MR. B. & MRS. R. LAND
LOT 47EDGECLIFF DRIVESANCTUARY COVE
JOB NUMBER - 4639
NOTES:* IMAGES ARE DIAGRAMATIC ONLY
* REFER TO ELEVATIONS FOR DETAILS
PROPOSED DWELLING FOR
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
2 23
H120912I021012J151112K200314L260314
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
3 23
H120912I021012J151112K200314L260314
DESCRIPTIONREV. DATE
PRELIMINARY PLANS ISSUEDA 180512
DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans), TOBE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.
WIND SPEED AS NOMINATED ON BRACING PLAN.
PROVIDE LIFT OFF HINGES TO W.C OR OPEN OUT DOOR OR MIN 1200mm CLEARANCEFROM DOOR TO PAN.
EXHAUST FANS FROM SANITARY COMPARTMENTS TO BE DUCTED TO THE OUTSIDE
ARE AIR OR TO A VENTED ROOF SPACE AND AS PER AS 1668.2
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGUALTIONS,STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACUAL OBLIGATIONS.
ALL CONSTRUCTION MATERIALS SUPPLIED MUST TAKE INTO ACCOUNT PROXIMITY TOCOASTAL OR INDUSTRIAL ENVIRONMENTS, IN ACCORDANCE WITH MANUFACTURERS
SPECIFICATIONS
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THEAUTHOR.
MR. B. & MRS. R. LANDLOT 47
EDGECLIFF DRIVESANCTUARY COVE
JOB NUMBER - 4639
GENERAL NOTES
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,
SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERINGMATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS
CONFORM TO THE BUILDING CODE OF AUSTRALIA 2006, CURRENT AUSTRALIANSTANDARDS, BUILDING REGULATIONS AND TOWN PLANNING REQUIREMENTS,
REPORT ANY DISCREPANCIES TO THIS OFFICE.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF
AUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATIONAS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDINGAS 1684 - 2010 NATIONAL TIMBER FRAMING CODEAS 2049 - 2002 ROOF TILESAS 2050 - 2002 INSTALLATION OF ROOF TILESAS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTIONAS/NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGSAS 3600 - 2000 CONCRETE STRUCTURESAS 3660 - 2000 BARRIERS FOR SUBTERRANEAN TERMITESAS 3700 - 2001 MASONRY IN BUILDINGSAS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGSAS 3786 - 1993 SMOKE ALARMSAS 4055 - 2006 WIND LOADINGS FOR HOUSINGAS 4100 - 1998 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVIL
ENGINEERING COMPUTIONS AND DRAWINGS.
SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE
WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOXINDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR
ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASEiii) FULLY GLAZED DOORS
iv) SHOWER SCREENSv) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL
vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY
WITH MANUFACTURER, FLASHING ALL ROUND.
ALL GUTTERS TO BE STRAMIT QUEENSLANDER QUAD GUTTERING WITH MIN. 100x75RECTANGULAR OR 100 dia. DOWNPIPES, EACH DOWNPIPE SHALL SERVICE A MAXIMUM
ROOF AREA OF 36 sq.m OR SHALL BE POSITIONED AS PER AS 3500.3, 2003, SECTION 3.
STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BY
THE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVERTHEFLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF
PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL
CORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT IS
RECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITYOF BUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR.
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BE
IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF
THE WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL ANDWITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sq
FOR INTERNAL WALLS BELOW BEARER.
THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5 BATTS AND REFLECTIVE FOIL
TO EXTERNAL WALLS OR AS PER ENERGY RATING.
STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.
BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND IN
ACCORDANCE WITH BCA 3.9.2FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE
CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLEDEFLECTION) OF THE BCA..
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF
EXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
LEGEND
CJ CONSTRUCTION JOINTDP DOWNPIPEFP FIRE PLACEFW FLOOR WASTEHWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBESD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS
RAIN WATER STORAGE TANKS IN ACCORDANCEWITH QUEENSLAND DEVELOPMENT CODE - PART4.2 & 4.3
MANDATORY RAINWATER TANK 3000L PER DUPLEX UNIT, 5000L PER
SINGLE DETACHED DWELLING, FOR WC'S, WASHING MACHINE COLDWATER TAPS & EXTERNAL TAPS. LOCATION TBC ON SITE TO PROVIDE
THE LESSER OF 100m2 OR HALF-ROOF CATCHMENT AREA, WITH 15LITRE FIRST FLUSH DIVERSION AS PER BUILDER. AUTO SWITCHING
DEVICE OR TRICKLE TOP-UP SYSTEM REQUIRED ATTACHED TO TOWNWATER, WITH BACKFLOW PREVENTION DEVICE. ALL TANKS TO BE MIN
450mm FROM SIDE OR REAR BOUNDARY. TANKS OVER 2.4M HIGH TO BEMIN 1.5M FROM SIDE OR REAR BOUNDARY. RELAXATION REQUIRED FOR
TANKS IN 6M FRONT SETBACK. OVERFLOW TO BE CONNECTED TO
LEGAL POINT OF DISCHARGE.
SITE NOTES
ALL STORMWATER AND DRAINAGE TO BE IN COMPLIANCE WITH BCA
PARTS 3.1.2 & 3.5.2 AS WELL AS AS/NZS 3500.
ENSURE 90mm DIAMETER AGRICULTURAL DRAINS ARE PROVIDED TOTHE BASE OF ALL CUTS AND RETAINING WALLS AND ARE CONNECTED
TO THE STORMWATER SYSTEM VIA SILT PIT/S TO THE RBSREQUIREMENTS.
THE EXTERNAL FINISHED SURFACE SURROUNDING THE BUILDINGMUST BE DRAINED TO MOVE SURFACE WATER AWAY FROM THE
BUILDING AND GRADE TO PROVIDE A SLOPE NOT LESS THAN 50mmOVER THE FIRST 1000mm FROM THE BUILDING.
A MINIMUM HEIGHT OF 150mm SHALL BE MAINTAINED BETWEEN THE
TOP OF THE OVERFLOW GULLY RISER & THE LOWEST FIXTURE
CONNECTED TO THE DRAIN. THE OVERFLOW GULLY RISER SHALL BELOCATED AT 75mm ABOVE SURROUNDING GROUND LEVEL OR SHALL
BE FINISHED AT A HEIGHT TO PREVENT THE INGRESS OF WATERWHEN LOCATED IN A PATH OR PAVED AREA.
CONNECT DOWNPIPES TO LEGAL POINT OF DISCHARGE VIA 100mm
DIAMETER UPVC STORMWATER PIPE LAID WITH A MINIMUM FALL OF1:100, DISCHARGE TO THE SATISFACTION OF THE RELEVANT
AUTHORITY.
ALL STORMWATER DRAINAGE BELOW GROUND SHALL BE SEWER
GRADE WITH NO JOINTS UNDER SLAB INSTALLED TO AS3500.3, 2003.MINIMUM PIPE SIZE 100mm
MINIMUM GRADE 1:100
ALL POOL FENCING SHALL BE MIN. 1200mm HIGH AND INACCORDANCE
WITH AS 1926.1
PROPOSED DWELLING FOR
INT. & EXT. AMENDMENTS + ELEVATIONS ADDEDB 040612
FG DOORS ADDED TO ALFRESCOC 060612
ADD STEAM ROOM TO BASEMENTD 200612
COLOUR SELECTIONS ADDED TO ELEVATIONSE 290612
MINOR AMENDMENTS + ADDITIONAL INFO ADDED FOR A.R.C APPROVALF 300712
MINOR AMENDMENTS FOR A.R.C APPROVALG 020812
WORKING DRAWINGS ISSUEDH 120912
GF SLAB THICKNESS AMENDED TO 420mm, AS PER ENG.DETAILSI 021012
MINOR AMENDS- GARTE DRAIN TO POOL, SHOWER TO STEAM ROOMJ 151112
MINOR AMENDS- LANDSCAPE ASTRO TURF NEXT TO POOLK 200314ST
MINOR AMENDS- CONC. DECK ASTRO TURF 1M C'LEVEREDL 260314ST
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
4 23
H120912I021012J151112K200314L260314
REPORT STATUS DATE
WORKPLACE HEALTH & SAFETY REPORTCOMPLETED - DISCUSSED WITH & PROVIDED TOCLIENT ALONG WITH WORKING DRAWINGS 12-09-12
MR. B. & MRS. R. LANDLOT 47
EDGECLIFF DRIVESANCTUARY COVE
JOB NUMBER - 4639
b) SLIPPERY OR UNEVEN SURFACES
FLOOR FINISHES
Specified finishes have been selected to minimise the risk of floors and
paved areas becoming slippery when wet or when walked on with wet
shoes/feet. Any changes to the specified finish should be made in
consultation with the designer or, if this is not practical, surfaces with an
equivalent or better slip resistance should be chosen.
The owner is responsible for the selection of surface finishes in the
pedestrian trafficable areas of this building. Surfaces should be selected in
accordance with AS HB 197:1999 and AS/NZ 4586:2004.
STEPS, LOOSE OBJECTS AND UNEVEN SURFACES
Due to design restrictions for this building, steps and/or ramps are included
in the building which may be a hazard to workers carrying objects or
otherwise occupied. Steps should be clearly marked with both visual and
tactile warning during construction, maintenance, demolition and at all times
when the building operates as a workplace.
Building owners and occupiers should monitor the pedestrian access ways
and in particular access to areas where maintenance is routinely carried out
to ensure that surfaces have not moved or cracked so that they become
uneven and present a trip hazard. Spills, loose material, stray objects or
any other matter that may cause a slip or trip hazard should be cleaned or
removed from access ways.
Contractors should be required to maintain a tidy work site during
construction, maintenance or demolition to reduce the risk of trips and falls
in the workplace. Materials for construction or maintenance should be
stored in designated areas away from access ways and work areas.
2. FALLING OBJECTSLOOSE MATERIALS OR SMALL OBJECTS
Construction, maintenance or demolition work on or around this building is
likely to involve persons working above ground level or above floor levels.
Where this occurs one or more of the following measures should be taken
to avoid objects falling from the area where the work is being carried out
onto persons below.
1. Prevent or restrict access to areas below where the work
is being carried out.
2. Provide toeboards to scaffolding or work platforms.
3. Provide protective structure below the work area.
4. Ensure that all persons below the work area have
Personal Protective Equipment.
BUILDING COMPONENTS
During construction, renovation or demolition of this building, parts of the
structure including fabricated steelwork, heavy panels and many other
components will remain standing prior to or after supporting parts are in
place. Contractors should ensure that temporary bracing or other required
support is in place at all times when collapse which may injure persons in
the area is a possibility.
Mechanical lifting of materials and components during construction,
maintenance or demolition presents a risk of falling objects. Contractors
should ensure that appropriate lifting devices are used, that loads are
properly secured and that access to areas below the load is prevented or
restricted.
3. TRAFFIC MANAGEMENTParking of vehicles or loading/unloading of vehicles on this roadway may
cause a traffic hazard. During construction, maintenance or demolition of
this building designated parking for workers and loading areas should be
provided. Trained traffic management personnel should be responsible for
the supervision of these areas.
Construction of this building will require loading and unloading of materials
on the roadway. Deliveries should be well planned to avoid congestion of
loading areas and trained traffic management personnel should be used to
supervise loading/unloading areas.
Busy construction and demolition sites present a risk of collision where
deliveries and other traffic are moving within the site. A traffic management
plan supervised by trained traffic management personnel should be
adopted for the work site.
4. SERVICESRupture of services during excavation or other activity creates a variety of
risks including release of hazardous material. Existing services are located
on or around this site. Where known, these are identified on the plans but
the exact location and extent of services may vary from that indicated.
Services should be located using an appropriate service (such as Dial
Before You Dig), appropriate excavation practice should be used and,
where necessary, specialist contractors should be used.
(in locations with underground power)
Underground power lines are located in or around this site. All underground
power lines must be disconnected or carefully located and adequate
warning signs used prior to any construction, maintenance or demolition
commencing.
(in locations with overhead power lines )
Overhead power lines are near or on this site. These pose a risk of
electrocution if struck or approached by lifting devices or other plant and
persons working above ground level. Where there is a danger of this
occurring, power lines should be, where practical, disconnected or
relocated. Where this is not practical adequate warning in the form of bright
coloured tape or signage should be used or a protective barrier provided.
5. MANUAL TASKSComponents within this design with a mass in excess of 25kg should be
lifted by two or more workers or by mechanical lifting device. Where this is
not practical, suppliers or fabricators should be required to limit the
component mass.
All material packaging, building and maintenance components should
clearly show the total mass of packages and where practical all items
should be stored on site in a way which minimises bending before lifting.
Advice should be provided on safe lifting methods in all areas where lifting
may occur.
Construction, maintenance and demolition of this building will require the
use of portable tools and equipment. These should be fully maintained in
accordance with manufacturer’s specifications and not used where faulty or
(in the case of electrical equipment) not carrying a current electrical safety
tag. All safety guards or devices should be regularly checked and Personal
Protective Equipment should be used in accordance with manufacturer’s
specification.
6. HAZARDOUS SUBSTANCESASBESTOS
(for alterations to a building constructed prior to 1990)
This building was constructed prior to 1990 and therefore may contain
asbestos either in cladding material or in fire retardant insulation material.
The builder should check and, if necessary, take appropriate action before
demolishing, cutting, sanding, drilling or otherwise disturbing the existing
structure.
(for alterations to a building constructed prior to 1986)
This building was constructed prior to 1986 and therefore is likely to contain
asbestos either in cladding material or in fire retardant insulation material.
The builder should check and, if necessary, take appropriate action before
demolishing, cutting, sanding, drilling or otherwise disturbing the existing
structure.
POWDERED MATERIALS
Many materials used in the construction of this building can cause harm if
inhaled in powdered form. Persons working on or in the building during
construction, operational maintenance or demolition should ensure good
ventilation and wear Personal Protective Equipment including protection
against inhalation while using powdered material or when sanding, drilling,
cutting or otherwise disturbing or creating powdered material.
TREATED TIMBER
The design of this building includes provision for the inclusion of treated
timber within the structure. Dust or fumes from this material can be harmful.
Persons working on or in the building during construction, operational
maintenance or demolition should ensure good ventilation and wear
Personal Protective Equipment including protection against inhalation of
harmful material when sanding, drilling, cutting or using treated timber in
any way that may cause harmful material to be released. Do not burn
treated timber.
VOLATILE ORGANIC COMPOUNDS
Many types of glue, solvents, spray packs, paints, varnishes and some
cleaning materials and disinfectants have dangerous emissions. Areas
where these are used should be kept well ventilated while the material is
being used and for a period after installation. Personal Protective
Equipment may also be required. The manufacturer’s recommendations for
use must be carefully considered at all times.
SYNTHETIC MINERAL FIBRE
Fibreglass, rockwool, ceramic and other material used for thermal or sound
insulation may contain synthetic mineral fibre which may be harmful if
inhaled or if it comes in contact with the skin, eyes or other sensitive parts
or the body. Personal Protective Equipment including protection against
inhalation of harmful material should be used when installing, removing or
working near bulk insulation material.
