Upload
dinhdang
View
223
Download
4
Embed Size (px)
Citation preview
precision liquid handling
y o u r q u a l i t y p a r t n e r w o r l d w i d e
Electronic micropipettes
Digital setting micropipettes
Positive displacement micropipettes
Repeater pipette
Microdispenser pipettes
Bottle top dispensers
Low profile dispensers
Laboratory syringes
Graduated pipette aids
Instrument stands
Pipette tips / consumables
Service Center
Digital reading micropipettes
precision liquid handling
y o u r q u a l i t y p a r t n e r w o r l d w i d e
Electronic micropipettes
Digital setting micropipettes
Positive displacement pipettes
Repeater pipette
Microdispenser pipettes
Low profile dispensers
Bottle-top dispensers
Laboratory syringes
Pipette controllers
Work stations
Pipette tips / consumables
Service center
Digital reading micropipettes
SOCOREX ISBA SA
Champ-Colomb 7, P.O. Box
1024 Ecublens/Lausanne
Switzerland
www.socorex.com
Tel: +41 (0)21 651 6000
Fax: +41 (0)21 651 6001
C.G
EN.E
– C
409
Your local distributor
Important information
Refer to package inserts for safetyprecautions, operating instructionsand warranty terms.
User must pay special attentionto possible hand fatigue during serial pipetting and its medicalconsequences such as repetitivestrain injuries (RSI).
Mind risks involved in handlinghazardous liquids with respect to personal, third party andenvironmental protection and safety.
Products and specifications are subjectto change without prior notice.
Copyright © 2009 by Socorex ISBA SA, Switzerland
PR
EC
ISIO
N L
IQU
ID H
AN
DL
ING
2
00
9-2
01
0
Dear Partner in science,
Welcome to Socorex – a world of expertise in precision liquid handling.
Having our catalogue in yourhands – and on your shelf – willmean a lot to you when it comes tochoosing the best liquid handlingproducts for your applications.These pages will guide you througha wide selection of innovative,ergonomic and safe instruments,engineered and designed withexcellence in mind for the mostdemanding scientists.
An early leader, Socorex was the first manufacturer to obtain the EN ISO 9001 certification inthis field, back in February 1991. This is only one of the many milestones having made total quality acompany tradition and a culturalway-of-life for our management and staff members all together.
Well trained, documented andequipped to provide professionaladvice and technical support, the reliable network of authoriseddistributors represents anotherSocorex key quality asset.
But the millions of Calibra® andAcura® pipettors and other famousSocorex instrument brands in usethroughout the world would meanlittle, be it for our ever-growingnumber of customers and theirproven satisfaction.
Thank you for your trust, we arecommitted to stay your qualitypartner in liquid handling.
Sylvain Christen, CEO
Brief history
Socorex Isba SA, often referred toas just Socorex, was first founded inthe late 1940s. Two youngwatchmakers had identified the needfor new types of quality syringes formedical applications. The productsrapidly met international success.
In search for synergies, the companymerged with another firm a fewyears later.
Renamed Socorex Isba S.A., the newentity moved to Lausanne on LakeGeneva in 1960.
Its growth, particulary in thelaboratory field, soon forced thecompany out of the city to itstoday’s larger, expandable facilityin Ecublens, home of the FederalInstitute of Technology (EPFL) andUniversity of Lausanne (UNIL).
Sylvain Christen, CEO
Laurence Louy-Drevici,Business Development
Natalie Frischknecht, Customer Service Coordinator
Jean-Pierre Uldry, Director of Engineering
Prisca Buchs,Customer Service
Thérèse Valenziano,Customer Service
Welcome to Socorex – a world of expertise in prec
www.socorex.com
38
ProceduresService levels Maintenance and control per ISO 8655
Standard
• • • • • • • •
• • • •
10 x 10 x
10 x 2)
10 x 10 x
10 x 10 x
10 x 2)
10 x 10 x
10 x
10 x 2)
10 x
10 x
10 x 2)
10 x
ISO 17025
10 x
10 x 2)
10 x
10 x
10 x
10 x 10 x
10 x 2)
10 x
4 x 1)
4 x 1) 10 x
10 x
10 x 2)
10 x
• • • •
• • • •
-
-
--
• • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • •
• •
• • •
•
•
• • • • •
• • • •
Classic Premium Advanced Ultra Ultra SCS
1) Five measurements below 50 μL 2) When applicable
Instrument registration
Gravimetric test beforemaintenance (“as found”)
Decontamination, disinfection,disassembling, cleaning
Instrument check-up
X-ring replacement as needed
Other faulty parts replacement as needed
Function and tightness check
Gravimetric test aftermaintenance per ISO 8655
Gravimetric test after maintenance per ISO 17025
Final check and visa
QC certificate before maintenance (“as found”)
QC certificate after calibration (“as left”)
Accredited certificate per ISO 17025
Min. vol.
Min. vol.
Mid. vol.
Mid. vol.
Max. vol.
Mid. vol.
Max. vol.
Min. vol.
Max. vol.
Classic SCS Premium SCS New instruments
Accredited calibration per ISO 17025
Accreditedcertificate
to beordered
withinstrument
Service programme
Standard serviceRepair, maintenance, control and calibration,
2x4 measurements, with QC certificate.
The cost-effective solutionfor any liquid handling instrument.
Classic serviceCleaning and maintenance,
control and calibration, 2x 10measurements, with detailed
QC certificate.
Recommended as routine check.
Classic SCS serviceSame as above, but withISO 17025 calibration and SCS accredited certificate.
Alternative routine check whendealing with ISO 17025
procedures, or whenmastering uncertainties
is required.Ultra SCS service
Same as above with ISO 17025 calibration and SCS accredited certificate.
Ultimate service when dealing with ISO 17025 for GLPenvironment demanding analytical results.
Premium SCS serviceSame as above, but with
ISO 17025 calibration andSCS accredited certificate.
A must for laboratories dealing with ISO 17025 procedures, or
when mastering uncertainties isrequired. Available for new
instruments as well.
Premium serviceCleaning and maintenance,control and calibration, 3x10
measurements, with detailed QC certificate.
An in-depth check, also including mid-range measurements.
A choice of service levels
Advanced serviceControl, 2x10 measurements, with
detailed certificate before maintenance (“as found”). Then cleaning, maintenance and calibration,
2x10 measurements, with detailed QC certificate.
Perfect for instruments used in GLP environments or for validation of critical analytical results.
Ultra serviceControl, 3x 10 measurements, with detailed certificate beforemaintenance (“as found”). Then cleaning, maintenance and
calibration, 3x10 measurements, with detailed QC certificate.
Ultimate service for GLP environment when analytical results are demanded.
Products & services
Today’s manufacturing programmeincludes a wide variety of highprecision instruments used for reliablymeasuring, dosing, transferring,dispensing and injecting liquids in a large number of applications.
Manual and electronic micropipettes,multichannel pipettors, repeaterpipettes, dispensers, pipettecontrollers and re-usable syringes,together with their accessories,constitute the heart of the programme.
Each precision instrument bears itsown serial number and passes a strictperformance control attested by anindividual QC certificate.
“One stop does it all” is the mottoof the Socorex Service Center,offering a global repair andcalibration programme. The choicesrange from basic maintenance to accredited calibrationsof all micropipettes and dispensers according to ISO 17025– whatever their brand.
Yves Lachavanne, Marketingand Sales Support Manager
Our customers
We are proud to include virtuallyall private, industrial, academicand government laboratories asour customers.
Those are involved in routineresearch and educational activitiesin fields as diverse as lifesciences – such as biotechnologyand molecular biology – medicine,chemistry, pharmacology,environment, agriculture, etc.
Scientists are served efficiently bythe dedicated network of Socorexdistributors. Selected amongst the best suppliers, they carry aninventory of our products andprovide technical support, repairand calibration services.
Find your closest Socorex partnerslisted on www.socorex.com
Quality achievements
Socorex’s dedication to precision andquality has been an all-time tradition.Our commitment to manufacturingthe most reliable instruments andoffering the best services wasformalised with the completion of theISO 9001 and ISO 13485 QualityManagement System certifications.
Product lines used in the In VitroDiagnostics fields conform tothe IVD 98/79 EEC directive formedical devices and are CEcertified accordingly.
The safety-sensitive CalibrexTM
and AcurexTM dispensers bear the TÜV GS tested and certified.
Socorex product lines are designed to operate under national andinternational standards such as ISO 8655, GLP, GMP and NCCLS.
Three-year warranty cover for allmanual pipettors.
Product range
Electronic micropipettes
Acura®electro
Digital reading micropipettes
Acura®manual
Digital setting micropipettes
Calibra®digital
Positive displacement pipettes
Acura®positive
Repeater pipette
StepperTM / EcostepTM
Microdispenser pipettes
Acura®manual
Bottle-top dispensers
CalibrexTM digital
Low-profile dispensers
AcurexTMcompact
Laboratory syringes
DosysTM
Work stations
Pipette controllers
ProfillerTM / ProfilletteTM
Pipette tips / consumables
Qualitips®
Service center
3
7
14
17
18
19
20
21
25
32
29
33
37Yves Liechti,Logistics Manager
Jean-Marc Ammann, Qualityand Regulatory Affairs Manager
Jean-Pierre Cattin,Production Manager
Stephanie Boegli,Service Center
Pascal Forestier, TechnicalSupport Manager
YEAR
WA R R A NTY
ision liquid handling
Susanne Henry, Marketingand Communication
Pascal Durand, Administrationand Finance Manager
electronic micropipettes
The Acura®electro models
925 micro, 935 macro, 955 multi
Product advantages
Optimised ergonomics, light weight Easy, intuitive, self-teaching programme Right or left display reading Swift-interchange battery pack Fast charge, long working autonomy Adjustable tip ejector* fitting most tips Electronic control unit fits other volumetric modules
* Socorex patented
Natural ergonomics
The Acura® electro offers shape,balance and working ergonomicsresembling those of a manualinstrument. But comfort is so greatlyimproved that pipetting and resultconsistency are just outstanding.
Unique “right or left”
display reading
User converts instantly displayedinformation for right or left sidereading. All necessary elements arevisible at a glance during programming,pipetting and calibration steps.
Variable working speed
Located on the front side, speedselector allows instant change evenduring the pipetting process. Inaddition, slow speed can be activatedat any time by gentle touch of start button.
Time efficient maintenance
Clever pipette construction limitsmaintenance to a minimum andrequires no tool for disassembling the volumetric modules.Whenever sterilisation isneeded, the volumetric modules can be autoclaved at 121°C / 250°F.
Tip ejection – easier than ever
Maximal efficiency is obtained witha large, ergonomically located ejectorbutton. The shaft height adjustmentsystem called JustipTM (4 mm span) –controlled by efficient click-stops –allows a wide selection of tips fora tight nozzle fit.
On multichannel models, bowed shapeof ejector head adds to effortless, easy sequential tip ejection.
The Acura®electro is making electronic pipetting simpler and saferthan ever. The instrument includes a microprocessor-controlledmotor and a rechargeable battery. An intuitive control softwareallows quick access to five working modes and many volumesto select from. One-year warranty.
121˚C
3
2 3 4 51
1
2
3 5
4
Long working autonomy
The NiMH battery pack is located in thepower handle. It can be removed andchanged in a second. New 4.8V tensionenables fast battery charging (< 1.5hours) and provides extended workingautonomy (> 3000 consecutivepipetting cycles). When unused, theAcura® electro automatically goes on energy saving stand-by.
Calibration
Control software provides for instant access to calibration menu.Adjustments are performed directlyon the instrument’s keyboard.Any inaccurate plunger movement isdetected by the microprocessor whichwarns user by an error message.
Pipette charging stand
Stand allows charging and storing up to three electronic pipettes or batterypacks simultaneously. Each position isfitted with a red/green charging LED.Supplied with every Acura® electroinitial package.
Battery charging rack
Space saving stand holds up to threebattery packs simultaneously. The ideal charging and storage accessoryfor spare batteries, which are then available at any time.
Interchangeable volumetric
modules
Whatever the original Acura® electroavailable in the lab, it will fit othervolumetric assemblies offeredseparately. This alone contributes to make electronic pipetting affordable to all budgets.Before first use of a new volumetricmodule, proceed to instrumentcalibration. Performance data is then permanently retained ininstrument’s memory.
Powerful intelligence
The “no gimmick” intuitive controlsoftware does not require any particular skills. Avoiding complicatedprogramming steps, there is only fewbuttons on the keyboard to give accessto the various modes within seconds.
4
www.socorex.com
Forward pipetting
Reverse pipetting
Step-wise pipetting
Dilution (up to 3 liquids)
Mixing
21
1
2
ENERGY STAR®
qualified powersupply for a betterenvironment
electronic micro and macropipettes
0.05 μL0.25 μL1.0 μL5.0 μL
0.05 mL0.05 mL
< ± 2.5%1)
< ± 2.5%2)
< ± 1.5%3)
< ± 1.5%4)
< ± 1.0%5)
< ± 0.8%6)
< ± 1.8%< ± 1.6%< ± 1.1%< ± 1.0%
< ± 0.9%< ± 0.7%
< 1.2%< 0.9%< 0.5%< 0.4%
< 0.5%< 0.3%
< ± 1.0%< ± 0.7%< ± 0.6%< ± 0.5%
< ± 0.7%< ± 0.5%
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. Performance measured at 1) 1μL 2) 5μL 3) 20μL 4) 100 μL 5) 0.5 mL 6) 1 mL
* Replace x by code for adequate plug type depending on user location: E = Europe, G = UK, U = USA-Japan, A = Australia-NZ
< 1.8%1)
< 1.5%2)
< 0.7%3)
< 0.5%4)
< 0.6%5)
< 0.4%6)
Ultra 10 μL200 μL200 μL1000 μL
5 mL10 mL
925.0010.48x925.0050.48x925.0200.48x925.1000.48x
935.05.48x935.10.48x
925.0010.48925.0050.48925.0200.48925.1000.48
935.05.48935.10.48
800.0010800.0050800.0200800.1000
800.5000800.10000
< 0.5%< 0.3%< 0.2%< 0.2%
< 0.3%< 0.2%
Volume Division Tip style Cat. No.Initial
package*
Cat. No. Pipettealone
Cat. No. Volumetric
moduleMid. vol. Max. volMin. vol.
