8
STRUCTURAL STEEL (REFER TO STRUCT. DWGS.), METALS RESILIENT FLOORING/PLASTIC LAMINATE GLASS ROUGH CUT WOOD RIGID INSULATION FIBERGLASS INSULATION CONCRETE MASONRY UNIT CERAMIC TILE PLYWOOD FINISHED WOOD BRICK CONCRETE GRAVEL FILL EARTH ABBREVIATIONS MOUNTING HEIGHTS AT ACCESSIBLE LOCATIONS CLEARANCE DIMENSIONS AT DOORWAYS APPROACH "B" APPROACH "A" APPROACH "A" APPROACH "B" MATERIAL SYMBOLS PLAN SYMBOLS REFLECTED CEILING SYMBOLS SEE REFLECTED CEILING PLAN A-201 FOR LEGEND. APPROACH "A&B" APPROACH SYMBOLS 36" FF 42" DOOR HANDLES 34" TO BOTTOM EDGE OF REFLECTIVE SURFACE HOOKS 48" max. EMERGENCY CALL CHAIN URINAL WATER CLOSET DRINKING FOUNTAIN 36" MAX. HC 36" to top 36" to top SIDE GRAB BARS REAR GRAB BARS 44" 17"-19" 17" max TOILET PAPER DISPENSER MIRROR LAVATORY 17" min 17" min DRINKING FOUNTAIN SECTION LAVATORY SECTION 8" 27" min 6" 9" 29" min 34" max 27" min 36" max 6" 9" 8" PAPER TOWEL DISPENSER 36" ABV COUNTER 48" max 30" 48" WASTE RECEPTACLE 40" max INSUL. 29" 34" max to rim 48" max LIGHT SWITCH FF FF 15" 39"- 41" 18" 42" min. 12" 18" 7"-9" 15" MIN. 39"-41" 15 3 4 " to C L to C L to C L 38"-43" 1 1 2 " 12" 1 1 2 " GRAB BAR SPACING 48" MAX. 13" LAVATORY FAUCET CONTROL 12" 15" 46" TELEPHONE ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE ADJ ADJACENT ADJUST ADJUSTABLE AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ALLOW ALLOWANCE ALT ALTERNATE ALUM, AL ALUMINUM ANCH ANCHORAGE APPROX APPROXIMATE ARCH'L ARCHITECTURAL ASHP ASPHALT AWC ACOUSTICAL WALL COVERING @ AT BC BRICK COURSES BD BOARD BIT BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM BRG BEARING BRK BRICK BOD BOTTOM OF DECK BOT BOTTOM B/ BOTTOM OF BO BOTTOM OF BUR BUILT-UP ROOF CAB CABINET CB, CKBD CHALKBOARD CG CORNER GUARD CH CEILING HEIGHT CIRC CIRCUMFERENCE CJ CONTROL JOINT CLG, CEIL'G CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT CNTR COUNTER CO CASED OPENING CO CLEAN-OUT COL COLUMN CONC CONCRETE CONT CONTINUOUS CPT CARPET CRS COURSE(S) CT CERAMIC TILE CTD COATED CTR CENTER(ED) DBL DOUBLE DET DETAIL DIAG DIAGONAL DTL DETAIL DIA/DIAM DIAMETER DIM DIMENSION DN DOWN DWG DRAWING DF DRINKING FOUNTAIN DS DOWNSPOUT EA EACH EJ EXPANSION JOINT ELEV ELEVATION ELEC ELECTRICAL ENCL ENCLOSURE EP ELECTRICAL PANELBOARD EQ/ = EQUAL EQUIP EQUIPMENT ETR EXISTING TO REMAIN EWC ELECTRICAL WATER COOLER EXIST EXISTING EXP EXPANSION EXT EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FHC FIRE HOUSE CABINET FIN FINISH(ED) FLASH FLASHING FLR FLOOR F/ FACE OF FR FIRE RATED FRC FIRE RESISTANT COATING FRT FIRE RETARDANT FT FEET, FOOT FTG FOOTING FURR FURRED(ING) GA GAGE, GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GL GLASS GLZ GLAZED GRD GRADE GYP. BD. GYPSUM BOARD GYP GYPSUM HB HOSE BIB HDR HEADER HDWD HARDWOOD HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT HT HEIGHT HGT HEIGHT HP HIGH POINT HR HOUR(S) HTG HEATING HVAC HEATING, VENTILATING AND AIR CONDITIONING HWH HOT WATER HEATER ID INSIDE DIAMTER INCL INCLUDE INSUL INSULATION INT INTEIOR JAN JANITOR JT JOINT KD KNOCK DOWN KO KNOCK OUT L LONG LAM LAMINATED LB, # POUNDS LF LINEAR FEET LKR LOCKER(S) LOC LOCATION LP LOW POINT LT LIGHT MAS MASONRY MAT'L MATERIAL MAX MAXIMUM MDO MEDIUM DENSITY OVERLAY MECH MECHANICAL MED MEDIUM MANUF MANUFACTURER MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MO MASONRY OPENING MTD MOUNTED MTL METAL MUL MULLION N/A NOT APPLICABLE NIC NOT IN CONTRACT NO, # NUMBER NOM NOMINAL NTS NOT TO SCALE OA OVERALL OC ON CENTER OCCUP OCCUPANCY OD OUTSIDE DIAMETER OH OVERHEAD OHG OVERHANG OPNG OPENING OPP OPPOSITE OZ OUNCE PA PUBLIC ADDRESS PERF PERFORATED PL PLATE PL LAM PLASTIC LAMINATE PLAS PLASTER PLYWOOD PLYWOOD PM JT PRE-MOLDED JOINT FILLER PRCST PRECAST P POINT PTD PAINTED PTN PARTITION PT PRESSURE TREATED QT QUARRY TILE R RADIUS RAD RADIATION, RADIATOR RB RUBBER BASE RD ROOF DRAIN REC RECESSED RECT RECTANGULAR REF ROOF EXHAUST FAN REG REGISTER RF ROOF FAN REINF REINFORCED(ING) REQD REQUIRED REFL REFLECTED REM REMOVBLE RLG RAILING RO ROUGH OPENING RL RAINWATER LEADER S&L SPEACH AND LANGUAGE S&P SHELF AND POLE SD SOAP DISPENSER SEC SECTION SGI SMALL GROUP INSTRUCTION SGT STRUCTURAL GLAZED TILE SHWR SHOWER SIM SIMILAR SLV SEAMLESS VINYL SND SANITARY NAPKIN DISPENSER SPEC SPECIFICATION SPK SPEAKER SS STAINLESS STEEL STD STANDARD STL STEEL STRUCT STRUCTURAL SUSP SUSPENDED SYS SYSTEM T TREAD T/, TO TOP OF TOP TOP OF PANEL (PLATE) TOS TOP OF STEEL TBD TO BE DETERMINED TCT TECTUM TD TOP OF DECK TEL TELEPHONE TERR TERRAZZO T&G TONGUE AND GROOVE THK THICK(NESS) THRES THRESHOLD TBD TO BE DETERMINED TLT TOILET TME TO MATCH EXISTING TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TYP TYPICAL UON UNLESS OTHERWISE NOTED VB VINYL BASE VERT VERTICAL VIF VERIFY IN FIELD VNR VENEER VT VINYL TILE W/ WITH WD WOOD WGL WIRE GLASS WI WROUGHT IRON WM WIRE MESH W/0 WITHOUT WPT WORKING POINT WSCT WAINSCOT WSTRP WEATHERSTRIP(PING) WWM WELDED WIRE MESH SHEET NUMBER EXTERIOR ELEVATION NUMBER SHEET NUMBER WALL SECTION DOOR FRAME TYPE SHEET NUMBER DETAIL NUMBER EXISTING DOOR DOOR NUMBER ROOM NUMBER NEW DOOR COLUMN GRID LINE REFERENCE POINT DEMOLITION NOTES WALL or PARTITION TYPE SHEET NUMBER SHEET NUMBER BUILDING SECTION INTERIOR ELEVATION NUMBER SHEET NUMBER SECTION NUMBER REVISION MARK CONSTRUCTION NOTES ### ROOM ### X-X XXX 2 3 4 XXX X XXX X XXX X XXX X X # A2 WINDOW NUMBER XXX X X XXX X REVISIONS: SCALE: DATE: CONSULTANTS DOOR AND FRAME REPLACEMENT AT THREE SCHOOLS TOWN OF WEST HARTFORD MARCH 20, 2020 AS NOTED LOCATION PLAN NOT TO SCALE OakPark Architects LLC 312 Park Rd West Hartford CT 06119 www.opaArch.com 860.232.6664 WEST HARTFORD, CT THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED OR USED IN ANY WAY OTHER THAN WHAT WAS ORIGINALLY INTENDED WITHOUT THE ARCHITECT'S CONSENT. DO NOT SCALE THE DRAWING. USE THE DIMENSIONS GIVEN. IF THERE ARE ANY DISCREPANCIES OR QUESTIONS, CONTACT THE ARCHITECT. A-010 GENERAL MOTES & SPECIFICATIONS 0. DIVISION 00: CONTRACTUAL REQUIREMENTS 0.1. THE ARCHITECTURAL CONTRACT DOCUMENTS FOR THIS PROJECT CONSIST OF DRAWINGS A-010, A-100, A-101, A-102, AND THESE OUTLINE SPECIFICATIONS. 0.2. ALL TRADES ARE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS. 0.3. ALL CONTRACTORS TO HAVE ADEQUATE INSURANCE AND SHALL SUBMIT PROOF OF SAME BEFORE STARTING WORK. 0.4. G.C. TO CONFIRM STAGING AREAS WITH OWNER TO MINIMIZE THE DISTURBANCE OF DAILY BUILDING OPERATIONS AND TO PROTECT EXISTING SITE ELEMENTS (PAVEMENT, SIDEWALKS, LANDSCAPING, ETC.) FROM DAMAGE. 1. DIVISION 01: GENERAL REQUIREMENTS 1.1. PROTECT EXISTING CONSTRUCTION AND SURROUNDING WALLS FROM DAMAGE. 1.2. CONTRACTOR SHALL REPAIR ALL DAMAGED OR MARRED SURFACES DURING CONSTRUCTION. 1.3. ALTERNATIVE PRODUCTS SHALL BE ACCEPTABLE ONLY IF APPROVED BY THE OWNER AND IF EQUAL OR BETTER THAN THE SPECIFIED PRODUCT. 1.4. AREA OUTSIDE OF WORK LIMIT AREA IS FULLY OCCUPIED. CONTRACTOR SHALL MAINTAIN MINIMAL SOUND, DUST AND NOISE LEVELS. