Upload
others
View
17
Download
0
Embed Size (px)
Citation preview
Eltek — Gråterudveien 8, PB 2340 Strømsø, 3003 Drammen, Norway Phone: +47 32 20 32 00 Eltek © 2017 – www.eltek.com
Rectiverter Power Core 6 kVA AC 16,8 kW DCUp to 6 kVA AC & up to 16,8 kW 48 VDC outputDoc CTEJ0806.DS3 – rev1
KEY FEATURES 400 VAC +N INPUT THREE PHASE (Y) INPUT SINGLE PHASE OUTPUT 48 VDC INPUT/OUTPUT MAX 6 KVA AC OUTPUT MAX 16,8 KW DC OUTPUT 1 POLE AC DISTRIBUTION OPTION 2 POLE AC DISTRIBUTION OPTION -48 VDC DISTRIBUTION OPTION BUILT IN TRANSFER TECHNOLOGY 150% OVERLOAD CAPABILITY, 15S 600% QUICK TRIP CURRENT, 20MS HOT PLUGGABLE SMARTPACK 2 CONTROLLER SMARTPACK S CONTROLLER OPERATES IN PARALELL WITH
FLATPACK2 RECTIFIERS GLOBAL COMPLIANCE PATENTED HE TECHNOLOGY
Rectiverter Power Core6 kVA AC 16,8 kW DCThe Rectiverter building block combines both AC and DC feed intoone common unit. Simultaneously it provides AC backup power for230 VAC loads, and 48 VDC power for DC loads and batterycharging.
The total DC output can be configured up to 16,8 kW DC loadwhere the limitation for AC load is set to max 6 kVA.The 3phase TN network input balance the load between DC outputand 1phase AC output to reduce the input circuit breaker for thesystem.
APPLICATIONS
TELECOM-MOBILE/WIRELESS
LTE/4G/WiMAX Distributed antenna system Broadband Radio base stations/cell sites
RAILWAY & METRO INFRASTRUCTURE
Control & protection Signaling GSM-R Safety Systems
POWER UTILITIES
Control & protection SCADA system
MODULAR ARCHITECTURERECTIVERTER MODULEThe 3 port converter simultaneouslyprovides power for AC and DC loads.During mains outage the Rectiverter48/1200 HE feeds AC loads using energystored in the battery.
The modular architecture, industry-leadingefficiency, compact size, innovative designand comprehensive monitoring and controlfeatures provide significant benefits overthe current industry standard.
Rectiverter Module
Eltek — Gråterudveien 8, PB 2340 Strømsø, 3003 Drammen, Norway Phone: +47 32 20 32 00 Eltek © 2017 – www.eltek.com
Rectiverter Power Core 6 kVA AC 16,8 kW DCDoc CTEJ0806.DS3 – rev1
MODEL (OPTION 1) 6KVA+12,8 KW DCPart number CTEJ0806.4000
INPUT DATAVoltage range AC (3 phase Y) 320-475 VVoltage range DC 40-58 VMaximum current AC (per phase) 28-48 AFrequency 47-53 / 57-63 HzPower factor > 0.99
OUTPUT DATAAdjustable range AC 200-240 VAdjustable range DC 43-58 VMax output power AC 6,0 kVAMax output power DC 12,8 kWPower factor 0,8Frequency 50Hz, 60 Hz
OTHER SPECIFICATIONS1 pole AC distribuition 10 pc, 2-10 A, C-48 VDC distribution 8 pc, 10-63 A, CBattery breaker (plug-in) 3 pc, 100 A, D
Specifications are subject to change without notice
SINGLE LINE 6 KVA + 12,8 KW DC OPTION 1
FRONT VIEW 6KVA + 12,8 KW DC OPTION 1
Rectiverter 12,8 kW+6 kVA single phase power core (exact distribution see below)
Eltek — Gråterudveien 8, PB 2340 Strømsø, 3003 Drammen, Norway Phone: +47 32 20 32 00 Eltek © 2017 – www.eltek.com
Rectiverter Power Core 6 kVA AC 16,8 kW DCDoc CTEJ0806.DS3 – rev1
