Calderas Baxi Power HT45-150 kW .PDF

Embed Size (px)

DESCRIPTION

Caldera Power HT Baxi Condensación de pie 45-150 kW.

Citation preview

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    1/38135

    Solutions for centralized heating systems installations

    Technical specications

    Dimensions

    Diagrams

    Burner-exchanger unit

    Wiring diagramWiring diagram for connection to an heating system

    DHW circuit electric pump connections

    Flue pipes (B23)

    Dual ue system 45-65 kW

    Dual ue system 85-150 kW

    Electronics

    Programming, setting and digital control

    Single installationSchemes for single installation

    Cascade installation

    Schemes for cascade installation

    Hydraulic separators and condensate neutralizer kit

    Other accessories

    Power HT 45 - 150 kWP.

    136

    137

    138

    139

    140142

    143

    144

    145

    146

    147

    148

    150153

    158

    164

    168

    169

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    2/38136

    1.450 1.650 1.850 1.1000 1.1200 1.1500

    Maximum heating heat input kW 46,4 67 87,2 102,7 123,2 154

    Maximum heating heat output 80/60C kW 45 65 85 100 120 150

    Maximum heating heat output 50/30C kW 48,7 70,3 91,6 107,8 129,7 162

    Minimum heat output 80/60C kW 11,8 13,4 32,2 35,8 39 40,4

    Minimum heat output 50/30C kW 12,8 14,5 34,9 38,8 42,1 43,7

    Energetic efciency (Dir CE/92/42)

    Average efciency (DIN 4702-T8) % 109,8 109,8 109,8 109,8 109,8 109,8

    Nominal efciency 80/60C % 97,3 97,3 97,5 97,4 97,4 97,4

    Nominal efciency 50/30C % 105,2 105,3 105,1 105 105,3 105,2

    Efciency at 30% % 107,6 107,6 107,3 107,4 107,5 107,2

    Load losses water side T=20k kPa 25 20 23,54 22,56 22,56 19,61

    Minimum ow on the exchanger lt/sec 0,27 0,33 0,52 0,58 0,72 0,91

    NOx class (EN 483) 5 5 5 5 5 5

    Minimum working temperature C -5 -5 -5 -5 -5 -5

    Heating system max pressure bar 4 4 4 4 4 4

    Safety valve intervention pressure bar 3 3 3 3 3 3

    Regulation of water temperature

    in heating circuitC 25/80 25/80 25/80 25/80 25/80 25/80

    Primary circuit water ow (T=20C) l/h 1.935 2.795 3.700 4.300 5.200 6.500

    Water content lt 5,1 6,5 13,7 21 23,3 25,3

    Quantity of condensing lt/h 5,1 7,3 9,6 11,5 13,5 16,9

    Flue pipe mm 80 80 100 100 100 100

    Flue ducts max length m 30 20 20 20 20 20

    Maximum ue mass ow rate kg/s 0,022 0,031 0,041 0,049 0,059 0,073

    Minimum ue mass ow rate kg/s 0,006 0,007 0,016 0,018 0,019 0,02

    Maximum ue temperature C 72 73 78 80 77 75

    Residual ue prevalence Pa 130 120 135 150 115 90

    Comburent air-ow at Qn kg/sec 0,022 0,034 0,045 0,055 0,065 0,080

    Dimensions (h x w x d) mm 850x450x621 850x450x693 850x450x801 850x450x871 850x450x1024 850x450x1132

    Net weight kg 60 68 75 83 95 103

    Gas type Natural Gas/CPG Natural Gas/CPG Natural Gas/CPG Natural Gas/CPG Natural Gas/CPG Natural Gas/CPG

    Power consumption W 90 110 100 160 135 235

    Power consumption in stand-by way W 6,3 6,3 6,3 6,3 6,3 6,3

    Power HT 45-150 kWPower HT is the range of high efciency oor standing condensing boilers, heating only with

    an output from 45 to 150 kW (80/60C)

    The range of boilers is distinguished by high efciency, easiness of use/and installation and a

    wide range of accessories for single and cascade installations.

    The main element of these condensing boilers is the heat exchanger that has a combustion

    chamber and a stainless steel AISI 316L coils hydraulic circuit .

    The reduced quantity of water in the exchanger allows a small heat inactivity and so a quick

    answer to the changes in the heat needed by the system.

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    3/38137

    Solutions for centralized heating systems installations

    DimensionsPower HT

    RVA placement

    Depth (A) mm

    45cm

    45cm/2cm

    45cm/2cm

    The stainless steel surfaces protect the exchanger from corrosion due to the condensation.

    The regulation of the various elements of the generator is given to the digital PCB with double micro-processor that allows

    a simple and reliable managing of the boiler through a control panel with wide LCD display. It is possible to set heating and

    DHW mode daily or weekly, the climatic regulation according to the comfort requirements of the end-user; faults and possibleanomalies are shown.

    The electronics of the boiler allow the technician an easy access to regulation parameters to set the boiler in order to optimize

    the performances according to the type of installation.

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    4/38138

    FLOW RATE/HEAD CURVE

    HEAD

    (mH

    20)

    FLOW RATE (l/h)

    EXCHANGER PRESSURE DROPPOWER HT 1.850-1.1000

    Exchangerpressuredrop(mH

    20)

    FLOW RATE l/h

    2000

    5,5

    5,0

    4,5

    4,0

    3,5

    3,0

    2,5

    2,0

    1,5

    1,0

    0,5

    3000 4000 5000 6000

    85 kW

    100 kW

    EXCHANGER PRESSURE DROPPOWER HT 1.1200-1.1500

    Exchangerpressuredrop(mH

    20)

    FLOW RATE l/h

    112-120 kW

    150 kW

    30 35 40

    Efficiencyoftheboiler%

    Return temperature of the system C

    EFFICIENCY OF THE BOILER ACCORDING TO THE RETURN TEMPERATURE

    30% load100% load

    45 50 55 60979899

    100101102103104105106107108

    30 35 40 45 50 55 60303540

    45505560657075

    100% load

    30% load

    Fluestemperature%

    Return tem erature of the s stem C

    FLUES TEMPERATURE ACCORDING TO THE RETURN TEMPERATURE

    EXCHANGER PRESSURE DROP

    POWER HT 1.450-1.650

    Exchangerpressuredrop(mH

    20)

    FLOW RATE l/h

    45 kW

    65 kW

    Diagrams

    The here below graphics, besides better dening the plan of the heating system, allow to deeply analyze the behaviour of thegenerator in different use conditions.

