QK-W015 series remote controller is a versatile device which can be attached to many ofelectronic devices in homes, offices, plants, or wherever you need. Operators can control anyremote equipments, heater, lights, machines, or power sockets from anywhere in the worldthrough internet. QK-W015 support three relay outs and 433MHz RF transmitter. RF powersockets within 50 meters of QK-W015 can be controlled by mobile operators.
Citation preview
Quark-Elec Application Note
http://www.quark-elec.com 1 of 13 2014
V1.1
QK-W015 WiFi Remote Controller Application Notes
Features Turn Electronics ON or OFF from anywhere through internet
Remote Control from 50 Meters with WiFi
Android, iOS App & Application for Windows platform
Instant Set Up
Up to 10 Mobiles Phones per Unit
Switching Electronics Devices through Relays or 433MHz RF Main Sockets
Master ON/OFF –Turn Everything on with One Click
Support both Ad-hoc and Station Mode
UK, Europe & USA RF Power Sockets Available
Applications
Control Lighting, Electrical Appliance
Smart House
Automation Application
Remote Maintenance
Irrigation Systems
Plant Maintenance
Valve Control
Quark-Elec Application Note
http://www.quark-elec.com 2 of 13 2014
V1.1
Pumping Station
Security Systems
PLC and Automation System
Document History
Issue Date Changes / Comments
1.0 12-10-2014 Initial release
1.1 02-12-2014 New hardware release
Order Information
Part No Description
QK-W015 WiFi Remote controller (only three relays output, no RF 433MHz module and RF plug sockets)
QK-W015UK QK-W015 with three RF 433MHz UK type main sockets
QK-W015EU QK-W015 with three RF 433MHz Europe type main sockets
QK-W015US QK-W015 with three RF 433MHz USA type main sockets
Contents
1 INTRODUCTION ................................................................................................................... 3
2 SETUP ................................................................................................................................... 3
2.1 POWER UP .......................................................................................................................... 3 2.2 ACCESS QK-W015 .............................................................................................................. 3
3 AD-HOC MODE ..................................................................................................................... 4
3.1 CONNECT WITH MOBILE PHONES.......................................................................................... 5 3.2 RENAME THE PORT .............................................................................................................. 6
4 STATION (INFRASTRUCTURE) MODE .............................................................................. 6
Quark-Elec Application Note
http://www.quark-elec.com 3 of 13 2014
V1.1
4.1 STATION MODE SETTING THROUGH APP ............................................................................... 7 4.2 SWITCHING TO STATION MODE .............................................................................................. 8 4.3 RESET................................................................................................................................. 9
5 PARING WITH RF POWER SOCKETS ................................................................................ 9
6 APP(ANDROID VERSION) ................................................................................................. 10
7 HARDWARE........................................................................................................................ 10
7.1 CONNECTIONS ................................................................................................................... 10 7.2 RF MAIN SOCKETS ............................................................................................................. 11 7.3 ENCLOSURE ...................................................................................................................... 12
8 OPERATING SPECIFICATIONS ........................................................................................ 12
1 INTRODUCTION
QK-W015 series remote controller is a versatile device which can be attached to many of
electronic devices in homes, offices, plants, or wherever you need. Operators can control any
remote equipments, heater, lights, machines, or power sockets from anywhere in the world
through internet. QK-W015 support three relay outs and 433MHz RF transmitter. RF power
sockets within 50 meters of QK-W015 can be controlled by mobile operators.
Figure 1 System diagram (Station mode)
2 SETUP
2.1 Power up
QK-W015 remote controller need to be powered by 12VDC voltage. Connect a 12 volt DC
power supply to the power socket, switch on the power supply. The blue LED should light
up and then flashing slowly. After about 10 seconds, the Red LED will light up indication
system finishes initialization.
2.2 Access QK-W015
After QK-W015 finish initialization, operator should be able to scan SSID on the mobile
terminals and find a SSID called ‘WiFi168’. Access WLAN of the mobile terminal and
connect with the ‘WiFi168’. The default password is ‘88888888’. Blue LED will keep light
up once the ‘WiFi168’ is connected by the operators mobile terminal. If ‘WiFi168’ cannot
Quark-Elec Application Note
http://www.quark-elec.com 4 of 13 2014
V1.1
be found, please go to ‘RESET’ section of this application note following the steps to reset
the module.
Figure 2 Search SSID
Figure 3 Connect to QK-W015
3 AD-HOC MODE
The IEEE 802.11 has two basic modes of operation: Ad-hoc mode and infrastructure
mode(also called station mode). In ad hoc mode, mobile terminals transmit directly peer-to-
peer. While In infrastructure mode, mobile terminals communicate through an access point(AP)
that serves as a bridge to other networks (such as Internet or LAN). QK-W015 WiFi controller
can support in both Ad-hoc and Station mode.
