Remotely Troubleshooting Embedded Systems using High Quality Log Files. ESC 313. 3/28/2012. Dave Stewart, PhD Director of Software Engineering InHand Electronics [email protected] www.inhand.com. Objective. - PowerPoint PPT Presentation
Citation preview
ESC 313
Remotely Troubleshooting Embedded Systems using High Quality Log Files
Dave Stewart, PhDDirector of Software Engineering
InHand Electronics [email protected]
3/28/2012
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Objective
2
If a deployed system fails, have sufficient data captured to identify root cause and find a fix, without having to replicate the issue Necessary for embedded systems that behave differently
in the field than in the lab Essential in critical failures where replicating the issue is
impossible Eliminate lengthy debug cycles that result when failures
are observed but little data is available to understand the issues
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Primary Goals
3
Improve quality of log files Standardize format for every module that logs data
Ensure consistent and complete information It only takes one missing piece of information to make
it impossible to pinpoint a root cause from a log file. Standardize process
Determining log info should be a design step Don’t rely on programmers to add in debug info on-
the-fly; such ad-hoc methods lead to poor-quality log files.
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Key Aspects
4
Text Logs Capture system configuration and boot-time information Print version numbers of every module
Binary Logs Continually collect data about a running system Manage limited non-volatile memory and performance
Parser Back at the lab, automatically convert binary logs to text Visualize data trends to spot anomalies
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Text Logs of Boot and Initialization
5
Most OS already provide a mechanism for printing at boot-up However, inconsistency in the design of kernel
initialization code or driver code often means only partial information is printed, and not necessarily the most important information
In this class, focus on WHAT to capture, not HOW Use the OS mechanism Augment with macros to standardize Make sure key information is printed Avoid printing wasteful info, so that boot time does not
slow down due to logging
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Issues with Typical Boot Logs
6
Typical Log Entryfprintf(logfile,“SPI Driver Init”);
Information that should be printed, but is missing: Which SPI port? How is it being configured? Which pins is it using? How is the control register initialized? Did the right version get built and integrated? Can the right source code be found quickly?
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Use Macros to Auto-Generate Info
7
#define LOG_ENTER() \fprintf(logfile,“[%s/%d %s] %s %s %d\n”, \
__FILE__,__LINE__,__FUNCTION__,\__DATE__,__TIME__,getpid())
Which produces and entry similar to the following in the log[file.c/87 xxx_init] Feb 20 2012 11:33:07 8880
Simply place LOG_ENTER() as first line in every driver or module initialization function
Information such as filename, line, and date help identify exactly which module was loaded.
PID helps link thread IDs to functions, which could become useful when debugging and PID of failed thread is available.
Version is especially important if customers have ability to download patches or updates, to know precise state of the code.
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Print Key Configuration Information
8
When a module or driver is initialized, print value of every configurable item If there is data that could be changed on an individual
platform, like in a registry of configuration file, then that information may be useful in remotely debugging an issue
Be concise and complete Print statements slow down boot process, so don’t be
verbose. Just print values with minimal information that allows correlating back to source code
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Example of Printing Key Information
9
Too verbose, not enough infoSPI driver initialized in master mode, Port 2Speed set to 20 MbpsFramesize 16 bytesClock on GPIO 12, Frame on GPIO 11MOSI on GPIO 13, MISO on GPIO 14
More concise, yet more detail (i.e. +filename/line):[spi.c/64] SPI_2M 20Mbps fs=16 GPIO={12,11,13,14}
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Print Thread and Interrupt Information
10
Info is needed when parsing a run-time log Allows correlating a thread or interrupt ID back to the source
code. To the extent possible, print an entry each time a thread is
created and terminated It should include Thread ID, function name, time stamp, and any
information to distinguish it if multiple threads of same function are created
This is not always practical A thread that is created and destroyed repeatedly needs to be
skipped In this case, consider it run-time information as described later
Similarly, print information for each interrupt handler that is initialized
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Run-Time Log Files
11
Continuously collect data on every aspect of the system Budget the amount of space needed to store log files early
during system design Decide what percentage of CPU time can be allocated for this
function. 2% to 5% overhead is reasonable.
Store data in non-volatile memory E.g. flash, SD card, or SSD drive For retrieval either by opening unit, or through an existing
customer communications link Do not store any classified data in the log files!
