18
REPRESENTATIVE CUSTOMER SHEET TITLE SHEET NO. PROJECT TITLE PRODUCT DRWN DATE CHECK PROJECT LOCATION SHEET REFERENCE 06/28/21 A.D. D.T. ARCHITECT Only the products that are identified as such on this document are FSC ® certified CertainTeed Ceiling Corporation 20 Moores Road Malvern, PA 19355 800-233-8990 Certificate Code: SCS-COC-006960 R F S C The mark of responsible forestry FSC C151918 R DATE REVISIONS # These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability for the accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services. THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED. Ceiling Backer/Dowel Grille 4215BD Backer/Dowel Grille PD-00 Backer Grille 4215BD Product Detail Set PD-01: Product Details and Basic Installation A. Backer/Dowel Grille Section View B. Backer/Dowel Grille Back View C. Isometric Installation Diagram View PD-01a: Backer/Blind Blade Dowel Grille Produce Details A. Backer/Blind Blade Dowel Grille Section View B. Backer/Blind Blade Dowel Grille Back View PD-10: Typical Suspension System Layout A. Typical Suspension System Layout Isometric View PD-11: Typical Installation Details A. Perimeter Edge Detail - Parallel B. Perimeter Edge Detail - Perpendicular C. Installation Field Cut Diagram Isometric View PD-12: Alternate Perimeter Options A. Floating Edge Detail - Parallel B. Floating Edge Detail - Perpendicular See PD-13, PD-14, PD-15: Grille Mounted Perimeter Trim Installation See PD-16, PD-17, PD-18 for Suspension System Mounted Perimeter Trim PD-13: Grille Mounted Perimeter Trim Installation (see PD-16, PD-17, PD-18 for Suspension System Mounted Perimeter Trim) A. Backer/Dowel Grille Mounted Perimeter Trim Detail - Parallel B. Backer/Dowel Grille Mounted Perimeter Trim Detail - Perpendicular C. Backer/Dowel Grille Mounted Trim Installation Back View PD-14: Grille Mounted Perimeter Trim Installation (see PD-16, PD-17, PD-18 for Suspension System Mounted Perimeter Trim) A. Backer/Dowel Grille Mounted Perimeter Trim Installation Isometric Back View PD-15: Grille Mounted Perimeter Trim Installation (see PD-16, PD-17, PD-18 for Suspension System Mounted Perimeter Trim) A. Backer/Dowel Grille Mounted Perimeter Trim Installation Isometric Face View PD-16: Suspension System Mounted Perimeter Trim Installation (see PD-13, PD-14, PD-15) for Grille Mounted Perimeter Trim) A. Suspension System Mounted Perimeter Trim Detail - Parallel. B. Suspension System Mounted Perimeter Trim Detail - Perpendicular. C. Suspension System Mounted Trim Installation Back View PD-17: Suspension System Mounted Perimeter Trim Installation (see PD-13, PD-14, PD-15 for Grille Mounted Perimeter Trim) A. Suspension System Mounted Perimeter Trim Installation Isometric Back View PD-18: Suspension System Mounted Perimeter Trim Installation (see PD-13, PD-14, PD-15 for Grille Mounted Perimeter Trim) A. Suspension System Mounted Perimeter Trim Installation Isometric Face View PD-19: Fixture Integration and Access Panels. A. Enlarged Back View at Maintenance Panel . B. Maintenance Panel Detail - Perpendicular. C. Maintenance Panel Detail - Parallel. D. Linear Light Fixture Detail - Parallel. E. Light Fixture Detail - Parallel F. Sprinkler Detail PD-20: Horizontal Direct Mount Wall Installation. A. Horizontal Direct Mount Attachment to Wall Furring. B. Horizontal Direct Mount Attachment to Wall Furring Section PD-21: Vertical Direct Mount Wall Installation. A. Vertical Direct Mount Attachment to Wall Furring. B. Vertical Direct Mount Attachment to Wall Furring Section PD-22: Horizontal Z-Clip/Z-Bar Wall Installation. A. Horizontal Z-Clip/Z-Bar Mount Attachment to Wall. B. Horizontal Z-Clip/Z-Bar Mount Attachment to Wall Section. PD-23: Vertical Z-Clip/Z-Bar Wall Installation. A. Vertical Z-Clip/Z-Bar Mount Attachment to Wall. B. Vertical Z-Clip/Z-Bar Mount Attachment to Wall Section PD-24: CISCA Tolerances, Product Notes, and Ordering Notes Product Detail Set Contents: Product Specifications Ceiling Backer/Dowel Grille Backer: 1/2" x 1 1/4" x 12" - Black Nominal Size 12" x 96" Fire Performance: ASTM E84 (Class A) & CAN/ULC-S102: FS 200 or less, SD 450 or less; Fire-Retardant Coating Available (E84 Class A): FS 25 or less, SD 450 or less Finish: Clear Top coat, 20% sheen Core: 5/8" Solid Wood Module: Type: Backer/Dowel Grille Module (Ceiling) Board Specs.: Species: Solid Wood Species 5/8" x 2-1/4", 6 Boards/Module Screw through backer to 15/16" CertainTeed T-Bar (Optional C-124 Backer Clip) Mounting: Accessories: Felt, Nonwoven, Screen, or Thermoplastic Backing (Optional) Dowel: Solid Wood Dowel Ø1/2" x 12" - Black