    The load loss of the exchangersdenes the difference of pressure, in mm of water column, between the ow and return

    connections of the generator. The fow rate/ head curveexplains the dynamic features of the BAXI circulator used as accessory

    in these boilers. The performance curvepresents the changing in the efciency, as ratio between the output and input of the

    condensing boiler , according to the return temperature of the boiler.

    Finally the last graphic explains the uetemperature trendsof the boiler according to the return temperature.

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    5/38139

    Solutions for centralized heating systems installations

    Burner-exchanger unit

    The pre mixing air-gas unit, the burner and the primary exchanger are the components that allow these condensing boilers tooffer high performances.

    The pre mixing unit is made of the Venturi pipe in the fan inlet and of the mixer that grant constantly to the burner an optimal

    air-gas ratio independently from the number of turns of the fan limiting to the minimum the consumptions and ensuring always

    the correct combustion (that means reduction of the pollutant emissions).

    The stainless steel burner, through the internal spreader and the special micro-perforation of the cylindrical surface, grants a

    uniform spread of the air-gas mixture independently from his length.

    The primary exchanger, totally made of stainless steel, is built with two cylindrical ue chambers, vertically positioned (burner

    chamber and condensation chamber). Inside the cylindrical surface there are stainless steel coils, in which run the water of the

    primary circuit. In the upper chamber the warm ues discharge gives heat to the return water of the system, contained in the

    coils, provoking the condensation of the ues themselves and giving latent heat to the water, pre-heating it before it enters the

    chamber of the burner.

    Power HT 85-100

    Power HT 120-150

    Power HT 45-65

    Flue outlet

    Flue outlet

    Flue outlet

    PrimaryexchangerPrimary

    exchanger

    Primary

    exchanger

    Condensationchamber

    Condensationchamber

    Condensationchamber

    Chamber ofthe burner

    Chamber ofthe burner

    Chamber ofthe burner

    Coils

    fan

    fan

    fan

    Coils

    Coils

    venturi-mixerunit

    venturi+mixerunit

    venturi-mixerunit

    Burner

    Burner

    Burner

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    6/38140

    Wiring diagram

    IX1-01

    I

    X1-02

    I

    X2-02

    IX2-03

    IX2-04IX2-

    05I

    I

    X3-01

    IX3-02

    IX3-03

    IX3-

    04I

    IX2-01I

    X40

    X30

    X50

    IX10-01IX1

    0-02

    I

    X10-03I

    X10-04

    IX10-05

    IX10-06

    I

    X11

    X12

    X13

    X14

    X15

    1

    2

    1

    2

    1

    2

    1

    2

    3

    1

    1

    2

    1

    2

    1

    2

    1

    1

    2

    3

    1

    2

    12

    10

    98

    76543

    2

    1

    11

    6

    5

    432

    1

    5

    43

    2

    1

    4

    32

    1

    3

    2

    1

    1

    2

    1

    2

    1

    2

    1

    2

    1

    2

    1

    2

    4

    5

    2

    1

    N L

    N L

    ab

    ab

    MAININPUT

    FUSE

    MAINSPOWER230V-50Hz

    MAINSPOWER

    TERMINALBOARD

    DOMESTICHOTWATER

    THANKSENSOR

    g

    g

    COM

    NOgg

    LN

    IGNITION

    ELECTRODE

    REMOTECONTROLLER

    CONNECTION

    ROOMTHERMO

    STAT

    SAFETYSHUT-D

    OWN

    OUTDOORSEN

    SOR

    SAFETY

    THERMOSTAT

    FLAMESENSING

    ELECTRODE

    12 34 56 78 910

    PROGRAMMABLE

    OUTPUT230V

    INTERFACEBUS

    FORBOILERS

    IN

    CASCADE

    CLIP-INMO

    DULE

    TOCONTRO

    LTHE

    MIXINGZ

    ONE

    DISPLAY

    CENTRALHEATING

    SYSTEMPUMP

    CONNECTIONPOINTS

    17

    16

    15

    14

    13

    12

    11

    FUMES

    THERMOSTAT

    NTCDELIVERY

    HEATINGSENSOR

    NTCRETURN

    HEATINGSENSOR

    IGNTER

    HYDRAULIC

    PRESSURE

    SENSOR

    DOMESTICHOT

    WATERPUMP

    CONNECTIONPOINTS

    FAN

    b

    brbk

    br

    br

    b

    br

    br

    b

    b

    y/g

    b

    brb

    br

    b

    b

    b

    bbr

    b

    bb

    kbkr

    r

    g

    gbrbr

    b

    y/g

    bk

    br

    bbr

    b

    br

    br

    br

    b

    b

    C

    M

    GASVALVE

    V1V2

    INOUT

    MIN

    rr

    nn

    y/g

    y/g y

    /g

    y/g

    G/V

    Power HT 1.450 - 1.650 - 1.850 - 1.1000The picture explains the wiring diagram of the PCB of the boiler. Sensors and functional components of the generator are

    controlled by the PCB to which they are connected through the internal connectors shown in the picture.

    Other 3 connectors reachable from outside the PCB are available to check service devices and regulation of the system (pumps,

    outdoor sensor, room thermostat etc) .

