Programming Instructions

Entry ControllerEC 602-01

Page 2: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

2

Contents

General remarks 3

Input units 4

Programming/Operator interface 5

Circuit diagram relating tothe programming examples 6

Programming examplewith 1 COM 611-... 7

Programming examplewith 1 ELM 611-... 9

Programmable menu points 11

Programming overview 12

Inputs 14

Code request 14

System 15

• Language 15

• Relay function 16

• Gateway function 18

• Changing the code 20

• Disable time 20

Code 22

• Code input 22

• Relay selection 23

• Gateway selection 24

• Time control 24

Key card 25

• Card input 25

• Relay selection 26

• Gateway selection 26

• Time control 27

• Subsequent read-in 28

Key button 29

• Relay selection 29

• Gateway selection 30

• Time control 30

Time 32

Deletion 34

Information 36

Reset 39

Page 3: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

3

General Remarks

ApplicationThe Entry controller EC 602-... isused as an evaluating unit for amaximum of 8 code lock modulesCOM 611-... and/or max. 8Electronic-Key-reading modules ELM 611-... and/or a

ProgrammingThe EC 602-... / ECE 602-... isprogrammed at the keypad directlyat the EC 602-.... .

CodeThe programming menu of theEC 602-... can be protected againstunauthorized access by means of acode. No default code is entered inthe unit.

Continuous displayDisplay after switching on theEC 602-...:

After appr. 7 secs.

Remark:The system is only operational ifa continuous display is visible.

NoteIf no input is made for longer than10 minutes in a programming menu,the EC 602-... automatically switchesback to the continuous display.

maximum of 8 display modulesDIM 611-.... The EC 602-... com-prises 2 relays (switching outputs),the extension unit ECE 602-... offersa further 6 relays, making available amax. of 8 relays.

It is possible to program codes evenif there are no COM 611-... unitsconnected.

Display

Continuous displaySSS Siedle

EC 602-0

EKC/EK 601-... can only beprogrammed if ELM 611-... units areconnected.

Page 4: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

4

Input Units

Address settingCOM 611-...ELM 611-...DIM 611-...All COM 611-..., ELM 611-... andDIM 611-... units connected to theEC 602-.../ECE 602-... must be givenan address between 1 and 8. Under the lid at the back next to theoutlet for the ribbon cable, is therespective BCD switch for address

setting. COM 611-... and/orELM 611-... and/or DIM 611-... unitscombined in a door station are eachgiven the same address. The defaultaddress 1 is always set as standardat all COM 611-..., ELM 611-... andDIM 611-... units. Addresses 0 and 9and double address allocations (atdifferent door stations) lead to asystem malfunction.

LED displays at the ELM 611-...

Red LED flashing: For 3 seconds if an unauthorized EKC 601-... or EK 601-... is presented.

Green LED flashing, red For 1 second as confirmation when LED alight: reading in EKC 601-... or EK 601-....

Green LED flashing: For 3 seconds as confirmation of -executed switching function.

Green LED alight: Continuously when unit is operational.

Red and green LED For 10 seconds when switching on the flashing alternately: unit.

Red and green LED In the programming mode when reading inboth alight: EKC 601-... / EK 601-....

Red LED flashing, green When all 999 EKC/EK 601-... LED alight: have been read in.

Page 5: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

Button functions

Scroll buttons For scrolling forward and back betweenand in the programming menus, and forselecting functions and digits.

Cursor buttons Used for scrolling to the next function ordigit input.

Programming Used to enter the programming levelbutton and to confirm (save) your inputs.

Cancel button Used to quit the individual programmingmenus and to terminate the programming session.

The scrolling and cursor buttons are fitted with a repeat function. If the buttons are held down, thedigits automatically count upwards or the cursor changes continuouslybetween the individual positions.

5

Programming / Operator InterfaceExplanation of Symbols and Button Functions

Access to the keypad and thedisplayThe lid of the housing can beopened by pulling at the upperedge. The display is located underthe housing lid. The keypad islocated on the inside of the housinglid.

OK

ESC

Page 6: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

6

Circuit Diagram relating to theProgramming Examples

DbDa

bvcv

E2E0E1W5W4W3W2W0W1

cvbv

DaDb

COM 611-.../DIM 611-.../ELM 611-...Siedle Vario

Gerätebedarf TR 602-... EC 602-0

Relais 2

Relais 1

Eingang 1

230

V A

C

230

V A

C

Eingang 2

F

4 5 6

7 8 9

0 C

1 32

Vario

busb

c

L1N

NG/TR 602-...

bc

L1N

E1

E2

Tö ext.

Page 7: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

7

Programming Examplewith 1 COM 611- ...

System with EC 602-... and 1 COM 611-... to actuate e.g. 1door release via relay 1. The doorrelease is to remain switched on

Use the programming button toaccess the main menu.

Use the scroll button to access theCode menu.

Using the programming buttonaccess the programming point„Enter code“.

Use the programming button toaccess the programming level.

Now enter the 1-8 digit codenumber, for example 132.

Use the scroll button to select thenumber „1“ in our example. Eachtime the button is pressed, thenumber is indexed upwards.

Use the cursor button to scroll to thenext position.

Continuous display

Press the programming button

Display

Press the scroll button

Display

Press the programming button

Display

Press the programming button

Display

Press the scroll button several timesuntil you reach the number „1“.

Display

Press the cursor button

Display

SSS Siedle

EC 602-0

SYSTEM

OK = Prog = Next

CODE

OK = Prog = Next

Enter code

OK = Prog = Next

OK = Save = New

Code 01 _

OK = Save = New

Code 01 1

OK = save = New

Code 01 1

OK

OK

OK

for 3 seconds.Switching contact at relay 1:Terminals W0 and W2 (n.o.contacts)

Page 8: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

8

For the remaining positions of thecode number, repeat the last twosteps.

