FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 919-494 Regency Horizon ® HZ42STE Gas Fireplace 09.15.15 Owners & Installation Manual www.regency-fire.com Tested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. MODELS: HZ42STE-NG10 Natural Gas HZ42STE-LP10 Propane Horizon HZ42ST Product Video - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. • Do not touch any electrical switch: do not use any phone in your building. Leave the building immediately. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach you gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4919-494

Regency Horizon® HZ42STEGas Fireplace

09.15.15

Owners & Installation Manual

www.regency-fire.com

Tested by:Installer: Please complete the details on the back cover

and leave this manual with the homeowner.Homeowner: Please keep these instructions for future reference.

MODELS: HZ42STE-NG10 Natural Gas HZ42STE-LP10 Propane

Horizon HZ42ST Product Video

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch: do not use any phone in your building. Leave the building immediately. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's

instructions. • If you cannot reach you gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNINGFIRE OR EXPLOSION HAZARDFailure to follow safety warnings exactly could result in seriousinjury, death, or property damage.

Page 2: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

2 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 2

To the New Owner:

Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The HZ42STE has been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch. The model HZ42STE has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.

Page 3: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 3

3|

MANUFACTURED MOBILE HOME REQUIREMENTSINFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE

This Regency® product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88 - 2014 / CSA 2.33 - 2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.

This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.

This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Ensure that structural members are not cut or weakened during installation.

Page 4: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

4 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 4 table of contentsSafety Decal ..................................................................5Unit Dimensions ............................................................7Important Message ......................................................8Before You Start ............................................................8General Safety Information............................................8Installation Checklist ......................................................9Locating Your Gas Fireplace .........................................9Clearances ..................................................................10Framing Dimensions.................................................... 11Non-Combustible Facing Installation ..........................12Non-Combustible Requirements .................................13Horizontal Venting .......................................................13Vertical Venting ............................................................13Mantel Clearances.......................................................14Mantel Leg Clearances................................................14Framing & Finishing.....................................................15Unit Assembly Prior To Installation ..............................16Optional Framing Kit ....................................................17Horizontal Vent Deflector Installation...........................19Wall Mount On / Off Switch And Remote Receiver Installation ....................................................20Required For All Installations - Including Proflame Remote Controls ...........................20Vent Restrictor Position ...............................................21Exterior Vent Termination Requirements .....................224” X 6-5/8” Rigid Pipe Cross Reference Chart ............23Venting Introduction .....................................................25Venting Arrangements ................................................25Horizontal Terminations ...............................................26Flex Vent 4" X 6-5/8" ...................................................26Rigid/Flex Pipe Venting Systems.................................27Horizontal Or Vertical Terminations .............................27Horizontal Terminations ...............................................28Rigid Pipe 4" X 6-5/8" ..................................................28Vertical Terminations ...................................................31Rigid Pipe 4" X 6-5/8" ..................................................31Vertical Terminations ...................................................32Rigid Pipe 4" X 6-5/8" ..................................................32

Unit Installation With Horizontal Termination ..............344" X 6-5/8" Venting ......................................................34Unit Installation With Horizontal Termination ..............35Unit Installation With Vertical Termination ...................364" X 6-5/8" Venting ......................................................36High Elevation .............................................................37Gas Line Installation ....................................................37Pilot Adjustment ...........................................................37Gas Pipe Pressure Testing ..........................................37885 S.I.T. Valve Description .........................................37Aeration Adjustment ....................................................37Wiring Diagram ...........................................................38Optional Wall Thermostat Installation ..........................39AC Power Adaptor Installation (For Surefire Systems) 40Optional Wall Thermostat ...........................................40Optional Reflective Panel Installation ..........................41Glass Crystals Or Optional Stones Installation............42Optional Pebbles / Glass Crystal Installation For Firebox Base (Around Burner)..................................................42Optional Log Set Installation........................................43Glass Door Installation ................................................45Safety Screen/ Inner Door Frame Removal/Installation 46Outer Door Frame Installation .....................................47Faceplate Installation...................................................48Operating Instructions .................................................49First Fire ......................................................................49Normal Operating Sounds Of Gas Appliances ............49Lighting Procedure ......................................................50Shutdown Procedure ...................................................50Copy Of Lighting Plate Instructions .............................51Maintenance Instructions.............................................52General Vent Maintenance ..........................................52Glass Gasket ...............................................................52Glass Door...................................................................52Valve Tray Replacement ..............................................53Main Assembly ............................................................55Accessories .................................................................56Warranty ......................................................................59

Page 5: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 5

5| safety decalThis is a copy of the label that accompanies each HZ42STE-NG10 and HZ42STE-LP10 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.

NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible con-nectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli-ances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

SAFETY DECAL

Page 6: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

6 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 6 requirements

5.08: Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements:

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1. Detailed instructions for the installation of the venting system design or the venting system components; and

2. A complete parts list for the venting system design or venting system.

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and

2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

MA Code - CO Detector(for the State of Massachusetts only)

Page 7: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 7

7| dimensions

UNIT DIMENSIONS

(1092mm)

(972mm)

(522

mm

)

(902mm)

(318

mm

)

(388

mm

)15

1 4

Inner/Outer Faceplate 4 Piece Faceplate/Verona Surround

Page 8: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

8 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 8 installation4) This appliance must be connected to the spec-

ified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.

5) Inspect the venting system annually for blockage and any signs of deterioration.

6) Venting terminals shall not be recessed into a wall or siding.

7) Any safety glass removed for servicing must be replaced prior to operating the appliance.

8) To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9) Wear gloves and safety glasses for protection while doing required maintenance.

10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11) Under no circumstances should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12) Installation and any repairs to this appliance should be done by an authorized service per-son. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

13) Do not slam shut or strike the glass door.

14) Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15) The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

IMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe HZ42STE Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU STARTSafe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

GENERAL SAFETY INFORMATION1) The appliance installation must conform with

local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2) The appliance when installed, must be electri-cally grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3) See general construction and assembly in-structions. The appliance and vent should be enclosed.

CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE-CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.

YOUNG CHILDREN SHOULD BE CARE-FULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLI-ANCE. TODDLERS, YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSICAL BARRIERS IS RECOMMEND-ED IF THERE ARE AT RISK INDIVIDUAL IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES.

A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM THE HOT VIEWING GLASS IS PROVIDED WITH THIS APPLIANCE AND SHALL BE INSTALLED FOR THE PROTECTION OF CHILDREN AND OTHER AT-RISK INDIVIDUALS

IF THE BARRIER BECOMES DAMAGED, THE BARRIER SHALL BE REPLACED WITH THE MANUFACTURER'S BARRIER FOR THIS APPLIANCE.

ANY SAFETY SCREEN, GUARD, OR BARRIER REMOVED FOR SERVICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.

Page 9: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 9

9| installation

This includes:

1) Clocking the appliance to ensure the correct firing rate (rate noted on label 26,000 Btu/h (NG), after burning appliance for 15 minutes.

2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in dam-age is not the responsibility of the manufacturer.

INSTALLATION CHECKLIST1) Locate appliance a) Room location (Refer to "Locating Your

Gas fireplace" section) b) Clearances to Combustibles (Refer to

"Clearances" section) c) Mantle Clearances (Refer to "Mantel

Clearances" section) d) Framing & Finishing Requirements (Refer

to "Framing & Finishing" section) e) Venting Requirements (Refer to "Venting"

section)

2) Assemble Top and Side Standoffs (Refer to "Unit Assembly Prior to Installation).

3) Slide unit into place.

4) Install vent (Refer to "Venting Arrangement" sections).

5) Make gas connections (Refer to "Gas Line Installation section).

6) Make electrical connections to receptacle supplied with unit (recommended).

7) Install 4 AA batteries into receiver/switch box or use AC power adaptor supplied with this appliance.

8) See remote control instructions for operation

9) Test the pilot (Refer to "Pilot Adjustment" section).

10) Test Gas Pressure (Refer to "Gas Pipe Pressure Testing" section).

11) Install standard and optional features. Refer to the following sections:

a) Glass Crystals/ Firebeads /Optional Ceramic Stones

b) Optional Firebox Base Pebbles c) Optional Reflective Panels d) Inner door Frame e) Faceplate f) Remote Control or Wall Thermostat

12) Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

LOCATING YOUR GAS FIREPLACE1) When selecting a location for your fireplace,

ensure that the clearances are met as outlined in the "Clearances" section.

2) Provide adequate clearances for servicing.

3) The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood flooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

4) The Direct Vent Gas Fireplace can be installed as follows:

Model # Position A) HZ42STE: See Thru B) HZ42STE: See Thru

5) This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6) The HZ42STE Direct Vent Gas Fireplace is approved for alcove installations, which meet the clearances listed on this page.

7) We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualified inspector, dealer, or installer review your plans before installation.

Note: For Exterior Vent Termination Locations see section "Exterior Vent

Termination Locations."

Glass36" min.(914mm)

36" min.(914mm)

Glass

A

B

36"min.(914mm)

36"min.(914mm)

36"min. walkway (914mm)

Glass Glass

HZ42 ST - SEE THRU

HZ42 ST - SEE THRU

See mantel clearances

Page 10: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

10 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 10 installation

Caution RequirementsThe top, back and sides of the fireplace are defined by

standoffs. The metal ends of the standoff may NOT be recessed into combustible construction.

WARNINGFire hazard is an extreme risk

if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent

system be installed only in accordance with these instructions.

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.

F

B

C

Installed Closeto Ceiling

Flue Clearances to CombustiblesHorizontal - Top 3"Horiztonal - Side 2"Horiztonal - Bottom 2"Vertical 2"

Passing through wall/f loor/cei l ing - when firestop is used.