    Colourofthe

    cables:

    C=

    lightblue

    M=

    brown

    N=

    black

    R=

    red

    G/V=

    yellow/green

    B=

    white

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    7/38141

    Solutions for centralized heating systems installations

    Wiring diagram

    IX1-01

    I

    X1-02

    I

    X2-02

    IX2-03

    IX2-04IX2-05I

    IX3-01

    IX3-02

    IX3

    -03

    IX3-04I

    IX2-01I

    X40

    X30

    X50

    IX10-01I

    X10-02IX10-03IX10-04IX10-05IX10-06

    I

    X11

    X12

    X13

    X14

    X15

    1

    2

    1

    2

    1

    2

    1

    2

    3

    1

    1

    2

    1

    2

    12

    1

    1

    2

    3

    1

    2

    12

    109876543

    21

    11

    6

    5432

    1

    5

    432

    1

    4

    32

    1

    3

    2

    1

    1

    2

    1

    2

    1

    2

    1

    2

    1

    2

    1

    2

    IGNITION

    ELECTRODE

    4

    5

    2

    1N

    L

    N L

    ab

    ab

    MAININPUT

    FUSE

    230V-50Hz

    br

    -brow

    n

    bk

    -black

    b

    -blue

    r

    -red

    g

    -green

    g/y-gree

    n/yellow

    w

    -white

    DOMESTICHOTWATER

    TANKSENSOR

    g

    g

    ggg

    y/g

    COM

    NO

    g

    gg

    LN

    MG/V

    C

    REMOTECONTROLLER

    CONNECTION

    ROOMTHERMOSTAT

    SAFETYSHUT-DOWN

    CENTRALHEATING

    TEMPERATURESENSOR

    OUTSIDESENSOR

    SAFETY

    THERMOSTAT

    FLAMESENSING

    ELECTRODE

    SPARK

    GENERATOR

    12 34 56 78 910

    PROGRAMMABLE

    OUTPUT

    INTERFACEBUS

    FORBO

    ILERSIN

    CASCADE

    CLIP-INMODULE

    TOCONTROLTHE

    MIXINGZONE

    DISPLAY

    17

    16

    15

    14

    13

    12

    11

    WATER

    PRESSOSTAT

    20

    19

    18

    FUMES

    THERMOSTAT

    FAN

    b

    brbk

    br

    br

    b

    br

    br

    b

    b

    y/g

    b

    brb

    br

    b

    b

    bb

    br

    b

    b

    bkbkr

    r

    g

    gbrbr

    rr

    b

    y/g

    bk

    br

    bbr

    PS

    b

    br

    br

    br

    b

    b

    GASVA

    LVE2

    C

    M

    GASVALVE1

    OUT IN

    PILOT

    AIRIN

    OUT IN

    PILOT

    AIRIN

    y/g

    y/g y

    /g

    y/g

    G/V

    CENTRALHEATING

    SYSTEMPUMP

    CONNECTIONPOINTS

    DOMESTICHOT

    WATERPUMP

    CONNECTIONPOINTS

    Power HT 1.1200 - 1.500

    Colourofthec

    ables:

    C=

    lightblu

    e

    M=

    brown

    N=

    black

    R=

    red

    G/V=

    yellow/green

    B=

    white

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    8/38142

    High output oor standing boilers can be easily connected to a heating system through the use of terminal boards which areinside the dashboard. The connections with scheme and indications are shown in the picture below. The pumps of the heating

    system (P1 and P2) have to be fed following the scheme of the picture interposing between the PCB of the boiler and the pumps

    some relays.

    It is not necessary to interpose a relay if, to the PCB is wired a single pump.

    Wiring diagram for connection to an heating system

    P1 = Pump of the hydraulic separator

    P2 = Heating system pump

    SI = Hydraulic separator (available as accessory)

    UR = Heating Unit

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    9/38143

    Solutions for centralized heating systems installations

    DHW circuit electric pump connections

    The connection of BAXI POWER HT boilers to an indirect cylinder for DHW production can be easily made respecting theconnections indicated in the here below picture.

    The pump of the sanitary circuit P3, serving an indirect cylinder, must be linked on the Terminal board M3 of the boiler to the

    terminals 13-14. Connecting the pump of the sanitary circuit P3 after an hydraulic separator (as explained in the drawing)

    Link the NTC sensor of sanitary priority, supplied as accessory, to the 9-10 terminals of the terminal board M2 after having

    removed the actual power resistance.

    The sensible element of the NTC sensor has to be put in the relevant well foreseen on the cylinder (see drawing)

    The regulation of the DHW temperature and the choice of the sanitary hourly programming can be made directly on the control

    panel of the boiler.

    DHW TANK CONNECTION DIAGRAM

    UB - DHW STORAGE TANKM2 - TERMINAL BOARDSB - DHW PRIORITY SENSORRE - RESISTOR TO BE REMOVED

    MR - CENTRAL HEATING FLOWRR - CENTRAL HEATING/DHW RETURNMB - DHW STORAGE TANK FLOWRB - DHW STORAGE TANK RETURNP1 - CENTRAL HEATING PUMPP3 - DHW STORAGE TANK PUMPTS - SAFETY THERMOSTATPS - SAFETY PRESSURE SWITCH

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    10/38144

    Flue pipes

    Power HT, open ue range of boilers, are certied for a B23 type of installation. This means that the boiler has to be connectedto a chimney through a stainless steel or plastic pipe with an internal diameter of 80 mm (Power HT 1.450 and Power HT 1.650)

    or internal diameter 100 mm (Power HT 1.850-1.1000-1.1200-1.1500). There are available accessories in smooth PP with a

    80 mm and 110 mm diameter. To use 110 mm ue accessories made of PP it is necessary to use an adaptor 100/110 available,

    as well, as optional.

    Important: the horizontal stretches must have a slope towards the boiler of 3.

    Chart of the available pressures of the ue pipes

    Cascade installation

    ModelP available with

    Flue pipe B23 100P available with

    Single clapet 110/110P available with

    Double clapet 110/110

    HT 1.450 150 110 (with Clapet 80/110) -

    HT 1.650 150 100 (with Clapet 80/110) -HT 1.850 110 110 -

    HT 1.1000 150 110 -

    HT 1.1200 170 - 80

    HT 1.1500 280 - 120

    Model Max length of the ue pipe-L- (m)For each 90 bend installed the length

    decreases of (m)For each 45 bend installed the length

    decreases of (m)

    HT 1.450 30 1 0,5

    HT 1.650 20 1 0,5HT 1.850 20 1 0,5

    HT 1.1000 20 1 0,5

    HT 1.1200 20 1 0,5

    HT 1.1500 20 1 0,5

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    11/38145

    Solutions for centralized heating systems installations

    Dual ue system accessories

    Picture Description Code

    C53 conversion kit Power HT 45-65 kW LSB 710000100

    PP pipe extension 80 L=1000 mm KHG 714059411 .