Product Detail Set Contents: Ceiling Backer/Dowel Grille

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Product Detail Set Contents: Ceiling Backer/Dowel Grille

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-00

Backer Grille 4215BDProduct Detail Set

PD-01: Product Details and Basic InstallationA. Backer/Dowel Grille Section ViewB. Backer/Dowel Grille Back ViewC. Isometric Installation Diagram View

PD-01a: Backer/Blind Blade Dowel Grille Produce DetailsA. Backer/Blind Blade Dowel Grille Section ViewB. Backer/Blind Blade Dowel Grille Back View

PD-10: Typical Suspension System LayoutA. Typical Suspension System Layout Isometric View

PD-11: Typical Installation DetailsA. Perimeter Edge Detail - ParallelB. Perimeter Edge Detail - PerpendicularC. Installation Field Cut Diagram Isometric View

PD-12: Alternate Perimeter OptionsA. Floating Edge Detail - ParallelB. Floating Edge Detail - Perpendicular

See PD-13, PD-14, PD-15: Grille Mounted Perimeter TrimInstallationSee PD-16, PD-17, PD-18 for Suspension System MountedPerimeter Trim

PD-13: Grille Mounted Perimeter Trim Installation(see PD-16, PD-17, PD-18 for Suspension System MountedPerimeter Trim)A. Backer/Dowel Grille Mounted Perimeter Trim Detail - ParallelB. Backer/Dowel Grille Mounted Perimeter Trim Detail -

PerpendicularC. Backer/Dowel Grille Mounted Trim Installation Back View

PD-14: Grille Mounted Perimeter Trim Installation(see PD-16, PD-17, PD-18 for Suspension System MountedPerimeter Trim)A. Backer/Dowel Grille Mounted Perimeter Trim Installation

Isometric Back View

PD-15: Grille Mounted Perimeter Trim Installation(see PD-16, PD-17, PD-18 for Suspension System MountedPerimeter Trim)A. Backer/Dowel Grille Mounted Perimeter Trim Installation

Isometric Face View

PD-16: Suspension System Mounted Perimeter Trim Installation(see PD-13, PD-14, PD-15) for Grille Mounted Perimeter Trim)A. Suspension System Mounted Perimeter Trim Detail - Parallel.B. Suspension System Mounted Perimeter Trim Detail -

Perpendicular.C. Suspension System Mounted Trim Installation Back View

PD-17: Suspension System Mounted Perimeter Trim Installation(see PD-13, PD-14, PD-15 for Grille Mounted Perimeter Trim)A. Suspension System Mounted Perimeter Trim Installation

Isometric Back ViewPD-18: Suspension System Mounted Perimeter Trim Installation(see PD-13, PD-14, PD-15 for Grille Mounted Perimeter Trim)A. Suspension System Mounted Perimeter Trim Installation

Isometric Face View

PD-19: Fixture Integration and Access Panels.A. Enlarged Back View at Maintenance Panel.B. Maintenance Panel Detail - Perpendicular.C. Maintenance Panel Detail - Parallel.D. Linear Light Fixture Detail - Parallel.E. Light Fixture Detail - ParallelF. Sprinkler Detail

PD-20: Horizontal Direct Mount Wall Installation.A. Horizontal Direct Mount Attachment to Wall Furring.B. Horizontal Direct Mount Attachment to Wall Furring Section

PD-21: Vertical Direct Mount Wall Installation.A. Vertical Direct Mount Attachment to Wall Furring.B. Vertical Direct Mount Attachment to Wall Furring Section

PD-22: Horizontal Z-Clip/Z-Bar Wall Installation.A. Horizontal Z-Clip/Z-Bar Mount Attachment to Wall.B. Horizontal Z-Clip/Z-Bar Mount Attachment to Wall Section.

PD-23: Vertical Z-Clip/Z-Bar Wall Installation.A. Vertical Z-Clip/Z-Bar Mount Attachment to Wall.B. Vertical Z-Clip/Z-Bar Mount Attachment to Wall Section

PD-24: CISCA Tolerances, Product Notes, and Ordering Notes

Product Detail Set Contents:Product SpecificationsCeiling Backer/Dowel Grille

Backer: 1/2" x 1 1/4" x 12" - Black

Nominal Size 12" x 96"

FirePerformance:

ASTM E84 (Class A) & CAN/ULC-S102: FS 200or less, SD 450 or less; Fire-Retardant CoatingAvailable (E84 Class A): FS 25 or less, SD 450or less

Finish: Clear Top coat, 20% sheen

Core: 5/8" Solid Wood

Module:Type: Backer/Dowel Grille Module (Ceiling)

Board Specs.:

Species: Solid Wood Species

5/8" x 2-1/4", 6 Boards/Module

Screw through backer to 15/16" CertainTeedT-Bar (Optional C-124 Backer Clip)

Mounting:

Accessories: Felt, Nonwoven, Screen, or Thermoplastic

Backing (Optional)

Dowel: Solid Wood Dowel Ø1/2" x 12" - Black

Page 2: Product Detail Set Contents: Ceiling Backer/Dowel Grille

1058" O/S-O/S

Cross Tee2'-0"O.C.

