16
PowerView AC Motor by LUXAFLEX ® WINDOW FASHIONS

PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

Embed Size (px)

Citation preview

Page 1: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

PowerView™ AC Motor by LUXAFLEX® WINDOW FASHIONS

Page 2: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,
Page 3: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

CONTENTS

GETTING STARTED

Getting Started ................................................................................................................ 1

Remote Control Overview ................................................................................................. 2

Using Multiple remotes within a home (Copying Network ID) .............................................. 4

Programming Overview.................................................................................................... 5

PROGRAMMING

STEP 1 — Join a Shade to a Group ................................................................................ 5

STEP 2 — Reverse the Motor Direction (If Necessary) ...................................................... 6

STEP 3 — Set the Motor Upper Limit ............................................................................... 6

STEP 4 — Set the Motor Lower Limit ............................................................................... 7

STEP 5 — Set a Favourite Position (Optional) ................................................................... 8

STEP 6 — Creating a Duplicate Remote ........................................................................... 8

STEP 7 — Test the Motors and PowerView Shade Network ............................................... 9

APPENDIX A

Clear Motor Limits ......................................................................................................... 10

Remove a Shade from a Group ....................................................................................... 10

Deactivate the remote’s auto-wake feature ..................................................................... 11

Reset Shade Network Programming ............................................................................... 11

Reset to Factory Default ................................................................................................. 11

Control the motor with Dry Contacts (M40 Motor only) ..................................................... 12

Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116, AustraliaPowerView has been certified as complying with ACMA'S regulatory requirements.

© Copyright 2016 Hunter Douglas Limited [ABN 98 009 675 709] ® Luxaflex, PowerView and Pebble are registered Trade Marks of Hunter Douglas •10/2016

Page 4: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,
Page 5: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

WARNING: Motors do not have default limits set. Limits must be set to enable normal operation. If operated without limits, the blind could be damaged by rolling over the top or wrapping backwards on the roller.

KEY COMPONENTSThe following items are required for single shade or multiple shade setup.

PowerView AC motor(s) with roller shade(s)

PowerView Pebble Remote or PowerView Surface Remote

Manual Control Button

M40 Series

Dry ContactInput

RF Antenna

Manual Control Button

RF Antenna

M50 Series

CAUTION: Do not damage the RF antenna. For best RF performance, the antenna should maintain as much separation from a

conductive surface as possible.

GETTING STARTED

1

GE

TT

ING

STA

RT

ED

Page 6: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

POWERVIEW™ PEBBLE® REMOTEErgonomically designed, the PowerView Pebble hand-held remote is available in seven on-trend colours to complement your home décor.

POWERVIEW SURFACE REMOTE The sleek PowerView Surface is wall-mounted so you know your remote is always right where you left it.

REMOTE MODULE FRONT

RIGHT ARROW Super Quiet Mode.

LEFT ARROW Super Quiet Mode.

Favourite Shade position

STOP Press and

hold for program

mode.

GROUP 1

GROUP 2

GROUP 3 GROUP 4

GROUP 5

GROUP 6

CLOSE

OPEN

REMOTE MODULE (BACK COVER REMOVED)

BATTERYCOMPARTMENT 3V CR 2032

BATTERYCOMPARTMENT

3V CR 2032

RESET BUTTON

REMOTE CONTROL OVERVIEW

2

RE

MO

TE

CO

NT

RO

L O

VE

RV

IEW

Page 7: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

REMOTE MODULE (BACK COVER REMOVED)

Important: The PowerView Remote will not operate a window covering until

the window covering has been added to a GROUP.

GETTING STARTED First, activate the remote by pulling both plastic tabs from the back battery

compartment.

Inserting the remote module into the PowerView Pebble

(hand-held):

1. Centre the Hunter Douglas logo on the remote module above the

indentation on the bottom rim of the Pebble.

2. Align the ribs on the remote module with the grooves on the Pebble.

3. Gently push the remote module into the Pebble until it

is snug.