    PP pipe extension 80 L=500 mm KHG 714059910 .

    PP pipe extension 80 L=250 mm 710718301 .

    PP 90 bend 80 KHG 714059211 .

    PP 45 bend 80 KHG 714059311 .

    Pipe 80 centring kit (pack of 5) KHG 714037411 .

    Clamp centring kit 80 KHG 714106110 .

    Pipe 80 supporting bracket (pack of 5) KHG 714037310 .

    Internal sealing collar 80 KHG 714018510 .

    External sealing collar 80 KHG 714018411 .

    Flue terminal 80 LSD 790000150 .

    Dual ue terminal 80 KHG 714010410 .

    45-65 kW

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    12/38146

    Flexible ducting system accessories

    Picture Description Code

    PP exible pipe 80 L= 1,5 m KHG 714105710 .

    PP exible pipe 80 L= 20 m KHG 714105810 .

    PP tee-joint 80 with supporting bracket andcondensate drainings

    KHG 714105910 .

    PP 90 bend 80 with supporting bracket (packof 3)

    KHG 714106010 .

    Flexible centring kit 80 (pack of 3) KHG 714106210 .

    Triple lips gaskets kit 80 (pack of 5) KHG 714111210 .

    Dual ue system accessories85-150 kW

    Picture Description Code

    C53 convension kit Power HT 85-100 kW LSB 710000110

    C53 convension kit Power HT 125-150 kW LSB 710000120

    PP pipe extension 110 L=1000 mm KUG 714133210 .

    PP pipe extension 110 L=500 mm KUG 714133110 .

    PP pipe extension 110 L=250 mm 710718501 .

    PP reduction kit from 110 to 100 KHW 714096910 .

    PP 90 bend 110 KUG 714133010 .

    PP 45 bend 110 KUG 714132910 .

    45-65 kW

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    13/38147

    Solutions for centralized heating systems installations

    Electronics

    Settingheatingmode

    Information:-DHW temperature-Outside temperature(if connected to theoutdoor sensor)

    DHWON-OFF

    DHW temperatureregulation

    Reset

    Programmesaccessand shift

    Programmesaccess

    and shift

    Parametersregulation(decrease value)

    Parametersregulation(increase value)

    Heatingtemperatureregulation

    Power HT range of boilers is provided with a wide digital control panel: dedicated push-buttons for each single function and LCDdisplay combining symbols and codes for information about the boiler working status allowing an easy reading and an immediate

    parameter control, programming and setting.

    Microprocessor with double CPU: a new technology software for the boiler optimal operation

    Built-in daily timer to program both central heating and DHW functions

    Programmable pre-heating function of the DHW circuit to reduce waiting times

    Digital electronic thermometer

    Self-check: detection and description of any possible fault

    Built-in climatic regulation (outdoor sensor supplied as optional)

    Automatic summer/winter switch with outdoor sensor connected

    Cascade system installation option Mixing systems (high and low temperature) installations option

    Interface PCB, available as optional, connectable for supplementary functions such as remote control of fault/operation

    signals, control of additional pumps, control of boiler output by an external electronic device, etc.

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    14/38148

    Programming, setting and digital control

    Picture Model Description Code

    Boiler interface for mixing

    systems with two different

    temperatures zones

    Through this accessory the boiler is able tomanage a mixing system with a high and a lowtemperature zone. The accessory managesdirectly the components of the low temperaturecircuit as the mixing valve, the circulating pumpand the NTC sensor, to measure the temperatureof this circuit.

    KHG 714077913 .

    Boiler control interface 0-10 V

    Through this accessory the boiler is able to

    change the heat output according to a voltagesignal (010V) coming from a programmablecontroller (PLC) out of the boiler. Then, it ispossible to connect the outdoor lamps to showthe block of the system or functioning.

    KHG 714107612 .

    Remote controller and climaticregulator

    Climatic regulator, directly connectable to theboiler. It allows the data exchange with the PCBof the boiler. Besides the crono-thermostat andclimatic regulator functions it is also a remotecontrol that allows the regulation of parametersof the boiler.

    KHG 714072612 .

    Outdoor sensor

    The outdoor sensor is a temperature indicatorthat communicates to the boiler the outdoortemperature so that the boiler adapts the owtemperature to the comfort set by the end-user.

    KHG 714072811 .

    Temperature regulator formixing systems, it includes a

    temperature sensor

    The temperature regulator that allows to controla mixing zone (a low temperature zone). It isable to manage a mixing valve, a pump and a

    ow sensor of the controlled zone. Then, it canexchange data with the PCB of the boiler by bus.

    KHG 714078112 .

    Bus interface for climaticregulators for boilers in cascade

    It is an electronic device that allows dataexchange by bus between the electronics and thetemperature regulators.The interface allows also the remote control oftheboiler

    KHG 714078013 .

    Cascade controller, it includes atemperature sensor

    Temperature regulator for cascade systems,allows up to 12 boilers connection ensuringfunctioning and efciency optimization. Itmanages a high temperature zone with its pump,a storage tank with its pump and temperaturesensor.

    KHG 714078212 .

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    15/38149

    Solutions for centralized heating systems installations

    DimensionsPower HT from 45 to 150 kW

    936,5

    136,5

    800

    526

    678,5

    524

    400

    800

    186,5

    850

    986,5

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    16/38150

    Single installationwith Power HT boilers from 45 to 150 kW

    Safety valve

    Non-return valve

    Shut-off valve

    Boiler-manifold pipe hydraulic connection

    Manifold pipes single boiler/last boiler

    Second pump hydraulic connection

    Return manifold

    Flow manifold

    Extension vessel hydraulic connection

    Shut-off valve

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    17/38151

    Solutions for centralized heating systems installations

    Single installation

    Manifold pipes single boiler/last boilerPower HT models Code Kit made of:

    45-150 kW KHW 714104210 . Flow manifold

    Return manifold

    Second pump hydraulic connection

    Power HT models Code Kit made of:

    45-150 kW KHW 714098611 .