Cross Tee2'-0"O.C.

Cross Tee2'-0"O.C.

Cross Tee1'-0"O.C.

512" Max.

Cantilever

7'-11"OVERALL

14" 1'-0" O/S-O/S

158"

MainRunner

4'-0"O.C.

512" Max.

Cantilever

APD-01

1/2" Backer

114"

Ø12"

1/2" WoodDowel

Solid WoodFinished Face,

& Sealed Ends.

APD-01

1/2" Backer - Black1'-0"1

4"21 4" B

oard23

4"

1'-0"Nominal

2" O.C.

138" Reveal 5

8"

Solid Wood FinishedFace & Sealed Ends.

Starting Edgeof Next Blade

1/2" WoodDowel - Black

Starting Edgeof Next Blade

1516"

[MAX]Ø1

2"

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

MODULE QTY.:

--

Quantity does not reflect closetstock or spares

Product Specifications

Screw through backer to 15/16" CertainTeed T-Bar(Optional Backer Clips (C-124))

Backer: 1/2" x 1 1/4" x 12" - Black

Nominal Size 12" x 95"

Finish: Clear Top coat, 20% sheen

Mounting:

Core: 5/8" Solid Wood

Accessories: Felt, Nonwoven, Screen, or Thermoplastic

Backing (Optional)

Module:Type:

Board Specs.:

Species: Solid Wood Species

5/8" x 2-1/4", 6 Boards/Module

APD-01

4215BD Backer/Dowel Grille Section ViewScale: 3"=1'-0"

BPD-01

4215BD Backer/Dowel Grille Back ViewScale: 3/4"=1'-0"

CPD-01

4215BD Isometric Installation Diagram ViewScale: 1/2"=1'-0"

Minimum 1/2" Reveal to Allowfor Expansion/Contraction

CertainTeed 15/16"HD Cross Tee

Grille BackerModule

1" Reveal BetweenGrille Module

CertainTeed 15/16" HDMain Runner 48" O.C.

Flat backers

5-1/2" Max.Cantilever

CertainTeed 15/16"Heavy Duty MainRunners (48" O.C.)

Optional BackerClips (C-124)

#6 1-1/4" Hi Lo BugleHead ScrewsFasteners 12" to 24"o.c. by Others

Ceiling Backer/Dowel Grille

Product Details and BasicInstallation

4215BD Backer/Dowel Grille

Ceiling Backer/Dowel Grille

Backer/Dowel Grille Module (Ceiling)

Dowel: Solid Wood Dowel Ø1/2" x 12" - Black

Grille Backer/DowelModule Ready toInstall

Solid Wood Dowel

Optional Acoustical Infill Panel

Fire Performance: ASTM E84 (Class A) & CAN/ULC-S102: FS 200 orless, SD 450 or less; Fire-Retardant CoatingAvailable (E84 Class A): FS 25 or less, SD 450 or less

Felt, Nonwoven, Screen,

or Thermoplastic

Backing (Optional)

PD-01

Page 3: Product Detail Set Contents: Ceiling Backer/Dowel Grille

1058" O/S-O/S

Cross Tee2'-0"O.C.

Cross Tee2'-0"O.C.

Cross Tee2'-0"O.C.

Cross Tee1'-0"O.C.

512" Max.

Cantilever

7'-11"OVERALL

14" 1'-0" O/S-O/S

158"

MainRunner

4'-0"O.C.

512" Max.

Cantilever

APD-01A

1/2" Backer

114"

Ø12"

1/2" WoodDowel

Solid WoodFinished Face,

& Sealed Ends.

Blind Blade

APD-01A

1/2" Backer - Black1'-0"1

4"21 4" B

oard23

4"

1'-0"Nominal

2" O.C.

138" Reveal 5

8"

Solid Wood FinishedFace & Sealed Ends.

Starting Edgeof Next Blade

1/2" WoodDowel - Black

Starting Edgeof Next Blade

1516"

[MAX]Ø1

2"

Blind Blade

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

APD-01A

4215BD Backer/Blind Blade Dowel Grille Section ViewScale: 3"=1'-0"

BPD-01A

4215BD Backer/Blind Blade Dowel Grille Back ViewScale: 3/4"=1'-0"

Backer/Blind Blade DowelGrille Produce Details

4215BD Backer/Dowel Grille

Ceiling Backer/Dowel Grille

PD-01A

Page 4: Product Detail Set Contents: Ceiling Backer/Dowel Grille

12' CertainTeed 15/16"HD Main Runner(EZCS12-12-20) 48" O.C.