MOUNTING THE POWERVIEW SURFACE:1. Choose a location to mount the Surface.

2. Orient the Surface mounting plate so that the Hunter Douglas logo

is horizontal and level. Mark screw holes.

3. If you are mounting the Surface onto drywall, use a 6mm drill bit

to drill pilot holes. Tap drywall anchors into the pilot holes until the

flange of the anchor is flush with the drywall.

4. If you are mounting the Surface onto wood, use a 3mm

drill bit to drill the screw holes.

5. Attach the Surface mounting plate using the screws provided.

6. Align the Surface ring with its mounting plate and twist the Surface ring clockwise to lock it in place. Inserting the

remote module in the Surface:

1. Align the ribs on the remote module with the grooves on the Surface.

2. Gently push the remote module into the Surface until it is snug.

REMOTE CONTROL OVERVIEW

3

RE

MO

TE

CO

NT

RO

L O

VE

RV

IEW

Page 8: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

Each PowerView Remote comes with its own unique Radio Frequency (Network) ID. If multiple remotes (ie. PowerView Pebble and/or PowerView Surface remotes) will be used in the home, it is necessary to establish a single PowerView Shade Network ID for all remotes before any window covering programming is done. This is to ensure that if a PowerView Hub, PowerView Scene Controller or PowerView Repeater(s) will be used in the future, it can be used to operate previously programmed window coverings in the home and be used in conjunction with all the remotes on a single, unified network.

1. SELECT the initial Network remote. This will be the source remote from which a unified PowerView Shade Network will be established for the home.

NOTE: As a unified network has not yet been established, it does not matter which available remote you choose to use to create a PowerView Shade Network.

2. SELECT the target remote.

3. REMOVE the back cover on the target remote.

4. Using a ball point pen, PRESS and HOLD the recessed Reset button on the back of the target remote for six seconds.

NOTE: The Group numbers (1-6) buttons will flash twice on the press of the Reset button, then again at six seconds.

5. REINSTALL the back cover onto the target remote.

6.PRESS and HOLD (Stop) on the source remote, until indicator lights begin to blink.

NOTE: This puts the source remote in Programming Mode. Indicator lights on the source remote will continue to blink for 20 seconds following each set of commands, allowing additional target remotes to be networked.

7. With the source remote in Programming mode, PRESS and continue to HOLD (Stop) on the target remote. Complete steps 8 and 9 at the same time.

8. PRESS and RELEASE (Stop) on the source remote.

9. RELEASE (Stop) on the target remote.

NOTE: The Group numbers (1-6) on the target remote will flash twice to indicate that it has been networked to the source remote.

10. PRESS and HOLD (Stop) on the source remote until the indicator lights stop blinking.

USING MULTIPLE REMOTES WITHIN A HOME (PAIRING REMOTES TO A SINGLENETWORK ID)

1. 2.

Source Target Target

5. 6.Source

3. 4.TargetTarget

8. 9.

Source

7.Target Target

10.Source

4

US

ING

MU

LIT

PL

E R

EM

OT

ES

Page 9: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

USING MULTIPLE REMOTES WITHIN A HOME (PAIRING REMOTES TO A SINGLENETWORK ID)

To program your PowerView AC motor and roller shade, you will need to perform the following 9 steps:

STEP 1: Join a Shade to a Group

STEP 2: Reverse the Motor Direction (If Necessary)

STEP 3: Set the Motor Upper Limit

STEP 4: Set the Motor Lower Limit

STEP 5: Set a Favourite Position (Optional)

STEP 6: Creating a Duplicate Remote

STEP 7: Test the Motors and PowerView Shade Network

STEP 1 — JOIN A SHADE TO A GROUP

1. Remote: press and hold STOP for 6 seconds to put the remote into program mode.

The backlit buttons on the remote will flash to

indicate it is in program mode.

2. Remote: press and release the desired GROUP

number (1 – 6).

The backlit GROUP number will flash to show it is

selected.