    2 way shut-off valveUPS32/80 circulating pumpNon-return valveHydraulic joints

    Boiler-manifold pipe hydraulic connection

    Power HT models Code Kit made of:

    45-150 kW KHW 714104311 .

    2 way shut-off valve on returnCirculating pump UPS 32/80Non-return valveExtension vessel hydraulic connection3 way shut-off valve on ow

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    18/38152

    Controller - bus interface connection

    Bus interface is an electronic device that allows data exchange by bus between the PCB and the temperature regulator.

    After removing the cover of the control panel, mount the plate (B) supplied with the bus interface, and so mount the accessory as

    well (C). The at cable (A) have to be linked to the connector X40 of the electronics of the boiler. Connect the wiring (respecting

    the polarity) between the connector X41 of the bus interface and the connector MB-DB of the controller.

    Note: to make the connection easy between the accessory and the PCB, connect the wiring (A) to the PCB before xing the plate

    (B). To allow the mounting of the cover of the control panel it is necessary to cut the two plastic pins which are on the cover just

    next to the bus interface.

    Bus interface for climatic

    regulators for boilers in cascade

    Bus interface for climatic

    regulators for boilers in cascade

    Bus interface for climatic

    regulators for boilers in cascade

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    19/38153

    Solutions for centralized heating systems installations

    Single installation schemes

    Manometro

    bar

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    20

    40

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    20

    40

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    20

    40

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    20

    40

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    20

    40

    80100

    T E R M O M E T R O

    C

    QAD

    Manometro

    mmH2O

    mbar

    OCI420

    2

    4

    10

    7

    8

    9

    10

    1

    3

    5

    6

    SYSTEMMA

    DEOF1HIGHOUTPUTCON

    DENSINGBOILERPOWERH

    T,1DIRECTHIGHTEMPERA

    TURE

    CIRCUIT,1LOWT

    EMPERATUREMIXING

    CIRCUIT,1TANKFORTHESOLARINTEGRATION(OPTIO

    N)

    1HighoutputfloorstandingcondensingboilerPOWERHT

    2Safetydevice

    ISPESL(availableasoptional)

    3Reductionkit

    100/110

    4Hydraulicsep

    arator

    5Outdoorsensor

    6Interfaceform

    ixingsystemswithtwodifferenttemperatureszones

    7Flow/returnse

    nsor

    8DHWsensor

    9Doublecoilstoragetank(DC)forintegrationwithsolarsystems(option)

    10Thermostaticmixer

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    20/38154

    Single installation schemes

    DN50

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0 1 0 0

    T E R M O M E T R O

    C

    ECO

    QAD

    QAD

    RVA46

    M/B1

    MB/DB Y1/Y2

    Q2

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    Allo

    scar

    ico

    AlleUtenze

    All'impiantodiRiscaldamento

    MB-DB

    RVA46

    M/B1

    MB/DB Y1/Y2

    Q2

    OCI420

    Manometro

    mmH2O

    mbar

    7

    9

    12

    13

    15

    14

    2

    3 1

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C 6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C 6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C 6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    4

    6

    8 10

    11

    5

    1Highoutputf

    loorstandingcondensingboilerPOWER

    HT

    2Manifoldpipe

    ssingleboiler

    3Fumesmanifoldforsingleboiler

    4SafetydeviceISPESL(availableasoptional)

    5Interfaceformixingsystemswithtwodifferenttempe

    ratureszones

    6Hydraulicseparator

    7PipeintankcylinderUBPT1000

    8DHWsensor

    9Climaticregu

    latorformixedsystem

    10Tanksensor

    11Circulatinggroup

    12Solarcontro

    llerECO

    13Automatica

    ir-vent

    14Solarcollec

    torsSB25+V

    15Collectorss

    ensor

    SYSTEMM

    ADEOF1HIGHOUTPUTCO

    NDENSINGBOILERPOWER

    HT,

    1PIPEINTANKCYLINDE

    RFORHEATINGAND

    DHW

    PRODUCTIONINTEGRATION

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    21/38155

    Solutions for centralized heating systems installations

    Single installation schemes

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    QAZ21

    Manometro

    mmH2O

    mbar

    1

    2

    4

    3

    6

    7

    8

    5

    1

    Highoutpu

    tfloorstandingcondensingboilerPOW

    ERHT

    2

    Manifoldpipessingleboiler

    3

    Fluetubes

    forsingleboiler

    4

    Hydraulicseparator

    5

    Outdoorse

    nsor

    6

    DHWsens

    or

    7

    Singlecoil

    SCtank

    8

    Safetydev

    iceISPESL(availableasoptional)

    SYSTEMM

    ADEOF1HIGHOUTPUTCO

    NDENSINGBOILERPOWER

    HT,1HIGHTEMPERATUREDIRECTCIRCUIT,1TANK

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    22/38156

    Single installation schemes

    M a n o m e t r o

    b a r

    60

    0

    120

    2040

    80 1

    00

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    20

    40

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    60

    0

    120

    2040

    80100

    T E R M O M E T R O

    C

    QAZ21

    QAD

    ECO

    Manometro

    mmH2O

    mbar

    AGU

    2.