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION WITH THE OWNER. 1.5. OWNER SHALL REMOVE ALL FURNITURE AND EQUIPMENT PRIOR TO DEMOLITION. GENERAL CONTRACTOR SHALL COORDINATE ALL REMOVALS. 1.6. PRIOR TO COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF PROJECT ITEMS, THE CONTRACTOR SHALL SUBMIT SUBSTITUTE ITEMS TO THE ARCHITECT FOR REVIEW PRIOR TO BID SELECTION. 1.7. PRODUCT SUBMITTALS OF ALL MATERIALS AND PRODUCTS USED FOR CONSTRUCTION OF THE PROJECT TO BE ISSUED FOR REVIEW PRIOR TO PURCHASE. 1.8. CONTRACTOR SHALL REMOVE ALL CEILINGS, WALL MOUNTED ACCESSORIES, ETC. THAT INTERFERE WITH NEW WORK. 1.9. GEN. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION AMONG ALL TRADES, ENSURING PROPER CLEARANCES BETWEEN ALL NEW WORK AND EXISTING WORK. 1.10. ALL ASPECTS OF THE WORK SHALL CONFORM TO THE REQUIREMENTS OF THE APPLICABLE CODES AS NOTED HEREON. 1.11. IF THE CONTRACTOR ENCOUNTERS INCOMPLETE, INACCURATE OR CONTRADICTORY INFORMATION, OR INFORMATION IN CONFLICT WITH APPLICABLE CODES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE ARCHITECT AND REQUEST RESOLUTION BEFORE FURTHER WORK IS COMPLETED ON THAT ITEM. 1.12. WHERE DRAWINGS AND SPECIFICATIONS CONFLICT, THE MORE STRINGENT AND/OR MORE COSTLY REQUIREMENT SHALL APPLY. THE DECISION WHICH IS MORE STRINGENT AND/OR COSTLY MAY BE RENDERED BY THE ARCHITECT. 1.13. CERTAIN PRODUCT SPECIFICATIONS ARE CONTAINED ON THESE DRAWING SHEETS. 1.14. IF PRODUCTS ARE NOT SPECIFIED, BUILDING STANDARDS ARE TO APPLY. IF BUILDING STANDARDS ARE NOT APPLICABLE, INDUSTRY STANDARDS ARE TO APPLY. 1.15. ALL CONTRACTORS SHALL VISIT THE PROJECT SITE AND FAMILIARIZE THEMSELVES WITH ALL BUILDING AND WORKING CONDITIONS BEFORE SUBMITTING A BID. 1.16. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER & SECURITY PROTECTION DURING DEMOLITION AND CONSTRUCTION. 2. DIVISION 02: DEMOLITION 2.1. DEMOLITION AND REMOVAL - THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION NECESSARY TO COMPLETE THE WORK. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL AND PROPER DISPOSAL, INCLUDING ALL COSTS FOR CARTING AND DUMPING, OF ALL MATERIALS DEMOLISHED FROM THE PROJECT. ALL DISPOSED ITEMS TO BE REMOVED FROM SITE. 2.2. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR ALL EXISTING WORK DISTURBED OR OTHERWISE IN NEED OF REPAIRING IN ORDER TO MAKE THE PROJECT A COMPLETE AND FINISHED PROJECT. THIS REPAIR INCLUDES ALL FINISHES NEEDED TO MATCH ADJACENT SURFACES. 2.3. IF A WALL OR SURFACE IS WORKED ON, THAT WALL OR SURFACE SHALL BE REPAIRED WITH A COMPLETE FINISH, TO THE NEAREST CORNER, CHANGE OF PLANE, OR OTHER JUNCTURE. PROVIDE A SMOOTH AND CLEAN TRANSITION FROM THE NEW FINISHED SURFACE TO THE SURROUNDING EXISTING SURFACES, I.E., THE INTENT IS TO ELIMINATE THE APPEARANCE OF A REPAIRED CONDITION. 2.4. ALL ITEMS SHOWN TO BE DEMOLISHED SHALL BE REMOVED FROM SITE & DISCARDED, UNLESS OTHERWISE NOTED. 2.5. IF A WALL OR SURFACE IS BEING WORKED ON, THAT WALL OR SURFACE SHALL BE REPAIRED WITH A COMPLETE FINISH, TO THE NEAREST CORNER, CHANGE OF PLANE OR THE JUNCTURE, WHICH ALLOWS FOR A SMOOTH AND CLEAN TRANSITION FROM THE NEWLY FINISHED SURFACE TO SURROUNDING EXISTING SURFACES. 3. DIVISION 03: CONCRETE - N/A 4. DIVISION 04: MASONRY - N/A 5. DIVISION 05: METALS - N/A 6. DIVISION 06: WOOD - N/A 7. DIVISION 07: MOISTURE, THERMAL PROTECTION 7.1. THERMAL BATT INSULATION: THICKNESS AS NOTED BY R-VALUE. 7.2. JOINT SEALANTS: 7.2.1. PROVIDE JOINT SEALANTS, BACKINGS, AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND WITH JOINT SUBSTRATES UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY JOINT-SEALANT MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCE. 7.2.2. ARCHITECTURAL SEALANTS SHALL HAVE A VOC CONTENT OF 250 G/L OR LESS. 7.2.3. NEW SEALANT COLORS SHALL MATCH ADJACENT EXISTING. 8. DIVISION 08: DOORS AND WINDOWS 8.1. ALL DOORS TO BE NEW. DAMAGED, SPLIT OR GOUGED DOORS SHALL NOT BE REUSED. 8.2. ALUMINUM DOORS: 8.2.1. NEW DOORS: YKK 50D SERIES, NARROW STILE, COLOR TO MATCH CURTAIN WALL FRAMES. 8.2.2. ALL GLAZED DOORS TO HAVE 1" INSULATED GLAZING, MID RAILS, AND HIGH BOTTOM XT RAILS. 8.2.3. SOLID FLUSH DOORS TO HAVE RIGID INSULATION CORES. 8.2.4. ALL DOORS TO HAVE HARDWARE REINFORCING PLATES. 8.3. ALL NEW LOCKING HARDWARE TO BE KEYED TO OWNER STANDARD. 8.4. DOOR HARDWARE: 8.4.1. CLOSER LCN 4110 FINISH 689 8.4.1.1. PLATE BRACKET: 4110-18 8.4.1.2. CYLINDER ASSEMBLY: 4111(6)-3071 8.4.1.3. PLASTIC COVER: 4110-72 8.4.1.4. ARM: 4110-3077EDA 8.4.1.5. BLADE STOP SPACER: 4110-61 8.4.1.6. FINISH: ALUMINUM 8.4.2. HINGES YKK AP STANDARD OFFSET PIVOTS 8.4.3. KICK PLATES IVES STAINLESS STEEL, BEVEL 4 EDGES, 2” LESS THAN DOOR WIDTH 8.4.4. PANIC DEVICE VON-DUPRIN 99 SERIES VERT ROD PUSH BAR EXIT DEVICE WITH LOCKS 8.4.4.1. GROOVED MECHANISM 8.4.4.2. RIM DEVICE 8.4.4.3. NL-OP NIGHT LATCH w/ PULL 8.4.4.4. US32D FINISH 8.4.4.5. RIM LOCK: 3216 8.4.5. OFFSET PULL VON-DUPRIN 392-7 8.4.6. ELECTRIC STRIKE HES 9600 SURFACE MOUNTED CONTINUOUS DUTY 8.4.6.1. 630 FINISH 8.4.7. THRESHOLD PEMKO 2705T 8.4.8. WEATHER STRIPPING PEMKO 290_S 8.4.9. ASTRAGAL PEMKO 18061_NB 8.5. ALUMINUM-FRAMED EXTERIOR CURTAIN WALL: 8.5.1. YKK'S YES 750 OG FRONT SET THERMALLY IMPROVED SYSTEM WITH 2-1/2” x 7-1/2” GLAZED FRAMES. INTERIOR & EXTERIOR FINISH: ANODIZED, WHITE , YW3N. 8.5.2. METAL INSULATING PANELS: 8.5.2.1. TO HAVE PEBBLE TEXTURE BOTH SIDES, INFILLED WITH POLY-ISO FOAM. 8.5.2.2. PROVIDE MAXIMUM R-VALUE. 8.5.2.3. COLOR: TO MATCH CURTAIN WALL FRAME. 8.4.3. EXTERIOR GLAZING: 8.4.1.1. INTERIOR GLASS: CLEAR TEMPERED GLASS, THICKNESS AS SHOWN. 8.4.1.2. EXTERIOR GLASS: TEMPERED , SOLARBAN® 90 BY VITRO. 8.4.1.3. 1" LARGE INSULATED UNITS: 5/16" THICK. FILL VOIDS WITH ARGON. 8.4.1.4. 1" OPERABLE INSULATED UNITS: 1/4" THICK. FILL VOIDS WITH ARGON. 8.4.1.5. GLAZING NOT AGAINST DOOR FRAMES OR WITHIN 24" OF FLOOR MAY BE SAFETY LAMINATED. 8.5. HARDWARE ELECTRIFICATION 8.5.1. PROVIDE LOW VOLTAGE WIRING IN ALL DOOR FRAMES FOR CURRENT OR FUTURE ELECTRIC HARDWARE. COIL 6' WIRE ABOVE CEILING SPACE. 9. DIVISION 09: FINISHES 9.1. ALL FINISH COLORS AND MATERIALS TO BE BUILDING STANDARD OR APPROVED BY OWNER. 9.2. CEILINGS: 9.2.1. REPAIRED TO MATCH EXISTING. 9.2.2. CEILING & SUSPENSION SYSTEM TO BE CAREFULLY REMOVED FOR REUSE. 9.3. INTERIOR WALL PAINT: BY BENJAMIN MOORE, COLOR BY OWNER. 9.3.1. LATEX PAINT: PRO-MAR 200 , ZERO VOC, EG-SHELL. 10. DIVISION 10: SPECIALTIES 10.1. CAREFULLY DISASSEMBLE ALL EXISTING SECURITY DOOR CONTACTS & FRAME WIRING. REINSTALL ALL SECURITY DOOR CONTACTS WITH CONCEALED WIRING. 11. DIVISION 11: EQUIPMENT - NA 12. DIVISION 12: FURNISHINGS 12.1. ALL FURNITURE IN THE WAY OF DEMOLITION OR CONSTRUCTION TO BE MOVED, KNOCKED DOWN, RELOCATED, REASSEMBLED OR RESET BY OWNER. 12.2. GENERAL CONTRACTOR TO COVER AND PROTECT ANY FURNITURE THAT REMAINS, DURING DEMOLITION & CONSTRUCTION. PROJECT GENERAL NOTES AND SPECIFICATIONS 3/20/2020 2:48:55 PM

PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

STRUCTURAL STEEL (REFER TO STRUCT. DWGS.), METALS

RESILIENT FLOORING/PLASTIC LAMINATE

GLASS

ROUGH CUT WOOD

RIGID INSULATION

FIBERGLASS INSULATION

CONCRETE MASONRY UNIT

CERAMIC TILE

PLYWOOD

FINISHED WOOD

BRICK

CONCRETE

GRAVEL FILL

EARTH

ABBREVIATIONS

MOUNTING HEIGHTS AT ACCESSIBLE LOCATIONS

CLEARANCE DIMENSIONS AT DOORWAYS

APPROACH "B"

APPRO

AC

H "A"

APPRO

AC

H "A"

APPROACH "B"

MATERIAL SYMBOLS

PLAN SYMBOLS

REFLECTED CEILING SYMBOLS

SEE REFLECTED CEILING PLAN A-201 FOR

LEGEND.

APPRO

AC

H "A&B

"

APPRO

AC

H

SYMBOLS

36"

FF

42"

DOOR HANDLES

34"

TO B

OTTO

M E

DGE

OFRE

FLEC

TIVE

SURF

ACE

HOOKS

48" m

ax.

EMERGENCYCALL CHAIN

URINALWATER CLOSET

DRINKINGFOUNTAIN

36" M

AX.

HC36

" to

top

36" t

o to

p

SIDE GRAB BARSREAR GRAB BARS

44"

17"-1

9"

17" m

ax

TOILETPAPER

DISPENSER

MIRRORLAVATORY

17" min

17" min

DRINKING FOUNTAINSECTION

LAVATORYSECTION

8"

27" m

in

6"9" 29" m

in

34" m

ax

27" m

in

36" m

ax

6"9"

8"

PAPER TOWELDISPENSER

36" A

BVCO

UNTE

R

48" m

ax

30"48

"

WASTERECEPTACLE

40" m

ax

INSUL.

29"

34" m

ax to

rim

48" m

ax

LIGHTSWITCH

FF

FF

15"

39"-

41"

18"

42" min.12"

18"

7"-9"

15" M

IN.

39"-41"

15 34"

to CL

to CL

to CL38

"-43"

1 12"12"

1 1 2"

GRAB BARSPACING

48" M

AX. 13"

LAVATORYFAUCET CONTROL

12"

15"℄

46"

TELEPHONE

ACOUS ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

ADJ ADJACENT

ADJUST ADJUSTABLE

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

ALLOW ALLOWANCE

ALT ALTERNATE

ALUM, AL ALUMINUM

ANCH ANCHORAGE

APPROX APPROXIMATE

ARCH'L ARCHITECTURAL

ASHP ASPHALT

AWC ACOUSTICAL WALL COVERING

@ AT

BC BRICK COURSES

BD BOARD

BIT BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BM BEAM

BRG BEARING

BRK BRICK

BOD BOTTOM OF DECK

BOT BOTTOM

B/ BOTTOM OF

BO BOTTOM OF

BUR BUILT-UP ROOF

CAB CABINET

CB, CKBD CHALKBOARD

CG CORNER GUARD

CH CEILING HEIGHT

CIRC CIRCUMFERENCE

CJ CONTROL JOINT

CLG, CEIL'G CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CNTR COUNTER

CO CASED OPENING

CO CLEAN-OUT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

CPT CARPET

CRS COURSE(S)

CT CERAMIC TILE

CTD COATED

CTR CENTER(ED)

DBL DOUBLE

DET DETAIL

DIAG DIAGONAL

DTL DETAIL

DIA/DIAM DIAMETER

DIM DIMENSION

DN DOWN

DWG DRAWING

DF DRINKING FOUNTAIN

DS DOWNSPOUT

EA EACH

EJ EXPANSION JOINT

ELEV ELEVATION

ELEC ELECTRICAL

ENCL ENCLOSURE

EP ELECTRICAL PANELBOARD

EQ/ = EQUAL

EQUIP EQUIPMENT

ETR EXISTING TO REMAIN

EWC ELECTRICAL WATER COOLER

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FHC FIRE HOUSE CABINET

FIN FINISH(ED)

FLASH FLASHING

FLR FLOOR

F/ FACE OF

FR FIRE RATED

FRC FIRE RESISTANT COATING

FRT FIRE RETARDANT

FT FEET, FOOT

FTG FOOTING

FURR FURRED(ING)

GA GAGE, GAUGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GL GLASS

GLZ GLAZED

GRD GRADE

GYP. BD. GYPSUM BOARD

GYP GYPSUM

HB HOSE BIB

HDR HEADER

HDWD HARDWOOD

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HIGH POINT

HT HEIGHT

HGT HEIGHT

HP HIGH POINT

HR HOUR(S)

HTG HEATING

HVAC HEATING, VENTILATING AND

AIR CONDITIONING

HWH HOT WATER HEATER

ID INSIDE DIAMTER

INCL INCLUDE

INSUL INSULATION

INT INTEIOR

JAN JANITOR

JT JOINT

KD KNOCK DOWN

KO KNOCK OUT

L LONG

LAM LAMINATED

LB, # POUNDS

LF LINEAR FEET

LKR LOCKER(S)

LOC LOCATION

LP LOW POINT

LT LIGHT

MAS MASONRY

MAT'L MATERIAL

MAX MAXIMUM

MDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL

MED MEDIUM

MANUF MANUFACTURER

MIN MINIMUM

MIR MIRROR

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

MUL MULLION

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO, # NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OA OVERALL

OC ON CENTER

OCCUP OCCUPANCY

OD OUTSIDE DIAMETER

OH OVERHEAD

OHG OVERHANG

OPNG OPENING

OPP OPPOSITE

OZ OUNCE

PA PUBLIC ADDRESS

PERF PERFORATED

PL PLATE

PL LAM PLASTIC LAMINATE

PLAS PLASTER

PLYWOOD PLYWOOD

PM JT PRE-MOLDED JOINT FILLER

PRCST PRECAST

P POINT

PTD PAINTED

PTN PARTITION

PT PRESSURE TREATED

QT QUARRY TILE

R RADIUS

RAD RADIATION, RADIATOR

RB RUBBER BASE

RD ROOF DRAIN

REC RECESSED

RECT RECTANGULAR

REF ROOF EXHAUST FAN

REG REGISTER

RF ROOF FAN

REINF REINFORCED(ING)