TIMBER FLOORS
This building contains timber floors which have an applied finish. Areas
where finishes are applied should be kept well ventilated during sanding
and application and for a period after installation. Personal Protective
Equipment may also be required. The manufacturer’s recommendations for
use must be carefully considered at all times.
7. CONFINED SPACESEXCAVATION
Construction of this building and some maintenance on the building will
require excavation and installation of items within excavations. Where
practical, installation should be carried out using methods which do not
require workers to enter the excavation. Where this is not practical,
adequate support for the excavated area should be provided to prevent
collapse. Warning signs and barriers to prevent accidental or unauthorised
access to all excavations should be provided.
ENCLOSED SPACES
Enclosed spaces within this building may present a risk to persons entering
for construction, maintenance or any other purpose. The design
documentation calls for warning signs and barriers to unauthorised access.
These should be maintained throughout the life of the building. Where
workers are required to enter enclosed spaces, air testing equipment and
Personal Protective Equipment should be provided.
SMALL SPACES
Some small spaces within this building will require access by construction
or maintenance workers. The design documentation calls for warning signs
and barriers to unauthorised access. These should be maintained
throughout the life of the building. Where workers are required to enter
small spaces they should be scheduled so that access is for short periods.
Manual lifting and other manual activity should be restricted in small
spaces.
8. PUBLIC ACCESSPublic access to construction and demolition sites and to areas under
maintenance causes risk to workers and public. Warning signs and secure
barriers to unauthorised access should be provided. Where electrical
installations, excavations, plant or loose materials are present they should
be secured when not fully supervised.
9. OPERATIONAL USE OF BUILDINGThis building has been designed to requirements of the specific building
classification identified within the drawings. Where a change of use occurs
at a later date a further assessment of the workplace health and safety
issues should be undertaken, in accordance with the provisions of the Work
Health and Safety Act 2011 or subsequent replacement Act.
(Where the specific use of the building is not known at the time of the
completion of this report and a further assessment of the workplace health
and safety issues should be undertaken at the time of fit-out for the end-
user.)
10. OTHER HIGH RISK ACTIVITYAll electrical work should be carried out in accordance with Code of
Practice: Managing Electrical Risks at the Workplace, AS/NZ 3012 and all
licensing requirements.
All work using Plant should be carried out in accordance with Code of
Practice: Managing Risks of Plant at the Workplace.
All work should be carried out in accordance with Code of Practice:
Managing Noise and Preventing Hearing Loss at Work.
Due to the history of serious incidents it is recommended that particular
care be exercised when undertaking work involving steel construction and
concrete placement. All the above applies.
WORKPLACE HEALTH &
SAFETY REPORT
Compiled in accordace with Work Health and
Safety Act 2011.
IDENTIFIED HAZARD AREAS
1. FALLS, SLIPS, TRIPS
a) WORKING AT HEIGHTS
DURING CONSTRUCTION
Wherever possible, components for this building should be prefabricated
off-site or at ground level to minimise the risk of workers falling more than
two metres. However, construction of this building will require workers to be
working at heights where a fall in excess of two metres is possible and
injury is likely to result from such a fall. The builder should provide a
suitable barrier wherever a person is required to work in a situation where
falling more than two metres is a possibility.
DURING OPERATION OR MAINTENANCE
Cleaning and maintenance of windows, walls, roof or other components of
this building will require persons to be situated where a fall from a height in
excess of two metres is possible. Where this type of activity is required,
scaffolding, ladders or trestles should be used in accordance with relevant
codes of practice, regulations or legislation.
Cleaning and maintenance of windows, walls, roof or other components of
this building will require persons to be situated where a fall from a height in
excess of two metres is possible. Where this type of activity is required,
scaffolding, fall barriers or Personal Protective Equipment should be used in
accordance with relevant codes of practice, regulations or legislation.
Anchorage points for portable scaffold or fall arrest devices have been
included in the design for use by maintenance workers. Any persons
engaged to work on the building after completion of construction work
should be informed about the anchorage points.
PROPOSED DWELLING FOR
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
5 23
H120912I021012J151112K200314L260314
820
720
720
05-1
1afg
24-2
4afg
24-24SD
21-2
7 pa
nelif
t doo
r
21-24 panelift door
123456789
10 11 12 13
12345678 123
22-3
9 p
ane
lift d
oor
24-3
9SD
6,033 to wall
7,187 to wall
2,00
0
2,39
2
1,98
6
1,00
0
1,500
4,31
0
PROPOSED 3 STOREY + BASEMENT DWELLINGALL LEVELS T.B.C ON SITESITE COVERAGE - 41.60 %FLOOR SPACE RATIO - 1.10 F.S.R
VXO TO LOCALAUTHORITY GUIDELINES
PROPOSED CANALWALKWAY FINISHED
TO LOCAL AUTHORITYGUIDELINES
PROPOSED BASEMENT WITHGROUND FLOOR SLABMAX. 1000mm ABOVE NGL
MINOR FILL TO RL
SLAB RL- 1.300m
SLAB RL- 1.770m
900mm high
block ret. wall
600mm highblock ret. wall
BUILDING REFERENCE LINE - RL 3.230m
1200mm high alum. openpool fencing to side boundarydown embankment
1200mm highalum. openpool fencing to sideboundary
down embankment
15.6
53
112°1
8'0
0"
5.8
20
109
°04'5
5"
45.029 198°39'55"
12
.16
4290
°01'3
0"
12.1
64
29
2°4
4'4
0"
45.000
22°18'00"
Site
Benchm
ark
Nail in
Concrete
RL 3
.08 A
HD
WM
WA
TE
R M
ET
ER
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.06
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.10
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.24
SEWER MANHOLESL3.02
OD
HW
CPIT
3. 0
0
CP
IT
2xCO
MM
UN
ICAT
ION
S P
IT
ICV
CLIENT
3.01
3.07
2.94
2.93
3.08
3.2
1
3 16
3 15
3.03
1.21
1.21
1.21
295
302
298
304
3.12
3.13
3.22
3.26
315
309
3.2
2
3.2
3
317 3
14
1.5
0
1.7
5
2.0
0
2.2
52.5
0
2. 7
5
3.0
0
1.2
5
3.00
3.25
1. 2
5
1.5
0
1.7
5
2.0
0
2.2
5
2.5
0
2.7
5
3.0
0
EA
ST
WE
ST
SU
MMERBREEZESPMNE-SE
WIN
TE
RS
UN
AM
SUMMERSUNAM
SU
MM
ER
BRE
EZE
S
AM
S-S
E
SU M
ME
RST
OR
MS
WIN
TER
WIN
DSW- SW
SUMMER SUN PM
WINTERSUN
PM
SOUTH
TRUE NORTH
M.G.A.
Lot 4
7
VA
CA
NT
LOT
48
VA
CA
NT
LOT
28
2 ST
OR
EY
RE
ND
ER
ED
DW
ELLIN
G
C A
N A
L
CO
MM
ON
PR
OP
ER
TY
Site
Lot:
AL
AN
SU
LL
IVA
N &
AS
SO
CIA
TE
S P
/L T
AK
E N
O
SE
RV
ICE
S W
AR
NIN
G
IDE
NT
IFIC
AT
ION
SU
RV
EY
WA
RN
ING
THIS
CO
NTO
UR
AN
D F
EAT
UR
E S
UR
VE
Y, A
S P
RE
PAR
ED
TIT
LE
SE
AR
CH
WA
RN
ING
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TES
P/L
HA
S N
OT
CA
RR
IED
OU
T A
TIT
LE S
EA
RC
H F
OR
TH
IS S
UR
VE
Y.
CH
EC
KD
ER
M F
OR
EA
SE
ME
NT
S A
ND
EN
CU
MB
RA
NC
ES
.
RE
SP
ON
SIB
ILIT
Y F
OR
TH
E L
OC
AT
ION
OF
AN
Y N
ON
-VIS
IBL
E S
ER
VIC
E
BY
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TE
S P
/L, D
OE
S N
OT
GU
AR
AN
TE
E T
HE
LO
CAT
ION
OF
BO
UN
DA
RY
PE
GS
OR
FEN
CE
S. P
LEA
SE
CO
NTA
CT
THIS
OFF
ICE
FO
R A
QU
OTE
OR
FU
RT
HE
R A
DV
ICE
.
Str
ee
t /
Road
:
Sub
urb
:
Lo
cal A
uth
ority
:
Parish
:
UB
D R
ef:
on R
P/S
P:
Cou
nty
:
Are
a:
47
GT
P10
7352
CO
UN
CIL
OF
TH
E C
ITY
OF
GO
LD C
OA
ST
CO
OM
ER
AW
AR
D
-103
1sq
m
Serv
ice
s
Sew
era
ge
:
Sto
rmw
ate
r:
Wate
r:
Ele
ctri
city
:
Tele
ph
one:
Gas:
Yes
Yes
Yes
Ye
s (U
nderg
round)
No
t S
ighte
d
Not S
igh
ted
Road
:B
itum
en
Kerb
:Ye
s (M
ou
nta
ble
)
Foo
tpath
:N
o
Flo
od L
eve
l:N
/A
ED
GE
CLIF
F D
RIV
E
HO
PE
IS
LA
ND
PAV
ED
DR
IVE
WAY
TO
P O
F B
AN
K
CONCRETE TILT PANEL FENCE
RE
VE
TM
EN
T W
AL
L
050
mm
mm
100
mm
150
0 -
SC
ALE
IN M
ET
RE
S10
mm
20m
30
CHECKED
TK
SURVEYOR
CO
NT
OU
R &
DE
TA
ILS
UR
VE
Y1
:20
0 @
A3
CO
PY
RIG
HT
AL
AN
SU
LLIV
AN
& A
SS
OC
IAT
ES
PT
Y L
TD
, 20
12
c
PO
Box
385
2, B
urle
igh
Tow
n, Q
LD, 4
220
8/12
Ern
Har
ley
Driv
e, B
urle
igh
Hea
ds, Q
LD, 4
220
Ph
(07)
552
2 14
45, F
ax (
07)
5522
144
9M
ob 0
412
671
630,
Em
ail a
dmin
@as
urve
y.co
m.a
uA
BN
15
006
622
760
AL
AN
SU
LL
IVA
N&
Ass
oci
ate
s P
ty.
Ltd
.C
on
sulti
ng
Su
rve
yors
AU
ST
RA
LIA
N H
EIG
HT
DA
TU
MN
VID
E O
PM
1723
55 R
L2.6
3S
ITE
B.M
. N
AIL
IN
CO
NC
RL3
.08
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S
DRAWINGNUMBER
1/1
-
REVISION
SHEET
SCALE
LEVELDATUM
JOBNUMBER
DATE
1/5
/20
12
DRAWN
GB
CC
12
.35
21
12
.35
21
.01
Note
sT
HIS
PLA
N H
AS
BE
EN
PR
EP
AR
ED
FR
OM
FIE
LD
SU
RV
EY
AN
DE
XIS
ITIN
G R
EC
OR
DS
FO
R O
UR
CLIE
NT
S T
O D
ES
IGN
NE
WS
TR
UC
TU
RE
S O
N T
HIS
SIT
E A
ND
SH
OU
LD
NO
T B
E U
SE
D F
OR
AN
Y O
TH
ER
PU
RP
OS
E O
R B
Y A
NY
OT
HE
R P
ER
SO
NS
OR
CO
RP
OR
AT
ION
S W
ITH
OU
T W
RIT
TE
N A
PP
RO
VA
L F
RO
M A
LA
NS
UL
LIV
AN
& A
SS
OC
IAT
ES
P/L
. N
ON
-VIS
IBL
E S
ER
VIC
ES
HA
VE
NO
T B
EE
N P
LO
TT
ED
BU
T,
AR
E A
VA
ILA
BL
E F
RO
M T
HE
LO
CA
LA
UT
HO
RIT
Y O
R A
GE
NT
WH
ICH
HA
VE
LIM
ITIE
D A
ND
VA
RIE
DA
CC
UR
AC
Y. IT
IS
TH
E P
LA
N U
SE
RS
RE
SP
ON
SIB
ILIT
Y T
OA
CC
UR
AT
ELY
LO
CA
TE
AN
D/O
R E
XP
OS
E A
NY
NO
N-V
ISIB
LE
SE
RV
ICE
S A
ND
DE
TE
RM
INE
WH
ET
HE
R T
ITLE
EN
CU
MB
RA
NC
ES
WIL
L P
RE
VE
NT
OR
LIM
IT D
EV
ELO
PM
EN
T A
ND
TO
CH
EC
K O
N,
TH
E L
OC
AL
AU
TH
OR
ITY
'S D
EF
INIT
ION
OF
NA
TU
RA
L G
RO
UN
DLE
VE
L, P
RIO
R T
O C
ON
ST
RU
CT
ION
CO
MM
EN
CIN
G.
[SE
E W
AR
NIN
G N
OT
ES
ON
TH
E F
AC
E O
F P
LAN
FO
R M
OR
E D
ETA
ILS
]
flat 1:8 fall 1:4.7 fall 1:8 fall
to w
all
to s
tep
s
walkway
to w
all
to w
all
NOTES:* Discharge waste to connection point* Provide sediment control to site where req'd
* Meter box position T.B.C on site* All retaining walls by owner
* Discharge stormwater to TANK, where possible, all otherstormwater & overflow to kerb & channel
SITE PLAN - BASEMENT
SCALE 1:200 SHEET 5 OF 23
**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. &3.5.2. AS WELL AS ASNZS3500
* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THENTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.
** 1:5 MAX DRIVEWAY SLOPE TO LOCAL GOVERNMENTREQUIREMENTS AND STANDARDS **
................................
................................
................................
................................
2550mmCUT
FL 0.950mF.L
FILL
GL 0.650mG.L
appr
ox.
RAIN WATER STORAGE TANKS INACCORDANCE WITH THE QUEENSLANDDEVELOPMENT CODE - PART 4.2 & 4.3
MANDATORY RAINWATER TANK 3000L PERDUPLEX UNIT, 5000L PER SINGLEDETACHED DWELLING, FOR WC'S,
WASHING MACHINE COLD WATER TAPS &EXTERNAL TAPS. LOCATION TBC ON SITETO PROVIDE THE LESSER OF 100m² OR
HALF-ROOF CATCHMENT AREA, WITH 15LITRE FIRST FLUSH DIVERSION AS PERBUILDER. AUTO SWITCHING DEVICE OR
TRICKLE TOP-UP SYSTEM REQUIREDATTACHED TO TOWN WATER, WITH
BACKFLOW PREVENTION DEVICE. ALLTANKS TO BE MIN 450mm FROM SIDE OR
REAR BOUNDARY. TANKS OVER 2.4M HIGHTO BE MIN 1.5M FROM SIDE OR REAR
BOUNDARY. RELAXATION REQUIRED FORTANKS IN 6M FRONT SETBACK.