Once you have entered all thenumbers, press the programmingbutton to save your entry.

Use the scroll button to assign code01 to relay 1.

Using the programming button, saveyour entry.

Using the cancel button, return tothe Code menu.

Using the cancel button, quit theprogramming level.

The programming sequence isnow completed.

Display

Press the programming button

Display

Press the scroll button

Display

Press the programming button

Display

Press the cancel button

Display

Press the cancel button

Continuous display

OK = save = New

Code 01 132_

Relay 12

Code 01 _

Relay 12

Code 01 L

Disable with Inp.1

Code 01 NO

CODE

OK = Prog = Next

SSS Siedle

EC 602-0

OK

OK

ESC

ESC

Page 9: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

Key card

OK = Prog = Next

Switching contact of relay 1:Terminals W0 and W2 (n.o.contacts)• Please number through theEKC 601-... and/or EK 601-... youwish to read in starting with no.001.

9

System with EC 602-... and 1 ELM 611-... to actuate for example1 door release via relay 1. The doorrelease is to stay switched on for 3secs.

Use the programming button toaccess the main menu.

Press the scroll button to enter theKey card menu.

Use the programming button toaccess the programming point„Card input“.

Use the programming button toenter the programming level.

Holding the EKC/EK 601-... youwish to read in, approach thereading module EML 611-... . Hold the EKC/EK 601-... with thenumber 001 in front of the ELM 611-... . Once the card has been read in, thegreen LED flashes for one second asa confirmation. Read in further EKC/EK 601-... inascending numerical sequence in thesame way. After reading in the 999th EKC/EK 601-..., the red LED flashes whilethe green LED is continuously alight.

Continuous display

Press the programming button

Display

Press the scroll button twice

Display

Press the programming button

Display

Press the programming button

Display

Programming Examplewith 1 ELM 611- ...

OK

OK

OK

It is not possible to read in anyfurther EKC/EK 601-... .If, for example, you have read in 10EKC/EK 601-.. you will see thefollowing display at the EC 602-...(illustrated on page 10):

Card input

OK = Prog ESC = Cancel

OK = Save = New

Card 001 NEW

SYSTEM

OK = Prog = Next

SSS Siedle

EC 602-0

Page 10: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

10

Using the programming button,confirm read-in of the EKC/EK 601-... .

Using the scroll button, assign thecard 001 to relay 1.

Use the programming button tostore your input.

Using the programming button,index to the next number.

For additional EKC/EK 601-... ,repeat the previously describedsteps.Once all the EKC/EK 601-... havebeen programmed, switch back tothe Key Card menu using the cancelbutton.

Use the cancel button to quit theprogramming level.

The programming sequence isnow completed.

Display

Press the programming button

Display

Press the scroll button

Display

Press the programming button

Display

Press the programming button

Display

Press the cancel button

Display

Press the cancel button

Continuous display

OK = Save = New

Card 011 NEW

Relay 12

Card001 _

Relay 12

Card001 L

Disable with input 1

Card 001 NO

Relay 12

Card002 _

Key card

OK = Prog = Next

SSS Siedle

EC 602-0

OK

OK

OK

ESC

ESC

Page 11: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

11

Programmable Menu Points

Programmable Programming DefaultMenu points possibilities setting

SystemLanguage German, English GermanRelay function L (local), G (global) LGateway funct. 4 gateways A,B,C,D – –Changing the code 1-8-digit code – –Disable time 1-59 minutes – –

CodeCode input max. 99 1-8-digit codes – –Relay selection Assignment of codes to COM 611-... – –Gateway selection* A, B, C, D – –Time control No/Yes No

Key cardCard input max. 999 EKC/EK 601-... – –Relay selection Assignment of EKC/EK 601-... – –

to the ELM 611-...Gateway selection* A, B, C, D – –Time control No/Yes No

Key buttonInternal(Release button at the COM/DIM 611-...)Relay selection Assign release buttons of

COM 611-..., DIM 611-... – –Gateway selection* A, B, C, D – –Time control No/Yes NoExternal (external release buttons)Relay selection Assignment of external release buttons – –Gateway selection* A, B, C, D – –Time control No/Yes No

TimeRelease time (relays) 1 sec. - 59 min 59 sec. EC 602-..: 3 sec / ECE 602-..: 3 secPause time (gateways)* 1 sec. - 59 min 59 sec. – –

DeletionDelete code word** OK (Yes), ESC (No) – –Delete code** OK (Yes), ESC (No) – –Delete card** OK (Yes), ESC (No) – –Delete gateway** OK (Yes), ESC (No) – –

InformationDisplay code OK (Yes), ESC (quit) – –Display card OK (Yes), ESC (quit)

Points marked with* only appear ifthe relevant conditions have beenprogrammed in the System menu.

Points marked with **only appear if the relevant functionshave been programmed.

Page 12: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

Enter code

with and

and confirm with .

12

ProgrammingOverview

Code input necessary?

CODE REQUESTCode..._

Language

Relay function

Gateway function

Changing thecode

Disable time

Code input

Relay selectionRelay 12

Gateway selection*Gateway AB

Time controlDisable with ...

Card input

Relay selectionRelay 12

Gateway selection*Gateway AB

Time controlDisable with ...