3. Motor: press and hold the manual control button

located on the motor head.

4. Remote: while continuing to press the manual control button,

press and release OPEN on the remote.

The shade will move twice to indicate it has joined the group.

5. Motor: release the manual control button.

6. Remote: press and hold STOP for 6 seconds to exit

program mode. The lights will stop flashing.

WARNING: The AC motor will not operate correctly until limits are set (Step 3 and Step 4).

5

PROGRAMMING OVERVIEW PR

OG

RA

MM

ING

OV

ER

VIE

W

Page 10: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

IMPORTANT: Be sure no end limits are set on the motor. If one or both limits are set, you cannot change the motor direction.

See Appendix A for instructions to clear limits.

1. Remote: deselect all GROUP numbers

2. Motor: press and hold the manual control button

located on the motor head.

3. Remote: while continuing to press the

manual control button, press and release STOP

on the remote.

4. The shade will move twice to indicate it has

reversed motor direction.

NOTE: If end limits were already set, the motor will not

move, indicating the motor direction did not change.

NOTE: Verify that all GROUP lights are turned off on the

remote, clear both limits, and try again.

5. Motor: release the manual control button.

3. SET THE MOTOR UPPER LIMIT

NOTE: When end limits are not set, the motor responds to OPEN or CLOSE on the remote with single, small

movements.

1. Move the shade to the desired upper limit.

On the remote, use the OPEN, CLOSE, or LEFT

or RIGHT ARROW buttons to fine tune desired

position.

On the motor, use the manual control button or dry

contact input (M40 Series only).

2. Remote: press and hold STOP for 6 seconds

to put the remote into program mode.

The backlit buttons on the remote will flash to

indicate it is in program mode.

3. Remote: deselect all GROUP numbers.

4. Motor: press and hold the manual control button

located on the motor head.

5. Remote: while continuing to press the manual

control button, press and release OPEN on the remote.

The shade will move twice to indicate the upper limit is set.

6. Motor: release the manual control button.

7. Remote: press and hold STOP for 6 seconds to exit program mode.

The lights will stop flashing. IMPORTANT: Verify that the upper limit is set. If not, deselect all GROUP numbers and

repeat Step 3.

NOTE: When end limits are not set, the motor responds to OPEN or CLOSE on the remote with single, small

movements.

IN PROGRAM MODE:

Deselect all GROUPnumbers.

IN PROGRAM MODE:

Deselect all GROUPnumbers.

6

2. REVERSE THE MOTOR DIRECTIONRE

VE

RS

E T

HE

MO

TO

R D

IRE

CT

ION

/ SE

T T

HE

MO

TO

R U

PP

ER

LIM

IT

Page 11: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

1. Move: the shade to the desired lower limit.

On the remote, use the OPEN, CLOSE, LEFT or RIGHT, ARROW to fine

tune desired position.

On the motor, use the manual control button or dry

contact input (M40 Series only).

2. Remote: press and hold STOP for 6 seconds to put the remote

into program mode.

The backlit buttons on the remote will flash to indicate it is in program

mode.

3. Remote: deselect all GROUP numbers.

4. Motor: press and hold the manual control button located on the

motor head.

5. Remote: while continuing to press the manual control button,

press and release CLOSE on the remote.

The shade will move twice to indicate the lower limit is set.

6. Motor: release the manual control button.

7. Remote: press and hold STOP for 6 seconds to exit program

mode.

The lights will stop flashing.

IMPORTANT: Verify that the lower limit is set. If not,

deselect all GROUP numbers and repeat Step 4.

NOTE: After the upper and lower limits are set, the motor will have one

Favourite position, which is set at 50% open by default. Setting a new Favourite position overwrites any previous

setting.

IN PROGRAM MODE:

Deselect all GROUPnumbers.

IN PROGRAM MODE:

Deselect all GROUPnumbers.