OVERFLOW TO BE CONNECTED TO LEGALPOINT OF DISCHARGE.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
6 23
H120912I021012J151112K200314L260314
1500
720
820
820
820
06-24afg 06-30afg
27-5
4sta
cker
27-4
5sta
cker
06-5
0afg
14-0
9alw
60-0
8afg
30-1
6afg
06-2
1aaw
06-2
1aaw
27-0
9alw
27-0
9alw
27-1
8afg
06-12aaw
27-09alw
57-1
2af
g
60-10afg
27-0
9alw
123456789
10 11 12 13 14 15 16 17 18
12345678
1 2 3 4 5 6 7 8 9 10 11
1 2 3
1
2
1 2 12
D.P
D.P
D.P D.P
D.P
D.P D.P
D.P D.P
D.P D.P D.P
8,121 to wall
2,00
0
5,033 to deck2,
104
1,03
8 to
sla
b
3,20
3 to
po
ol
5,988 to pool
1,00
0
3,00
0
9,849 to pier
2,686
2,000
1,43
7
PROPOSED 3 STOREY + BASEMENT DWELLINGALL LEVELS T.B.C ON SITESITE COVERAGE - 41.60 %FLOOR SPACE RATIO - 1.10 F.S.R
VXO TO LOCAL
AUTHORITY GUIDELINES
PROPOSED GATEHOUSE,SLAB RL 3.200m
BIN COLLECTIONENCLOSURE
SERVICE COURTSCREENING WALLS
PROPOSEDPOOL
FEATURE LOW WALL
W. LETTERBOX BUILT-IN& LASER CUT STAINLESS
STEEL STREET NUMBERS,TO FUTURE DETAIL
BIN COLLECTION
ENCLOSURE
TILED CONCRETE @NATURAL GROUND LEVEL,SLAB RL - 3.300m APPROX.
EXPOSED AGGREGATE PATH @NATURAL GROUND LEVELSLAB RL - 3.200m APPROX.
BUILDING REFERENCE LINE - RL 3.230m
MAINTAIN NATURALGROUND LEVELS
MAINTAIN NATURALGROUND LEVELS
MAINTAIN NATURALGROUND LEVELS
1200mm high alum. openpool fencing to side boundary
down embankment
1200mm high alum. openpool fencing to side boundarydown embankment
5,000L UNDERGROUND CONC.R/WATER TANK - T.B.C.
POOL SIDE CONC.DECK
WITH ASTRO TURF1m C'LEVERED
GARDEN BEDAS PER
PREVIOUSLANDSCAPEPLAN
15.6
53
112°1
8'0
0"
5.8
20
109
°04'5
5"
45.029 198°39'55"
12
.16
4290
°01'3
0"
12.1
64
29
2°4
4'4
0"
45.000
22°18'00"
Site
Benchm
ark
Nail in
Concrete
RL 3
.08 A
HD
WM
WA
TE
R M
ET
ER
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.06
STORMWATERPROPERTY PITSL3.10
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.24
SEWER MANHOLESL3.02
OD
HW
CPIT
3. 0
0
CP
IT
2xCO
MM
UN
ICAT
ION
S P
IT
ICV
CLIENT
3.01
3.07
2.94
2.93
3.08
3.2
1
3 16
3 15
3.03
1.21
1.21
1.21
295
302
298
304
3.12
3.13
3.22
3.26
315
309
3.2
2
3.2
3
317 3
14
1. 5
0
1. 7
5
2.0
0
2.2
52.5
0
2. 7
5
3.0
0
1.2
5
3.00
3.25
1. 2
5
1.5
0
1.7
5
2.0
0
2.2
5
2.5
0
2.7
5
3.0
0
EA
ST
WE
ST
SU
MMERBREEZESPMNE-SE
WIN
TE
RS
UN
AM
SUMMERSUNAM
SU
MM
ER
BRE
EZE
S
AM
S-S
E
SU M
ME
RST
OR
MS
WIN
TER
WIN
DSW- SW
SUMMER SUN PM
WINTERSUN
PM
SOUTH
TRUE NORTH
M.G.A.
Lot 4
7
VA
CA
NT
LOT
48
VA
CA
NT
LOT
28
2 ST
OR
EY
RE
ND
ER
ED
DW
ELLIN
G
C A
N A
L
CO
MM
ON
PR
OP
ER
TY
Site
Lot:
AL
AN
SU
LL
IVA
N &
AS
SO
CIA
TE
S P
/L T
AK
E N
O
SE
RV
ICE
S W
AR
NIN
G
IDE
NT
IFIC
AT
ION
SU
RV
EY
WA
RN
ING
THIS
CO
NTO
UR
AN
D F
EAT
UR
E S
UR
VE
Y, A
S P
RE
PAR
ED
TIT
LE
SE
AR
CH
WA
RN
ING
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TES
P/L
HA
S N
OT
CA
RR
IED
OU
T A
TIT
LE S
EA
RC
H F
OR
TH
IS S
UR
VE
Y.
CH
EC
KD
ER
M F
OR
EA
SE
ME
NT
S A
ND
EN
CU
MB
RA
NC
ES
.
RE
SP
ON
SIB
ILIT
Y F
OR
TH
E L
OC
AT
ION
OF
AN
Y N
ON
-VIS
IBL
E S
ER
VIC
E
BY
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TE
S P
/L, D
OE
S N
OT
GU
AR
AN
TE
E T
HE
LO
CAT
ION
OF
BO
UN
DA
RY
PE
GS
OR
FEN
CE
S. P
LEA
SE
CO
NTA
CT
THIS
OFF
ICE
FO
R A
QU
OTE
OR
FU
RT
HE
R A
DV
ICE
.
Str
ee
t /
Road
:
Sub
urb
:
Lo
cal A
uth
ority
:
Parish
:
UB
D R
ef:
on R
P/S
P:
Cou
nty
:
Are
a:
47
GT
P10
7352
CO
UN
CIL
OF
TH
E C
ITY
OF
GO
LD C
OA
ST
CO
OM
ER
AW
AR
D
-103
1sq
m
Serv
ice
s
Sew
era
ge
:
Sto
rmw
ate
r:
Wate
r:
Ele
ctri
city
:
Tele
ph
one:
Gas:
Yes
Yes
Yes
Ye
s (U
nderg
round)
No
t S
ighte
d
Not S
igh
ted
Road
:B
itum
en
Kerb
:Ye
s (M
ou
nta
ble
)
Foo
tpath
:N
o
Flo
od L
eve
l:N
/A
ED
GE
CLIF
F D
RIV
E
HO
PE
IS
LA
ND
PAV
ED
DR
IVE
WAY
TO
P O
F B
AN
K
CONCRETE TILT PANEL FENCE
RE
VE
TM
EN
T W
AL
L
050
mm
mm
100
mm
150
0 -
SC
ALE
IN M
ET
RE
S10
mm
20m
30
CHECKED
TK
SURVEYOR
CO
NT
OU
R &
DE
TA
ILS
UR
VE
Y1
:20
0 @
A3
CO
PY
RIG
HT
AL
AN
SU
LLIV
AN
& A
SS
OC
IAT
ES
PT
Y L
TD
, 20
12
c
PO
Box
385
2, B
urle
igh
Tow
n, Q
LD, 4
220
8/12
Ern
Har
ley
Driv
e, B
urle
igh
Hea
ds, Q
LD, 4
220
Ph
(07)
552
2 14
45, F
ax (
07)
5522
144
9M
ob 0
412
671
630,
Em
ail a
dmin
@as
urve
y.co
m.a
uA
BN
15
006
622
760
AL
AN
SU
LL
IVA
N&
Ass
oci
ate
s P
ty.
Ltd
.C
on
sulti
ng
Su
rve
yors
AU
ST
RA
LIA
N H
EIG
HT
DA
TU
MN
VID
E O
PM
1723
55 R
L2.6
3S
ITE
B.M
. N
AIL
IN
CO
NC
RL3
.08
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S
DRAWINGNUMBER
1/1
-
REVISION
SHEET
SCALE
LEVELDATUM
JOBNUMBER
DATE
1/5
/20
12
DRAWN
GB
CC
12
.35
21
12
.35
21
.01
Note
sT
HIS
PLA
N H
AS
BE
EN
PR
EP
AR
ED
FR
OM
FIE
LD
SU
RV
EY
AN
DE
XIS
ITIN
G R
EC
OR
DS
FO
R O
UR
CLIE
NT
S T
O D
ES
IGN
NE
WS
TR
UC
TU
RE
S O
N T
HIS
SIT
E A
ND
SH
OU
LD
NO
T B
E U
SE
D F
OR
AN
Y O
TH
ER
PU
RP
OS
E O
R B
Y A
NY
OT
HE
R P
ER
SO
NS
OR
CO
RP
OR
AT
ION
S W
ITH
OU
T W
RIT
TE
N A
PP
RO
VA
L F
RO
M A
LA
NS
UL
LIV
AN
& A
SS
OC
IAT
ES
P/L
. N
ON
-VIS
IBL
E S
ER
VIC
ES
HA
VE
NO
T B
EE
N P
LO
TT
ED
BU
T,
AR
E A
VA
ILA
BL
E F
RO
M T
HE
LO
CA
LA
UT
HO
RIT
Y O
R A
GE
NT
WH
ICH
HA
VE
LIM
ITIE
D A
ND
VA
RIE
DA
CC
UR
AC
Y. IT
IS
TH
E P
LA
N U
SE
RS
RE
SP
ON
SIB
ILIT
Y T
OA
CC
UR
AT
ELY
LO
CA
TE
AN
D/O
R E
XP
OS
E A
NY
NO
N-V
ISIB
LE
SE
RV
ICE
S A
ND
DE
TE
RM
INE
WH
ET
HE
R T
ITLE
EN
CU
MB
RA
NC
ES
WIL
L P
RE
VE
NT
OR
LIM
IT D
EV
ELO
PM
EN
T A
ND
TO
CH
EC
K O
N,
TH
E L
OC
AL
AU
TH
OR
ITY
'S D
EF
INIT
ION
OF
NA
TU
RA
L G
RO
UN
DLE
VE
L, P
RIO
R T
O C
ON
ST
RU
CT
ION
CO
MM
EN
CIN
G.
[SE
E W
AR
NIN
G N
OT
ES
ON
TH
E F
AC
E O
F P
LAN
FO
R M
OR
E D
ETA
ILS
]
flat 1:8 fall
gate
gate
27-4
5 c
usto
m s
tack
er (
XO
X)
gate
gate
gate
tap
tap
tap
tap
to w
all
to w
all
to w
all
to s
tep
s
to conc. deck
to c
on
c. d
ec
k
NOTES:* Discharge waste to connection point* Provide sediment control to site where req'd
* Meter box position T.B.C on site* All retaining walls by owner
* Discharge stormwater to TANK, where possible, all otherstormwater & overflow to kerb & channel
SITE PLAN - GROUND FLOOR
SCALE 1:200 SHEET 6 OF 23
**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. &3.5.2. AS WELL AS ASNZS3500
* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THENTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.
** 1:5 MAX DRIVEWAY SLOPE TO LOCAL GOVERNMENTREQUIREMENTS AND STANDARDS **
................................
................................
................................
................................
CUT
FL 3.770mF.L
FILL
NATURALG.L
appr
ox.
RAIN WATER STORAGE TANKS INACCORDANCE WITH THE QUEENSLANDDEVELOPMENT CODE - PART 4.2 & 4.3
MANDATORY RAINWATER TANK 3000L PERDUPLEX UNIT, 5000L PER SINGLEDETACHED DWELLING, FOR WC'S,
WASHING MACHINE COLD WATER TAPS &EXTERNAL TAPS. LOCATION TBC ON SITETO PROVIDE THE LESSER OF 100m² OR
HALF-ROOF CATCHMENT AREA, WITH 15LITRE FIRST FLUSH DIVERSION AS PERBUILDER. AUTO SWITCHING DEVICE OR
TRICKLE TOP-UP SYSTEM REQUIREDATTACHED TO TOWN WATER, WITH
BACKFLOW PREVENTION DEVICE. ALLTANKS TO BE MIN 450mm FROM SIDE OR
REAR BOUNDARY. TANKS OVER 2.4M HIGHTO BE MIN 1.5M FROM SIDE OR REAR
BOUNDARY. RELAXATION REQUIRED FORTANKS IN 6M FRONT SETBACK.
OVERFLOW TO BE CONNECTED TO LEGALPOINT OF DISCHARGE.
PROVIDE 1200mm HIGH FG POOL FENCE,
ALONG TOP OF EXISTING REVETMENTWALL, AS PER SANC. COVE GUIDELINES
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
7 23
H120912I021012J151112K200314L260314
60-0
8afg
30-1
6afg
57-1
2af
g
60-10afg
1000
ham
per
920
1000
ham
per
820
1000
ham
per
1000
ham
per
100
0
ham
per
920
920
820
920
1000hamper920
1000
ham
per
920
1000
ham
per
1000hamper
20-2
7af
g
24-0
9alw
24-3
3sta
cker
24-0
9alw
24-0
9alw
24-0
9alw
24-3
6sta
cker
24-2
1SD21
-27a
lw
06-30aaw06-15aaw
06-30aaw06-15aaw
20-27afg
06-30aaw
12-0
9alw
12-09alw12-09alw06-15aaw
24-0
9alw
24-0
9alw
24-1
8afg
06-30aaw
12-18alw
9 10 11 12 13 14 15 16 17 18
D.P
D.P
D.P D.P
D.P D.P
D.P D.P D.P
1 2 3 4 5 6
D.P
D.P
9,848 to pier/deck
2,00
0 to
wal
l
1,36
0 to
fas
cia
1,76
6 to
fas
cia
2,43
6 to
pi e
r
2,10
4 to
wal
l
1,43
4 to
fas
cia
7,306 to pier
2,00
0 to
wal
l
PROPOSED 3 STOREY + BASEMENT DWELLINGALL LEVELS T.B.C ON SITESITE COVERAGE - 41.60 %FLOOR SPACE RATIO - 1.10 F.S.R
roof
fall
roof fall
roof
fall
15.6
53
112°1
8'0
0"
5.8
20
109
°04'5
5"
45.029 198°39'55"
12
.16
4290
°01'3
0"
12.1
64
29
2°4
4'4
0"
45.000
22°18'00"
Site
Benchm
ark
Nail in
Concrete
RL 3
.08 A
HD
WM
WA
TE
R M
ET
ER
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.06
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.10
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.24
SEWER MANHOLESL3.02
OD
HW
CPIT
3. 0
0
CP
IT
2xCO
MM
UN
ICAT
ION
S P
IT
ICV
CLIENT
3.01
3.07
2.94
2.93
3.08
3.2
1
3 16
3 15
3.03
1.21
1.21
1.21
295
302
298
304
3.12
3.13
3.22
3.26
315
309
3.2
2
3.2
3
317 3
14
1. 5
0
1. 7
5
2.0
0
2.2
52.5
0
2. 7
5
3.0
0
1.2
5
3.00
3.25
1. 2
5
1.5
0
1.7
5
2.0
0
2.2
5
2.5
0
2.7
5
3.0
0
EA
ST
WE
ST
SU
MMERBREEZESPMNE-SE
WIN
TE
RS
UN
AM
SUMMERSUNAM
SU
MM
ER
BRE
EZE
S
AM
S-S
E
SU M
ME
RST
OR
MS
WIN
TER
WIN
DSW- SW
SUMMER SUN PM
WINTERSUN
PM
SOUTH
TRUE NORTH
M.G.A.