REQD REQUIRED

REFL REFLECTED

REM REMOVBLE

RLG RAILING

RO ROUGH OPENING

RL RAINWATER LEADER

S&L SPEACH AND LANGUAGE

S&P SHELF AND POLE

SD SOAP DISPENSER

SEC SECTION

SGI SMALL GROUP INSTRUCTION

SGT STRUCTURAL GLAZED TILE

SHWR SHOWER

SIM SIMILAR

SLV SEAMLESS VINYL

SND SANITARY NAPKIN DISPENSER

SPEC SPECIFICATION

SPK SPEAKER

SS STAINLESS STEEL

STD STANDARD

STL STEEL

STRUCT STRUCTURAL

SUSP SUSPENDED

SYS SYSTEM

T TREAD

T/, TO TOP OF

TOP TOP OF PANEL (PLATE)

TOS TOP OF STEEL

TBD TO BE DETERMINED

TCT TECTUM

TD TOP OF DECK

TEL TELEPHONE

TERR TERRAZZO

T&G TONGUE AND GROOVE

THK THICK(NESS)

THRES THRESHOLD

TBD TO BE DETERMINED

TLT TOILET

TME TO MATCH EXISTING

TPD TOILET PAPER DISPENSER

TPTN TOILET PARTITION

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

VB VINYL BASE

VERT VERTICAL

VIF VERIFY IN FIELD

VNR VENEER

VT VINYL TILE

W/ WITH

WD WOOD

WGL WIRE GLASS

WI WROUGHT IRON

WM WIRE MESH

W/0 WITHOUT

WPT WORKING POINT

WSCT WAINSCOT

WSTRP WEATHERSTRIP(PING)

WWM WELDED WIRE MESH

SHEET NUMBER

EXTERIOR ELEVATION NUMBER

SHEET NUMBER

WALL SECTION

DOOR FRAME TYPE

SHEET NUMBER

DETAIL NUMBER

EXISTING DOOR

DOOR NUMBER

ROOM NUMBER

NEW DOOR

COLUMN GRID LINE

REFERENCE POINT

DEMOLITION NOTES

WALL or PARTITION TYPE

SHEET NUMBER

SHEET NUMBER

BUILDING SECTION

INTERIOR ELEVATION NUMBER

SHEET NUMBER

SECTION NUMBER

REVISION MARK

CONSTRUCTION NOTES

###

ROOM

###

X-X

XXX

2

3

4

XXX

X

XXX

X

XXX

X

XXX

X

X

#

A2

WINDOW NUMBERXXX

X

X

XXX

X

REVISIONS:

SCALE:

DATE:

CONSULTANTS

DOOR AND FRAMEREPLACEMENT ATTHREE SCHOOLS

TOWN OF WESTHARTFORD

MARCH 20, 2020

AS NOTED

LOCATION PLAN

NOT TO SCALE

OakParkArchitects LLC312 Park Rd West Hartford CT 06119www.opaArch.com 860.232.6664

WEST HARTFORD, CT

THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF THEARCHITECT AND MAY NOT BE REPRODUCED OR USED IN ANY WAYOTHER THAN WHAT WAS ORIGINALLY INTENDED WITHOUT THEARCHITECT'S CONSENT.

DO NOT SCALE THE DRAWING. USE THE DIMENSIONS GIVEN. IF THEREARE ANY DISCREPANCIES OR QUESTIONS, CONTACT THE ARCHITECT.

A-010

GENERAL MOTES &SPECIFICATIONS

0. DIVISION 00: CONTRACTUAL REQUIREMENTS

0.1. THE ARCHITECTURAL CONTRACT DOCUMENTS FOR THIS PROJECT

CONSIST OF DRAWINGS A-010, A-100, A-101, A-102, AND THESE

OUTLINE SPECIFICATIONS.

0.2. ALL TRADES ARE RESPONSIBLE FOR OBTAINING ALL PERMITS AND

INSPECTIONS.

0.3. ALL CONTRACTORS TO HAVE ADEQUATE INSURANCE AND SHALL

SUBMIT PROOF OF SAME BEFORE STARTING WORK.

0.4. G.C. TO CONFIRM STAGING AREAS WITH OWNER TO MINIMIZE THE

DISTURBANCE OF DAILY BUILDING OPERATIONS AND TO PROTECT

EXISTING SITE ELEMENTS (PAVEMENT, SIDEWALKS, LANDSCAPING,

ETC.) FROM DAMAGE.

1. DIVISION 01: GENERAL REQUIREMENTS

1.1. PROTECT EXISTING CONSTRUCTION AND SURROUNDING WALLS FROM

DAMAGE.

1.2. CONTRACTOR SHALL REPAIR ALL DAMAGED OR MARRED SURFACES

DURING CONSTRUCTION.

1.3. ALTERNATIVE PRODUCTS SHALL BE ACCEPTABLE ONLY IF APPROVED

BY THE OWNER AND IF EQUAL OR BETTER THAN THE SPECIFIED

PRODUCT.

1.4. AREA OUTSIDE OF WORK LIMIT AREA IS FULLY OCCUPIED.

CONTRACTOR SHALL MAINTAIN MINIMAL SOUND, DUST AND NOISE

LEVELS. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION WITH

THE OWNER.

1.5. OWNER SHALL REMOVE ALL FURNITURE AND EQUIPMENT PRIOR TO

DEMOLITION. GENERAL CONTRACTOR SHALL COORDINATE ALL

REMOVALS.

1.6. PRIOR TO COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF

PROJECT ITEMS, THE CONTRACTOR SHALL SUBMIT SUBSTITUTE ITEMS

TO THE ARCHITECT FOR REVIEW PRIOR TO BID SELECTION.

1.7. PRODUCT SUBMITTALS OF ALL MATERIALS AND PRODUCTS USED FOR

CONSTRUCTION OF THE PROJECT TO BE ISSUED FOR REVIEW PRIOR

TO PURCHASE.

1.8. CONTRACTOR SHALL REMOVE ALL CEILINGS, WALL MOUNTED

ACCESSORIES, ETC. THAT INTERFERE WITH NEW WORK.

1.9. GEN. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION AMONG

ALL TRADES, ENSURING PROPER CLEARANCES BETWEEN ALL NEW

WORK AND EXISTING WORK.

1.10. ALL ASPECTS OF THE WORK SHALL CONFORM TO THE REQUIREMENTS

OF THE APPLICABLE CODES AS NOTED HEREON.

1.11. IF THE CONTRACTOR ENCOUNTERS INCOMPLETE, INACCURATE OR

CONTRADICTORY INFORMATION, OR INFORMATION IN CONFLICT WITH

APPLICABLE CODES, THE CONTRACTOR SHALL IMMEDIATELY

CONTACT THE ARCHITECT AND REQUEST RESOLUTION BEFORE

FURTHER WORK IS COMPLETED ON THAT ITEM.

1.12. WHERE DRAWINGS AND SPECIFICATIONS CONFLICT, THE MORE

STRINGENT AND/OR MORE COSTLY REQUIREMENT SHALL APPLY. THE

DECISION WHICH IS MORE STRINGENT AND/OR COSTLY MAY BE

RENDERED BY THE ARCHITECT.

1.13. CERTAIN PRODUCT SPECIFICATIONS ARE CONTAINED ON THESE

DRAWING SHEETS.

1.14. IF PRODUCTS ARE NOT SPECIFIED, BUILDING STANDARDS ARE TO

APPLY. IF BUILDING STANDARDS ARE NOT APPLICABLE, INDUSTRY

STANDARDS ARE TO APPLY.

1.15. ALL CONTRACTORS SHALL VISIT THE PROJECT SITE AND FAMILIARIZE

THEMSELVES WITH ALL BUILDING AND WORKING CONDITIONS BEFORE

SUBMITTING A BID.

1.16. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER & SECURITY

PROTECTION DURING DEMOLITION AND CONSTRUCTION.

2. DIVISION 02: DEMOLITION

2.1. DEMOLITION AND REMOVAL - THE CONTRACTOR SHALL BE

RESPONSIBLE FOR ALL DEMOLITION NECESSARY TO COMPLETE THE

WORK. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR

REMOVAL AND PROPER DISPOSAL, INCLUDING ALL COSTS FOR

CARTING AND DUMPING, OF ALL MATERIALS DEMOLISHED FROM THE

PROJECT. ALL DISPOSED ITEMS TO BE REMOVED FROM SITE.

2.2. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR ALL EXISTING

WORK DISTURBED OR OTHERWISE IN NEED OF REPAIRING IN ORDER

TO MAKE THE PROJECT A COMPLETE AND FINISHED PROJECT. THIS

REPAIR INCLUDES ALL FINISHES NEEDED TO MATCH ADJACENT

SURFACES.

2.3. IF A WALL OR SURFACE IS WORKED ON, THAT WALL OR SURFACE

SHALL BE REPAIRED WITH A COMPLETE FINISH, TO THE NEAREST

CORNER, CHANGE OF PLANE, OR OTHER JUNCTURE. PROVIDE A

SMOOTH AND CLEAN TRANSITION FROM THE NEW FINISHED SURFACE

TO THE SURROUNDING EXISTING SURFACES, I.E., THE INTENT IS TO

ELIMINATE THE APPEARANCE OF A REPAIRED CONDITION.

2.4. ALL ITEMS SHOWN TO BE DEMOLISHED SHALL BE REMOVED FROM

SITE & DISCARDED, UNLESS OTHERWISE NOTED.

