Report on practical training at C- DOT ABOUT C-DOT BRIEF HISTORY : - The Center for Development of Telematics (C-DOT) is the telecom technology development center of the government , It was established in August 1984 as an autonomous body. It was vested with full authority and total flexibility to develop state-of-the-art telecommunication technology to meet the needs of the Indian telecommunication network. The key objective was to build a center for excellence in the area of telecom technology . ORGANIZATION : - The management of C-DOT has a three-tier structure: - The governing Council: provides policy guidelines and approves the annual budget of the center. The Steering Committee: has the role of reviewing and monitoring the performance of the center. The Project Board: is responsible for the implementation of C-DOT’s project and the day-to-day function of the center. OBJECTIVES : - Work on telecom technology products and services.

Report on Practical Training at C

Embed Size (px)

Citation preview

Page 1: Report on Practical Training at C

Report on practical training at C-DOT

 ABOUT C-DOT BRIEF HISTORY : -

The Center for Development of Telematics (C-DOT) is the telecom technology

development center of the government , It was established in August 1984 as an

autonomous body. It was vested with full authority and total flexibility to develop state-

of-the-art telecommunication technology to meet the needs of the Indian

telecommunication network. The key objective was to build a center for excellence in the

area of  telecom technology .

ORGANIZATION : -

The management of  C-DOT has a three-tier structure: -

The governing Council: provides policy guidelines and approves the annual budget of the center.The Steering Committee: has the role of  reviewing and monitoring the performance of the center.The Project Board: is responsible for the implementation of C-DOT’s project and the day-to-day function of the center. 

OBJECTIVES : -

       Work on telecom technology products and services.       Provide solutions for current and future requirements of telecommunication and

converged networks including those required for rural application.       Provide market orientation to R & D activities and sustain C-DOT as center of

excellence.       Build partnerships and joint alliances with industry , solution provides, telcos and

other development organizations to offer cost effective solution .       Support telcos and service provides in the introduction of new technologies ,

features and services by optimal utilization of installed network.

 

MANPOWER : -

Page 2: Report on Practical Training at C

       Electronic Design automation (EDA) Tools for hardware and ASIC Design       Case Tools for Development and testing of software        Capative labs        Computing center       Pilot production plant       Existing manpower –907       Planned Manpower - 963

The Center has state-of-the-art development environment comprising client/

server network of RISC workstation, latest software development tools and very mature

and effective development ad support methodologies, Extensive use is made of case

tools, object-oriented methodologies, software metric etc.

The jobs have the latest test and measurement instrument, microprocessor  development

system and prototyping facilities.

ACHIEVEMENTS : -

       C-DOT Technology based system from 200 lines to 40,000 lines capacity in operation

       More than 30,000 C-DOT  Exchange totaling approximately 25 million telephone lines installed and operational in field

       Deployed telecom equipment value of Rs.7500 crore       Significant technology transfer and royalty earnings        Technology development with low capital investment        Wide porfolio technologies, products and solution        Created large reservoir of technical manpower in telecom        Established a technology transfer process for production by multiple

manufacturers

The C-DOT DSS  FAMILY

GENERAL

            C-DOT DSS MAX is a universal digital switch can be configured for different

application as local, transit or integrated local and transit switch. High traffic or capacity

of 40000 lines  as local exchange or 15000 trunks as Trunk automatic exchange.

The design of C-DOT DSS MAX has seen by a family concept because of it’s

advantages like standardized components, commonality in hardware, field hardware that

Page 3: Report on Practical Training at C

used minimum number of cards, standard cards, racks, frames, cabinets and  distribution

frames are used which facilitated flexible system growth that make C-DOR DSS MAX

easy to maintain and highly reliable.

FLEXIBLE ARCHITECTURE

            C-DOT DSS is a modular and flexible digital switching system which provides

economical means of serving metropolitan, urban and rural environments. It include all

important feature and compulsory services, required by the user  with option of up

gradation to add new feature  and services in future. The architecture for the C-DOT DSS

is such that it is possible to upgrade a working C-DOT Single Base Module.(SBM) or

Multi Base Module (MBM)exchange  to provide Integrated Services Digital  Network

(ISDN) service  by adding minimum addition hardware modules while continue to having

existing hardware units. Another factor of architecture Remote Switching Unit(RSU). Is

support ISDN. This RSU provides switching facility locally even in case of failure of the

communication path to the  parent exchange.

The resources, which depend upon the number of terminal, are provided within

the basic growth unit the Base Module. Base Processors are provided for handling call

processing locally. In a small system application, these processors independently support

call processing, exchange operation and maintenance function.

ARCHITECTURE OF C-DOT DSS MAX

C-DOT DSS MAX exchanges can be configured using four basic modules.

1. Base Module

2. Central Module

3. Administrative Module

4. Input Output Module

MDF                       SBM CONFIGURATION

Structure of C –DOT DSS MAX

Page 4: Report on Practical Training at C

HARDWARE ARCHITECTURE

 

 

 

 

CENTRALMODULE

 

 

AM

 

BM1

BMn

PBAX LINES

ANALOG TRUNKS

DIGITAL TRUNKS

DIGITAL TRUNKS FROM RSU

ISDN INTER-FACES (BRI/PRI)

ADP

IOM

DISK

VDU

PRINTERR

TAPE

 

 

Page 5: Report on Practical Training at C

C-DOT MAX  exchange can be configured using four basic modules:-

1.BASE MODULE(BM)2.CENTRAL MODULE(CM) C3.ADMINISTRATION STRATIVE MODULE(AM)4.INPUT OUTPUT MODULE(IOM&IOP)

 

(a)   BASE MODULE (BM) : -

         The Base Module  is the basic growth unit of the  system . It interfaces the external

world to  the switch. The interfaces may be subscriber lines, Along and  digital trunks.

Each Base Module can interface up to 2024 terminations. The number of Base Modules

directly corresponds to the exchange size. It carries out majority of call processing

function and in a small exchange application, it also carries out operation and

maintenance function with the help of Input-Output Module.

The Basic functions of a base modules are:-

1. Analog to digital conversion of all signals on analog lines and trunks.

Page 6: Report on Practical Training at C

2. Interface to digital trunks and digital subscriber.

3. Switching the calls between terminals connected to the same Base Module.

4. Communication with the AM via the CM for administrative(i.e. Call processing )

functions.

5. Provision of special circuits for call processing support e.g. Digital

6. Tones, announcement, MF/DTMF Senders/receivers.

7. 6.Provision for local switching Unit(RSU) as well as in case of Single Base

Module Exchange(SBM_RAX).

There are two types of Base Modules :-

1. Single Base Modules(SBM)

    2.   Multi Base Module(MBM)

In SBM exchange configuration, the Base Module acts as an independent

switching BM directly interface with the Input Output Module for bulk data storage,

Page 7: Report on Practical Training at C

operations and maintenance function. Clock and synchronization is provided by a source

within the BM. It is a very  useful application for small urban and rural environments.