4' CertainTeed 15/16"HD Cross Tee(EZCS4-12-20)

HangerWires(HW12)

2' CertainTeed15/16" HD Cross Tee

(EZCS2-12-20)

2' CertainTeed15/16" HD Cross Tee(EZCS2-12-20)

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-10

APD-10

4215BD Typical Suspension System Layout Isometric ViewScale: 1/2"=1'-0"

Typical Suspension SystemLayout

Page 5: Product Detail Set Contents: Ceiling Backer/Dowel Grille

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer

138" Reveal

CertainTeed HD MainRunner 48" O.C.

CertainTeed WallAngle (WA-14-14)

Reveal to match panelReveal (Additional perimeter

options, see PD-12)

#6 1-1/4" Hi Lo BugleHead ScrewsFasteners 12" to 24"o.c. by Others

CertainTeed 15/16"HD Cross Tee

Optional Backer Clip (C-124)

Optional BackerClip (C-124)

Grille Ready to Install1/2" Wood Dowel

Solid WoodFinished Face& Sealed Ends.

1/2" Backer

CertainTeed 15/16" HDCross Tee

CertainTeed WallAngle (WA-14-14)

Reveal to match panelReveal (Additional perimeter

options, see PD-12)

CertainTeed HD MainRunner 48" O.C.

FieldModificationBacker, Appliedin the Field Priorto Cutting Planks

Field Trim PanelEnd by Others

1/2" Wood Dowel

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-11

APD-11

4215BD Perimeter Edge Detail - ParallelScale: 3"=1'-0"

CPD-11

4215BD Installation Field Cut Diagram Isometric ViewScale: 1/2"=1'-0"

BPD-11

4215BD Perimeter Edge Detail - PerpendicularScale: 3"=1'-0"

Grid Guidelines:

Install panels by attaching with fasteners directly through flat backers intoCertainTeed Heavy Duty Main Runners and parallel Cross Tees every 24" O.C., or useoptional Backer Clip (C-124).

Maximum cantilever from plank end to last Main Tee is 6". Note that additional MainRunners or Cross Tees may be needed in certain configurations.

Cross Tee Required 24" O.C. between Main Runners.

Field modified panels must attach to a minimum of (2) Main Runners - or usealternative attachment method. Loose backers provided for field modified panels.

Typical Installation Details

CertainTeed 15/16"HD Cross Tee

Attach Small Plank Pieces with1/2" Black Backer to Back of

Adjacent Panel. by Others

Seal Cut Edgeswith Factory

ProvidedSealant

Field ModificationBackers Applied as

Needed

CertainTeed 15/16"Heavy Duty MainRunners (48" O.C.)

Seal Cut Edgeswith FactoryProvided Sealant

Field Modification Backer, Appliedin the Field Prior to Cutting Planks

Page 6: Product Detail Set Contents: Ceiling Backer/Dowel Grille

1/2" Backer

CertainTeed 15/16" HDMain Runner 48" O.C.

CertainTeed 15/16" HDCross Tee

Hanger Wires (HW12)

1/2" Wood Dowel

1/2" Backer

CertainTeed 15/16"HD Cross Tee

CertainTeed 15/16" HDMain Runner 48" O.C.

Hanger Wires (HW12)

1/2" Wood Dowel

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-12

Alternate PerimeterOptions

BPD-12

4215BD Floating Edge Detail - PerpendicularScale: 3"=1'-0"

APD-12

4215BD Floating Edge Detail - ParallelScale: 3"=1'-0"

Page 7: Product Detail Set Contents: Ceiling Backer/Dowel Grille

Solid Wood FinishedFace & Sealed Ends.

58"

6" T

rim

90° PerimeterTrim Bracket(C-116)

Reveal to matchpanel Reveal

1/2" Backer

CertainTeed 15/16" HDMain Runner 48" O.C.

CertainTeed 15/16" HDCross Tee

1/2" Wood Dowel

Solid Wood FinishedFace & Sealed Ends.

CertainTeed 15/16"HD Cross Tee

CertainTeed 15/16" HDMain Runner 48" O.C.

58"

6" T

rim

90° PerimeterTrim Bracket(C-116)

Reveal to matchpanel Reveal 1/2" Wood Dowel

1/2" Backer

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-13

APD-13

4215BD Backer/Dowel Grille Mounted Perimeter Trim Detail - ParallelScale: 3"=1'-0"

BPD-13

4215BD Backer/Dowel Grille Mounted Perimeter Trim Detail - PerpendicularScale: 3"=1'-0"

CPD-13

4215BD Backer/Dowel Grille Mounted Trim Installation Back ViewScale: 1/2"=1'-0"

Grille Mounted Perimeter TrimInstallation (see PD-16, PD-17,PD-18 for Suspension SystemMounted Perimeter Trim)

CertainTeed 15/16"HD Cross Tee

3" SplicePlate C-100

CertainTeed 15/16"Heavy Duty MainRunners (48" O.C.)

