4
PSE100-series AC/DC 60 to 100 W INPUT / OUTPUT • 110 or 230 Va.c. models 100 W • Worldwide AC input 85 to 264 Va.c. 60 W • Train born AC inputs • Single outputs from 5 to 48 Vd.c. • Low ripple and noise FEATURES • Conformally coating, tropic • Accessible on front: • Output voltage adjustment • Output voltage measurement • Output OK status green LED OPERATION • Operating temperature range -25 to +70 °C • High efficiency • Fully encapsulated, meets IP20 as standard • Convection cooled EMC • EN IEC 61000-6-3, Emission • EN IEC 61000-6-2, Immunity • EN IEC 61000-4-4, 4 kV • Both input and output OUTPUT RATING & TYPE CODE OUTPUT INPUT Voltage Current Power 85 - 264 V 85 - 135 V 176 - 264 V 5V 12.0 A 1 60 W PSE60ACW5 5V 20.0 A 1 100 W PSE100ACR5 PSE100AC5 13.2 V 4.50 A 60 W PSE60ACW13.2 13.2 V 7.60 A 100 W PSE100ACR13.2 PSE100AC13.2 15 V 4.00 A 60 W PSE60ACW15 15 V 6.70 A 100 W PSE100ACR15 PSE100AC15 24 V 2.50 A 60 W PSE60ACW24 24 V 4.20 A 100 W PSE100ACR24 PSE100AC24 48 V 1.30 A 60 W PSE60ACW48 48 V 2.10 A 100 W PSE100ACR48 PSE100AC48 How to read our product code: Example PSE100AC24 PSE100 = Family code AC = input voltage code AC 24 = Output voltage 24 V 1) -25 to +55 °C 100% load, 70 °C at 75% load. With extra cooler the ratings is 100% @ +70 °C , see option T3 and mechanical drawing figure 5.

PSE100-series AC/DC 60 to 100 W · PSE100-series AC/DC 60 to 100 W INPUT / OUTPUT • 110 or 230 Va.c. models 100 W • Worldwide AC input 85 to 264 Va.c. 60 W • Train born AC inputs

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PSE100-series AC/DC 60 to 100 W · PSE100-series AC/DC 60 to 100 W INPUT / OUTPUT • 110 or 230 Va.c. models 100 W • Worldwide AC input 85 to 264 Va.c. 60 W • Train born AC inputs

PSE100-series AC/DC 60 to 100 WINPUT / OUTPUT • 110or230Va.c.models100W• WorldwideACinput85to264Va.c.60W• TrainbornACinputs• Singleoutputsfrom5to48Vd.c.• Lowrippleandnoise

FEATURES • Conformallycoating,tropic• Accessibleonfront: •Outputvoltageadjustment•Outputvoltagemeasurement•OutputOKstatusgreenLED

OPERATION • Operatingtemperaturerange-25to+70°C• Highefficiency• Fullyencapsulated,meetsIP20asstandard• Convectioncooled

EMC • ENIEC61000-6-3,Emission• ENIEC61000-6-2,Immunity• ENIEC61000-4-4,4kV• Bothinputandoutput

OUTPUT RATING & TYPE CODEOUTPUT INPUT

Voltage Current Power 85 - 264 V 85 - 135 V 176 - 264 V

5V 12.0A1 60W PSE60ACW5

5V 20.0A1 100W PSE100ACR5 PSE100AC5

13.2V 4.50A 60W PSE60ACW13.2

13.2V 7.60A 100W PSE100ACR13.2 PSE100AC13.2

15V 4.00A 60W PSE60ACW15

15V 6.70A 100W PSE100ACR15 PSE100AC15

24V 2.50A 60W PSE60ACW24

24V 4.20A 100W PSE100ACR24 PSE100AC24

48V 1.30A 60W PSE60ACW48

48V 2.10A 100W PSE100ACR48 PSE100AC48

How to read our product code:

Example PSE100AC24

PSE100 = Family code

AC = input voltage code AC

24 = Output voltage 24 V

1) -25 to +55 °C 100% load, 70 °C at 75% load. With extra cooler the ratings is 100% @ +70 °C , see option T3 and mechanical drawing figure 5.

Page 2: PSE100-series AC/DC 60 to 100 W · PSE100-series AC/DC 60 to 100 W INPUT / OUTPUT • 110 or 230 Va.c. models 100 W • Worldwide AC input 85 to 264 Va.c. 60 W • Train born AC inputs

INPUT VOLTAGE RATINGS

FEATURES OPTIONAL FEATURESConformal coating PSE100isconformalcoatedtowithstandnoncondensingtropicalenviromentRh95%.

Logic under voltage alarm -B1Abuiltinlogicalarmchangestoalarmstateifthecon-verteroutputvoltagedropsbelow-10%ofnominaloutput.ThealarmcircuitalsocontrolstheDCOKLED.Astandardunitisequippedwithalogicsignal.DCOKorPOWERGOODsignaluselogic1.Thedrivevoltageis6to10V,5mA=logic1,seefigure2.