1-1/2"

F

B

E

D

A

Installed Closeto Floor

G

Clearance: Dimension Measured From:A: Mantel Height (min.) 17" (432mm) Top of Fireplace Opening

B: Sidewall (on one side) 7" (178mm) if Horizontal Venting 9" (229mm) if Vertical Venting

Side of Fireplace Opening

C: Ceiling (room and/or alcove)

22" (559mm) Top of Fireplace Opening

D: Mantel Depth (max.) 12" (305mm) 21-1/2" Above Fireplace Opening

E: Alcove Width 84" (2134mm) Sidewall to Sidewall (Minimum)

F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum)G: Finished Floor 25-1/4" (641mm) Top of Fireplace OpeningNote 0" (0mm) No Hearth Required

Page 11: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 11

11| installationFRAMING DIMENSIONS

HZ42STE Framing Dimensions

A * Framing Depth * 20" (508mm)**minus 2X the finished material thickness

B Framing Height 42" (1067mm)

C Framing Width 54" (1372mm) Horizontal /58" (1473mm) Vertical Vent

D Gas Connection Height 3-7/16" (87mm)

E Gas Connection Inset 4-7/8" (124mm)

F Gas Connection Opening Width 3-1/2" (89mm)

G Gas Connection Opening Height 2-5/8" (67mm)

H Minimum Height to Combustibles 42" (1067mm)

* Framing depth measurement is noted with nailing strips (top & sides) set as far forward on the firebox as possible. The nailing strips can be adjusted (on both sides) to allow for varying thicknesses in non-combustible material and wall finishes.

**Finished material thickness includes: non combustible material, tile slate, etc. (example framing = 20" - if 2" thick finishing material is used (on both sides)=16"

Note: Gas hookup is on vent side of unit.

CL

CL

3" (

mm

)6

914

Min

. he

ight

(Fle

x or

Rig

id)

centerof hole

IMPORTANT: 1/2" gap required between faceplate and finished wall.Dangerous operating conditions will occur if this is not adhered to.

B

C

A

FinishedFloor

H

Steel studson edge

41" (1041mm)

8-1/2"(216mm)

25-1/2""(648mm)

33"(838mm)

C

B

Steel studs - for ease of installation of non combustible ma-terial-after Part I is complete.* Install after unit in place with gas connection, electrical and venting completed.

Part I Part II

Steel studs

Important:Determine the wall thickness prior to framing this unit. The finished wall depending on thickness would decrease the required clearance of 7 or 9 inches depending if this is horizontally vented/Vertically vented so thought must be put into the framing details.If the finished wall is 1/2 inch–the framing should be 1/2 inch deeper to accommodate the finished wall.

Unit

Finished wall

Page 12: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

12 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 12 installationNON-COMBUSTIBLE FACING INSTALLATION

Non-combustible boardshipped with unit.

Non-combustible board-faces and edgesMUST BE PRIMED.

Non-combustible boardshipped with unit.

Bottom not supplied-can be combustible material(ie:drywall)

IMPORTANTRegency Fireplace Products are designed, produced, tested and certified to the highest industry standards. The finishing of the walls surrounding your Regency Horizon Fireplace is as critical as the installation itself. The temperatures around linear gas fireplaces are typically higher than would be acceptable for combustible materials. Your Regency Horizon Fireplace is no exception to this rule. Therefore, the units are specified with non-combustible required materials to specific dimensions above and around the units. This is due to these areas reaching higher temperature levels than required/acceptable for a combustible material. To obtain the best, most durable finish around your fireplace, this calls for a high level of care and attention to the preparation and finish around this appliance, using only the highest quality materials, able to withstand the temperatures produced.By following the installation instructions in the manual exactly, you will increase your chances of a damage free finish.While every precaution is taken in providing the recommendations on preparation and finish, given the variations in paint quality, with temperature limits and workmanship in application, Regency is unable to guarantee the life of the joint compounds, paint or any other finish materials or workmanship applied to or used in any application surrounding the fireplace. This includes framing as well as finishing.Over time natural convection from any fireplace can cause discoloration in the area directly above the appliance. Lower quality paints, under-prepared finishes, poor applications, and any framing discrepancies or in the installation can cause this discoloration process to be expedited.Discoloration is not the responsibility of Regency Fireplace Products. This is outwith the control of Regency Fireplace Products Ltd., therefore not covered under any part of the warranty policy.While discoloration is not the responsibility of Regency Fireplace Products, we believe careful attention to the recommendations provided here will result in an aesthetically pleasing result free of issues outlined above.

Caution: The non-combustible board (order part #588-936) can be damaged if dropped or struck. Handle with care.

1) Using drywall screws - secure non combustible material around unit, framing and top nailing strip every 6 inches.

Important Note: To avoid cracking the board - pre-drill holes prior to securing to unit/ framing.

2) Wipe any debris/dust from the non combustible material and drywall.

3) Prior to securing it is mandatory to prime the facing and edges using a quality primer. This will ensure proper adhesion of both the tape and mud. The supplied board is very porous.

Failure to follow this procedure will result in cracked seams.

4) Tape the seams using a mesh type tape.

5) Mud seams as normal. We recommend using a product called Durabond high strength compound - for the first coat. This product can be found at any hardware store. Mud must be cured as per manufacturer’s recommendations.

6) Prime wall for a second time for proper adhesion of paint

7) Paint walls using a high quality paint which will withstand the high temperatures being emitted from this appliance.

Page 13: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 13

13| installation

NON-COMBUSTIBLE REQUIREMENTSDetermine whether the venting will be a horizontal or vertical as the non combustible material can be cut to size dependant on whether unit is horizontally/vertically vented. The non combustible material comes in 3 separate pieces, top section is 57-3/4"x 9" - side sections are 9" x 17".

57-3/4"

17"

39-3/4"

17"

9" 9"

8"

42"

Non-combustible material (supplied)

Combustible material (not supplied) ie. Drywall

VERTICAL VENTING

HORIZONTAL VENTING

Page 14: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

14 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 14 installationMANTEL CLEARANCES

Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.

MANTEL LEG CLEARANCESCombustible mantel leg clearances as per diagram:

Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

279

356

356

279

Finished Wall

Finished Wall

Horizontal venting clearance requirements are shown.

If Vertically venting add 2” due to the adapter and venting pushing the unit away from the wall Clearance to 1-1/2” mantel leg mantel increases to 9”Clearance to 4” mantel leg increases to 13” Clearance to a 7” mantel leg increases to 16 inches

ImportantDetermine the wall thickness prior to framing this unit. The finished wall depending on thickness would decrease the required clearance of 7 or 9 inches depend-ing if this is horizontally vented/Vertically vented so thought must be put into the framing details.If the finished wall is 1/2 inch the framing should be 1/2 inch deeper to accommodate the finished wall

2

0

12 6 4810

Top ofFireplaceOpening

0

14

To UnitBase

22�

1 �7

25- /4�1

10

20

26

Combustible Material2

0

12 6 4810

Top ofFireplaceOpening

Standoff

Metal Stud(On Edge)

0

14

Non-combustibleFacing

1" (25mm)

10

20

26

20

1264 8 10

Top ofFireplaceOpening

12" (305mm)

0

14

To UnitBase

1" (25mm)

21-1/2�

1 �7

25- /4�1

10

20

26

12" (305mm)

21-1/2�

Page 15: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 15

15| installation

Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.

2) The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clear-ances" section. Combustible materials can be laid against the side and back standoffs and the stove base.

3) Non-combustible material (ie. tile, slate, etc) may be brought up to and overlap the unit (top and bottom) ensuring that the maximum thickness does not go beyond the 3" as shown in the diagram below. The faceplate will not be able to be mounted if the finished material is beyond 3".

FRAMING & FINISHING

1) Frame in the enclosure for the unit with framing material.

IMPORTANT: Vertical studs and the header must be metal.

Note:

Depending on the material used for finishing, the nailing strips must be set accordingly so that the finished material is always at the 3" edge of the flange.

4) If material such as brick, stone, etc. extends past the faceplate depth, when finishing around the faceplate, the minimum opening dimensions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance.

FinishedMaterial

Nailing StripPosition

1/2" 2-1/2"

1" 2"

1-1/2" 1-1/2"

Unit

Nailing Strip1� Forward

Unit

Nailing Strip½� Forward

Unit

Nailing StripFlush w/unitFactory Set

Unit shown with 4 piece faceplate/Verona Glass Surround

2-

/8"

27

46�

Unit shown with inner and outer door frame

Unit shown with inner door frame only

39-13/16”

16-7

/8”

Page 16: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

16 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 16 installation

UNIT ASSEMBLY PRIOR TO INSTALLATIONThe Standoffs and Nailing Strips must be correctly positioned and attached to the firebox before unit is slid into position.

STANDOFF ASSEMBLY

The side, top and rear standoffs are shipped in a flat position and must be folded into shape and attached.

1) Remove the standoffs from the fireplace.

2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre-punched screw holes on the fireplace side line up.

3) Attach the standoff securely to the side with 2 screws per standoff (on opposite corners).

INSTALLATION ACCESS PANELThe unit is equipped with a removable access panel for pre-finish installation of optional components - this panel is located on the lower front face.

1. Remove 8 screws to remove access panel.

2. Easier access to gas connection with panel removed.

3. Install any optional components with access panel removed.

4. Reinstall access panel with 8 screws - prior to installing any facing material

Note: Access panel is no longer usable once facing material installed.

Installation Access Panel

Page 17: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 17

17| installationOPTIONAL FRAMING KIT

919-505 02.13.151

HZ42STE

58"- Vertical Vent54"- Horizontal Vent

42"

Horizontal Exit Vent Installation Only:Use inner holes on top horizon-tal studs–cut off excess from each end before securing frame to the wall

Cut here

An optional framing kit is available for the HZ42STE.

Note: There are different confi gurations for horizontal exit venting vs vertical exit venting and options in the framing width to accommodate various thick-nesses of fi nishing materials. Determine your installation prior to assembly of this frame kit.

Prior to assembling the framing kit, determine the overall thickness of the non combustible material plus fi nishing material. Framing must be 20 inches minus the overall non combustible/fi nishing material. Example= 2 inches of fi nishing material per side = 16 inches framing width.

1. Assemble the 2 (two) vertical ends (V) of the framing kit by securing hori-zontal studs (H) with 4 (four) screws securing each stud–two on each side.

The horizontal studs (H) are adjustable in 1/2" increments to accommodate fi nishing materials - determine the thickness of the fi nishing materials before securing the horizontal studs (H)..

3. If installing the unit with horizontal venting–secure the 2 (two) top horizontal studs using the inner holes–cut the remainder of the stud (repeat at other end) before proceeding to Step 3.

OPTIONAL FRAMING KIT2 Install the 2 long horizontal studs, secure with 2 screws on each end - if

installing with horizontal vent exit see Step 4 before installing.

