8
• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm • Installation must be inspected each year and an advi- sory measure and report must be available. • Installation must conform to ISO standards • Suitable for medium-and small teats • Suitable for high yielding dairy cows with quick-release: average milk speed from 2.5 kg / min and above • Uniform Building udder and teat implantation • Aeration in the jaw to close. (Glue, sticker, wall plugs) • Good and hygienic milking routine is very important • Milkmeter should regularly check the air holes • When stainless steel / plastic rings plastic rings • By default, IP-MV needs no additional weight • All lightweight claws • For very fast milking cows stainless steel rings • When milking cows tougher • Replacement of wash cups Recommended Set-up by Milk-Rite High line Mid line & robots Low line Machine vacuum 48 kPa 45 kPa 42 kPa Pulsation ratio 60:40 60:40 60:40 B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 ms D-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 ms Pulsation rate 60 bpm 60 bpm 60 bpm Recommended air consumption by Milk-Rite Per cluster Per liner Air consumption during washing 7,5 l / min 30 > 48 l / min Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / min Air consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min Recommended B-Phase to use maximum milking speed Claw Vacuum B-phase (ms) kPa “Hg 300 350 400 450 500 550 600 34 10.0 65% 70% 74% 77% 80% 81% 81% 36 10.5 68% 73% 77% 80% 81% 82% 82% 37 11.0 71% 75% 79% 82% 84% 84% 84% 39 11.5 74% 78% 82% 84% 86% 86% 86% 41 12.0 77% 82% 85% 87% 88% 88% 88% 42 12.5 81% 85% 88% 90% 91% 91% 90% 44 13.0 85% 89% 91% 93% 94% 93% 92% 46 13.5 89% 93% 95% 96% 97% 96% 94% 47 14.0 93% 97% 99% 100% 100% 99% 97% Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition Replacement For TLC range TLC-FW1, TLC-ST1 Fullwood range FW38U, FW68U, FW69U Manus range MS031U, MS197U, MS897U, MS163U Gascone Melotte range GM22U, GM99U Suitable for following claws Westfalia range Magnum 450 Fullwood range Freeway InterPuls range Orbiter, Lunik Manus range Optimum Gascone Melotte range Isolac TRIANGULAR MOUTHPIECE VENTED LINERS PRODUCT RANGE IP10U-AIR - Triangular Liners & Shells

product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

TLC range TLC-FW1, TLC-ST1Fullwood range FW38U, FW68U, FW69U

Manus range MS031U, MS197U, MS897U, MS163UGascone Melotte range GM22U, GM99U

Suitable for following claws

Westfalia range Magnum 450Fullwood range FreewayInterPuls range Orbiter, Lunik

Manus range OptimumGascone Melotte range Isolac

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp10u-aIr - triangular Liners & Shells

Page 2: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

Orion range O23U

Sutable for following claws

Westfalia range Magnum 450InterPuls range Orbiter, LunikFullwood range FreewayStrangko range Strangko claws

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp10u-01-aIr - triangular Liners & Shells

Page 3: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

SAC range SAC012U, SAC010U, SAC020U, SAC022U

Sutable for following claws

SAC range UnifolwInterPuls range Orbiter, Lunik, Galaxy (15 mm nipple)Fullwood range Eva

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp11u-aIr - triangular Liners & Shells

Page 4: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

Gascone Melotte range GM16U, GM2U, GM74U, GM75UFullwood range FW14U, FW27U, FW37U, FW46U, FW67U

DeLaval range DL000U, DL001U, DL016U, DL017U, DL017U-01, DL178U, DL179U, DL295U

SAC range SAC007UDairy Master range DM916U

Manus range MS123U, MS390U

Sutable for following claws

DeLaval range Hydropuls 8 mm, HCC 150 8 mm, HCC 150 9,5 mm; MC 31 10 mm; SAC Innenstutzen 8 mm

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp12u-aIr - triangular Liners & Shells

Page 5: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

TLC Range TLC-A3, TLC-A5, TLC-A6

DeLaval range DL009U, Dl007U, DL007U-01, DL008U, DL4007U, AL6U, DL036U, DL37U, DL037U-01

Sutable for following claws

DeLaval range TF 350/360, ATF 450, MC 93Fullwood range Eva

SAC range UniflawInterPuls range Orbiter, Lunik, Galaxy (15 mm nipple)

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp13u-aIr - triangular Liners & Shells