2.5. IF A WALL OR SURFACE IS BEING WORKED ON, THAT WALL OR

SURFACE SHALL BE REPAIRED WITH A COMPLETE FINISH, TO THE

NEAREST CORNER, CHANGE OF PLANE OR THE JUNCTURE, WHICH

ALLOWS FOR A SMOOTH AND CLEAN TRANSITION FROM THE NEWLY

FINISHED SURFACE TO SURROUNDING EXISTING SURFACES.

3. DIVISION 03: CONCRETE - N/A

4. DIVISION 04: MASONRY - N/A

5. DIVISION 05: METALS - N/A

6. DIVISION 06: WOOD - N/A

7. DIVISION 07: MOISTURE, THERMAL PROTECTION

7.1. THERMAL BATT INSULATION: THICKNESS AS NOTED BY R-VALUE.

7.2. JOINT SEALANTS:

7.2.1. PROVIDE JOINT SEALANTS, BACKINGS, AND OTHER RELATED

MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND

WITH JOINT SUBSTRATES UNDER CONDITIONS OF SERVICE AND

APPLICATION, AS DEMONSTRATED BY JOINT-SEALANT

MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCE.

7.2.2. ARCHITECTURAL SEALANTS SHALL HAVE A VOC CONTENT OF

250 G/L OR LESS.

7.2.3. NEW SEALANT COLORS SHALL MATCH ADJACENT EXISTING.

8. DIVISION 08: DOORS AND WINDOWS

8.1. ALL DOORS TO BE NEW. DAMAGED, SPLIT OR GOUGED DOORS SHALL

NOT BE REUSED.

8.2. ALUMINUM DOORS:

8.2.1. NEW DOORS: YKK 50D SERIES, NARROW STILE, COLOR TO

MATCH CURTAIN WALL FRAMES.

8.2.2. ALL GLAZED DOORS TO HAVE 1" INSULATED GLAZING, MID

RAILS, AND HIGH BOTTOM XT RAILS.

8.2.3. SOLID FLUSH DOORS TO HAVE RIGID INSULATION CORES.

8.2.4. ALL DOORS TO HAVE HARDWARE REINFORCING PLATES.

8.3. ALL NEW LOCKING HARDWARE TO BE KEYED TO OWNER STANDARD.

8.4. DOOR HARDWARE:

8.4.1. CLOSER LCN 4110 FINISH 689

8.4.1.1. PLATE BRACKET: 4110-18

8.4.1.2. CYLINDER ASSEMBLY: 4111(6)-3071

8.4.1.3. PLASTIC COVER: 4110-72

8.4.1.4. ARM: 4110-3077EDA

8.4.1.5. BLADE STOP SPACER: 4110-61

8.4.1.6. FINISH: ALUMINUM

8.4.2. HINGES YKK AP STANDARD OFFSET PIVOTS

8.4.3. KICK PLATES IVES STAINLESS STEEL, BEVEL

4 EDGES, 2” LESS THAN

DOOR WIDTH

8.4.4. PANIC DEVICE VON-DUPRIN 99 SERIES VERT ROD PUSH

BAR EXIT DEVICE WITH LOCKS

8.4.4.1. GROOVED MECHANISM

8.4.4.2. RIM DEVICE

8.4.4.3. NL-OP NIGHT LATCH w/ PULL

8.4.4.4. US32D FINISH

8.4.4.5. RIM LOCK: 3216

8.4.5. OFFSET PULL VON-DUPRIN 392-7

8.4.6. ELECTRIC STRIKE HES 9600 SURFACE MOUNTED

CONTINUOUS DUTY

8.4.6.1. 630 FINISH

8.4.7. THRESHOLD PEMKO 2705T

8.4.8. WEATHER STRIPPING PEMKO 290_S

8.4.9. ASTRAGAL PEMKO 18061_NB

8.5. ALUMINUM-FRAMED EXTERIOR CURTAIN WALL:

8.5.1. YKK'S YES 750 OG FRONT SET THERMALLY IMPROVED SYSTEM

WITH 2-1/2” x 7-1/2” GLAZED FRAMES. INTERIOR & EXTERIOR

FINISH: ANODIZED, WHITE , YW3N.

8.5.2. METAL INSULATING PANELS:

8.5.2.1. TO HAVE PEBBLE TEXTURE BOTH SIDES, INFILLED WITH

POLY-ISO FOAM.

8.5.2.2. PROVIDE MAXIMUM R-VALUE.

8.5.2.3. COLOR: TO MATCH CURTAIN WALL FRAME.

8.4.3. EXTERIOR GLAZING:

8.4.1.1. INTERIOR GLASS: CLEAR TEMPERED GLASS, THICKNESS

AS SHOWN.

8.4.1.2. EXTERIOR GLASS: TEMPERED , SOLARBAN® 90 BY VITRO.

8.4.1.3. 1" LARGE INSULATED UNITS: 5/16" THICK. FILL VOIDS WITH

ARGON.

8.4.1.4. 1" OPERABLE INSULATED UNITS: 1/4" THICK. FILL VOIDS

WITH ARGON.

8.4.1.5. GLAZING NOT AGAINST DOOR FRAMES OR WITHIN 24" OF

FLOOR MAY BE SAFETY LAMINATED.

8.5. HARDWARE ELECTRIFICATION

8.5.1. PROVIDE LOW VOLTAGE WIRING IN ALL DOOR FRAMES FOR

CURRENT OR FUTURE ELECTRIC HARDWARE. COIL 6' WIRE

ABOVE CEILING SPACE.

9. DIVISION 09: FINISHES

9.1. ALL FINISH COLORS AND MATERIALS TO BE BUILDING STANDARD OR

APPROVED BY OWNER.

9.2. CEILINGS:

9.2.1. REPAIRED TO MATCH EXISTING.

9.2.2. CEILING & SUSPENSION SYSTEM TO BE CAREFULLY REMOVED

FOR REUSE.

9.3. INTERIOR WALL PAINT: BY BENJAMIN MOORE, COLOR BY OWNER.

9.3.1. LATEX PAINT: PRO-MAR 200 , ZERO VOC, EG-SHELL.

10. DIVISION 10: SPECIALTIES

10.1. CAREFULLY DISASSEMBLE ALL EXISTING SECURITY DOOR CONTACTS

& FRAME WIRING. REINSTALL ALL SECURITY DOOR CONTACTS WITH

CONCEALED WIRING.

11. DIVISION 11: EQUIPMENT - NA

12. DIVISION 12: FURNISHINGS

12.1. ALL FURNITURE IN THE WAY OF DEMOLITION OR CONSTRUCTION TO

BE MOVED, KNOCKED DOWN, RELOCATED, REASSEMBLED OR RESET

BY OWNER.

12.2. GENERAL CONTRACTOR TO COVER AND PROTECT ANY FURNITURE

THAT REMAINS, DURING DEMOLITION & CONSTRUCTION.

PROJECT GENERAL NOTES AND SPECIFICATIONS

3/2

0/2

02

0 2

:4

8:5

5 P

M

AutoCAD SHX Text
----------
Page 2: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

DN

UP

STOR.

VESTIBULE

CLASSRM

CLASSRM

15'-8

1 2"± V

.I.F

.

7'-0"

10"

1'-10"

8"

3'-8"

HORIZONTAL

MULLION TO BE

1/2" ABOVE

CEILING

BEYOND.

1" CLEAR

TEMPERED

GLAZING (TYP)

EQUAL EQUAL

INSULATED

MTL PANEL

(TYP)

EQ6'-0"

EQ

INSULATED

MTL PANEL

(TYP)

A-1025A

A-1025B

A-1024A

A-1025A

REINSTALL

SECURITY CAMERA

REINSTALL

SECURITY SENSOR

REINSTALL

CARD READER

1

2

34

5 6

7

WEBSTER HILL ELEMENTARY SCHOOL

STOOP

8'-0

"± V

.I.F

.

RAMP

DN

8'-1" ± V.I.F.

DN

CH 7'-11"±

CORRIDOR

SOFFIT

7'-11" ±

CEILING

HEIGHT

BEYOND

REMOVE EMERG WALL

BATTERY PACK

16'-0

"± V

.I.F

.

STOOP

UP

DN

8'-4" ± VIFCH 12'-0"±

CLASSRM

SOFFIT

12-0" ±

CEILING

HEIGHT

BEYOND

REMOVE EMERG WALL

BATTERY PACK

REMOVE

SECURITY

CAMERA

7'-1

1"± V

.I.F

.

STAIRS

BOILER

ROOM

5'-712"

± V.I.F.

UP

CH 8'-0"±

CH 7'-11"±

DOOR NO. 5 & 6

AT GYM REAR

7'-1

1 2"± V

.I.F

.

TO

L

IN

TE

L

7'-1

1 2"± V

.I.F

.

TO

L

IN

TE

L

GYMNASIUM

STOR.

5'-8" ± V.I.F. 5'-8" ± V.I.F.

15'-8

1 2" ±

VIF

STOOP

8'-1134" ± V.I.F.

DN

UP

CH 11'-8"±

STOR.

CLASSRM

SOFFIT

11'-8" ±

CEILING

HEIGHT

BEYOND

REMOVE

DOOR

SENSORS

REMOVE

SECURITY

CAMERA

RAMP

DN

RA

MP

U

P

DN

CH 7'-11"±

CORRIDOR

SOFFIT

STEP

8'-0

"± V

.I.F

.

