2.2" 56mm
7.5"190mm
1.5" 38mm
Updated 7.2021 1
Quickship Order Form Edgeless Cove
410 381 1497 inter-lux.com [email protected] reserves the right to make technical changes without notice.
Model Fixation Pattern Length PowerCRI/CCT
Driver4 Lens Finish Options
WG-EC RPT SPC PR PZ
A A x B A x B x C A x B x A x B
LMH XH
927 930 935 940
X S D010 L3DAE L3D0E DFPN
SSD (std)SDC
W (std) LEC REC LREC
Description Code Quanity
Complete Fixture QS-WG-EC-RPT-S-12’-M-930-D010-SSD-W 12’
Housings³ QS-WG-EC-8.5’ 2
Complete Fixture
Housings³
Ordering Instructions
1. Provide product code for each run using the guide below.
2. Calculate and price each run completing the Total column.
3. Provide quantity of 8.5 ft (102 inch) field-cuttable housings (joiners will be included).
4. Measure mounting surface for housing and gear tray length (see gear tray order forms).
5. Provide Customer PO with this order form.
n Housings ship within 1 week of order date
n Gear trays ship within 2 weeks of confirmed field measurements
n Terms: Invoiced upon final shipment + freight with approved credit
Measuring Instructions (housing + gear tray)
Gear Tray
Housing1 See page 8 for order code descriptions. 2 See page 9 for cutting instructions.3 Includes joining connection kit (WG-JOINER-EC-KIT).
4 Drivers provided:96W Drivers (S, D010, L3D0E)3 W/ft = (1) driver per 24’ of fixture6 W/ft = (1) driver per 12’ of fixture10 W/ft = (1) driver per 8’ of fixture
40W Drivers (L3DAE & DFPN)3 W/ft = (1) driver per 12’ of fixture6 W/ft = (1) driver per 6’ of fixture10 W/ft = (1) driver per 3’ of fixture
Project Name _________________________________
Fixture Type _________________________________
PO# _________________________________
“Raft”
inside corner
mounting surface mounting surface
mounting surface mounting surface
“Co�er”
outside corner
iii•OIIIII[)
section view
mou
nti
ng
surf
ace
Fixture Qty.
1
2
3
4
Overall Length ‘A’
5
Fixture Qty.
6
7
8
9
Overall Length ‘L1’
10
gear tray gear tray
housing housing
power feed entrance
control feed entrance
wall wall
Light Direction
4" blankgear tray
4" blankgear tray
Edgeless Cove Straight Run Gear Tray Order Form
2
Measuring Instructions (housing + gear tray)
“Raft”
. . . .
.
. . ..
iii•OIIIII[)
section viewinside corner
mounting surface mounting surface
mounting surface mounting surface
“Co�er”
outside corner
mou
nti
ng
surf
ace
Field measure for Gear Tray production.
Notes
• 50' maximum per power feed. Power feed drilled in field.
• 4" blank gear tray will not be illuminated and is int end ed to reducehot spot on the adjacent wall.
• All Gear Trays will be powered by integral drivers.
• A record drawing will be provided to show the intended layout designof these gear trays.
• A standard 4ft Gear Tray will be used at all locations where possiblewith odd" lengths comprising the remainder of each run.
• Please refer to Whitegoods Edgeless Cove Installation Instructions fordetailed information about the installation and wiring of this fixture.
Project Name
FixtureType
PO#
Mounting Surface
"A"
Wall- to -Wall
Mounting SurfaceMounting Surface
Outside Corners (Raft)
90 deg. outside corner ‘raft’
housing housing housing
gear tray gear tray gear tray
wall
power feed entrance
control feed�entrance
wal
l
gear
tray
gear
tray
gear
tray
hous
ing
hous
ing
hous
ing
stra
ight
sec
tions
straight sections
Light Direction
Light Direction
4" blankgear tray
4" blank gear tray
Edgeless Cove Outside Corners (Raft)Gear Tray Order Form
3
1
2
3
Wall -to -Wall
Field measure for Gear Tray production.
Notes
Fixture Qty. Mounting Surface Length
‘A’ ‘B’
Mounting Surface
'A'
Mounting Surface
'B'
Project Name
FixtureType
PO#• 50' maximum per power feed. Power feed drilled in field.