    500

    2

    6

    3

    5

    1

    12

    13

    8

    9

    10

    11

    14

    4Flat

    sola

    rcol

    lect

    ors

    Flat

    sola

    rcol

    lect

    ors

    1HighoutputfloorstandingcondensingboilerPOWERHT

    2Manifoldpipessing

    leboiler

    3Fumesmanifoldforsingleboiler

    4Interfaceformixing

    systemswithtwodifferent

    temperatureszones

    5SafetydeviceISPE

    SL(availableasoptional)

    6Hydraulicseparator

    7Outdoorsensor

    8DHWsensor

    9Solarcirculatinggroup

    10SolarcontrollerE

    CO

    11Doublecoilstorag

    etank(DC)

    12SolarcollectorsSB25+V

    13Collectorssensor

    14Tanksensor

    SYSTE

    MMADEOF1HIGHEFFICIE

    NCYCONDENSINGBOILER

    POWERHT,1HIGHTEMPER

    ATUREDIRECTCIRCUIT,

    1MIXI

    NGCIRCUIT,1TANKWITHIN

    TEGRATIONWITHSOLARSYSTEM

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    23/38157

    Solutions for centralized heating systems installations

    450 450 450

    2020

    936,5

    436,5

    186,5

    800

    136,5

    Dimensions

    The distance between the boilers in cascade varies from 450 mm to 20 mm depending on manifold accessory used.Flow/return manifolds squared 100x100 with anges DN80 PN6

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    24/38158

    with Power HT boilers from 45 to 150 kWCascade installation

    Shutter kit with condensing trapFrom 110 to 110

    Boiler-manifold pipe hydraulicconnection

    Hydraulic connectionfor 2ndpump

    Safety valve

    Non-return valve

    Shut-off valve

    Flue pipe kit for two boilersFrom 160 to 200

    Flow manifold

    Return manifold

    Flue pipe kit for the third boilerFrom 160 to 200

    Manifold pipes singleboiler/last boiler

    Manifold pipesboilers in cascade

    3 way shut-offvalve

    ReductionFrom 110 to 100

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    25/38159

    Solutions for centralized heating systems installations

    Cascade installations

    Manifold pipes single boiler/last boilerPower HT models Code Kit made of:

    45-150 kW KHW 714104210 . Flow manifold

    Return manifold

    Boiler-manifold pipe hydraulic connection

    Power HT models Code Kit made of:

    45-150 kW KHW 714104311 .

    2 way shut-off valve om returnCirculating pump UPS 32/80Non-return valveExtension vessel hydraulic connection3 way shut-off valve on ow

    Hydraulic connection for 2nd pump

    Power HT models Code Kit made of:

    45-150 kW KHW 714098611 .

    2 way shut-off valve UPS32/80 circulating pump Non-return valve Hydraulic joints

    Manifold pipes boilers in cascade

    Power HT models Code Kit made of:

    45-150 kW(45 cm between the boilers)

    KHW 714099010 . Flow manifold Return manifold

    45-150 kW(2 cm between the boilers)

    KHW 714103611 . Flow manifold Return manifold

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    26/38160

    Distance of the manifold from the rst boiler to the vertical chimney: 2 meters

    Shutter kit installed in each boiler in cascade

    The ue pipes and the connections between the ue manifold of the cascade and the chimney are not supplied by BAXI The manifolds in cascade over 200mm diameter are not supplied by BAXI

    The calculation has been made assuming a PP "double wall" ue duct

    The chart in the following page indicates the diameters of the flue manifold and of the chimney for various configurations of boi-

    lers in cascade and for different heights of the chimney.

    2 m

    A

    B

    H

    Remarks

    Information for the calculation of the diameter of the

    ue manifold (A) and the chimney (B)

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    27/38161

    Solutions for centralized heating systems installations

    N of boilers

    in cascadeHT

    1.450

    HT

    1.650

    HT

    1.850

    HT

    1.1000

    HT

    1.1200

    HT

    1.1500

    2 Nominal outputTotal 80/60 C (kW)

    90 130 170 200 240 300

    Flue manifold mm (A) 125 125 160 160 160 160

    Flue mm (B) -H= 5-10 m 125 125 160 160 160 200

    Flue mm (B) -H=10-15 m 125 125 160 160 200 200

    Flue mm (B) -H=15-20 m 125 125 160 160 200 200

    3 Nominal outputTotal 80/60 C (kW)

    135 195 255 300 360 450

    Flue manifold mm (A) 125 125 160 160 200 200

    Flue mm (B) -H= 5-10 m 125 160 160 160 200 200

    Flue mm (B) -H=10-15 m 125 160 160 160 200 200

    Flue mm (B) -H=15-20 m 125 160 160 160 200 250

    4

    Nominal output

    Total 80/60 C (kW)180 260 340 400 480 600

    Flue manifold mm (A) 125 160 160 160 200 200

    Flue mm (B) -H= 5-10 m 160 160 160 200 200 250

    Flue mm (B) -H=10-15 m 160 160 200 200 200 250

    Flue mm (B) -H=15-20 m 160 160 200 200 200 300

    5 Nominal outputTotal 80/60 C (kW)

    225 325 425 500 600 750

    Flue manifold mm (A) 160 200 160 200 200 250

    Flue mm (B) -H= 5-10 m 160 200 200 200 250 250

    Flue mm (B) -H=10-15 m 160 200 200 200 250 300

    Flue mm (B) -H=15-20 m 160 200 200 200 250 300

    Information for the calculation of the diameterof the flue manifold (A) and the chimney (B)

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    28/38162

    Controller - bus interface connection

    Bus interface is an electronic device that allows data exchange by bus between the PCB and the temperature regulator.

    After removing the cover of the control panel, mount the plate (B) supplied with the bus interface, and so mount the accessory as

    well (C). The at cable (A) have to be linked to the connector X40 of the electronics of the boiler. Connect the wiring (respecting

    the polarity) between the connector X41 of the bus interface and the connector MB-DB of the controller.

    Note: to make the connection easy between the accessory and the PCB, connect the wiring (A) to the PCB before xing the plate

    (B). To allow the mounting of the cover of the control panel it is necessary to cut the two plastic pins which are on the cover just

    next to the bus interface.

    Bus interface for climatic

    regulators for boilers in cascade

    Bus interface for climatic

    regulators for boilers in cascade

    l

    l l

    Bus interface for climatic

    regulators for boilers in cascade

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    29/38163

    Solutions for centralized heating systems installations

    Temperature regulator for boilers in cascade

    TEMPERATURE

    REGULATORFOR BOILERS

    IN CASCADE

    Pump of the tank

    Room thermostat

    Return sensor

    Flow sensor

    BUS INTERFACE FOR

    BOILERS IN CASCADE

    LINE

    ENGINE

    Back view

    Storage tank sensorPump of the heating

    system

    Power 230V AC

    Temperature regulator for cascade systems, allows up to 12 boilers connection ensuring functioning and

    efciency optimization. It manages a high temperature zone and pump, and a storage tank.

