Page 1: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

L2+ Multi-Port Full Gigabit Managed Ethernet Switch

IGS-10020MT / IGS-10020PT / IGS-10020HPT /

IGS-10080MFT / IGS-20040MT

Quick Installation Guide

Page 2: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

Table of Contents

1. Package Contents ....................................................................................... 3

2. Requirements ............................................................................................. 4

3. Wiring the Power Inputs .............................................................................. 5

4. Terminal Setup ........................................................................................... 8

5. Logon to the Console .................................................................................. 9

6. ConfiguringIPaddress ...............................................................................10

7. Starting Web Management .........................................................................13

8. Resetting the Switch to Default ..................................................................16

9. Customer Support .....................................................................................18

Page 3: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

3

1. Package ContentsThank you for purchasing PLANET L2+ Industrial Managed Switch, IGS-10020Series / IGS-10080MFT / IGS-20040MT. The descriptions of these models are asfollows:

IGS-10020MT:Industrial8-Port10/100/1000T+2-Port100/1000XSFPManagedSwitch

IGS-10020PT:Industrial8-Port10/100/1000T802.3afPoE+2-Port100/1000XSFPManagedSwitch

IGS-10020HPT:Industrial8-Port10/100/1000T802.3af/atPoE+2-Port100/1000XSFPManagedSwitch

IGS-10080MFT:Industrial8-Port100/1000XSFP+2-Port10/100/1000TManagedSwitch

IGS-20040MT:Industrial16-Port10/100/1000T+4-Port100/1000XSFPManagedSwitch

“Industrial Managed Switch” mentioned in this Quick Installation Guide referstotheabovefivemodels.

Open the box of the Industrial Managed Switch and carefully unpack it. Theboxshouldcontainthefollowingitems:

z TheIndustrialManagedSwitchx1

z QuickInstallationGuidex1

z DIN Rail Kit x 1

z Wall Mounting Kit x 1

z DB9 to RJ45 Interface RS232 Console Cable x 1

(ForIGS-10020PT/IGS-10020HPT/IGS-10080MFT/IGS-20040MT)

z DustCap(Pleaserefertothetablebelow)

RJ45 Dust Cap SFP Dust Cap

IGS-10020MT 8 2

IGS-10020PT 9 2

IGS-10020HPT 9 2

IGS-10080MFT 3 8

IGS-20040MT 17 4

Page 4: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

4

Ifanyofthesearemissingordamaged,pleasecontactyourdealerimmediately.Ifpossible,retainthecartonincludingtheoriginalpackingmaterialstoenableyoutorepacktheproductincasethereisaneedtoreturnittousforrepair.

2. RequirementsThe Industrial Managed Switch provides remote login interface for managementpurposes. The following equipment is necessary for further management:

WorkstationisinstalledwithEthernetNIC(NetworkInterfaceCard)

Choiceof Internetbrowsers includesWindowsXP/2003,Vista,Windows7,MACOS X, Linux, Fedora, Ubuntu or other platforms compatible with TCP/IP proto-cols.

z The aboveworkstation is installedwithWebbrowser and JAVA runtimeenvi-ronmentplug-in.

Ethernet Port connection

z Usestandardnetwork(UTP)cableswithRJ45connectors.

Note

It is recommended touse InternetExplore7.0or above toaccesstheIndustrialManagedSwitch.

Page 5: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

5

3. Wiring the Power InputsThe Upper Panel of the Industrial Managed Switch indicates a DC inlet powersocketandconsistsofoneterminalblockconnectorwithin6contacts.Pleasefollowthe steps below to insert the power wire.

1.Insertpositive/negativeDCpowerwires intocontacts1and2 forPower1,or5,and6forPower2.