Inaccuracy (E%)Mid. vol.Min. vol.
Imprecision (CV%) Max. vol
Acura® electro 925
Acura® electro 935
0.5 – 10 μL2.5 – 50 μL10 – 200 μL50 – 1000 μL
0.25 – 5 mL0.5 – 10 mL
Nozzle protection filter
The 935 macro models accommodatea filter protecting instrument againstliquid penetration and contamination.Located in the nozzle, it can beremoved and changed easily.
Pasteur pipette adapter
Optional adapter-nozzle allows fittingof Pasteur pipettes on 5 mL modelin addition to Polypropylene tips(order accessory separately).
Performance and ordering information – InstrumentsAcura® electro pipettes alone supplied with individual QC certificate, Qualitips® pipette tips samples and operating instructions.
5
Description
Nozzle protection filters for 5 mL modelNozzle protection filters for 10 mL modelPasteur pipette adapter-nozzle for 5 mL model
Packaging
250 / pk100 / pk1 / pk
Cat. No.
322.05322.10
1.835.633
925micro
0.5 – 10 μL2.5 – 50 μL10 – 200 μL
50 – 1000 μL
935macro
0.25 – 5 mL0.5 – 10 mL
Ordering information – Accessories for Acura® 935 models
See Qualitips® page 33
Initial package
Includes electronic pipette, QCcertificate and operating instructions,pipette charging stand, power supply,additional battery pack, Qualitips®pipette tips samples.Recommended when purchasing an Acura® electro for the first time.
The Acura®electro 925 / 935
Optimised ergonomics, light weight Easy, intuitive, self-teaching programme Right or left display reading Swift-interchange battery pack Fast charge, long working autonomy Adjustable tip ejector* fitting most tips Electronic control unit fits other volumetric modules
* Socorex patented
21
1
2
www.socorex.com
The Acura®electro 955
8- and 12-channel models up to 350 μL Optimised ergonomics, light weight Easy, intuitive, self-teaching programme Right or left display reading Swift-interchange battery pack Fast charge, long working autonomy Adjustable tip ejector* fitting most tips Electronic control unit fits other volumetric modules
* Socorex patented
0.5 – 10 μL2.5 – 50 μL20 – 350 μL
0.5 – 10 μL2.5 – 50 μL20 – 350 μL
8-channel
12-channel
0.05 μL0.25 μL5.0 μL
0.05 μL0.25 μL5.0 μL
< ± 3.5%1)
< ± 1.0%2)
< ± 1.0%3)
< ± 3.5%1)
< ± 1.0%2)
< ± 1.0%3)
< ± 1.5%< ± 0.8%< ± 0.8%
< ± 1.5%< ± 0.8%< ± 0.8%
< ± 2.5%< ± 0.9%< ± 0.9%
< ± 2.5%< ± 0.9%< ± 0.9%
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. Performance measured at 1) 1 μL 2) 5 μL 3) 40 μL
* Replace x by code for adequate plug type depending on user location: E = Europe, G = UK, U = USA-Japan, A = Australia-NZ
< 3.0%1)
< 1.0%2)
< 0.6%3)
< 3.0%1)
< 1.0%2)
< 0.6%3)
Ultra 10 μL200 μL350 μL
Ultra 10 μL200 μL350 μL
955.08.010.48x955.08.050.48x955.08.350.48x
955.12.010.48x955.12.050.48x955.12.350.48x
955.08.010.48955.08.050.48955.08.350.48
955.12.010.48955.12.050.48955.12.350.48
800.08.010800.08.050800.08.350
800.12.010800.12.050800.12.350
< 1.0%< 0.4%< 0.3%
< 1.0%< 0.4%< 0.3%
< 2.0%< 0.7%< 0.4%
< 2.0%< 0.7%< 0.4%
Volume Division Tip style Cat. No.Initial
package*
Cat. No. Pipette alone
Cat. No. Volumetric
moduleMid. vol. Max. volMin. vol.
Inaccuracy (E%)Mid. vol.Min. vol.
Imprecision (CV%) Max. vol
Optimal working position
In addition to ergonomic design andperfect hand fitting of the pipette,the multichannel volumetric modulesrevolve to allow selection of the bestworking position.
6
Initial package
Includes electronic pipette, QCcertificate and operating instructions,pipette charging stand, power supply,additional battery pack, Qualitips®pipette tips samples.Recommended when purchasing an Acura® electro for the first time.
955multi
0.5 – 10 μL2.5 – 50 μL 20 – 350 μL
Performance and ordering information – InstrumentsAcura® electro pipettes alone supplied with individual QC certificate, Qualitips® pipette tips samples and operating instructions.
Description
Charging stand, 3 positions, for pipettes or battery packsBattery charging rack, 3 positions, for power handles onlySpare 4.8V NiMH battery pack (power handle)Spare 4.8V NiMH battery pack (power handle)
Packaging
1 / pk1 / pk1 / pk2 / pk
Cat. No.
320.903.48320.912.48900.910.48900.912.48
Power supply, 100-240V, Europe style plugPower supply, 100-240V, UK style plugPower supply, 100-240V, USA-Japan style plugPower supply, 100-240V, Australia - NZ style plug
1 / pk1 / pk1 / pk1 / pk
900.901.48E900.901.48G900.901.48U900.901.48A
Description Packaging Cat. No.
Ordering information – Accessories for Acura® electro 925 / 935 / 955 models
electronic multichannel pipettes
1
1
825 models Weight 835 models Weight
0.1 – 2 μL0.5 – 10 μL1 – 10 μL2 – 20 μL5 – 50 μL
10 – 100 μL20 – 200 μL
100 – 1000 μL
88 gr88 gr88 gr88 gr90 gr92 gr90 gr95 gr
0.2 – 2 mL0.5 – 5 mL1 – 10 mL
110 gr115 gr130 gr
855 models Weight
8x 0.5 – 10 μL8x 5 – 50 μL
8x 20 – 200 μL8x 40 – 350 μL12x 0.5 – 10 μL12x 5 – 50 μL
12x 20 – 200 μL12x 40 – 350 μL
155 gr165 gr165 gr168 gr184 gr199 gr201 gr203 gr
8x 0.5 – 10 μL8x 5 – 50 μL
8x 20 – 200 μL8x 40 – 350 μL12x 0.5 – 10 μL12x 5 – 50 μL
12x 20 – 200 μL12x 40 – 350 μL
155 gr165 gr165 gr168 gr184 gr199 gr201 gr203 gr
0.2 – 2 mL0.5 – 5 mL1 – 10 mL
110 gr115 gr130 gr
The Acura®manual models
815 fixed, 825 micro, 835 macro, 855 multi
Product advantages
Excellence in ergonomics Light weight and softness in use Adjustable tip ejector* fitting most tips Swift-set user calibration system* Unsurpassed metrologic performance and stability Shock, UV-light and autoclaving resistance CE certified IVD 98/79 EEC
* Socorex patented
digital reading micropipettesAcura manual
Most comfortable pipetting
The Acura® manual fits everybody’shand with or without glove. Ergonomicshape, light weight and ultra-softplunger travel offer a pleasant pipetting feeling.
Tip ejection – easier than ever
Most ergonomically positioned, the large surface, soft padded ejectorbutton provides for low-pressureactivation. In addition to ease of tipejection, the shaft height adjustmentsystem called JustipTM – controlled byefficient click-stops – allows a wideselection of tips to tightly fit the nozzle.
Smart and reliable
volume adjustment
State-of-the-art micrometric volumesetting is performed smoothly andprecisely by turning push button. Finelymachined click-stops and free rotating capprevent any unwanted volume alteration.
Digital display always
visible at a glance
Located on the front of the instrument,the display window allows set volume tobe visible at all times during pipetting.A comforting reassurance for the user.
The Acura®manual are precision pipettes designed and builtwith the users in mind. They combine high-tech materials withexceptional, user-friendly ergonomics. Whether inresearch or routine applications, they bring muchmore than superior performance and make pipettingsafe and agreeable. Entirely autoclavable at121°C / 250°F. Three-year warranty.
7
Weight of Acura® manual models
YEAR
WA R R A NTY
542 31
4
1
5
2 3
8
www.socorex.com
Instant calibration
The swift-set user calibration system –with integrated key and lockingmechanism – makes tedious proceduresa thing of the past. Easy and precise,it is in full compliance with internationalstandards and recommendations.
Protective calibrationseal sticker
Minimum maintenance /
sterilisation
Maintenance requirements are reducedto a minimum. Thorough cleaningand sterilisation can be achieved byautoclaving instruments fullyassembled (121°C / 250°F).
Colour coding at will
The Acura® pipettes have colour-codeddisplay windows and smarties button capssuggesting a selection of suitable tips.Are other colour combinations desirablefor individual, lab or departmentidentification? Then choose among14 colours of smarties, or pick the smartiemix which contains all colours.See page 12.
Shelf pipette holder 332
Fitting two micro, macro and/ormultichannel pipettes, it accommodates
all Acura® and Calibra® instruments.
See page 32.
Work station 337
Stable, sturdy universal pipette work stationfor 7 micropipettes of most brands. Availablein five attractive colours.
See more details page 32.
Work station 340
Convenient work station for 3 Calibra®or Acura®, multi- or single-channel pipettes.
See page 32.
1 2 3
Socorexcalibration
seal
1 2 3
adjustable micro and macropipettesAcura manual
Triopack
Ready-to-use set including three adjustablepipettes. See page 12.
Nozzle protection filter
The 835 models accommodate nozzlefilters for added protection against liquid filland contamination. See page 36.
Pasteur pipette adapter
Adapter nozzle allow fitting of Pasteurpipette on Acura® manual 2 and 5 mLmodels in addition to Polypropylene tips.The adapters have two O-rings guaranteeingproper holding and tightness of standard 2 mL Pasteur pipettes (Ø 7 mm). See page 36.
9
825micro
0.1 – 2 μL0.5 – 10 μL
1 – 10 μL2 – 20 μL5 – 50 μL
10 – 100 μL20 – 200 μL
100 – 1000 μL
835macro
0.2 - 2 mL0.5 – 5 mL1 – 10 mL
YEAR
WA R R A NTY
The Acura®manual 825 / 835
Smart and reliable volume adjustmentand very fine volume resolution
Single-handed volume setting Precision digital display visible at all times Click-stops and rotating plunger cap
prevent unwanted volume alteration JustipTM adjustable tip ejector* fitting most tips Swift-set user calibration system* Colour coding
* Socorex patented
21
1
2
Mid. vol.Volume
Mid. vol. Max. vol. Min. vol.Tip style Cat. No.
Min. vol. Max. vol.Division
< 1.5%< 0.5%< 0.7%< 0.5%< 0.4%< 0.2%< 0.2%< 0.2%
< 0.2%< 0.2%< 0.3%< 0.3%< 0.2%
< 3.3%< 1.2%< 1.6%< 1.1%< 0.7%< 0.6%< 0.4%< 0.4%
< 0.3%< 0.3%< 0.5%< 0.5%< 0.3%
< 5.0%1)
< 1.8%2)
< 2.5%< 1.7%< 1.0%< 1.0%< 0.6%< 0.5%
< 0.5%< 0.5%< 0.6%< 0.6%< 0.5%
< 2.0%< 1.0%< 1.0%< 1.0%< 1.0%< 0.8%< 0.6%< 0.5%
< ± 0.5%< ± 0.5%< ± 0.6%< ± 0.6%< ± 0.5%
< ± 6.0%1)
< ± 2.5%2)
< ± 2.5%< ± 2.5%< ± 1.5%< ± 1.5%< ± 1.5%< ± 1.5%
< ± 1.5%< ± 1.5%< ± 1.5%< ± 1.5%< ± 1.5%
< ± 4.0%< ± 1.8%< ± 1.8%< ± 1.8%< ± 1.3%< ± 1.2%< ± 1.1%< ± 1.0%
< ± 1.0%< ± 1.0%< ± 1.1%< ± 1.1%< ± 0.7%
0.1 – 2 μL 0.5 – 10 μL1 – 10 μL 2 – 20 μL5 – 50 μL
10 – 100 μL20 – 200 μL
100 – 1000 μL
0.2 – 2 mL0.2 – 2 mL0.5 – 5 mL0.5 – 5 mL1 – 10 mL
825.0002825.0010825.0010Y825.0020825.0050825.0100825.0200825.1000
835.02835.02PP 3)
835.05835.05PP 3)
835.10
Ultra 10 μLUltra 10 μL
200 μL200 μL200 μL200 μL200 μL1000 μL
2 mL2 mL / Pasteur
5 mL5 mL / Pasteur
10 mL
0.002 μL0.01 μL0.01 μL0.02 μL0.1 μL0.1 μL0.2 μL1 μL
0.002 mL0.002 mL0.01 mL0.01 mL0.01 mL
Inaccuracy (E%) Imprecision (CV%)
Acura® manual 825
Acura® manual 835
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.1) measured at 0.5 μL 2) measured at 1 μL 3) Model includes Pasteur adapter nozzle
Performance and ordering information
Optimal working position
In addition to ergonomic design andperfect hand fitting of the pipette, themultichannel volumetric modulerevolves for added user comfort.