7

4. SET THE MOTOR LOWER LIMIT SE

T T

HE

MO

TO

R L

OW

ER

LIM

IT

Page 12: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

1. Move the motor to the desired position.

2. Remote: press and hold STOP for 6 seconds to

put the remote into program mode.

The backlit buttons on the remote will flash to

indicate it is in program mode.

3. Remote: deselect all GROUP numbers.

4. Motor: press and hold the manual control button

located on the motor head.

5. Remote: while continuing to press the manual control button, press

and release FAVOURITE on the remote. The shade will move twice to indicate it has set this shade position as your

FAVOURITE.

6. Motor: release the manual control button.

7. Remote: press and hold STOP for 6 seconds to exit

program mode.

The lights will stop flashing.

IMPORTANT: Verify that the FAVOURITE position is set at the desired position.

6. CREATING A DUPLICATE REMOTE

A duplicate remote will operate the same set of window coverings and GROUPS as the original remote.

1. Remove the back cover from the new remote.

2. Press and hold the recessed Reset button for 6 seconds, until the GROUP buttons flash two separate times. Reinstall the

back cover.

3. Press and hold STOP for 6 seconds on the original remote to put it in programming mode. The

backlit buttons on the remote will flash to indicate it is in programming mode.

4. While pressing and holding ALL on the new remote, press and release STOP on the original

remote.

5. The backlit group buttons on the duplicate remote will flash twice to indicate all of the

information from the original remote has been copied.

6. Press and hold STOP for 6 seconds on the original remote to exit program mode.

8

5. SET A FAVOURITE POSITIONSE

T A

FAV

OU

RIT

E P

OS

ITIO

N / C

RE

AT

ING

A D

UP

LIC

AT

E R

EM

OT

E

Page 13: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

Use the remote control to verify the following settings for all shades in the PowerView Shade Network.

Verify each shade is joined to the correct GROUP number.

Press ALL to move all shades.

Press GROUP 1 – 6 to select specific shades to operate.

1. Verify that the motor direction is correctly set for each shade.

Press ALL, then press OPEN on the remote.

All shades should move in the up direction.

2. Verify that the upper limit is correctly set for each shade.

Press ALL, then press OPEN on the remote.

All shades should stop at the correct upper limit.

3. Verify that the lower limit is correctly set for each shade.

Press ALL, then press CLOSE on the remote.

All shades should stop at the correct lower limit.

4. Verify that the FAVOURITE position is correctly set for each shade.

Press ALL, then press FAVOURITE on the remote.

All shades should stop at the correct FAVOURITE position.

7. TEST THE MOTORS AND POWERVIEW SHADE NETWORK

9

TE

ST

TH

E M

OT

OR

S A

ND

PO

WE

RV

IEW

SH

AD

E N

ET

WO

RK

Page 14: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

Clear Top Limit

1. Remote: deselect all GROUP numbers.2. Motor: press and hold the manual control

button located on the motor head.3. Remote: while continuing to press the manual

control button, press and release OPEN on the remote. The shade will move twice to indicate the upper limit is cleared. 4. Motor: Release the manual control button.

NOTE: To set Top Limit refer to Step 3.

Clear Lower Limit

1. Remote: deselect all GROUP numbers.

2. Motor: press and hold the manual control button located on the motor head.

3. Remote: while continuing to press the manual control button, press and release CLOSE on the remote.

The shade will move twice to indicate the lower limit is cleared.

4. Motor: Release the manual control button.

NOTE: To set Top Limit refer to Step 4.

REMOVE A SHADE FROM A GROUP

NOTE: Only one GROUP number can be removed at a time.1. Remote: press and hold STOP for 6 seconds to put the remote into program mode. The backlit buttons on the remote will flash to indicate it is in program mode. 2. Remote: press the desired GROUP number (1 – 6). The backlit GROUP number will flash to show it is selected.3. Motor: press and hold the manual control button located on the motor head.4. Remote: while continuing to press the manual control button, press and release CLOSE on the remote. The shade will move twice to indicate it has been removed from the group.5. Motor: Release the manual control button.6. Remote: Press and hold STOP for 6 seconds to exit program mode. The lights will stop flashing. NOTE: To add shade to a new group refer to Step 1.