Important in military or other classified system
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
High Quality Log Files
12
“High Quality” means all required data to debug an issue has been captured It eliminates reliance on imprecise customer
descriptions of the problem or what led to the problem. Avoids the need to have to replicate the issue to
debug it Replicating an issue is simply a means to collect more
clues. In some critical systems this is absolutely essential
E.g. the Airplane “Black Box”
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
High Quality Log Files
13
Provides the data needed to re-run in simulation If debugging using traditional means is necessary to
identify root cause, a high quality log file provides the data needed to re-run in simulation
Carefully review every detail that goes into the log A log file contains poor information if it only provides
minimal or partial clues to the actual problem
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Concise Log Files
14
Memory reserved for log files can fill up quick Optimize memory usage as part of the design.
Be cryptic to save memory Cryptic is fine as long as there is easy way to decipher the
log file. For example:
“Average of velocity for past 30 seconds = 3.49231” uses 40 bytes of memory
“av30=3.49231” uses 12 bytes of memory
Both the above provide equal amount of information, but second one is more concise, and log is searchable by unique acronym “av30”
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Concise Log Files
15
Even more concise, store in binary: 0xaa30 0x405F8202
Uses 6 bytes of memory
16-bit number as a key allows for 65536 separate types of log entries
32-bit floating point number is only 4 bytes of data Create code or scripts to parse data, and quickly
search or filter desired data Example provided later
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
What Information Must be Logged?
16
Every key item needed to “replay” what happened Next few slides define what are those key items
Periodic Timestamps Microsecond resolution is desirable. Millisecond resolution is essential. Relative time, stored as a 16-bit or 32-bit number is
often acceptable Don’t use more than 4 bytes per timestamp, or memory
will fill up too quickly. Time-of-day
If time-of-day is available, periodically log it.
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Logging Key Items: System State
17
Periodically log the “state” of the system, including the following: The “mode” or “state” for any code that is built as a
finite state machine The current value and setting of every GPIO pin Current value of every key peripheral register Current value of key global variables Current value of sensor readings Current value of any controller output
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Logging Key Items: Communication
18
Summary of every communication message that is sent or received: Includes Ethernet, WiFi, USB, SPI, etc. Save key information, such as sender or receiver, size
of message, command or message type. For short messages (i.e. a few bytes) include entire
message. For longer messages, include first few data bytes
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Logging Key Items: I/O
19
Every driver output E.g. Instrument the stream interface, so that every write
operation is captured Save device, port, and value written
Inputs or reads If state changes made based on an input, then log that
input If inputs are stored as part of the periodic state that is
logged, then no need to separately log the input Every configuration change
If a key device configuration register is changed, then log the new value written
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Logging Key Items: Interrupts
20
Every Interrupt Timestamp of entry into and exit from ISR IRQ number on entry If this is a shared IRQ, which device was interrupting
Memory Optimization For interrupts that occur very frequently (such as timer
interrupt), skip the timestamp and use just codes, e.g. 2 bytes on entry, 2 on exit, to not fill up log memory
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Logging Key Items: Context Switches
21
Every Context Switch Timestamp of entry into each thread Thread ID Timestamp of any entry into idle state or thread
Instrument the OS The line of code to log this event needs to be in the
operating system scheduler, right before the context switch occurs
Some OS already provide hooks at this specific spot
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Completeness of Logs
22
Avoid Gaps Log files are most effective when there are no “gaps” in
information This happens when one or more modules do not log
like they should Put code to log information into kernel code
E.g. in drivers or operating system functions, where they cannot be touched or changed by applications
Logging is then enabled always for everything Do not provide an ability to disable it. Software can be certified with logging enabled, as long
as the logging threads are part of the design documents
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Wow! Isn’t that way too much to log?