10
www.socorex.com
multichannel micropipettesAcura manual
Adjustable tip ejector
Position of tip ejector can be adjusted inno time within a 4 mm span to perfectlymatch to tip used. Bowed shape of ejectorhead guarantees effortless, easysequential tip ejection.
Mid. vol.Volume
Mid. vol. Max. vol. Min. vol.Tip style Cat. No.
Min. vol.
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.1) measured at 1 μL
Max. vol.Division
0.5 – 10 μL5 – 50 μL20 – 200 μL40 – 350 μL
0.5 – 10 μL5 – 50 μL20 – 200 μL40 – 350 μL
0.01 μL0.1 μL0.2 μL0.4 μL
0.01 μL0.1 μL0.2 μL0.4 μL
< ± 3.5%1)
< ± 1.0%< ± 0.9%< ± 1.0%
< ± 3.5%1)
< ± 1.0%< ± 0.9%< ± 1.0%
< ± 2.5%< ± 0.9%< ± 0.8%< ± 0.9%
< ± 2.5%< ± 0.9%< ± 0.8%< ± 0.9%
< ± 1.5% < ± 0.8%< ± 0.7%< ± 0.8%
< ± 1.5%< ± 0.8%< ± 0.7%< ± 0.8%
< 3.0%1)
< 1.0%< 0.6%< 0.6%
< 3.0%1)
< 1.0%< 0.6%< 0.6%
< 1.0%< 0.4%< 0.3%< 0.3%
< 1.0%< 0.4%< 0.3%< 0.3%
< 2.0%< 0.7%< 0.5%< 0.5%
< 2.0%< 0.7%< 0.5%< 0.5%
Ultra 10 μL200 μL200 μL350 μL
Ultra 10 μL200 μL200 μL350 μL
855.08.010855.08.050855.08.200855.08.350
855.12.010855.12.050855.12.200855.12.350
Inaccuracy (E%) Imprecision (CV%)
8-channel
12-channel
Work station 340
Convenient work station for 3 Calibra®or Acura®, multi- or single-channelpipettes. See page 32.
Multichannel reservoirs
Well adapted for multichannel pipettes,the reagent reservoirs offer variousshapes and volumes. See page 36.
Performance and ordering information
The Acura® manual 855
8- and 12-channel models up to 350 μL Light weight and perfect hand-fitting Precision digital display visible at all times JustipTM adjustable tip ejector* fitting most tips Swift-set user calibration system* 360° rotation of volumetric module
* Socorex patented
855multi
0.5 – 10 μL5 – 50 μL
20 – 200 μL40 – 350 μL
See Qualitips® page 33
YEAR
WA R R A NTY
2 31
1
2 3
The Acura®manual 815 / 835F
Slim ergonomic design and light weight Ultra-soft plunger activation JustipTM adjustable tip ejector* fitting most tips User calibration with integrated key Colour coding
* Socorex patented
Cat. No.Inaccuracy (E%)
Imprecision (CV%)
Tip styleVolume
1 μL5 μL10 μL10Y μL15 μL20 μL25 μL30 μL32 μL40 μL50 μL60 μL70 μL75 μL80 μL90 μL100 μL120 μL150 μL200 μL250 μL300 μL400 μL500 μL600 μL700 μL750 μL800 μL900 μL1000 μL
2 mL2.5 mL5 mL10 mL
Acura® manual 835F
Acura® manual 815
< ± 2.0%< ± 1.4%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.75%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.6%
< ± 0.8%< ± 0.8%< ± 0.7%< ± 0.5%
< 1.0%< 1.0%< 0.7%< 0.8%< 0.5%< 0.5%< 0.6%< 0.6%< 0.6%< 0.5%< 0.4%< 0.5%< 0.4%< 0.4%< 0.35%< 0.3%< 0.3%< 0.4%< 0.3%< 0.3%< 0.4%< 0.4%< 0.3%< 0.3%< 0.3%< 0.2%< 0.2%< 0.2%< 0.2%< 0.2%
< 0.5%< 0.5%< 0.3%< 0.2%
Ultra 10 μLUltra 10 μLUltra 10 μL
200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL200 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL1000 μL
2 mL5 mL5 mL10 mL
815.0001815.0005815.0010815.0010Y815.0015815.0020815.0025815.0030815.0032815.0040815.0050815.0060815.0070815.0075815.0080815.0090815.0100815.0120815.0150815.0200815.0250815.0300815.0400815.0500815.0600815.0700815.0750815.0800815.0900815.1000
835.F02835.F02.5835.F05835.F10
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Performance and orderinginformation
fixed volume pipettesAcura manual
Tip ejection – easier than ever
Most ergonomically positioned, the large surface, soft padded ejectorbutton provides for low-pressureactivation. In addition to ease of tipejection, the shaft height adjustmentsystem called JustipTM – controlled byefficient click-stops – allows a wideselection of tips to tightly fit the nozzle.
Colour coding at will
The Acura®manual pipettes havecolour-coded display windows andsmarties button caps suggesting aselection of suitable tips. Are othercolour combinations desirable forindividual, lab or departmentidentification? Then choose among 14colours of smarties, or pick the smartiemix which containsall colours. See page 12.
YEAR
WA R R A NTY
815 / 835Ffixed
1 μL to 10 mL
11
See Qualitips® page 33
2
3
4
4
1
1 2 3
Cat. No.ColourCat. No.Colour
WhiteGreyVanillaLemonYellowOrangeRed
1.825.7101.825.7151.825.7161.825.7121.825.7171.825.7181.825.714
Smartie mix
Assorted colours (14 / pk)
Smarties plunger caps
Alternative colour selection (6 / pk)RosePinkPurpleIce blueBlueMintGreen
1.825.7191.825.7201.825.7211.825.7221.825.7131.825.7231.825.711
1.825.700
Cat. No.PackagingDescription
For model 835,2 and 5 mLFor model 835,10 mL
Fits 2 single or multi channelFits 2 single or multi channel
Fits 3 single or multi channel
Replacement sealsReplacement seals
Nozzle protection filter
Shelf pipette holder 332
Work station model 340
Calibration seal stickers
322.05322.10
320.332320.332.4
320.340
1.825.0251.825.100
250 / pk100 / pk
1 / pk4 / pk
1 / pk
25 / pk100 / pk
Cat. No.PackagingDescription
Universal work station model 337
Fits 7 single-channel micropipettes of most brands320.337G320.337R320.337B320.337M320.337Y
1 / pk1 / pk1 / pk1 / pk1 / pk
Light greyPastel roseIce blueMint greenVanilla yellow
www.socorex.com
12
Ordering information – Accessories
Ready-to-use set includes three Acura®manual adjustable pipettes,Qualitips®samples, QC certificate and operating instructions.There are nine different Triopack available,each covering specific volumes. The full coveragestretches between 0.1 μL and 10 mL. Triopack bringsa major price / quality advantage matchingbudget constraints.
The Acura®manual Triopack
Three adjustable micropipettes Large choice of volumes Budget friendly
Triopack and accessoriesAcura manual
Pack Cat. No.Contents (Micro /macropipette models)
Pack Cat. No.Contents (Micro /macropipette models)
Pack Cat. No.Contents (Micro /macropipette models)
825.TRIO.C
825.TRIO.J
825.TRIO.M
C
J
M
2 µL(0.1 – 2)
2 µL (0.1 – 2)10Y µL(1 – 10)
10 µL(0.5 – 10)
20 µL(2 – 20)50 µL
(5 – 50)
50 µL(5 – 50)200 µL
(20 – 200)200 µL
(20 – 200)
825.TRIO.O
825.TRIO.P
825.TRIO.S
O
P
S
10 µL(0.5 – 10)10Y µL (1 – 10)20 µL
(2 – 20)
100 µL(10 – 100)
100 µL(10 – 100)200 µL
(20 – 200)
1000 µL(100 – 1000)
1000 µL(100 – 1000)
1000 µL(100 – 1000)
825.TRIO.T
825.TRIO.V
835.TRIO.Y
T
V
Y
50 µL(5 – 50)100 µL (10 – 100)1000 µL(100 – 1000)
200 µL(20 – 200)1000 µL
(100 – 1000)5 mL
(0.5 – 5)
1000 µL(100 – 1000)
5 mL(0.5– 5)10 mL(1 – 10)
Ordering information – Triopack
Accessories – 815 / 825 / 835 / 855
See Qualitips® page 33
2 3
4 5
521
3
4
1
1:10 dilution pipetteAcura manual
The Acura®manual 810
Product advantages
Two pre-calibrated fixed volumes – no setting required Smooth activation, excellent ergonomics Interchangeable PE nozzle protection filter JustipTM system for height adjustment of tip ejector Both volumes calibrated independently Easy maintenance, cleaning and disinfection Fully autoclavable 121°C / 250°F
Air displacement pipette with two pre-calibrated steps allowssubsequent pipetting of 1 and 0.1 mL of the same liquid.Metal nozzle fits long straw tips to aspirate from narrowor deep reservoirs (i.e. Stomacher®bags). Ideal alternativeto the graduated glass pipettes when performing serial1:10 dilutions in bacteriology. Three-year warranty.
Simple operation
Depress plunger button in full, thenrelease slowly to aspirate 1.1 mLDepress plunger button to firststop, thus dispensing 1 mLin Petri dishDepress plunger button to secondstop, thus dispensing residual0.1 mL in next Petri dish
No setting required
Two fixed volumes within oneplunger travel.
Innovative dual calibration
Both volumes of 1 mL and 0.1 mL can be calibrated independentlyfrom each other.
Volume Inaccuracy(E%)
Imprecision(CV%)
Cat. No.
810.1100< ± 0.5%< ± 2.0%
< 0.4%< 2.5%
10.1 mL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Performance and ordering
information – InstrumentDescription
Straw tips polypropylene, sterile (L: 190 mm, ø: 4 mm)
Packaging
20x25 / pk
Cat. No.
313.1100Nozzle protection filter, PE material 100 / pk 322.810Work station 340 for 3 pipettes, see page 32Shelf pipette holder 332 for 2 pipettes
1 / pk 320.3401 / pk 320.3324 / pk 320.332.4
Ordering information – Accessories
JustipTM ejector
Turn left or right to adjust ejector tostraw tip position on the nozzle.
Straw tips
First class polypropylene (L: 190 mm,Ø: 4 mm), specially designed fornarrow vials and Stomacher® bags.No blocking by particles in suspension.
8101 + 0.1 mL
1
2
3
1.1 mL 1.0 mL 0.1 mL
1 2 3
YEAR
WA R R A NTY
13
2 3 41
1
2
3
4
Highly reliable pipette line with instant volume adjustment.The combination of mechanical precision, comfort and easeof use in the same instrument makes the Calibra®digitalone of the smartest high-end micropipettes in the market.Three-year warranty.
www.socorex.com
The Calibra®digital models
822 micro, 832 macro, 852 multi
Product advantages
Winding-free instant volume adjustment Unsurpassed performance and calibration stability Robust, long-lasting construction Shock, heat, chemicals and UV light resistance Reliable user calibration Autoclavable at 121°C / 250°F fully assembled
digital setting micropipettesCalibra digital
14
Comfort and safety
Easy and glove friendly volume settingand tip ejection bring added comfort.No unwanted volume alteration ordetipping while working.
Instant volume setting
Major feature of the Calibra® line,the twin cam system is fitted withpre-calibrated steps providing fortrue digital volume entry and numericaldisplay. The dual incrementation allows fast volume setting withouttedious winding.
Key volume adjustment
Example: from 10 to 50 μL in half arevolution of the setting wheel placed inits normal position.
Fine-tuning adjustment
Example: from 50 to 55.5 μL in half arevolution of the setting wheel inpulled position.
Colour coding
Attractive coloured plates and ejectorbuttons for easy identification ofvolume range and tip style.
Easy in-lab calibration
The calibration screw is located underthe rubber pad. Engraved divisions helpcalibrate instrument quickly andprecisely. Calibration key suppliedwith the instrument.
YEAR
WA R R A NTY
1
1
2
3 5
6
4
2 3
4
5 6
The Calibra®digital 822 / 832
Winding-free, instant volume adjustment Long-term performance stability Robust, long-lasting construction Re-calibration easily performed by user Minimal maintenance requirements
Nozzle protection filter
Macro models accommodateinterchangeable nozzle filters for added protection against liquid fill and contamination. See page 36.
Mid. vol.Volume
Mid. vol. Max. vol. Min. vol.Tip style Cat. No.