4" Trim

90° Perimeter TrimBracket (C-116)

1" Min Reveal

Suggested ComponentCertainTeed SmartFit Yoke (SFYK)D

PD-19A

PD-13

BPD-13

Light Fixtureby Others

Field Cut 1/2" Min. LinearPanel & Access Panel

Reveal Between & LightFixture

EPD-19

Field Modification Backers FieldApplied as Needed and Before

Cutting Panels

Maintenance Panel

APD-19

Grille Backer/Dowel Panel

Field Cut 1/2" Min. RevealBetween Field Cut 1/2" Min.Panel & Maintenance Panel

Optional BackerClips (C-124)

Splice Plate C-101

Page 8: Product Detail Set Contents: Ceiling Backer/Dowel Grille

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-14

APD-14

4215BD Backer/Dowel Grille Mounted Isometric Trim Installation Back ViewScale: 3/4"=1'-0"

Grille Mounted Perimeter TrimInstallation (see PD-16, PD-17,PD-18 for Suspension SystemMounted Perimeter Trim)

CertainTeed 15/16"HD Cross Tee

3" SplicePlate C-100

CertainTeed 15/16"Heavy Duty MainRunners (48" O.C.)

1" Min Reveal

Field Modification Backers FieldApplied as Needed and Before

Cutting Panels

Grille Backer/Dowel Panel

Field Cut 1/2" Min. RevealBetween Field Cut 1/2" Min.Panel & Maintenance Panel

3" SplicePlate C-100

4" TrimField Installed

Optional BackerClips (C-124)

90° Perimeter TrimBracket (C-116)

Field Installed

Maintenance Panel

Suggested ComponentCertainTeed SmartFit Yoke

(SFYK)

Light Fixtureby Others

1/2" Min Reveal BetweenPanels & Trim.

Light Fixture by Others

Field Cut 1/2" Min. Panel & RevealBetween Panel & Light Fixture

Field Modification Backers FieldApplied as Needed and Before

Cutting Panels

Hanger Wires 48" O.C.; Hanger Wires < 6"from Perimeter Trim Attachments

Note: All fixtures such as sprinklers, lights,cameras, speakers etc. must be suspended

independently of the wood ceiling.

Splice Plate C-101

1/2" Wood Dowel

Page 9: Product Detail Set Contents: Ceiling Backer/Dowel Grille

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-15

APD-15

4215BD Backer/Dowel Grille Mounted Isometric Trim Installation Face ViewScale: 3/4"=1'-0"

Grille Mounted Perimeter TrimInstallation (see PD-16, PD-17,PD-18 for Suspension SystemMounted Perimeter Trim)

CertainTeed 15/16" HD MainRunners 48" O.C. with CrossTees 24" from Main Runners withCross Tees 12" O.C. as Needed

1" Min Reveal

Field Cut 1/2" Min. RevealBetween Field Cut 1/2" Min.Panel & Maintenance Panel

4" TrimField Installed

Maintenance Panel

Light Fixtureby Others

1/2" Min Reveal BetweenPanels & Trim.

Grille Backer/Dowel Panel

Light Fixtureby Others

Backer/Dowel

Page 10: Product Detail Set Contents: Ceiling Backer/Dowel Grille

CertainTeed 15/16" HDMain Runner 48" O.C.

CertainTeed 15/16" HDCross Tee

Perimeter Clip(CTSPC-2)

CertainTeed WallAngle (WA-14-14)

Solid Wood FinishedFace & Sealed Ends.

58"

6" T

rim

Reveal to matchpanel Reveal

1/2" Backer

1/2" Wood Dowel

Solid Wood FinishedFace & Sealed Ends.

58"

6" T

rim

Reveal to matchpanel Reveal

CertainTeed 15/16" HDMain Runner 48" O.C.

CertainTeed 15/16" HDCross Tee

Perimeter Clip(CTSPC-2)

CertainTeed WallAngle (WA-14-14)

1/2" Wood Dowel

1/2" Backer

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-16

CertainTeed 15/16"HD Cross Tee

3" SplicePlate C-100

CertainTeed 15/16"Heavy Duty MainRunners (48" O.C.)