SSS SiedleEC 602-0

OK

ESC

ESC

ESC

ESC

ESC

or

OK

OK

or

OK

or

OK

or

ESC

OK

or

OK

or

OK

or

OK

or

OK

or

OK

or

right

wrong

No

yes

SYSTEM

ESC ESC

KEY CARD(only accessed if ELM 611- ...

is connected)

CODE

ESC

ESC

ESC

ESC

ESC

ESC

ESC

ESC

OK OK OK

Page 13: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

13

Relay selectionRelay 12

Gateway selection*Gateway AB

Time controlDisable with...

Relay

Gateway*

Delete code**

Delete code**

Delete card**

Delete Gateway**

Display code

Display card

OK

or

OK

or

OK

or

OK

or

OK

or

OK

or

OK

or

ESC ESC ESC ESC

INFORMATIONDELETETIMEKEY BUTTON

ESC

ESC

ESC

ESC

ESC

ESC

ESC

ESC

ESC

ESC

ESC

OK OK OK OK

Programming points marked with *only appear if the relevantconditions have been programmedin the System menu.

Programming points marked with **only appear if the relevant functionshave been entered.

Page 14: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

Input 1:Control input for disabling codes,EKC/EK 601-..., internal key buttons(in COM 611-... andDIM 611-...) and external keybuttons (door release buttons).Input 1 can be connected, forexample, via a timer.The disable function can beprogrammed selectively for each ofthe above-mentioned inputpossibilities. Input 1 is also effectivefor the key buttons in case of ageneral release of internal andexternal key buttons via input 2.

CODE REQUEST

Code -

14

InputsCode Request

InputsThe Easikey Controller EC 602-...comprises 2 inputs, E1 and E2, forexternal release or disabling ofswitching functions.

NoteNo external voltage may be appliedat inputs E1 and E2. They areconnected by means of floatingcontacts between E0/E1 / E0/E2.

Code requestThe code request is accessed bypressing the programming button.

If no code has been assigned or thecode has been deleted, the mainSystem menu appears.

Select the 1st digit of the code, ifnecessary by pressing the scrollbutton several times.

In the case of a multi-digit code,scroll to the next position with thecursor button.

Repeat the last two steps as often asnecessary until the code has beencompletely entered. Using the programming button,confirm the code.

If the code has been correctlyentered, the following displayappears.

Input 2:Control input for general release ofkey buttons in COM 611-... andDIM 611-... as well as external keybuttons (door release buttons).The key buttons are only functional ifinput 2 is connected.

Continuous display

Press the programming button

Display if no code has beenprogrammed.

or display if a code word has beenprogrammed.

Continue to press the scroll buttonuntil the 1st digit of the code isdisplayed.

Press the cursor button

Press the programming button

Display

Using the scroll buttons, it is possibleto access the other menus. If thecode is incorrectly entered, thecontinuous display appears again andthe code request must be repeated.

SSS Siedle

EC 602-0

SYSTEM

OK = Prog = Next

SYSTEM

OK = Prog = Next

OK

OK

Page 15: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

15

System:Language

Explanation of termsThe System menu contains thefollowing programming points:• Language• Relay function• Gateway function• Changing the code• Disable time

Programming example

Pressing the programming buttoncauses the programming pointLanguage to appear.

Language

Use the programming button toaccess the language programminglevel.

Use the scroll button to selectGerman or English. For this example,please select German.Using the programming button,confirm that programming is to beperformed in German.

Language programming point:Operator prompting is set asstandard in the German language.For German programmers, theprogramming point „Language“ cantherefore be bypassed if you wishoperator prompting to be German.

Operator prompting can optionallybe set for English.

Display

Press the programming button

Display

The scroll buttons can be used ifrequired for accessing the otherprogramming points individually.

Display

Press the programming button

Display

Press the programming button

Display

button scrolls forward

button scrolls back

OK = save = New

German

SYSTEM

OK = Prog = Next

Language

OK = Prog = Next

Language

OK = Prog = Next

Relay function

OK = Prog = Next

OK

OK

OK

Page 16: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

16

System:Relay function

Relay functionThis programming point determinesthe function of the relays(local/global function).The function defined here isautomatically taken over into the

L LocalL (locally) programmed relays canonly be triggered via assigned COM/ ELM/DIM 611-... :- Relay 1 from COM/ELM/

DIM 611-... with address 1,- Relay 2 from COM/ELM/

DIM 611-... with address 2, etc.

G GlobalG (globally) programmed relays canbe triggered by all COM/ELM/DIM 611-... units, provided validcodes / EKC/ EK 601-... are entered,or the key button function isassigned.

next menu. For this reason, a changeof function also leads to a change inthe next menus when assigningindividual codes, EKC/EK 601-... andkey buttons.

Example: • Relay 2 is locally programmed (L) • In the Code menu, code 0 isassigned to relay 2

Example:• Relay 1 is globally (G) programmed,relay 2 locally (L), • In the Code menu, code 01 isassigned to relay 1, code 02 to relay2, code 03 to relays 1 and 2.

This means that relay 1 can beactuated by all COM/ELM/DIM 611-... units, while relay 2 canonly be actuated by COM/ELM/DIM 611-... with address 2.

When entering ...

... Code 01 at COM 611-... with address 1, relay 1 switches,

... Code 01 at COM 611-... with address 2, relay 1 switches,

... Code 02 at COM 611-... with address 1, no relay switches,

... Code 02 at COM 611-... with address 2, relay 2 switches,

... Code 03 at COM 611-... with address 1, relay 1 switches,

... Code 03 at COM 611-... with address 2, relays 1 and 2 switch.

When entering ...

... Code 01 at COM 611-... with address 2, relay 2 switches.

... Code 01 at COM 611-... with address 1, relay 2 does not switch.