Min. vol.Inaccuracy (E%) Imprecision (CV%)
Max. vol.Division
< 1.5%< 0.5%< 0.7%< 0.5%< 0.2%< 0.2%< 0.2%
< 0.2%< 0.15%
< 3.3%< 1.3%< 1.6%< 1.1%< 0.6%< 0.4%< 0.4%
< 0.3%< 0.3%
< 5.0%1)
< 2.0%< 2.5%< 1.7%< 1.0%< 0.6%< 0.5%
< 0.5%< 0.3%
< ± 2.0%< ± 1.0%< ± 1.0%< ± 1.0%< ± 0.8%< ± 0.6%< ± 0.5%
< ± 0.5%< ± 0.5%
< ± 6.0%1)
< ± 2.5%< ± 2.5%< ± 2.5%< ± 1.5%< ± 1.5%< ± 1.5%
< ± 1.5%< ± 1.5%
< ± 4.0%< ± 1.5%< ± 1.5%< ± 1.5%< ± 0.9%< ± 0.9%< ± 0.6%
< ± 1.0%< ± 1.0%
0.2 – 2 μL1 – 10 μL1 – 10 μL2 – 20 μL10 – 100 μL20 – 200 μL100 – 1000 μL
0.2 – 2 mL 1 – 10 mL
822.0002822.0010822.0010Y822.0020822.0100822.0200822.1000
832.02832.10
Ultra 10 μLUltra 10 μL
200 μL200 μL200 μL200 μL1000 μL
2 mL10 mL
0.1 μL0.05 μL0.05 μL0.1 μL0.5 μL1.0 μL5.0 μL
0.01 mL0.1 mL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.1) measured at 0.5 μL
Calibra® digital 822
Calibra® digital 832
Performance and ordering information
15
digital setting micro and macropipettesCalibra digital
Work station 337
Stable, sturdy universal pipettework station for 7 micropipettesof most brands. Available in fiveattractive colours. See page 32.
Thin shaft shape
Helps reach contents from microtubesand / or narrow containers. The Calibra®provides convenient accessinto those hard to reach places.
822micro
0.2 – 2 μL1 – 10 μL2 – 20 μL
10 – 100 μL20 – 200 μL
100 – 1000 μL
832macro
0.2 – 2 mL1 – 10 mL
Pasteur pipette adapter
PVDF adapter fits pipette nozzle to accommodate standard glass Pasteurpipettes. FPM O-rings care for effectivetightness. Included with each2 mL Calibra® model.
YEAR
WA R R A NTY
1
1
2
2
16
www.socorex.com
The Calibra®digital 852
Instant volume setting Long-term performance stability Lower assembly rotates 360° for
optimal working comfort Easy sequential tip ejection Calibration simple to perform by user
Work station 340
Convenient work station for 3 Calibra®orAcura®, multi- or single-channel pipettes.See page 32.
Multichannel reservoirs
Well adapted for multichannel pipettes,the reagent reservoirs come in variousshapes and volumes. See page 36.
360° rotation
In addition to ergonomic hand fitting, the pipette lower assembly revolvesfor added user comfort.
Sequential tip ejection
Special shape of ejector head guaranteeseffortless, sequential easy tip ejection.
VolumeMax. vol. Min. vol.
Cat. No.Min. vol. Max. vol.
Division
0.05 μL0.5 μL1.0 μL
0.5 μL1.0 μL
1 – 10 μL10 – 100 μL20 – 200 μL
10 – 100 μL20 – 200 μL
< ± 3.5%< ± 1.0%< ± 0.9%
< ± 1.0%< ± 0.9%
< ± 2.5%< ± 0.9%< ± 0.9%
< ± 0.9%< ± 0.9%
< ± 1.5%< ± 0.7%< ± 0.7%
< ± 0.7%< ± 0.7%
< 3.0%< 1.0%< 0.6%
< 1.0%< 0.6%
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
< 1.0%< 0.4%< 0.3%
< 0.4%< 0.3%
< 2.0%< 0.7%< 0.4%
< 0.7%< 0.4%
852.08.010852.08.100852.08.200
852.12.100852.12.200
Mid. vol.Mid. vol.Inaccuracy (E%) Imprecision (CV%)
8-channel
12-channel
Performance and ordering information
digital setting multichannel pipettesCalibra digital
YEAR
WA R R A NTY
852multi
1 – 10 μL10 – 100 μL20 – 200 μL
Alternative ejector head
Optional, thinner ejector head improvescompatibility with long neck tips.
See Qualitips® page 33
1
1 4
3
2
2 3 4
17
positive displacementmicropipettes
Acura positive
Pipettes with ETFE-tipped plunger provide for positivedisplacement of sample in a precision capillary tube.Optimal accuracy and reproducibility when pipettinghigh-density, viscous, foaming or volatile liquids.Five models cover a range from 1 to 200 μL.Three-year warranty.
The Acura®positive 841
Product advantages
Step-wise volume adjustment Interchangeable plunger and glass capillary Matching colour codes on pipette, plunger and capillary Stainless steel, ETFE-tipped plunger
Colour coding
Pipette, plunger tip and glass capillarybear colour coding for easy volumeidentification.
ETFE-tipped plunger
Chemically inert ETFE material offersexcellent resistance when coming indirect contact with liquids.
Pre-set volumes
Each pipette has five, easy-to-adjustpre-set volumes. Clear volumeindication on pipette barrel.
Min. vol.Volumes
Min. vol. Mid. vol. Max. vol. Max. vol.Cat. No.
< 2.5%< 1.0%< 0.8%< 0.6%< 0.3%
< 2.0%< 0.9%< 0.7%< 0.5%< 0.3%
< ± 2.0%< ± 0.8%< ± 0.7%< ± 0.7%< ± 0.7%
< ± 3.0%< ± 1.5%< ± 1.2%< ± 0.7%< ± 0.7%
< ± 2.3%< ± 1.2%< ± 1.0%< ± 0.7%< ± 0.7%
1-2-3-4-5 μL5-10-15-20-25 μL10-20-30-40-50 μL60-75-80-90-100 μL100-120-150-175-200 μL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Mid. vol.
841.005841.025841.050841.100841.200
< 1.2%< 0.6%< 0.4%< 0.3%< 0.3%
Inaccuracy (E%) Imprecision (CV%)
Colour code
White2x whiteGreenBlueRed
Packaging
200 / pk200 / pk200 / pk200 / pk100 / pk
Cat. No.
341.005341.025341.050341.100341.200
Spare glass capillaires
Colour code
SteelWhiteGreenBlueRed
Packaging
5 / pk5 / pk5 / pk5 / pk5 / pk
Cat. No.
342.005342.025342.050342.100342.200
Spare plungers
Work station
For two positive displacementpipettes (Cat. No. 320.333).
Performance and ordering information – Instruments
Ordering information – Accessories
8411 – 5 μL
5 – 25 μL10 – 50 μL
60 – 100 μL100 – 200 μL
YEAR
WA R R A NTY
1
1
2
3
2 3
18
www.socorex.com
repeater pipetteStepperTM
The StepperTM411
Product advantages
4-finger activation Setting knobs bear clear indication of volumes
and number of aliquots Three positive displacement syringes,
colour coded Self-locking mechanism
Clear setting indication
After inserting disposable syringe,select appropriate volume. Markings oninterchangeable selector buttonsallow direct reading of set volume andcorresponding number of aliquots.
Colour coding
EcostepTM syringe andselector button bearcolour coding toeliminate anysetting error.
Highly comfortable pipette intended for reliable repeatdispensing within 10 to 5000 μL. Unique trigger actionmechanism eliminates thumb fatigue. Selected materials offeroutstanding shock resistance. Compact shape greatly limitsinternal instrument contamination. Large selection among53 different volumes; up to 73 doses per filling. One-year warranty.
41110 – 5000 μL
7349362924201815141211109887776
No. ofaliquots
VolumeμL
VolumeμL
VolumeμL
101520253035404550556065707580859095100
5075100125150175200225250275300325350375400425450475500
50075010001250150017502000225025002750300032503500375040004250450047505000
Fingertip activation
User friendly 4-finger trigger actioneliminates thumb fatigue during repeatdosing. Automatic safety lock preventsfalse delivery when dosing is completed.
Description
StepperTM 411 incl. 3 colour coded selector buttons, adapter, EcostepTM syringe samplesReplacement adapter for red EcostepTM syringeStand for one Stepper
Packaging
1 / pk
5 / pk
1 / pk
411.5000
1.411.7
320.411
Cat. No.
Ordering information
Volume Syringecapacity
Performanceat
Inaccuracy(E%)
Imprecision(CV%)
Sterile Packaging Cat. No.
20 μL100 μL100 μL500 μL1000 μL5000 μL
< ± 1.2%< ± 1.0%< ± 1.0%< ± 0.5%< ± 0.8%< ± 0.5%
< 2.3%< 0.6%< 1.8%< 0.4%< 1.2%< 0.4%
noyesnoyesnoyes
100 / box100 x 1 / box
100 / box100 x 1 / box
100 / box100 x 1 / box
316.010316.010.9316.050
316.050.9316.500
316.500.9
0.75 mL
3.75 mL
37.5 mL
10 – 100 μL
50 – 500 μL
500 – 5000 μL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C.
Performance and ordering information – EcostepTMsyringesOnly three sizes cover full volume range from 10 to 5000 μL. PE/PP materials.Supplied non-sterile in bulk, or sterile, single wrapped.
STOP
1
1 2
2 3 4
4
3
The Acura®manual 865
Product advantages
Excellent ergonomics, soft plunger activation Large volume display Easy in-lab calibration No need for consumables Autoclavable fully assembled at 121°C / 250°F Versatile feeding through bottle, tubing or syringe
19
Description Packaging Cat. No.
1 / pk1 / pk1 / pk1 / pk
1 / pk1 / pk
1 / pk
1 / pk
1.861.6311.861.21T1.861.9251.861.720
1.861.E321.170.054
1.170.058
320.340
Reservoir*, 30 mL, PP, LuerReservoir*, 30 mL, PTFE, LuerVial holder*, LuerInlet valve cap*, female Luer(for syringe)PTFE delivery cannula*Manifold*, 4-channel, Luer Lock,stainless steelManifold*, 8-channel, Luer Lock,stainless steelWork station 340 for 3 pipettes
*Autoclavable
Ordering information – Accessories
self-refillingmicrodispenser pipette
Acura manual
Hand-held, self-refilling microdispenser intended forrepeat distribution of microliter volumes. Carefully selectedmaterials ensure durability and resistance to aggressive media.Instrument combines easy handling of a regular micropipettewith flexibility of a repeater pipette.There is no need for plastic tips or consumables,which may represent substantial savings.Three-year warranty.
Convenient dispensing
Reliable valve system ensures highperformance dispensing, dose afterdose. It revolves to allow selectionof the best working position.
Min. vol.Volume
Min. vol. Mid. vol. Max. vol.Division
Max. vol.Cat. No.
< 2.0%< 1.5%< 0.6%
< 1.4%< 1.0%< 0.4%
< ± 1.5%< ± 1.0%< ± 0.6%
< ± 5.0%< ± 2.5%< ± 1.5%
< ± 3.5%< ± 1.8%< ± 1.1%
5-50 μL20-200 μL100-1000 μL
0.1 μL0.2 μL1.0 μL
Mid. vol.
865.0050865.0200865.1000
< 0.4%< 0.3%< 0.2%
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Inaccuracy (E%) Imprecision (CV%)
Performance and ordering information – InstrumentsIncluding: 90 cm silicone tubing, SS blunt end cannula, female Luer inlet valve cap,Q.C. certificate and operating instructions.
Swift-set calibration system*
Easy and precise system with integratedkey and locking mechanism, makingtedious procedures a thing of the past.
* Socorex patented
Protective calibrationseal sticker
Choice of feeding sources
Supplied with a 90 cm silicone tubing,the instrument also fits optional feedingsources: bottle, vial, syringe.
Great distribution flexibility
Outlet nozzle fits any Luer Lock needlesand cannulas. Optional PTFE cannulaprovides enhanced chemical resistance.Use 4- or 8-channel manifold whendispensing into microplates.
18655 – 50 μL
20 – 200 μL100 – 1000 μL
2
3
1 2 3
Needles & cannulas
see page 27
YEAR
WA R R A NTY
Excellent ergonomics
Instrument shape and lightweight offermost convenient pipetting comfort.Smooth plunger activation drasticallyreduces hand fatigue.
1
1
2 3 4
2 3 4
Socorexcalibration
seal
The AcurexTMcompact 501
Product advantages
Integrated dosing mechanism Simple, robust construction Retractable graduated column reduces instrument height Fluid path materials excluding any metal Choice of four reservoir sizes Fully autoclavable at 121°C / 250°F
20
www.socorex.com
Autoclavable extension tubing
PTFE Jet-PenTM and tubing helpdispense into vessels with maximumcomfort within a 60 cm distance.For 1- and 2-L reservoirs (Cat. No. 1.523).
low-profile dispensersAcurexTMcompact
Compact dispensers for safe reagent handling, adaptedto refrigerator storage as well as water bath heating.Dosing mechanism entirely protected inside reservoir.Manufactured and tested to fully comply with the latestregulations on instrument safety and precision, dispensersapproved for safety by the German TÜV organisation.Volumes range from 0.2 to 30 mL. One-year warranty.
Valve
BarrelPlungerReservoirDelivery jet and union
Pyrex glass and synthetic rubyNeutral glassPTFE-coated glassAmber glassPVDF / FEP / PFA
MaterialsParts
Volume Division
Min. vol. Mid. vol.
Imprecision (CV%)
Max. vol.
< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%
< 0.5%< 0.5%< 0.5%
< 0.5%1)
< 0.5%1)
< 0.5%1)
< 0.5%< 0.5%
< 0.5%2)
< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%
0.1 mL0.1 mL0.1 mL0.2 mL0.2 mL0.2 mL0.2 mL0.2 mL1.0 mL
Reservoircapacity
250 mL1000 mL2000 mL500 mL1000 mL2000 mL1000 mL2000 mL2000 mL
Cat. No.