The Base cabinet houses total 6 frames:-

         Terminal Unit (TU, Top 4  Frames) system and provides connection to 1500 lines and 128 trunks. In such a configuration ,the

         Base Processor Unit ( BPU,5th frame)         Time switch unit (TSU)

There are following four terminals units:-

1. ANALOG TERMINAL UNIT (ATU):-

The Analog Terminals Unit (ATU) is used for interfacing 128 analog termination

which may be lines or trunks and providing special circuits as conference 

announcements and terminal tester. It consists of terminal cards, which may be a

combination of Analog Subscriber Line Cards, Analog Trunk card & some Special

Service Cards.

(a)   Analog Subscriber Ling Cards : -

Two variants of subscriber line cards as LCC(Line Circuit Card) or CCM(Coin

Collection Monitering) with interfaces upto 8 subscribers. Analog to digital conversion is

done by per channel CODEC according to A-Law of Pulse Code Modulation so we can 

say that it for the  subscriber connected for subscriber to exchange.

A unit has 16 line cards so     16*8=128 subscribers.There  are 4 unit so 4*128= 512 subscribers.4 cards make 1 Terminal Group(TG) so TG = 4.

(b)   Analog Trunks Cards :-

Analog trunk cards interface analog inter exchange trunks which may be of three

types as TWT,EMT & EMF. These interfaces are similar to subscriber Line Cards, with

only difference that the interfaces are designed to scan/drive events on the trunks as

predefined signaling requirement.

Page 8: Report on Practical Training at C

(c) Signaling Processor Cards : -

SP Processes the signaling information received from the terminals cards. SP

processes the signaling information consists of scan/drive function like original detection,

answer detection, digit reception, reversal detection etc. The validated events are reported

to Terminal interface controller for further processing.

(d) Terminal interface controller (TIC) Cards : -

TIC controls the four terminals group ( TG) of 32 channels and multiplex  them to

form a duplicated 128 channels, 8 mbps link towards the Time Switch. For Signaling

information of 128 channels it communicates with signaling processor to receive/send the

signaling event on analog terminations. It also uses to communicate with  BPU.

(e) Special Service Cards : -

A Terminal unit has some special service cards such as  Conference (CNF) cards

to provide six party conference. Speech Samles from five parties are Terminal Test 

Controller (TTC) card is used to test analog terminal interfaces via the test access relays

on the terminal cards.

Announcement controller card provides 15 announcement on board cast basis.

(2) DIGITAL TERMINAL UNIT( DTU ) : -

Digital terminal unit is used to interface digital trunks, i.e. used between the

exchanges. one set of Digital Trunks Synchronization (DTS) Card along with the Digital

Trunk Controller(DTC) card is used to provide one E-1 interface of 2mbps.

Each interface occupies one TG of 32 channels and four such interfaces share 4

TGs in a DTU. Here Terminal Unit Controller (TUC) is used of TIC and DSP cards. Out

of 32 channels, 30 for voice communication and remaining two for Signaling  and

Synchronization.

Page 9: Report on Practical Training at C

In DTU 4 TGs are there so total number of unit are 4*30 = 120 units in DTU.

(3) # 7 or Signaling Unit Module(SUM) : -

It is used to support SS7 protocol handlers and some call processing function for

CCS7 calls.

SS7 capability in C_DOT DSS MAX exchanges is implemented in the form of a

SS& Signaling Unit Module (SUM).

            The sum hardware is packaged into a standard equipment frame, similar to that of

terminal unit. It is a module by itself and contains global resources. It interfaces with the

Time Switch via Terminal Unit Controller (TUC) on a 128 channel PCM link operating

at 8mbps.

 

ISDN

To support termination of BRI/PRI interfaces and implementation of lower layers of

DSSI Signalling protocol. They are used as carriers to transport bulk volume of data.

With the increasing use of internet access, the use of ISDN interface is likely to go up as

it provides the reliable access to the user at the rate of 64/128kbps. It is of two types i.e.

circuit switched voice and data and packet switched data. In circuit switch the traffic is

routed through ISDN and is packet switched data the traffic is routed through PSPDN.

REMOTE SWITCH UNIT : -

In this time switch card BMs are replaced  by Enhanced Switch Cards(ETS). It is

used when the e exchange is at a far distance from the central module. It can modified

BM via 2 mbps digital links. Analog and Digital trunk interfaces are also implemented in

RSU to support direct perenting of small exchanges from RSU. Instead of perenting it to

the main exchange. RSU is an autonomous exchange capable of local call completion.

Only the even numbered BMs can be configured as RSU i.e. a maximum 16 RSUs are

Page 10: Report on Practical Training at C

possible in C-DOT DSS MAX-XL  and 8 RSUs in MAX-L Maintenance and operation

function are handled by the host exchange. 

          Remoter Switch Unit                                                 Normal BMs

1.Tpe of connectivity  used is                        1.Type of connectivity is through  E-1                                  data cables                                                    cards of 2mbps and E-3 cards of 32Mbs.

2. Contains Time Switch  Cards.                   2.Contains Enhanced Switch Card.3. Situated at a Distance.                               3. Should be in side of CM.

TIME SWITCH UNIT (TSU):-

Time Switch Unit (TSU) implements three basic function as time switching with

in the Base Module, routing of control message within the Base Module and across Base

Module and support services like DTMF circuit, answering circuit, tones etc. These

functions are performed by three different functional unit, integrated as Time Switch

Unit  in a single frame. i.e.

 SERVICE UNIT : -

            It is integrated around three different cards as Tone Generator with Answering

Circuit (TGA), Service circuit interface Controller (SCIC) and DTMF Controller, (MFC)

Card. These three forms TGs towards Service Circuit interface (SCI). SCI multiplexes

these  TGs together with another terminal group from the Base Message. Switch (BMS)

to form a 128 channel, 8 Mbps link & send it to the Time Switch.

BASE MESSAGE SWITCH (BMS) : -

            Base Message Switch (BMS) route the control message with in the Base Module,

across different Base Module and also Administrative Module via the Central Module. It

is implemented around two cards as Message Switch Controller (MSC) with the Message

Switch Device (MSD) with 16 HDCL links.

Page 11: Report on Practical Training at C

            So total 22 HDLC channels are implemented for communication with the Base

Processor, Time Switch Controller, Service Circuit interface Controller with in the BM. It

transfer the message between the Base processor and these controllers.

To supports 8,00,000 BHCA,MSC AND MSD cards are replaced by a high

Performance Switch(HMS) with  high speed upto 750 Kbps, 32 bit microprocessor.

TIME SWITCH ( TS ) : -

The Time Switch complex is implemented using three different functional cards

as multiplexer/demultiplexer (TSM),Time Switch (TSS) and Time Switch Controller

(TSC). The Time Switch complex performs time switching with in the Base Module : -

Four 128 channel multiplexed link from four different terminal units which may

be any combination of ATU,DTU,#7SU AND ISTU.

One 128 channel multiplexes BUS from the Service Circuit interface Controller

(SCIC) in the Time Switch Unit.

Three 128 channel link to support on board three party conference circuit (3*128).

BASE PROCESSOR UNIT :-

            Base Processor Unit (BPU) is the master controller in the Base Module. It is

impleted as a duplicated controller with memory units. These duplicated sub-units are

realised in the form of the following cards :-

1.      Base Processor Controller(BPC) Cards.2.      Base Memory Extendra (BME) Card.

1. Base Processor Controller(BPC) Cards : -

 BPC control time switching within the Base Module via the Base Message

Switch and the Time Switch Controller. It communicates with the Administrative

processor via Base Message Switch for operations and maintenance functions. In a SBM

configuration,BPC directly interface with the Alarm Display Panel and the input Output

Module.