Page 17: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

17

Sole operation of EC 602-... without ECE 602-...:In the case of local (L) programmingof the relays, a maximum of 2

On/Off function:With EC/ECE 602-... it is also poss-ible to implement an on/offfunction. For this, the relevant relaymust be globally (G) programmed,

Programming example

Use the programming button toaccess the programming level for therelay function.

Use the scroll button to change alocal (L) default setting to a global(G) setting if required, for examplerelay 1:

If you wish to change other relaysfrom L to G, change the cursorposition using the cursor buttonand repeat the last step if in eachcase. Using the programming button,confirm the inputs.

input units can be connected(COM/ELM/DIM 611-...). However, if at least one of the relaysis globally programmed (G) up to

the release time must beprogrammed at 00 min.00 sec. inthe Time menu. When actuatedonce by Code input, with an EKC/EK601-... or key button, the

8 input units can be connected.

relevant relay picks up and whenactuated twice it releases again.

Display

Press the programming button

Display without ECE 602-...

Display with ECE 602-...

Press the scroll button

Display without ECE 602-...

Display with ECE 602-...

Press the programming button

Display

button scrolls forward

button scrolls back

Relay function

OK = Prog = Next

Relay 1 2

Output L L

Relay 1 2 3 4 5 6 7 8

Output L L L L L L L L

Relay 1 2

Output G L

Relay 1 2 3 4 5 6 7 8

Output G L L L L L L L

Gateway function

OK = Prog = Next

OK

OK

Page 18: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

18

System:Gateway Function

Gateway function:It is possible to implement amaximum of 2 gateways (A, B) withthe EC 602-... , and 4 gateways (A,B, C, D) with the ECE 602-... .A gateway permits the automaticswitching sequence of 2 relays.

Programming example

Use the programming button toenter the gateway functionprogramming level.

By pressing the scroll button, selectthe 1st relay of the gateway, e.g. 1.

Use the cursor button to scroll to the2nd position.

By pressing the scroll button, selectthe 2nd relay of the gateway, e.g. 2.

Using the programming button,confirm gateway A.

The switching sequence can bedefined at will. The relay placed firstin the switching sequence (Out 1)always switches first. After a freelydefined delay, the relay placedsecond (Out 2) then switches.

Gateways can be initiatedirrespective of local/globalprogramming of the involved relaysfrom different positions.

• The gateway function isprogrammed irrespectively of therelay function.

Display

Press the programming button

Display

Press the scroll button

Display

Press the cursor button

Press the scroll button

Display

Press the programming button

1st pos. 2nd pos. Initiation of the gateway

Local L Global G from COM/ELM/DIM 611-... using the addressor agreeing with the 1st pos. of the sequenceLocal L

Global G Local L from COM/ELM/DIM 611-... using the addressagreeing with the 2nd pos. of the sequence

Global G Global G Optionally from all the COM/ELM/DIM 611-...if valid codes or EKC/EK 601-... are enteredor if the key button function is assigned accordingly

Gateway function

OK = Prog = Next

Funct. Out 1/Out 2

Gateway A _/

Funct. Out 1/Out 2

Gateway A 1/

Funct. Out 1/Out 2

Gateway A 1/2

OK

OK

Page 19: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

19

To define additional gateways,repeat the previous steps.

If all the possibilities for gatewayformation have been utilized, afterconfirming with the programmingbutton, the following displayappears:

If not all possibilities for gatewayformation have been utilized, afterconfirming with the programmingbutton, use the cancel button to quitthe programming point.

In order to access the programmingpoints Code or Disable time, pressthe programming button.

Display

Display

button scrolls forward

button scrolls back

Press the cancel button

Display

Press the programming button

Display

button scrolls forward

button scrolls back

Funct. Out 1/Out 2

Gateway B _/

Changing the code

OK = Prog = Next

SYSTEM

OK = Prog = Next

Language

OK = Prog = Next

OK

ESC

Page 20: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

20

System:Changing the CodeDisable Time

Changing the codeIf required, this programming pointcan be used to define a code with 1- 8 digits.

Use the programming button toaccess the code programming level.

Select the first digit of the code bypressing the scroll button as often asrequired.

In the case of a code with severaldigits, move the cursor position bypressing the cursor button.

Repeat the last two steps as often asrequired until the code has beencompletely entered.

Use the programming button toconfirm the code word or index onto the next programming point.

Disable timeIn this programming point, it ispossible to program an input disablefunction from 1 - 59 minutes. Thisoccurs after 10 failed code inputattempts at the COM 611-..., orafter presenting 10 invalid EKC/EK 601-... to the ELM 611-... . Allfurther input attempts during thedisabled period are ignored.

Use the programming button toenter the disable time programminglevel.

Display

Press the programming button

Display

Continue to press the scroll buttonuntil the 1st digit of the code isdisplayed.

Press the cursor button

Press the programming button

Display

button scrolls forward

button scrolls back

Display

Press the programming button

Display

Disable time

OK = Prog = Next

Changing the code

OK = Prog = Next

OK = Save = New

Code _

Disable time

OK = Prog = Next

OK = Save = New

Disable time 00m

OK

OK

OK

Page 21: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

21

Enter the units for the disable timeby pressing the scroll button ifnecessary several times.

To enter the tens, change the cursorposition using the cursor button.

Repeat the steps for the entering thenumber as for the units.

Use the programming button toconfirm the entered disable time.

Use the cancel button to return tothe System menu point.

Programming can be terminated atany time using the button.

Continue to press the scroll buttonuntil the required units value hasbeen entered for the disable time.