Setting QK-W015 works in Ad-hoc mode is quite straightforward. Once the mobile terminal
connected to WiFi168 network, QK-W015 then works in Ad-hoc automatically.
Quark-Elec Application Note
http://www.quark-elec.com 5 of 13 2014
V1.1
Figure 4 Working in Ad-hoc mode
Operator can use the following link to download the latest version of Android App to work with
QK-W015.
http://www.quark-elec.com/down/class/?3.html
Figure 5 Main page of APP
3.1 Connect With Mobile phones
Once the ‘WiFi168’ is connected, operators can control these electronics devices in
‘Main control panel’ which have connected on relays and RF main sockets. The
indicator icons (the light bulb next to ‘Off’ button) can demonstrator each relay.
Due to one way communication between QK-W015 and 433MHz RF main sockets,
the status of the RF main sockets cannot be check and indicated.
Quark-Elec Application Note
http://www.quark-elec.com 6 of 13 2014
V1.1
Figure 6 Indicator of the setting
3.2 Rename the port
Operators can rename the three relay outputs and three RF main sockets as meaningful names
through settings on App.
Figure 7 Rename the port
4 STATION (INFRASTRUCTURE) MODE
To control QK-W015 remotely, it should be set working in station mode, operator need perform
the following procedure to finish the setting.
1,Press and hold the ‘Reset’ button, then power up QK-W015. The blue LED will light up for few
seconds, then the red LED turns on. Keep the red LED turns on for 3 seconds, release
‘Reset ’button.
These icons indicate the
status of the relays.
Quark-Elec Application Note
http://www.quark-elec.com 7 of 13 2014
V1.1
2, Wait for 60 seconds, red LED turns off and then turns on again. During this period, blue LED
blinking every second interval.
3, Operator can now use the mobile terminal search and connect ‘WiFi168’.
4, Once this Ad-hoc connection has been setup, operator can start the following setting through
APP.
SSID name ---- Input the SSID name(or called AP name) which QK-W015 will access to.
Password --- Input the password for accessing AP. Quark-elec notices for some old type
Access Point, they maybe have connection problem with QK-W015 if the AP security type
set as ‘WEP’. So, if operator has the access problem, please change the security type to
‘WPA’ or ‘WPA2’, avoiding ‘WEP’ on the wireless router.
IP address --- Dynamic IP address will be assigned by QK-W015 if operator don’t set a
static IP address on APP.
5, Re-power up QK-W015 to apply the remote control function.
4.1 Station mode setting through APP
Operator should make sure QK-W015 has connected with the mobile terminal in ad-hoc
mode before the following setting. Run the APP, click ‘Station mode setting’, input SSID of
the AP and then ‘Save’. The red LED will turn off. Keep waiting until the response
message received from QK-W015. Then the same way applies for setting the password. It
is recommended that operator don’t set static IP address to QK-W015 if static IP address
has to be used.
Quark-Elec Application Note
http://www.quark-elec.com 8 of 13 2014
V1.1
Figure 8 Station mode setting
4.2 Switching to station mode
Once the above setting finished, operator can click ‘Switch to station mode’ to set QK-
W015 working in station mode.
After click ‘Switch to station mode’, the red LED light will turn off indicating system is busy.
Waiting about 90 seconds, the blue LED will turns off. Another 30 seconds, the red LED
light turn on firstly and then the blue LED. If the SSID or password is not correct, then the
blue LED will keep blink. In this case, operator should reset the module and repeat the
setting procedure again.
Once QK-W015 has successfully connected with the AP in station mode, operator should
re-power up QK-W015 to get the full function applied (don’t press the reset button during
the re-power process).
Quark-Elec Application Note
http://www.quark-elec.com 9 of 13 2014
V1.1
Figure 9 Switch to station mode
4.3 Reset
Operator can always reset QK-W015 if the setting is incorrect or would like to switch the working
mode. Following below steps to reset QK-W015 to the factory settings:
1, Power off QK-W015.
2, Press and hold the ‘Reset’ button, then power up QK-W015. Blue LED will light up for few
seconds, then the red LED turns on. Keep the red LED turns on for 3 seconds, release
‘Reset ’button.
3, Wait for 60 seconds, the red LED turns off and then turns on again. During this period, the
blue LED is blinking every second.
4, Operator can now available to connect to ‘WiFi168’.
5 PARING WITH RF POWER SOCKETS
QK-W015 has a build-in 433Mhz RF transmitter module. It can pair with up to four RF power
sockets. So the operators are able to turn ON/OFF the electrical devices by switching the
power sockets.
