21
PULSE LASER WIRE Laser pulse storage in an optical cavity as a beam monitor & an X-ray source Kaori Takezawa Kyoto Univ. 2nd Mini-Workshop on Nano Project at ATF 12 th Dec. / 2004

PULSE LASER WIRE Laser pulse storage in an optical cavity as a beam monitor & an X-ray source

Embed Size (px)

DESCRIPTION

PULSE LASER WIRE Laser pulse storage in an optical cavity as a beam monitor & an X-ray source. Kaori Takezawa Kyoto Univ. 2nd Mini-Workshop on Nano Project at ATF 12 th Dec. / 2004. OVERVIEW PRINCIPLE OPTICAL CAVITY EXPERIMENTAL SETUP CONCLUSION FUTURE PLAN. 2. 1.OVERVIEW. 3. - PowerPoint PPT Presentation

Citation preview

Page 1: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

PULSE LASER WIRE Laser pulse storage in an optical cavity as a beam monitor & an X-ray source

PULSE LASER WIRE Laser pulse storage in an optical cavity as a beam monitor & an X-ray source

Kaori Takezawa

Kyoto Univ.

2nd Mini-Workshop on Nano Project at ATF

12th Dec. / 2004

Kaori Takezawa

Kyoto Univ.

2nd Mini-Workshop on Nano Project at ATF

12th Dec. / 2004

Page 2: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

1. OVERVIEW

2. PRINCIPLE

3. OPTICAL CAVITY

4. EXPERIMENTAL SETUP

5. CONCLUSION

6. FUTURE PLAN

1. OVERVIEW

2. PRINCIPLE

3. OPTICAL CAVITY

4. EXPERIMENTAL SETUP

5. CONCLUSION

6. FUTURE PLAN

22

Page 3: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

1.OVERVIEW   1.OVERVIEW  

33

Pulse Laser Wire

(Storage laser pulses in optical cavity ):

The systems for New X-ray source & New bunch length monitor at a storage ring

Page 4: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

1.OVERVIEW   1.OVERVIEW  

33

714MHz Cavity

Electron repetition rate : 357MHzElectron bunches

Laser Repetition rate : 357MHz laser pulses

ScatteredGamma beam

Compton Scattering in every 357MHz

As an X-ray source :

An optical cavity store higher peak power and get higher flux X-ray with pulse CW laser than CW laser.

As Beam monitor :

By scanning the laser pulse’s phase in the cavity and measuring the Compton signal count rate ; an electron bunch length profile is obtained.

Phase Scan

Page 5: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

2.PRINCIPLE : Storage of laser pulse2.PRINCIPLE : Storage of laser pulse

44

Resonance condition : Perfect resonance : L = L

Not resonance : L ≠ L

Imperfect Resonance : L ~ L

laser

laser

laser

cavity

cavity

cavityThe relationship with laser and cavity :

The ext. cavity’s parameters ; enhancement factor , reflectivity , …. is the function of Δl and laser pulse width.

Page 6: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

2.PRINCIPLE : Enhancement factor 2.PRINCIPLE : Enhancement factor

55

The reflectivity is bigger at resonance point with Δl ≠0,.this means that enhancement factor is smaller . And data says laser pulse width.

Page 7: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

2.PRINCIPLE :Count rate& Measurement2.PRINCIPLE :Count rate& Measurement

66

σ   = σ     +σ    +σ    +σ

~ σ

Laser pulse width

-

Laser beamwaist

e bunch length

e h-beamsize-22 22 2

Phase

σ   = σ    +σ

Verticalposition

22 2

Laser beamwaist

e v-beamwaist-

Signal flux

Laser pulse width

2 The electron bunch length is 20 ~ 40 psec (10mm) > Laser pulse width ( FWHM =7 psec ; 1 mm) >> Laserwire beamwaist( 120um ), electron’s horizontal beamsize ( 100um )

Suppose both electron bunch and laser pulses have a Gaussian intensity distribution, The measured profile is also a Gaussian shape.