4" Trim1" Min Reveal

Suggested ComponentCertainTeed SmartFit Yoke (SFYK)

DPD-19

APD-16

BPD-16

Light Fixtureby Others

Field Cut 1/2" Min. LinearPanel & Access Panel

Reveal Between & LightFixture

EPD-19

Field Modification Backers FieldApplied as Needed and Before

Cutting Panels

Maintenance Panel

APD-19

Grille Backer/Dowel Panel

Field Cut 1/2" Min. RevealBetween Field Cut 1/2" Min.Panel & Maintenance Panel

CPD-16

4215BD Suspension System Mounted Perimeter Trim Installation Back ViewScale: 1/2"=1'-0"

APD-16

4215BD Suspension System Mounted Perimeter Trim Detail - ParallelScale: 3"=1'-0"

BPD-16

4215BD Suspension System Perimeter Trim Detail - PerpendicularScale: 3"=1'-0"

Optional Trim Attachment Optional Trim Attachment

Optional Trim Attachment

Perimeter Clip(CTSPC-2)

CertainTeed WallAngle (WA-15-15)

Suspension System MountedPerimeter Trim Installation(see PD-13, PD-14, PD-15) forGrille Mounted Perimeter Trim)

Optional BackerClips (C-124)

Splice Plate C-101

Page 11: Product Detail Set Contents: Ceiling Backer/Dowel Grille

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-17

APD-17

4215BD Suspension System Mounted Perimeter Trim Installation Isometric Back ViewScale: 3/4"=1'-0"

CertainTeed 15/16"HD Cross Tee

3" SplicePlate C-100

CertainTeed 15/16"Heavy Duty MainRunners (48" O.C.)

1" Min Reveal

Field Modification Backers FieldApplied as Needed and Before

Cutting Panels

Grille Backer/Dowel Panel

Field Cut 1/2" Min. RevealBetween Field Cut 1/2" Min.Panel & Maintenance Panel

3" SplicePlate C-100

4" TrimField Installed

Optional BackerClips (C-124)

Perimeter Clip(CTSPC-2)

Maintenance Panel

Suggested ComponentCertainTeed SmartFit Yoke

(SFYK)

Light Fixtureby Others

1/2" Min Reveal BetweenPanels & Trim.

Light Fixture by Others

Field Cut 1/2" Min. Panel & RevealBetween Panel & Light Fixture

Field Modification Backers FieldApplied as Needed and Before

Cutting Panels

Suspension System MountedPerimeter Trim Installation(see PD-13, PD-14, PD-15) forGrille Mounted Perimeter Trim)

Hanger Wires 48" O.C.; Hanger Wires < 6"from Perimeter Trim Attachments

Optional Trim Attachment

Note: All fixtures such as sprinklers, lights,cameras, speakers etc. must be suspended

independently of the wood ceiling.

Splice Plate C-101

Page 12: Product Detail Set Contents: Ceiling Backer/Dowel Grille

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-18

APD-18

4215BD Suspension System Mounted Perimeter Trim Installation Face ViewScale: 3/4"=1'-0"

CertainTeed 15/16" HD MainRunners 48" O.C. with CrossTees 24" from Main Runners withCross Tees 12" O.C. as Needed

1" Min Reveal

Field Cut 1/2" Min. RevealBetween Field Cut 1/2" Min.Panel & Maintenance Panel

4" TrimField Installed

Maintenance Panel

Light Fixtureby Others

1/2" Min Reveal BetweenPanels & Trim.

Grille Backer/Dowel Panel

Light Fixtureby Others

Optional Trim Attachment

Suspension System MountedPerimeter Trim Installation(see PD-13, PD-14, PD-15) forGrille Mounted Perimeter Trim)

Page 13: Product Detail Set Contents: Ceiling Backer/Dowel Grille

BPD-19

CPD-19

Field ModificationBackers Field

Applied as Neededand Before Cutting

Panels

Maintenance Panel

Field Cut 1/2" Min.Reveal BetweenLinear Panel &Access Panel

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer CertainTeed 15/16" HDCross Tee (Beyond)

CertainTeedHD MainRunner 48" O.C.

Field Modification Backer, appliedin the field prior to cutting planks

Field Trim PanelEnds as needed

Field Trim PanelEnds as needed

Reveal tomatch panel

Reveal

Seal Cut Edgeswith Factory

Provided Sealant

Seal Cut Edgeswith Factory

Provided Sealant

Reveal tomatch panel

Reveal

1/2" Wood Dowel

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer(Beyond)

CertainTeed 15/16"HD Cross Tee

CertainTeed HD MainRunner 48" O.C. (Beyond)

Field Modification Backer, Appliedin the Field Prior to Cutting Planks

Standard Grille

Field ModifiedMaintenance Panel

1/2" Wood DowelStained Black (Beyond)

SuggestedComponentCertainTeedSmartFit Yoke

(SFYK)CertainTeed 15/16"HD Cross Tee

CertainTeedHD Main

Runner 48"O.C.

Light Fixtureby Others

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer

Field ModifiedGrille Panel

CertainTeed HD MainRunner 48" O.C. (Beyond)

Solid Wood FinishedFace & Sealed Ends.