4. Install 2 top horizontal studs with 2 screws on each side.

VV

H

H

VV

H

H

H

Cross Center Horizontal studs are adjustable in

1/2" increments.

Vertical Side

20" minus 2Xfi nishing material

Vertical Exit Vent Install–use these holes (onboth sides)

58"- Vertical Vent54"- Horizontal Vent

42"

Horizontal Studs

H

Page 18: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

18 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 18 installation

919-505 02.13.152

HZ42STE

6. Set unit in place, center within framing from each side and also back to front–install 2 (two) wide studs above and below the unit as shown with 2 (two) screws on each side - repeat on opposite side.

7. Install 2(two) thin vertical studs on either side of the unit as shown with 2(two)screws on each end.

Side Supports Thin Vertical Studs

Stud

8. Install 1 stud in the location shown below with 2(two) screws on each side.

9. Proceed with the installation of non-combustible and fi nishing materials.

Wide Studs

5. Install the 2 long horizontal studs, secure with 2 screws on each end - if installing with horizontal vent exit see Step 4 before installing.

Cut off excess on horizontal wide studs for Horizontal

Exit Installations

Top

Bottom

Top

Bottom

Page 19: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 19

19| installationHORIZONTAL VENT DEFLECTOR INSTALLATIONNote: This installation is only required for horizontal terminations. If any

rise is used when venting this unit - the deflector and extender are not required.

1) The deflector and extender are shipped on top of the firebox. Slide the deflector out from under the nailing strip and lift the extender up off the nailing strip.

2) Remove the 3 screws near the vent outlet on the firebox - as shown below.

3) Install the deflector near the vent outlet - secure with the same 3 screws. Ensure flange on deflector is facing downward.

4) Install the extender on top of the deflector with 2 screws - slide the extender until it touches the outside wall - tighten screws to secure. Extender can be adjusted to max. 15-1/2".

Deflector extenderDeflector

Flange

Page 20: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

20 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 20 installation

J-BoxReceiver

Wall Plate

Slider Switch

Low Voltage Junction Box

Diagram 1

10 ft. wire harness with 12 pin connector

IMPORTANT INSTALLATION NOTE:

The Receiver must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only.

DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.

Remote Receiver Installation

1. Install the low voltage junction box to the framing, at desired location within 10 ft. from fi replace.2. Feed the 12 pin connector through the opening at back of junction box. 3. Connect the 12 pin connector to the back of the receiver.4. Install the Receiver in the Low Voltage Junction box.5. Insert the 4 AA type batteries in the battery compartment with the correct polarity.6. Place the slider into the cover plate.7. Put the Receiver switch in the “OFF” position, to allow correct lineup for slider switch.8. Make sure the Receiver and cover plate words “ON” and “UP” are on the same side.9. Align the slider with the switch on the Receiver and couple the switch into the slider.10. Align the screw holes.11. Using the two (2) screws provided secure the cover plate to the Receiver.

Profl ame Receiver

WALL MOUNT ON / OFF SWITCH AND REMOTE RECEIVER INSTALLATIONREQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS

Page 21: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 21

21| installation

Vent restriction is required for certain venting installations, see the diagrams in the "VentingArrangements" section to determine if they are required for your installation.

The Vent Restrictor plate is located on the inside top of the firebox.

To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;

1) Remove the glass door.

2) Remove the screws that hold the vent restrictor plate in place.

3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.

4) Once the vent restrictor plate is in the required position, secure with screws.

VENT RESTRICTOR POSITION

3/4� 1-1/4� 2-1/2� 3�

SET 0

FACTORY SET

THIS HOLE SETS THEVENT RESTRICTOR

AT 3�

SET 1THIS HOLE SETS THEVENT RESTRICTOR

AT 2-1/2�

SET 2THIS HOLE SETS THEVENT RESTRICTOR

AT 1-1/4�

SET 3THIS HOLE SETS THEVENT RESTRICTOR

AT 3/4�

Page 22: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

22 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 22 installation

EXTERIOR VENT TERMINATION REQUIREMENTS

Minimum Clearance Requirements Canada1 USA2

A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm)

B Clearance to window or door that may be opened 12"(30cm) 9" (23cm)

C Clearance to permanently closed window * *

D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal (check with the local code)

18"(46cm) 18"(46cm)

E Clearance to unventilated soffit 19"(48cm) 19"(48cm)

F Clearance to outside corner: with AstroCap Termination Cap. 7"(18cm) 7"(18cm)

Clearance to outside corner: with all other approved Termination Caps. 13"(33cm) 13"(33cm)

G Clearance to inside corner: with AstroCap Termination Cap 7"(18cm) 7"(18cm)

Clearance to inside corner: with all other approved Termination Caps. 13"(33cm) 13"(33cm)

H Clearance to each side of center line extended above meter/regulator assembly 36"(90cm)a *

J Clearance to service regulator vent outlet 36"(90cm) *

K Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(30cm) 9" (23cm)

L Clearance to a mechanical air supply inlet #3' (91cm) above if within 10' (3m) horizontally. 72"(1.8m) 36"(90cm)b

M Clearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)┼ *

N Clearance under veranda, porch, deck, or balcony 12"(30cm)‡ *

1 In accordance with current CSA B149.1, Natural Gas and Propane Installation Code2 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code┼ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor

* Clearance in accordance with local installation codes and the requirements of the gas suppliera 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assemblyb 3 feet (91cm) above - if within 10 feet (3m) horizontally

Page 23: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 23

23| installation

4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

Description SimpsonDirect Vent Pro®

SelkirkDirect Temp™

American MetalProducts®

Amerivent Direct

Metal-Fab™Sure Seal

SecuritySecure- Vent®

ICC Excel Direct

6” Pipe Length-Galvanized 46DVA-06 4DT-6 N/A 4D6 SV4L6 TC-4DL6

6” Pipe Length-Black 46DVA-06B 4DT-6B N/A 4D6B SV4LB6 TC-4DL6B

7” Pipe Length-Galvanized N/A N/A 4D7 N/A N/A N/A

7” Pipe Length-Black N/A N/A 4D7B N/A N/A N/A

9” Pipe Length-Galvanized 46DVA-09 4DT-9 N/A N/A N/A TC-4DL9

9” Pipe Length-Black 46DVA-09B 4DT-9B N/A N/A N/A TC-4DL9B

12” Pipe Length-Galvanized 46DVA-12 4DT-12 4D12 4D12 SV4L12 TC-4DL1

12” Pipe Length-Black 46DVA-12B 4DT-12B 4D12B 4D12B SV4LB12 TC-4DL1B

18” Pipe Length-Galvanized 46DVA-18 4DT-18 4D18 4D18 SV4LA TC-4DL18

18” Pipe Length-Black 46DVA-18B 4DT-18B 4D18B 4D18B SV4LA TC-4DL18B

24” Pipe Length-Galvanized 46DVA-24 4DT-24 4D24 4D24 SV4L24 TC-4DL2

24” Pipe Length-Black 46DVA-24B 4DT-24B 4D24B 4D24B SV4LB24 TC-4DL2B

36” Pipe Length-Galvanized 46DVA-36 4DT-36 4D36 4D36 SV4L36 TC-4DL3

36” Pipe Length-Black 46DVA-36B 4DT-36B 4D36B 4D36B SV4LB36 TC-4DL3B

48” Pipe Length-Galvanized 46DVA-48 4DT-48 4D48 4D48 SV4L48 TC-4DL4

48” Pipe Length-Black 46DVA-48B 4DT-48B 4D48B 4D48B SV4LB48 TC-4DL4B

60” Pipe Length-Galvanized 46DVA-60 4DT-60 N/A N/A N/A N/A

60” Pipe Length-Black 46DVA-60B 4DT-60B N/A N/A N/A N/A

Adjustable Length 3”-10”-Galvanized N/A N/A N/A 4DAL N/A TC-4DLT

Adjustable Length 3”-10”-Black N/A N/A N/A 4DALB N/A TC-4DLTB

Adjustable Length 7”-Galvanized N/A N/A 4D7A N/A N/A N/A

Adjustable Length 7”-Black N/A N/A 4D7AB N/A N/A N/A

Extension Pipe 8-1/2”-Galvanized 46DVA-08A N/A N/A N/A N/A N/A

Extension Pipe 8-1/2”-Black 46DVA-08AB N/A N/A N/A N/A N/A

Adjustable Length 12”-Galvanized N/A N/A 4D12A N/A SV4LA12 TC-4dLSI

Adjustable Length 12”-Black N/A N/A 4D12A N/A SV4LBA12 TC-4dLSIB

Extension Pipe 16”-Galvanized 46DVA-16A N/A N/A N/A N/A N/A

Extension Pipe 16”-Black 46DVA-16AB N/A N/A N/A N/A N/A

45º Elbow-Galvanized 46DVA-E45 4DT-EL45 4D45L N/A N/A TE-4DE45

45º Elbow-Black 46DVA-E45B 4DT-EL45B 4DT-EL45B N/A N/A TE-4DE45B

45º Elbow Swivel-Galvanized See 46DVA-E45 N/A N/A 4D45L SV4E45 N/A

45º Elbow Swivel-Black See 46DVA-E45B N/A N/A 4D45LB SV4EB45 N/A

90º Elbow-Galvanized 46DVA-E90 4DT-EL90S 4DT-EL90S N/A N/A TE-4DE90

90º Elbow-Black 46DVA-E90B 4DT-EL90SB 4DT-EL90SB N/A SV4EBR90-1 TE-4DE90B

90º Elbow, Swivel-Galvanized See 46DVA-E90 N/A N/A 4D90L SV4E90-1 N/A

90º Elbow, Swivel-Black See 46DVA-E90B N/A N/A 4D90LB SV4EB90-1 N/A

90º Starter Elbow, Swivel-Galvanized N/A N/A N/A 4D90A N/A N/A

Adaptor* N/A N/A N/A 4D90L N/A N/A

4” X 6- 5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency.

Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.

Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com

Ceiling Support N/A 4DT-CS 4DSP 4DFSP SV4SD TM4-RDS

Cathedral Support Box 46DVA-CS 4DT-CSS 4DRSB 4DRS SV4CSB TM4-SDS

Wall Support/Band 46DVA-WS 4DT-WS/B 4DWS 4DWS SV4BM TM-SWS

Offset Support 46DVA-ES - N/A from FPI 4DT-OS N/A N/A SV4SU TM-SOS

Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM N/A

Wall Thimble Support/Ceiling Support 46DVA-DC N/A N/A N/A SV4PF N/A

Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS

Trim Plate-Black N/A 4DT-TP 4DFPB 4DcP SV4LA TM-4TP

Page 24: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

24 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 24 installation

Description SimpsonDirect Vent Pro®

SelkirkDirect Temp™

American MetalProducts®

Amerivent Direct

Metal-Fab™Sure Seal

SecuritySecure- Vent®

ICC Excel Direct

Attic Insulation Shield 12” 46DVA-IS N/A@ FPI N/A 4DAIS12 N/A SV4RSA N/A

Attic Insulation Shield - Cold Climates 36” N/A N/A 4DAIS12 N/A N/A TM-4AS

High Wind Vertical Cap 46DVA-VCH N/A N/A N/A N/A TM-4VT

High Wind Horizontal Cap 46DVA-HC N/A N/A N/A N/A TM-4DHT

Horizontal Square Termination Cap See 46DVA-HC 4DT-HHC 4DHC 4DHT SV4CHC-1 TM-4HT

Vertical Termination Cap 46DVA-VC 4DT-HVC 4DVC 4DVT SV4CGV-1 N/A

Storm Collar 46DVA-08A 4DT-SC 4DSC 4DSC SV4FC TM-SC

Restrictor Disk N/A N/A N/A N/A N/A TM-4DS

Extended Vertical Termination Cap N/A N/A N/A N/A N/A N/A

Chimney Conversion Kit A (USA only) 46DVA-KCA N/A N/A N/A N/A TM-4CA6

Chimney Conversion Kit B (USA only) 46DVA-KCB N/A N/A N/A N/A TM-4CA7

Chimney Conversion Kit C (USA only) 46DVA-KCC N/A N/A N/A N/A TM-4CA8

Chimney Conversion Kit Masonry (USA only)

46DVA-KMC N/A N/A N/A N/A N/A

Wall Firestop 46DVA-WFS N/A N/A N/A N/A TM-4TR

Colinear Flex Connectors 46DVA-ADF N/A N/A N/A N/A N/A

Adjustable Flashing 0/12-6/12 46DVA-F6 4DT-ST14 4D12S 4DST14 SV4STC14 TF-4FA

Adjustable Flashing 6/12-12/12 46DVA-FLA 4DT-ST36 4D36S 4DST36 SV4STC36 TF-4FB

Vinyl Siding Standoff 46DVA-VSS 4DT-VS N/A 4DVS SV4VS TM-VSS

Vinyl Siding Shield Plate N/A 4DT-VSP N/A N/A SV4VS N/A

Snorkel Termination 14” 46DVA-SNKL N/A N/A N/A N/A TM-4ST14

Snorkel Termination 36” N/A N/A N/A N/A N/A TM-4ST36

Basic Horizontal Termination Kit (A) Disc. 4DT-HKA 4DHTK2 4DHTKA SV-SHK TM4-HTK

Horizontal Termination Kit (B) 46DVA-KHA(Changed Components)

4DT-HKB 4DHTK1 4DHTKB SV-HK TM4-HTK

Vertical Termination Kit Disc. 4DT-VKC 4DHTK 4DHTK SV-FK N/A

FPI

946-506/P Vent Guard (Optional) for AstroCap 946-205 Vinyl Siding Shield for Riser Vent Terminal

510-994 Rigid Pipe Adaptor (Must use with all rigid piping) 946-208/P Vent Guard (Optional) for Riser Vent Terminal

640-530/P Riser Vent Terminal 946-523/P AstroCap Horizontal Cap

946-605 Starter Collar Increaser 4” x 6-5/8” to 5” x 8” 946-206 Vinyl Siding Standoff for AstroCap

Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.

Offset Pipe Selection: Use this table to determine offset pipe lengths.

Pipe Length(L)

4” x 6-5/8” Venting For specifi c instructions on venting components - visit the manufacturers website listed below.

Run (X) Rise (Y)

0” (0mm) 4-7/8” (124mm) 13-7/8” (340mm) Simpson Direct Vent Pro: www.duravent.com

6” (152mm) 8” (203mm) 16-1/2” (419mm) Selkirk Direct-Temp: www.selkirkcorp.com

9” (229mm) 10-1/8” (257mm) 18-5/8” (473mm) American Metal Products: www.americanmetalproducts.com

12” (305mm) 12-1/4” (311mm) 20-3/4” (527mm) Metal-Fab Sure Seal: www.mtlfab.com

24” (610mm) 20-5/8” (524mm) 29-1/8” (740mm) Security Secure Vent: www.securitychimneys.com

36” (914mm) 29” (737mm) 37-1/2” (953mm) Industrial Chimney Company: www.icc-rsf.com

48” (1219mm) 37-7/16” (951mm) 45-15/16” (1167mm)

Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com

Page 25: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 25

25| installation

VENTING INTRODUCTIONThe HZ42STE uses the "balanced flue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be connected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

VENTING ARRANGEMENTS

ALLOWABLE HORIZONTAL TERMINATIONS FOR HZ42 ST

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45º and one 90º (two 45o elbows equal to one 90o ) for direct horizontal runs with horizontal termination use only one 45º elbow.Note: Must use optional rigid pipe adapter (Part# 510-994) when using Rigid Pipe Venting Systems.

VENT RESTRICTOR SETTING:Vent restrictor factory set, no adjustment required unless otherwise indicated.Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set 2 if required.

Note: Regency® Direct Vent System (Flex) is only approved for horizontal terminations.

• Maintain clearances to combustibles as listed in "Clearances" section• Horizontal vent must be supported every 3 feet.• Firestops are required at each floor level and whenever passing through a wall.• A wall thimble is mandatory for all horizontal terminations due to high temperatures.• Flex system can only be used up to 10 feet - otherwise rigid venting must be used.

20 12 206 14

3 � ( mm)6 914Minimum Height

Requirement

4 8 1610 18

Verti

cal H

eigh

t (Fe

et)

Horizontal (Feet)

2

0

12

6

4

14

8

10

16

18

SET 2

SET 1 SET 0(factory setting)

Please note the minimum centerline for basic install shown above.

CL

CL

3" (

mm

)6

914

Min

. he

ight

(Fle

x or

Rig

id)

centerof hole

Page 26: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

26 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 26 installation

Notes:

1) Liner sections should be continuous without any joints or seams.

2) Only Flex pipe purchased from Regency® may be used for Flex installations

3) Horizontal vent must be supported every 3 feet.

4) Regency® Direct Vent System (Flex) is only approved for horizontal terminations.

5) Flex system can only be used up to a maximum continuous vent length of up to 10 feet. If longer runs are required, rigid pipe must be used.

FPI Kit # Length Contains:#946-513 2 Feet 1) 6-5/8” flexible outer liner (Kit length)

2) 4” flexible inner liner (Kit length)3) spring spacers4) thimble 5) AstroCap termination cap 6) screws 7) tube of Mill Pac 8) plated screws 9) S.S. screws #8 x 1-1/2” drill point

#946-515 4 Feet

#946-516 10 Feet

HORIZONTAL TERMINATIONSFLEX VENT 4" X 6-5/8"

These venting systems, in combination with the HZ42STE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section.

Regency® Direct Vent (Flex) System Termination Kits includes all the parts needed to install the HZ42 using a flexible vent.

Page 27: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 27

27| installation

Pipe Length

PipeLength

90 Elbowo

HorizontalTermination Cap

Wall Thimble

Vinyl SidingStandoff (Optional)

Rigid Pipe Adapter

45 Elbowo

RIGID/FLEX PIPE VENTING SYSTEMSHorizontal or Vertical TerminationsThe minimum components required for a basic horizontal termination are:

1 Simpson Duravent Adaptor 1 Horizontal Termination Cap 1 45o Elbow 1 Rigid Pipe Adaptor 1 Wall Thimble 1 Length of pipe to suit wall thickness (see chart)

Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.

When using Rigid Vent other thanSimpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent , Selkirk Direct-Temp, Ameri Vent Direct, ICC Excel, MetaFab venting and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCapTM and FPI Riser is acceptable with all systems.

The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent, American Metal Products Ameri Vent Direct Vent, ICC Excel, MetaFab, Security Secure Vent®, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Flat Wall Installation

Wall Thickness(inches)

Vent Length Required(inches)

4" - 5-1/2" 6"

7" - 8-1/2" 9"

10" - 11-1/2" 12"

9" - 14-1/2' 11" - 14-5/8" Adj. Pipe

15" - 23-1/2" 17" - 24" Adj. Pipe

Page 28: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

28 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 28 installation

Horizontal Venting with Two (2) 90o Elbows Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V H + H1 With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

A) 1' Min. 3' Max.B) 2' Min. 4' Max.C) 3' Min. 5' Max.D) 4' Min. 6' Max.E) 5' Min. 7' Max.F) 6' Min. 8' Max.

One 90o elbow = Two 45o elbows.

Option H V H + H1 + H2 With these options, maximum total pipe length is 30 feet with minimum of 11 feet total vertical and maximum 9 feet total horizontal.

P l e a s e n o t e minimum 1 foot between 90o elbows is required.

A) 1' Max. 1' Min. 3' Max.B) 2' Max. 3' Min. 5' Max.C) 3' Max. 5' Min. 6' Max.D) 4' Max. 7' Min. 7' Max.E) 5' Max. 9' Min. 8' Max.F) 6' Max. 11' Min. 9' Max.

Restrictor Position - Set 0 (factory setting) Restrictor Position - Set 0 (factory setting)

HORIZONTAL TERMINATIONSRIGID PIPE 4" X 6-5/8"

The diagrams below shows examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow)

1) A maximum of three 90o elbows are permitted (not including the starting 45o elbow at the flue collar when using rigid venting).

2) Minimum distance between elbows is 1 ft. (305mm).

• Maintain clearances to combustibles as listed in the "Clearances" section.• Horizontal vent must be supported every 3 feet.• Firestops are required at each floor level and whenever passing through a wall.• Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.• A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.• Flex system can only be used up to 10 feet - otherwise rigid venting must be used.

Page 29: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 29

29| installation

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V H V + V1 H + H1 With these options, maximum total pipe length is 30 feet with minimum of 12 feet total vert ical and maximum 9 feet total horizontal.