Voltage adjustVoltageadjustmentandoutputvoltagemeasurementaccessiblefromfrontpanel.

Over voltage limit OVL Asecondregulationcicuittakesoverincasethemainregulationfails.Theoutputvoltageislimitedtoapproximately+15%overnominaloutputvoltage.

Overvoltage protection OVP-ATheoutputvoltageislimitedto15%overnominal outputvoltage.Athyristorshort-circuitstheoutput.

Built in series diode -C (Derating 20 %)Aseriesdiodeontheoutput,whichismountedinsidethecase.Usethisoptionwhenoutputisconnectedinparallelwithotherpowersuppliestoachiveredundancy.Theout-putpowermightbederated.It´smodeldependent,pleasecontactfactory.

Built in series diode with resistor - CRTheCRoptionautomaticallybalancetheloadbetween2ormoreparalleledPSEunits.

Remote sense -SThevoltagesensingcanbeputattheloadtocompensateforvoltagedrop.Isastandardfeatureon5Voutput.Thesensecancompensateforvoltagedropsupto5%ofthenominalvoltage.

2.5 kVa.c. isolation output/case, option E2

Under voltage alarm relay -B2ThelogicalarmoutputisreplacedwitharelaywithselectablealarmlogicNOorNC.Alarm=Noinputorlowoutput<-10%ofnominaloutput,seefigure3. Therelayisrated30V,0.5A(a.c.&d.c.).

Extra cooler, option T3ThePSEcasecanaccommodate2extracoolers.Someoptionse.gseriesdiodewillrequireanextracoolertoavoidderating20%ortheEN50155/IEC60571T3temper-atureclassificationrequiring+85°Cduring10min. Eachcooleris10mm,whichincreasethesizeandweightaccordingly.

Figure 1. Pin-out DIN 41612, H15

Figure 3. Alarm relay output Option B2

Figure 2. 5 V logic alarm signal Option B1

INPUT

Nominal inputs Input range Code

100,110,220,230,240Va.c. 85-264V ACW

100,110Va.c. 85-135V ACR

220,230,240Va.c. 176-264V AC

Page 3: PSE100-series AC/DC 60 to 100 W · PSE100-series AC/DC 60 to 100 W INPUT / OUTPUT • 110 or 230 Va.c. models 100 W • Worldwide AC input 85 to 264 Va.c. 60 W • Train born AC inputs

GENERAL DATA / INPUT DATA OUTPUT DATA

MECHANICAL DRAWING

LABEL VALUE

Sourceregulation 0.2%

Loadregulation(0to100%load) 0.2%

Transientrecoverytimefor

10to100%voltagedeviation

<2ms

3%

Outputripple(100kHz)1 Typ10mVp-p

Inputripple(100Hz)Uin230Va.c. <10mVrms,50mVp-p

Inputripple(100Hz)Uin110Va.c. <20mVrms,100mVp-p

Emission/Immunity Seepage4

Temperaturecoefficient 0.02%/°C

Minoutputadjustmentrange

adjustablewitha15turn

potentiometer

90-110%

Currentlimit,rectangular 105%

Remotesense OptionS

Softstart Yes

Start-uptime <1s

Reversevoltageprotectiononoutput Paralleldiode

Hold-uptime,contactfactory

PSE60ACW(230Va.c.)

PSE60ACW(110Va.c.)

PSE100AC(230Va.c.)

PSE100ACR(110Va.c.)

20ms

3ms

10ms

3ms

Efficiency2PSE60ACW

PSE100AC(230Va.c.)

PSE100ACR(110Va.c.)

80-85%

80-88%

82-91%

Operatingtemperaturerange

at100%load,conductioncooling

withoutputs>10V

-25to+70°C

Operatingtemperaturerange

at100%load,conductioncooling

withoutputs<10V -25to+55°C

Storagetemperaturerange -40to+85°C

Optional -40°C

LABEL VALUE

Designtopology Push-Pull

Switchingfrequency 100kHz

Emission/Immunity Seepage4

ACfrequencyrange 48-420Hz

Inrushcurrentlimit WithNTC

Powerconsumptionatnoload 3to5W

VibrationEN/IEC61373 BodymountedClassB

Isolation Seetablepage4

FireProtectionEN45545-2HL3

level4.3.2rule1andfigure1

“Nonlistedproduct”

<100g

Dimension(DxHxW)mm 167x106x37|47|57

Weight 0.8-1.3kg

1. The output ripple might increase to 0.5% RMS of Vout, when EN IEC 61000-4-3, 10 V/m test is applied. 2. Lowest efficiency measured within the whole input voltage range at 100% load.

