Pressure Calibrator
Inside >>
2
Kains India
3
4
7
10
9
Table top-low and High Pressure
Portable - Pressure Tester
Dead Weight Tester
Master Pressure Gauge
Vacuum Calibration System
3
Kains India
Table top-low and High Pressure
Pressure testers are a pressure generation unit to generate the required pressure for calibrating the
pressure instruments in comparison method. In this method generally pressure instruments are calibrated against a Master Instrument. Scope of reference calibration is to minimize the time required for calibrating a pressure instrument. Though as primary standard, Dead weight Testers are used for the calibration of electronic or mechanical pressure measuring instruments, it requires uploading and downloading of weights for every single increment and decrement, which require more time to calibrate an instrument. In reference calibration, changing of master is required only when the range of the test instrument is changing, thus provide faster productivity with reliability.
Oil ‘or’ water operated
User friendly design
Ideal for lab calibration
Zero leakage
Zero maintenance for five years
Can be used for burst pressure testing of components
Can be used for opening pressure testing of components
Features
Design Table top
MODEL
Sample ordering code 11-R1KPCAL-701
Model: KPCAL- 701
Portable - Pressure Tester
Pressure testers are a pressure generation unit to generate the required pressure for calibrating the
pressure instruments in comparison method. In this method generally pressure instruments are calibrated against a Master Instrument. Scope of reference calibration is to minimize the time required for calibrating a pressure instrument. Though as primary standard, Dead weight Testers are used for the calibration of electronic or mechanical pressure measuring instruments, it requires uploading and downloading of weights for every single increment and decrement, which require more time to calibrate an instrument. In reference calibration, changing of master is required only when the range of the test instrument is changing, thus provide faster productivity with reliability.
Model: KPCAL- 702
Oil ‘or’ water operated
User friendly design
Ideal for lab/ site calibration
Zero leakage
Zero maintenance for five years
Can be used for burst pressure testing of components
Can be used for opening pressure testing of components
Features
Design Portable
Pre. Range2Kg / fcm
0 ... 100
0 ... 200
0 ... 400
Code
R1
R2
R3
Priming Pump
MODEL
Sample ordering code 11-R1KPCAL-702
4
Kains India
Portable - Pressure Tester
Pressure testers are a pressure generation unit to generate the required pressure for calibrating the
pressure instruments in comparison method. In this method generally pressure instruments are calibrated against a Master Instrument. Scope of reference calibration is to minimize the time required for calibrating a pressure instrument. Though as primary standard, Dead weight Testers are used for the calibration of electronic or mechanical pressure measuring instruments, it requires uploading and downloading of weights for every single increment and decrement, which require more time to calibrate an instrument. In reference calibration, changing of master is required only when the range of the test instrument is changing, thus provide faster productivity with reliability.
Model: KPCAL- 703
Oil ‘or’ water operated
User friendly design
Ideal for lab/ site calibration
Zero leakage
Zero maintenance for five years
Can be used for burst pressure testing of components
Can be used for opening pressure testing of components
Features
Design Portable
Pre. Range2Kg / fcm
0 ... 100
0 ... 200
0 ... 400
Code
R1
R2
R3
Priming Pump
MODEL
Sample ordering code 11-R1KPCAL-703
5
Kains India
Handles X 4
Level adjusting screw X 4
Priming lock valve
Master instrument
Reservoir
Instrument under test
Relief valve
Priming valve
Base plate
Base plate
Mounting holes -M8 X 4
Handles X 4
Instrument under test
Master instrument
Lock valve
Reservoir
6
Kains India
KPCAL- 702 / KPCAL- 703
KPCAL- 702 / KPCAL- 703
Dead Weight Tester
7
Kains India
MODEL
Sample ordering code DE-11-AOKDCAL-701
Model: KDCAL 701
ead weight testers are designed for calibration of pressure instruments. As primary standards, dead weight Testers are used for the calibration of electronic or mechanical pressure measuring instruments. In this, D
generally pressure instruments are calibrated against 'calibrated weights'. Dead weight testers are a piston-cylinder type measuring device. Dead weight Testers work in accordance with the basic principle that P= F/A, where the pressure (P) acts on a known area of a sealed piston (A), generating a force (F). The force of this piston is then compared with the force applied by calibrated weights. Table Top Machines are engineered for a different working range up to1200kg, with single or duel piston type.
8
Kains India
Handles X 4 Level adjusting screw X 4
Priming lock valve
Calibrated weights
Reservoir
Instrument under test
Relief valve
Priming valve
Base plate
9
Kains India
Master Pressure Gauge
Vacuum master gauges are instrumented for the calibration of vacuum instruments in a comparison
.
These gauges can be easily connected to Kains vacuum calibration system.
method by generating an equal vacuum in the master and 'IUT'* with Kains Vacuum system and then by taking the reference reading of the Master IUT's accuracy is compared. If the IUT shows more error than that of permissible, the IUT has to be rectified.
Model
Sample ordering code RADGAOKMCAL-7-207
Model: KMCAL- 7
10
Kains India
VACUUM CALIBRATION SYSTEM
Vacuum Pumps
Model: KVP 07
Ordering code KVP 07-OS
MODEL
Sample ordering code KVCAL-801
Model: KVCAL
Instrument under test
Master Instrument
Vacuum inlet
Mounting holes X 4
Vacuum exhaust
Control valve X 2
Base plate
11
Kains India
Beverages
Ship Building
Cement
RefinerySteel Plant
Machine Tool Bio Tech
Petrochemical
Power Plant
Chemical Industry Pulp & Paper
Pharmaceutical
Some Major Sectors that Serves
Kains India12