Page 12: Report on Practical Training at C

            To support 8,00,000 BHCA, the BC card is replaced by High performance

processor card.(HPC) i.e. Protocol Handler Card (PHC) which contain 26 slot,8slot for

the power supply, 2 for memory and remaining 10 for message switching.

 

2. Base Memory Extender (BME) Card : -

It is for the storage purpose i.e. saving memory purpose. It can store up to  16 bits

CENTRAL MODULE

Central module is responsible for space switching of inter-Base Module calls,

communication between Base Module and Administrative Modules, clock distribution

and network synchronization. For these function central module has a Space Switch,

Space Switch Controller, a Administrative Processor and a Central Message Switches

CMS(A,B,C,D). In a 32 Base Module configuration , there are 64 bit parallel buses

carrying the voice information  from Base Module to the Central Module, and also the

Switched information in the reverse direction.

The complete control conceptually is shown in following figure : -

Space switch controller

Administrative processor

CMS

C

CMS

D

CMS

B

Page 13: Report on Practical Training at C

CMS

A

Space switch

Concept Control  Scheme for Space  Switch

The administrative processor communicates with the IOPs  which act like a

central storage. Administrative processor is also connected to Central Message Switches

CMSA and CMSB through which AP communicates to SSC. The SSC is connected to all

the CMSs (A,B,C,D) so as to communicate with all the BMs through these Central

Message Switches (CMS_A,B,C,D).

 There are two types of Central Module : -

 1.CM-XL (Extra Large) 2.CM-L(large)

 

Page 14: Report on Practical Training at C

Central Module Large (CM-L)

Central Module Extra Large (CM-XL)

1.There are one BTU (Base Terminal Unit)    and one  SSU (Space Switch Unit)

2.The 8 MHz clock may be locally generated at the Space Switch Clock (SSK) card in CM-L. or may be derived by using Network Synchronisation Equipment(NSE) in this.

 3. In CM-L,CM provides connectivity to 16 BMs.

 4.Each message switch is a high performance message routing block, implemented by using high speed 16 bit microprocessor Motorolla Company (MC).

1.There are two BTU and two SSU.

  2.The 8 MHz clock may be locally generated at the Central Clock (CCK) Card in CM-XL. Or may be derived by using Network Synchronization Controller Card.

 3. In CM-XL, CM provides connectivity to 32 BMs.

 4.Each message switch is a high performance message routing block, implemented  by using high speed 16 bi microprocessor Motorolla Company (MC).

Each BM interfaces with CM via two 512 channel parallel buses as BUS-0 and

BUS-1,each operating at 4 Mbps. These buses carry voice information of 512 termination

of the Base Module towards CM. In the reverse direction, after space switching has been

done in the Space Switch under the control of Space Controller (SSC), the same buses

carry the switched voice information for 512 termination towards BM. Thus, in a 32 Base

Module configuration, there are 64 parallel buses carrying  the voice information from

Base Modules to the Central Module, and also the switched information in the reverse

direction.

CM FRAME ORGANIZATION

                                                                    CM

Page 15: Report on Practical Training at C

 

 

 Space Switch                                       Administrative                                       Central

Switch                                                  Processor                                             Message

1.Space Switch Mux                            1.Bus Interface                1.CMS A

   Demux Card(SSM)                           Controller(BIC) Card                  (For TS0,Bus 0)

2.Space Switch                                    2.Bus interface                  2.CMS B

   Switch Card(SS)                                  CPU(BIC) Card                          (for TS0,Bus1)

3.Space Switch                                    3.Memory(MEM)                        3.CMS C

   Clock Card (SCK)                                                                               (For TS1,Bus 0)

 (Space Controller Unit)                                                                            4.CMS D

1.CPU Card                                                                                             (for TS1,Bus 1)

2. Bus Interface                                                                                    1.Message Switch

3.Bus Interface                                                                           Controller Card

Device(BID) Card                                                                                  2.Message Switch

4.Memory                                                                                               Device Card(MSD)

Page 16: Report on Practical Training at C

(MEM) Card                                                                                

5.Terminal Cards

CM HARDWARE DISTRIBUTION :-

CM Hardware is distributed in following frames : -

Bus Terminal Unit (BTU) Frame

Space Switch Unit (SSU) Frame

Space Switch Controller Unit (SCU)

Administrative Processor Unit (APU)

 

Page 17: Report on Practical Training at C

BUS TERMINATION UNIT : -

It contains Multiplexer and Demultiplexer. It is Basically an Interface Unit

Between the BM and Space Switch. There are two buses-Bus 0 and Bus 1.Bus 0 contain

all even time slots and Bus 1 carries all odd time slots. Bus is terminated from the Base

Modulation. It controls the Space Switching between Base Modules.

BTU insert the message CMS to BMS and vice versa. 

FUNCTION : -

(a)    Caters to maximum 16 BMD in release one.

(b)   Multiplexes the data for Space Switching.

(c)    De multiplexes the Switched Bus.

(d)   Distributed 8 MHz clock and 8 KHz sync. To BMs.

(e)    Acts as a Gateway for CMS by message extraction/insertion scheme

Page 18: Report on Practical Training at C

Types of cards used : -

1. Space Switch Mux Card(SSM) : -  It multiplexes two BMs data.

2. Space Switch Mux Termination Card (SMT) :- It is used in an unequipped. SSM slot in

the BTU frame to avoid any noise generated due to termination of a bus from BM in

BTU frame. It offer 2A load at 5V.

3. Power Supply Card : - It supplies power to the cards and unit it work as a load sharing

mode in each bus.

4. Space switch unit :  Space Switch provide connectivity between two subscriber of two

different BMs on time slot basis. It is responsible for switching of cards between various

base modules

FUNCTION : -

(a)    Establishes Inter Base Module Switching.(b)   Caters for 16*16 Base Module switching.(c)    Implements two 16*16 switching; one for bus 0 and other for bus 1.(d)   Provides redundancy as copy 0,copy1(switch duplicated)

Types of cards used : -

1. Space Switch Switch Cards (SSS) : -

            The switch card forms the part of the space switch which is situated in the Central

Module. Each SSS Card caters for four base modules (16*4 switch in CM).

2. Space Switch Termination Card ( SST) : -

            It provides proper termination to the MUX data bus received from 16 space

Switch MUX Cards. The card is used if corresponding SSS slot is unequipped.

3. Space Switch CU Bus Termination Cards (SCT) : -

Page 19: Report on Practical Training at C

It is used in Space Switch Unit and  Space Switch Control Unit frames of CM. It

terminates CPU, address, data and control signals.

4. Power Supply Cards : -

SSU employs 4 cards for supplying power and it is used in BPU,TSU,IOP.