IGS-10020MT: DC 12~48V, AC 24V

InputDC 12V~48V, AC 24V

V1- V1+

PWR1

V2- V2+

PWR2Fault

Figure 3-1: IGS-10020MT Upper Panel

IGS-10020PT / IGS-10020HPT: DC 48V

Figure 3-2: IGS-10020PT / IGS-10020HPT Upper Panel

Page 6: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

6

IGS-10080MFT: DC 12~48V, AC 24V

Input DC 12V~48V

V1- V1+V2- V2+

PWR1PWR2 Fault

1A@24V

Figure 3-3: IGS-10080MFT Upper Panel

IGS-20040MT: DC 12~48V, AC 24V

Input DC 12-48V AC 24V

DC1 DC2Fault

DI 0 DI 1 DO 0 DO 1 GND GND

Figure 3-4: IGS-20040MT Upper Panel

Page 7: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

7

Tightenthewire-clampscrewsforpreventingthewiresfromloosening.

1 2 3 4 5 6Power 1 Power 2+ - + -

Note

Thewiregauge for the terminalblockshouldbe in therange from12to24AWG.

Page 8: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

8

4. Terminal SetupToconfigurethesystem,connectaserialcabletoaCOMportonaPCornotebookcomputerandtoRJ45typeserial (console)portof theManagedIndustrialSwitch.TheconsoleportoftheIndustrialManagedSwitch isDCEalready,sothatyoucanconnecttheconsoleportdirectlythroughPCwithouttheneedofnullmodem.

PC / Workstationwith

Terminal emulation software

RJ45 to DB9 RS-232 CableSerial Port

IP Address:192.168.0.100

IGS Industrial Managed Switch

A terminal program is required to make the software connected to the IGSIndustrial Managed Switch. Windows’ Hyper Terminal program may be a goodchoice.TheHyperTerminalcanbeaccessedfromtheStartmenu.

1. Click START,thenPrograms, AccessoriesandthenHyper Terminal.

2.When the following screen appears, make sure that the COM port should beconfiguredas:

Baud :115200

Parity : None

Data bits : 8

Stop bits : 1

FlowControl :None

Page 9: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

9

5. Logon to the ConsoleOnce the terminal has been connected to the device, power on the IndustrialManagedSwitchandtheterminalwilldisplay“runningtestingprocedures”.

Note

1.TherearefourswitcheswithRJ45typeconsoleconnector.(IGS-10020PT/IGS-10020HPT/IGS-10080MFT/IGS-20040MT)

2.Let’stakeIGS-20040MTforexample.

When the following dialog box shown in Figure 5-1 appears, please enter thefactorydefaultusername“admin” andpassword“admin”.

Username:adminPassword:admin

Figure 5-1: Console Login screen

Note

1.Forsecurityreason,pleasechangeandmemorizethenewpass-wordafterthisfirstsetup.

2.Only accept command in lowercase letter under console inter-face.

Page 10: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

10

6.ConfiguringIPaddressTheIndustrialManagedSwitchisshippedwithdefaultIPaddressshownbelow:

IPAddress:192.168.0.100Subnet Mask: 255.255.255.0

TocheckthecurrentIPaddressormodifyanewIPaddressfortheSwitch,pleaseusetheproceduresasfollows:

Display of the current IP Address1. At the “#”prompt,enter“show ip interface brief”.

2.ThescreendisplaysthecurrentIPaddressshowninFigure5-1.

Figure 6-1: IP Information Screen

Page 11: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

11

Configuration of the IP Address3. At the “#”prompt,enterthefollowingcommandandpress<Enter> as shown inFigure5-2.

IGS-20040MT# configure terminalIGS-20040MT(config)# interface vlan 1IGS-20040MT(config-if-vlan)# ip address 192.168.1.100 255.255.255.0

The previous command would apply the following settings for the IndustrialManagedSwitch.

IPAddress:192.168.1.100Subnet Mask: 255.255.255.0

Figure 6-2: Configuring IP Address Screen

4.Repeatstep1tocheckiftheIPaddressischanged.

Page 12: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

12

Store the current switch configuration5. At the “#”prompt,enterthefollowingcommandandpress<Enter>.

# copy running-config startup-config

Figure 6-3: Saving Current Configuration Command Screen

If the IP is successfully configured, the Industrial Managed Switch will apply thenew IP address setting immediately. You can access the Web interface of theIndustrialManagedSwitchthroughthenewIPaddress.

Note

If you are not familiar with the console command or the relatedparameter, enter “help” anytime in console to get the help description.