Lot 4
7
VA
CA
NT
LOT
48
VA
CA
NT
LOT
28
2 ST
OR
EY
RE
ND
ER
ED
DW
ELLIN
G
C A
N A
L
CO
MM
ON
PR
OP
ER
TY
Site
Lot:
AL
AN
SU
LL
IVA
N &
AS
SO
CIA
TE
S P
/L T
AK
E N
O
SE
RV
ICE
S W
AR
NIN
G
IDE
NT
IFIC
AT
ION
SU
RV
EY
WA
RN
ING
THIS
CO
NTO
UR
AN
D F
EAT
UR
E S
UR
VE
Y, A
S P
RE
PAR
ED
TIT
LE
SE
AR
CH
WA
RN
ING
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TES
P/L
HA
S N
OT
CA
RR
IED
OU
T A
TIT
LE S
EA
RC
H F
OR
TH
IS S
UR
VE
Y.
CH
EC
KD
ER
M F
OR
EA
SE
ME
NT
S A
ND
EN
CU
MB
RA
NC
ES
.
RE
SP
ON
SIB
ILIT
Y F
OR
TH
E L
OC
AT
ION
OF
AN
Y N
ON
-VIS
IBL
E S
ER
VIC
E
BY
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TE
S P
/L, D
OE
S N
OT
GU
AR
AN
TE
E T
HE
LO
CAT
ION
OF
BO
UN
DA
RY
PE
GS
OR
FEN
CE
S. P
LEA
SE
CO
NTA
CT
THIS
OFF
ICE
FO
R A
QU
OTE
OR
FU
RT
HE
R A
DV
ICE
.
Str
ee
t /
Road
:
Sub
urb
:
Lo
cal A
uth
ority
:
Parish
:
UB
D R
ef:
on R
P/S
P:
Cou
nty
:
Are
a:
47
GT
P10
7352
CO
UN
CIL
OF
TH
E C
ITY
OF
GO
LD C
OA
ST
CO
OM
ER
AW
AR
D
-103
1sq
m
Serv
ice
s
Sew
era
ge
:
Sto
rmw
ate
r:
Wate
r:
Ele
ctri
city
:
Tele
ph
one:
Gas:
Yes
Yes
Yes
Ye
s (U
nderg
round)
No
t S
ighte
d
Not S
igh
ted
Road
:B
itum
en
Kerb
:Ye
s (M
ou
nta
ble
)
Foo
tpath
:N
o
Flo
od L
eve
l:N
/A
ED
GE
CLIF
F D
RIV
E
HO
PE
IS
LA
ND
PAV
ED
DR
IVE
WAY
TO
P O
F B
AN
K
CONCRETE TILT PANEL FENCE
RE
VE
TM
EN
T W
AL
L
050
mm
mm
100
mm
150
0 -
SC
ALE
IN M
ET
RE
S10
mm
20m
30
CHECKED
TK
SURVEYOR
CO
NT
OU
R &
DE
TA
ILS
UR
VE
Y1
:20
0 @
A3
CO
PY
RIG
HT
AL
AN
SU
LLIV
AN
& A
SS
OC
IAT
ES
PT
Y L
TD
, 20
12
c
PO
Box
385
2, B
urle
igh
Tow
n, Q
LD, 4
220
8/12
Ern
Har
ley
Driv
e, B
urle
igh
Hea
ds, Q
LD, 4
220
Ph
(07)
552
2 14
45, F
ax (
07)
5522
144
9M
ob 0
412
671
630,
Em
ail a
dmin
@as
urve
y.co
m.a
uA
BN
15
006
622
760
AL
AN
SU
LL
IVA
N&
Ass
oci
ate
s P
ty.
Ltd
.C
on
sulti
ng
Su
rve
yors
AU
ST
RA
LIA
N H
EIG
HT
DA
TU
MN
VID
E O
PM
1723
55 R
L2.6
3S
ITE
B.M
. N
AIL
IN
CO
NC
RL3
.08
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S
DRAWINGNUMBER
1/1
-
REVISION
SHEET
SCALE
LEVELDATUM
JOBNUMBER
DATE
1/5
/20
12
DRAWN
GB
CC
12
.35
21
12
.35
21
.01
Note
sT
HIS
PLA
N H
AS
BE
EN
PR
EP
AR
ED
FR
OM
FIE
LD
SU
RV
EY
AN
DE
XIS
ITIN
G R
EC
OR
DS
FO
R O
UR
CLIE
NT
S T
O D
ES
IGN
NE
WS
TR
UC
TU
RE
S O
N T
HIS
SIT
E A
ND
SH
OU
LD
NO
T B
E U
SE
D F
OR
AN
Y O
TH
ER
PU
RP
OS
E O
R B
Y A
NY
OT
HE
R P
ER
SO
NS
OR
CO
RP
OR
AT
ION
S W
ITH
OU
T W
RIT
TE
N A
PP
RO
VA
L F
RO
M A
LA
NS
UL
LIV
AN
& A
SS
OC
IAT
ES
P/L
. N
ON
-VIS
IBL
E S
ER
VIC
ES
HA
VE
NO
T B
EE
N P
LO
TT
ED
BU
T,
AR
E A
VA
ILA
BL
E F
RO
M T
HE
LO
CA
LA
UT
HO
RIT
Y O
R A
GE
NT
WH
ICH
HA
VE
LIM
ITIE
D A
ND
VA
RIE
DA
CC
UR
AC
Y. IT
IS
TH
E P
LA
N U
SE
RS
RE
SP
ON
SIB
ILIT
Y T
OA
CC
UR
AT
ELY
LO
CA
TE
AN
D/O
R E
XP
OS
E A
NY
NO
N-V
ISIB
LE
SE
RV
ICE
S A
ND
DE
TE
RM
INE
WH
ET
HE
R T
ITLE
EN
CU
MB
RA
NC
ES
WIL
L P
RE
VE
NT
OR
LIM
IT D
EV
ELO
PM
EN
T A
ND
TO
CH
EC
K O
N,
TH
E L
OC
AL
AU
TH
OR
ITY
'S D
EF
INIT
ION
OF
NA
TU
RA
L G
RO
UN
DLE
VE
L, P
RIO
R T
O C
ON
ST
RU
CT
ION
CO
MM
EN
CIN
G.
[SE
E W
AR
NIN
G N
OT
ES
ON
TH
E F
AC
E O
F P
LAN
FO
R M
OR
E D
ETA
ILS
]
NOTES:* Discharge waste to connection point* Provide sediment control to site where req'd
* Meter box position T.B.C on site* All retaining walls by owner
* Discharge stormwater to TANK, where possible, all otherstormwater & overflow to kerb & channel
SITE PLAN - FIRST FLOOR
SCALE 1:200 SHEET 7 OF 23
**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. &3.5.2. AS WELL AS ASNZS3500
* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THENTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.
** 1:5 MAX DRIVEWAY SLOPE TO LOCAL GOVERNMENTREQUIREMENTS AND STANDARDS **
................................
................................
................................
................................
CUT
FL 7.290mF.L
FILL
G.L
appr
ox.
RAIN WATER STORAGE TANKS INACCORDANCE WITH THE QUEENSLANDDEVELOPMENT CODE - PART 4.2 & 4.3
MANDATORY RAINWATER TANK 3000L PERDUPLEX UNIT, 5000L PER SINGLEDETACHED DWELLING, FOR WC'S,
WASHING MACHINE COLD WATER TAPS &EXTERNAL TAPS. LOCATION TBC ON SITETO PROVIDE THE LESSER OF 100m² OR
HALF-ROOF CATCHMENT AREA, WITH 15LITRE FIRST FLUSH DIVERSION AS PERBUILDER. AUTO SWITCHING DEVICE OR
TRICKLE TOP-UP SYSTEM REQUIREDATTACHED TO TOWN WATER, WITH
BACKFLOW PREVENTION DEVICE. ALLTANKS TO BE MIN 450mm FROM SIDE OR
REAR BOUNDARY. TANKS OVER 2.4M HIGHTO BE MIN 1.5M FROM SIDE OR REAR
BOUNDARY. RELAXATION REQUIRED FORTANKS IN 6M FRONT SETBACK.
OVERFLOW TO BE CONNECTED TO LEGALPOINT OF DISCHARGE.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
8 23
H120912I021012J151112K200314L260314
1200
ham
per
920
920
12-1
2afg
12-1
0afg
24-5
4sta
cker
18-2
7alw
06-30aaw
06-30aaw12-09alw
06-15aaw
12-18afg 12-27afg 12-27afg
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
D.P D.P
D.P
18-2
7alw
D.P
D.P
D.P06-30aaw
06-2
4aaw
06-2
4afg
1,43
4 to
fas
cia
1,76
6 to
fas
cia
1,36
0 to
fas
cia
7,306 to wall
4,51
8 to
wal
l
3,84
8 to
fas
cia
4,13
0 to
wal
l
8,869 to fascia
9,850 to pier/deck
PROPOSED 3 STOREY + BASEMENT DWELLINGALL LEVELS T.B.C ON SITESITE COVERAGE - 41.60 %FLOOR SPACE RATIO - 1.10 F.S.R
roof
fall
roof
fall
roof
fall
roof
fall
roof
fal
l
roo
f fal
l
15.6
53
112°1
8'0
0"
5.8
20
109
°04'5
5"
45.029 198°39'55"
12
.16
4290
°01'3
0"
12.1
64
29
2°4
4'4
0"
45.000
22°18'00"
Site
Benchm
ark
Nail in
Concrete
RL 3
.08 A
HD
WM
WA
TE
R M
ET
ER
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.06
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.10
ST
OR
MW
AT
ER
PR
OP
ER
TY
PIT
SL3.24
SEWER MANHOLESL3.02
OD
HW
CPIT
3. 0
0
CP
IT
2xCO
MM
UN
ICAT
ION
S P
IT
ICV
CLIENT
3.01
3.07
2.94
2.93
3.08
3.2
1
3 16
3 15
3.03
1.21
1.21
1.21
295
302
298
304
3.12
3.13
3.22
3.26
315
309
3.2
2
3.2
3
317 3
14
1. 5
0
1. 7
5
2.0
0
2.2
52.5
0
2. 7
5
3.0
0
1.2
5
3.00
3.25
1. 2
5
1.5
0
1.7
5
2.0
0
2.2
5
2.5
0
2.7
5
3.0
0
EA
ST
WE
ST
SU
MMERBREEZESPMNE-SE
WIN
TE
RS
UN
AM
SUMMERSUNAM
SU
MM
ER
BRE
EZE
S
AM
S-S
E
SU M
ME
RST
OR
MS
WIN
TER
WIN
DSW- SW
SUMMER SUN PM
WINTERSUN
PM
SOUTH
TRUE NORTH
M.G.A.
Lot 4
7
VA
CA
NT
LOT
48
VA
CA
NT
LOT
28
2 ST
OR
EY
RE
ND
ER
ED
DW
ELLIN
G
C A
N A
L
CO
MM
ON
PR
OP
ER
TY
Site
Lot:
AL
AN
SU
LL
IVA
N &
AS
SO
CIA
TE
S P
/L T
AK
E N
O
SE
RV
ICE
S W
AR
NIN
G
IDE
NT
IFIC
AT
ION
SU
RV
EY
WA
RN
ING
THIS
CO
NTO
UR
AN
D F
EAT
UR
E S
UR
VE
Y, A
S P
RE
PAR
ED
TIT
LE
SE
AR
CH
WA
RN
ING
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TES
P/L
HA
S N
OT
CA
RR
IED
OU
T A
TIT
LE S
EA
RC
H F
OR
TH
IS S
UR
VE
Y.
CH
EC
KD
ER
M F
OR
EA
SE
ME
NT
S A
ND
EN
CU
MB
RA
NC
ES
.
RE
SP
ON
SIB
ILIT
Y F
OR
TH
E L
OC
AT
ION
OF
AN
Y N
ON
-VIS
IBL
E S
ER
VIC
E
BY
ALA
N S
ULL
IVA
N &
AS
SO
CIA
TE
S P
/L, D
OE
S N
OT
GU
AR
AN
TE
E T
HE
LO
CAT
ION
OF
BO
UN
DA
RY
PE
GS
OR
FEN
CE
S. P
LEA
SE
CO
NTA
CT
THIS
OFF
ICE
FO
R A
QU
OTE
OR
FU
RT
HE
R A
DV
ICE
.
Str
ee
t /
Road
:
Sub
urb
:
Lo
cal A
uth
ority
:
Parish
:
UB
D R
ef:
on R
P/S
P:
Cou
nty
:
Are
a:
47
GT
P10
7352
CO
UN
CIL
OF
TH
E C
ITY
OF
GO
LD C
OA
ST
CO
OM
ER
AW
AR
D
-103
1sq
m
Serv
ice
s
Sew
era
ge
:
Sto
rmw
ate
r:
Wate
r:
Ele
ctri
city
:
Tele
ph
one:
Gas:
Yes
Yes
Yes
Ye
s (U
nderg
round)
No
t S
ighte
d
Not S
igh
ted
Road
:B
itum
en
Kerb
:Ye
s (M
ou
nta
ble
)
Foo
tpath
:N
o
Flo
od L
eve
l:N
/A
ED
GE
CLIF
F D
RIV
E
HO
PE
IS
LA
ND
PAV
ED
DR
IVE
WAY
TO
P O
F B
AN
K
CONCRETE TILT PANEL FENCE
RE
VE
TM
EN
T W
AL
L
050
mm
mm
100
mm
150
0 -
SC
ALE
IN M
ET
RE
S10
mm
20m
30
CHECKED
TK
SURVEYOR
CO
NT
OU
R &
DE
TA
ILS
UR
VE
Y1
:20
0 @
A3
CO
PY
RIG
HT
AL
AN
SU
LLIV
AN
& A
SS
OC
IAT
ES
PT
Y L
TD
, 20
12
c
PO
Box
385
2, B
urle
igh
Tow
n, Q
LD, 4
220
8/12
Ern
Har
ley
Driv
e, B
urle
igh
Hea
ds, Q
LD, 4
220
Ph
(07)
552
2 14
45, F
ax (
07)
5522
144
9M
ob 0
412
671
630,
Em
ail a
dmin
@as
urve
y.co
m.a
uA
BN
15
006
622
760
AL
AN
SU
LL
IVA
N&
Ass
oci
ate
s P
ty.
