Prime Open-MRI
MR Sales & Marketing
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 1
A Different Solution for High-field Applications
The prime imaging capabilities
Superb image quality
Advanced capabilities
Sophisticated operability
Smooth operation on the large screen
Simple and quick protocol settings
The prime magnet technologies
Ultra high performance magnetic circuit
Advanced magnetic field control
Sophisticated Open MRI technologies
Sophisticated open architecture
Amenity in MRI examinations
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 2
0.4T Magnet – compact but strong
The 0.4T magnet of APERTO Lucent is supported
by technologies to achieve high efficiency of using
magnetic power.
High performance magnetic circuit (structure)
New generation material
Benefit:
Mitigation of eddy current which causes artifacts
Ultra High Performance Magnetic Circuit
Eddy current suppressive magnet
Fracture of scaphoid bone
FatSat T2WI T2WI
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 3
Stroke
T2WI
DWI
FLAIR
ADC
APERTO Lucent - Quality images with ECC
ECC System
Hitachi has solved eddy current problems by adopting the eddy current suppressed magnetic system and the ECC technology which predicts and suppresses the eddy current.
Benefit:
Quality images even with sequences susceptible to eddy current such as EPI-DWI and BASG
ECC:off ECC:on
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 4
Powered by latest gradient system
The most powerful gradient among
permanent magnet Open MRI
Gradient strength : 25mT/m
Slew rate : 55T/m/s The water cooling system is not required.
Significant time reduction
Shortened
rise-time
Enhancement of
the Gradient
system
APERTO
Lucent
Conventional
GC system
Gradient System
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 5
Super Shim* enables high order shimming to
compensate complex cause of inhomogeneity of
the magnetic field.
Performance of advanced sequences such as EPI-
DWI, BASG and CHESS (RF FatSat) is
dramatically improved.
Super Shim System
Y
X
Z Z
Y
X
Conventional (first order) shim High order shim
[Experiment of SuperShim with a phantom]
Off
On
[Improvement in BASGS with SuperShim]
Off On
Comparison of SuperShim On and Off
*Option
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 6
Vertical Field Technologies
[Head imaging with a joint coil]
Homogenous images with high
sensitivity are obtained with a
simple joint coil.
High sensitivity solenoid receiver coils
APERTO Lucent, a Vertical field Open MRI adopts high sensitivity solenoid receiver coils.
With the solenoid coils, the imaging area is positioned in the center of the receiver coil, and MR signals
are efficiently received so as to acquire high SNR images.
More over, sensitivity distribution of solenoid coils is wide in head-foot direction.
FLAIR T2WI
Solenoid type receiver coil
Receiving
direction
York
Magnetic field direction Permanent magnet
Solenoid type receiver coil signal intensity distribution
Pole piece
Sensitivity
Low High
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 7
Solenoid Receiver Coils
APERTO Lucent adopts high sensitivity solenoid receiver coils, which efficiently collect the minimal MR signals.
The receiver coils used for a variety of body parts are available.
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 8
A Different Solution for High-field Applications
The prime imaging capabilities
Superb image quality
Advanced capabilities
Sophisticated operability
Smooth operation on the large screen
Simple and quick protocol settings
The prime magnet technologies
Ultra high performance magnetic circuit
Advanced magnetic field control
Sophisticated Open MRI technologies
Sophisticated open architecture
Amenity in MRI examinations
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 9
RADAR (Radial Acquisition Regime)
Fills the K-space
with the center of the
k-space as the axis
Fills the k-space in one
direction with equally
spaced intervals
Principle of RADAR
kx
ky
Hybrid Radial Scanning
kx
ky
Normal Cartesian
Scanning
kx
ky
Radial Scanning
RADAR
Selectable from Radial and Hybrid radial methods
Now RADAR* is available for APERTO Lucent.
*Option
Filled the K-space with
blades (groups of trajectories
aligned parallel) determined
by echo factor
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 10
Advantages of RADAR
Features of RADAR Suppression of various “motion” artifacts
Body motion Respiration Heart beat
Fast and simple
Versatility in regions and slice planes
Various contrasts
Advantages of RADAR
Not only T2WI, but also T1WI, FLAIR and PDWI
Arbitrarily slice planes including AX, SAG and COR
Minimum prolongation in scan time Simple and easy to switch RADAR / Normal
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 11
Features of RADAR
FSE(T2WI) 3:46
RADAR-FSE(T2WI) 3:58
Suppression of motion artifacts
RADAR suppresses motion artifacts Artifacts from involuntary motion such as blood flow and CSF are also compensated
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 12
Advantages of RADAR
RADAR T2WI(FSE)
4:13
RADAR FLAIR(FIR)
5:20
RADAR T1WI(SE)
6:05
Flexibility in application with various contrasts
Not only T2WI, but also possible to apply with T1WI, FLAIR etc. Just a short prolongation in imaging time compared with normal scanning
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 13
Advantages of RADAR
Superior versatility
Slice planes incl. AX, SAG, COR can be selected arbitrarily Simple and easy to switch RADAR / Normal scanning
Abdomen (Free Breath) RADAR-FLAIR(COR) 5:21
RADAR-PDWI 5:38
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 14
Superb image quality
prime FSE *
primeFSE optimizes the echo allocation and minimizes Inter Echo Time in FSE sequences.
These features help reduce artifact and acquire easy-to-diagnose images.
Also, the flexibility of parameters simplifies the parameter settings.
* Option
Hippocampus primFSE image
High resolution images
High resolution images with
2048*2048 image reconstruction
matrix.
2048×2048 reconstruction
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 15
FITT (Fine tune technology)
FITT compensates gap in signals between slabs. This feature enables improved image
quality in MRA by optimizing MTC pulse and RF pulse.