P l e a s e n o t e minimum 1 foot between 90o elbows is required.

A) 2' Min. 1' Max. 3' Min. 4' Max.B) 3' Min. 2' Max. 4' Min. 5' Max.C) 4' Min. 3' Max. 6' Min. 6' Max.D) 5' Min. 4' Max. 8' Min. 7' Max.E) 6' Min. 5' Max. 10' Min. 8' Max.F) 7' Min. 6' Max. 12' Min. 9' Max.

Restrictor Position - Set 0 (factory setting)

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option H V H + H1 With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 8 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

A) 1' Max. 1' Min. 3' Max.B) 2' Max. 2' Min. 5' Max.C) 3' Max. 4' Min. 6' Max.D) 4' Max. 6' Min. 7' Max.E) 5' Max. 8' Min. 8' Max.

Restrictor Position - Set 0 (factory setting)

Page 30: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

30 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 30 installation

• Vent must be supported at offsets.• Firestops are required at each floor level and

whenever passing through a wall.• Maintain clearances to combustibles as listed in

the "Clearances" section.• Refer to the "Vent Restrictor Position" section for

details on how to change the vent restrictor from Set 0 (factory setting) to Set 1 to Set 2 or Set 3 if required.

Note: Must use optional flue adaptor when using Rigid Pipe (Part # 510-994).

VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90o elbows, with Rigid

Pipe Venting Systems for Natural Gas. Two 45o elbows equal to one 90o elbow. Maximum of two 45o elbows allowed,not including the starting 45o off the collar.

Please note: min. 1 foot horizontal required before 90o elbow.(No back to back elbows.)

Max

imum

: 38

ft. (1

1.6m

)

Min

imum

7�(2

.1m

)

Min

. 3�6

(m

m)

914

Minimum length of pipebetween elbows 12� (305mm)

Max

imum

: 27

ft. (8

.2m

)

0

2

4

6

40

8

10

12

14

16

18

20

22

24

26

28

30

Verti

cal H

eigh

t (Fe

et)

32

34

36

38

6 8

Horizontal (Feet)

20 4 10 12

Vent Restrictor on Set 2

Vent Restrictor on Set 1

Vent Restrictoron Set 3

Page 31: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 31

31| installation

VERTICAL TERMINATIONSRIGID PIPE 4" X 6-5/8"

The minimum components required for a basic vertical termination are:

1 Vertical Termination Cap 1 45o Elbow 1 Rigid Pipe Adaptor (510-994) 1 Ceiling Firestop 1 Flashing 1 Storm Collar 1 Length of pipe to suit wall thickness (see chart)

When using Rigid Vent other thanSimpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent, Selkirk Direct-Temp, Ameri Vent Direct Venting, ICC Excel Direct and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCapTM and FPI Riser is acceptable with all systems.

The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent, American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, ICC Excel, Selkirk Direct-Temp. AstroCapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Roof Pitch Minimum Vent Height Feet Metersflat to 7/12 2 0.61over 7/12 to 8/12 2 0.61over 8/12 to 9/12 2 0.61over 9/12 to 10/12 2.5 0.76over 10/12 to 11/12 3.25 0.99over 11/12 to 12/12 4 1.22over 12/12 to 14/12 5 1.52over 14/12 to 16/12 6 1.83over 16/12 to 18/12 7 2.13over 18/12 to 20/12 7.5 2.29over 20/12 to 21/12 8 2.44

Galvanized pipe is desirable above the roofline due to its higher corrosion resistance. Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Dia. 4 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.

Vertical Terminal

Storm Collar

Flashing

Ceiling Firestop

PipeLength

Rigid Pipe Adapter

45 Elbowo

Page 32: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

32 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 32 installation

Vertical Venting with Two (2) 90o Elbows

Vertical Venting with Two (2) 90o Elbows

For additional vertical venting with 2 x 90o elbows, refer to "Rigid Pipe Venting Arrangements" Section.

One 90o elbow = Two 45o elbows.

Option V H V + V1 With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

A) 1' Min. 4' Max. 2' Min.B) 2' Min. 5' Max. 3' Min.C) 3' Min. 6' Max. 4' Min.D) 4' Min. 7' Max. 5' Min.E) 5' Min. 8' Max. 6' Min.

One 90o elbow = Two 45o elbows.

Option H + H1 V With these options, maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 6 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

A) 2' Max. 2' Min.B) 3' Max. 3' Min.C) 4' Max. 4' Min.D) 5' Max. 5' Min.E) 6' Max. 6' Min.

Restrictor Position - Set 0 (factory setting)

Restrictor Position - Set 0 (factory setting)

VERTICAL TERMINATIONSRIGID PIPE 4" X 6-5/8"

• Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed, not including the starting 45o elbow at the flue collar. • Vent must be supported at offsets.• Minimum distance between elbows is 1 ft. (305mm).• Maintain clearances to combustibles as listed in the "Clearances" section.• Horizontal vent must be supported every 3 feet.• Firestops are required at each floor level and whenever passing through a wall.• Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.

Page 33: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 33

33| installation

Vertical Venting with Three (3) 90o Elbows

Vertical Venting with Three (3) 90o Elbows

Option H V H + H1 V + V1 A) 1' Max. 1' Min. 3' Max. 3' Min. B) 2' Max. 2' Min. 4' Max. 5' Min. C) 3' Max. 3' Min.' 5' Max. 7' Min. D) 4' Max. 4' Min. 6' Max. 9' Min. E) 5' Max. 5' Min. 7' Max. 11' Min.

One 90o elbow = Two 45o elbows.

One 90o elbow = Two 45o elbows.

With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 7 feet total horizontal.Please note min. 1 foot between 90o elbows is required.

Option V H + H1 V + V1 A) 2' Min. 3' Max. 4' Min. B) 3' Min. 4' Max. 6' Min. C) 4' Min. 5' Max. 7' Min. D) 5' Min. 6' Max. 8' Min. E) 6' Min. 7' Max. 9' Min. F) 7' Min. 8' Max. 10' Min.

With these options, max. total pipe length is 30 feet with min. of 10 feet total vertical and max. 8 feet total horizontal.Please note min. 1 foot between 90o elbows is required.

Restrictor Position - Set 0 (factory setting)

Restrictor Position - Set 0 (factory setting)

Page 34: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

34 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 34 installation

Diagram 4

Diagram 3

7) Ensure that the pipe clearances to combustible materials are maintained (Diagram 5). Install the termination cap.

Note: If installing termination on a vinyl siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding.

The four wood screws provided should be re-placed with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

8) Before connecting the horizontal run of vent pipe to the vent termination, slide the Wall Thimble over the vent pipe. The wall thimble is required for all horizontal terminations.

9) Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap.

10) Install wall thimble in the center of the framed hole and attach with wood screws (Diagram 7).

Install the vent system according to the manufacturer's instructions included with the components.

1) Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left.

2) Direct Vent pipe and fittings are designed with special twist-lock connections to connect the venting system to the appliance flue outlet. A twist-lock appliance adaptor is required.

3) In conjunction with the Approved Vent system, install the adaptor after the unit is set in its desired location. Put a bead of Mill-Pac inside the outer section of the adapter and on the inner collar. Slip the adapter over the existing inner and outer flue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier).

4) Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips.

Diagram 1

Note: For best results and optimum performance with each approved venting system, i t is highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty. Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose.

Diagram 2

6) Mark the wall for a square hole.-see chart to left for size. The center of the square hole should line up with the center-line of the horizontal pipe. Cut and frame the square hole in the exterior wall where the vent will be terminated. See diagram 2 for center line requirements.

If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable.

Note: a) The horizontal run of vent must be level,

or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.

b) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations" section for more details.

5) Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection.

Recommended Framed Opening Size

Vent Size Framing Size

4" x 6 - 5/8" 10" x 10"

Horizontal Top* 3" (76mm)*

Horizontal Side 2 " (51mm)

Horizontal Bottom 2" (51mm)

Vertical Vent 2" (51mm)

Minimum Vent Clearancesto Combustibles

UNIT INSTALLATION WITH HORIZONTAL TERMINATION 4" X 6-5/8" VENTING(Rigid Vent Systems)

Below are the recommended framing dimensions (inside measurements) for the 4" x 6-5/8" rigid vent terminations - for use with a firestop or wall thimble.

* Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination where the use of a firestop or wall thimble reduces clearance to 1-1/2" (38mm).

CL

CL

3" (

mm

)6

914

Min

. he

ight

(Fle

x or

Rig

id)

centerof hole

Page 35: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 35

35| installation

1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit). Locate the centerline of the termination and mark wall accordingly. Cut an square hole in the wall - see chart (inside dimension).

Note: If installing termination on a siding cov-ered wall, a vinyl siding standoff or vinyl furring strips must be used to ensure that the termination is not recessed into the siding.

2) Level the fireplace and fasten it to the framing using nails or screws through the nailing strips.

3) Assemble the vent assembly by applying Mill Pac to the inner flue collar of the termination and slipping the inner flex liner over it at least 1-3/8" (35mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill Pac to the outer flex pipe and slip it over the outer flue collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 screws.

11�(294mm)

11�(294mm)

ASTROCAPDIMENSIONS (946-523/P)

Minimum Vent Clearancesto Combustibles

UNIT INSTALLATION WITH HORIZONTAL TERMINATION 4" X 6-5/8" VENTING(Flex Vent Systems)

NOTE: Horizontal sections must be support-ed at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner).

4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.

5) Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap to show which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws.

6) Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fireplace. (You may wish to cut the liner shorter to make it more workable.) Do not bend liner more than 90o. The liners must slip over the collars a minimum of 1-3/8".

7) Apply Mill Pac over the fireplace inner flue collar and slip the inner flex liner down over it and attach with 3 supplied screws.

8) Do the same with the outer flue collar and outer flex liner.

9) Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the water out.

IMPORTANT: Do not locate termination hood where excessive snow or ice buildup may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

* Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination where the use of a firestop or wall thimble reduces clearance to 1-1/2" (38mm).

Recommended Framed Opening Size

Vent Size Framing Size

4" x 6 - 5/8" 10" x 10"

Below are the recommended framing dimensions (inside measurements) for the 4" x 6-5/8" and 5" x 8" rigid vent terminations - for use with a firestop or wall thimble.