Ltd
.C
on
sulti
ng
Su
rve
yors
AU
ST
RA
LIA
N H
EIG
HT
DA
TU
MN
VID
E O
PM
1723
55 R
L2.6
3S
ITE
B.M
. N
AIL
IN
CO
NC
RL3
.08
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S
DRAWINGNUMBER
1/1
-
REVISION
SHEET
SCALE
LEVELDATUM
JOBNUMBER
DATE
1/5
/20
12
DRAWN
GB
CC
12
.35
21
12
.35
21
.01
Note
sT
HIS
PLA
N H
AS
BE
EN
PR
EP
AR
ED
FR
OM
FIE
LD
SU
RV
EY
AN
DE
XIS
ITIN
G R
EC
OR
DS
FO
R O
UR
CLIE
NT
S T
O D
ES
IGN
NE
WS
TR
UC
TU
RE
S O
N T
HIS
SIT
E A
ND
SH
OU
LD
NO
T B
E U
SE
D F
OR
AN
Y O
TH
ER
PU
RP
OS
E O
R B
Y A
NY
OT
HE
R P
ER
SO
NS
OR
CO
RP
OR
AT
ION
S W
ITH
OU
T W
RIT
TE
N A
PP
RO
VA
L F
RO
M A
LA
NS
UL
LIV
AN
& A
SS
OC
IAT
ES
P/L
. N
ON
-VIS
IBL
E S
ER
VIC
ES
HA
VE
NO
T B
EE
N P
LO
TT
ED
BU
T,
AR
E A
VA
ILA
BL
E F
RO
M T
HE
LO
CA
LA
UT
HO
RIT
Y O
R A
GE
NT
WH
ICH
HA
VE
LIM
ITIE
D A
ND
VA
RIE
DA
CC
UR
AC
Y. IT
IS
TH
E P
LA
N U
SE
RS
RE
SP
ON
SIB
ILIT
Y T
OA
CC
UR
AT
ELY
LO
CA
TE
AN
D/O
R E
XP
OS
E A
NY
NO
N-V
ISIB
LE
SE
RV
ICE
S A
ND
DE
TE
RM
INE
WH
ET
HE
R T
ITLE
EN
CU
MB
RA
NC
ES
WIL
L P
RE
VE
NT
OR
LIM
IT D
EV
ELO
PM
EN
T A
ND
TO
CH
EC
K O
N,
TH
E L
OC
AL
AU
TH
OR
ITY
'S D
EF
INIT
ION
OF
NA
TU
RA
L G
RO
UN
DLE
VE
L, P
RIO
R T
O C
ON
ST
RU
CT
ION
CO
MM
EN
CIN
G.
[SE
E W
AR
NIN
G N
OT
ES
ON
TH
E F
AC
E O
F P
LAN
FO
R M
OR
E D
ETA
ILS
]
NOTES:* Discharge waste to connection point* Provide sediment control to site where req'd
* Meter box position T.B.C on site* All retaining walls by owner
* Discharge stormwater to TANK, where possible, all otherstormwater & overflow to kerb & channel
SITE PLAN - SECOND FLOOR
SCALE 1:200 SHEET 8 OF 23
**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. &3.5.2. AS WELL AS ASNZS3500
* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THENTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.
** 1:5 MAX DRIVEWAY SLOPE TO LOCAL GOVERNMENTREQUIREMENTS AND STANDARDS **
................................
................................
................................
................................
CUT
FL 10.510mF.L
FILL
G.L
appr
ox.
RAIN WATER STORAGE TANKS INACCORDANCE WITH THE QUEENSLANDDEVELOPMENT CODE - PART 4.2 & 4.3
MANDATORY RAINWATER TANK 3000L PERDUPLEX UNIT, 5000L PER SINGLEDETACHED DWELLING, FOR WC'S,
WASHING MACHINE COLD WATER TAPS &EXTERNAL TAPS. LOCATION TBC ON SITETO PROVIDE THE LESSER OF 100m² OR
HALF-ROOF CATCHMENT AREA, WITH 15LITRE FIRST FLUSH DIVERSION AS PERBUILDER. AUTO SWITCHING DEVICE OR
TRICKLE TOP-UP SYSTEM REQUIREDATTACHED TO TOWN WATER, WITH
BACKFLOW PREVENTION DEVICE. ALLTANKS TO BE MIN 450mm FROM SIDE OR
REAR BOUNDARY. TANKS OVER 2.4M HIGHTO BE MIN 1.5M FROM SIDE OR REAR
BOUNDARY. RELAXATION REQUIRED FORTANKS IN 6M FRONT SETBACK.
OVERFLOW TO BE CONNECTED TO LEGALPOINT OF DISCHARGE.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
9 23
H120912I021012J151112K200314L260314
820
720
720
05-1
1afg
24-2
4afg
24-24SD
21-2
7 pa
nelif
t doo
r
21-24 panelift door
123456789
10 11 12 13
win
ew
ine
DWPROV
beer
beer
ice
12345678 123
22-3
9 pa
nelif
t doo
r
24-3
9SD
1,190 2,000 8,250 2,000300
190 9,630 5,400 900 5,500190
2,810190
3,000
6,560 3,820190
17,610 190
190650 1,100 600 4,070
19021,430 190
300
190
2,32
019
030
040
02,
880
400
10,0
001,
200
190
500
2,60
02,
600
2,60
02,
600
1,10
05,
400
100
190
190
17,5
0019
0
1903,130 2,590
1901,740 2,600 2,600 2,600 2,600 2,600 1,000
190300 2,800
3002,700
3001,810 190
190 60 5,210 190 1,800190
600 15,740190
2,910 190
1904,810
1904,010
19018,840
190
190
4,31
019
03,
910
370
1,35
019
060
1,20
019
01,
20060
190
4,58
019
0
190
8,41
019
02,
400
190
1,84
019
04,
580
190
1,150 2,140 6,100 15,930 3,100 3,300 2,000
1,00
02,
700
10,6
804,
500
1,30
0
31,420
3,690 6,690 20,990
1,150 19060
1,200 2,400 4,200 190 6,790 300 4,900 300 3,450 190 3,100
1,00
04,
500
6,01
03,
000
4,67
0
19,1
80
190
5,55
030
06,
900
900
3,85
019
0
190 1,160 1,000 190 2,460 190 1,420 190 2,400 190
B18
B18
A18
A18
C19
C19
D19
D19
E20
E20
F20
F20
G21
G21
H21
H21
J18
J18
K18
K18
Line of ground floor over
FG window inspill edge face
Wine racking & climatecontrol system tomanufacturers specs.
Pond above
21-10 customcavity sliding
door
Allowance for Remco pool cover,installed to manufacturers specs.Allowance for Remco pool cover,installed to manufacturers specs.
Feature stoneworkto LIFT SHAFT
Wall hung vanitywith concealedmirror cabinet above
Concealed cistern
Steam room, installedto manufacturers /builders specs.
900 x 300 Rendered Conc.pier, as per engineers spec.900 x 300 Rendered Conc.pier, as per engineers spec.
900 x 300 Rendered Conc.pier, as per engineers spec.
strip drainFW
1200
mm
hig
hba
r to
p
benc
h
WINE CELLARL
INE
N
LIFT
BAR
VESTIBULE
STORAGE
BASEMENTCARPARKING
DRIVEWAY
VXO to G.C.C.C &A.R.C specifications
flat 1:8 fall 1:4.7 fall 1:8 fall
pool
she
ll
pool
she
ll
SPA
LAPPOOL
pool
she
ll
gatehouseabove
190mm blockwork retaining walls
POOLPUMPROOM
STORE
800m
m h
igh
ret.
wal
l
STEAMROOM
SLAB RL - 0.950m A.H.D
BF
-W01
BF
-W02
BF
-W03
1 2 3 4 5
6
7
8
910
NOTE: SEE SHEETS 22 & 23 FORWINDOW/DOOR SCHEDULE DETAILS
Basement drainage & sump detailsto hydraulic engineers specs.,
grade slab to drains accordingly
ASTROTURF
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
BASEMENT FLOOR PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
10 23
H120912I021012J151112K200314L260314
1500
720
820
820
820
06-24afg 06-30afg
27-5
4sta
cker
27-4
5sta
cker
06-5
0afg
14-0
9alw
60-0
8afg
30-1
6afg
06-2
1aaw
06-2
1aaw
27-0
9alw
27-0
9alw
27-1
8afg
06-12aaw
27-09alw
57-1
2afg
60-10afg27
-09a
lw
123456789
10 11 12 13 14 15 16 17 18
12345678
1 2 3 4 5 6 7 8 9 10 11
1 2 3
1
2
1 2 12
W.M
.P
RO
V
DWPROV
wine wine
win
ew
ine
DW
PR
OV
W.M
.P
RO
V
win
ew
ine
beer
beer
beer beeric
e
D.P
D.P
D.P D.P
D.P
D.P D.P
D.P D.P
D.P D.P D.P
B18
B18
A18
A18
C19
C19
D19
D19
E20
E20
F20
F20
G21
G21
H21
H21
J18
J18
K18
K18
2506,000
902,130 90 1,000
270700 1,200 3,300 1,200
2505,610 390 1,500 4,700
3501,000 1,800 7,880
2502,100 3,900
902,130 90 7,670
2507,500 850 2,850 1,000
2,300190
4,010 2,630250
12,730270
5,920250
6,025200
925 2,850300
190
4,23
01,
720
2,30
035
04,
530
190
250
5,10
060
0902,
600
190
1,49
025
01,
200
190
1,20
035
04,
420
250
1,00
025
05,
520
270
2,80
02,
350
190
1,84
019
09060
03,
830
250
250
2,76
090
2,14
090
1,44
027
02,
850
1,15
090
1,00
090
4,41
025
02,
300
250 60
01,
560
1,50
07,
740
60090
5,29
025
0
250 60
01,
400
60090
880
907,
130
902,
210
904,
200
250
2,140250
2,910 90520
90 1,99090
2,40090
1,70090
7,660250
2,000 1,990 2,035 200 1,075 2,700 300 1,810 190 1,000
2501,200 2,400
2501,200
160 1901,800 190
35090 1,800
600 90 51090 2,660 270 5,920
2502,995 3,030
200
2501,320
3001,820 6,290
2705,920
250
350 1,000 1,450 6,490 1,740 6,690 250 2,620 90 790 90 5,700 250 1,200 4,410 1,890 850 2,850 1,000
250 5,600 250 3,870 250600
1,000 1,060 5,000 250 2,010 1,190
1,00
0
1,00
01,
300
3,000 5,440 2,140 6,100 3,870 8,160 3,200 1,000 2,800 300 2,700 300 3,000
650
160 2,690 8,180 6,690 9,790 1,200 4,410 1,890 850 2,850 1,000
1,610 1,740 250 2,01090 620
90 3,190 90 2,130 90 8,870 250 7,300 2,700 300 700
1,01
21,
000
1,00
05,
790
3,04
01,
490
3,19
04,
670
1,00
01,
458
1,01
21,
000
1,00
05,
790
250
2,60
019
01,
490
250
2,59
090
1025
04,
670
1,00
01,
458
5,50
06,
880
5,50
095
0
1,00
02,
850
550
2,88
040
010
,000
2,15
0
1,00
02,
850
10,8
303,
000
2,15
0
1,19
04,
310
390
6,10
039
05,
110
390
950
390
6,21
520
075
1,30
060
01,
800
600
2,15
0
1,00
05,
500
12,3
8095
01,
650
250
2,76
090
2,14
090
1,44
090
9090
4,00
090
1,00
090
1,12
090
2,11
090
1,00
025
01,
000
90390
90 5,320 90210
250
180
310
27-18 customcavity sliding door
Recessed alucobondwall cladding
Recessed alucobondwall cladding - to beflush w/ door frame
2/150steps
2/150 steps
feature timber screen
1200mm high rendered brickworkwall, recessed from main wall face
line of firstfloor over
Recessed T&Gceiling lining tooutdoor living areas
400mm high plinth
Double sidedu/b cupd's
160mm step
lap plinth
2000mm high wall
Remco below ground pool cover housing toLAP POOL / KIDS POOL & separate coverover SPA, installed to manufacturers specs.
27-14 customcavity sliding door
Feature stoneworkto LIFT SHAFT
Concealed cistern
Wall hung vanitywith concealedmirror cabinet above
plumbing duct
plumbing duct
duct27-12 custom
cavity sliding door
Selected clothesline to be mounted min. 100mmbelow top of fence
1100mm high feature wallwith in-built letterbox & lasercut s'less steel street no's
2/ 185 steps2/ 185 steps
160mm step
160mm step
Remco below ground pool cover housing toLAP POOL / KIDS POOL & separate coverover SPA, installed to manufacturers specs.
1190 x 390 Core-filledRendered block pier
1890 x 390 Core-filledRendered block pier
1990 x 390 Core-filledRendered block pier
1190 x 390 Core-filledRendered block pier
200SHS Steel postto eng. detailsExtent of basement below
Extent of basement below
Extent of basement below
2/150steps
2/150 steps
390 x 390 Core-filledRendered block pier
2400mm high openings w/full height timber screennotched around b/head
Water-proofed garden bed overwine store to Builders details
190thick blockwork battenedout 100mm to line-up w/ step
A/C duct
FW
openunder
appl.R
EF
.
Pan
try
COLDROOM
AV /COMMS
LIN
EN
ROBE
LIFT
BUTLERSPANTRY
DRIVEWAY
DINING
FAMILY
LOUNGE PATIO
OUTDOORLIVING
ALFRESCO
BBQ
1200
mm
hig
hba
r to
p
OFFICE
FW
BAR
VOID
overVOID over
BRIDGEover
FOYERENTRYGATEHOUSE
pondpond spill
edge
garden
garden
garden
garden
seat
MEDIA
300mm raisedconc. platform
fireplace
wall mount TV above
SPA
LAPPOOL
2.7m x 10.0m,to pool builders
specs.
1200mm highbar top
gate
1200
mm
hig
h po
ol fe
nce
gate
1200
mm
hig
h po
ol fe
nce
1200
mm
hig
h po
ol fe
nceflat 1:8 fall
gate
bench
BR
OO
M
ST WO
gate
gate
27-4
5 cu
stom
sta
cker
(X
OX
)
plumbingduct
gate
gate
step step
step
KIDS POOL300-450mm deep
shallow pool
SUN DECK
SERVICECOURTYARD
fence mountedclothesline
garden
gate
MW CM
KITCHEN
31-45 (m.o.s) frameless FG5 panel stacking door system, to
manufacturers specs.
31-4
5 (m
.o.s
) fr
amel
ess
FG
5 pa
nel s
tack
ing
door
sys
tem
, to
man
ufac
ture
rs s
pecs
.
gate
gate
REFUSE BINSTORE
SLAB RL - 3.770m A.H.DRL - 3.670m
RL - 3.510m
RL - 3.200m
RL - 3.300m
RL - 3.200m
RL - 3.200m tap
tap
tap
tap
GF
-W01
GF
-W02
GF-W03
GF
-W04
GF
-W05
GF-W06 GF-W07
GF
-W08
GF
-W09
GF
-W10
GF-W11
GF-W12GF-W13
GF
-W14
GF
-W15
GF
-W16
GF
-W17
GF
-W18
GF
-W19
ove
r
2x
GF
-W20
VO
ID over
void
NOTE: SEE SHEETS 22 & 23 FORWINDOW/DOOR SCHEDULE DETAILS
NOTE: ALL DOWNPIPES / GUTTERS & BOXGUTTERS TO BE AS PER HYDRAULICS
ENGINEER DESIGN & DETAILS
POOL SIDE CONC.DECK3.0m x 15.54m (1m C' Levered) with Astro Turf
to landscape builders specs.