IN PROGRAM MODE:

Deselect all GROUPnumbers.

IN PROGRAM MODE:

Deselect all GROUPnumbers.

10

CLEAR MOTOR LIMITS

IN PROGRAM MODE:

One GROUP numbermust be selected.

CL

EA

R M

OT

OR

LIM

ITS

/ RE

MO

VE

A S

HA

DE

FR

OM

A G

RO

UP

Page 15: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

11

DEACTIVATING THE REMOTE’S AUTO-WAKE FEATUREThe auto-wake feature activates the backlights on the remote, whenever the remote is handled. This feature is useful for

immediately seeing which shade group buttons were activated last, but deactivating this feature will help to conserve battery

life.

1. PRESS and HOLD the Group 6 button on the remote for approximately six seconds.

2. The Group numbers (1-6) will blink once to indicate the auto-wake feature has been disabled.

3. To reactivate the Auto-wake feature follow step 1.

RESET SHADE NETWORK PROGRAMMING

The shade network programming reset erases all remote GROUP assignment programming stored in the shade. The reset will

also remove the shade from its current PowerView Shade Network, preventing any input device from operating the shade. The

primary use is during installation to correct GROUP and Network assignments. This reset does not affect motor limits, motor

direction, or the FAVOURITE position.

1. Motor: press and hold the manual control button located on the motor head for 12 seconds.

The shade will move twice after 6 seconds, then again after 12 seconds.

2. Motor: Release the manual control button.

Refer to “JOIN A SHADE TO A GROUP” refer to step 1.

RESET TO FACTORY DEFAULT

The factory default reset erases all information stored in a shade motor. The motor is returned to its factory default settings

of no network programming, no limits, and the motor direction is reset. The default FAVOURITE position will be at 50% after

limits are set.

1. Motor: press and hold the manual control button located on the motor head for 18 seconds.

The shade will move twice after 6 seconds, then again after 12 seconds, and then again after 18 seconds.

2. Motor: Release the manual control button.

Refer to “JOIN A SHADE TO A GROUP” Stage 1 to program the shade into a group, then reverse motor direction (if

necessary), set limits, and set a new FAVOURITE position (optional).

DE

AC

TIVA

TE

RE

MO

TE

/ /RE

SE

T N

ET

WO

RK

/ RE

SE

T FA

CT

OR

Y D

EFA

ULT

Page 16: PowerView AC Motor - alfi.hunterdouglas.com.aualfi.hunterdouglas.com.au/pdf/PowerView ROLLER AC Motor Quick St… · Hunter Douglas Australia 338 Victoria Rd Rydalmere, NSW, 2116,

12

Manual Control Button

Dry ContactInput

RF Antenna

Manual Control Button

Dry ContactInput

RF Antenna

CLOSECOMMON

OPEN

Open

Short the OPEN dry contact to COMMON and then release.

The motor moves in the OPEN direction.

CloseShort the CLOSE dry contact to COMMON and then release.

The motor moves in the CLOSE direction.

StopWith the motor moving, short the OPEN or CLOSE dry contact to common and

then release.

This stops the motor, if the motor is moving in the direction of the dry contact

command that is shorted.

Alternate STOP (short all 3 contacts)

Simultaneously short the OPEN and CLOSE dry contacts to COMMON for less

than 1.5 seconds, then release.

This stops the motor, if the motor is moving.

Go to the FAVOURITE Position (short all 3 contacts)

Simultaneously short the OPEN and CLOSE dry contacts to COMMON for more than 1.5 seconds, then release.

The motor goes to the FAVOURITE position (if both end limits are set).

CONTROL THE MOTOR WITH DRY CONTACTS (M40 SERIES MOTOR ONLY)CO

NT

RO

L T

HE

MO

TO

R W

ITH

DR

Y C

ON

TAC

TS