FITT realizes clear images of fine vessels without boundary artifact between slabs.
VR* (Volume Rendering)
VR* helps understand anteroposterior relations. Since this rendering process is done on the MRI console but not the 2nd workstation, examination can be conducted efficiently.
*Option
cerebral aneurysm
High definition MRA
MIP image VR image
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 16
Early rhumatism
Separate images of fat and water can
be obtained in a wide FOV.
Benefit:
Applicable to various applications without
limitation of FOV.
FatSep
FatSep T2*WI
The open gantry allows special patient
positioning (like above picture) which is
difficult with Closed MR is possible.
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 17
High order shimming
Super Shim* enables high order shimming
to compensate complex cause of
inhomogeneity of the magnetic field.
Benefit:
Homogenized magnetic field even with a
patient inside the gantry.
Y
X
Z Z
Y
X
Conventional
(first order) shim High order shim
CHESS:on CHESS:off
CHESS (RF fat saturation)
*
CHESS fat suppression method CHESS* was thought to be difficult to be
realized with Open-MRI. However, high
homogeneity is secured by Super Shim*
which enables CHESS*.
Benefit:
Fat suppression with various sequences
including FSE, FIR, BASG and DW-EPI. Effective FOV with CHESS = 200mm
*Option
*
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 18
also enables APERTO Lucent to perform CE-Perfusion*.
CE-Perfusion is an application to measure slight change of magnetic
field around peripheral vessels.
Benefit:
Help diagnose acute brain infarction
Comparison of diffusion – perfusion mismatching
Dynamic Image
R
L ①
②
③
④
CE Perfusion
*
*Option Time-Intensity Curve
0.8
0.9
1
0 10 20 30 40 50 60
Time[s]
Inte
nsit
y [
rati
o]
②
① ④
③
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 19
MTT
CBF
CBV
2
1 3
4
1
(2days after symptom started)
Time-Intensity
3
2
DWI
FLAIR TOF T1
CE Perfusion
Clinical application of CE Perfusion measurement
Dynamic Image
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 20
A Different Solution for High-field Applications
The prime imaging capabilities
Superb image quality
Advanced capabilities
Sophisticated operability
Smooth operation on the large screen
Simple and quick protocol settings
The prime magnet technologies
Ultra high performance magnetic circuit
Advanced magnetic field control
Sophisticated Open MRI technologies
Sophisticated open architecture
Amenity in MRI examinations
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 21
Smooth Operation on the large screen
Wide Display
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 22
Simple and quick protocol settings
User-friendly GUI
The operating system based on that of high-field MRI Echelon.
The operational environment compatible with high-field applications.
High Speed Image reconstruction
The powerful computer architecture
30 times faster image reconstruction
compared to that of our conventional open
MRI.
Benefit:
Complicated processing such as FatSep
and Volume Rendering can be done in a
short time.
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 23
Simple and quick protocol settings
Curved MPR Radial MPR
Radial MPR creates MPR images of radially positioned slice planes.
Multiple slice images are reconstructed at the same time with easy operation.
Benefit:
This function is useful for diagnosis of complicated structure such as knee joint.
MPR (arbitrary plane reconstruction from 3D data) is applicable to curved slice planes.
Benefit:
Since multiple curves can be reconstructed at once, this feature is useful for cases such as scoliosis.
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 24
Simple and quick protocol settings
Parameter guidance function
In case the parameters need to be
changed because of the limitations of
scanning condition, alternative
parameters are automatically offered
on the screen.
Reshuffle of protocols
Protocols can be changed easily
according to patient’s condition.
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 25
A Different Solution for High-field Applications
The prime imaging capabilities
Superb image quality
Advanced capabilities
Sophisticated operability
Smooth operation on the large screen
Simple and quick protocol settings
The prime magnet technologies
Ultra high performance magnetic circuit
Advanced magnetic field control
Sophisticated Open MRI technologies
Sophisticated open architecture
Amenity in MRI examinations
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 26
Benefit:
Positioning of regions away from the midline such
as the shoulder and knee is easy and comfortable.
This feature helps acquire very clear images.
Open architecture The open design (320°open around the gantry) realizes patient comfort.
Benefit: Allows claustrophobic patients and small children to feel comfortable during the exam.
Comfortable patients yield to support to acquire best images.
Sophisticated open architecture
Lateral Slide Table
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 27
Soft Sound feature
→ ←
Gradient coils
Excellent patient experience in MR exam
• Quieter acoustic noise
• Small gradient vibration
Secrets of less audible noise and vibration feature
No resonant parts to amplify acoustic noise
The Flat GC does not vibrate much due to its shape
→ In case of APERTO Lucent, the gradient
vibration hit the GC from the side. Thus, the
GC does not vibrate much.
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 28
Amenity of patient table
Minimum height
The minimum table height of about 450mm enables the elderly patients and small children to get on and off the table easily.
Foot switch
For vertical and horizontal movements
of the table
Benefit:
Hands of the operator remain free for
taking closer care of patients.
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 29
Economical and ecological
Small installation space
Since the equipment room is not necessary, the installation space can be used efficiently. Also, the small shield room helps save the cost for ancillary equipments.
Actual installation plan may vary depending
on the condition of the site.
Electrical power saving
Since the required power supply is only
10kVA and a large-scale cubicle is not
required, the monthly cost of electricity is
very reasonable.
No need to purchase expensive
periodic replacement parts and supplies.
Stable operation is assured with no
risk of quench.
Small running cost
Copyright © Hitachi Medical Corporation.2010. All rights reserved. 30
Hitachi Medical Corporation
Introducing APERTO Lucent
MR Sales and Marketing
2010/07/07
END