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
FLOOR AREAS
BASEMENT:
GROUND FLOOR LIVING AREA:OUTDOOR LIVING AREAS:ENTRY:GATEHOUSE:
FIRST FLOOR LIVING AREA:BED 2 DECK:BED 3 DECK:BED 4 DECK:
SECOND FLOOR LIVING AREA:MASTER DECK:
TOTAL:
456.07 sq.m
319.96 sq.m93.94 sq.m6.00 sq.m9.00 sq.m
329.96 sq.m23.60 sq.m11.00 sq.m11.00 sq.m
164.03 sq.m23.60 sq.m
1448.16 sq.m155.88 sqs
GROUND FLOOR PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
11 23
H120912I021012J151112K200314L260314
60-0
8afg
30-1
6afg
57-1
2afg
60-10afg
1000
ham
per
920
1000
ham
per
820
1000
ham
per
1000
ham
per
1000
ham
per
920
920
820
920
1000hamper920
1000
ham
per
920
1000
ham
per
1000hamper
20-2
7afg
24-0
9alw
24-3
3sta
cker
24-0
9alw
24-0
9alw
24-0
9alw
24-3
6sta
cker
24-2
1SD21
-27a
lw
06-30aaw06-15aaw
06-30aaw06-15aaw
20-27afg
06-30aaw
12-0
9alw
12-09alw12-09alw06-15aaw
24-0
9alw
24-0
9alw
24-1
8afg
06-30aaw
12-18alw
9 10 11 12 13 14 15 16 17 18
D.P
D.P
D.P D.P
D.P D.P
D.P D.P D.P
1 2 3 4 5 6
D.P
D.P
B18
B18
A18
A18
C19
C19
D19
D19
E20
E20
F20
F20
G21
G21
H21
H21
J18
J18
K18
K18
1,150 2,140150
5,800 65090
1,50090
1,80090
1,800 90500
1,00090410 90 5,030
150810 1,190 790 2,015 200 95
2501,460 1,980 5,100 3,370
906,820
1501,190 2,310
1,710250
1,200160
190 1,800190
1,100 90410
90 4,780 90170
90 6,860 150 1,600 1,190 2,310
1505,400
904,590
902,000
905,510
1501,610 390
1505,400
902,000
901,640 600
901,500
902,385 2,000
901,795
1503,500
390 1,610250
4,460 1,980 5,100 1,730 90510 90
2,00090
5,770150
3,205 200 95
5,50
039
06,
100
390
5,11
039
0
150
4,30
090
2,41
024
05,
040
905,
410
150
150
2,02
090
1,00
090
1,10
090
1,00
090
1,32
090
1,00
090
1,62
090
2,39
090
1,60
090
1,00
090 20
0
902,
340
150
250
2,60
019
04,
330
250
4,62
015
0
1,00
0150
4,20
090
600
1,19
01,
660
1,15
01,
150
190
1,84
019
04,
620
150
150
2,76
090
2,95
090
5,19
060
090
1,50
090
1,00
090
1,03
025
02,
300
2,000 4,150 5,420 4,750 7,900 2,000 1,500
3,290 6,100 5,810 7,420 1,600 3,500
1,00
01,
300
1,00
01,
000
27,720
150 5,800 150 5,810 150 2,000 90 5,030 150 2,000 3,100
390 1,610 4,210 90410
90 3,710 90 1,100 90 2,000 90 2,240 90 2,000 90 5,770 150 3,500
12,3
805,
500
1,30
0
19,1
80
5,50
06,
880
5,50
0
1,19
04,
310
9520
095
6,19
520
095
150
4,30
090
2,41
090
5,19
015
05,
500
150
3,11
090
1,10
090
5,21
090
2,39
090
1,60
090
1,00
090
2,63
015
0
1,00
01,
000
4,79
02,
650
390
4,33
05,
020
1,00
015
04,
200
9060
05,
150
1,13
090
2,10
090
1,03
025
02,
300
1,00
015
02,
110
909,
480
901,
000
902,
620
250
1,00
0
Recessed alucobondwall cladding
Recessed alucobondceiling lining to ENTRY roof
Recessed T&Gceiling lining to all decks
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
Stramit colorbond fascias,gutters & downpipes 3 degree Stramit colorbond
trimdeck roof sheeting
3 degree Stramit colorbondtrimdeck roof sheeting
Stramit colorbond fascias,gutters & downpipes
3 degree Stramit colorbondtrimdeck roof sheeting
Feature stoneworkto LIFT SHAFT
strip drain
Concealed cistern
Wall hung vanitywith concealedmirror cabinet above
Concealed cistern
strip drain
Wall hung vanitywith concealedmirror cabinet above
Wall hung vanitywith concealedmirror cabinet above
strip drainFG panel FG panel
Concealed cistern
FG panel
FG panel
duct
A/C duct
A/C duct
A/C duct
1190 x 390 Core-filledRendered block pier
1190 x 390 Core-filledRendered block pier
1190 x 390 Core-filledRendered block pier
1000mm high FG handrail
200SHS Steel poststo eng. details
200SHS Steel post on390 wide x 1100 highrendered plinth to eng. details
Stramit colorbond capping to topof all parapet walls, 1:100 fall back
into roof area, refer Parapet Details
plumbing duct
STORAGE
STORAGE
LIN
EN
VOID
VOID
LIFT
GUESTSUITE
BED 2
BED 3
BED 4
BED 5
W.I.R
W.I.R
W.I.R
W.I.R
W.I.R
FW FW
1000
mm
hig
h F
G h
andr
ail
1000
mm
hig
h F
G h
andr
ail
VOIDover
gatehouseroof
roof
fall
roof fall
roof
fall
1000
mm
hig
h F
G h
andr
ail
1000
mm
hig
h F
G h
andr
ail
DECK
DECK
DECK
1000mm high FG handrail
RL - 7.290mRL - 7.190m
BOX GUTTER
BO
X G
UT
TE
RG
F-W
02
GF
-W20
FF
-W01
GF-W03 FF-W02
FF
-W03
FF-W04
FF-W06
FF-W05
FF-W07
FF
-W08
FF
-W09
FF
-W10
FF
-W11
FF
-W12
FF
-W13
FF
-W14
FF-W15FF-W16
FF-W17FF-W18FF-W19
FF
-W20
FF-W21
FF
-W22
FF
-W23
FF
-W24
FF
-W25
CS
D
CS
D
NOTE: SEE SHEETS 22 & 23 FORWINDOW/DOOR SCHEDULE DETAILS
NOTE: ALL DOWNPIPES / GUTTERS & BOXGUTTERS TO BE AS PER HYDRAULICS
ENGINEER DESIGN & DETAILS
Free standingbath
Free standing
bath
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
FLOOR AREAS
BASEMENT:
GROUND FLOOR LIVING AREA:OUTDOOR LIVING AREAS:ENTRY:GATEHOUSE:
FIRST FLOOR LIVING AREA:BED 2 DECK:BED 3 DECK:BED 4 DECK:
SECOND FLOOR LIVING AREA:MASTER DECK:
TOTAL:
456.07 sq.m
319.96 sq.m93.94 sq.m6.00 sq.m9.00 sq.m
329.96 sq.m23.60 sq.m11.00 sq.m11.00 sq.m
164.03 sq.m23.60 sq.m
1448.16 sq.m155.88 sqs
FIRST FLOOR PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
12 23
H120912I021012J151112K200314L260314
1200
ham
per
920
920
12-1
2afg
12-1
0afg
24-5
4sta
cker
18-2
7alw
06-30aaw
06-30aaw12-09alw
06-15aaw
12-18afg 12-27afg 12-27afg
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
beer
DW
PR
OV
win
e
D.P D.P
D.P
18-2
7alw
D.P
D.P
D.P06-30aaw
06-2
4aaw
B18
B18
A18
A18
C19
C19
D19
D19
E20
E20
F20
F20
G21
G21
H21
H21
J18
J18
K18
K18
06-2
4afg
250
150
1,20
01,
150
190
1,84
019
0
150
2,39
090
410 90
1,40
015
01,
980
3,94
040
02,
390
903,
880
150
390
6,10
039
0
150
3,22
015
06,
580
150
3,37
0
150
4,67
03,
980
1,30
027
02,
050
501,
00015
0
1,230150
600 6,000150
1,600 3,205 200 95
1501,560
2701,500
3505,650
2503,500
2,180 2,480150
4,30090
2,000200
2,410 2,050150
2,790 2,015 200 95
1901,800 190
41090 4,940
901,400
906,660
1505,100
250150 6,740 1,590
908,500
2501,190 2,310
4,660 4,600 6,750 2,790 2,310
7,840 1,230 6,900 1,600 3,500
21,110
290 7,590 150 1,06090 590 90
1,500 350 5,650 250
14,2
20
3,37
04,
190
2,50
02,
220
1,94
0
3,37
015
04,
100
902,
390
9090
903,
700
150
3,37
06,
490
390
3,37
060
0
9520
095
6,19
520
095
150
9,95
090
9090
3,10
015
060
0
150
3,28
090
3,60
090
410
902,
390
270
1,90
020
0 1,00
0150
600
drawers under
Recessed FG windows
2400mm high stonework wall
Stramit colorbond capping to topof all parapet walls, 1:100 fall back
into roof area, refer Parapet Details
Stramit colorbond fascias,gutters & downpipes
3 degree Stramit colorbondtrimdeck roof sheeting
3 degree Stramit colorbondtrimdeck roof sheeting
Stramit colorbond fascias,gutters & downpipes
24-30 customcavity sliding doors(1x2100mm panel,1x1100mm panel)
24-15 customcavity sliding door
Concealed cistern
Wall hung vanitywith concealed
mirror cabinet above
strip drain
A/C duct
A/C duct
3 degree Stramit colorbondtrimdeck roof sheeting
3 degree Stramit colorbondtrimdeck roof sheeting
200SHS Steel post on390 wide x 1100 highrendered plinth to eng. details
200SHS Steel poststo eng. details
1 degree Stramit colorbondklip-lok roof sheeting
2200mm high stonework wallbetween wc & shwr
2400mm high stonework wall
FW
luggagebench
1000
hig
h bu
ilt-in
bed
head
LIFT W.I.R
MASTERSUITE
RETREAT
DECK3 degree raked
ceiling
1000
mm
hig
h F
G h
andr
ail
roof
fall
roof
fall
roof
fall
roof
fall
roof
fall
roof
fall
entry / foyer roof
W.I.
R
1000mm high FG handrail
RL - 10.510mRL - 10.410m
SF
-W01
SF
-W02
SF-W03 SF-W04 SF-W05
SF
-W06
SF
-W07
SF-W08
SF
-W09
SF
-W10
SF
-W11
SF-W12SF-W13
SF-W14
SF-W15
NOTE: SEE SHEETS 22 & 23 FORWINDOW/DOOR SCHEDULE DETAILS
NOTE: ALL DOWNPIPES / GUTTERS & BOXGUTTERS TO BE AS PER HYDRAULICS
ENGINEER DESIGN & DETAILS
BOX GUTTER
Fre
e st
andi
ng
bath
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
FLOOR AREAS
BASEMENT:
GROUND FLOOR LIVING AREA:OUTDOOR LIVING AREAS:ENTRY:GATEHOUSE:
FIRST FLOOR LIVING AREA:BED 2 DECK:BED 3 DECK:BED 4 DECK:
SECOND FLOOR LIVING AREA:MASTER DECK:
TOTAL:
456.07 sq.m
319.96 sq.m93.94 sq.m6.00 sq.m9.00 sq.m
329.96 sq.m23.60 sq.m11.00 sq.m11.00 sq.m
164.03 sq.m23.60 sq.m
1448.16 sq.m155.88 sqs
SECOND FLOOR PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
13 23
H120912I021012J151112K200314L260314
D.P
D.P
D.P
B18
B18
A18
A18
C19
C19
D19
D19
E20
E20
F20
F20
G21
G21
H21
H21
J18
J18
K18
K18
3 degree Stramit colorbondtrimdeck roof sheeting
Stramit colorbond fascias,gutters & downpipes
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
2.5 degree Stramit colorbondtrimdeck roof sheeting
3 degree Stramit colorbondtrimdeck roof sheeting
liftover run
roof
fall
roof fall
roof fall
roof fall
BO
X G
UT
TE
R
BO
X G
UT
TE
RB
OX
GU
TT
ER
NOTE: ALL DOWNPIPES / GUTTERS & BOXGUTTERS TO BE AS PER HYDRAULICS
ENGINEER DESIGN & DETAILS
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
ROOF PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
14 23
H120912I021012J151112K200314L260314
2,40
0
420
3,02
0
500
2,72
0
500
2,72
0
10,9
90
590
10,7
50
490
940
450
490
490
600
250
1,16
0
Rendered foam hood3 degree Stramit colorbond
trimdeck roof sheetingStramit colorbond fascias,gutters & downpipes
3 degree Stramit colorbondtrimdeck roof sheeting
Alum. batten screen
Alum. batten screen
1000mm high FGhandrail, as per BCA 3.9.2
1200mm high FGpool fence, as per AS1926.1
Rendered blockworkto BASEMENT level
Feature stoneworkto LIFT SHAFT
Render 60mm NRGgreenboard cladding
Recessed FG windows
Alucobond wall &ceiling claddingAlucobond wall &ceiling claddingAlucobond wall &ceiling cladding
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
200 SHS steel posts
1000mm high FGhandrail, as per BCA 3.9.2
Rendered brickwork
(BRILLIANTMETALLIC 602)(BRILLIANTMETALLIC 602)
(HNTIO ALASKO TRED) (COLORBOND SURFMIST) (DULUX MOUNT BULLER)
(COLORBOND WOODLAND GREY)
(DULUX LEXICON HALF)
(DULUX MOUNT BULLER)
(DULUX BUNYIP RIVER)
(DULUX LEXICON HALF)
(DULUX LEXICON HALF)
(DULUX BUNYIP RIVER)
(DULUX MOUNT BULLER)
NGL
BUILDING REFENCE LINE -RL 3.230m A.H.D
(COLORBOND WOODLAND GREY)
1200mm high rendered brickworkwall, recessed from main wall face
200SHS Steel post on390 wide x 1100 highrendered plinth to eng. details
3 degree Stramit colorbondtrimdeck roof sheeting
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
Conc. Deck 1m C'Leveredwith Astro Turf
FL FL
FL FL
CL CL
CL CL
FL FL
FL FL
CL CL
CL CL
RL 3.770m
RL 7.290m
RL 10.510m
RL 14.220mRL 14.210mRL 13.980m
fg fg
fg fg fg
fg
fg
fg
fg
fg
fg
fg
RL 0.950m
RL 3.200m
ELEVATION 1 1:100
3,02
0
500
2,72
0
500
2,72
0
10,7
50
640 (inc.40 fascia)
640 (inc.40 fascia) 640 (inc.40 fascia)
640 (inc.40 fascia)
640 (inc.40 fascia)640 (inc.40 fascia)
1,01
7
1,74
0
Rendered foam hood3 degree Stramit colorbondtrimdeck roof sheeting
Stramit colorbond fascias,gutters & downpipes
Alum. batten screen
Feature stoneworkto LIFT SHAFT
Render 60mm NRGgreenboard cladding
1000mm high FGhandrail, as per BCA 3.9.2
1000mm high FGhandrail, as per BCA 3.9.2
1000mm high FGhandrail, as per BCA 3.9.2
Alum. louvre panel doors
1200mm high FGpool fence, as per AS1926.1
Rendered POOL SHELL
200 SHS steel posts
Alum. batten screen
Rendered fence panels
(COLORBOND SURFMIST) (COLORBOND WOODLAND GREY)
(COLORBOND WOODLAND GREY)
(COLORBOND WOODLAND GREY)
(DULUX LEXICON HALF)
(DULUX LEXICON HALF)
(DULUX MOUNT BULLER)
(COLORBOND WOODLAND GREY)
(DULUX LEXICON HALF)
(COLORBOND SURFMIST)
(DULUX LEXICON HALF)
(DULUX MOUNT BULLER)
BUILDING REFENCE LINE -RL 3.230m A.H.D