Press the cursor button

Press the programming button

Display

button scrolls forward

button scrolls back

Press the cancel button

Display

button scrolls forward

button scrolls back

Language

OK = Prog = Next

SYSTEM

OK = Prog = Next

OK

ESC

ESC

Page 22: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

22

Code:Code Input

CodeThe Code menu contains thefollowing programming points:• Code input• Relay selection*• Gateway selection*• Time control*

Code inputUsing this programming point, amaximum of 99 F codes are defined.These codes can have 1-8 digits.

Programming exampleYou wish to enter 2345 for the firstcode.

Pressing the programming buttoncauses the programming point„Code input“ to appear.

Use the programming button toenter the programming level.

Now program the code no. This canhave between 1 and 8 digits, e.g.2345.

Using the scroll key, select thenumber „2“ as in our example.Every time the button pressed, thenumber indexes upwards by one.

The programming points markedwith * are included in theprogramming point „Code input“and are automatically accessedthere. However, they can also bemanually accessed outside thisprogramming point using the scrollbuttons. The programming point„Gateway selection“ only appears ifat least one gateway has beendefined in the System menu.

Double assignment of codes is notpossible.If, for example, code 01 has beenprogrammed with code no. 111,and you also wish to assign thenumber 111 to code 09, afterconfirmation using the programmingbutton, code 01 is automaticallydisplayed after confirming with theprogramming button.Codes can be optionally assigned torelays and/or gateways.

Display

Press the programming button

Display

Using the scroll buttons, it is possibleto access the other programmingpoints individually.

Display

Press the programming button

Display

Press the scroll buttons several timesuntil you reach the number „2“.

CODE

OK = Prog = Next

Code input

OK = Prog = Next

Code input

OK = Prog = Next

OK = Save = New

Code 01 _

OK

OK

Page 23: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

OK

23

Code:Card InputRelay Selection

Use the cursor buttons to scroll tothe next position.

For the remaining digits of the codenumber, repeat the last two steps.

Once all the numbers have beenentered, press the programmingbutton to save your entries.

Relay selection

Starting from the display, it ispossible to assign code 01 to relay 1using the scroll button. If you wishto change code 01 or assign it toother relays, move the cursor using.

If you do not wish to assign code 01to any relay, please press the pro-gramming button

In our example, code 01 is assignedto relay 1.

Use the programming button to saveyour entry.

Display

Press the cursor button

Display

Display

Press the programming button

Display without ECE 602-...

Display with ECE 602-...

Press the scroll button

Display without ECE 602-...

Display with ECE 602-...

Press the programming button

DisplayIf no gateway has been programmedin the „Gateway funct.“programming point.

OK = Save = New

Code 01 2

OK = Save = New

Code 01 2_

OK = Save = New

Code 01 2345

Relay 1 2 3 4 5 6 7 8

Code 01 _

Relay 1 2

Code 01 _

Relay 1 2

Code 01 L

Relay 1 2 3 4 5 6 7 8

Code 01 L

Disable with inp. 1

Code 01 NO

OK

OK

the cursor button to the relevantposition and assign the code 01 tothe required relay using the scrollbutton.

Page 24: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

24

Code:Gateway Selection, Time Control

orGateway selection

Starting from the display, it ispossible to assign code 01 togateway A using the scroll button. Ifyou wish to change code 01 orassign it to other gateways, move

If you do not wish to assign code 01to a gateway, press the pro-gramming button .

In our example, code 01 is assignedto gateway A.

Use the programming button to saveyour entry.

Time control

This programming point is used todefine whether code 01 can bedisabled via input 1. Using the scrollbutton , it is possible to selectbetween NO and YES. Save yourselection with the programmingbutton .

Program further codes in the sameway. Once all the codes have beenprogrammed, quit the programminglevel with the cancel button.

Programming can be terminated atany time using the cancel button

.

Display without ECE 602-...

Display with ECE 602-...if a gateway has been programmedin the System menu under theprogramming point „Gatewayfunct.“.

Press the scroll button

Display without ECE 602-...

Display with ECE 602-...

Press the programming button.

Display

Press the programming button

Display

Press the cancel button

Display

button scrolls forward

button scrolls back

Gateway A B

Code 01 _

Gateway A B C

Code 01 _

Gateway A B

Code 01 X

Gateway A B CD

Code 01 X

Disable with inp. 1

Code 01 NO

OK = Save = New

Code 02 _

CODE

OK = Prog = Next

OK

OK

ESC

the cursor to the relevant positionusing the cursor button and assigncode 01 to the required gatewayusing the scroll button.

OK

OK

ESC

Page 25: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

25

Key Card:Card input

Key cardThe Key button menu is onlyaccessed if at least 1 ELM 611-... isconnected. The Key card menucontains the following programmingpoints.:• Card input• Relay selection*• Gateway selection*• Time control*

Card inputIn this programming point, amaximum of 999 EKC/EK 601-... areread in.

Programming example:

Pressing the programming buttoncauses the programming point„Card input“ to appear.

Use the programming button toenter the programming level.

Approach the reading moduleELM 611-... which has the lowestaddress with the EKC/EK 601-... youwish to read in. At this module, bothLEDs should be alight. Hold theEKC/EK 601-... with the number 001in front of the ELM 611-... .

Use the programming button toconfirm input of the EKC/EK 601-...

The programming points markedwith * are included in the program-ming routine for the programmingpoint „Card input“ and areautomatically accessed there. However, they can also be accessedoutside this programming pointmanually using the scroll buttons.

If the system contains 2 or morereading modules ELM 611-..., theEKC/EK 601-... can only be read inat the ELM 611-... with thelowest address.