MODEL (OPTION 2) 6 KVA+12,8 KW DCPart number CTEJ0806.4001
INPUT DATAVoltage range AC (3 phase Y) 320-475 VVoltage range DC 40-58 VMaximum current AC (per phase) 28-48 AFrequency 47-53 / 57-63 HzPower factor > 0.99
OUTPUT DATAAdjustable range AC 200-240 VAdjustable range DC 43-58 VMax output power AC 6,0 kVAMax output power DC 12,8 kWPower factor 0,8Frequency 50Hz, 60 Hz
OTHER SPECIFICATIONS1 pole AC distribuition 4 pc, 6-10 A, C-48 VDC distribution 14 pc, 10-63 A, CBattery breaker (plug-in) 2 pc, 100 A, D
LVLD 1 pc, 150 A
Specifications are subject to change without notice
SINGLE LINE 6 KVA + 12,8 KW DC OPTION 2
FRONT VIEW 6KVA + 12,8 KW DC OPTION 2
Rectiverter 12,8 kW+6 kVA single phase power core (exact distribution see below)
Eltek — Gråterudveien 8, PB 2340 Strømsø, 3003 Drammen, Norway Phone: +47 32 20 32 00 Eltek © 2017 – www.eltek.com
Rectiverter Power Core 6 kVA AC 16,8 kW DCDoc CTEJ0806.DS3 – rev1
MODEL (OPTION 1) 6 KVA+16,8 KW DCPart number CTEJ0806.4002
INPUT DATAVoltage range AC (3 phase Y) 320-475 VVoltage range DC 40-58 VMaximum current AC (per phase) 28-48 AFrequency 47-53 / 57-63 HzPower factor > 0.99
OUTPUT DATAAdjustable range AC 200-240 VAdjustable range DC 43-58 VMax output power AC 6,0 kVAMax output power DC 16,8 kWPower factor 0,8Frequency 50Hz, 60 Hz
OTHER SPECIFICATIONS1 pole AC distribuition 10 pc, 2-10 A, C-48 VDC distribution 6 pc, 10-63 A, CBattery breaker (plug-in) 3 pc, 100 A, D
Specifications are subject to change without notice
FRONT VIEW 6KVA + 16,8 KW DC OPTION 1
SINGLE LINE 6 KVA + 16,8 KW DC OPTION 1
Rectiverter 16,8 kW+6 kVA single phase power core (exact distribution see below)
Eltek — Gråterudveien 8, PB 2340 Strømsø, 3003 Drammen, Norway Phone: +47 32 20 32 00 Eltek © 2017 – www.eltek.com
Rectiverter Power Core 6 kVA AC 16,8 kW DCDoc CTEJ0806.DS3 – rev1
Rectiverter 16,8 kW+6 kVA single phase power core (exact distribution see below)
FRONT VIEW 6KVA + 16,8 KW DC OPTION 2
SINGLE LINE 6 KVA + 16,8 KW DC OPTION 2
MODEL (OPTION 2) 6 KVA+16,8 KW DCPart number CTEJ0806.4003
INPUT DATAVoltage range AC (3 phase Y) 320-475 VVoltage range DC 40-58 VMaximum current AC (per phase) 28-48 AFrequency 47-53 / 57-63 HzPower factor > 0.99
OUTPUT DATAAdjustable range AC 200-240 VAdjustable range DC 43-58 VMax output power AC 6,0 kVAMax output power DC 16,8 kWPower factor 0,8Frequency 50Hz, 60 Hz
OTHER SPECIFICATIONS1 pole AC distribuition 4 pc, 6-10 A, C-48 VDC distribution 12 pc, 10-63 A, CBattery breaker (plug-in) 2 pc, 200 A, D
LVLD 1 pc, 150 A
Specifications are subject to change without notice
Eltek — Gråterudveien 8, PB 2340 Strømsø, 3003 Drammen, Norway Phone: +47 32 20 32 00 Eltek © 2017 – www.eltek.com
Rectiverter Power Core 6 kVA AC 16,8 kW DCDoc CTEJ0806.DS3 – rev1
Models / ordering information 6kVA+12,8 kW-1 6kVA+12,8 kW-2 6kVA+16,8 kW-1 6kVA+16,8 kW-2Part number CTEJ0806.4000 CTEJ0806.4001 CTEJ0806.4002 CTEJ0806.4003
AC OUTPUT DATAVoltage (default) / (adjustable range) 230 VAC / 200 - 240 VAC