Horizontal Top* 3" (76mm)*

Horizontal Side 2 " (51mm)

Horizontal Bottom 2" (51mm)

Vertical Vent 2" (51mm)

Page 36: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

36 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 36 installation

Diagram 4

Diagram 3: The upper half of the flashing is in-stalled under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments.

Diagram 2

UNIT INSTALLATION WITH VERTICAL TERMINATION4" X 6-5/8" VENTING

(Rigid Vent Systems)

1) Maintain the 1-1/2" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. Check "Venting" Sections for the maximum vertical rise of the venting system and the maximum horizontal offset limitations.

2) Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof.

3) A Firestop spacer must be installed in the floor or ceiling of every level. To install the Firestop spacer in a flat ceiling or wall, cut a 10 inch square hole. Frame the hole as shown in Diagram 2 and install the firestop.

NOTE: For best results and optimum perfor-mance with each approved venting system, it is highly recommended to apply “Mill-Pac” seal-ant (supplied) to every inner pipe connection. Failure to do so may result in drafting or per-formance issues not covered under warranty.

4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow con-nections are in the fully twist-locked position and sealed.

5) Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2. The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles of 1-1/2". Slip the flashing under the shingles (shingles should overlap half the flashing) as per Diagram 3.

6) Continue to assemble pipe lengths.

Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose.

Galvanized pipe is desirable above the roofline

due to its higher corrosion resistance. Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Dia. 4 or local codes. Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem.

7) Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic.

8) Install the vertical termination cap by twist-locking it.

Note: Any closets or storage spaces, which the vent passes through must be enclosed.

Diagram 1

Note: All vertical terminations are vent-ed using 4" x 6-5/8" venting and rigid pipe adaptor #510-994.

Roof Pitch Minimum Vent Height

Feet Meters

flat to 7/12 2 0.61

over 7/12 to 8/12 2 0.61

over 8/12 to 9/12 2 0.61

over 9/12 to 10/12 2.5 0.76

over 10/12 to 11/12 3.25 0.99

over 11/12 to 12/12 4 1.22

over 12/12 to 14/12 5 1.52

over 14/12 to 16/12 6 1.83

over 16/12 to 18/12 7 2.13

over 18/12 to 20/12 7.5 2.29

over 20/12 to 21/12 8 2.44

Page 37: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 37

37| installation

HIGH ELEVATION

This unit is approved for altitude 0 to 4500 ft. (CAN1 2.17-M91).

GAS LINE INSTALLATION

Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.

For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement.

NOTE: A shutoff / dante valve should be sup-plied in or near the unit (or as per local codes) for ease of servicing this appliance.

IMPORTANT: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.

HZ42STE-NG10 SYSTEM DATAMin. Supply Pressure 5" WC (1.25 kpa)

Low Setting Man. Pressure

1.6" WC (0.40kpa)

Max. Manifold Pressure

3.5" WC (0.87 kpa)

Orifice Size #40 DMS

Minimum Input 17,500 Btu/h (5.13 kW)

Maximum Input 26,000 Btu/h(7.62 kW)

HZ42STE LP10 SYSTEM DATAMin. Supply Pressure 12" WC (2.98 kpa)

Low Setting Man. Pressure

6.4" WC (1.59kpa)

Max. Manifold Pressure

10" WC (2.49 kpa)

Orifice Size #53 DMS

Minimum Input 19,500 Btu/h (5.71 kW)

Maximum Input 24,500 Btu/h(7.18 kW)

AERATION ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame.

Minimum Air Shutter Opening:

NG Fully ClosedLP 3/16"

With Logs:NG 1/4"LP Full open

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

GAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.

The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1) Make sure the valve is in the "OFF" position.

2) Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a

1/8" wide flat screwdriver.

3) Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4) Light the pilot and turn the valve to "ON" position.

5) The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten.

Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner.

Note: If you have an incorrect flame pattern, contact your Regency® dealer for further instructions.

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the burner or thermopile or thermocouple.

PILOT ADJUSTMENT

Burner

Flame Sensor

Pilot Ignitor

885 S.I.T. VALVE DESCRIPTION

1) 6 Stage flame adjustment2) Pilot adjustment3) Outlet Pressure Tap4) Inlet Pressure Tap5) Pilot Outlet6) Main Gas Outlet7) Main Gas Inlet

1

2

34

6

5

7

Page 38: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

38 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 38 installationWIRING DIAGRAM

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.

This heater does not require a 120V A.C. supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries. In case of a power failure, the remote control will continue to operate if batteries are installed in the receiver.. However, a 120V A.C. power supply is needed for the AC adaptor.

(Do not cut the ground terminal off under any circumstances.)

Proflame SystemConfiguration886 GTMFWire Diagram

SureFire™ Switch

885

1 of 10

AC Adaptor

Page 39: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 39

39| installation

OPTIONAL WALL THERMOSTAT INSTALLATION

This installation must be completed during initial install with the front access panel removed.

A wall thermostat may be installed if desired.

Recommended: The wall thermostat should be mounted beside the Remote/Unit Receiver which comes standard with the appliance.

1) Run wires from thermostat into the unit.

2) Remove the green wire marked (TH) at the white connector-shown below. The noted wires will be located near the gas valve.

Disconnect greenTH wire

Green Wires

White Connector

3) Connect one thermostat lead to female connector, using male spade connector - see picture below.

CAUTIONDo not wire

Thermostat wiresto 120V wire.

4) Connect the other thermostat lead to male connector disconnected from Step1using a female spade connector - see picture below.

When complete turn remote receiver to the ON position. Unit will now operate using the wall thermostat.

NOTE: When the remote receiver is set to ON position, the remote control transmitter and all of its features are now dis-abled.

Page 40: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

40 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 40 installation

AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS)An AC power adaptor is supplied with this appliance and may be installed as a constant power source for the SureFire system.

NOTE: AC power adaptor is not required when using GTMF Remote with fan control module and must be disconnected.

IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver. This will avoid battery leakage and power drainage. 4-AA Battery pack may be re-installed into receiver during power outages.

919-063 10/09/14

1. Plug AC adaptor into a 120V wall outlet or into the 120V receptacle if installed inside the gas fireplace.

2. Tuck any loose wires neatly underneath the firebox–inside the fireplace.

Note: Ensure that wires do not touch the underside of the fire box (Keep wires away from heat as much as possible).

AC adaptorWire adaptor

1

AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS)

OPTIONAL WALL THERMOSTAT

A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length.

Note: Preferable if the thermostat is installed on an interior wall.

Regency® offers an optional programmable thermostat but any 250-750 millivolt rated non-anticipator type thermostat that is CSA, ULC or UL approved may be used.

Thermostat Wire Table

Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System)

Wire Size Max. Length

14 GA. 50 Ft.

16 GA. 32 Ft.

18 GA. 20 Ft.

20 GA. 12 Ft.

22 GA. 9 Ft.

CAUTIONDo not wire millivolt

wall thermostat wiresto 120V wire.

Page 41: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 41

41| installationOPTIONAL REFLECTIVE PANEL INSTALLATION

918-830a 01/05/151

HZ42 ST

OPTIONAL REFLECTIVE PANEL INSTALLATION

1) Remove the faceplate and glass door if already installed - see manual for instructions.Note: Only one glass door needs to be removed - not both.

2) Remove the top deflector - located on the inside top of the unit - by removing 4 screws - as shown below.

2) Fit the back panel into position by clearing the pilot shield and fit the

3) Loosen screw securing the panel clip located in the middle of the side panel - inside the firebox.

The screw is on the top inside of the firebox.

6) With panel in position - retighten screw to secure panel clip.

7) Repeat steps 3-5 on opposite side.

8) Reverse step 2 and 1.

4) Orient the panel with the folds facing the wall of the firebox. The thin unfolded edge should be facing down towards the floor of

the firebox.

5) Slide the panel in between the side wall of the firebox and the panel clip - adhere to all handling instructions.

Thin edge faces downward

Panel Clip

Fold facingin

Thin edge facing down

Black Enamel Panels

• Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration.

• Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect.

* All hand and finger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any finger-prints before applying heat to the unit.Failure to do this will result in burn stain on panels which you will be unable to remove. Not protected by product warranty.

Page 42: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

42 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 42 installation

GLASS CRYSTALS OR OPTIONAL STONES INSTALLATION

Spread the Glass Crystals or Stones evenly over the burner. Ensure the crystals/stones do not overlap excessively as this will affect the flame pattern.

IMPORTANT NOTE:Only the supplied approved Glass Crystals and Stones are to be used with these fireplaces. Use of any other type of glass crystals or stones can alter the unit's performance. Any damage caused by the use of any unapproved glass or stones will not be covered under warranty.When using Ceramic Spa/Volcanic Stones ensure required glass crystals/beads are used as a base. DO NOT overstack Ceramic Spa Stones or Volcanic Stones on burner or in the pilot area.

BURNER PACKAGESUnit *Glass Crystals Fire Beads Stones - Spa / Ceramic / VolcanicHZ42STE 2lbs 3lbs 1.5 lb Glass + 30 Ceramic Stones or 1.5 lb Glass + 25 Volcanic Stones

2 lb Beads + 30 Ceramic Stones or 2 lb Bead + 25 Volcanic Stones

NOTE: * Glass Crystals are not supplied with the unit. Must purchase separately - see quantities above

OPTIONAL PEBBLES / GLASS CRYSTAL INSTALLATION FOR FIREBOX BASE (AROUND BURNER)

Firebox (Around Burner) PackagesUnit Glass Crystals Fire Beads Pebbles

HZ42STE 5 lbs 5 lbs 2 packages (6 x bags pebbles)

There are 2 optional packages to choose from to cover the firebox base:1) Natural River Pebbles2) Glass Crystals (4 colors available)

Spread the pebbles / crystals evenly on the exposed base of the firebox. Pebbles are NOT to be placed anywhere on the burner or over top of the Glass Crystals or optional Stones.IMPORTANT NOTE: Only the supplied and approved pebbles / glass crystals are to be used with these fireplaces. Use of any other type of pebbles, glass

crystals or other material can create a danger and will void the warranty.

Optional Volcanic Stones + Glass Crystals shown on burner.