Once the EKC/EK 601-... has beenread in, the green LED flashes forone second as conformation.Read in other EKC/EK 601-... inrising sequence of numbering usingthe same method. After reading the999th EKC/EK 601-..., the red

The „Gateway selection“programming point only appears ifat least one gateway has beendefined in the System menu. Keycards (EKC/EK 601-...) can beoptionally assigned to relays and/orgateways.

• Please number through theEKC 601-... and/or EK 601-... youwish to read in beginning withno. 001.

Display

Press the programming button

Display

Press the programming button

Display

LED flashes while the green LEDremains alight. No further EKC/EK 601-... can now be read in.If you have read in, e.g., 10 EKC/EK 601-... you will see the followingdisplay at the EC 602-...:

Display

Press the programming button

Key card

OK = Prog = Next

Card input

OK = Prog ESC = Can.

OK = Save = New

Card 001 NEW

OK = Save = New

Card 011 NEW

OK

OK

OK

Page 26: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

26

Key Card:Relay Selection, Gateway Selection

Relay selection

If you do not wish to assign card001 to any relay, press theprogramming button .

Starting from the display, it ispossible to assign card 001 to relayone using the scroll buttons. If youwish to change card 001 or assign itto a different relay, move the cursor.

In our example, relay 1 is assigned.

Use the programming button to saveyour entry.

orGateway selection

If you do not wish to assign card001 to any gateway, please pressthe programming button .

Starting from the display, it ispossible to assign card 001 togateway A using the scroll button.

If you wish to assign card 001 todifferent or additional gateways,move the cursor to the requiredposition and assign card 001 to therequired gateway using the scroll

Display without ECE 602-...

Display with ECE 602-...

Press the scroll button

Display without ECE 602-...

Display with ECE 602-...

Press the programming button

Display... if no gateway has beenprogrammed in the SYSTEM menuunder „Gateway funct.“.

Display without ECE 602-...

Display with ECE 602-...... if a gateway has beenprogrammed in the SYSTEM menuunder „Gateway funct.“..

Relay 1 2

Card 001 _

Relay 1 2 3 4 5 6 7 8

Card 001 _

Relay 1 2

Card 001 L

Relay 1 2 3 4 5 6 7 8

Card 001 L

Disable with inp.1

Card 001 NO

Gateway A B

Card 001 _

Gateway A B C D

Card 001 _

OK

using the cursor button to therelevant position and assign card001 to the required relay using thescroll button.

OK

OK

buttons.In our example, it is assigned togateway A.

Page 27: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

27

Key CardGateway Selection, Time Control

Assigning card 001 to gateway A

Use the programming button to saveyour entry.

Time control

This programming point is used todefine whether card 001 can bedisabled via input 1. Using the scrollbutton , it is possible to selectbetween yes and no. Use theprogramming button to save theentered selection.

For additional cards (EKC/EK 601-...) repeat the previous steps.

When all the EKC/EK 601-... havebeen programmed, switch back intothe Key card menu using the cancelbutton.

Programming can be terminated atany time using the cancel button

.

Press the scroll button

Display without ECE 602-...

Display with ECE 602-...

Press the programming button.

Display

Press the programming button.

Display without ECE 602-...

Display with ECE 602-...

Press the cancel button

Display

button scrolls forward

button scrolls back

Gateway A B

Card 001 X

Gateway A B C D

Card 001 X

Disable with inp. 1

Card 001 NO

Relay 1 2

Card 002 _

Relay 1 2 3 4 5 6 7 8

Card 002 _

Key card

OK = Prog = Next

OK

OK

ESC

ESC

Page 28: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

28

Key Card:Subsequent Input of further EKC/EK 601-...

Subsequent input of furtherEKC/EK 601-...Programming example:

Pressing the programming buttoncauses the programming point„Card input“ to appear.

In the display of the EC 602-... , thefirst free position is automaticallyindicated. This can also be a gapbetween other inputs, for example ifindividual EKC/EK 601-... have beendeleted.

Approach the reading moduleELM 611-... which has the lowestaddress with the EKC/EK 601-... youwish to read in. Both LEDs should bealight at this module.Hold the EKC/EK 601-... in risingnumerical sequence in front of theELM 611-..., whereby already

assigned positions are automaticallybypassed. The free positions areaccessed in rising nu-mericalsequence. For each EKC/EK 601-...,the green LED flashes for 1 secondas a confirmation. After reading inthe 999th EKC/EK 601-..., the redLED flashes, while the green LED

Display

Press the programming button

Display

Using the scroll buttons, it is possibleto access further programmingpoints.

Display

Press the programming button

Display

remains alight. No further EKC/EK 601-... can be read in.

The remaining sequence is the sameas that described on page 25.

Key card

OK = Prog = Next

Card input

OK = Prog = Next

Card input

OK = Prog = Next

OK = Save = New

Card XXX NEW

OK

OK

Page 29: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

29

Key buttonIn the Key button menu, it ispossible to assign entitlement forthe internal key buttons in the COM 611-... / DIM 611-... and forthe external key buttons.

Programming example:

Pressing the programming buttoncauses the programming point“Relay selection“ to appear.

Relay selection

Starting from the display, it ispossible to release the key buttonsat the COM/DIM 611-... which hasthe address 1 using the scrollbutton. If you wish to release thekey buttons at other COM/DIM 611-... units, move the cursorto the relevant position using thecursor button and release the keybuttons using the scroll button.In our example, the key buttons arereleased at the COM/DIM 611-...with address number 1.

The Key button menu contains thefollowing programming points:• Relay selection• Gateway selection*• Time control*The programming points markedwith * are included in the program-ming routine of the programmingpoint „Relay selection“ and are

automatically accessed there.However, they can be manuallyaccessed outside this programmingpoint using the scroll buttons.The programming point „Gatewayselection“ only appears if at leastone gateway has been defined inthe System menu.