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
RL 10.510m
RL 14.220mRL 13.980m
NOTE: SEE SHEETS 22 & 23 FORWINDOW/DOOR SCHEDULE DETAILS
NOTE: ALL DOWNPIPES / GUTTERS & BOXGUTTERS TO BE AS PER HYDRAULICS
ENGINEER DESIGN & DETAILS
RL 1.300m
RL 3.510m
ngl RL 3.100m
ELEVATION 2 1:100
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
15 23
H120912I021012J151112K200314L260314
2,40
0
420
3,02
0
500
2,72
0
500
2,72
0
10,6
68
750
110
940
490
490 490
450
640 490 490
1,30
4
3 degree Stramit colorbondtrimdeck roof sheeting
Stramit colorbond fascias,gutters & downpipes
3 degree Stramit colorbondtrimdeck roof sheeting
Alum. batten screen
Rendered blockworkto BASEMENT level
Feature stoneworkto LIFT SHAFT
1000mm high FGhandrail, as per BCA 3.9.2
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
Stramit colorbond capping to topof all parapet walls, 1:100 fall backinto roof area, refer Parapet Details
Rendered brickwork
200 SHS steel posts
1000mm high FGhandrail, as per BCA 3.9.2
Alum. batten screen
Rendered foam hood
Rendered brickwork
Rendered blockwork fenceRetained garden bed
Render 60mm NRGgreenboard cladding
Rendered brickwork
(HNTIO ALASKO TRED)
(DULUX BUNYIP RIVER)
(DULUX BUNYIP RIVER)
(DULUX LEXICON HALF)
(DULUX LEXICON HALF)(COLORBOND SURFMIST)
(COLORBOND SURFMIST)
(COLORBOND WOODLAND GREY)
(COLORBOND WOODLAND GREY)
(COLORBOND WOODLAND GREY)
(COLORBOND WOODLAND GREY)
(DULUX MOUNT BULLER)
(DULUX MOUNT BULLER) (DULUX MOUNT BULLER)
BUILDING REFENCE LINE -RL 3.230m A.H.D
3 degree Stramit colorbondtrimdeck roof sheeting
Rendered foam hood
Conc. Deck 1m C'Leveredwith Astro Turf
FL FL
FL FL
CL CL
CL CL
FL FL
FL FL
CL CL
CL CL
RL 3.770m
RL 7.290m
RL 10.510m
RL 13.898m
RL 3.300m
RL 14.210mRL 14.220m
RL 0.950m
ELEVATION 3 1:100
3,15
0
2,40
050
025
0
1,80
0
1,10
01,
300
500
250
350 2,300 350
Feature stoneworkletterbox
Alum. louvre panel gates(HNTIO ALASKO TRED)
(DULUX BUNYIP RIVER) (COLORBOND SURFMIST)
(DULUX MOUNT BULLER)
fg fg
fg fg
fg fgfg
STREET ELEVATION 5 1:100
10,2
39
2,40
042
03,
020
500
2,72
050
02,
720
10,9
90
640640
640
750
640600640
640
640640
320 640
3 degree Stramit colorbondtrimdeck roof sheeting
Stramit colorbond fascias,gutters & downpipesFeature stonework
to LIFT SHAFT
Alucobond wall &ceiling cladding
Rendered foam hood
3 degree Stramit colorbondtrimdeck roof sheeting
Rendered foam hoodRendered brickwork
Render 60mm NRGgreenboard cladding
Alum. louvre panel gates
Alucobond wall &ceiling cladding
(HNTIO ALASKO TRED) (COLORBOND SURFMIST)
(COLORBOND SURFMIST)
(DULUX LEXICON HALF)
(DULUX LEXICON HALF)
(COLORBOND SURFMIST)
(BRILLIANTMETALLIC 602)
(DULUX MOUNT BULLER)
(BRILLIANTMETALLIC 602)
(DULUX MOUNT BULLER)
(COLORBOND SURFMIST)
(DULUX MOUNT BULLER)
BUILDING REFENCE LINE -RL 3.230m A.H.D
FL FL
FL FL
CL CL
CL CL
FL FL
FL FL
CL CL
CL CL
RL 3.770m
RL 7.290m
RL 10.510m
RL 14.220m
RL 13.469m
fg fg
fg fg
fg
fg
fg
fg
fg
fg
fg
fg
fg
fg
fg
fg fg
fg
fg
fg fgfg
fg
fg
fg
fg
fg fg
fg
RL 0.950m
ELEVATION 4 1:100
NOTE: SEE SHEETS 22 & 23 FORWINDOW/DOOR SCHEDULE DETAILS
NOTE: ALL DOWNPIPES / GUTTERS & BOXGUTTERS TO BE AS PER HYDRAULICS
ENGINEER DESIGN & DETAILS
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
16 23
H120912I021012J151112K200314L260314
wc
1,150 2,140 6,100 15,930 3,100 3,300 3,000
190 1,780 1,350190
1,800 190 7,390 300 4,900 300 3,640 300 2,800 300 2,700 300 1,810 190 1,000
190
1,84
019
04,
580
190
1,00
01,
000
190
4,31
01,
290
4,72
03,
000
4,67
0
190
4,23
035
0
190
4,31
019
080
50 6,560
9,680 2,870
2,000 8,250 2,300
6,690 17,990 1,900 4,100
13,050 900 4,040 300 2,700 300 2,510 190
1,00
013
,380
4,50
01,
300
3,70
015
,180
3,70
030
040
02,
880
400
10,0
0020
080
020
0
3,70
015
,180
1,00
013
,380
300
600
1,80
060
020
0 800
200
5,74
030
06,
900
900
4,04
0
490
1,100
50mm stepdown toALL WET AREAS
1200mm deep pit for Lift, asper manufacturers specs.- t.b.c.
Lift door recess, as permanufacturers specs.
Graded concrete driveway,to engineers specs.
300mm wide stripdrain, depth to eng. specs.
Spa shell to engineers / pool builders specs.
ALL slab & footings to engineersdetails & specifications
Selected termite protectionsystem to underside of slab,perimeter & penetrations, inaccordance with AS 3660.1 Allowance for Remco pool cover,
installed to manufacturers specs.Allowance for Remco pool cover,installed to manufacturers specs.
900 x 300 Rendered Conc.pier, as per engineers spec.900 x 300 Rendered Conc.pier, as per engineers spec.
900 x 300 Rendered Conc.pier, as per engineers spec.
Pool shell to engineers / pool builders specs.
Retaining Wall
Cantilever Above
fw
basin
sink
Basement drainage & sumpdetails to hydraulic
engineers specs., gradeslab to drains accordingly
NOTE: LIFT PIT SIZE / DEPTH T.B.C.ONCE LIFT MANUFACTURER /TYPE HAS BEEN SPECIFIED
pool
she
ll
pool
she
ll
190mm blockwork retaining walls
800m
m h
igh
ret.
wal
l
SLAB RL - 0.950m A.H.D
DRIVEWAY
1:8 fall 1:4.7 fall 1:8 fall
190mm blockwork retaining walls
NOTE: BASEMENT & G.F. SLABS NOT TO BEPOURED BEFORE LIFT TYPE / MANUFACTURER
HAS BEEN SPECIFIED & LIFT PIT / SHAFT DETAILSCONFIRMED W/ LIFT MANUFACTURER
BASEMENT SLAB PLAN
SCALE 1:100
NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
17 23
H120912I021012J151112K200314L260314
wc
2,140 6,100 3,870 8,160 3,200 3,950 3,150 3,000
190 1,610 190 2,850 190 2,900 250 3,600 1,610190
1,800190 440
1,800600
90 1,700
1,395
550
1,01
21,
000
1,00
05,
790
2,65
039
01,
490
3,19
04,
670
212
2,60
039
04,
230
1,72
02,
300
350
4,72
04,
670
1,00
01,
458
390 1,610 1,740 6,690 9,790 1,200 4,410 1,890 850 1,050 900 900 1,000
1,00
02,30
0
1,21
03,
200
250
2,20
01,
000
190
1,84
019
02,
470
2,30
0
4,41
025
02,
300
1,01
21,
000
5,50
012
,380
1,30
0
2,70
016
,130
1,00
02,
850
550
2,88
040
010
,000
2,15
0
1,00
04,
300
1,20
039
07,
790
600
1,80
060
02,
150
1,19
04,
310
390
6,10
039
05,
110
390
950
1,65
0
1,10
01,
000
500
2,010 1,190 3,950 3,150
4,200 2,800 300 2,700 300
2,000 1,990 2,035 200 1,075 2,700 300
5,610 390 1,500 4,700
2,350 4,340
160mm step
duct
2/ 185 steps2/ 185 steps
160mm step
160mm step
1190 x 390 Core-filledRendered block pier
1890 x 390 Core-filledRendered block pier
1990 x 390 Core-filledRendered block pier
1190 x 390 Core-filledRendered block pier
Lift Shaft size, as permanufacturers specs.- t.b.c.
Lift door recess, as permanufacturers specs.
50mm stepdown toALL WET AREAS
plumbing duct
A/C ductfw
tub
sinksink sink
sink
shower
basi
n
fw
GATEHOUSE
spill
edge
garden
garden
gardengarden
step step
step
garden
SLAB RL - 3.770m A.H.D
RL - 3.670m
RL - 3.510m
RL - 3.200m
RL - 3.300m
RL - 3.200m
RL - 3.200m
NOTE: LIFT PIT SIZE / DEPTH T.B.C.ONCE LIFT MANUFACTURER /TYPE HAS BEEN SPECIFIED
STAIR VOID
NOTE: BASEMENT & G.F. SLABS NOT TO BEPOURED BEFORE LIFT TYPE / MANUFACTURER
HAS BEEN SPECIFIED & LIFT PIT / SHAFT DETAILSCONFIRMED W/ LIFT MANUFACTURER
plumbingduct
SLAB RL -
4.070m A.H.D
300mm raisedconc. platform
GROUND FLOOR SLAB PLAN
SCALE 1:100
NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
18 23
H120912I021012J151112K200314L260314
2,40
042
03,
020
500
2,72
0
300
2,72
0
640 (inc.40 fascia)
1,290
640 (inc.40 fascia)640 (inc.40 fascia)
Graded concrete driveway,to engineers specs.
Wall hung vanity withconcealed mirror cabinet above
1 degree Stramit colorbondklip-lok roof sheeting
Box Gutter
SECTION 1:100
9-13A
VOIDGUESTSUITE
OFFICEFOYERMEDIA
300mm raisedplatform
BARVESTIBULE
STORAGEDRIVEWAY PDR
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
FL
NOTE: APPROX. CEILING HEIGHT TO BASEMENTSHOWN SIBJECT TO ENGINEER'S SLAB DESIGN(FFL'S SHOWN TO BE MAINTAINED) MIN. HEAD
CLEARANCE TO BE 2,200mmRL 0.950m
3 degree Stramit colorbond custom orb roof sheeting
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
3 degree timber roof trusses@ 600 centres, to trussmanufacturers specs.
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
ALL Cabinetry to cabinetmaker / interiordesigners specs.
Stramit colorbond capping to topof all parapet walls, 1:100 fall back
into roof area, refer Parapet Details
ALL slab & footings toengineers specs.
190mm blockwork wall,constructed, tanked & waterproofed to engineers details
Suspended slab toengineers specs.
50mm stepdown toALL WET AREAS
2,40
042
03,
020
500
2,72
050
02,
720
640 (inc.40 fascia)
600 (inc.40 fascia)640 (inc.40 fascia)
640 (inc.40 fascia)
640 (inc.40 fascia)
SECTION 1:100B
LIFTWELL
VESTIBULE
STORAGEBASEMENTCARPARKING
RO
BE
OFFICEFOYERMEDIA
REFUSE BINSTORE
ST
OR
AG
E
GUESTSUITE
BED 5
LANDING
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
FL FL
CL CL
RL 10.510m
NOTE: LIFT PIT SIZE / DEPTH T.B.C.ONCE LIFT MANUFACTURER /TYPE HAS BEEN SPECIFIED
300mm raisedplatform
1000mm high FG handrail
2/150mm steps tobottom of staircase
9-13
RL 0.950m
1,20
02,
800
3,52
03,
220
3,45
015
0
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
3 degree timber roof trusses@ 600 centres, to truss
manufacturers specs.
3 degree Stramit colorbond custom orb roof sheeting
ALL slab & footings toengineers specs.
190mm blockwork wall,constructed, tanked & waterproofed to engineers details
Suspended slab toengineers specs.
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
1000mm high FG handrail,as per BCA 3.9.2
RecessedFG windows
Lift shaft headroom concrete slab capping,to engineers/ lift manuf. specs.,min.
3600mm u/s slab to second floor slab level
Lifting beam,to engineers details
SECTION 1:100J9-13
300mm raised conc.platform to MEDIA
1100mm high feature wallwith in-built letterbox & laser
cut s'less steel street no's
FG window inspill edge face
Min.1000mm high FG handrail,as per BCA 3.9.2
Gatehouse Beyond
220high x 250deep Featurerecess full width of pond formedin conc. slab, to engineers spec.Approx. water level
Approx. water level
MEDIA
BAR
Approx. water level
SECTION 1:100K9-13
220high x 250deep Featurerecess full width of pond formedin conc. slab, to engineers spec.
Min.1000mm high FG handrail,as per BCA 3.9.2
BAR DRIVEWAY
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
19 23
H120912I021012J151112K200314L260314
2,40
042
03,
020
500
2,72
050
02,
720
640 (inc.40 fascia)640 (inc.40 fascia)
750 Rendered foam hood
Rendered foam hood
BED 2 BED 3W.I.R W.I.R W.I.R
MASTERSUITE
RETREATENS. WC
DINING FAMILY LOUNGEKITCHEN
BASEMENTCARPARKING
SECTION 1:100C
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
FL FL
CL CL
RL 10.510m
9-13
RL 0.950m
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
2.5 degree timber roof trusses@ 600 centres, to truss
manufacturers specs.2.5 degree Stramit colorbond
custom orb roof sheeting
ALL slab & footings toengineers specs.
190mm blockwork wall,constructed, tanked & waterproofed to engineers details
Suspended slab toengineers specs.
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
50mm stepdown toALL WET AREAS
400mm high plinth
2,40
042
03,
020
500
2,72
050
02,
720
640(inc.40 fascia)
640(inc.40 fascia) 640(inc.40 fascia)
640(inc.40 fascia)
1000mm high FG handrail,as per BCA 3.9.2
Alum. batten screen
1200mm high rendered brickworkwall, recessed from main wall face
Alum. batten screen
Recessed T&G ceiling liningto outdoor living areas 2000mm high rendered
brick wall
BASEMENTCARPARKING
PATIOOUTDOORLIVING
ALFRESCO
BED 2BED 4 DECKENS.