3. Space Switching Controller Unit(SCU) : -

            It is a CPU complex and interfaces with space switch and clock for controlling the space switch. SSC communicates with the CMSs which in turn enable the SSC to communicate with the BMs. It contain Power Unit

FUNCTION : -(a)    Controller for the Switch

         Time slot management and allocation         Switch monitoring for sanity         Switch diagnosis

(b)   Communication b/w the central message switch and Aps, BMs(c)    System clock generation(d)   Management of power alarms in BTU,SSU and SCU

Space Switch(SS) and Space Switch Controller (SSC) : -

1. In order to take care of the large number of interface signals, the switch portion of CM

is divided into three stages viz. MUX stage, Switch stage and DEMUX stage. The MUX

and DEMUX stage are implemented on single card to provide the Base Module to

Central Module interface in each direction. Interfacing and switching are controlled by

SSC which provides control signals for the MUX/DEMUX cards and the space Switch

cards.

2.MUX/DEMUX Cards extract the information from time slots 0 and 1 of Bus 0 and Bus

1 from the Base Modules. These time-slot carry control message from each base Module

and these messages are sent to the Central Message Switch (CMS). The CMS sends these

message to the Space Switching controller (SSC) on a 128 kbps link to control space

switching based upon the information.

Page 20: Report on Practical Training at C

3. Four 512-channel buses from four BMs are multiplexed to form a 2048-

channel,16Mbps multiplexed BUS which is sent to both copies of the Space Switch

Switch Card. Space switching  of these 2048 channels is done based upon the switching

information received by Space Switch Controller (SSC) from CMS

Central Message Switch (CMS) : -

            It consists of four different message switches and each one of them is

implemented by using high speed 32 bit microprocessor. All Central Message Switches

(CMS 1,2,3 & 4) are used for routing of messages across the Base Modules. Only CMS1

and CMS2 interface with the Administrative Module for routing control message

between Base Processors and Administrative Processor.

Type of Cards used : -

1.      CPU Complex

         Space Switch Controller Card (SSC) (CPU) : - This is to serve as central processing

engine for the C-DOT DSS both in the BM & the CM mode. It coordinates system

activities and perform call processing functions. It is used as Base Processor (BP) in

the BM& as administrative processor (AP) and Space Switch Controller (SSC) in

CM.

         Bus interface-CPU(BIC) Card : - It is used to access memory and space switch in

plane copy-0 & copy –1.

         Bus interface Device (BID) Card : - It along with bus interface CPU (BIC) card

provides the cross connection  b/w duplicate CPU’s (controller) an duplicate device

(memory) in such a way that any one failure either at  CPU or at device does not

bring down the whole processor complex.

         Memory Card (2MB) : -It provides storage space and interfaces to a standard 6800

CPU bus. Both word & byte accessory are possible on the memory space.

Page 21: Report on Practical Training at C

2. Switch Interface

         BIC Card

         Bid Card                                                               

         Space Switch Controller Termination (SCT)           

3. System Clock and PSU errors

         Space Switch Clock Card(SCK) : - It is the source of clock signal to the space switch

switch cards & the space switch mux cards which constitute the space switch. It is

used for the control of timing and for synchronizing of the space switches.

Administrative Processor Unit (APU) : -

         Status of all module of the exchange is maintained by  the AP and whenever a

problem is reported required action is initiated to clear the problem. All the global

resource like trunks. Time slots etc are managed by the A.P. Directory to equipment

number translation for the establishment of a call is performed by AP

All global data is managed by the AP. In a multimodule exchange all the call        

processing. Administration and  maintenance function are supervised by the AP. 

Function of APU : -

1. All administrative function in the system

2. Interaction with SSC through central message switches CMS(A,B) (SSC/BM to

IOP via AP).

3. Communication to ADP.

4. Administrative Processor (AP) somewhat similar to BP.

5. Maintain status of all modules of the exchange.

6. Initiate whenever a problem is reported required action to clear the problem.

Page 22: Report on Practical Training at C

7. Switch over of copies, diagnostic of faulty units and put in service units which are

out of service etc, are initiated and supervised by the AP.

8. Manage all the global resource (like trunks,ts etc.)

9. Perform directory to equipment no. translation  for the established of a call.

10. Connects of exchange to the operator through IOP.

11. Handle the man-machine communication.

12. During initialization of the multimode exchange AP gather initialization request

from different BMs, collects code and data from IOP and send it to corresponding

BM’s.

Types of Card used  : -

1.      CPU Complex (APU)         CPU Card         BIC Card         BID Card          Memory Card(2MB)

 

2. Central Message Switch-CMS (A,B,C,D)

Message Switch Controller Card (MSC)

Message Switch Device Card (MSD)

CALL PROCESSING

GENERAL CONCEPT

There are five function steps of call processing including the location of the

originating and terminating equipment. These steps are : -

         Origination : - Origination begins when the subscriber line goes off hookor incoming trunks seized. It receives the incoming digits, selects the digit analysis tables, and determines the screening information for this call.

         Digit Analysis: - It interprets the digits it receives from origination ,select a destination for each call, and passes the dialed digits to routing.

Page 23: Report on Practical Training at C

         Routing/Screening:- Routing uses the destination information from digit analysis and screening information origination to select the terminating trunk group or line.

         Charging : - It uses the charging information from routing to expand the charging data into a formate usable by call accounting process.

         Termination : - The last step in call processing is termination. Termination Processor is different for calls destined for lines and call destined for trunks.

 

Trunk termination : - A trunk member of the trunks group is selected based on a

predetermined pattern. After selection the digits are out pulsed to the distant office.

Line termination : - The line identified in routing is checked to determine the line has any

special features. Ringing is applied to the line if applicable or the special feature is

activated.

 

SIGNALING

What is Signaling ?

Signaling refers to the exchange of information between call components required

to provide and maintain service.

            As users of the pubic Switched telephone network, we exchange signaling with

network element all the time. Examples of signaling between a telephone user and the

telephone network include. Dialing digits, providing dial tone, accessing a voice mailbox,

sending a call waiting tone, dialing *66(to retry a busy number), etc.

            Signaling system 7 is means by which element of the telephone network exchange

information. Information is conveyed in the form of messages. Signaling System 7

messages can convey information such as :

SS7 is characterized by high-speed packet data, and out-of-band signaling.

Page 24: Report on Practical Training at C

OUT OF BAND SIGNALING

Out-of-band signaling is signaling that does not take place over the same path as

the conversation.

            We are used to thinking of signaling as being in-band. We hear dial tone, dial

digits, and hear ringing over the same channel on the same pair of wires. When the call

completes, we talk over the same path that was used for the signaling. Tradition

telephony used to work in this way as well. The signals to set up a call between one

switch and another always took place over the same trunk that would eventually carry the

call. Signaling took the form of a series of multi frequency (MF) tones, much like touch

tone dialing between switches.

Out-of-band signaling information. This channel is called a signaling links are

used to carry all the necessary signaling messages between nodes. Thus, when a call is

placed, the dialed digits, trunk selected, and other pertinent information are sent between

switches using their signaling links, rather than the trunks which will ultimately carry the

conversation. Today, signaling links carry information at a rate of 56 or 64 kilobyte per

second (kbps).

It is interesting to note that while SS7 is only used for signaling between network

elements, the ISDN D channel extends the concept of out-of-band signaling to the

interface between the subscriber and the switch. Win ISDN service, signaling that must

be conveyed between the user station and the local switch is carried on a separate digit

channel called  the D channel. The voice or data which comprise the call is carried on one

or more B channels.