Frequency (default inverter mode) 50 Hz (adaptive)Frequency (set-able inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive)Power maximum (continuous / overload (<15s) ) 4800 W (6000 VA) / 8000 VA
Current maximum (continuous / overload (<15s) ) 26ARMS / 34,8ARMS
Current (maximum) Quick trip (20ms) 120A (6 x nominal)Hold up (Voltage dips) (before switching to battery) > 5 ms @ 4800W loadTHD < 1.5 % at resistive loadOutput features Fuse in L and N, Hot pluggable
DC OUTPUT DATAVoltage (default) / (adjustable range) 53.5 VDC / 43 - 58 VDC
Power (maximum @nominal input) 12,8 kW 1) 12,8 kW 1) 16,8 kW 1) 16,8 kW 1)
Current (maximum @VOUT ≤ 48 VDC) 267 A 1) 267 A 1) 350 A 1) 350 A 1)
Hold up time, maximum output power >10ms; VOUT > 41 VDC
Output features Short circuit proof, Over voltage Shutdown
INPUT DATAAC Mains Input Voltage(3 phase Y) 320-475 VAC
Surge Protection OVP Class 2AC Current/Phase(at nominal output voltage) (depending on module type) 28-48 ARMS
3)
Frequency (default: sync range) 47-53 Hz
Frequency (set-able: sync range) 47-53 Hz, 57-63 Hz or both (adaptive)Power Factor / THD > 0.99 at 50% load or more / < 3.5%DC Voltage nominal / extended range (no overload)2) 45 - 58 VDC / 40 - 45 VDC
DC Current (maximum) 128 A / 180A during overload (15s)
Input featuresFuse in L and N, Hot pluggable, Varistor, Hot pluggable
AC input individual screw terminals 10 mm2 for L1, L2, L3, N & PEBattery breaker (plug-in type), LVBD default 300 A
LOAD DISTRIBUTION 6kVA+12,8 kW-1 6kVA+12,8 kW-2 6kVA+16,8 kW-1 6kVA+16,8 kW-2LVLD - 150 A - 150 A
1 pole AC distribution (L connection on MCB) 2*2A, 4*6A, 4*10A C 2*6A, 2*10A C 2*2A, 4*6A, 4*10A C 2*6A, 2*10A C
-48 VDC distribution (no priority load ) - 2*10A, 2*32A, 2*63A - 2*10A, 2*32A, 2*63A
-48 VDC distribution (priority load) 2*10A, 2*16A, 2*32A, 2*63A 2*10A, 2*32A, 2*63A
Battery breaker 3*100 A, D (plug-in) 2*100 A, D (plug-in) 3*100 A, D (plug-in) 2*200 A, D (plug-in)
OTHER SPECIFICATIONControl and monitoring (see Smartpack datasheet) Smartpack S panel mount
Efficiency >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC))Operating temperature -40 to +55°C (-40 to +131°F), humidity 5 - 95% RH non-condensingStorage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensingDimensions[WxDxH] / Weight 482 x 432 x 267mm (6U) (19 x 17 x 10,6”) / 22kg (48 lbs)
DESIGN STANDARDSElectrical safety EN 60950-1, EN 62040-1 UPS safety
EMC ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15EN 61000-6-1 /-2/-3/-4
Environment ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2)RoHS (2011/65/EU) and WEEE (2002/96/EC) compliant
1) AC load has priority. Maximum available DC output power and current is dependent oninstant AC load and AC input voltage; i.e maximum 11,2kW/15,2kW at full AC power andnominal input for 230VAC.2) 40 - 45 VDC: reduced performance - no power boost and increased voltage THD on ACoutput.
3) If DC voltage is pulled below 43V the input current may increase above this level
Specifications are subject to change without notice