Mechanical Options FrontpanelforEuroformat,optionL,seefigure4-68TEforPSE60andPSE10010TEfor5Voutputwithextracooler,optionT3Wallmountingpanels,optionN,seefigure7and8Includingconnectorholder.H15CageClamptypefemale-H15-CC(ThecableratingisAWG16or<1.5mm2.Thatmakesitnotusablefor5Voutputs)

H15FastOn6.3mmfemale-H15-TDINrailTS35clips-Q,seefigure8

42 mm

200 mm

49 m

m49

mm

106

mm

190 mm

15 mm13 mm

210 mm4.2 mm

(52mm withextra cooler)

Figure 6. 3HE 19” sub rack mounting.

Figure 4. Dimensions.

Weight: 0.8 kg.

Figure 8. Wall mounting Option -N

Figure 7. Dimensions with option N, wall mounting Weight: 0.95 kg and with extra cooler T3 | 2xT3: 1.1 | 1.3 kg.

PSE wall mounted.Using PSE wall mounting kit, option N, with connector holder, female H15 connector with cage clamp or tab connectors (Optional).

PSE DIN-rail mounted.Using PSE wall mounting kit, option N with addition of 2x DIN-rail clips, (Optional)

PSE mounted in a 19” Sub-rack. Standard unit.

PSE mounted in a 19” Sub-rack with L panel 8, 10 or 12 TE (Optional)

Figure 5. Optional extra cooler version. Weight: 1xT3 1.1 | 2xT3 1.3 kg

Page 4: PSE100-series AC/DC 60 to 100 W · PSE100-series AC/DC 60 to 100 W INPUT / OUTPUT • 110 or 230 Va.c. models 100 W • Worldwide AC input 85 to 264 Va.c. 60 W • Train born AC inputs

EMC

CE MARKPSE100meetstherequirementsdefinedbyCEmarkas apparatus.

PSE100meetsrequirementsofEMCdirectiveandlow voltagedirective(LVD)andRoHSIIdirective.

ThePSE100familyisinrespecttoEMC,astandaloneunitthatcanalsobeinstalledinanyotherenvironmentbyaprofessionalinstaller.

Pleasenotethatproductstandardscandemanddifferentlevelsorotherbasicstandardtests.Wetestaccordingtolevelsbelow.Forhigherlevelsorothertests,contact factory

SAFETY STANDARD EN/IEC 60950 ISOLATIONTESTABLELEVELS TESTVOLTAGE

Input/Output 2.5kVa.c./4kVd.c.

Input/Case 2.5kVa.c./4kVd.c.

Output/Casealloutputs 2kVd.c.

ISOLATIONTESTABLELEVELS SAFETYISOLATION

TransformerisolationIn/Out 4kVa.c./8mm

HEADOFFICEPolyampAB Box925 SE-19129Sollentuna Sweden Phone: +46859469300 Telefax:+46859469305

SALESOFFICE PolyampAB Box229 SE-59725Åtvidaberg Sweden Phone: +4612085410 Telefax:+4612085405

Email:[email protected]

SALESOFFICESwitchCraftS.A RuelbelAir63 CH-2300LaChaux-de-fondsSwitzerland Phone: +41329678800Telefax:+41329678809

EMCSTANDARDS EMCPERFORMANCE REMARKS

Emission standards EN IEC 61000-6-3 Commercial and light-industrial environments

Input Output

EN55016CISPR16(0.15-30MHz) OK OK opt.EN55022levelB

EN55016CISPR16(30-1000MHz) OK Enclosuretest

Immunity standards EN IEC 61000-6-2 Industrial environments

ENIEC61000-4-2 8kV/15kV Contact/air,Enclosuretest

ENIEC61000-4-3 10V/mAM-Modulated2 Outputripplecanincreaseto

0.5%ofVoutEnclosuretest

ENIEC61000-4-4 ±4kV ±4kV

ENIEC61000-4-5 ±1kV/±2kV1 ±0.5kV/±1kV Line-line2Ω/Line-case12Ω

EN50121-3-2,IEC62236-3-2 ±1kV/±2kV ±1kV/±2kV Line-line42Ω/Line-case42Ω

ENIEC61000-4-6 10VRMS 10VRMS AM-Modulated

ENIEC61000-4-8 Notsensitive Enclosuretest

ENIEC61000-4-10 Notsensitive Enclosuretest

ENIEC61000-4-11 Yes NA

1. Higher level 2 kV / 4 kV with external filters, contact factory.

2. Level increased to 20 V/m on T-inputs.

We use the EMC product standard ”Low voltage power supplies DC output” EN 61204-3 as base for measurement principles. The Immunity EMC levels are elevated in order to comply to EN 50121-3-2 (IEC 62236-3-2) Railway application: Rolling stock – Apparatus, and EN 50121-4 (IEC 62236-4) Railway application: Signaling and telecommunication apparatus. Also to meet relevant parts of IEC 61000-6-5 Generic Standards – Immunity for power stations and substation environments.

Polyamp AB 4287-13 PSE100 AC-DC Converters

Installation Class I, optional Class II