Why Out-of-Band Signaling ?

Out of-band signaling has several advantages that make it more desirable than tradition in-band signaling:

         It allow for the transport of more data at higher speeds (56 kbps can carry data much faster than MF outpulsing)

         It allow for signaling at any time in the entire duration of the call, not only at the beginning.

Page 25: Report on Practical Training at C

         It enables signaling to network element to which there is no direct  trunk connection.

BASIC OF SIGNALING SYSTEM # 7

Common channel Signaling System no.7 (i.e.,SS7 or C7) is a global standard for

telecommunication defined by the international Telecommunication Union(ITU),

Telecommunication Standardization Sector(ITU-T).The standard defines the procedures

and protocol by which network element in the public switched telephone network (PSTN)

exchange information over a digital signaling network to effect wireless(Cellular) and

wireline call setup, routing control. The ITU definition of SS7 allow for national variants

such as the American Nation Standards Institute (ANSI) and Bell Communication 

Research (bellcore) standards used in North America and the European

Telecommunication Standards Institute(ETSI) standard used in Europe.

The SS7 network and protocol are used for :         Basic call setup, management and tear down         Wireless service such s personal communications services (PCS),wireless

roaming, and mobile subscriber authentication.         Local number portability (LNP)         Toll-free(800/888) and toll(900) wireline services          Enhanced call features such as call forwarding, calling party name/number

display,and three-way calling          Efficient and secure worldwide telecommunication.

 Signaling Links

SS7 messages are exchanged between element over 56 or 64 kilobit per second

(KBPS) bi-directional channels called signaling links. Signaling occurs out-of-band on

dedicated channels rather than in-band on voice channels. Compared to in band signaling

out-of-band signaling provides.

         Faster call setup times(compared to in-band signaling using multifrequency (MF) signaling tones)

         More efficient use of voice circuits         Support for intelligent Network(IN) services which require signaling to

network element without voice trunks (e.g., database system)         Improved control over fraudulent network usage

Page 26: Report on Practical Training at C

Signaling Points

Each signaling point in the SS7 network is uniquely identified by a numeric point

code. Point codes are carried in signaling messages exchanged between signaling point to

identify the source and destination of each message. Each signaling point uses a routing

table to select the appropriate signaling path for each message.

There are three kinds of signaling points in the SS7 network.

 SSP(Service Switch Point)

 STP (Signal Transfer Point)

SCP (Service Control Point)

 

SS7 Signaling Points

SSPs are switches that originate terminate, or tandem calls. An SSP sends signaling message to other SSPs to setup, manage, and release voice circuit required to complete a call. An SSP may also send a query message to a centralized database (an SCP) to determine how to route a call (e.g., a toll-free 1-800/888 call in

North America). An SCP sends a response to the originating SSP containing the routing number(s) associated with the dialed number. An alternate routing number may be used by the SSP if the primary number is busy or the call is unanswered within a specified time. Actual call features vary from network and form service to service.

Network traffic between signaling points may be routed via a packet switch called an STP. An STP routes each incoming message to an outgoing signaling link based on routing information contained in the SS& message. Because it act as a network hub, an STP provides improved utilization of the SS7 Network by eliminating the need for direct links between signaling points. An STP may perform global title translation, a procedure by which the destination signaling point is determined from digits present in the signaling

Page 27: Report on Practical Training at C

message (e.., the dialed 800 number, calling card number, or mobile subscriber identification number). An STP can also act as a “firewall” to screen SS7 messages exchanged with other networks.

Because the SS7 network is critical to call processing, SCPs and STPs are usually deployed in mated pair configuration in separate physical location to ensure network-wide service in the event of an isolated failure. Links between signaling points are also provisioned in pairs. Traffic is shared across all links in the linkset. If one of the links fails, the  signaling traffic is rerouted over another link in the linkset. The SS7 protocol provides both error correction and retransmission capabilities to allow continued service in the event of signaling point or link failures.

SS7 Signaling Link Types

Signaling links are logically organized by link type ('A' through 'F') according to their uses in the SS7 signaling network.

SS7 Signaling Links Types

A link: An “A”(access) link connects a signaling end point (e.g., an SCP or SSP) to an

STP. Only messages originating from or destined to the signaling end point are

transmitted on a “A” link.

B link: A “B” (bridge) link connects an STP to another STP.

            Typically, a quad of “B” links interconnection peer(or primary) STPs (e.g., the

STPs from network to the STPs of another network). The distinction between a “b” link

and a “D” link is rather arbitrary. For this reason, such links may be referred to as “B/D”

links.

Page 28: Report on Practical Training at C

C links : A “C”(cross) link connects STPs performing identical function into a mated pair. A 'C' link is used only when an STP has no other route available to a destination signaling point due to link failure(s). Note that SCPs may also be deployed in pair to improve reliability; unlike STP’s however mated SCPs are not interconnected by signaling links

D link: A “D” (diagonal) link connects a secondary (e.g., local or regional) STP pair to a

primary (e.g.; inter-network gateway) STP pair in a quad-link configuration. Secondary

STPs within the same network are connected via a quad of “d” links. The distinction

between a “B” link and a “D” link is rather arbitrary. For this reason, such links may be

referred to as “B/D” links.

E links : An “E” (extended) links connects an SSP to an alternated STP.”E” links provide

an alternate signaling path if an SSP’s “home” STP cannot be reached via an “A” link.

“E” links are not usually provisioned unless the benefit of a marginally higher degree of

reliability justifies the added expense.

F link : An “F” (fully associated) link connects two signaling end points (i.e.,SSPs and

SCPS). ”F” links are not usually used in network with STPs. In network without STPs,

“F” links directly connect signaling points.

ISDN

(INTEGRATED DIGITAL SERVICE NETWORK TERMINAL UNIT)

            One of the four ATUs/DTUs in a Base module be replaced by ISTU to provide

Basic Rate Interface (BRI)/Primary Rate Interface in C-DOT DSS. It is directly

connected to TSU on 8 Mbps PCM Link.

INTRODUCTION

            ISDN is comprised of digital telegraphy and data transport services offered by

region telephone carries ISDN involves the digitization of the telephone network which

permits voice, data, text, graphics ,music ,video and other source material to be

transmitted over exiting telephone wires. The emergence of ISDN represent an efforts to

Page 29: Report on Practical Training at C

standardize subscriber service user/network interface and network and inter network

capabilities.

ISDN application includes high speed image application , addition telephone lines

in home to serve the telecommuting industry, high speed file transfer and video

conferencing. Voice service is also an application for ISDN.

Architecture of ISDN Terminal Unit

            In C-DOT DSS architecture the ISDN interface are terminated on a new add on

terminal unit as ISTU. A maximum of 256 bearer channels are provided by integrating

one ISTU which can be configured to support any combination of BRI or PRI interfaces.

If the requirement of PRI/BRI interfaces more than 256 bearer channels ,one or more.

ISTU, can be integrated in C-DOT DSS with the option of equipment them in the same

BM of distributed across different BMs in the exchange.

            The architecture also support in signaling providing time slots for switching

channels, carrying data & voice.