7'-0

"

10

"1

'-1

0"

8"

3'-8

"

INSULATED

MTL PANEL

(TYP)

EQ6'-0"

EQ

A-1024A

A-1025B

A-1025C

RELOCATED EMERGENCY

WALL PACK

UP

DN

CH 12'-0"±

CLASSRM

16'-0

"± V

.I.F

.

STEP

7'-0

"

10

"

1'-1

0"

8"

3'-8

"

EQ6'-0"

EQ

SOFFIT

12-0" ± CEILING

HEIGHT

BEYOND

HORIZONTAL

MULLION TO

ALIGN WITH

CEILING BEYOND.

1" CLEAR

TEMPERED

GLAZING (TYP)

INSULATED

MTL PANEL

(TYP)

INSULATED

MTL PANEL

(TYP)

A-1025A

A-1024A

A-1025B

A-1025A

A-1025A sim

RELOCATED

EMERGENCY

WALL

PACK

REINSTALL SECURITY CAMERA

STAIRS

BOILER

ROOM

UP

CH 8'-0"±

CH 7'-11"±

7'-1"

± V

.I.F

.

3'-0" 2'-3"

GYMNASIUM

STOR.

7'-1

1

2

"

± V

.I.F

.

TO

LIN

TE

L

7'-1

1

2

"

± V

.I.F

.

TO

LIN

TE

L

3'-0" 2'-3" 3'-0" 2'-3"

NO EXTERIOR PULLS OR

LOCKS THESE DOOR SETS

NOTE: USE SOLID FACED INSULATED DOORS A-100

WEBSTER HILL SCHOOL

A-100

1DOOR NO. 1 - WEBSTER HILL

SCALE: 1/4"=1'-0"A-100

2DOOR NO. 2 - WEBSTER HILL

SCALE: 1/4"=1'-0"

DOOR & FRAME DEMO FLOOR

PLAN

A-100

3DOOR NO. 3

SCALE: 1/4"=1'-0"A-100

4DOOR NO. 4

SCALE: 1/4"=1'-0"A-100

5DOORS NO. 5 & 6

SCALE: 1/4"=1'-0"

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

REVISIONS:

SCALE:

DATE:

CONSULTANTS

DOOR AND FRAMEREPLACEMENT ATTHREE SCHOOLS

TOWN OF WESTHARTFORD

MARCH 20, 2020

AS NOTED

LOCATION PLAN

NOT TO SCALE

OakParkArchitects LLC312 Park Rd West Hartford CT 06119www.opaArch.com 860.232.6664

WEST HARTFORD, CT

THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF THEARCHITECT AND MAY NOT BE REPRODUCED OR USED IN ANY WAYOTHER THAN WHAT WAS ORIGINALLY INTENDED WITHOUT THEARCHITECT'S CONSENT.

DO NOT SCALE THE DRAWING. USE THE DIMENSIONS GIVEN. IF THEREARE ANY DISCREPANCIES OR QUESTIONS, CONTACT THE ARCHITECT.

3/2

0/2

02

0 2

:4

8:5

9 P

M

AutoCAD SHX Text
----------
Page 3: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

13'-2" ± TOP OF

SLOPED

CEILING

BEYOND

13'-2

"± V

.I.F

.

STOOP

GLASS

GLASS

GLASS

GLASS

SOFFIT

RECEIVING OFFICE9'-0" ± V.I.F.

VESTIBULE

CORRIDOR

SEDGWICK MIDDLE SCHOOL FIRST FLOOR

8

9 10

SEDGWICK MIDDLE SCHOOL LOWER LEVEL

VESTIBULE

7'-8

1 4"

6'-0"

1'-7

7

8

6'-0"

SIDELITE

NIC

SIDELITE

NIC

A-1025C

10

"1

'-1

0"

8"

4'-2

"

REINSTALL

DOOR SENSORS

13

12

11

CONARD HIGH SCHOOL

RECEIVING OFFICE

VESTIBULE

CORRIDOR

13'-2

"± V

.I.F

.

STEP

13'-2" ± TOP OF

SLOPED

CEILING

BEYOND

SOFFIT

EQ6'-0"

EQ

A-1024A

A-1025B

A-1025C

A-1025A sim

10"

1'-10"

8"

3'-8"

7'-0"

LOBBY

VESTIBULE

14'-012" ± V.I.F.

7'-8

1 4"± V

.I.F

.

REMOVE DOOR

SENSORS

STOR.STOR.

STAIR

6'-4" ± V.I.F.

7'-0

"± V

.I.F

.

REMOVE DOOR SENSORS

STOR.STOR.

STAIR

7'-1

34"

3'-0"

2'-11

1

2

REINSTALL

DOOR SENSOR

DN

7'-1

0"± V

.I.F

.

TO

LIN

TE

L

3'-2

3

4

"± 3'-2

3

4

DN

6'-10" ± V.I.F.

7'-1

0"± V

.I.F

.

TO

LIN

TE

L

REMOVE DOOR

SENSORS

UPDN

DN

13'-1

"± V

.I.F

.

STAIR

REMOVE

EXIT LIGHT

REMOVE DOOR

SENSORS

UPDN

DN

13'-1

"± V

.I.F

.

STAIR

3'-0"

2'-11

1

2

A-1024A

A-1025C

A-1025A sim

7'-0"

REINSTALL

EXIT LIGHT

REINSTALL

DOOR SENSORS

A-101

SEDGWICK MIDDLESCHOOL AND

CONARD HIGH SCHOOL

A-101

1DOOR NO. 7 - WEBSTER HILL

SCALE: 1/4"=1'-0"A-101

2DOOR NO. 8 - SEDGWICK

SCALE: 1/4"=1'-0"A-101

3DOOR NO. 9 - SEDGWICK

SCALE: 1/4"=1'-0"A-101

4DOOR NO. 10 - SEDGWICK

SCALE: 1/4"=1'-0"A-101

5DOOR NO. 11 - CONARD

SCALE: 1/4"=1'-0"

REVISIONS:

SCALE:

DATE:

CONSULTANTS

DOOR AND FRAMEREPLACEMENT ATTHREE SCHOOLS

TOWN OF WESTHARTFORD

MARCH 20, 2020

AS NOTED

LOCATION PLAN

NOT TO SCALE

OakParkArchitects LLC312 Park Rd West Hartford CT 06119www.opaArch.com 860.232.6664

WEST HARTFORD, CT

THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF THEARCHITECT AND MAY NOT BE REPRODUCED OR USED IN ANY WAYOTHER THAN WHAT WAS ORIGINALLY INTENDED WITHOUT THEARCHITECT'S CONSENT.

DO NOT SCALE THE DRAWING. USE THE DIMENSIONS GIVEN. IF THEREARE ANY DISCREPANCIES OR QUESTIONS, CONTACT THE ARCHITECT.

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

3/2

0/2

02

0 2

:4

9:0

5 P

M

AutoCAD SHX Text
----------
Page 4: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

END CURTAIN WALL DETAIL

SCALE 3" = 1'-0"

4A

A-102

LINE OF EXISTING

MASONRY OR

WALL

STRUCTURE

7

1

2

"

3

8

"

SEALANT OVER

BACKER ROD 1" INSULATED GLASS UNIT or

1" INSULATED METAL PANEL

TYPICAL CURTAIN WALL DETAIL

SCALE 3" = 1'-0"

5A

A-102

CURTAIN WALL BACK

PIECE (TYPICAL)

7

1

2

"

1" INSULATED GLASS UNIT or

1" INSULATED METAL PANEL

1" INSULATED

METAL PANEL

CURTAIN WALL

SET SHIMS IN FULL

BED OF SEALANT

CAULK OVER

BACKER ROD

CAULK OVER

BACKER ROD

EXISTING SLAB/FLOOR

TYPICAL CURTAIN WALL SILL DETAIL

SCALE 3" = 1'-0"

5B

A-102

TYPICAL DOOR BOTTOM RAIL DETAIL

SCALE 3" = 1'-0"

4B

A-102

1" INSULATED

GLAZING

(TEMPERED)

SET ADA METAL

THRESHOLD IN FULL

SEALANT BED

STANDARD

MANUFACTURERS

HIGH BOTTOM RAIL

ANCHOR AS

REQUIRED

1" INSULATED

GLAZING

CURTAIN WALL

ANCHOR AS

REQUIRED

CAULK OVER

BACKER ROD

CAULK OVER

BACKER ROD

EXISTING HEAD

CONSTRUCTION

TYPICAL CURTAIN WALL HEAD DETAIL

SCALE 3" = 1'-0"

5C

A-102

RIGID INSULATION

ALIGN

SHIMS

SEALANT WITH

BACKER ROD

CEILING SOFFIT

SCALE 1 1/2" = 1'-0"

5D

A-103

CURTAIN WALL TOP PLATE and

2x BLOCKING

LINE OF EXISTING

CEILING/SOFFIT

REPAIR CEILING

SYSTEM & PADS

1" INSULATED METAL

PANEL. SEE ELEVATIONS

FOR LOCATIONS

1" INSULATED GLASS

R-13 BATT INSULATION

ANCHOR AS

REQUIRED

7'-1

11 4"± V

.I.F

.