The power sockets have been paired and ready to use if they come with QK-W015. However
the operator can always pair or release the pairing by following steps:
Insert the RF power socket into a powered mains wall socket.
The LED light on the socket should flash at 1 second intervals indicating it’s ready to
pair with the QK-W015. If the lights doesn’t flash, press and hold the ON/OFF button for
5 seconds to clear the memory indicated by the quickly flashing LED.
Open WiFi Remote control panel in App, press the corresponding RF switch ‘ON’
button. The paring command will be sending out through RF signals.
Quark-Elec Application Note
http://www.quark-elec.com 10 of 13 2014
V1.1
Figure 10 RF Switch ON buttons
Once the power socket received the paring command, The LED light on the socket will
flash briefly more quickly and then flash at 1 second intervals. This RF main socket
should have been successfully paired now.
Repeat above process for each different RF main sockets.
Simply plug-in the appliance which you want to operate remotely into the socket, press the
corresponding ON button on App that is paired to the socket. The appliance will turn on.
6 APP(ANDROID VERSION)
The latest version of Android APP can be downloading with the following link:
http://www.quark-elec.com/down/class/?3.html
Once the mobile phone has connected with QK-W015, the operator can control
these electronics devices which connected on relays and RF main sockets. And the
operator can check the relays status by click ‘Check relays status’.
7 HARDWARE
7.1 Connections
General view of the module is show as below and details of each connection are described on it.
QK-W015 use 12VDC 1.0Amp power. The outside and inner diameter of the plug is 5.5mm and
2.1mm.
Quark-Elec Application Note
http://www.quark-elec.com 11 of 13 2014
V1.1
Figure 11 mechanical drawing
7.2 RF main sockets
Customer can select USA, European or UK type RF main sockets. Quark-elec standard RF
main sockets support 2000 Watts power rating.
Although QK-W015 have running specific algorithm to increase the RF transmission reliability,
Quark-elec cannot guarantee 100% of proper action rate of RF main sockets. QK-W015 RF
signal could be affect by other nearby RF devices such as bell ring, car key, cordless phone,
mobile phone, RF alarm system. The following is a real test result taken in a house
environment in the UK.
Distance between QK-W015 and
433Mhz RF main sockets
Proper action rate (RF main sockets been
successfully trigged by QK-W015)
2 meters 100.0%
5 meters 100.0%
NC
1
NO
1
CO
M1
C
OM
1
NC
2
NO
2
CO
M1
CO
M2
NC
3
NO
3
CO
M1
C
OM
3
12V
RF 433MHz aerial
Reset
CO
M1
LED2
LED1
Quark-Elec Application Note
http://www.quark-elec.com 12 of 13 2014
V1.1
8 meters 99.2%
10 meters 98.1%
15 meters 95.4%
20 meters 93.7%
7.3 Enclosure
IP56 Insulation Class 2 plastic enclosure, 115mm*90*40 external dimension is used for QK-
W013.
Figure 12 Enclosure drawing
8 OPERATING SPECIFICATIONS
Item Specification
Operating Temperature -25°C to +80°C
Storage Temperature -40°C to +85°C
DC Supply 12.0V(+/-10%)
Average Supply Current (typical
quiescent)
160mA
Supply Current in Busy Period(data
transmission)
190mA
WLAN Standard IEEE 802.11 b/g/n
Quark-Elec Application Note
http://www.quark-elec.com 13 of 13 2014
V1.1
Operating Frequency 2.4000 to 2.4835 GHz
Receive Sensitivity -85 dBm @ 11Mbps, -70 dBm @ 54Mbps
Transmit Mean Output Power +17 dBm for 802.11b, +13 dBm for 802.11g, +12 dBm for
802.11n
WiFi Antenna Build-in module U.FL antenna connector
Encryption Support for WEP40/64, WEP104/128, WPA-PSK, WPA2-
PSK, AES and TKIP
433Mhz Transmitting Power 1W
433Mhz Modulation Mode ASK (AM)
RF Transmission Power <10mW
RF Emission Distance 25 to 50 meters (open air condition)
Rated Current on Relay 7A240VAC
Rated Voltage on Relay 90V-245V
Power rating on RF main sockets < 2000 W
Please feel free to order our products from our onlinemall:
http://www.quark-elec.com/onlinemall/
For more technical information and enquires please go to Quark-elec forum:
http://quark-elec.com/forum/
For sales and purchasing information, please email us: [email protected]
Quark Electronics (UK)
24 Meadowbank,Hitchin
Herts. UK
SG4 0HY