Field Cut 1/2" Min.Reveal Between LinearPanel & Light Fixture

Field Modification Backers(Beyond)FieldApplied as Needed and Before Cutting Panels

Light Fixtureby Others

CertainTeed 15/16" HDSuspension System

Fire Sprinkler by Others

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-19

APD-19

4215BD Enlarged Back View at Maintenance PanelScale: 1-1/2"=1'-0"

Fixture Integration andAccess Panels

BPD-19

4215BD Maintenance Panel Detail - PerpendicularScale: 3"=1'-0"

CPD-19

4215BD Maintenance Panel Detail - ParallelScale: 3"=1'-0"

DPD-19

4215BD Linear Light Fixture Detail - ParallelScale: 3"=1'-0"

EPD-19

4215BD Light Fixture Detail - ParallelScale: 3"=1'-0"

FPD-19

Sprinkler DetailScale: 3"=1'-0"

Note: All fixtures such as

sprinklers, lights, cameras,

speakers etc. must be

suspended independently

of the wood ceiling.

Page 14: Product Detail Set Contents: Ceiling Backer/Dowel Grille

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer

Fasteners by Others

Grille Backer/DowelModule Ready toInstall

Fasteners 12" to 24"O.C. by Others

Furring by Installer

Structural Wall by Others

234"

1/2" Wood Dowel

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215B6 Backer/Dowel Grille

PD-20

APD-20

4215B6 Horizontal Direct Mount Attachment to Wall FurringScale: 1/2"=1'-0"

Horizontal Direct MountWall Installation

BPD-20

4215B6 Horizontal Direct Mount Attachment to Wall Furring SectionScale: 3"=1'-0"

Note: Wall Mounted Panels aremade with 1-1/4" Wide Backers

Wall Furring to Alignwith Panel Backers

Fasteners12" to 24" O.C.by Others

Grille Backer/DowelModule Ready to

Install

Page 15: Product Detail Set Contents: Ceiling Backer/Dowel Grille

Fasteners byOthers

Grille Backer/DowelModule Ready to Install

Furring by Installer

Structural Wallby Others

Fasteners 12" to 24" O.C. by Others

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer

Grille PanelReady to Install

234"

1/2" Wood Dowel

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215B6 Backer/Dowel Grille

PD-21

APD-21

4215B6 Vertical Direct Mount Attachment to Wall FurringScale: 1/2"=1'-0"

Vertical Direct Mount WallInstallation

BPD-21

4215B6 Vertical Direct Mount Attachment to Wall Furring SectionScale: 3"=1'-0"

Note: Wall Mounted Panels aremade with 1-1/4" Wide Backers

Wall Furring to Alignwith Panel Backers

Fasteners12" to 24" O.C.by Others

Grille Backer/DowelModule Ready to

Install

Page 16: Product Detail Set Contents: Ceiling Backer/Dowel Grille

Furring by Installer

Structural Wallby Others

234"

Z-Clip

Z-Bar

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer

Grille Backer/DowelModule Ready toInstall

1/2" Wood Dowel

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215B7 Backer/Dowel Grille

PD-22

Note: Z-Clip Wall Mounting Panelsare made with 2-1/2" Wide Backers

Z-Clip/Z-BarAttachmentby Others

Grille Backer/DowelModule Ready toInstall

APD-22

4215B7 Horizontal Z-Clip/Z-Bar Mount Attachment to WallScale: 1/2"=1'-0"

Horizontal Z-Clip/Z-BarWall Installation

BPD-22

4215B7 Horizontal Z-Clip/Z-Bar Mount Attachment to Wall SectionScale: 3"=1'-0"

Page 17: Product Detail Set Contents: Ceiling Backer/Dowel Grille

Z-Clips byInstaller

Solid Wood FinishedFace & Sealed Ends.

1/2" Backer

Grille Backer/DowelModule Ready to Install

234"

Furring by Installer

Structural Wallby Others

Z-Clips & Z-Barby Installer

1/2" Wood Dowel

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215B7 Backer/Dowel Grille

PD-23

APD-23

4215B7 Vertical Direct Mount Attachment to Wall FurringScale: 1/2"=1'-0"

Vertical Direct Mount WallInstallation

BPD-23

4215B7 Vertical Direct Mount Attachment to Wall Furring SectionScale: 3"=1'-0"

Grille Backer/DowelModule Ready to

Install

Note: Z-Clip Wall Mounting Panelsare made with 2-1/2" Wide Backers

Z-Clip/Z-BarAttachmentby Others

Page 18: Product Detail Set Contents: Ceiling Backer/Dowel Grille

REPRESENTATIVE

CUSTOMER

SHEET TITLE

SHEET NO.

PROJECT TITLE

PRODUCT

DRWNDATE CHECK

PROJECT LOCATION

SHEET REFERENCE

06/28/21 A.D. D.T.

ARCHITECT

Only the products that are identified assuch on this document are FSC® certified

Cer

tain

Teed

Cei

ling

Cor

pora

tion

20 M

oore

s Roa

dM

alve

rn, P

A 1

9355

800-

233-

8990

Certificate Code:

SCS-COC-006960

R

FSC

The mark ofresponsible forestry

FSC C151918R

DA

TERE

VIS

ION

S#

These drawings show typical conditions for installing the CertainTeed product shown. They should not be construed as a substitute for an architectural or engineering design and do not reflect the unique requirements of local codes, laws, statutes or regulations that may be applicable for a specific installation. CertainTeed assumes no liability forthe accuracy or completeness of the drawings for a specific installation or the fitness of the drawings for a particular purpose. The user is advised to consult with local licensed design professionals in order to assure compliance with all legal requirements. CertainTeed is not licensed to provide professional engineering or architectural services.