    It manages in the best way the boilers in cascade caring the modulation of the outputs and turning the

    time for switching-on to make the functioning timing of the various boilers in cascade uniform.

    The managing has this functioning: in case of need of heat the regulator will switch-on the rst boiler

    increasing the power slowly. If the output is still not sufcient to satisfy the need, it will switch the second

    boiler on, that together with the rst, will repeat the increase of the output.

    The cycle will be repeated for each single new switching-on of the boiler and in case of reduction of the heat load, the cycle will

    be made in the opposite way.

    The aim is to optimize the functioning of the system. This climatic regulator has the availability to manage 1 zone of the high

    temperature system, a pump and DHW. The regulator manages up 12 boilers in cascade, each one supplied with bus interface

    for boilers in cascade and 2 mixing zones controllers.N.B. accessory that can be used only with bus interface for boilers in cascade and outdoor sensor.

    Supplying: Temperature regulator for boilers in cascade+or/return sensor for boilers in cascade+connectors (KHG 714078212 .)

    Connections of the climatic regulator for boilers in cascade

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    30/38164

    Cascade installation schemes

    Manometro

    mmH2O

    mbar

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    QAD

    RVA47

    M/B70

    MB/DB

    M/B10

    Q1

    M/B3

    Q3

    QAD

    OCI420

    OCI420

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    6 0

    0

    1 2 0

    2 0 4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    QAZ21

    CONT1

    CONT2

    CONT1

    CONT2

    CONT1

    CONT2

    CONT1

    CONT2

    CONT1

    CONT2

    CONT1

    CONT2

    CONT1

    CONT2

    CONT1

    CONT2

    7

    2

    10

    12

    13

    9

    3

    6

    14

    10

    1

    8

    1

    1

    14

    14

    14

    14

    14

    14

    14

    5

    4

    SYST

    EMMADEOF2HIGHOUTPUTCONDENSINGBOILERSP

    OWERHT,1HIGHTEMPERA

    TUREDIRECTCIRCUIT,

    1TAN

    KWITHINTEGRATIONWITH

    SOLARSYSTEM(OPTION),

    BUILT-INHEATBOXESRH+2

    C

    1HighoutputfloorstandingcondensingboilerPOWE

    RHT

    2Safetydevice

    ISPESL(availableasoptional)

    3Fumesmanifoldtwoboilersincascade

    4Shutterkit

    5Reductionkit

    100/110

    6Hydraulicsep

    arator

    7Outdoorsens

    or

    8Businterface

    forclimaticregulatorsforboilersincascade

    9Climaticregu

    latorforboilersincascade

    10Floworretu

    rnsensorforcontrollerforboilers

    incascadeandmixingsystem

    11DHWsenso

    rformixingzones

    12Doublecoiltank(DC)forintegrationwith

    solarsystem

    s(option)

    13Thermostaticmixer

    14Built-inheat

    boxesRH+2C

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    31/38165

    Solutions for centralized heating systems installations

    Cascade installation schemes

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    QAD

    QAZ21

    RVA

    47

    M/B70

    MB/DB

    M/B10

    Q1

    M/B3

    Q3

    Manometro

    mmH2O

    mbar

    QAD

    OCI420

    OCI420

    1

    2

    74

    3

    5

    8

    10

    11

    12

    6

    9

    1HighoutputfloorstandingcondensingboilerPO

    WERHT

    2Manifold

    pipestwoboilersincascade

    3Fumesm

    anifoldtwoboilersincascade

    4Shutterk

    it

    5Hydraulicseparator

    6Outdoor

    sensor

    7Businterfaceforclimaticregulatorsforboilersincascade

    8Climatic

    regulatorforboilersincascade

    9Floworr

    eturnsensorforcontrollerforboilersin

    cascadeandmixingsystem

    10DHWsensorformixingzones

    11Double

    coiltank(DC)forintegrationwithsolarsystems(option)

    12SafetydeviceISPESL(availableasoptional)

    SYSTEM

    MADEOF2HIGHOUTPUT

    CONDENSINGBOILERSPOW

    ERHT,1HIGHTEMPERATU

    REDIRECTCIRCUIT,

    1TANK

    WITHINTEGRATIONWITHSOLARSYSTEM(OPTION)

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    32/38166

    Cascade installation schemes

    Manometro

    mmH2O

    mbar

    M a n o m e t r o

    b a r

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    QAD

    RVA47

    RVA46

    M/B70

    MB/DB

    MB/DB

    M/B10

    Q1

    M/B3

    Q3

    QAD

    M/B1

    Q2

    Y1/Y2

    QAD

    OCI420

    OCI420

    OCI420

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    M a n o m e t r o

    b a r

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    QAD

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    T E R M O M E T R O

    C

    QAZ21

    RVA46

    M/B1

    Q2

    Y1/Y2

    1

    12

    12

    15

    3 5

    5

    4

    5

    6

    6

    6

    7

    8

    9

    9

    9

    2

    11

    10

    11

    12

    12

    13

    14

    SYSTEM

    MADEOF3HIGHOUTPUTC

    ONDENSINGBOILERSPOW

    ERHT,2HIGHTEMPERATUR

    EDIRECTCIRCUITS,

    1TANKW

    ITHINTEGRATIONWITHSO

    LARSYSTEM(OPTION)

    1HighoutputfloorstandingcondensingboilerPOWE

    RHT

    2Safetydevice

    ISPESL(availableasoptional)

    3Fumesmanifoldtwoboilersincascade

    4Fumesmanifoldforthethirdboiler

    5Shutterkit

    6Reductionkit

    100/110

    7Hydraulicsep

    arator

    8Outdoorsens

    or

    9Businterface

    forclimaticregulatorsforboilersincascade

    10Climaticreg

    ulatorforboilersincascade

    11Climaticregulatorformixingsystem

    12Floworretu

    rnsensorforcontrollerforboilersinca

    scadeandmixingsystem

    13DHWsenso

    rformixingzones

    14Doublecoiltank(DC)forintegrationwithsolarsys

    tems(option)