• 4" blank gear tray will not be illuminated and is int end ed to reducehot spot on the adjacent wall.
• All Gear Trays will be powered by integral drivers.
• A record drawing will be provided to show the intended layout designof these gear trays.
• A standard 4ft Gear Tray will be used at all locations where possiblewith odd" lengths comprising the remainder of each run.
• Please refer to Whitegoods Edgeless Cove Installation Instructions fordetailed information about the installation and wiring of this fixture.
Mounting Surface Mounting Surface
1
2
3
4
Inside Corners (Coffer)
gear tray gear tray
housing
Wall-to -Wall
wall
housing housing
90 deg. inside corner
straight sections
control feed entrance
power feed entrance
wal
l
gear
tray
ge
ar tr
ay
hous
ing
hous
ing
hous
ing
stra
ight
sec
tions
Light Direction
4" blank gear tray
4" blank gear tray
4
Edgeless Cove Inside Corners (Coffer) Gear Tray Order Form
Field measure for Gear Tray production.
Notes
Fixture Qty. Mounting Surface Length
‘A’ ‘B’
Project Name
FixtureType
PO#
Mounting Surface
'A'
Mounting Surface
'B'
• 50' maximum per power feed. Power feed drilled in field.
• 4" blank gear tray will not be illuminated and is int end ed to reducehot spot on the adjacent wall.
• All Gear Trays will be powered by integral drivers.
• A record drawing will be provided to show the intended layout designof these gear trays.
• A standard 4ft Gear Tray will be used at all locations where possiblewith odd" lengths comprising the remainder of each run.
• Please refer to Whitegoods Edgeless Cove Installation Instructions fordetailed information about the installation and wiring of this fixture.
gear tray
gear
tray
Fixture Qty. Mounting Surface Length
1
2
3
4
‘A’ ‘B’
90 deg.90 deg. outside corner ‘raft’
Wall -to -Wall outside corner ‘raft’
housing housing housing
gear tray gear t ray gear tray
wall
control feed.entrance
power feed entrance
stra
ight
sec
tions
hous
ing
hous
ing
hous
ing
gear
tray
gear
tray
gear
tray
wal
l
gear
tray
gear
tray
gear
tray
KR
XV
LQJ
hous
ing
hous
ing
stra
ight
sec
tions
Light Direction
Light Direction
Light Direction
4" blank gear tray
4" blank gear tray
‘C’
Mounting SurfaceMounting Surface
Outside Corners (Raft)
5
Edgeless Cove Outside Corners (Raft) Gear Tray Order Form
Field measure for Gear Tray production.
Notes
Project Name
FixtureType
PO#
Mounting Surface
'A'
Mounting Surface
'B'
Mounting Surface
'C'
• 50' maximum per power feed. Power feed drilled in field.
• 4" blank gear tray will not be illuminated and is int end ed toreduce hot spot on the adjacent wall.
• All Gear Trays will be powered by integral drivers.
• A record drawing will be provided to show the intended layout design of these gear trays.
• A standard 4ft Gear Tray will be used at all locations wherepossible with odd" lengths comprising the remainder ofeach run.
• Please refer to Whitegoods Edgeless Cove InstallationInstructions for detailed information about the installationand wiring of this fixture.
gear tray
housing
gear tray
housing
gear tray
housing
gear
tra
y
hou
sin
g h
ousi
ng
stra
igh
t se
ctio
ns
gear
tra
y
hou
sin
g
gear
tra
y
gear
tra
y
hou
sin
g
gear
tra
y
hou
sin
g
gear
tra
y
hou
sin
g
90 deg.outside corner‘raft’
gear tray
housing
gear tray
housing
gear tray
housing
straight sections
stra
igh
t se
ctio
ns
straight sections
90 deg.outside corner‘raft’
90 deg.outside corner‘raft’
90 deg.outside corner‘raft’
wall
wall
wal
l
wal
l
Mounting SurfaceMounting Surface
Outside Corners (Raft)
control feed.entrance
power feed entrance
6
1
2
3
4
Edgeless Cove Outside Corners (Raft) Gear Tray Order Form
Field measure for Gear Tray production.