Natural River Pebbles shown surrounding the Horizon Burner

Glass Crystals shown surrounding the Burner

Page 43: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 43

43| installationOPTIONAL LOG SET INSTALLATION

919-289 09/11/13

Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.

Improper positioning of the logs and lava embers may create carbon build-up and can alter the unit's performance which is not covered under warranty.

*Satin paint is included if touch ups are required.

1 Front Left Log (front side)

2 Front Left Log (back side)

3 Cross Log (front side)

4 Cross Log with 'Y' (front side)

5 Cross Log (back side)

6 Cross Log with 'Y' (back side)

7 Log piece (front side)

8 Log piece (back side)

Lava Embers / Rocks

1. S hut off gas and electrical supply, allow unit to cool to room temperature.

2. Remove both faceplates and fl ush glass doors (see unit manual).

3. Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care - never force into position.

4. Ensure glass crystals are installed on the burner. HZ42STE = 2lbs

5. Locate and install paper templates on both sides of fi rebox base as shown below.

Front and back paper templates in position

6. Install Log 1 on the far left side of the front of the unit - use the tem-plate to determine position of Log . Repeat on the back side of the unit with Log 2.

1

23 4 65

7

8

1

3

4

13 57

86

4 2

7. Assemble Logs 3 + 4 as shown below. Match up pin landing on Log 3 with pin on Log 4. The other part of the 'Y' of Log 4 should rest on the notch in Log 3 as shown below.

Logs installed on one side of the unit are mirrored on the opposite side and therefore installed in the exact same manner.Below is an overview of the completed install.

Notch in Log 3

Front

Back

Diagram 1

Diagram 2

Diagram 3

Diagram 4

Diagram 5

1

HZ42STE

HZ42STE - LOG INSTALLATION

Page 44: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

44 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 44 installation

919-289 09/11/13

HZ42STE - Final Install

12. Place lava embers/rocks on glass - ensure rocks do not block pilot. Do not place lava rocks/embers too close to logs as this may cause carboning.

13. Carefully remove paper templates.

14. Adjust aeration, see unit manual for setting.

15. Reverse Steps 2 and 1.

8. Install on burner, use template to determine the fi nal position 9. Repeat the procedures in Steps 7 and 8 to assemble and install Logs 5 + 6 on the other side of the unit

10. Install Log 7 - line up pin locator with pin on Log 3 as shown below. Line up other end of Log 7 with template.

11. Install Log 8 - line up pin locator with pin on Log 5. Line up other end of Log 8 with template.

3 4

7Diagram 6

Diagram 7

Diagram 8

2

HZ42STE

Page 45: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 45

45| installation

GLASS DOOR INSTALLATION

FlushDoor

Hook top ofdoor ontotop flange

The glass door comes with a black frame. 1) To install the frame and glass door, simply hook the top door flange onto the top of the unit and swing the door towards the unit, Diagram 1.

Note: Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. See Diagram 2.

2) With the door in proper position - secure with 3 screws in locations shown in Diagram 3.

Diagram 2

Diagram 3

Diagram 1

Page 46: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

46 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 46 installation

919-452 01.05.151

SAFETY SCREEN / INNER DOOR FRAME REMOVAL/INSTALLATIONTHE INNER DOOR FRAME (3) MUST BE PURCHASED SEPARATELY IN EITHER STAINLESS STEEL OR BLACK

1. The inner door trim (1) and safety screen (2) come attached to the fireplace. Remove the inner door trim and safety screen by pulling the bottom of the trim towards you as one, then lift up.

3. Install screen into inner door frame - secure safety screen by bending in 6 tabs in locations shown below.

4. Hook the inner door frame (3) and safety screen assembly (2) over the inner door trim.

1

5. Bend the center tab up and secure with a screw to attach the inner door frame/safety screen assembly to the inner door trim

6. Attach completed assembly to the glass door on unit.

7. Secure the assembly with 1 screw on each side.

2

3

Tabs

2. Remove screws from inner side of the inner door trim and discard screws and the brackets. (Brackets not shown). Remove the screen mesh from inner door trim.

Screw Locations

8. HZ42STE only - repeat Steps 1-7 to install screen and door frame on other side.

SAFETY SCREEN/ INNER DOOR FRAME REMOVAL/INSTALLATION

Page 47: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 47

47| installation

OUTER DOOR FRAME INSTALLATION

919-452 10.30.14

Completed inner and outer door frame and

installation

1) Install the outer door frame to the unit by hooking the left and right side mounting brackets into the mounting slots at the side of the firebox as shown below. It is recommended that you use the first mounting slot (the one closest to the door frame overlay) out of the 3 so that the faceplate and door frame overlay are flush with one another.

NOTE: There are 3 mounting slots available, this is to accommodate

any finishing that protrudes slightly beyond the faceplate.

Tab on Faceplate

Bracket in Unit

Note: Inner door frame may be installed by itself, or with the outer door frame. The outer door frame cannot be installed by it-self - if installing the outer door frame - the inner door frame must also be installed.

1

OUTER DOOR FRAME INSTALLATION

Mounting Slots

Page 48: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

48 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 48 installation

FACEPLATE INSTALLATION

919-073a 01/05/15

3) To install the 4 piece faceplate - hook brackets (located on back of faceplate) over the two middle tabs on the glass door frame.

If thicker finishing materials are used - the faceplate may be adjusted out - up to 1/2".

4) HZ42STE-10 ONLY - repeat Steps 1-3 to install faceplate on other side.

HZ40E

HZ42STE

1

3"(76mm)

3"(76mm)

VERONA / 4 PIECE FACEPLATE INSTALLATION

Important: 1/2" gap required between faceplate and finished wall.

1) When installing required Safety Screen - See "Safety Screen" instal-lation instructions.

2) Install brackets onto the back of the faceplate - 3 screws for each bracket in locations shown below.

Hook bracket over these tabs

Final Install

+1/4"

+1/2"

Use first notch in bracket for standard installation

Page 49: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 49

49| operating instructions

OPERATING INSTRUCTIONS

1) Read and understand these instructions before operating this appliance.

2) Check to see that all wiring is correct and enclosed to prevent possible shock.

3) Check to ensure there are no gas leaks.

4) Make sure the glass in the glass door frame is properly positioned. Never operate the appliance with the glass removed.

5) Verify that the venting and cap are unobstructed.

6) The unit should never be turned off, and on again without a minimum of a 60 second wait.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

The FIRST FIRE in your heater is part of the paint curing process. To ensure the paint is prop-erly cured, it is recommended you burn your fireplace for at least four (4) hours the first time.

When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac-turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

NOTE: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE.

FIRST FIRE

NORMAL OPERATING SOUNDS OF GAS APPLIANCESIt is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance.

Burner Tray: The burner tray is positioned directly under the burner and is made of a different gauge material from the rest of the firebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fireboxes.

Pilot Flame:While the pilot flame is on it can make a very slight "whisper" sound.

Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.

Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.

Page 50: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

50 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 50 operating instructionsLIGHTING PROCEDURE

IMPORTANT: The remote control system supplied with this appliance has several options for starting/operating the appliance using the power button and ON/OFF key on the hand held transmitter.

Prior to operating this appliance, please read the remote control operating instructions (packaged with remote control) to understand how to operate this remote control system. Option to download remote functions video with QR code below.

1. Ensure the wall switch/receiver is in the remote position. (see Diagram 1).

3. After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.

4. The unit will turn on.

Note: The first try for ignition will last approximately 60 seconds. If there is no flame ignition (rectification) the board will stop sparking for approximately 35 seconds. After wait time , the board will start second try for ignition by sparking for approximately 60 seconds . If there is still no positive ignition the board will go into lock out.

The system will need to be reset as follows:

a) Turn the system off using ON/OFF switch or press ON/OFF button - if using remote.

b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF button if using remote.

c) Repeat step 2.

ON/OFF Button

Diagram 1

Diagram 2

Set Switch to Remote

SHUTDOWN PROCEDURE1. Turn the wall mounted switch or remote to the "OFF" position.

2. Press "OFF" on the remote control.

3. Turn the gas control knob to the "OFF" position to turn off the pilot.

Remote shown in Manual Mode on Hi

Proflame video

2. Press and release the ON/OFF button on the remote handheld transmitter (see Diagram 2). An audible beep should be heard from the receiver.

Page 51: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 51

51| operating instructions

COPY OF LIGHTING PLATE INSTRUCTIONS

919-401a

A) This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the fl oor because some gas is heavier than air and will settle on the fl oor. WHAT TO DO IF YOU SMELL GAS

- Do not try to light any appliance.- Do not touch any electric switch, do not use any phone in your building.- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.- If you cannot reach your gas supplier, call the fi re department.

C) Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and replace any part of the control system and any gas control which has been underwater.A) Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement. B) AVANT DE FAIRE FONCTIONNER, renifl ez tout autour de l’appareil pour déceler une odeur de gaz. Renifl ez près du plancher, car certains gaz sont pluslourds que l’air et peuvent s’accumuler au niveau du sol. QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : • Ne pas tenter d’allumer d’appareil • Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le bâtiment. • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. • Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendiesC) N’utilisez pas cet appareil s’il a été plongé dansl’eau, même partiellement. Faites inspecter l’appareil par un tech-

nicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.

DO NOT REMOVE THIS INSTRUCTION PLATE

TO TURN OFF GAS APPLIANCE

This appliance must be installed in accordance with local codes, if any;if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having fl ammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.Une installation, d'ajustement, de modifi cation, de service ou d'entretien peut provoquer des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémen-taires consulter un installateur qualifi é, une agence de service ou fournisseur de gaz.

1) Ensure the wall switch/receiver is in the remote position. 2) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be

heard from the receiver. 3) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.4) The unit will turn on.Note: The fi rst attempt to ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi ca-tion) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the second attempt the board will go into lock out.The system will need to be reset as follows (after going into lock out mode): a) Wait 5 minutes - turn the system off using ON/OFF switch or press ON/OFF button if using

remote b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF button if using remote. c) Unit will repeat step 2.1) S’assurer que l’interrupteur mural/récepteur soit en position télécommande. 2) Appuyer sur la touche ON/OFF de la télécommande et relâcher. Un bip sonore se fera entendre depuis le récepteur3) Après environ 4 secondes, le système d'allumage des étincelles pendant 60 secondes pour allumer le brûleur principal.4) Les fl ammes s’allumeront.Remarque : Au premier allumage, le système tente d’allumer les fl ammes pendant 60 secondes. Si l’essai est infructueux, le système fait une pause de 35 secondes. C’est ce qu'on appelle l'étape de rectifi cation. Ce délai écoulé, le système tente à nouveau d'allumer les fl ammes en produisant des étincelles pendant 60 secondes. Si les fl ammes ne s’allument toujours pas, le système se met en mode verrouillage. Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) : a) Attendre 5 minutes et éteindre l’appareil en réglant l’interrupteur à la position « OFF »; b) Attendre 2 secondes et rallumer le système à l’aide de l’interrupteur ou de la télécommande. c) L'unité répétera l'étape 2.