Page 8: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

3.OPTICAL CAVITY    3.OPTICAL CAVITY   

77

Page 9: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

3.OPTICAL CAVITY : The design3.OPTICAL CAVITY : The design

88

• Cavity length : 714 MHz +/- 2 kHz ( from PZT dynamic range )

• Mirrors

• The radius of curvature : 250 mm

• The reflectivity : 0.997 +/- 0.001

• Beamwaist > 200 um

Cavity length is 210mm. It is easy to adjust cavity length with short cavity.For cavity’s dynamic range , long PZT is used ( 10um ).

Finesse is ~ 1000 . But Maximum finesse is ~ 500 ,when the cavity , the length is 714MHz , stores laser pulses, which repetition rate is 357MHz. For enhanced laser pulses in the cavity , Next pulse come after 4times reflection

It is difficult to make thin laserwires at long cavity length .

Adjustment with PZT714MHz

ρ= 250mmR = 0.997

Page 10: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

3.OPTICAL CAVITY : feedback circuit3.OPTICAL CAVITY : feedback circuit

99

Transmission

Mode locked Laser

Laser Rep.rate feedback

Signal Generator

Ring RF standard 10MHz

357MHz

PZT voltage

PI circuitDC

Shoulder feedback system( OFF : background)

By a phase detector, the signal is synchronized with Ring 357MHz

A trombone for a signal delay

Feedback ON/OFF

Page 11: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

4.EXPRIMENTAL SETUP : Layout4.EXPRIMENTAL SETUP : Layout

1010

Page 12: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

4.EXPERIMENTAL SETUP : Optics4.EXPERIMENTAL SETUP : Optics

1111

Isolator

Cavity

Transmission

Reflection

Injection mirrors

Laser head

λ/2 λ/4

Page 13: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

5.CONCLUSION : Timing scan5.CONCLUSION : Timing scan

1313

2.8 nsec

Bunch length

← Compton signal

In timing scan, we detect Compton signals and the laser pulse’s phase in cavity when signals come.

Enhanced laser pulses 2times go and back in the cavity , and are scattered 4times every 2.8 nsec.

Page 14: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

5.CONCLUSION : count rate 5.CONCLUSION : count rate

1414

Calculated maximum count rate is ~ 2500 [Hz/mA] .

Actual count rate is ~ 1500 because of imperfectly adjustment cavity length with shoulder feedback system.

σ=laser beamwaist

Page 15: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

5.CONCLUSION : VS. RF voltage5.CONCLUSION : VS. RF voltage

1515

Data at 19th Nov. had a sharp peak , but There was no peak at 01st Dec. ( Because of the change Ring tune ? )

Page 16: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

5.CONCLUSION : VS. the beam current5.CONCLUSION : VS. the beam current

1616

When the number of electron per bunch is bigger , The Gauusian shape of scattered photons count rate change. (The life time of low current electron beam at ring is long )

Count rate [Hz/mA]

Phase [psec]

Page 17: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

6. FUTURE PLAN 6. FUTURE PLAN

1717

• For high count rate :

• Problems as a bunch length monitor :

• And now

We plan the higher finesse cavity (mirror R=0.999) and thin laserwire with beamwaist 50um. In the plan , the enhancement factor is 10 times as much as current systems. New feedback system, Tilt locking can adjust cavity length at resonance peak . We will test those systems in this winter.

In current systems, It takes about 20 seconds for data taking . Data can be taken at low current electron beam , but at high current beam cannot .

Next week, we will measure bunch length with pulse laser wire timing scan and streak camera. If I can, we will test tiltlocking feedback system.

Page 18: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

Kyoto Univ.Kyoto Univ.

NIRSNIRS

JaeriJaeri

KEKKEK

ISSPISSP

And you !!And you !!

Thanks !Thanks !

2nd Mini-Workshop on Nano Project at ATF12th Dec. / 2004

2nd Mini-Workshop on Nano Project at ATF12th Dec. / 2004

Page 19: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

11

1. 企画書の目的と概要1. 企画書の目的と概要

Page 20: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

1. 企画書の目的と概要1. 企画書の目的と概要

11

Page 21: PULSE LASER WIRE Laser pulse storage in an optical cavity  as a beam monitor & an X-ray source

4.EXPERIMENTAL SETUP : Data taking4.EXPERIMENTAL SETUP : Data taking

1212