23
A lot of data, but not TOO much Sample calculation next slide
Size of flash storage needed proportional to complexity of the embedded system For smaller systems, memory may only need to be
measured in KB or MB For more complex architectures, may need GB
Not free, but usually affordable For smaller sizes, external EEPROM for under $1 Leverage the fact that external flash can be obtained for
under $1 per GB in bulk
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Example – High Performance System
24
Typical of 32-bit ARM with RTOS State of system, 400 bytes, once per second Messages, 16 bytes per message, 500 messages per second I/O Driver Writes, 12 bytes per call, 200 times per second Interrupts, 12 bytes per interrupt, about 800 times per second Context Switches, 8 bytes per switch, 200 times per second
Above scenario = 400+12*800+12*200+8*200+16*500= 22 kBytes per second= 1.3 Mbytes per minute= 80 Mbytes per hour= 2 GBytes per day, assuming 100% 24/7 usage
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Example – Low-End System
25
Typical of an 8-bit system with only a few kbytes of RAM State of system, 30 bytes, every 10 seconds Messages, 4 bytes per message, 1 message per second I/O Driver Writes, 12 bytes per call, 10 times per second Interrupts, 4 bytes per interrupt, about 10 times per second Context Switches, 4 bytes per switch, 5 times per second
Above scenario = 3+4+12*10+4*10+4*5= 187 bytes per second= 11 kBytes per minute= 673 kBytes per hour= 16 MBytes per day, assuming 100% 24/7 usage
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Optimizing Memory Usage
26
Take into account use-cases Many embedded systems only used a few hours per day
Detect when system is idle or is in a steady state Have a code to indicate idle or “same as previous entry”
Use a circular buffer in the flash Discard oldest data. Usually only last few minutes to
hours of a log are needed
Based on above, actual requirements could be just a fraction of what was computed on prior slides
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Managing Log Files
27
Store multiple small files instead of one big file. E.g. start a new file every 5 minutes. Makes it easier to retrieve only partial logs within
specific time periods. Use a DRAM FIFO
Most logging is done in kernel space, where file access is not available
Write to DRAM FIFO, overhead is negligible. Periodically, have a high-priority thread read a large
block of data from FIFO and write it to log file.
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Performance of Logging
28
Execution time to save log is minimal With proper optimization of log code, the logged data should
not use more then 2 to 5% of the processing power. E.g. Can write SD at 1MByte/sec, 2% overhead means
maximum 22KByte/sec. “5% overhead is too much”
Only an issue on systems that are almost overloaded Consider the cost of NOT having this data when a problem
occurs in a field unit that needs to be fixed. Trade-offs: the 5% overhead may be more valuable than
another thread that uses more than that much CPU power
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Verifying Log before Deployment
29
Test the mechanism Have QA team inject a fault Run the system that captures the log Can the software team find the problem given just the log?
Optimizing dominating log statements If log file fills up with one piece of non-critical information
because it executes very often, optimize the number of bytes needed, or reduce how often it gets logged
Boot system with and without log enabled How much longer was boot time with logs enabled? Rule of thumb, it should not be more than about 10%
longer
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Parsing a Log File
30
Create code or scripts This can’t be a manual process
Convert binary log file to text Example of a flexible mechanism on next slide
Add filter capabilities Include or exclude selected codes based on issue being
debugged Add analysis functions
Extra data values for certain codes and graph them Find minimum or maximum values for certain variables
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Example
31
Next few slides show sample code: Log format Log macros FIFO stream or Buffered I/O Define codes for each log item Instrument sources Dump-to-file thread Run code to produce log file Parser Filter
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Log Format
32
Create multiple data structures for each different data size. E.g. // Example Log Format 1typedef struct { uint16_t code; uint16_t value; // for both 8-bit and 16-bit} log_1_t;
// Example Log Format 2typedef struct { uint16_t code; uint16_t tstamp; uint32_t value; // for 32-bit values} log_2_t;
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
FIFO Stream
33
Use a FIFO stream to write to file FIFO needed if logging is in kernel space, but writing to file done from
application space Buffered I/O appears to provide same function, but it doesn’t!
It does the writes in kernel space and as part of the process calling the log function, which could affect real-time performance!
Use real-time scheduling analysis to determine correct priority of thread writing to file.
Write a few bytes at a time to log area in memory Structures should be kept 32-bit word aligned to minimize overhead
Write to file when log area exceeds a threshold E.g. when file system block size is reached Or “every 16 blocks” Trade-off – don’t wait too long, because if there is a hard crash,
anything in RAM not on disk is lost.
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Log Macros
34
#define LOG_ENTRY_1(_code,_val) { \ log_1_t l; \ l.code = _code; \ l.value=(uint16_t)_val; \ fifo_insert(&fifo,(uint8_t *)&l,sizeof(l));}
#define LOG_ENTRY_2(_code,_val) { \ log_2_t l; \ l.code = _code; \ l.value=(uint16_t)_val; \ l.tstamp = (clock() ); \ fifo_insert(&fifo,(uint8_t *)&l,sizeof(l));}
#define LOG_SYNC() LOG_ENTRY_2(CODE_SYNC,CODE_SVAL)
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Define Codes for Each Log Item
35
#define CODE_I 1#define CODE_X 2#define CODE_Y 3
// SYNC Code used to insert framing // and to recover in case of corruption#define CODE_SYNC 0xCAFE#define CODE_SVAL 0xBEEF1234
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Instrument Sources
36
Snippet of instrumented code. After values change, log them.