SERVICE

There are two types of services associated with ISDN:-

1. BRI

2. PRI

1. ISDN BRI Service 

The ISDN Basic rate interface(BRI) Service offers Two B channels and one

D channels (2b+D). BRI B channels service operated at 64 Kbps and is carry user data.

BRI d channels service operates at 16 Kbps and is meant to carry control and signaling

information, although it support user data transmission under certain circumstances. The

Page 30: Report on Practical Training at C

BRP also provides for framing control and other overhead, bringing its total bit rate to

192 Kbps.

The BRI physical layer specification is International Telecommunication 

Standard Section (ITU-T). (Formerly the consultative committee for international

telegraph and telephone (CCITT)

2. ISDN PRI SERVICE

The ISDN traffic is of two distinct types:-

         Circuit switched voice & data         Primary Rate Line (PRL)

Basic Rate Line (BRL) Card

            The BRL is an interface to the switching system supporting 8 U-interface towards

the user. It interfaces with the ISDN Terminal Controller(ITC)/Switching Network for

signaling and switching of voice and packet information.

            The function of the BRL card include HYBRID for 2 to 4 conversion and echo

cancellation monitoring of lines status, it’s activation and deactivation, over voltage

protection (for protect the exchange and the BRL card from high voltages),test access.

Primary Rate Interface Line Card(PRL)

            The PRL Card is an interface to terminate a 2.048 Mbps link ,using symmetric

twisted pair cables with characteristic impedance of 120 ohms.

            Each PRL card form a terminal group (TG) and a maximum of 8 PRL, cards can

be accommodation in  each ISTU.

ISDN USER PART( ISUP )

The ISDN User Part(ISUP) defines the protocol and Procedures used to set-up.

Manage, and release trunk circuit that carry voice and data calls over the public switched

Page 31: Report on Practical Training at C

telephone network(PSTN). ISUP is used for both ISDN and non-ISDN calls. Calls that

originate and terminate at the same switch do not use ISUP signaling.

Basic ISUP Call Control

1. When a call is placed to an out-of-switch number, the originating SSP transmits an

ISUP initial address message (IAM) to reserve an idle trunk circuit from the originating

switch to the destination switch:-

         The IAM includes the originating point code, destination point code, circuit

identification code dialed digits and, optionally, the calling party number and

name. In the example below, the IAM is routed via the home STP of the

originating switch to the destination switch

         Note that the same signaling links are used for the duration of the call unless a

link failure condition forces a switch to use an alternate signaling link.

2. The destination switch examine the dialed number, determines that it serves the called party, and that the line is available for ringing. The destination switch transmits an ISUP address complete message  (ACM) to the originating switch

         (via its home STP) to indicate that the remote end of the trunk circuit has been reserved. The destination switch rings the called party line and sends a ringing tone over the trunk of the originating switch. The STP routes the ACM to the Originating switch.

         Which connects the calling party’s line trunk to complete the voice circuit from the calling party to the called party. The calling party hears the ringing tone on the voice trunk.

In the example shown above, the originating and destination switches are directly connected with trunks. If the originating and 

Destination switches are not directly connected with trunks , the originating switch transmits an IAM to reserve a trunk circuit to an intermediate switch. The intermediate switch sends an ACM to acknowledge the circuit reservation request and then transmits an IAM to reserve a trunk circuit to another switch.

This processes continues until all trunks required to complete the voice circuit from the originating switch to the destination switch are reserved

Page 32: Report on Practical Training at C

3. When the called party picks up the phone, the destination switch terminates the ringing

tone and transmits an ISUP answer message (ANM) to the originating switch via its

home STP

         The STP routes the ANM to the originating switch          Which verifies that the calling party’s line is connected to the reserved trunk and,

if so, initiates billing.

4. If the calling party hangs-up first, the originating switch sends and ISUP release

message (REL) to release the trunk circuit between the switch

         The STP routes the REL to the destination switch         If the called party hangs up first, or if the line is busy, the destination switch

sends an REL to the originating switch indicating the release cause(e.g.; normal release or busy).

5. Upon receiving the REL, the destination switch disconnects the trunk from the called

party’s line, sets the trunk state to idle, and transmits an ISUP release comlete message

(RLC) to the originating switch

         To acknowledge the release of the remote end of the trunk circuit. When the originating switch receives(or generated) the RLC

         It terminates the billing cycle and sets the trunk state to idle in preparation for the next call.

ISUP message may also be transmitted during the connection phase of the call (i.e.; between the ISUP Answer (ANM) and Release (REL) messages.

ALARM DISPLAY PANEL (ADP)

The ADP is used in the C-DOT to display the status of the system in single base

module configuration . It can also be used with a two base module system .

            The status is displayed on light emitting diodes (LEDs)and seven segment LED

display. Fresh faults are reported on the panel by blinking the LEDs accompanied by an

audio alarm to draw the attention of the operator in turn is expected to acknowledge the

faults .

Page 33: Report on Practical Training at C

ADP is a microprocessor based hardware unit which is attached to the BP (in

SBM) or AP(IN MBM) by HDLC(HIGH DATA LINK CONTROLLER) link for

providing audio visual indication of system faults . a seven segment display shows the

count of lines and trunks currently faulty.  

ALARM PHILOSOPHY :-

In a C-DOT DSS, there are three categories :--non urgent => green LEDs .-urgent        => orange LEDs .-critical       => red LEDs .

FUNCTIONAL DESCRIPTION :-

The ADP is housed on three cards :-

1. Controller card .

2. display card .

3. power supply card .

1.      Controller card :-

It is a subdivided into following blocks:-

(a)   CPU LOGIC :-

It generates clock required by microprocessor, buffers for buffering for CPU

address and data bus , power on reset logic to generate the signal.

(b) MEMORY :-

   Occupies address space RAM.

(C) DISPLAY CARD INTERFACE :-

Consist of logic which generates the various strobes for the registers on the

display card  

Page 34: Report on Practical Training at C

(D) INTERRUPT AND WATCHDOG DOG :-

The sources of interrupt for the CPU are :-

(i)                  Real time timer (ii)                Acknowledge switch (iii)               LED test switch (iv)              The two HDLCs.

The sources for generate one interrupt line for the microprocessor.

(e) INPUT /OUTPUT PORTS AND AUDIO ALARM :-

input port is used to determine the configuration of the system and the source of

the interrupt. Output port is used for cleaning the various interrupts & for enabling the

audio alarm. The audio alarm is implemented using a piezo-electric buzzer 

(f) COMMUNICATION INTERFACE:-

Consists of clock generator for the HDLs.

INTERCONNECTION

Various interconnection required in the ADP are as follows :-

 1. link connection: The two links from the two copies of BPs are terminated on the back

panel.

2. Controller card to display card connection : This connection is made with a 34 pin flat

cable also carries the power for the display card .

3. Power connection from power supply card to controller card : A four wire cable

connect the power from the power supply card to controller card  through four pin

connector.

4. Connection for switches and beeper => switches => Reset switch

Page 35: Report on Practical Training at C

LED test

switch                                                                                                            Acknowledge

switch

connected through twisted pair wires.

5. 48V connection to power supply card =>

            48V from the exchange battery is the ADP through a two pin  power  connector that passes through a power ON/OFF switch .