THIS DRAWING IS THE SOLE PROPERTY OF CERTAINTEED AND CONTAINS CONFIDENTIAL INFORMATION AND IS TO BE USED ONLY UNDER THE EXPRESS AUTHORITY GIVEN, IN WRITING, BY CERTAINTEED. ANY USE, REPRODUCTION, DISTRIBUTION IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF CERTAINTEED IS PROHIBITED.

Ceiling Backer/Dowel Grille

4215BD Backer/Dowel Grille

PD-24

CISCA Tolerances,Product Notes, andOrdering Notes

Installation Notes:

• Wood is a natural material with varying grain and colorcharacteristics, making each installation uniquely beautiful.Characteristics may vary from panel to panel. If desired, for greatervisual consistency, the products should be laid out and arranged inadvance of installation to achieve the desired effect. All productsshould be reviewed before installation to avoid undesirable visualpattern because of natural color and grain variations.

• Wood panels must be acclimatized for 72 hours prior to installation.Maintain relative humidity between 25%and 55% and temperaturebetween 50°F and 86°F (10°C and 30°C) for the life of the product,unless otherwise noted in order, quote, and submittal documents.

• Fixtures and MEP devices to be hung independently from ceilingsupport system. Fixtures and MEP devices may include but are notlimited to: light fixtures, HVAC diffusers, sprinkler heads and/or piping,speakers, security cameras, components, décor, etc.

• Reflected ceiling drawings will include penetrations of limited lightfixtures and HVAC registers only when the size of the wood is impacted.Other penetrations, including but not limited to sprinklers, securitycameras audio-visual, etc., Are typically not included in the drawing setas placement and code requirements vary by product and jurisdiction.5. Fixtures and MEP devices shown are for reference only; unlessotherwise noted all fixtures and MEP devices by others.

• Contractor to follow CISCA guidelines for suspension systeminstallation. Wood ceilings are typically heavier than other ceilingproducts. Follow manufacturer load requirements and installationspecifications based on the weights and dimensions of product beinginstalled.• All field cut products must be sealed with a clear sealer or stainedthen sealed.• See Product Detail Sets for edge condition details.

Suspension System Components and Accessories:

• CertainTeed 15/16" & 9/16"HD acoustical suspension systems soldseparately. Visit www.certainteed.com/suspension-systems/ for moreinformation and purchasing options.

Ordering Notes:

• All dimensions are shown for reference and willhave to be modified for field installation.

• Dimensions are to be field verified prior tofabrication. Changes in dimensions may result inquantity adjustments.

• Closet stock and spares are not included andmust be added to quantity shown if needed.

• Utilize the use of cut-offs where appropriate -product quantities based on partial productsbeing used.

Ordering Notes:All dimensions are shown for reference and willhave to be modified for field installation.Dimensions are to be field verified prior tofabrication. Changes in dimensions may resultin quantity adjustments. Closet stock andspares are not included and must be added toquantity shown if needed. Utilize the use ofcut-offs where appropriate - product quantitiesbased on partial products being used.

Suspension System Components and Accessories:CertainTeed 15/16" & 9/16"HD acousticalsuspension systems sold separately. Visitwww.certainteed.com/suspension-systems/ formore information and purchasing options.

Seismic Notes:For installations in seismic design categories D, E, or F the maximumsystem weight for acoustical suspension systems is 2.5 lbs. per squarefoot. ICC-ES ESRs, like CertainTeed Architectural ICC-ES ESR-3336, areavailable covering installations in seismic design categories D, E, & F anddefine installations including seismic installations for system weights up to4.0 lbs. per square foot. These are the maximum allowable weightsregardless of hanger wire placement without special engineeringapproved by local code jurisdiction officials. Seismic design category Cinstallations > 2.5 lbs. per square foot must follow installation requirementsfor seismic design categories D, E, & F. CertainTeed does not supplyacoustical suspension system details or layouts for systems exceeding 4.0lbs. per square foot.

Linear Wood - Rectangular boards oriented horizontally.

Board Length: ± 1/16” (0.062") Blade Width: ± 1/16” (0.062")

Board Thickness ± 1/32" (0.031")

Linear Reveal Width (D) ≤ 1/16" (0.062")

Bowing (Upward)(F) ≤ 1/32" per LF

Crook (Deviation)(A) ≤ 1/32" per LF

Cupping ≤ 1/32" (0.031") per LF

Board end squareness ± 0.5°

(D)=Factory Assembled Panels (F)= Per 6" high blade (A)=Supported on 24" centers