Page 6: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

TLC Range TLC-W2

Westfalia range WS10U, WS120U, WS150U, WS220U, WS230U, WS270U-01, WS3-100U, WS3-110U

Fullwood range FW22U,MEL range MEL278U, MEL450U

Sutable for following claws

Westfalia range Classic 330 clFit on every cluster with appropriate short milk tube with sight glass

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp14u-aIr - triangular Liners & Shells

Page 7: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

TLC Range TLC-BX1, Manus range MS390U, MS507U,

Boumatic range BM1XU, BMFMU, BMEXUWestfalia range WS025U, WS029U, WS240U, WS27U

DeLaval range DL295U-10

Gascone Melotte range GM85U, GM86U, GM88U, GM89U, GM91U, GM93U, GM95U

Sutable for following claws

Boumatic range Flo MAX Star, Flo StarWestfalia range Classic 330 cl

DeLaval range HCC 150 9,5 mm, MC 31 10 mmInterPuls range Lunik, Orbiter

Gascone Melotte range Isolac (claw angled nipple)Germania range Germania clawsFullwood range Freeway

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp15u-aIr - triangular Liners & Shells

Page 8: product range TRIANGULAR MOUTHPIECE VENTED LINERS Ip10u … · 2013. 6. 26. · • Good and hygienic milking routine is very important • Milkmeter should regularly check the air

• Minimum pipe diameter Milk: minimum 50 mm, from 6 clusters: 60 mm, from 12 clusters: 76 mm

• Installation must be inspected each year and an advi-sory measure and report must be available.

• Installation must conform to ISO standards• Suitable for medium-and small teats• Suitable for high yielding dairy cows with quick-release:

average milk speed from 2.5 kg / min and above• Uniform Building udder and teat implantation• Aeration in the jaw to close. (Glue, sticker, wall plugs)• Good and hygienic milking routine is very important

• Milkmeter should regularly check the air holes• When stainless steel / plastic rings

plastic rings• By default, IP-MV needs no additional weight• All lightweight claws• For very fast milking cows

stainless steel rings• When milking cows tougher• Replacement of wash cups

Recommended Set-up by Milk-Rite

High line Mid line & robots Low lineMachine vacuum 48 kPa 45 kPa 42 kPa

Pulsation ratio 60:40 60:40 60:40B-Phase range 400 - 450 ms 400 - 450 ms 400 - 450 msD-Phase range 250 - 280 ms 250 - 280 ms 250 - 280 msPulsation rate 60 bpm 60 bpm 60 bpm

Recommended air consumption by Milk-Rite

Per cluster Per linerAir consumption during washing 7,5 l / min 30 > 48 l / min

Air consumption during milking in simultaneous pulsation 4 > 5,5 l / min 16 > 20 l / minAir consumption during milking pulsating alternating 4 > 5,5 l / min 8 > 11 l / min

Recommended B-Phase to use maximum milking speed

Claw Vacuum B-phase (ms)kPa “Hg 300 350 400 450 500 550 60034 10.0 65% 70% 74% 77% 80% 81% 81%36 10.5 68% 73% 77% 80% 81% 82% 82%37 11.0 71% 75% 79% 82% 84% 84% 84%39 11.5 74% 78% 82% 84% 86% 86% 86%41 12.0 77% 82% 85% 87% 88% 88% 88%42 12.5 81% 85% 88% 90% 91% 91% 90%44 13.0 85% 89% 91% 93% 94% 93% 92%46 13.5 89% 93% 95% 96% 97% 96% 94%47 14.0 93% 97% 99% 100% 100% 99% 97%

Milking Speed (% of MAXIMUM) - not using IP liners maximum benefits; - maximum speed, but concrete some teat end problems; - maximum speed and very good teat end condition

Replacement For

TLC Range TLC-BX1, Manus range MS390U, MS507U,

Boumatic range BM1XU, BMFMU, BMEXUWestfalia range WS025U, WS029U, WS240U, WS27U

DeLaval range DL295U-10

Gascone Melotte range GM85U, GM86U, GM88U, GM89U, GM91U, GM93U, GM95U

Sutable for following claws

Boumatic range Flo MAX Star, Flo StarWestfalia range Classic 330 cl

DeLaval range HCC 150 9,5 mm, MC 31 10 mmInterPuls range Lunik, Orbiter

Gascone Melotte range Isolac (claw angled nipple)Germania range Germania clawsFullwood range Freeway

TRIANGULAR MOUTHPIECE VENTED LINERSproduct rangeIp4LM-aIr - triangular Liners & Shells