SYSTEM CAPACITY

INTRODUCTION

The capacity of C-DOT DSS is defined in terms of the following parameters:

        The termination capacity express as the number of lines and trunks         The amount of traffic (in erlangs) that can be switched      The number of Busy Hour Call Attempts (BHCA) that can be processed with a

given call-mix while meeting the overall service quality requirements.

This section indicates the maximum capacity of different system element as well

as that of  complete exchange, equipped to its ultimate termination capacity. It has been

ensured that the specified parameters are valid to meet overall reliability objectives for

the C-DOT DSS as specified in ITU-T recommendation.

TERMINATION CAPACITY

A terminal Card is the basic system element. It interfaces/terminates the lines and

trunks. The next higher element is a Terminal Unit. The types of terminal card and

terminal unit used in C-DOT DSS along with its function are already explained in chapter

‘3’ &’4’. Termination capacity of BM is 488 analog lines and that of LM in 768 analog

lines. A BM can be concentrated with 2 LM’s  to provide maximum termination capacity

of 2024

Page 36: Report on Practical Training at C

Analog lines. Incase of BM, a maximum of 256 B channels are provided at the

cost of 512 analog lines. One to one replacement of Base channel is planned in immediate

future. Base Module and Line Module are the highest level of system elements. Each

Base Module has four Terminal Units whereas a Line Module has six Terminal Units.

A maximum of 16 BMs can be connected in MAX-L and 32 BMS can be

connected in MAX-SL configurations.

Table summaries the termination capacities of the various system element of C-DOT

DSS MAX.

Page 37: Report on Practical Training at C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.NO. SYSTEM ELEMENT TERMINATIONCAPACITY

DESCRIPTION

1 TERMINATION CARD  

1.1 Analog Line Card LCC-8 analog subscribers

    CCM-8 CCB subscriber with last two

    ports supporting16 KHz metering

pulse

1.2 Analog Trunk Card TWT or EMF -8 Trunks

1.3 A set of DTS/DTC Cards One,2 Mbps E-1 link as CAS/CSS7

trunks

1.4 #7 PHC Card (SHM) 8 Nos. protocol handlers/signaling

links

1.5 ISDN-BRI Cards 8BRI (2B+1D) interface I.e. 16 Bearer

Channels

1.6 ISDN-PRI Cards One PRI (308+D) interface I.e. 30

Bearer Channels

2 TERMINATION UNIT/FRAM  

2.1 Analog TU (ATU) 16 analog terminal

cards(LCC,CCM,EMF,TWT) to

    support any combination of lines and

Trunks in 

    multiple of eight termination

2.2 Digital TU (DTU) 4 Nos. 2 MbpsE1 links asCAS/CSS7

2.3 #7Signalling Unit Module (SUM) 64 Nos; 37 protocol handlers/signaling

links

2.4 ISDN-Terminal Unit (ISTU) 256 Bearer channels to be configured

as BRI, PRI

    or any combination of them.

3 BASE MODULE/RACK  

3.1 Link Module(line) 480 analog subscribers. A maximum

256 Bearer

    Channels for ISDN interface can be

provided at the

    Cost of 128 subscriber lines.

3.2 Line Module 768 analog subscribers. A maximum

of two line

    module connected with Base Module

support

    2024 Lines

3.3 Base Module(Analog Trunks) 488 analog trunks

3.4 Base Module (Digital Trunks) 15 Nos., 2Mbps E1 links

as"CAS/CCS7

3.5 Base Module (Analog+ Digital) Three possible configuration as 360

Page 38: Report on Practical Training at C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXCHANGE CONFIGURATION

C-DOT DSS MAX can be configured to support any combination of lines and

trunks, for different application in the network as local Exchange, Local cum Tandem

Page 39: Report on Practical Training at C

Exchange. Trunks Automatic Exchange(TAX) or Integrated Local cum Transit (ILT)

Exchange.

In this maximum configuration, upto 40,000 lines and 5,500 trunks are supported

when configured as Local/Local cum Tandem. When configured as TAX. 14,500 trunks

are supported.

Termination Capacity of Exchange Configuration

S. No. Exchange Configuration Termination Capacity Description1.

 

Single Base Module(SBM) 1500 lines and128 trunks. The trunks may be analog and/or digital. The no. of trunks can be increased at the cost of reducing subscribers.

2.

 

 

Multi Base Module (DSS-MAX)

(i) MAX-XL

Ideal configuration to support 40,000 lines and 5500 trunks with 20 line BMs and 12 Trunks BMs. The trunk capacity can be increased by 450 at the cost of 2,000 subscriber or vice versa

(ii) MAX-L Ideal configuration to support 20,000 lines and 2700 trunks with 10 line BMs and 6 Trunk BMs. The trunk capacity can be increased by 450 at the cost of2,000 subscriber and vice versa.

3. Remote Switching Unit (RSU) 2,000 Subscriber Lines. Trunk interface at the

cost of  subscriber lines.

4 Multi Base Module TAX 14,500 Trunks

Note : Out of the total equipment capacity, a maximum of 30,000 Lines may be Remote

Subscriber through RSUs in MAX-XL whereas 14000 lines.

SOFTWARE ORGANIZATION

The software is written in high level language ‘C’ & distributed over various

processors and is structured as a hierarchy of virtual machines. The software features are

implemented by communication processes. The operating system provides

communication facilities such that the processes are transparent to heir physical locations.

Page 40: Report on Practical Training at C

Resource are identified as ‘global’ or ‘local’ depending upon their distribution in

the system. The resource which depends upon the number of terminal are provided within

the basic growth module. The basic module processor are provide for handling call

processing locally. In a small system application , these processor independently  support

call processing, exchange operation and maintenance functions. Central facilities are also

provided to avoid repetition of large data & memory intensive functions.

E.g., Processor architecture is characterized by distributed control & message based communication in order to achieve a loosely-coupled network for a flexible system architecture.

ROLE OF SOFTWARE IN C-DOT DSS

INTRODUCTION

The main feature of the software architecture of DSS-MAX are as:

Distributed architecture to ma the distributed control architecture

Layered architecture with loosely coupled modules & well defined message

interfaces.

Use of high level language

Modular design with each layer providing higher of abstraction

Time critical processes in assembly language

These feature help in to achieve the following objectives:

Simplicity in design

Increased reliability due to fault tolerant software

Flexibility with option of up gradation to add feature & service

Efficiency and strict time check

Ease of Maintainability

 

 

Page 41: Report on Practical Training at C

 

HARDWARE

 

 

 

 

 

 

 

 

Page 42: Report on Practical Training at C

C-DOT DSS MAX Layered Software Architecture

SOFTWARE SUBSYSTEMS

The main subsystem of C-DOT  DSS MAX are as :

C-DOT real Time operating system

Peripheral Processors subsystem

Maintenance subsystem

Database subsystem

Administration subsystem

IOP subsystem

Call Processing subsystem

These subsystem are responsible for providing the following basic services:

1. CDOS :

It is the operating system & provides the following function :

Process management

Resource management

Interrupt handling

Online & offline debugging

2. Peripheral Processor subsystem :

It controls all the telephony software. It also carries out the commands given by

the Base Processor for generating suitable telephony events. Another function is to carry

out all the maintenance related test function on hardware. It consists of 8-bit

microprocessors programmed in assembly language

3. Call processing subsystem:

Page 43: Report on Practical Training at C

It receives the information about telephony event that occur outside the exchange.