7'-1

11 4"± V

.I.F

.

EQ6'-0" 6'-0"

EQ EQ6'-0" 6'-0"

EQ

A-1024A

A-1024A

A-1025B

A-1025B

A-1025C

A-1025C

10"

1'-10"

8"

4'-5"

7'-9"

10"

1'-10"

8"

4'-5"

7'-9"

REINSTALL

DOOR SENSORS

12'-6" ± V.I.F. 12'-6" ± V.I.F.

7'-1

11 4"± V

.I.F

.

7'-1

11 4"± V

.I.F

.

REMOVE ELECTRICAL

BOX & CONDUIT

REMOVE DOOR

SENSORS

13

12

11

CONARD HIGH SCHOOL

A-102

SCHEDULES AND DETAILS

REVISIONS:

SCALE:

DATE:

CONSULTANTS

DOOR AND FRAMEREPLACEMENT ATTHREE SCHOOLS

TOWN OF WESTHARTFORD

MARCH 20, 2020

AS NOTED

LOCATION PLAN

NOT TO SCALE

OakParkArchitects LLC312 Park Rd West Hartford CT 06119www.opaArch.com 860.232.6664

WEST HARTFORD, CT

THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF THEARCHITECT AND MAY NOT BE REPRODUCED OR USED IN ANY WAYOTHER THAN WHAT WAS ORIGINALLY INTENDED WITHOUT THEARCHITECT'S CONSENT.

DO NOT SCALE THE DRAWING. USE THE DIMENSIONS GIVEN. IF THEREARE ANY DISCREPANCIES OR QUESTIONS, CONTACT THE ARCHITECT.

A-102

1ADOOR SET NO. 12 - CONARD

SCALE: 1/4"=1'-0"

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

A-102

3ADOOR SET NO. 13 - CONARD

SCALE: 1/4"=1'-0"

DOOR & FRAME DEMO FLOOR

PLAN

DOOR & FRAME

DEMO ELEVATION

NEW DOOR & FRAME ELEVATION

NEW DOOR & FRAME FLOOR PLAN

3/2

0/2

02

0 2

:4

9:0

9 P

M

AutoCAD SHX Text
----------
Page 5: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

EXTERIORABATEMENT

SEDGWICK DOOR 8 ABATEMENT PLANSCALE: 1/4" = 1'- 0"

INTERIORABATEMENT

MAT

STOR.

HEPA1000

T T

MAT

STOR.

DA11

DF

STAIR

NEWFLOORING

STOR.

MATMAT

STOR.

DF

DF

DRDR

STAIR

EXTERIORABATEMENT

SEDGWICK DOOR 9 ABATEMENT PLANSCALE: 1/4" = 1'- 0"

INTERIORABATEMENT

MAT

R

HEPA1000

T

T

2DA1

DF

NEWFLOORING

MAT

LINTEL

DFDRDR

SYMBOL KEY - NEW FLOORING

LINTEL PAINTED WITH LEAD-BASED PAINT. PREPARE LINTEL FOR REPAINTING BY REMOVING CAULK, RUST, AND LOOSE PAINT. DISPOSE OF REMOVED PAINT, CAULK, AND RUST AS COMBINATION HAZARDOUS LEAD WASTE WITH LEAD TCLP READING >5 MG/L & PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY.

LINTEL

REMOVE WINDOW SASH AND DISPOSE OF SASH AS SCRAP METAL.

GENERAL NOTES1. REMOVE FLOORING MASTIC USING MECHANICAL METHODS. ADEQUATELY WET FLOOR DURING MASTIC REMOVAL.

2. USE CONCRETE FLOOR PRIMER SPECIFIED IN SECTION 096510 AS THE LOCKDOWN ENCAPSULANT ON THE ABATED FLOORS.

REMOVE DOOR FRAME AND DISPOSE OF FRAME AS COMBINATION ASBESTOS & PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY. SCRAPE DOOR OPENING FREE OF CAULK AND DISPOSE OF CAULK ALONG WITH FRAME.

REMOVE WINDOW FRAME AND DISPOSE OF FRAME AS COMBINATION ASBESTOS & PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY. SCRAPE WINDOW OPENING FREE OF CAULK AND DISPOSE OF CAULK ALONG WITH FRAME.

DF

WF

WS

CONTAINMENT BOUNDARY

REMOVE VINYL ASBESTOS FLOOR, MASTIC, AND VINYL BASE UNDER FULL CONTAINMENT. DISPOSE OF VINYL ASBESTOS FLOOR TILE, MASTIC, AND VINYL BASE AS ASBESTOS WASTE.

REMOVE FLOOR TILE & MASTIC UNDER RADIATOR. REMOVE RADIATOR COVER AS REQUIRED. REINSTALL COVER.

SYMBOL KEY - EXTERIOR ABATEMENTREMOVE DOOR AND DISPOSE OF DOOR AS SCRAP METAL.

REMOVE FLOOR TILE & MASTIC UNDER METAL DOOR THRESHOLD. REMOVE THRESHOLD AS REQUIRED.

NO INTERIOR FLOORING ABATEMENT SCHEDULED FOR THIS AREA.

REMOVE AND STORE RUBBER FLOOR MAT PRIOR TO ABATEMENT.

COMBINATION PERSONNEL DECONTAMINATION UNIT AND WASTE LOAD-OUT UNIT.

NOMINAL CFM SIZE INDICATEDUSE NEAREST WINDOW TO VENT EXHAUST

HEPA FAN UNIT VENTED OUTDOORS

SYMBOL KEY - INTERIOR ASBESTOS ABATEMENT

R

DR

NIA

T

MAT

HEPA2000

NNF

MAT

109

LOCATION PLAN DA1

REINSTALL RUBBER FLOOR MAT REMOVED DURING ABATEMENT.

NO NEW FLOORING SCHEDULED FOR THIS AREA.

SUPPLY AND INSTALL NEW 16" VINYL COMPOSITION FLOOR TILE AND 4" BLACK VINYL BASE. RELEVEL 100% OF THE EXISTING CONCRETE FLOOR WITH A 1/8" LAYER OF HAND-TROWELED LATEX MODIFIED PORTLAND CEMENT BASED LEVELING COMPOUND.

8

SCALE:AS NOTED

DATE:

DESIGN BY:

REVISION:APRIL 6, 2020

JL

SEDGWICK DOOR 10 ABATEMENT PLANDA13

INTERIORABATEMENT

NIA EXTERIORABATEMENT

SCALE: 1/4" = 1'- 0"

LINTEL

WFWF

DFDF

WS

DR DR

NEWFLOORING

NNF

DOORREPLACEMENT

ABATEMENT

SEDGWICKMIDDLE SCHOOL

SEDGWICK SCHOOLWEBSTER HILL SCHOOLCONARD HIGH SCHOOL

West Hartford, CT

Page 6: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

CONARD DOOR 11 ABATEMENT PLANSCALE: 1/4" = 1'- 0"

DF

EXTERIORABATEMENT

INTERIORABATEMENT

VCTNIA

LOBBY

VESTIBULE

DA21

DF

DR

NEWFLOORING

NNF

VESTIBULE

LOBBY

DF

DF

DF

DR DR DR

NEWFLOORING

INTERIORABATEMENT

NIA

VCT

NNF

CONARD DOOR 12 ABATEMENT PLANSCALE: 1/4" = 1'- 0"

DF

DR

EXTERIORABATEMENT

DA22

WFWS

WFWS

DF

DR

DF

DRDR

DFDF

SYMBOL KEY - NEW FLOORING

REMOVE WINDOW FRAME AND DISPOSE OF FRAME AS PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY. SCRAPE WINDOW OPENING FREE OF CAULK AND DISPOSE OF CAULK ALONG WITH FRAME.

SYMBOL KEY - EXTERIOR ABATEMENT

REMOVE WINDOW SASH AND DISPOSE OF SASH AS SCRAP METAL.

REMOVE DOOR FRAME AND DISPOSE OF FRAME AS PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY. SCRAPE DOOR OPENING FREE OF CAULK AND DISPOSE OF CAULK ALONG WITH FRAME.

REMOVE DOOR PAINTED WITH LEAD-BASED PAINT AND DISPOSE OF DOOR AS SCRAP METAL.

REMOVE DOOR AND DISPOSE OF DOOR AS SCRAP METAL.

NO INTERIOR FLOORING ABATEMENT SCHEDULED FOR THIS AREA.

INTERIOR FLOORING AND MASTIC IS NON-ASBESTOS.

SYMBOL KEY - INTERIOR ASBESTOS ABATEMENT

DR

WS

WF

DF

DR1

NIA

VCT

NNF

13

11

LOCATION PLAN DA2

NO NEW FLOORING SCHEDULED FOR THIS AREA.