Page 13: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

13

7. Starting Web ManagementThe following shows how to start up the Web Management of the IndustrialManaged Switch. Note the Industrial Managed Switch is configured through anEthernet connection. Please make sure the manager PC must be set on the same IPsubnetaddress.

For example, the default IP address of the Industrial Managed Switch is192.168.0.100, then the manager PC should be set at 192.168.0.x (where xis a number between 1 and 254, except 100), and the default subnet mask is255.255.255.0.

IP Address:192.168.0.x IP Address:

192.168.0.100

IGS Industrial Switch

RJ45/UTP-Cable

Figure 7-1: IP Management Diagram

Logging in the Industrial Managed Switch1.Use Internet Explorer 7.0 or above for Web browser and enter IP address

http://192.168.0.100 (the factory-default IP address) to access the Webinterface.

2.When the following dialog box appears, please enter the default user name“admin”andpassword“admin”(orthepasswordyouhavechangedbefore)asshowninFigure7-2.

DefaultIPAddress:192.168.0.100DefaultUserName:adminDefaultPassword:admin

Page 14: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

14

Figure 7-2: Login Screen

3.Afterenteringthepassword,themainscreenappearsasshowninFigure7-3.

Figure 7-3: Web Main Screen of Industrial Managed Switch

Page 15: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

15

4. The Switch Menu on the left of the Web page lets you access all the functions andstatustheIndustrialManagedSwitchprovides.

Now, you can use the Web management interface to continue the Switchmanagement. Please refer to the user manual for more.

Note

For security reason, please change and memorize the new pass-wordafterthisfirstsetup.

Page 16: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

16

8. Resetting the Switch to Default To reset the IP address to the default IP Address “192.168.0.100” and theuser password to factory default mode (default password is admin), press thehardwareresetbuttononthefrontpanelforabout10seconds.Afterthedevice isrebooted,youcan loginthemanagementWeb interfacewithinthesamesubnetof192.168.0.xx and default password. Be noted that all the previous setupswill bedisappearedafterthefactorydefaultresetismade.

Mini-GBIC

100/1000X SFP

RESET

ACTLNK

109

P1 P2 FAULT

Ring R.O.

9

LNK/ACT1000LNK/ACT1000

10

ACTLNK

1000Reset Button

Figure 8-1: IGS-10020MT Reset Button

ACTLNK

IGS-10020HPT

9

LNK/ACT1000LNK/ACT1000

10

8

6

4

2

7

5

3

1

RESET

9

Console

115200,N,8,1

P1 P2

Ring R.O.

FAULT

10

100/1000X SFP

10/100/1000T

ACTLNK

PoE In-Use

802.3at PoE

Reset Button

Figure 8-2: IGS-10020PT / IGS-10020HPT Reset Button

Page 17: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

17

Reset Button

Figure 8-3: IGS-10080MFT Reset Button

1

3

5

2

4

6 17

RESET

Console

P1 P2

Ring R.O.

FAULT

Reset Button

Figure 8-4: IGS-20040MT Reset Button

Page 18: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT

18

9. Customer SupportThank you for purchasing PLANET products. You can browse our online FAQresourceonPLANETwebsitefirsttocheckif itcouldsolveyourissue.Ifyouneedmoresupportinformation,pleasecontactPLANETswitchsupportteam.

PLANETonlineFAQ:http://www.planet.com.tw/en/support/faq.php

Switchsupportteammailaddress:[email protected]

IGS-10020MT / IGS-10020PT / IGS-10020HPT / IGS-10080MFT / IGS-20040MTUser’sManual:

http://www.planet.com.tw/en/support/download.php?type1=22153&model=&type=3

(PleaseselectyourswitchmodelnamefromProductModeldropdownmenu)

Copyright © PLANET Technology Corp. 2014.Contents are subject to revision without prior notice.PLANET is a registered trademark of PLANET Technology Corp.All other trademarks belong to their respective owners.

Page 19: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT
Page 20: Quick Installation Guide - planet.com.tw · 9 10 P1 P2 FAULT Ring R.O. 9 1000 LNK/ACT 1000 LNK/ACT 10 LNK ACT 1000 Reset Button Figure 8-1: IGS-10020MT Reset Button ACT LNK IGS-10020HPT