Notes
Fixture Qty. Mounting Surface Length
‘A’ ‘B’
Project Name
FixtureType
PO#
Mounting Surface
'A'
Mounting Surface
'B'
• 50' maximum per power feed. Power feed drilled in field.
• 4" blank gear tray will not be illuminated and is int end ed to reducehot spot on the adjacent wall.
• All Gear Trays will be powered by integral drivers.
• A record drawing will be provided to show the intended layout designof these gear trays.
• A standard 4ft Gear Tray will be used at all locations where possiblewith odd" lengths comprising the remainder of each run.
• Please refer to Whitegoods Edgeless Cove Installation Instructions fordetailed information about the installation and wiring of this fixture.
Mounting Surface Mounting Surface
gear
tra
y
hou
sin
g h
ousi
ng
gear
tra
y
hou
sin
g
gear
tra
y
straight sections
stra
igh
t se
ctio
ns
90 deg.inside corner
straight section
s
gear tray
housing
gear tray
hou
sing
gear tray
hou
sing
gear tray
hou
sing
housing
gear traygear tray
housing
straight sections
gear tray
housing
gear tray
housing
wall
wall
wal
l
wal
l
power feedentrance**
power feedentrance**
Inside Corners (Coffer)
control feed.entrance
power feed entrance
7
1
2
3
4
Fixture Qty. Mounting Surface Length
‘A’ ‘B’
Edgeless Cove Inside Corners (Coffer)Gear Tray Order Form
Field measure for Gear Tray production.
NotesProject Name
FixtureType
PO#
Mounting Surface
'A'
Mounting Surface
'B'
• 50' maximum per power feed. Power feed drilled in field.
• 4" blank gear tray will not be illuminated and is int end ed to reducehot spot on the adjacent wall.
• All Gear Trays will be powered by integral drivers.
• A record drawing will be provided to show the intended layout designof these gear trays.
• A standard 4ft Gear Tray will be used at all locations where possiblewith odd" lengths comprising the remainder of each run.
• Please refer to Whitegoods Edgeless Cove Installation Instructions fordetailed information about the installation and wiring of this fixture.
2.2" 56mm
7.5"190mm
1.5" 38mm
(930-20174-REV.E) 8
Edgeless Cove
410 381 1497 inter-lux.com [email protected] reserves the right to make technical changes without notice.
Ordering Information
WG-EC RPT
Model Fixation Pattern Length Power3 CRI/CCT4 Driver5 Lens Finish Options6
WG-EC RPT S1
PC2 PR2 PZ2
A A x B A x B x C A x B x A x B
LMH XH
927 930 935 940
X S D010 L3DAE L3D0E DFPN
SSD (std)SDC
W (std) F
LEC REC LREC LWR RWR
Luminairen Light source positioned for optimum
horizontal spread of illumination.n Light source is not visible from any
viewing angle up to and including direct horizontal view.
n Delivers continuous soft wash of directed light to above surface.
n Satin Diffu er for high efficie y and soft edge beam without striations.
n Removable light source sub assembly for simple installation and maintenance.
n High efficie y linear LED in a range of outputs.
n Integral drivers and through wiring.n Lengths and angles factory cut to exact field
dimensions.n Mitered corners available with continuous
illumination.
Fixationn RPT = Recessed plaster trim
Patternn S = Straight run1
n PC = Standard patterns coffer 2, 3 or 4 sided with 90° corners2
n PR = Standard patterns raft 2, 3 or 4 sided with 90° corners2
n PZ = Non-standard patterns and/or corners other than 90°, consult factory2
Lengthn A, B, C = specify inches to the nearest 0.25”
(i.e. 72.25”) For patterns specify each length (i.e. 2 sided: A x B = 72.25” x 48”; 3 sided: A x B x C; 4 sided: A x B x A x B)
Power3
n L = 3W/ft low power (24V)n M = 6W/ft medium power (24V)n H = 10W/ft high power (24V)n XH = 13W/ft extra high power (24V)
CRI/CCT4 90+ CRI minimum (Low/Mid/High/Extra High)n 927 = 2700K, (276/552/920/1196 lm/ft)n 930 = 3000K, (276/552/920/1196 lm/ft)n 935 = 3500K, (282/563/938/1220 lm/ft)n 940 = 4000K, (282/563/938/1220 lm/ft)
Driver (integral)5
n X = No driver, ordered separately n S = Standard driver 120-277Vn D010 = Osram, 10%, 0-10V dimming, 120-277Vn L3DAE = Lutron Hi-lume 1% EcoSystem,
120-277Vn L3D0E = Lutron Hi-lume Premier 0.1%
EcoSystem, 120-277V (remote)n DFPN = Lutron Forward Phase 1%, 120VAC
Lensn SSD = Snap On Satin Diffu er (standard)n SDC = Satin Clear Dust Cover
Finishn W = White, 15% gloss, RAL9010 (standard)n F = Custom finish specify RAL
Options6
n LEC = Left end capn REC = Right end capn LREC = Left & Right end capsn LWR = Left wall returnn RWR = Right wall return
Emergency Remote Onlyn Emergency LED battery backup available,
order separately.