501.02025501.021501.022501.0505501.051501.052501.101501.102501.302
0.2 – 2 mL0.2 – 2 mL0.2 – 2 mL0.4 – 5 mL0.4 – 5 mL0.4 – 5 mL1 – 10 mL1 – 10 mL1 – 30 mL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between20 and 25°C in accordance with ISO 8655. 1) measured at 0.5 mL 2) measured at 3 mL
Performance and ordering information
Space saving low profile
The graduated column is retractable forheight reduction, making the dispenserideal for storage in refrigerators.
Chemically inert materials
All parts in contact with the liquid aremade from chemically inert materials:
Glass reservoir
Amber glass offers optimal lightprotection.
5010.2 – 2 mL0.4 – 5 mL1 – 10 mL1 – 30 mL
Chemical compatibility
see page 24
1
1 2 3 4
2 3 4
bottle-top dispensersCalibrexTMdigital
The CalibrexTMdigital 520
Product advantages
Superior chemical resistance Long-lasting performance stability Simple construction – no tool for disassembling Instant volume setting In-lab calibration Autoclavable at 121°C / 250°F fully assembled
Designed for performance handling of liquids from a large varietyof bottles and flasks, the CalibrexTM dispensers combine the latestin dosing technology, high-tech materials and ergonomic design.Manufactured and tested to fully comply with current regulations,they are approved for safety by the German TÜV organisation.Three colour-coded 520 models with adjustable volumes areranging 0.25 – 2 mL, 1 – 5 mL and 1 – 10 mL. Fixed versions alsoavailable in any volume within these ranges. One-year warranty.
Friendly digital volume setting
Fast and precise volume adjustment.Efficient click-stop mechanism preventsunwanted alteration. Large display iseasy to read; the window adjusts todesired side of instrument body.Each step on the cylindrical cam ispre-calibrated and corresponds to onedivision on the volume adjustmentscale.
Optimised working position
The instrument rotates 360° foradequate positioning on top ofthe bottle.
Air filter
Air inlet can be enlarged to receivea membrane filter, if airbornecontamination is a concern.
Large selection of bottles, see page 24.
In-lab calibration
CalibrexTM dispensers are factorycalibrated and can be easilyrecalibrated by means of a dedicatedadjustment screw.
Easy maintenance
Disassembling / reassembling isfacilitated by the limited number of well connected parts – no tool needed.
Extension tubing, see page 23.
5200.25 – 2 mL
1 – 5 mL1 – 10 mL
21
Chemical compatibility
see page 24
1
1 2
3
4
5
6
2 3 4 5 6
www.socorex.com
22
The CalibrexTM digital 521
Product advantages
Superior chemical resistance Long-lasting performance stability Comfortable and convenient in use Solid, yet simple construction Instant volume setting In-lab calibration Autoclavable at 121°C / 250°F fully assembled
A true digital system
Cylindrical cam with pre-calibrated steps– one for each volume – contributes tothe long-term calibration stability.
Min vol.Volume Division
Min. vol. Mid. vol. Max. vol.
< 0.5%< 0.5%< 0.5%
< 0.5%< 0.5% < 0.5%
Mid. vol. Max. vol.
< 0.1%< 0.1%< 0.1%
< 0.1%< 0.1%< 0.1%
< ± 0.6%< ± 0.6%< ± 0.6%
< ± 0.6%< ± 0.6%< ± 0.6%
< ± 3.0%< ± 2.0%< ± 1.5%
< ± 1.5%< ± 1.5%< ± 1.5%
< ± 1.8%< ± 1.3%< ± 1.1%
< ± 1.1%< ± 1.1%< ± 1.1%
< 0.35%< 0.35%< 0.35%
< 0.35%< 0.35%< 0.35%
0.05 mL0.1 mL0.25 mL
0.1 mL1.0 mL1.0 mL
0.25 – 2 mL1 – 5 mL1 – 10 mL
2 – 20 mL10 – 50 mL10 – 100 mL
Cat. No.Adj.
volume
520.002520.005520.010
521.020521.050521.100
Cat. No.Fixed
volume*
520.F02520.F05520.F10
521.F020521.F050521.F100
Calibrex TM digital 521
Calibrex TM digital 520
Inaccuracy (E%) Imprecision (CV%)
In-lab calibration
The CalibrexTM dispensers are factorycalibrated. Recalibration easilyperformed by means of a dedicatedadjustment screw.
Easy maintenance
Disassembling / reassembling isfacilitated by the limited number of well connected parts – no tool needed.
Three 521 sizes expand the CalibrexTM line, dispensing volumesfrom 2 - 20 mL, 10 - 50 mL and 10 - 100 mL. Similar to the 520models in many respects such as construction quality, sturdiness,chemical resistance, smooth plunger travel, in-lab calibration,autoclaving, the 521 range has a distinct black design. Also fittedwith cylindrical cam and pre-calibrated steps, it includes anadditional fine-tuning ring. Fixed versions available in any volumewithin these ranges. One year warranty.
Performance and ordering information – CalibrexTM520 / 521Both CalibrexTM have a 32 mm base thread. They come with three adapters (520: 28,40, 45 mm, 521: 38, 40, 45 mm) and feed tube 300 mm (375 mm with 521.100).
5212 – 20 mL
10 – 50 mL10 – 100 mL
Special attention is paid to componentmaterials, providing for long instrumentlife. Parts coming in contact with theliquid flow are chemically inert.
Parts 521 models520 models
Feed tubeIntake valveValve ballsValve springBarrelBarrel plate / basePlungerOutlet valveBodyDelivery jet assembly
PTFE
Platinum-iridiumBorosilicate glass
Glass with PFA coatingCeramic
ETFEPTFE / ETFE
Borosilicate glassCeramic, ruby
CeramicPyrex glass
PTFE ETFE
* Specify desired fixed volume withininstrument range when ordering.
Performance values obtained with bidest. water atconstant temperature (± 0.5°C) comprised between20 and 25°C in accordance with ISO 8655.
Superior material selection
Chemical compatibility
see page 24
1
1
2
2
3
3
Bulk container aspiration
Work station facilitates liquid intakefrom drum or other remote container(< 10 m distance, < 2 m elevation).
Description
Work stationsStand for dispensers up to 50 mLStand for remote liquid intake, dispensers up to 50 mL*Stand for remote liquid intake, dispensers 100 mL*
Cat. No.
320.SB050320.BC050320.BC100
Packaging
1 / pk1 / pk1 / pk
* Dispenser and feed tube not included, to be ordered separately.
Extension tubing
Autoclavable PTFE delivery Jet-PenTM
and extension tubing help dispenseinto vessels with maximum comfortwithin a 60 cm distance. Fits CalibrexTM
520 / 521 dispensers up to 20 mL.
Feed tubing
Each CalibrexTM digital dispenser issupplied with one PTFE feed tubing.Spare feed tubings are available eithercut to the standard size, or uncutby the meter. The latter is alsorecommended when aspiratingfrom remote bulk containers.
Description
Extension and replacement PTFE tubings
Length
600 mm300 mm300 mm300 mm375 mmspecifyspecifyspecify
Extension tubing for dispensers up to 20 mLReplacement feed tubing, 520 all sizesReplacement feed tubing, 521, 20 mLReplacement feed tubing, 521, 50 mLReplacement feed tubing, 521, 100 mLFeed tube by the meter, uncut, 520: 2, 5 and 10 mLFeed tube by the meter, uncut, 521: 20 mLFeed tube by the meter, uncut, 521: 50 and 100 mL
Int. ø
2.2 mm5 mm
7.5 mm10 mm10 mm5 mm
7.5 mm10 mm
Cat. No.
1.524511.707521.621521.622521.623511.709521.705521.706
Ordering information
Dispenser stability
Stand holds dispenser up to 50 mL,when screwed on small-size bottles.
23
accessoriesCalibrexTMdigital
1
1 2
2
www.socorex.com
Type Ext. ø of bottle neck
Threaded, PP
Threaded, PTFETapered, PPTapered, PTFE
Cat. No.
GLP + ø
GLT + øNSP + øNST + ø
22, 25, 28, 30, 34,36, 38, 40, 45 mm36, 38, 40, 45 mm
18.8, 24, 29.2, 45 mm18.8, 24, 29.2 mm
Neck,ext. ø
Cat. No.
32 mm32 mm32 mm45 mm45 mm
45 mm
32 mm45 mm45 mm
45 mm45 mm45 mm45 mm
32 mm
25 mm25 mm32 mm45 mm
Volume
100 mL250 mL500 mL1000 mL2500 mL
2500 mL
500 mL1000 mL2500 mL
250 mL500 mL1000 mL2000 mL
500 mL
250 mL500 mL1000 mL2500 mL
SquareSquareSquareSquareRound
Round
SquareSquareRound
RoundRoundRoundRound
Round
SquareSquareSquareSquare
314.0100314.0250314.0500314.1000314.2500
314.2500H
314.0500PE314.1000PE314.2500PE
314.0250C314.0500C314.1000C314.2000C
314.0500P
315.0250315.0500315.1000315.2500
Shape
Amber glass
Amber glass, with handle
PE-coated Amber glass
Clear Borosilicate glass
Clear Pyrex glass, with connection neck
Polyethylene
24
Reagent bottles
Large selection of glass and Polyethylene reagent bottles, each supplied with one screw cap.Perfectly adapted with CalibrexTMbottle-top dispensers.Corresponding neck adapters supplied with the dispensers.
Bottle-neck adapters
Both 520 and 521 models have a32 mm base thread. They come alongwith three PP material bottle-neckadapters in 28, 40 and 45 mmdiameters (520) or 38, 40, 45 mmdiameters (521), bringing to four thenumber of suited bottle diameters.
Calibrex521520
Acurex501
B/1B/3AAAA
B/4A
C/2/4AAAAA
B/4C/3B/3B/3AAAAAAA
B/4
AA
B/4AAA
B/4A
B/2A
B/4AAA
B/4B/3B/3B/3AAAAA
B/4AA
AAAAAAAA
B/2AAAAAA
B/2/3B/2/3B/2/3
AAAAAAAA
Acetic acid 100%Acetic acid dilutedAcetoneAcetonitrileAscorbic acidBenzaldehydeBenzeneBoric acidBromineButanolButanoneCarbon disulfideChlorobenzeneChlorobutaneChloroformChloronitric acid 100%Chlorosulphuric acid 100%Chromic acid 100%Citric acidCyclohexaneCyclohexanoneDiethylene glycolDiethyletherDimethylformamide (DMF)Dimethylsulfoxide (DMSO)Dioxane / Diethylene dioxide
Reagents Calibrex521520
Acurex501
AB/4B/4AAAAAAA
B/3C/5AAAAAAA
B/2/4AAA
C/3AA
AB/4AAAAAAAAA
C/5AAAAAAA
B/2/4B/4AA
B/3AA
AAAAAAAAAA
B/2/3C/5AAAAAAAAAAA
B/2/3AA
EthanolEtherEthyl acetateEthylene glycolFormaldehyde (Formalin)Formic acidGazolineGlycerin < 40%HeptaneHexaneHydrochloric acid 37%Hydrofluoric acid 100% (HF)Hydrogen peroxideIodineIsopropanolLactic acidLiquid ammoniaMethanolMethylchlorideMethylen chloride (DCM)Methyl ethyl ketone MEKMethylmethacrylate (MMA)Mineral oilNitric acid 100%OctaneOil, veg. / anim. / min.
Reagents Calibrex521520
Acurex501
AA
B/3A
B/4B/4AAA
B/1AAAA
B/1A
B/2/3B/2/3B/4
B/2/4B/4B/4A
B/4B/4B/4
AA
B/3AAAAAA
B/1AAAA
B/1A
B/2/3B/2/3
AB/2/4B/4B/4A
B/4B/4B/4
AA
B/2/3AAAAA
B/1B/1AAA
B/1B/1A
B/2/3B/2/3
AB/2/4
AB/4A
B/4B/4A
Nitric acid dil. < 30%Oxalic acidPerchloric acid 100%Perchloric acid dilutedPetrol benzenePetroleum ether / spiritPhenolPhosphoric acid 100%Potassium chloridePotassium hydroxidePotassium permanganatePropionic acidSodium acetateSodium chloride / cooking salt Sodium hydroxideSodium hypochlorideSulfochromic acid 100%Sulfonitric acid 100%Terebentine oilTetrahydrofurane THFTolueneTrichlorethyleneTrichloroacetic acidTrichloroethane / methaneTrichloro trifluoro ethaneXylene
Reagents
Dispenser chemical resistance
A = Good resistanceB = Acceptable with limitationsC = Not recommended
1 = Possible crystallisation – blockage (do not let dry plunger / barrel together).2 = Swell of plunger protection layer, possible peeling.3 = Acid vapours (better resistance with lower concentration).
Do not leave instrument on bottle.4 = Risk of softening or discoloration of external parts through vapours.
Do not leave instrument on bottle.5 = Chemical degradation of glass parts (plunger / barrel).
Contact Socorex about other chemicals.
25
The DosysTMsyringes
Product advantages
Optimal hand balance and ergonomics Fast and reliable volume setting Excellent reproducibility Plunger tightness without O-ring High chemical resistance Fully autoclavable at 121°C / 250°F
laboratory syringesDosysTM
Simple, natural movements
Both pistol-grip and two-ring handles fit any hand in a comfortable way.Activation performed with limited effortfor efficient work even during longdispensing series.