    15Thermostaticmixer

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    33/38167

    Solutions for centralized heating systems installations

    Cascade installation schemes

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    QAD

    RVA47

    M/B70

    MB/DB

    M/B10

    Q1

    Manometro

    bar

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    6 0

    0

    1 2 0

    2 0

    4 0

    8 0

    1 0 0

    TERMOMETRO

    C

    Manometro

    bar

    Manometro

    mmH2O

    mbar

    QAD

    OCI420

    OCI420

    OCI420

    7

    1

    2

    6

    3

    5

    8

    4

    10

    10

    10

    10

    10

    10

    10

    10

    11

    9

    1HighoutputfloorstandingcondensingboilersP

    OWERHT

    2Manifoldpipestwoboilersincascade

    3Fumes

    manifoldtwoboilersincascade

    4Fumes

    manifoldforthethirdboiler

    5Shutterkit

    6Hydrau

    licseparator

    7Busint

    erfaceforclimaticregulatorsforboilersincascade

    8Climaticregulatorforboilersincascade

    9Floworreturnsensorforcontrollerforboilersin

    cascadeandmixingsystem

    10Built-inheatboxesLUNASATRS2Z

    11SafetydeviceISPESL(availableasoptional)

    SYST

    EMMADEOF3HIGHOUTPUTCONDENSINGBOILERSPOWERHT,1HIGHTEMPERATUREDIRECT

    CIRCUIT,

    BUILT

    -INHEATBOXESRS2Z

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    34/38168

    300

    811

    203

    157,5230

    330

    1069

    143

    Hydraulic separator HS 8,5 da 8,5m3/h 2 traded jointsWeight Kg 11,8 - Cod. LSD 790000310 .

    Hydraulic separator HS 18 da 18m3/h anged joints 65PN 16. Weight Kg 39 - Cod. LSD 790000320 .

    Maximum condensate water ow l/h 56

    Max potentiality of the boiler kcal/h da 201.000 a 300.000

    Max potentiality of the boiler kW 234-349

    Maximum working pressure bar 2

    Maximum temperature of the water content C Corresponding to the maximumtemperature of the condensate waters

    Min/Max room temperature C 5-40

    Quantity of the rst charge of product Kg 5

    Next recharges Kg 4,5

    Dimensions (hxwxd) mm 260x330x225

    Neutralizer lter to process the water deriving from the condensation of BAXI condensing boilers in cascade installations Cod.KHG 714125710 . To install the neutralizer kit it is necessary to install Power HT at least at 12 cm from the oor.Recharge for the neutralizer kit (output up to 350 kW) Cod. KHG 714135410 .

    For the theoretical explanation of the hydraulic separator see pages from 73 to 77

    264,5

    450

    1279

    95

    Hydraulic separator HS 28 da 28m3/h anged joints 80PN 16. Weight Kg 51 - Cod. LSD 790000330 .

    Hydraulic separator HS 56 da 56m3/h anged joints 100PN 16. Weight Kg 55 - Cod. LSD 790000340 .

    263

    450

    1279

    95

    Hydraulic separator

    Condensate neutralizer kit

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    35/38169

    Solutions for centralized heating systems installations

    Other accessories

    Other accessories

    Flue accessories for Power HT cascade installation

    Flue accessories for Power HT 45-65 kW cascade installation

    Picture Description Code

    PP ue pipe kit for two boilers 160 710715201 .

    PP ue pipe kit for two boilers 200 710715601 .

    PP ue pipe kit for third boilers 160 710716301 .

    PP ue pipe kit for third boilers 200 710716401 .

    PP 90 bend 160 KHW 714097810 .

    PP 90 bend 200 KHW 714098210 .

    PP pipe extension 160 L=1000 KHW 714097710 .

    PP pipe extension 200 L=1000 KHW 714098110 .

    Picture Description Code

    PP ue pipe kit for two boilers 125 710716801 .

    PP ue pipe kit for two boilers 125 710717701 .

    PP shutter kit 80/110 with condensing trap 710682001 .

    PP 90 bend 125 KHG 714094410 .

    PP 45 bend 125 (pack of 2) KHG 714094510 .

    PP pipe extension 125 L=1000 KHG 714094610 .

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    36/38170

    Other accessoriesFlue accessories for Power HT 85-150 kW cascade installation

    Hydraulic accessories

    Hydraulic accessories

    Picture Description Code

    Manifold pipes single boiler/last boiler KHW 714104210 .

    Boiler - manifold pipe hydraulic connection KHW 714104311 .

    2ndpump hydraulic connection KHW 714098611 .

    Manifold pipes boiler in cascade(45 cm between the boilers)

    KHW 714099010 .

    Manifold pipes boiler in cascade(2 cm between the boilers)

    KHW 714103611 .

    for single installation

    for cascade installation

    Picture Description Code

    PP shutter kit 110/110 with condensing trap 710682101 .

    PP reduction kit 110/100 KHW 714096910 .

    Picture Description Code

    Manifold pipes single boiler/last boiler KHW 714104210 .

    Boiler - manifold pipe hydraulic connection KHW 714104311 .

    2nd

    pump hydraulic connection KHW 714098611 .

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    37/38171

    Solutions for centralized heating systems installations

    Other accessories

    Picture Description Code

    Room sensor: it can be installed only withclimatic regulator for mixing system

    KHG 714078410 .

    Installation box for RVA controllers KHG 714096610 .

    Motor for the mixing valve KHG 714078511 .

    Mixing valve G1 KHG 714078310 .

    Mixing valve G1/2 KHG 714078610 .

    Mixing valve G3/4 KHG 714078710 .

    Flow/return sensor for controller for boilers in

    cascade and mixing system KHG 714078810 .

    Flow sensor for clip-in module KHG 714078910 .

    Hot water temperature sensor for climaticregulator for boilers in cascade

    KHG 714079010 .

    Hot water temperature sensor KHG 714076810 .

    Thermoregulation

  • 7/17/2019 Calderas Baxi Power HT45-150 kW .PDF

    38/38