1 Standard setup assumes the cove ends at a perpendicular wall and the LED board is setback from the end to minimize light on the perpendicular wall. Contact us for options.
2 See pattern specsheet.3 Wattage shown does not include power
supplies/drivers.4 Delivered lumens with snap on satin diffuser shown.5 Integral driver, except L3D0E (remote only). See power supply page for details.6 Order optional end caps when ends are vissible (Utility
end caps included).
Gypsum Ceiling Mounting 4" minimum offset, 12" typical offsetCan be installed in Cove or Coffer
12”
12”
12”
12”
*surface mount only
WG-EC-LEC Left End Cap*
WG-EC-REC: Right End Cap*
top view
WG-EC-LWR: Left End Wall Return*
top view
top view top view
WG-EC-RWR:Right End Wall Return*
wall
nose
wall
nose
wall
wallnose
wall
wall
wall
wall
nose
nose
nose
nose n
ose
5”
specify
specify
Custom Raft Angle
wall
specify
wall
specify
nose
nose
Custom Co’er Angle
Specify Degrees
Specify Degrees
90º90º
2 1/4” 2 1/4”
5”
5” 5”12”
WG-EC-C90R: Corner 90° Raftoutside corner
WG-EC-C90C: Corner 90° Co’erinside corner
12”
End Caps (Use when not installing wall to wall)
12”
12”
12”
12”
*surface mount only
WG-EC-LEC Left End Cap*
WG-EC-REC: Right End Cap*
top view
WG-EC-LWR: Left End Wall Return*
top view
top view top view
WG-EC-RWR:Right End Wall Return*
wall
nose
wall
nose
wall
wallnose
wall
wall
wall
wall
nose
nose
nose
nose n
ose
5”
specify
specify
Custom Raft Angle
wall
specify
wall
specify
nose
nose
Custom Co’er Angle
Specify Degrees
Specify Degrees
90º90º
2 1/4” 2 1/4”
5”
5” 5”12”
WG-EC-C90R: Corner 90° Raftoutside corner
WG-EC-C90C: Corner 90° Co’erinside corner
12”
Edgeless Cove Housing Field Cutting Instructions
Tools Required
· Measuring Tape or Laser Measurement Tool
· Saw—Compound Miter Saw w/8-10 Tooth per Inch, Bi-Metal BladeRecommended
· Adjustable Angle Measuring Tool of choice
Cuƫng Procedure
· Locate and measure the mounƟng surface for straight runs. MounƟng surface is defined above
· Using a saw as recommended above, make straight and clean cuts on all housings that will be joined with another
housing, or an end cap. All 102” material will need a finish cut, and is to have a clean edge that is free of paint.
· Clamping and support of the material while cuƫng should be as shown below. We recommend using a 1x4 support
under the extrusion to keep it square. This is especially important when cuƫng corners of any kind. Clamping to the
back side should be made in a way that is not obstrucƟng to the saw path or safety of the operator.
Housing InstallaƟon
· See complete Edgeless Cove InstallaƟon InstrucƟons.
Field Measurement for Gear Tray ProducƟon
· See Gear Tray Measurement InstrucƟons
The Whitegoods Edgeless Cove Housing can be field cut for straight, conƟnuous runs, as well as runs of product
with corners. Housings are provided in nominal 8’6” lengths and require a finish cut on both ends.
Do not aƩempt to align housings unless you have made a straight and smooth cut on the maƟng ends of each
housing, or those ends to have an end cap applied.