MASTERSUITE
SECTION 1:100D
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
FL FL
CL CL
RL 10.510m1000 high built-in
bed head
9-13
NOTE: APPROX. CEILING HEIGHT TO BASEMENTSHOWN SIBJECT TO ENGINEER'S SLAB DESIGN(FFL'S SHOWN TO BE MAINTAINED) MIN. HEAD
CLEARANCE TO BE 2,200mmRL 0.950m
75mm hebel flooringsystem over timber floor
joists, to engineers specs.
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
3 degree timber roof trusses@ 600 centres, to trussmanufacturers specs.
3 degree Stramit colorbond custom orb roof sheeting
ALL slab & footings toengineers specs.
190mm blockwork wall,constructed, tanked & waterproofed to engineers details
Suspended slab toengineers specs.
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
20 23
H120912I021012J151112K200314L260314
2,40
042
03,
020
500
2,72
050
02,
720
1,035 (inc.40 fascia)490 (inc.40 fascia)
490 (inc.40 fascia)
640 (inc.40 fascia)
Alum. batten screen
1000mm high FG handrail,as per BCA 3.9.2
1000mm high FG handrail,as per BCA 3.9.2
1200mm high FGpool fence, as per AS1926.1
Alum. batten screenAlum. batten screen
1000mm high FG handrail,as per BCA 3.9.2
Feature stoneworkto LIFT SHAFT
Water-proofed garden bed overwine store to Builders details
Recessed T&G ceiling liningto outdoor living areas
Boxed in steel ring beamto engineers spec.
Rafter lintel to be concealed inrafter depth, to engineers detail
Grated drain toedge of lap pool
MASTERSUITE
DECK
BED 2 DECK
FAMILY OUTDOORLIVING
LAPPOOLWINE CELLAR VESTIBULE
BASEMENTCARPARKING
SECTION 1:100E
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
FL FL
CL CL
RL 10.510m
2/150mm steps tobottom of staircase
STAIR INFO:18No. Risers @ 179mmTreads @ 300mm
9-13
RL 0.950m
75mm hebel flooringsystem over timber floor
joists, to engineers specs.
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
2.5 degree timber roof trusses@ 600 centres, to trussmanufacturers specs.
2.5 degree Stramit colorbond custom orb roof sheeting
ALL slab & footings toengineers specs.
190mm blockwork wall,constructed, tanked & waterproofed to engineers details
Suspended slab toengineers specs.
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
Box Gutter
Stramit colorbond capping to topof all parapet walls, 1:100 fall back
into roof area, refer Parapet Details
Open-Tread Stairs w/ steel central stringerto be constructed as per stair manufacturersspecifications & in accordance with BCA 3.9
Open-Tread Stairs w/ steel central stringerto be constructed as per stair manufacturersspecifications & in accordance with BCA 3.9
1000 high built-inbed head
Tiled Suspended slabto engineers specs.
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
Timber rafters @ 600c/s linedto u/side, as per engineers spec.
1,800
490
1,035(inc. 40 fascia)
2,40
042
03,
020
500
2,72
050
02,
720
Alum. batten screen
1000mm high FG handrail,as per BCA 3.9.2
1200mm high FGpool fence, as per AS1926.1
Alum. batten screenAlum. batten screen
1000mm high FG handrail,as per BCA 3.9.2
Feature stoneworkto LIFT SHAFT
1 degree Stramit colorbondklip-lok roof sheeting
Recessed T&G ceiling liningto outdoor living areas
Boxed in steel ring beamto engineers spec.
Rafter lintel to be concealed inrafter depth, to engineers detail
Grated drain toedge of lap pool
BARBASEMENT
CARPARKING
LAPPOOL
FAMILY OUTDOORLIVING
ENTRY
LIN
EN
BED 2W.I.R
DECK
DECK
FOYER
MASTERSUITE
W.I.R
SECTION 1:100F
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
FL FL
CL CL
RL 10.510m
9-13
RL 0.950m
75mm hebel flooringsystem over timber floor
joists, to engineers specs.
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
2.5 degree timber roof trusses@ 600 centres, to trussmanufacturers specs.
2.5 degree Stramit colorbond custom orb roof sheeting
ALL slab & footings toengineers specs.
190mm blockwork wall,constructed, tanked & waterproofed to engineers details
Suspended slab toengineers specs.
3 degree Stramit colorbond custom orb roof sheeting
Box Gutter
Stramit colorbond capping to topof all parapet walls, 1:100 fall back
into roof area, refer Parapet Details
1000 high built-inbed head
75mm hebel flooringsystem over timber floor
joists, to engineers specs.
Open-Tread Stairs w/ steel central stringerto be constructed as per stair manufacturersspecifications & in accordance with BCA 3.9
Open-Tread Stairs w/ steel central stringerto be constructed as per stair manufacturersspecifications & in accordance with BCA 3.9
2/150mm steps tobottom of staircase Tiled Suspended slab
to engineers specs.
3 degree Stramit colorbond custom orb roof sheeting
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
Timber rafters @ 600c/s linedto u/side, as per engineers spec.
Concrete Block Retainingengineers specs.
Astro Turf Finish
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be tinted* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be heat pump, solar or gas*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Provide Vacuumaid System, t.b.c on site, installed tomanufactuers specs.
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
21 23
H120912I021012J151112K200314L260314
2,40
042
03,
020
500
2,72
050
02,
720
490
490
1,200 2,000 8,250 2,000 300
2,34
0
2,37
9
300mm widestrip drain
900 x 300 Rendered Conc.pier, as per engineers spec.900 x 300 Rendered Conc.pier, as per engineers spec.
2.5 degree Stramit colorbond custom orb roof sheeting
Suspended slab toengineers specs.
2.5 degree timber roof trusses@ 600 centres, to trussmanufacturers specs.
75mm hebel flooringsystem over timber floor
joists, to engineers specs.
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
75mm hebel flooringsystem over timber floor
joists, to engineers specs.1000mm high FG handrail,as per BCA 3.9.2
1200mm high pool fence,as per AS 1926.1
300mm raisedconc. platform
Rendered Foam HoodRendered Foam Hood
Grated drain toedge of lap pool
BED 4BED 5
W.I.R
DECK
RETREAT
PASSAGE
COLDROOM
DRIVEWAY
DINING ALFRESCOMEDIA
KIDS POOL300-450mm deep
shallow pool
BASEMENTCARPARKING
SECTION 1:100G
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
RL 3.770m
RL 7.290m
FL FL
CL CL
RL 10.510m
flat 1:8 fall 1:4.7 fall 1:8 fall
9-13
RL 0.950m
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
Box Gutter
Stramit colorbond capping to topof all parapet walls, 1:100 fall back
into roof area, refer Parapet Details
Concrete Block Retainingengineers specs.
Astro Turf Finish
2,40
042
03,
020
500
2,72
050
02,
720
1000mm high FG handrail,as per BCA 3.9.2
1200mm high pool fence,as per AS 1926.1
900 x 300 Rendered Conc.pier, as per engineers spec.900 x 300 Rendered Conc.pier, as per engineers spec.
Grated drain toedge of lap pool
SECTION 1:100H
LIFTWELL
FL FL
FL FL
CL CL
CL CL
FL FL
CL CL
FL FL
CL CL
NOTE: LIFT PIT SIZE / DEPTH T.B.C.ONCE LIFT MANUFACTURER /TYPE HAS BEEN SPECIFIED9-13
RL 3.770m
RL 7.290m
RL 10.510m
BASEMENTCARPARKING
LAPPOOLSTORE
LOUNGE
garden
BR
OO
M
gardengarden
PATIO
STORAGE BED 3
DECK
W.I.R
ENSUITE
RL 0.950m
1,20
02,
800
3,52
03,
220
3,45
015
0
Basement drainage &sump details to hydraulicengineers specs., grade
slab to drains accordingly
2.5 degree timber roof trusses@ 600 centres, to truss
manufacturers specs.
2.5 degree Stramit colorbond custom orb roof sheeting
ALL slab & footings toengineers specs.
190mm blockwork wall,constructed, tanked & waterproofed to engineers details
3 degree Stramit colorbond custom orb roof sheeting
Lift shaft headroom concrete slab capping,to engineers/ lift manuf. specs.,min.
3600mm u/s slab to second floor slab level
Lifting beam,to engineers details
NOTE: SECTION TAKENTHRU' ROOF VERGE
Box Gutter
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
3 degree Stramit colorbond custom orb roof sheeting
Box Gutter
Tiled Suspended slab toengineers specs.
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
75mm hebel flooringsystem over timber floorjoists, to engineers specs.
Suspended slab toengineers specs.
Concrete Block Retainingengineers specs.
Astro Turf Finish
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
22 23
H120912I021012J151112K200314L260314
2,70
03,
300
1,580
835 1,035
6,00
0
5,000
900
300
1,40
040
060
0
2,400 3,000
900
600
900
600
1,050
1,63
842
0
3,910
2,20
0
2,000
1,50
0
4,500
2,70
0
9004,5005,400
2,70
0
2,70
0
2,70
0
1,200 900 900 1,800 900
3,600
2,100
2,10
060
0
2,70
0
2,70
0
1,20
060
0
300
5,70
0
1,200
1,870
90deg angle- Butt Joint Glass
300mm Raisedplatform to MEDIA
RL 3.770mslab level
Awning WINDOW GF-W15
Fixed Glass WINDOWSCorner Window w/'Butt-Joint' Glass
fg fg
RL 3.770mslab level
GF-W16 GF-W17 GF-W18 GF-W19 GF-W20
GF-W01 GF-W02 GF-W04GF-W03 GF-W05 GF-W06 GF-W07
RL 3.770mslab level
GF-W08 GF-W09 GF-W10 GF-W11
GF-W14
GF-W12 GF-W13
RL 0.950mslab level
BF-W01 BF-W02 BF-W03
Awning WINDOWS
Fixed Glass WINDOW
Fixed Glass WINDOW Fixed Glass WINDOW
Fixed Glass WINDOW PANELIFT DOOR
Sliding Glass STACKER DOORSSliding Glass CustomSTACKER DOORS
Louvre WINDOWS14 x fg louvre blades
fg
fg
fg
fg
fg fg
fgfg
fgfg
fgfg
fg
fg
fg fg fg
fg fg
fg
1500 PIVOT DOORSWING INTO FOYER
DOUBLE SHUTTER DOORSSwing Outwards to Pool Pump Room
Sliding Glass STACKER DOORSLouvre WINDOWS27 x fg louvre blades
Louvre WINDOWS27 x fg louvre blades
Louvre WINDOW27 x fg louvre blades
Fixed GlassWINDOWS
820 SWING DOORSWING OUTWARDS FROM L'DRY Fixed Glass WINDOWS
fg
fg
fg
fg
fg
NOTE: CORNER WINDOWSTO BE SITE MEASURED
BASEMENT & GF WINDOW SCHEDULE
SCALE 1:50
BASEMENT WINDOWS
Phone (07) 55 203 022
Fax (07) 55 203 033PO Box 2845 Burleigh Heads DC Qld 4220
Address: 2/71 Township Drive, West Burleigh, QLD 4219ABN 73 097 995 616
BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.
Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
THIS
DE
SIG
N IS
TH
E E
XC
LUS
IVE
PR
OP
ER
TY
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
SN
.B A
LL W
RIT
TE
N D
IME
NS
ION
S T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
SIZ
ES
BE
WA
RN
ED
: SU
BS
TIT
UT
ION
OF
AN
Y S
TR
UC
TU
RA
L M
EM
BE
RS
, AN
D O
R A
NY
VA
RIA
TIO
N T
O A
NY
PA
RT
OF
TH
E D
ES
IGN
WIL
L V
OID
AN
YR
ES
PO
NS
IBIL
ITIE
S O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
FO
R T
HE
ST
RU
CT
UR
AL
INT
EG
RIT
Y A
ND
PE
RF
OR
MA
NC
E O
F T
HE
BU
ILD
ING
CLIENT
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
MEMBER OF
CHARTEREDMEMBER OF
MEMBER OF
queensland inc.association of
building designers
MR. B. & MRS. R. LAND
PROPOSED DWELLING
LOT 47EDGECLIFF DRIVESANCTUARY COVE
4639
RH
A 18/05/2012
B040612C060612D200612E290612F300712G020812
SO
CUSTOM
1:100 @ A2
23 23
H120912I021012J151112K200314L260314
Corner window w/ 'Butt-Joint' Glass
520
2,48
0
3,00
0
1,580 1,5001,8003,000900 900 9002,700
2,700
480
2,00
0
300
2,10
0
1,80
060
0
1,20
01,
200
1,80
060
0
900 9003,3003,6002,100
2,40
0
2,40
0
2,40
0
2,40
0
1,20
01,
200
900 1,800 900 2,700 1,030 120 1,235 1,835 120 2,700 2,400
3,600 7,040
900
600
1,80
060
0
600
1,80
0
2,40
0
1,20
01,
200
1,80
060
0
2,400
1,500 1,500 1,5009005,400900 900 900
3,000 2,700
90deg angle- Butt Joint Glass
RL 7.290mslab level
FF-W01
FF-W03
FF-W22 FF-W23 FF-W24 FF-W25
fg
fg
FF-W02
FF-W04
FF-W15
FF-W07
FF-W21
FF-W05 FF-W06
FF-W16
FF-W19
RL 7.290mslab level
RL 7.290mslab level
SF-W07
RL 10.510mslab level
FF-W08
FF-W10
FF-W12
FF-W14
FF-W09 FF-W11 FF-W13 FF-W17
FF-W18
FF-W20
SF-W01 SF-W02 SF-W03 SF-W04
SF-W05
SF-W06
SF-W08
SF-W14
SF-W12 SF-W09
SF-W11
SF-W10 SF-W13 SF-W15
fg
fg
fg
fg fg fg
fg fg
fg
fg
fg fg fg fg
fg
fg
Fixed Glass WINDOWS Fixed Glass WINDOWS
Fixed Glass WINDOWS
Fixed Glass WINDOWS
Fixed Glass WINDOWS Fixed Glass WINDOWS
Louvre WINDOWS21 x fg louvre blades Awning WINDOWS
Louvre WINDOWS12 x fg louvre blades
Awning WINDOWS
Sliding Glass STACKER DOORS Sliding Glass STACKER DOORS
Sliding Glass DOORS
Louvre WINDOWS24 x fg louvre blades
Louvre WINDOWS12 x fg louvre blades
Louvre WINDOWS24 x fg louvre blades
Louvre WINDOWS24 x fg louvre blades
Fixed GlassWINDOWS
Awning WINDOW
Awning WINDOWSLouvre WINDOWS18 x fg louvre blades
Sliding Glass STACKER DOORS Awning WINDOWLouvre WINDOWS12 x fg louvre blades
NOTE: CORNER WINDOWSTO BE SITE MEASUREDRL 10.510m
slab level
FF & SF WINDOW SCHEDULE
SCALE 1:50
SECOND FLOOR WINDOWS
FIRST FLOOR WINDOWS