x = x+i;y = y*x;LOG_SYNC();LOG_ENTRY_1(CODE_I,i);LOG_ENTRY_1(CODE_X,x);LOG_ENTRY_2(CODE_Y,y);
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Dump to File Thread
37
Periodically when buffer exceeds threshold, write to filewhile(1) {
fifo_wait();fifo_getremove(&cfifo,block,BLOCK_SIZE); fwrite(block,BLOCK_SIZE,1,fp);fifo_remove(&cfifo,block,BLOCK_SIZE);
} Two options for waking up this thread:
Polling: If data collected pretty regularly, then predict when to wakeup.
Signaling: design fifo_insert() to generate a signal when threshold for writing to file is reached. fifo_wait() waits for that signal.
Use In-place fifo_remove That is, fifo_getremove() retrieves pointer, doesn’t actually copy data. fifo_remove() only adjusts the pointers to show ‘done’.
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Run code to produce log file
38
File produced is binary. Here is sample hexdump:000000 fe ca b2 00 34 12 00 00 01 00 00 00 02 00 10 00000010 03 00 64 01 30 03 00 00 fe ca 16 02 34 12 00 00000020 01 00 01 00 02 00 11 00 03 00 c8 02 30 36 00 00000030 fe ca 7a 03 34 12 00 00 01 00 02 00 02 00 13 00000040 03 00 2c 04 90 05 00 00 fe ca de 04 34 12 00 00000050 01 00 03 00 02 00 16 00 03 00 90 05 60 7a 00 00000060 fe ca 42 06 34 12 00 00 01 00 04 00 02 00 1a 00000070 03 00 f4 06 c0 6d 00 00 fe ca a6 07 34 12 00 00000080 01 00 05 00 02 00 1f 00 03 00 58 08 40 4a 00 00000090 fe ca 0a 09 34 12 00 00 01 00 06 00 02 00 25 00
Sync Pulses shown in yellow Allows validating that log file not corrupted Easily identify start of a cycle Use to “fast forward” through a log file, since each one has a relative time-stamp
on it
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Parser – Setup
39
Define a look-up table Print format for each type of log entry is provided in table
E.g.:typedef struct { int code; int type; char *fmtstr;} log_entry_t;
log_entry_t table[] = { {CODE_SYNC, 2, "Sync Pulse @ %d\n"}, {CODE_I, 1, "i= 0x%02X\n"}, {CODE_X, 1, "x= 0x%02X\n"}, {CODE_Y, 2, "y= 0x%04X @ %d\n"},};
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Parser – Code
40
On PC, run through entire log file Convert binary to ASCII text
E.g.p = &buffer[0];while (!eof) { code = *(uint16_t *)p; idx = find_idx(code);
switch (table[idx].type) { case 1: { log_1_t *l = (log_1_t *)p; printf(table[idx].fmtstr,l->value); p += sizeof(log_1_t); } break;
case 2: { log_2_t *l = (log_2_t *)p; printf(table[idx].fmtstr,l->value,l->tstamp); p += sizeof(log_2_t); } break; }}
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Sample Output from Parser
41
Sync Pulse @ 348i = 0x00x = 0x10y = 0x0330 @ 356Sync Pulse @ 704i = 0x01x = 0x11y = 0x3630 @ 712Sync Pulse @ 1062i = 0x02x = 0x13y = 0x0590 @ 1068Sync Pulse @ 1418i = 0x03x = 0x16y = 0x7A60 @ 1424
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Filter as Needed
42
Use scripts or code. Simplest example is to look at just one value:
prompt> ./parse logfile.bin | grep "x=" x= 0x10 x= 0x11 x= 0x13 x= 0x16 x= 0x1A x= 0x1F
Can also create parser to generate data in a form that can be graphed Enables viewing trends, such as for control system variables,
number of events, etc.
DesignWest 2012 – San JoseRemotely Troubleshooting using High Quality Log Files
InHand Electronics, Inc. – www.inhand.com© 2012 Dave Stewart, PhD
Summary
43
Objectives: If a deployed system fails, have sufficient data captured
to identify root cause and find a fix, without having to replicate the issue
Primary Goals Improve quality of log files Ensure consistent and complete information Define a company-wide process
Techniques Text logs for boot-up Binary logs for run-time