Syringe stand
Stand holds syringe in ready-to-fetchposition. Easy-to-clean material.Autoclavable. (Cat. No. 320.170).
Volume selection – Reliable
reproducibility
Volume is set within seconds. It will not vary while activating the syringe,thanks to the safety-locking nut onthe micrometric screw. Dose-by-dose reproducibility (CV) is excellent,as witnessed by performance figures.
Plunger tightness without
O-ring
Smooth plunger travel and tightnessachieved through high-precisionstainless steel plunger and groundedglass barrel. No O-ring to mess with or replace.
Glass protection
Interchangeable glass barrel is protectedby a PVC sleeve (not autoclavable) toprevent breakage.
Few parts assembly –
Low maintenance
The automatic syringes are made of only six main parts, easy to disassemble.Fast access to all elements allows rapidand efficient cleaning. Spares are availableat reasonable cost.
From the basic unit to the corrosion-resistant model, the laboratorydedicated syringe line offers precision instruments you can trust.Intended for safe and reliable liquid distribution, the selectionof pistol-grip and two-ring instruments comes in a widevolume range. One-year warranty.
162163164
Two-ring handle
172173174Pistol-grip handle
1
1 2 5
3
4
6
3 4 5 62
Division Dosys 164Cat. No.
Dosys 174Cat. No.
174.0501174.0502174.0505174.0510
164.0501164.0502164.0505164.0510
0.05 mL0.1 mL0.5 mL1.0 mL
0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL
VolumeVolume Division Dosys 162Cat. No.
Dosys 172Cat. No.
172.0501172.0502172.0505172.0510
162.0501162.0502162.0505
0.05 mL0.1 mL0.5 mL1.0 mL
0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL
Division Dosys 163Cat. No.
Dosys 173Cat. No.
173.05003173.05005173.0501173.0502173.0505173.0510173.0520
163.05003163.05005163.0501163.0502163.0505163.0510
0.025 mL0.1 mL0.05 mL0.1 mL0.5 mL1 mL1 mL
0.025 – 0.3 mL0.1 – 0.5 mL0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL5 – 2 0 mL
Volume
www.socorex.com
DosysTMbasic syringes 162 / 172
Fill-by-fill (automatic) through needleor cannula
Supplied without valve system Luer Lock nozzle
Package includes syringe, PVC protectionsleeve and operating instructions.
Dose-by-dosedistribution
Dispensing distribution Sterile work Filtration at yournozzle tip
Aspiration with reversemodus valve
Animal injection
DosysTMclassic syringes 163 / 173
Self-refilling automatic Integrated valve system Luer Lock nozzle
Package includes syringe, one metersilicone feed tube, sinker, PVCprotection sleeve, aspiration and ventcannulas, set of spare for valve,operating instructions.
26
DosysTMpremiumsyringes 164 / 174
Self-refilling automatic Detachable valve system Enhanced corrosion resistance Luer Lock nozzle
Package includes syringe, one meter silicone feed tube, sinker, PVCprotection sleeve, aspiration, vent anddosing cannulas, set of spare for valve, operating instructions.
Parts
Feed tubingBarrelWasher, barrelPlungerValve systemWasher, valveSpring and balls, valveSinker, feed cannula
Basic / classic models
SiliconeBorrosilicate glass
FPMStainless steel DIN 304
Ni-Cr BrassPTFE
Stainless steel, DIN 304Ni-Cr Brass
Premium models
SiliconeBorrosilicate glass
FPMStainless steel DIN 316LStainless steel DIN 316L
PTFEStainless steel, DIN 304
Ni-Cr Brass
Liquid path materials (for chemical resistance)Performance all modelsVolume
Min. vol. Max. vol.< 0.5%< 0.4%< 0.4%< 0.4%< 0.2%< 0.2%< 0.4%
< 1.2%< 0.9%< 0.6%< 0.5%< 0.4%< 0.4%< 0.4%
< 1.8%1)
< 1.2%< 0.7%< 0.6%< 0.5%< 0.5%< 0.5%
0.025 – 0.3 mL0.1 – 0.5 mL0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL5 – 20 mLTests performed with bidest. water, using stainless steel cannula (1.2x50 mm), at constant working speed. 1) Measured at 0.075 mL
Imprecision (CV%)Mid. vol.
DosysTMlaboratory syringes – Unlimited applications
Instrument descriptions and ordering informationCorrosionresistantCorrosionresistant
27
accessoriesDosysTM
Multiple dispensing manifolds
For convenient distribution in 24- and96-well plates. Tight-fitting Luer andLuer Lock syringe nozzles. Stainlesssteel with PTFE stoppers, autoclavable.
Injection needles
Beveled, high-quality needles, stainlesssteel, autoclavable. 12 / pack.
Dispensing cannulasBlunt end superior cannulas, stainlesssteel, autoclavable.
Cleaning brushes
Heavy-duty nylon brushes with tufted endand plastic handle for barrel cleaning.
DrenchersFor safe animal mouth- and nose-feeding. Stainless steel, autoclavable.
Accessories for self-refilling syringes
Description
4-channel manifold8-channel manifold
Packaging
1 / pk1 / pk
Cat. No.
1.170.0541.170.058
ø x L, mm Cat. No.
371.0810371.0825371.0830371.0840371.1010371.1020371.1030371.1040371.1210371.1220371.1235371.1250371.1420
Additional sizes available
0.8 x 100.8 x 250.8 x 300.8 x 401.0 x 101.0 x 201.0 x 301.0 x 401.2 x 101.2 x 201.2 x 351.2 x 501.4 x 20
ø x L, mm Cat. No.
371.1435371.1620371.1625371.1630371.16100371.1810371.1820371.1830371.2030371.2040371.2050
1.4 x 351.6 x 201.6 x 251.6 x 301.6 x 1001.8 x 101.8 x 201.8 x 302.0 x 302.0 x 402.0 x 50
Size (ø x L) Packaging
12 / pk1 / pk1 / pk1 / pk1 / pk1 / pk1 / pk
Cat. No.
370.0840371.1210UN370.1250
371.1620UN371.2030UN370.22100370.22150
0.8 x 40 mm1.2 x 10 mm1.2 x 50 mm1.6 x 20 mm2.0 x 30 mm2.2 x 100 mm2.2 x 150 mm
Size (ø x L) Packaging
1 / pk1 / pk1 / pk1 / pk
1 / pk1 / pk1 / pk1 / pk
Cat. No.
376.0925S376.1251S376.16102S376.30203S
376.0925B376.1251B376.16102B376.30203B
0.9 x 25 mm1.2 x 51 mm1.6 x 102 mm3.0 x 203 mm
0.9 x 25 mm1.2 x 51 mm1.6 x 102 mm3.0 x 203 mm
Drenchers, straight
Drenchers, bent
Alternative feed sources
Optional vial holder conversion setand reagent reservoirs for additionalliquid feeding possibilities.
Description
Vial holder conversion set for 163 and 173 models (except 20 mL), without vialPP bottle, 60 mLPP bottle, 125 mLPP bottle, 250 mL
Packaging
1 / pk
1 / pk1 / pk1 / pk
Cat. No.
1.187.1C
1.187.060*1.187.150*1.187.250*
*Use with Rotlauf inlet valve (Cat. No. 187.613) only, to be ordered separately.
Enhanced tightness set
The special clear glass barrel / X-ringfitted plunger enhance tightness whendemanded by application(ex. filtration, aspiration, etc.)
Description
Set includes one each plunger, X-ring,5 mL barrel and greaseSpare barrel for tightness set, 5 mL
Packaging
1 / pk
6 / pk
Cat. No.
1.170.205
0187.05T
Aspiration valve
Reverse modus valve set for liquidaspiration (ex. waste collection inseparate container). Vented wastecollector cap and enhanced tightnessset recommended.
Description
Reverse modus aspiration valve unit for 164 / 174 modelsScrew cap ø 45 mm, with tubing connection and filtered air outlet
Packaging
1 / pk
1 / pk
Cat. No.
1.170.952
1.170.945
Description
For 0.3, 0.5, 1 mL barrelsFor 1, 2, 5 mL barrelsFor 5, 10, 20 mL barrelsSet of 6 nylon brushes, 2 each
Packaging
6 / pk6 / pk3 / pk6 / pk
Cat. No.
1.170.3011.170.3051.170.3201.170.300
1
1 2 3 4 5
6 7 8 9
2 3 4 5
6 7 8
9
www.socorex.com
155.0301
155.0305155.0310155.0320
3 / pk3 / pk3 / pk3 / pk2 / pk1 / pk
0.05 mL0.1 mL0.2 mL0.2 mL1 mL2 mL
0.1 – 1 mL0.5 – 2 mL0.2 – 5 mL1 – 10 mL1 – 20 mL1 – 50 mL
155.0501155.0502155.0505155.0510155.0520155.0550
Glass LuernozzleCat. No.
Volume Division Packaging Metal LuerLock nozzle
Cat. No.
28
Other spare parts
Refer to separate list for exhaustive selection.
Includes springs, balls, washer for valve and barrel washer.
Description Packaging Cat. No.
6 / pk6 / pk6 / pk6 / pk6 / pk6 / pk3 / pk
0187.0030187.0050187.010187.020187.050187.100187.20
Barrel, syringe 0.3 mLBarrel, syringe 0.5 mLBarrel, syringe 1 mLBarrel, syringe 2 mLBarrel, syringe 5 mLBarrel, syringe 10 mLBarrel, syringe 20 mL
Description Packaging Cat. No.
1 bag1 bag1 bag1 bag1 bag1 bag1 bag
1.187.720031.187.720051.187.72011.187.72021.187.72051.187.72101.187.7220
Kit for valve, syringe 0.3 mLKit for valve, syringe 0.5 mLKit for valve, syringe 1 mLKit for valve, syringe 2 mLKit for valve, syringe 5 mLKit for valve, syringe 10 mLKit for valve, syringe 20 mL
Description Packaging Cat. No.
6 / pk6 / pk6 / pk6 / pk6 / pk3 / pk
1.170.40051.170.4011.170.4021.170.4051.170.4101.170.420
Sleeve, 0.3, 0.5 mL barrelsSleeve, 1 mL barrelsSleeve, 2 mL barrelsSleeve, 5 mL barrelsSleeve, 10 mL barrelsSleeve, 20 mL barrels
Description Packaging Cat. No.
1 / pk
1 / pk
1 / pk
1 / pk
1 / pk
Short vent cannulas
Long feed cannulas
187.933
187.591
187.593
187.592
187.594
Plastic / SS, syringes 0.3 to 5mLChrome plated, syringe 10 mLChrome plated, syringe 20 mL
Chrome plated, syringes 0.3 to10 mLChrome plated, syringe 20 mL
Description Packaging Cat. No.
1 m / pk3x 1 m / pk10 m / pk
by the meter1 m / pk
187.705187.905187.910187.710187.707
Tube, syringes 0.3 to 10 mL, cutTube, syringes 0.3 to 10 mL, cutTube, syringes 0.3 to 10 mL, uncutTube, syringes 0.3 to 10 mL, cutTube, syringe 20 mL, cut
The DosysTMall-glass syringes
The reusable borosilicate glass syringes offer superiorchemical and heat-shock resistance. A precious,low-cost alternative to plastic syringes, complementingthe self-refilling models in many applications.
Product advantages
Precision-machined plunger and barrel Excellent fitting and tightness Permanent, high-visibility graduations Sterilisation up to 160°C / 320°F
Grounded glass barrels
Spare parts for self-refilling syringes
Spare bags Vent and feed cannulas
1551 to 50 mL
PVC protection sleeves Feed tubing (medical quality silicone)
160°C
spare parts and all-glass syringesDosysTM
Ordering information
1
1
2 4
3 5
2 3 4 5
electronic pipette controllerProfillerTMelectro
29
The ProfillerTM electro 446
Product advantages
Powerful pump – fills 25 mL in 3 seconds Simple, fast operation Comfortable finger triggers Low battery light NiMH battery rechargeable during use Interchangeable protection membrane filter Stand suitable for bench or wall mounting
Variable speed
Switch enables selection of fast or slow aspiration and dispensing(with blow-out). Fast speed filling upto 25 mL in under 3 seconds. Gravitydispense mode is designed for use with’To Deliver’ (TD) pipettes.
Ordering information – Instrument
Supplied with power supply, two sparehydrophobic filters (0.45μm and 0.2μm),bench / wall stand and instruction manual.
Battery charge
Instrument plug enables chargingbattery either in storage positionor during use.
Ordering information – Accessories
Finger triggers
Suction and dispensing are controlledthrough two ergonomically positionedfinger triggers. They provide a comfortablegrip with minimum activation effort.
Convenient stand
Suitable for bench or wall mounting,stand houses ProfillerTM electro withor without a pipette in place.
Pipette controller fitting any hand in a very comfortable way. Shapeis ideal for working with glass or plastic pipettes within laminarflow or microbiological safety cabinet. A powerful, yet quiet motorand a switch to set both aspiration and dispensing speeds enablemaximal working efficiency even with large pipetting volumes.One-year warranty.
Description Packaging Cat. No.
1 / pk1 / pk
1 / pk
1 / pk
1 / pk
1 / pk
320.446900.916
900.446A
900.446E
900.446G
900.446U
Spare standSpare 1.2V NiMH batteryPower supply, Australian New Zealand style plugPower supply, Europe style plugPower supply, UK style plugPower supply, USA-Japan style plug
Description Packaging Cat. No.