12

SCALE:AS NOTED

DATE:

DESIGN BY:

REVISION:APRIL 6, 2020

JL

NIA

VCT

INTERIORABATEMENT

NNF

NEWFLOORING 3

DA2

CONARD HIGH SCHOOL

CONARD DOOR 13 ABATEMENT PLANSCALE: 1/4" = 1'- 0"

EXTERIORABATEMENT

DF

DR1

DF

WFWSDF

DR1

WF

WSDFDF

DR1 DR1

West Hartford, CT

DOORREPLACEMENT

ABATEMENT

SEDGWICK SCHOOLWEBSTER HILL SCHOOLCONARD HIGH SCHOOL

Page 7: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

SCALE: 1/4" = 1'- 0"

WEBSTER DOOR 1 ABATEMENT PLAN

EXTERIORABATEMENT

1DA3

INTERIORABATEMENT

NIA

NEWFLOORING

DF

NNF

WSWS WS

WS

WS WS

DR DR

WS

SCALE: 1/4" = 1'- 0"

WEBSTER DOOR 2 ABATEMENT PLAN

EXTERIORABATEMENTVCT

NIA

DA32

INTERIORABATEMENT

NNF

NEWFLOORING

DF

WS

WS

DR DR

SYMBOL KEY - NEW FLOORING

GENERAL NOTES1. REMOVE FLOORING MASTIC USING MECHANICAL METHODS. ADEQUATELY WET FLOOR DURING MASTIC REMOVAL.

2. USE CONCRETE FLOOR PRIMER SPECIFIED IN SECTION 096510 AS THE LOCKDOWN ENCAPSULANT ON THE ABATED FLOORS.

DF1 REMOVE DOOR FRAME AND DISPOSE OF FRAME AS HAZARDOUS LEAD WASTE WITH LEAD TCLP READING >5 MG/L.

WS

REMOVE DOOR FRAME AND DISPOSE OF FRAME AS SOLID WASTE.

DF

REMOVE WINDOW SYSTEM AND DISPOSE OF SYSTEM AS PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY. SCRAPE WINDOW OPENING FREE OF CAULK AND DISPOSE OF CAULK ALONG WITH WINDOW SYSTEM.

WS1 REMOVE WINDOW SYSTEM AND DISPOSE OF SYSTEM AS COMBINED HAZARDOUS LEAD WASTE WITH TCLP LEAD READING >5 MG/L AND PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY. SCRAPE WINDOW OPENING FREE OF CAULK AND DISPOSE OF CAULK ALONG WITH WINDOW SYSTEM.

REMOVE WOOD DOOR AND DISPOSE OF DOOR AS HAZARDOUS LEAD WASTE WITH TCLP LEAD READING >5 MG/L.

DR1

3

VCT INTERIOR FLOORING AND MASTIC IS NON-ASBESTOS.

REMOVE WOOD DOOR AND DISPOSE OF DOOR AS SOLID WASTE.

SYMBOL KEY - EXTERIOR ABATEMENT

DR

NO INTERIOR FLOORING ABATEMENT SCHEDULED FOR THIS AREA.

NNF

NIA

MAT

MAT

T

2000HEPA

SYMBOL KEY - INTERIOR ASBESTOS ABATEMENTHEPA FAN UNIT VENTED OUTDOORSNOMINAL CFM SIZE INDICATEDUSE NEAREST WINDOW TO VENT EXHAUST

COMBINATION PERSONNEL DECONTAMINATION UNIT AND WASTE LOAD-OUT UNIT.

REMOVE AND STORE RUBBER FLOOR MAT PRIOR TO ABATEMENT.

REMOVE FLOOR TILE & MASTIC UNDER METAL DOOR THRESHOLD. REMOVE THRESHOLD AS REQUIRED.

REMOVE VINYL ASBESTOS FLOOR, MASTIC, AND VINYL BASE UNDER FULL CONTAINMENT. DISPOSE OF VINYL ASBESTOS FLOOR TILE, MASTIC, AND VINYL BASE AS ASBESTOS WASTE.

CONTAINMENT BOUNDARY

1

24

5 6

7

DA3LOCATION PLAN

NO NEW FLOORING SCHEDULED FOR THIS AREA.

REINSTALL RUBBER FLOOR MAT REMOVED DURING ABATEMENT.

JL

APRIL 6, 2020REVISION:

DESIGN BY:

DATE:

AS NOTEDSCALE:

SUPPLY AND INSTALL NEW 16" VINYL COMPOSITION FLOOR TILE AND 4" BLACK VINYL BASE. RELEVEL 100% OF THE EXISTING CONCRETE FLOOR WITH A 1/8" LAYER OF HAND-TROWELED LATEX MODIFIED PORTLAND CEMENT BASED LEVELING COMPOUND.

WEBSTER DOOR 3 ABATEMENT PLAN

T

T

HEPA1000

SCALE: 1/4" = 1'- 0"

EXTERIORABATEMENT

INTERIORABATEMENT

3DA3

DF1

WS1WS1

WS1

WS1 WS1DR1 DR1 WEBSTER HILL

SCHOOL

NEWFLOORING

West Hartford, CT

SEDGWICK SCHOOLWEBSTER HILL SCHOOLCONARD HIGH SCHOOL

DOORREPLACEMENT

ABATEMENT

Page 8: PROJECT GENERAL NOTES AND SPECIFICATIONS · 2020-04-16 · 1.12.where drawings and specifications conflict, the more stringent and/or more costly requirement shall apply. the decision

SCALE: 1/4" = 1'- 0"

WEBSTER DOOR 4 ABATEMENT PLAN

EXTERIORABATEMENT1000

HEPA

T

T

1DA4

INTERIORABATEMENT

NEWFLOORING

LINTEL

DF1DRDR

EXTERIORABATEMENT

WEBSTER DOOR 5 & 6 ABATEMENT PLANSCALE: 1/4" = 1'- 0"

NIA NIA

INTERIORABATEMENT

GYM

DA42

LINTEL

DF1

DRDR

NNFNNF

GYM

NEWFLOORING

LINTEL

DF1DRDR

SYMBOL KEY - NEW FLOORING

LINTEL PAINTED WITH LEAD-BASED PAINT. PREPARE LINTEL FOR REPAINTING BY REMOVING CAULK, RUST, AND LOOSE PAINT. DISPOSE OF REMOVED PAINT, CAULK, AND RUST AS COMBINATION HAZARDOUS LEAD WASTE WITH LEAD TCLP READING >5 MG/L & PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY.

LINTEL

2. USE CONCRETE FLOOR PRIMER SPECIFIED IN SECTION 096510 AS THE LOCKDOWN ENCAPSULANT ON THE ABATED FLOORS.

1. REMOVE FLOORING MASTIC USING MECHANICAL METHODS. ADEQUATELY WET FLOOR DURING MASTIC REMOVAL.

GENERAL NOTES

WS1 REMOVE WINDOW SYSTEM AND DISPOSE OF SYSTEM AS COMBINED HAZARDOUS LEAD WASTE WITH TCLP LEAD READING >5 MG/L AND PRESUMED PCB REMEDIATION WASTE WITH PCB LEVEL >50 PPM AT TSCA FACILITY. SCRAPE WINDOW OPENING FREE OF CAULK AND DISPOSE OF CAULK ALONG WITH WINDOW SYSTEM.

3

DR

SYMBOL KEY - EXTERIOR ABATEMENTREMOVE WOOD DOOR AND DISPOSE OF DOOR AS SOLID WASTE.

REMOVE DOOR FRAME AND DISPOSE OF FRAME AS HAZARDOUS LEAD WASTE WITH LEAD TCLP READING >5 MG/L.

DF1

T

NNF

NIA

MAT

MAT

2000HEPA

SYMBOL KEY - INTERIOR ASBESTOS ABATEMENTHEPA FAN UNIT VENTED OUTDOORSNOMINAL CFM SIZE INDICATEDUSE NEAREST WINDOW TO VENT EXHAUST

COMBINATION PERSONNEL DECONTAMINATION UNIT AND WASTE LOAD-OUT UNIT.

REMOVE AND STORE RUBBER FLOOR MAT PRIOR TO ABATEMENT.NO INTERIOR FLOORING ABATEMENT SCHEDULED FOR THIS AREA.

REMOVE FLOOR TILE & MASTIC UNDER METAL DOOR THRESHOLD. REMOVE THRESHOLD AS REQUIRED.

REMOVE VINYL ASBESTOS FLOOR, MASTIC, AND VINYL BASE UNDER FULL CONTAINMENT. DISPOSE OF VINYL ASBESTOS FLOOR TILE, MASTIC, AND VINYL BASE AS ASBESTOS WASTE.

CONTAINMENT BOUNDARY

1

24

5 6

7

DA4LOCATION PLAN

NO NEW FLOORING SCHEDULED FOR THIS AREA.

REINSTALL RUBBER FLOOR MAT REMOVED DURING ABATEMENT.

JL

APRIL 6, 2020REVISION:

DESIGN BY:

DATE:

AS NOTEDSCALE:

SUPPLY AND INSTALL NEW 16" VINYL COMPOSITION FLOOR TILE AND 4" BLACK VINYL BASE. RELEVEL 100% OF THE EXISTING CONCRETE FLOOR WITH A 1/8" LAYER OF HAND-TROWELED LATEX MODIFIED PORTLAND CEMENT BASED LEVELING COMPOUND.

WEBSTER DOOR 7 ABATEMENT PLAN

1000HEPA

T T

INTERIORABATEMENT

SCALE: 1/4" = 1'- 0"

EXTERIORABATEMENT

3DA4

WS1WS1

WS1 WS1WS1

DF1

DRDR

WEBSTER HILL SCHOOL

NEWFLOORING

West Hartford, CT

SEDGWICK SCHOOLWEBSTER HILL SCHOOLCONARD HIGH SCHOOL

DOORREPLACEMENT

ABATEMENT