Display

Press the programming button

Display

The scroll buttons can be used toaccess the programming pointsindividually.

Display

Press the programming button

Display without ECE 602-...

Display with ECE 602-...

Press the scroll button

Display without ECE 602-...

Display with ECE 602-...

Key button

OK = Prog = Next

Relay selection

OK = Prog = Next

Key ButtonRelay Selection

Relay selection

OK = Prog = Next

Relay 1 2

Internal _

Relay 1 2 3 4 5 6 7 8

Internal _

Relay 1 2

Internal L

Relay 1 2 3 4 5 6 7 8

Internal L

OK

OK

Page 30: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

30

Key ButtonGateway Selection, Time control

Use the programming button to saveyour entry.

Gateway selection

From this display, it is possible torelease the key buttons at theCOM/DIM 611-... which has theaddress 1 for gateway A using thescroll buttons. If you wish to releasethe key buttons for gateways atother COM/ DIM 611-... units, movethe cursor using the cursor button tothe relevant position and assign thekey buttons to the gateway ... usingthe scroll button.In our example, the key buttons arereleased at the COM/DIM 611-...which has the address 1.

Use the programming button to saveyour entry.

Time control

This programming point is used todefine whether the key buttons atCOM/DIM 611-... can be disabledwith input 1. Using the scroll button

it is possible to select betweenYES and NO.

Save your selection with theprogramming button.

Press the programming button

Displayif no gateway has been programmedin the System menu under„Gateway funct.“.

Display without ECE 602-...

Display with ECE 602-...if a gateway has been programmedin the System menu under„Gateway funct.“.

Press the scroll button

Display without ECE 602-...

Display with ECE 602-...

Press the programming button.

Display

Press the programming button.

Disable with Inp. 1

Card 001 NO

Gateway A B C D

Internal _

Gateway A B

Internal _

Gateway A B

Internal X

Gateway A B C D

Internal X

Disable with Inp. 1

Internal

OK

OK

OK

Page 31: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

31

Key Button

The external key buttons are nowreleased as required. This isperformed using the same sequenceas for the internal key buttons. Thedisplays differ only in one point:Instead of the designation„Internal“, the word „External“appears.

To terminate key buttonprogramming, press the cancelbutton.

Programming can be terminated atany time using the Cancel button .

Display without ECE 602-...

or display with ECE 602-...

Press the cancel button

Display

button scrolls forward

button scrolls back

Relay 1 2 3 4 5 6 7 8

External _

Relay 1 2

External _

Key button

OK = Prog = Next

ESC

ESC

Page 32: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

32

Time

TimeIn the Time menu, the switchingtimes for the relays and the delaytimes for the gateways are defined.

The Time menu contains thefollowing programming points:• Relay• Gateway*

* The programming point„Gateway“ only appears if at leastone gateway has been defined inthe System menu.

Programming example:

Pressing the programming buttoncauses the programming point„Relay“ to appear.

Any changes to the switching time,e.g. 3 secs., are performed using thescroll button . The cursorposition is altered using the cursorbutton .

Confirm the entered value using theprogramming button.

A default switching time of 3seconds is set for relay 1 and 2.These can be changed in incrementsof one second up to max. 59minutes and 59 seconds.Remark:The switching time of 00 minutes 00seconds has been entered for theON/OFF function. The pause time forgateways can be set in increments of1 second to max. 59 minutes and 59seconds.

The delay time is the time periodbetween switching start of the 1stand 2nd relays in a gatewayconfiguration. For example:1st relay switches for 3 seconds.2nd relay switches for 3 secondsDelay time = 5 seconds

Relay 1

Delay

Relay 2

Display

Press the programming button

Display

It is possible to access the remainingprogramming points individuallyusing the scroll buttons.

Display

Press the programming button

Display

Press the programming button

Display

TIME

OK = Prog = Next

Relay

OK = Prog = Next

3 Sec

3 Sec

5 Sec

Relay

OK = Prog = Next

Release time

Relay 1 00m 03s

Release time

Relay 2 00m 04s

OK

OK

OK

Page 33: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

33

Time

The switching times for furtherrelays are programmed using thesame method. After programmingthe switching time for the last relay,the following display appears.

Use the programming button toenter the delay time programminglevel.

Enter the delay time, for example 5seconds, for the gateway using thescroll button . The cursor positionis modified using the cursor button

.

Confirm the entered value using theprogramming button.

Program the delay times for furthergateways using the same method.

After programming the delay timefor the last gateway, the followingdisplay appears:

Quit the release / delay timeprogramming level using the cancelbutton.

It is possible to terminate theprogramming session at any timewith the cancel button .

Display

or display if a gateway has beenprogrammed in the System menuunder „Gateway funct.“

Press the programming button

Display

Press the programming button

Display

Display

Press the cancel button

Display

button scrolls forward

button scrolls back

OK

OK

ESC

TIME

OK = Prog = Next

Relay

OK = Prog = Next

Delay time

Gateway B 00m

Delay time

Gateway A 00m 00s

Gateway

OK = Prog = Next

Relay

OK = Prog = Next

ESC

Page 34: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

34

Deletion

DeletionIn the Delete menu, it is possible todelete the codes, EKC/EK 601-... andgateways. The menu can only be accessed ifthe relevant data exists.

Programming example:

Depending on the existing dataentries, pressing the programmingbutton causes one of theprogramming points, for example„Delete code“ to appear.

If you do not wish code 01 to bedeleted, press the cancel button.

If you wish to delete code 01,confirm with the programmingbutton.

If you do not wish code 01 to bedeleted, press the cancel button.