It processing this incoming information & gives commands to the peripheral processors

for interconnecting subscriber through the switching network. A special feature is to

generate Exhaustive Call Event Record for every call.

4. Maintenance subsystem:

It provides the following function:

         Initialization         System integrity         Switch maintenance         Terminal interface         Human interface

5. Administration subsystem:

It consist of traffic, billing exchange performance measurement & human

interface functions. It also provides online software patching capability. It is responsible

for maintaining  a large number of traffic records on the basis of information received by

it through Call Event Records. Over 200 man-machine commands are provided for these

operations.

6. Database Subsystem:

It provides for the management of global data.

The main objectives are:(a)    Easy access(b)   Quick access(c)    Transparency(d)   Consistency(e)    Security(f)     Synchronization

BASIC SERVICE IN DSS MAX

Page 44: Report on Practical Training at C

The most important function of a DSS switch is  to process subscriber calls.

Subscribers’ call can be classified as line-to-line, line-to-trunk, and trunk-to-trunk. A lint-

to-line is a call that starts on a line served by a DSS switch and terminates to another line

served by the same switch. The BMs involved in the call will perform almost 95% of the

total call processing function.

During a line-to-line call, the origination BM detects when a subscriber’s

telephone receiver as been picked up. The BM provides the dial Tone and then removes

the Dail

Tone when first digit is dialed. It then collects and analyzes the dialed digits.

Next, the BM sends a request to the AM for a call path. The terminating BM locates the

subscriber line for the line-to-line call and provides ringing.

When AM has selected an available path. It alerts the CM to set up link between

the BM’s. The CM provides call paths between BM’s and carries all internal system

communications.

The function of BM, AM, and CM in trunk-to-trunk call are basically the same as

line-to-line call described above except that the originating BM detect a trunk seizure

rather than a subscriber picking up the receiver. Also, the terminating BM locates as

available trunk instead of line.

            The above scenarios may differ slightly, if the call involves both and trunk.

Lint-to-Line call can be of two types:

        INTRA_BM: When both subscriber lines connected to same BM. This doesn’t

require use of CM.

        INTER_BM: When both subscriber lines are to different BMs. This requires use

of the CM.

OTHER SERVICE PROVIDED BY MAX

Page 45: Report on Practical Training at C

The MAX provides the following features apart from processing of a telephone call:

Number identification Service:

Calling Line Identification Presentation (CLIP): The Calling Party’s details are

given to the user along with the incoming calls.

Calling Line Identification Restriction(CLIR): With this service the calling party

may restrict presentation of it’s number to the called party.

Calling Line Identification Restriction Override (CLIRO): The subscriber with

this facility receives the details of the calling party even if it has asked for it’s

restriction.

Malicious Call Identification (MCID): During conversation the subscriber can use

a procedure to identify the malicious caller.

Call offering supplementary Service:

        Call Forwarding ?Unconditional(CFU)L It allows the user to forward all

incoming calls to another number.

        Call Forwarding Busy(CFB): It allows the user to forward all incoming calls to

another number if the user’s number is not free.

        Call Forwarding No Reply (CFNR): It allows user to forward all incoming calls

to another number if the user doesn’t respond in a fixed number of rings.

 Call completion Services:

Call Waiting:  A Subscriber engaged in a call, is given an indication that another

caller is trying to call him up. The  user can then talk to a caller by keeping the

other holding.

Call Hold: This allows the user to put th call into wait for the being and initiate or

accept a new call. The user can retrieve the call put on hold whenever required.

Multi Party Services:

Page 46: Report on Practical Training at C

Three Party Conference: It enables the user to establish, participate in and control

a simultaneous communication involving the user and two other parties. The

served user can disconnect one party, disconnect the three-way conference or

communicate privately with one of the parties.

Multi Party Conference: It allows uses to establish and control a conference

involving at the most 6 users. The conference controller may add, drop, isolate,

and reattach parties from  the conferences.

Misc. Service:

Hot Line(Timed): It allows the subscriber to establish calls to a pre-registered

number. After getting the dial tone, if the subscriber doesn’t dial any number for a

minimum amount of time, then he is connected to the pre-registered number. If

the subscriber dials a number, then normal connection is established.

Hot line(Without Time-Out): As soon as the subscriber lift the handset, the call to

the pre –registered number is established. Normal outgoing calls can’t be made.

Reminder Call/Alarm Services: The subscriber can receive a call by the exchange 

at a specified time. This service is available in two forms: (i) Semiautomatic Form

,where the booking is manual through an operator, or (ii) Automatic Form, where

booking is done automatically, through a control procedure.

Subscriber Controlled Call Restriction Service : In this service; the user can deny

all call at a time deny various levels of originations from a line. Outgoing calls

can also be restricted by the mean of a password.

Instruction Barring Service: With this service a subscriber can enjoy an

uninterrupted call, e.g., in case of data transmission.

 

POWER PLANT OF C-DOT DSS MAX

From the power supply bus bar power is tapped through cables to each suite separately. In this there is five modules, each having 200amp. As input. In this, AC is input and DC is output. In this input is between 340-475 V and output is 48V. There are two batteries if

Page 47: Report on Practical Training at C

one is not conduct than other is used. These are connected together if both are disconnected than till 15-20 minutes power is supplied. From the rectifier, which derives 48V DC from 440V AC. Power cables are terminated on the DC distribution panel (DCDP). From the DCDP, power cables run along the cable runways and ladders and terminated on the power distribution panel(PDP). Distribution panel consists of two bus bars for –48V, one each for copy 0 and copy 1 equipment. Similarly there are  two bus bars for ground.

            For each base module cabinet, the power i.e.-48V is tapped twice one for each

plane through a fuse. Whenever the fuse blows off the LED, which is connected in

parallel glows on the FBI card, and an audio alarm is given at a centrally located point.

SUMMARY 

            C-DOT DSS is a modular and flexible Digital Switching System which provides economical means of serving metropolitan, urban and rural environment. It incorporated all important feature and mandatory service, required by the user with option of up gradation to add new features and service in future. The architecture for the C-DOT DSS is such that  it is possible to upgrade a working C-DOT SBM or MBM exchange to provide ISDN service by adding minimum addition hardware modules while retaining existing hardware units.

            C-DOT DSS MAX is a universal digital switch which can be Configured for different application as local, transit, or integrated local and transit switch. The design of C-DOT DSS MAX has envisaged a family concept. The advantages of family concept are standardized components, commonality in hardware, documentation, training, installation and field support for all product and minimization of inventory of spares. Infact this Modular design has been consciously achieved by employing appropriate hardware, software, and equipment practices.

            Software is written in high level language ‘C’ and distributed over various processor and is structured as a hierarchy of virtual machines. It can be distributed over appropriate controllers. The Software failures are implemented by communicating processes.

REFERENCES

    C-DOT  Library   C-DOT DSS MAX General Description   www.cdot.com   A  Book Digital Switching System by Sayed Ali 