1) Turn the wall mounted switch or remote to the "OFF" position.2) If service is to be performed–you must disconnect power and shut off gas to the unit.

1) Utilisez l'interrupteur murale ON/OFF du Brûleur ou du contrôle à distance pour éteindre le brûleur.2) Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité.

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

Page 52: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

52 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 52 maintenance

MAINTENANCE INSTRUCTIONS

1) Always turn off the gas and electrical before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.

2) Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner. The glass should be cleaned when it starts looking cloudy.

3) The faceplate is finished in a heat resistant paint and should only be refinished with heat resistant paint. Regency® uses StoveBright Paint - Metallic Black #6309.

Note: Faceplates and inner panels made from stainless steel will naturally change color over time.

4) Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a qualified service person.

5) The appliance and venting system must be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

Note: Never operate the appliance without the glass properly secured in place.

6) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

7) In the event this appliance has been serviced check that the vent-air system has been properly resealed & reinstalled in accordance with the manufacturer's instructions.

8) Verify operation after servicing.

GENERAL VENT MAINTENANCEConduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1) Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.

2) Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3) Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4) Inspect joints, to verify that no pipe sections or fittings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-159).

CAUTION: Wear gloves when removing damaged or broken glass.

WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person.

GLASS DOORYour Regency® fireplace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials.

CAUTION & WARNINGS:

* Do not clean when the glass is hot.* The use of substitute glass will void all product

warranties.* Care must be taken to avoid breakage of the

glass.* Do not strike or abuse the glass.* Do not operate this fireplace without the glass

front or with a cracked or broken glass front.* Wear gloves when removing damaged or broken

glass.* Replacement of the glass panel(s) should be

done by a licensed or qualified service per son.

GLASS REPLACEMENT

In the event that you break your glass by impact, purchase your replacement from an authorized Regency® dealer only.

Replacement neo ceramic glass is shipped with gasket installed.

Page 53: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 53

53| maintenance

VALVE TRAY REPLACEMENT

1) Turn the unit off and allow it to cool down to room temperature.

2) Turn off the gas and electrical supply to the unit.

3) Remove the faceplate,safety screen and glass door–see details in this manual.

4) Remove bottom cover by lifting up and out.

5) Remove burner by removing 2 screws.

6) Slide burner away from the pilot and lift out.

Aerial View of the burner shown.

ON/OFF Connector Wires

7) Remove 7 screws to remove left access panel .

8) Disconnect the ON/OFF connector wires from the valve.

9) Remove 7 screws to remove right side access panel. Disconnect the gas line.

Screw locations

Page 54: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

54 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 54 maintenance

11) Disconnect the inlet gas line and remove the valve assembly.

12) Replace the valve assembly and reverse steps 2-11.

10) Remove the valve assembly by removing the remaining 5 screws on the left side.

X X

XX

X

Page 55: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 55

55| parts list

3

4

57

8

6

2 1

1011

12

2 1011

12

1

MAIN ASSEMBLY

1 Part # Description2 940-361/P Flush Glass

228-023 Flush Glass Frame

3 586-070 Bottom Cover NG / LP

4 586-525 Burner Assembly -NG

586-530 Burner Assembly-LP

6 588-574 E/P Valve Assembly -NG

588-576 E/P Valve Assembly-LP

910-084 Valve only - NG 885

911-085 Valve Only - LP 885

911-010 Stepper Motor - NG 885

911-011 Stepper Motor - LP 88

7 911-006 Pilot Assy - 885 - S.I.T. - NG

911-007 Pilot Assy - 885 - S.I.T. - LP

911-037 Flame Sensor

911-038 Flame Electrode

911-039 2 way pilot hood

910-432 Pilot tube

911-013 Wire Harness Incl. IP/CP switch

8 904-593 Orifice # 40 (NG)

904-345 Orifice # 53 (LP)

910-100 Pilot Orifice - NG

910-101 Pilot Orifice - LP

911-137 Pilot Hood Clip

910-572 Remote receiver

911-127 Remote Receiver Battery Compartment

910-592 Remote Control GTMF (Handheld)

911-032 Remote Wire Harness

946-721 AC Adapter

911-012 DFC Digital Fireplace Control

Part # Description10 258-001 Inner Door Trim

11 258-012 Safety Screen

12 258-964 Inner Door Frame (Black)

12 258-967 Inner Door Frame (Stainless)

910-100 Pilot Orifice - NG

904-658 Inlet Gas Flex Line SS

910-592 Remote Control GTMF (Handheld)

430-011 Flue Collar Gasket

586-047F Relief plate door

586-048 Plate Relief Gasket

586-089 Valve Tray Gasket

430-011 Inner Flue Collar Gasket

586-017F Flue Restrictor Plate

586-016F Gas line cover

596-045 Side nailing strip

919-494 Manual

Page 56: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

56 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 56 parts list

ACCESSORIES

13

14

15

Part # Description 13. 586-908 Black Enamel Inner Panels

14. 258-954 Faceplate Black 258-957 Faceplate Brushed Stainless 256-934 Outer Door Frame Black 256-947 Outer Door Frame Stainless

15 258-964 Inner Door Frame Black 258-967 Inner Door Frame Stainless

256-951 Verona Glass Surround Pure Black 256-955 Verona Glass Surround Chocolate Brown

Part # Description

5 pound bag of glass crystals

946-775 Black Reflective Crystals 946-776 Copper Crystals 946-777 Starfire Crystals 5 pounds bag of Fire Beads

946-739 Black 946-740 Sangria Luster 946-741 Glacier Ice 946-742 Caramel Luster 946-672 Natural River Pebbles 946-674 Ceramic Spa Stones 946-710 Volcanic Stones Slate/Grey 946-711 Volcanic Stones Ivory/Tan

258-900 Steel Stud Framing Kit

Page 57: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 57

57| notes

Page 58: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

58 | Regency Horizon® HZ42STE-10 Gas Fireplace

| 58 notes

Page 59: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Regency Horizon® HZ42STE-10 Gas Fireplace | 59

59| warranty

Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thorough-ly before it leaves our facility. Regency® Fireplace Products is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product. This warranty is not transferable.

The Warranty: Limited Lifetime: The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, glass beads,ceramic spa stones, pebbles, brick panels and gold plating (against defective manufac-ture only) are covered under the Limited Lifetime Warranty for five (5) years for parts and subsidized labour* and parts only thereafter.

Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for five (5) years and parts only thereafter from date of purchase.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date of purchase and parts only thereafter.

Special Finishes - One year on stainless steel panels, enamel panels, Verona glass surrounds, stainless steel inner/outer door frames, inlays, nickel overlays, nickel faceplates, brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. Regency® warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, i.e.. finger prints, etc. applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Electrical and mechanical components such as blowers, fan motors, switches, wiring, thermodiscs, Regency® remote controls, spill switches, thermopiles, thermocouples, pilot assem-bly, Flame sensors, electrodes, fan control modules, IFC/DFC fireplace controls, AC adaptors, and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance. i.e. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.

Regency® venting components are covered parts and subsidized labour* for three (3) years from date of purchase.

Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. Warranty.

Repair/replacement parts purchased by the consumer from Regency® after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid-ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of instal-lation. Reported damage after this time will be subject to rejection.

It is the general practice of Regency® to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to Regency® and evalu-ated for manufacturer defect.

The authorized selling dealer is responsible for all in-field service work carried out on your Regency® product. Regency® will not be liable for results or costs of workmanship from unauthorized service persons or dealers.

At all times Regency® reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to Regency® by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, pur-chase date, serial #, type of unit, problem, and part or parts requested, a copy of the bill of sale/proof of purchase must also accompany any submitted claims, without this information the warranty will be invalid.

Exclusions:This limited Lifetime Warranty does not extend to or include paint, batteries, volcanic stones, lava embers, rockwool, door handles, platinum embers, embaglow embers, door or glass gasketing or trim.

At no time will Regency® be liable for any consequential damages which exceed the purchase price of the unit. Regency® has no obligation to enhance or modify any unit once manu-factured. i.e.. as products evolve, field modifications or upgrades will not be performed.

Regency® will not be liable for travel costs for service work.

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence or accident, spillage or down drafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryer, etc.

It is the responsibility of the home owner to service and maintain the appliance. If any claims are sent to FPI, you may be asked for service records to ensure the appliance has been maintained. Retain all receipts for both service and/or parts which may have been replaced. Lack of service/maintenance is the largest contributor to malfunction of an appliance and is not covered under the terms of this warranty.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

Regency® will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Regency®, may nullify your warranty on this product.

Malfunction/damage of this appliance due to mother nature (wind, rain, snow, floods, etc.) is not covered under the terms of this warranty policy. Some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect and therefore not covered under this Limited Warranty.If the appliance has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals, it will not be covered under this Limited Warranty.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior/exterior facia is not the responsibility of Regency®.

* Subsidy according to job scale as predetermined by FPI.

Gas Product Warranty 2015

Page 60: Regency Horizon HZ42STE Owners ... - Kastle Fireplace Ltd. · Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured

Installer: Please complete the following information

Dealer Name & Address: ______________________________________________

___________________________________________________________________

Installer: ___________________________________________________________

Phone #: ___________________________________________________________

Date Installed: ______________________________________________________

Serial No.: __________________________________________________________

Register your Regency® warranty onlinewww.regency-fire.com

Reasons to register your product online today!

• View and modify a list of all your registered products.• Request automatic email notification of new product updates.• Stay informed about the current promotions, events, and special

offers on related products.

Printed in CanadaRegency Horizon is a trademark of FPI Fireplace Products International Ltd.

© Copyright 2015, FPI Fireplace Products International Ltd. All rights reserved.