the neighbourhood.

Fan speed steps Allows to select up to the given number of fan speed.

Centralised controlCentralised control to start, stop and regulate several air conditioners from one central point.

TimerAllows to preset the air conditioner to start/stop at a specifi ed time.

108

Page 111: Residential & Commercial · 2020-03-26 · Naamloze Venootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW BE 0412 120 336 RPR Oostende Heating and Air Conditioning Systems

Naamloze Venootschap

Zandvoordestraat 300

B-8400 Oostende, Belgium

www.daikin.eu

BTW BE 0412 120 336

RPR Oostende

w w w . d a i k i n a f r i c a . c o m

H e a t i n g a n d A i r C o n d i t i o n i n g S y s t e m s

R E S I D E N T I A L & C O M M E R C I A L C ATA L O G U E 2 0 0 8

ÉEPCEN08-020&ËÍ

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.

ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.

Daikin units comply with the European regulations that guarantee the safety of the product.

Daikin Europe N.V. participates in the Eurovent Certifi cation Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certifi ed data of certifi ed models are listed in the Eurovent Directory. Multi units are Eurovent certifi ed for combinations up to 2 indoor units. Rooftops are not within the scope of the Eurovent Certifi cation Programme.

The present catalogue is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this catalogue to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fi tness for particular purpose of its content and the products and services presented therein. Specifi cations are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this catalogue. All content is copyrighted by Daikin Europe N.V..

Daikin products are distributed by:

EPCE

N08

-020

• 0

4/20

08 •

Cop

yrig

ht ©

Dai

kin

The

pres

ent

publ

icat

ion

supe

rsed

es E

PCEN

07-0

20Pr

inte

d in

Bel

gium

by

Lann

oo (w

ww

.lann

oopr

int.

be),

a co

mpa

ny w

hose

con

cern

fo

r th

e en

viro

nmen

t is

set

in t

he E

MA

S an

d IS

O 1

4001

sys

tem

s.Re

spon

sibl

e ed

itor:

Dai

kin

Euro

pe N

.V.,

Zand

voor

dest

raat

300

, B-8

400

Oos

tend

e

Resid

ential &

Co

mm

ercial CA

TA

LO

GU

E 2

00

8

W W W. D A I K I N A F R I C A . C O M