5 / pk5 / pk1 / pk3 / pk3 / pk
322.435322.4001.435.011.435.021.435.03
Membrane filter, 0.45μmMembrane filter, 0.2μmSilicone pipette holderNose cone – whiteAlternative nose conespink, violet, green (1 each)
ProfillerTM electro 446 Packaging Cat. No.
1 / pk1 / pk1 / pk
1 / pk
446.100E446.100G446.100U
446.100A
With Europe style plugWith UK style plugWith USA/Japan style plugWith Australia/New Zealand style plug
446Pipettes
up to 100 mL
1
1
2 3
2 3
www.socorex.com
manual pipette controllersProfillerTMmanual
30
Squeezable bulb
Simply squeeze large capacity silicone bulb for efficient aspiration. If additional aspiration is needed, it can be squeezed even duringpipetting. 436 model has a distinct flat-shaped bulb.
Precise control
Thumb lever button for left- and right-handed users to easily control bothaspiration and dispensing speeds.
Liquid blow-out
Press large button to expel residualliquid when using blow-out typepipettes.
Protection filter
Interchangeable hydrophobicmembrane filter guarantees effective protection against airbornecontamination during aspirationand dispensing.
Colour coding cones
Nose cone can be changed forindividual, laboratory or departmentidentification. Choose among regularwhite or a bunch of three colours.
Pipette holder
Conical shape of silicone pipette holdertightly fits graduated glass or plasticpipettes. Autoclavable.
The ProfillerTMmanual 435 / 436
Product advantages
Large capacity bulb Soft action lever button Efficient blow-out system PTFE protection membrane filter Maintenance free Alternative colour-coded nose cones
Robust and easy to use, both models offer ergonomic shape andlight weight. They provide smooth control in both aspirating anddispensing, using glass or plastic pipettes of volume up to 100 mL.One-year warranty.
435Pipettes
up to 100 mL
436Pipettesup to 100 mL
Ordering information – AccessoriesOrdering information – Instruments
Description Packaging Cat. No.
5 / pk5 / pk1 / pk3 / pk3 / pk
322.435322.4001.435.011.435.021.435.03
PTFE membrane filter, 0.45 μmPTFE membrane filter, 0.2 μmSpare silicone pipette holderRepl. nose cone – whiteAlternative nose cones – pink, violet, green (1 each)
Description Packaging Cat. No.
1 / pk
1 / pk
435.100
436.100
ProfillerTM 435,egg style grey bulbProfillerTM 436,flat shaped blue bulb
manual
manual
1
1 43 5
6
2
2 3 4 5 6
The ProfilletteTM 406
Product advantages
One-hand operation Easy filling and dispensing Air inlet valve for fast distribution Colour coding per size Maintenance free
31
Cat. No.
406.002406.010406.025406.300
Colours
bluegreenred
assorted
Packaging
1 / pk1 / pk1 / pk3 / pk
Volume
2 mL10 mL25 mL2 / 10 / 25 mL
Ordering information – Instruments Ordering information – Accessories
Description Packaging Cat. No.
1 / pk
1 / pk
1.406.01
1.406.02
Spare siliconepipette holderRepl. nose screw
4062 mL
10 mL25 mL
Low-cost, easy-to-use pipette fillers suitable for graduated glass andplastic pipettes. Rotate wheel to aspirate. Fast release by pressingair inlet valve button, or gradual release by gently turning wheel.
Assorted package includes one each size.
pipette fillersProfilletteTM
www.socorex.com
32
work stationspipette
Universality
One for all, the work station fits newand old generations of Socorex® andother brand pipettes.
Extended compatibility
Work station 340 also fits the Acura®810 dilution pipette and Acura®865microdispenser pipettes.
Colour Packaging Cat. No.
1 / pk1 / pk1 / pk1 / pk1 / pk
320.337G320.337R320.337B320.337M320.337Y
Light greyPastel roseIce blueMint greenVanilla yellow
Universal 7 pipette work station 337
Colour Packaging Cat. No.
1 / pk 320.340Light grey3 pipette work station 340
Colour Packaging Cat. No.
1 / pk4 / pk
320.332320.332.4
Transparent blueShelf pipette holder 332
Ordering information
Ordering information
Ordering information
7-position work station
Space-saving pipette stand holds up toseven single-channel pipettes of mostbrands. Made of sturdy polyamidmaterial, easy to clean. Anti-slippads guarantee bench stability.
Attractive pastel colours
Light grey
Pastel rose
Ice blue
Mint green
Vanilla yellow
3-position multi- and single-
channel pipette work station
Innovative design fits all Calibra®and Acura®models. Easy reach of eachinstrument. Heavy bottom plate andanti-slip pads guarantee high stability.Made of polyamid material.
Shelf pipette holder 332
for 2 instruments
Fitting two micro, macro and/ormultichannel pipettes, the attractivedesign accommodates all Acura® andCalibra® instruments. The self-adhesivestrip supplied ensures lastingattachment on any surface. Made of polycarbonate material.
340
332
337
1
1 2
2 4
4 5
5
3
3
33
pipette tipsQualitips
A perfect match between micropipettes and tips guaranteestrouble-free pipetting and reliable results. The Socorex Qualitips®are designed to fulfil above preconditions. The line is exclusivelymade from high grade, virgin, metal-free polypropylene. Precision injection moulding care for air-tight fit. Stringent quality procedures ensure lot by lot consistency.Various shapes in a range from 10 μL to 10 mL.
SizeCat. No.
70.9 mm
42.3 mm
31.0 mm
31.0 mm
302.0010GR
302.0020R
302.0020B
309.0010FR
309.0010R
309.0010B
45.6 mm302.0010FR302.0010AFB
Qualitips 10 μL
Qualitips 20 μL
Qualitips 100 μL
54.1 mm308.0100FR
69.0 mm308.0100GFR
SizeCat. No.Description
51.0 mm 308.0020FR
69.0 mm308.0020GFR
308.0020FS
SizeCat. No.Description
DescriptionFilterCapacityTip also fits Colour Style Unit Quantity
10 μL
10 μL
10 μL
10 μL
10 μL
10 μLBT, E, G
BT, E, G
Natural
Natural
Natural
Natural
Natural
Natural
No
No
No
Yes
No
No
No
No
No
Yes
No
No
Rack
Rack
Bag
Rack
Rack
Bag
4 x 204
10 x 96
1000
10 x 96
10 x 96
1000
Gel loading
Micro
10 μL10 μL
B, E, F
B, BT, E, G
B, BT, E, G
B, BT, E, F, G
B, E, G, FB, E, G, F
NaturalNatural
YesYes
YesNo
RackBag
10 x 1001000
MicroMicro
Micro
Ultra-micro
Ultra-micro
Ultra-micro
SterilePackaging
100 μL Natural Yes Yes Rack 10 x 96Regular
100 μL Natural Yes Yes Rack 4 x 204Gel loading
FilterCapacityTip also fits Colour Style Unit QuantitySterilePackaging
20 μL Natural Yes Yes Rack 10 x 96Regular
20 μL Natural Yes Yes Rack 4 x 204Gel loading
20 μL
B, BT, E, F, G
B, BT, E, F, G
B, BT, E, F, G
B, BT, E, F, G
B, BT, E, F, G Natural Yes YesBag, single wrapped
5 x 100Regular
FilterCapacityTip also fits Colour Style Unit QuantitySterilePackaging
The Qualitips® pipette tips
from 10 μL to 10 mL
Product advantages
Wide selection, superior quality Lot-by-lot consistency Bulk or rack availability Compatibility with various pipette brands High-density filter prevents aerosol contamination DNAse and RNAse-free filter tips Pyrogen-free sterile filter tips
Ask for free samples
www.socorex.com
34
Size QuantityCat. No.
B, BT, E, F, G
B, BT, E, F, G
B, BT, E, F, G
308.0200R
308.0200B
307.0200R
307.0200B
B, BT, E, F, G
B, BT, E, F, G
327.0200R
327.0200B
B, BT, E, F, G
B, BT, E, F, G
B, BT, E, F, G
B, BT, E, F, G
328.0200R
328.0200B
309.0200R
309.0200B
B, BT, E, F, G
1) hinged lid
308.0200GR
B, BT, E, F, G
B, BT, E, F, G
308.0200LFS
308.0200LFR
B, BT, E, F, G
B, BT, E, F, G
329.0200R
329.0200B
B, BT, E, F
B, BT, E, F, G
309.1000FR
309.1000AFB
Qualitips 200 μL
SizeCat. No.
B, BT, E, F, G
B, BT, E, F, G
308.0350R
308.0350B
B, BT, E, F, G
B, BT, E, F, G
308.0300AFB
308.0300FR
Qualitips 300 / 350 μL
Size UnitCat. No.
B, BT, E, F, G
B, BT, E, F, G
307.1000R
307.1000B
B, BT, E, F, G
B, BT, E, F, G
309.1000R
309.1000B
Qualitips 1000 μL
B, BT, E, F 309.1000FR
B, BT, E, F, G 309.1000AFB
B, BT, E, F, G
B, BT, E, F, G
319.1000R
319.1000B
B, BT, E, F, G
51.1 mm
49.4 mm
49.4 mm
49.0 mm
49.7 mm
69.0 mm
90.9 mm
49.7 mm
88.6 mm
58.8 mm
58.8 mm
79.0mm
72.0 mm
72.0 mm
69.5 mm
B, BT, E, F, G
318.1000R
318.1000B
FilterCapacityTip also fits Colour Style Unit
200 μL
200 μL
200 μLB, BT, E, F, G
200 μL
Natural
Natural
Natural
Natural
No
No
No
No
No
No
No
No
Rack
Bag
Rack1)
Bag
10 x 96
1000
10 x 96
2 x 500
Regular
Regular
Graduated
Graduated
200 μL
200 μL
Yellow
Yellow
No
No
No
No
Rack1)
Bag
10 x 96
2 x 500
Graduated
Graduated
200 μL
200 μL
200 μL
200 μL
Yellow
Yellow
Natural
Natural
No
No
No
No
No
No
No
No
Rack
Bag
Rack
Bag
10 x 96
2 x 500
10 x 96
2 x 500
Regular
200 μL Natural No No Rack 4 x 204Gel loading
200 μL
200 μL
Natural
Natural
Yes
Yes
Yes
Yes
Bag, single wrapped
Rack
5 x 100
8 x 204
Extended
Extended
Regular
Regular
Regular
200 μL
200 μL
Yellow
Yellow
No
No
No
No
Rack
Bag
10 x 96
2 x 500
Regular
Regular
Sterile
1000 μL
1000 μL
Natural
Natural
Yes
Yes
Yes
No
Rack
Bag
10 x 100
1000
Regular
Regular
Packaging
FilterCapacity Colour Style Unit Quantity
350 μL
350 μL
Natural
Natural
No
No
No
No
Rack
Bag
10 x 96
1000
Regular
Regular
300 μL
300 μL
Natural
Natural
Yes
Yes
No
Yes
Bag
Rack
1000
10 x 96
Regular
Regular
SterilePackaging
FilterCapacity
Tip also fits
Tip also fits Colour Style Quantity
1000 μL
1000 μL
Natural
Natural
No
No
No
No
Rack1)
Bag
10 x 60
4 x 250
Graduated
Graduated
1000 μL
1000 μL
Natural
Natural
No
No
No
No
Rack
Bag
8 x 60
4 x 250
Regular
Regular
SterilePackaging
1000 μL
1000 μL
Blue
Blue
No
No
No
No
Rack
Bag
8 x 60
4 x 250
Regular
Regular
1000 μL
1000 μL
Blue
Blue
No
No
No
No
Rack
Bag
8 x 60
4 x 250
Regular
Regular
Description
Description
Description
Tip also fitsCat. No.
F
E
312.10
312.02
G
150.0 mm
115.5 mm
123.2 mm
G
312.05R
312.05B
Qualitips 2 / 5 / 10 mLFilterCapacity Colour Style Unit Quantity
10 mL
2 mL
Natural
Natural
No
No
No
No
Bag
Bag
3 x 100
2 x 250
Regular
Regular
5 mL
5 mL
Natural
Natural
No
No
No
No
Rack
Bag
2 x 50
2 x 250
Graduated
Graduated
SterilePackagingDescription
Size
Tip fitting: B = Brand®, BT = Biohit®, E = Eppendorf®, F = Finnpipette®, G = Gilson®. Brand names belong to their respective owners.