If you really wish to delete code 01,confirm with the programmingbutton. Code 01 is then irretrievablydeleted.

The Delete menu contains thefollowing programming points

• Delete code word*• Delete code*• Delete card*• Delete gateway*

* These programming points onlyappear if the relevant data has beenprogrammed.

Display

Press the programming button

Display

Using the scroll buttons, it is possibleto access the further programmingpoints individually depending on theentered data (in our example, theprogramming point „Delete code“)

Display, if data exists also in otherprogramming points.

or display if, for example, data onlyexists in the programming point„Delete code“. This display alsoappears if the previous display wasconfirmed with the programmingbutton (OK).

Press the cancel button. The initialdisplay appears

Press the programming button

Display

Press the cancel button.The initialdisplay appears.

Press the programming button

DELETE

OK = Prog = Next

Delete code

OK = Prog = Next

Delete code

OK = Prog = Next

OK=Clr ESC=Can.

Code 01 X X X X X X X X

Delete: Are you sure?

OK=Yes ESC=No

ESC

ESC

OK

OK

OK

Page 35: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

35

Deletion

If there are several codes available,the next code appears in the display.Otherwise the next programmingpoint appears, e.g. „Delete card“.For additional deletion processes,the sequence described aboveapplies correspondingly.

Quit the programming level usingthe cancel button.

Programming can be terminated atany time using the cancel button .

Press the cancel button

Display

Display when all data has beendeleted

button scrolls forward

button scrolls back

ESC

DELETE

OK = Prog = Next

DELETE

No Data = Next

ESC

Page 36: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

36

Information

InformationIn the Information menu, theprogramming features of codes andthe EKC/EK 601-... can berequested.The Information menu contains thefollowing programming points:• Show code• Show card

Example

Pressing the programming buttoncauses the „Show code“ display toappear.

If you wish to display theprogramming features of certaincodes, confirm using theprogramming button.

Using the scroll button and thecursor button , enter the 1-8digit code number and then confirmwith the programming button.

Depending on the assignment, inthe bottom line of the displays, therelay functions L or G are displayed.

Use the scroll button to change tothe display.

Display

Press the programming button

Display

The programming points can beaccessed individually using the scrollbuttons.

Display

Press the programming button

Display

Press the programming button

Display without ECE 602-...

Display with ECE 602-...

Press the scroll button

INFORMATION

OK = Prog = Next

Show code

OK = Prog = Next

Show code

OK = Prog = Next

OK=Prog = Next

Code _

Relay 1 2

Code XX

Relay 1 2 3 4 5 6 7 8

Code XX

OK

OK

OK

Page 37: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

37

Information

Depending on the programmingconfiguration, the gatewayassignments are indicated in thebottom line of the displays.

Use the scroll buttons to change tothe display.

Depending on the programmingconfiguration, Yes or No is indicatedfor Disable with input 1 on thebottom line of the display.

Use the cancel button to return tothe initial display.

Every request sequence must beterminated with the cancel button

. No automatic indexing takesplace to the next request.

If you wish to request further codes,repeat the previous steps.

Start your request at the EKC/EK 601-... from the followingdisplay:

If you wish to have programmingfeatures of the EKC/EK 601-...displayed, confirm here with theprogramming button.

Confirm with the programmingbutton.

Display without ECE 602-...

Display with ECE 602-...if a gateway has been programmedin the System menu using theprogramming point „Gatewayfunct.“

Press the scroll button

Display

Press the cancel button

Display

Display

Press the programming button

Display

Press the programming button

OK

OK

ESC

Gateway A B

Code XX

Gateway A B C D

Code XX

Disable with inp.1

Code XX X X X

INFORMATION

OK = Prog = Next

Show card

OK = Prog = Next

OK=Prog = Next

Card 001

ESC

Page 38: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

38

Information

Further request points of the requestprocedure for EKC/EK 601-...correspond to those for requestingthe code.

Use the cancel button to return tothe initial display.

Programming can be continued atany time using the cancel button

.

Press the cancel button

Display

button scrolls forward

button scrolls back

INFORMATION

OK = Prog = Next

ESC

ESC

Page 39: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

39

Reset

ResetA reset routine deletes all inputsincluding the code word andrestores the default status.

A reset at the EC 602-.../ECE 602-... is carried out as follows:Switch off the supply voltage. Pressthe scroll buttons at the EC 602-... while switching thesupply voltage back on and continueto hold down the button during thefollowing display.

After around 7 seconds, the displayon the right appears. Then releasethe scroll button.

If you do not wish to delete the datapress the cancel button.

If you wish the data to be deleted,press the programming buttonwithin 5 seconds.

The following display appears:

If you do not wish to delete thedata, press the cancel button.

If you really wish to delete the data,press the programming buttonwithin 5 seconds.

The following display appears:

After a completed reset cycle, thebasic display appears again.

Display

Press the cancel button

Press the programming button

Display

Press the cancel button

Press the programming button

Display

Basic displaySSS Siedle

EC 602-0

Delete data

OK=Prog ESC=Can.

Delete: Are you sure?

OK=Yes ESC=No

SSS Siedle

Please wait

OK

OK

ESC

ESC

Page 40: Programming Instructions Entry Controller EC 602-01€¦ · 7 Programming Example with 1 COM 611- ... System with EC 602-... and 1 COM 611-... to actuate e.g. 1 door release via relay

© 1998/05.02Printed in GermanyBest. Nr. 0-1101/ 017235 GB

S. Siedle & Söhne

Postfach 1155D-78113 FurtwangenBregstraße 1D-78120 Furtwangen

Telefon +49 7723 63-0Telefax +49 7723 [email protected]