3M Food Safety3M™ Tecra™ Pathogen and Toxin Visual Immunoassay (VIA) Tests
ResultsTrust.
ProvenYou Can
2461_TecraBrochure_13-7.indd 1 11/15/11 2:37 PM
Tests you can trust.
Results you can see.
When testing for pathogens and toxins, you can’t leave anything to chance.
You need a reliable food safety test with a solid history of proven performance.
3M™ Tecra™ Pathogen and Toxin Visual Immunoassay (VIA) Tests deliver a
precise, AOAC®-approved method to accurately test raw materials, finished
products and environmental surfaces in production facilities.
2461_TecraBrochure_13-7.indd 2 11/15/11 2:37 PM
#2#1 #3 #4 #5
3M™ Tecra™ Pathogen and Toxin Visual Immunoassay (VIA) Tests
Easy-to-use testingPathogen testing needs to be a simple, basic process because too much
is at stake for your business and consumers. 3M Tecra VIA Tests deliver
results that are easy to read using a visual color scale. With these
straightforward and accurate results, your productivity will increase,
and training the employees in your lab will be as fast and simple
as the test itself.
Easy-to-read results3M Tecra VIA Tests achieve a reliable result with easy-to-follow steps
that help reduce the risk of contamination. Whether you are new to
immunoassay testing, you want a dependable backup system, or you
are looking for a solid method that’s cost-effective and easy to use, 3M
Tecra VIA Tests are right for you.
Adaptable lab solutions3M Tecra VIA Tests offer flexible solutions to make testing more efficient. Our system allows you
to choose the kits, broth and supplements for the specific pathogen that you are testing. Whether
you are working with low, medium or high-volume applications, 3M Tecra VIA Tests can easily
accommodate your needs.
2461_TecraBrochure_13-7.indd 3 11/15/11 2:37 PM
More results in less timeWith a higher throughput, our system can test more samples per run — up to 96 samples in a single plate.
If you need to increase capacity, it’s as simple as running multiple plates. Testing more samples with fewer
technicians means higher productivity. Because no equipment is needed to use 3M™ Tecra™ VIA tests,
you’ll avoid delayed results and incurred expenses that can happen in the event of equipment breakdown.
2461_TecraBrochure_13-7.indd 4 11/15/11 2:37 PM
When factoring in labor and materials, many facilities find that their current cost per test is too high. Since
3M™ Tecra™ VIA Tests reduce both prep time and labor with competitive material costs, you can get started with
a low investment that will save you time and money. 3M Tecra VIA Tests don’t require expensive equipment, but
as your lab and your budget grow, you can choose to add semi-automated capability with no new training required.
Spend less and test more
you can count on.
Flexibility with results
2461_TecraBrochure_13-7.indd 5 11/15/11 2:37 PM
A full range of tests
3M™ Tecra™ Salmonella VIA•• 40 hr enrichment followed by 2 hr assay•• Sensitivity: 1-5 CFU-25 g sample•• Detects motile and non-motile Salmonella
3M™ Tecra™ E. coli O157 VIA•• 18 hr enrichment followed by 2 hr assay•• Single enrichment•• Sensitivity: 1-5 CFU-25 g sample•• Also detects E. coli O157:H7
3M™ Tecra™ Campylobacter VIA•• 40 hr enrichment followed by 2.5 hr assay•• Single enrichment in proprietary broth•• Enrichment performed under aerobic conditions•• Sensitivity: 1-5 CFU-25 g sample
3M™ Tecra™ Staph Enterotoxin VIA•• Detects preformed Staphylococus aureus
Enterotoxin (SET), including SET A, B, C1, C3, D and E in food samples
•• Less than 30 min sample preparation followed by 4 hr assay
•• Sensitivity: 1 ng/mL of sample extract
3M™ Tecra™ Staph Enterotoxin ID VIA•• Detects and identifies preformed Staphylococus
aureus Enterotoxin (SET), including SET A, B, C, D, and E in food samples
•• Less than 30 min sample preparation followed by 4 hr assay
•• Sensitivity: 1 ng/mL of sample extract
3M™ Tecra™ Bacillus Diarrhoel Enterotoxin VIA•• Detects preformed Bacillus Diarrhoel Enterotoxin
in food samples•• Less than 30 min sample preparation
followed by 4 hr assay•• Sensitivity: 1 ng/mL of sample extract
3M™ Tecra™ Salmonella ULTIMA VIA•• 40 hr enrichment followed by 2 hr assay•• No post enrichment required•• Sensitivity: 1-5 CFU-25 g sample
3M™ Tecra™ Listeria VIA•• Foods: 46 hr enrichment followed by 2 hr assay•• Environmental: 40 hr enrichment
followed by 2 hr assay•• Sensitivity: 1-5 CFU-25 g sample
or 1-5 CFU/swab
3M™ Tecra™ Staph aureus VIA•• 24 hr enrichment followed by 2 hr assay•• Single enrichment in proprietary broth•• Sensitivity: 1-5 CFU-25 g sample
3M™ Tecra™ Pseudomonas VIA•• 48 hr enrichment followed by 2.5 hr assay•• Single enrichment in proprietary broth
2461_TecraBrochure_13-7.indd 6 11/15/11 2:37 PM
Support you can rely on3M Food Safety products are at work in more than 60 countries around the globe
to help keep businesses such as yours moving forward. Our passion is to work with
you to discover new food safety solutions that protect your brand, mitigate your risk
and improve your operations. And every day, our people are there to support you
locally by providing technical help and exceptional service.
2461_TecraBrochure_13-7.indd 7 11/15/11 2:37 PM
With more than 25 years of global experience in the food and beverage
industry, 3M Food Safety offers a full line of products that work together
for consistent, reliable results.
To learn more about 3M™ Tecra™ VIA Tests or other product solutions from 3M Food Safety, contact your local 3M representative or call 1-800-328-1671.
3M Food Safety3M CenterBuilding 275-5W-05St. Paul, MN55144-1000U.S.A.1-800-328-6553www.3M.com/foodsafety
3M CanadaPost Office Box 5757London, Ontario N6A 4T1Canada1-800-364-3577
© 2011 3M. All rights reserved. 3M and Tecra are trademarks of 3M.
Used under license in Canada. Please recycle. Printed in U.S.A.
AOAC is a registered trademark of the Association of Analytical Communities International.
End-to-end solutions
•• 3M™ Hydrated and Dry Enviroswabs
•• 3M™ Hydrated and Dry Sponges
•• 3M™ Hydrated and Dry Sponge-Sticks
•• 3M™ Sample Bags
Sample collection•• 3M™ Dehydrated Broths and Supplements
•• 3M™ Ready-To-Use Broths and Supplements
•• 3M™ Sample Bags
Sample enrichment
70-2009-9485-6
•• 3M™ Tecra™ Pathogen and Toxin Visual Immunoassay (VIA) Test Kits
•• Automated Strip Washer and Microplate Reader
•• 3M™ Tecra™ Environmental Listeria Test
•• 3M™ Electronic Pipettor II
Sample assay
2461_TecraBrochure_13-7.indd 8 11/15/11 2:37 PM