309.0010B + R
309.0010FR
302.0020B + R
302.0010FR + AFB
302.0010GR
307.1000B + R
309.1000B + R
319.1000B + R
318.1000B + R
309.1000FR + AFB
308.0020FS + FR
308.0020GFR
up to 1
0 µ
L
10 Y
/ 15 /
20 µ
L
25 to 1
00 µ
L
120 to 2
00 µ
L
250 to 1
000 µ
L
0.1
– 2
µL
0.5
– 1
0 µ
L
1 –
10 µ
L (Y
)
2 –
20 µ
L
5 –
50 µ
L
10 –
100 µ
L
20 –
200 µ
L
100 –
1000 µ
L
0.2
– 2
mL
0.5
– 5
mL
1 –
10 m
L
0.5
– 1
0 µ
L
5 –
50 µ
L
20 –
200 µ
L
40 –
350 µ
L
0.2
– 2
µL
1 –
10 µ
L
1 –
10 µ
L (Y
)
2 –
20 µ
L
10 –
100 µ
L
20 –
200 µ
L
100 –
1000 µ
L
0.2
– 2
mL
1 –
10 m
L
1 –
10 µ
L
10 –
100 µ
L
20 –
200 µ
L
Acura® manual and Acura® electro Calibra® digital
815 825 / 925 835 / 935 832 852855 / 955 822
Microtips, 20 µL
Microtips, 100 µL
308.0100FR
308.0100GFR
307.0200B + R
327.0200B + R
308.0200B + R
309.0200B + R
329.0200B + R
328.0200B + R
308.0200GR
308.0200LFS + LFR
308.0350B + R
308.0300FR + AFB + AFR
312.02 (2 mL)
312.05B + R (5 mL)
312.10 (10 mL)1) Only to max. volume of the tip 2) As of serial number 09091001 3) > 2 µL only
Microtips, 200 µL
Microtips, 300 / 350 µL
Microtips, 1000 µL
Microtips, 10 µL
Macrotips
x x x
x
x
xx
x
x
x
x x x x
x x
x x
x
x
x
x
x
x xx x x x xx x xx
x xx
x x xx
x x xx
x x xx
x x xx
xx
xx
xx
xx
x x x
x
x
xx
xx
xx
xx
xx
x x x xx
x x x xx
x x x x
x
x
x x x
x x
x
xx
x x xx
x xx
x xx
x x
x
x
x
xx
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
xx
x
x
xx
x
x
x
x
x x x
x
x x
x
x
x
x x
x
x
x
x x x
x
x
x
x
x
x
x3)
x3)
x1)
x1)
x1) x x1)
x1)
x1) x1)x1)
x1)
x1) x x1)
x1)x1)
x2)
x2)
x2)
x2)
x3)
35
Qualitips®compatibility chart
Chart below indicates optimal combination of Qualitips® and Socorex® pipette. Detailed compatibility with other pipette brandsavailable on request. Please contact your local distributor or Socorex.
pipette tipsQualitips
www.socorex.com
36
consumablesQualitips
Autoclaving boxes for Qualitips®
Empty boxes for autoclaving tipssupplied in bags.
All purpose reagent reservoirs
Particularly well suited for single and multichannel pipetting. Various shape, material and capacity provides ideal solutions for many applications.
Nozzle filters for pipettes
Added protection against liquid fill or pipette contamination. Filters areinterchangeable, non sterile, non autoclavable.
VolumeSize Colour StyleCat. No.
58x132x25 mm83x121x34 mm83x126x13 mm83x126x13 mm
70 mL125 mL40 mL40 mL
NaturalNaturalWhiteWhite
NoHinged lid
NoNo
PPPPPSPS
NoNoYesYes
20 / pk20 / pk
10x 1 / pk10x 1 / pk
330.01330.01L330.08.9330.12.9
V-shapedV-shaped8-channel12-channel
Lid Materials SterilePackagingDescription
Straw tips
For Acura® manual 810 dilution pipette.Long shape (190 x 4 mm) allows pickupof particle containing liquids in Stomacher®bags without blocking. Supplied sterilein re-sealable bags of 25 tips.
Description
Straw tips, natural, sterile
Packaging
20x 25 / pk
Cat. No.
313.1100
Glass Pasteur pipette
Fit Acura® manual 835, Acura® electro935 and Calibra® digital 832macropipettes with correspondingadapter. Long and thin alternative(150 x 7 mm) to PP macrotips.
Description
Pasteur pipette, glass, 2 mL
Packaging
250 / pk
Cat. No.
313.02
Description
Box with hinged lidfor 10 μL tips 309.0010BBox with lidfor tips 10 μL 302.0020BBox with lidfor 200 μL tips 328.0200BBox with lidfor 350 μL tips 308.0350BBox with lidfor 1000 μL tips 319.1000BBox with hinged lidfor 10 mL tips 312.10
Packaging
10 / pk
10 / pk
10 / pk
10 / pk
8 / pk
4 / pk
Cat. No.
309.0010ER
302.0020ER
328.0200ER
308.0350ER
319.1000ER
312.10ER
Description
Acura® 810Calibra® 832, 2 mLAcura® 835, 2 and 5 mLAcura® 935, 5 mLCalibra® 832, 10 mLAcura® 935, 10 mL
PECelluloseCellulose
PP fibres
PackagingFits Material
100 / pk250 / bag250 / bag
100 / bag
Cat. No.
322.810322.02322.05
322.10
manualmanual
manualelectro
electrodigital
1
6
6
1 2 3
2
4
4 5
5
3
service programmeSocorex Service Center
37
Broad calibration programme
Whatever the maintenance level neededfor micropipettes and dispensers,Socorex has the appropriate answer,including customised service planswhen required.
Efficient handling
The lead time for instruments receivedat Socorex is three to five working days,or 48 hours using our “Express service”.
Service Center on the web
For more details about our serviceprogramme, check: www.socorex.com
Personalised technical support
Highly qualified personnel with a broadproduct knowledge is at disposal for all technical matters. The team alsoprovides professional answers andsolutions about handling, maintenanceand control procedures.
SCS laboratory
Accredited by SAS (Swiss AccreditationServices) of the Federal Office ofMetrology, the Socorex QC laboratoryperforms calibrations in full compliancewith ISO 17025 and delivers controlcertificates recognised internationallyby ILAC members.
Examples of ILAC members
from signatory countries
Advantages
Know-how and high competence All-brand service for pipettes and dispensers Broad programme Controls according to ISO 8655 and ISO 17025 standards SAS accredited QC laboratory
Socorex instruments are built to last. In order to guaranteetrouble-free usage over time, a minimum maintenance and regularcalibration are strongly recommended. From basic repair to GLPrequirements, the Socorex Service Center – in its ultra-modernfacilities – provides fast and reliable service and calibration, basedon long-term experience in manufacturing precision liquidhandling instruments.
OrganisationCountry
AustraliaAustriaBelgiumBrazil
CanadaChina
China HKCroatia
Czech RepublicDenmarkFinlandFrance
GermanyHungary
IndiaIndonesia
IrelandItaly
JapanNetherlands
NorwayPoland
PortugalSouth Africa
SloveniaSpain
SwedenSwitzerland
TurkeyUnited Kingdom
USA
NATABMWABELAC
CGCRE / INMETROSCC-CLAS
CNASHKASHAACAI
DANAKFINAS
COFRACDKDNATNABLKANINABSIT
IA-JAPANRvANAPCAIPAC
SANASSA
ENACSWEDAC
SASTURKAK
UKASNVLAP
Complete list and details under www.ILAC.org
Dear Partner in science,
Welcome to Socorex – a world of expertise in precision liquid handling.
Having our catalogue in yourhands – and on your shelf – willmean a lot to you when it comes tochoosing the best liquid handlingproducts for your applications.These pages will guide you througha wide selection of innovative,ergonomic and safe instruments,engineered and designed withexcellence in mind for the mostdemanding scientists.
An early leader, Socorex was the first manufacturer to obtain the EN ISO 9001 certification inthis field, back in February 1991. This is only one of the many milestones having made total quality acompany tradition and a culturalway-of-life for our management and staff members all together.
Well trained, documented andequipped to provide professionaladvice and technical support, the reliable network of authoriseddistributors represents anotherSocorex key quality asset.
But the millions of Calibra® andAcura® pipettors and other famousSocorex instrument brands in usethroughout the world would meanlittle, be it for our ever-growingnumber of customers and theirproven satisfaction.
Thank you for your trust, we arecommitted to stay your qualitypartner in liquid handling.
Sylvain Christen, CEO
Brief history
Socorex Isba SA, often referred toas just Socorex, was first founded inthe late 1940s. Two youngwatchmakers had identified the needfor new types of quality syringes formedical applications. The productsrapidly met international success.
In search for synergies, the companymerged with another firm a fewyears later.
Renamed Socorex Isba S.A., the newentity moved to Lausanne on LakeGeneva in 1960.
Its growth, particulary in thelaboratory field, soon forced thecompany out of the city to itstoday’s larger, expandable facilityin Ecublens, home of the FederalInstitute of Technology (EPFL) andUniversity of Lausanne (UNIL).
Sylvain Christen, CEO
Laurence Louy-Drevici,Business Development
Natalie Frischknecht, Customer Service Coordinator
Jean-Pierre Uldry, Director of Engineering
Prisca Buchs,Customer Service
Thérèse Valenziano,Customer Service
Welcome to Socorex – a world of expertise in prec
www.socorex.com
38
ProceduresService levels Maintenance and control per ISO 8655
Standard
• • • • • • • •
• • • •
10 x 10 x
10 x 2)
10 x 10 x
10 x 10 x
10 x 2)
10 x 10 x
10 x
10 x 2)
10 x
10 x
10 x 2)
10 x
ISO 17025
10 x
10 x 2)
10 x
10 x
10 x
10 x 10 x
10 x 2)
10 x
4 x 1)
4 x 1) 10 x
10 x
10 x 2)
10 x
• • • •
• • • •
-
-
--
• • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
• • • • •
• •
• • •
•
•
• • • • •
• • • •
Classic Premium Advanced Ultra Ultra SCS
1) Five measurements below 50 μL 2) When applicable
Instrument registration
Gravimetric test beforemaintenance (“as found”)
Decontamination, disinfection,disassembling, cleaning
Instrument check-up
X-ring replacement as needed
Other faulty parts replacement as needed
Function and tightness check
Gravimetric test aftermaintenance per ISO 8655
Gravimetric test after maintenance per ISO 17025
Final check and visa
QC certificate before maintenance (“as found”)
QC certificate after calibration (“as left”)
Accredited certificate per ISO 17025
Min. vol.
Min. vol.
Mid. vol.
Mid. vol.
Max. vol.
Mid. vol.
Max. vol.
Min. vol.
Max. vol.
Classic SCS Premium SCS New instruments
Accredited calibration per ISO 17025
Accreditedcertificate
to beordered
withinstrument
Service programme
Standard serviceRepair, maintenance, control and calibration,
2x4 measurements, with QC certificate.
The cost-effective solutionfor any liquid handling instrument.
Classic serviceCleaning and maintenance,
control and calibration, 2x 10measurements, with detailed
QC certificate.
Recommended as routine check.
Classic SCS serviceSame as above, but withISO 17025 calibration and SCS accredited certificate.
Alternative routine check whendealing with ISO 17025
procedures, or whenmastering uncertainties
is required.Ultra SCS service
Same as above with ISO 17025 calibration and SCS accredited certificate.
Ultimate service when dealing with ISO 17025 for GLPenvironment demanding analytical results.
Premium SCS serviceSame as above, but with
ISO 17025 calibration andSCS accredited certificate.
A must for laboratories dealing with ISO 17025 procedures, or
when mastering uncertainties isrequired. Available for new
instruments as well.
Premium serviceCleaning and maintenance,control and calibration, 3x10
measurements, with detailed QC certificate.
An in-depth check, also including mid-range measurements.
A choice of service levels
Advanced serviceControl, 2x10 measurements, with
detailed certificate before maintenance (“as found”). Then cleaning, maintenance and calibration,
2x10 measurements, with detailed QC certificate.
Perfect for instruments used in GLP environments or for validation of critical analytical results.
Ultra serviceControl, 3x 10 measurements, with detailed certificate beforemaintenance (“as found”). Then cleaning, maintenance and
calibration, 3x10 measurements, with detailed QC certificate.
Ultimate service for GLP environment when analytical results are demanded.
Products & services
Today’s manufacturing programmeincludes a wide variety of highprecision instruments used for reliablymeasuring, dosing, transferring,dispensing and injecting liquids in a large number of applications.
Manual and electronic micropipettes,multichannel pipettors, repeaterpipettes, dispensers, pipettecontrollers and re-usable syringes,together with their accessories,constitute the heart of the programme.
Each precision instrument bears itsown serial number and passes a strictperformance control attested by anindividual QC certificate.
“One stop does it all” is the mottoof the Socorex Service Center,offering a global repair andcalibration programme. The choicesrange from basic maintenance to accredited calibrationsof all micropipettes and dispensers according to ISO 17025– whatever their brand.
Yves Lachavanne, Marketingand Sales Support Manager
precision liquid handling
y o u r q u a l i t y p a r t n e r w o r l d w i d e
Electronic micropipettes
Digital setting micropipettes
Positive displacement micropipettes
Repeater pipette
Microdispenser pipettes
Bottle top dispensers
Low profile dispensers
Laboratory syringes
Graduated pipette aids
Instrument stands
Pipette tips / consumables
Service Center
Digital reading micropipettes
precision liquid handling
y o u r q u a l i t y p a r t n e r w o r l d w i d e
Electronic micropipettes
Digital setting micropipettes
Positive displacement pipettes
Repeater pipette
Microdispenser pipettes
Low profile dispensers
Bottle-top dispensers
Laboratory syringes
Pipette controllers
Work stations
Pipette tips / consumables
Service center
Digital reading micropipettes
SOCOREX ISBA SA
Champ-Colomb 7, P.O. Box
1024 Ecublens/Lausanne
Switzerland
www.socorex.com
Tel: +41 (0)21 651 6000
Fax: +41 (0)21 651 6001
C.G
EN.E
– C
409
Your local distributor
Important information
Refer to package inserts for safetyprecautions, operating instructionsand warranty terms.
User must pay special attentionto possible hand fatigue during serial pipetting and its medicalconsequences such as repetitivestrain injuries (RSI).
Mind risks involved in handlinghazardous liquids with respect to personal, third party andenvironmental protection and safety.
Products and specifications are subjectto change without prior notice.
Copyright © 2009 by Socorex ISBA SA, Switzerland
PR
EC
ISIO
N L
IQU
ID H
AN
DL
ING
2
00
9-2
01
0