Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
Raptor Power Systems | (800) 258-0129 | www.raptorpower.us | [email protected]
][Crypto Powering New Generation Miners
T
Unparalleled Density
Lower Set Up and Installation Costs
Future Proofed
Remote Control
USA Manufacturing
Raptor Power Systems | (800) 258-0129 | www.raptorpower.us | [email protected]
][Crypto Powering New Generation Miners
Control and Monitoring Descrip on Speci ca on Communica on Port Type (Ethernet, serial, USB, Wireless, 4G LTE)
Op onal
Communica on Protocol (Webpage IP Addressable, SNMP, HTTP API Commands, Standalone Windows So ware)
Op onal
Control (on/o control for each output, total system or a speci c group of outputs)
Op onal
Monitoring (temp, humidity, current, voltage for each output, total system or a speci c group of outputs)
No
Output Speci ca ons Descrip on Speci ca on Type of outputs and quan ty of each (NEMA, IEC, terminals etc.)
24 x C-13 OR 24 x C-19 OR 24 x 7-15R
Voltage 208V, 240V, 277V Do the outputs need to be in speci c banks? Yes – 2 outlets per bank LCD Meter (volts, amps, temp) No Circuit Breaker (current ra ng and either switched standard, switched illuminated, switched standard with LED indica on or push bu on pop breakers)
12 x 50A Switched Circuit Breakers
Circuit Breaker Type (UL 489, UL 1077) UL 1077 Do the circuit breakers need to be in speci c banks?
Yes – 1 Circuit Breaker per 2 Outlets
On/O switches for outputs (not current protected)
No
Physical/Environmental Descrip on Speci ca on Enclosure Type (rack, wall, standalone etc.) 0U Dimension/size restraint 38 x 6 x 4 Material Type (aluminum/steel) Alm/Stl Opera ng Environment (temp, humidity, IP ra ng)
0-45C
Radiated EMI Protected Enclosure No
Input Speci ca ons Descrip on Speci ca on Single or Dual Input Single Voltage 208V, 240V, 415V, 480V Current 384 Amps Input Connector Internal Hardwire Frequency (25Hz, 50Hz, 60Hz, 100Hz, 400Hz) 50/60Hz Circuit Breaker (current ra ng and either switched standard, switched illuminated, switched standard with LED indica on or push bu on pop breakers)
No
Circuit Breaker Type (UL 489, UL 1077) N/A Power Cord Type (SOOW, etc.) N/A Power Cord Length N/A LCD Meter (volts, amps, temp) N/A
33.00
5.12
4.00
2.02
Installation, Warnings,& Usage Instructions
128A Power StripRPS-PDU-CM-5
NOTE: Before installation read these instructions carefully and completely. These installationinstructions can not cover every possible installation, operation or maintenance situation.
NOTE: This Power strip is constructed in accordance with UL 62368-1.
WARNING: Never work on power strip if power is applied!
WARNING: Do not exceed 60C ambient operating temperature.
1. Prior to applying power on mains put all output circuit breakersinto the OFF position.2. Apply power via upstream 150A (wye) per phase UL 489 circuit breaker.3. Set output ciruit breakers to the ON position in the correspondingbanks that are to supply power to connected loads.
Usage Instructions
Powerspec Inc. 25 4th Street Somerville, NJ 08876 (800) 258-0129DOC# RPS-PDU-CM-5
Mounting Instructions1. Power strip is to be permanently mounted withvendor supplied mounting brackets.2. Use only supplied hardware for mounting3. To be installed by a quali�ed personnel according to local code
1. Do not exceed 128 amps on any single input connector.2. Ensure input and output power connections are secure.3. Never detach input or output power while load is active.4. Only supply power that is circuit protected upstream to a maximum of 150A.5. Disconnect device shall be provided as part of the building installation
Electrical Precautions
1. Remove access panel located at top of unit.2. Insert power cord through top entry strain relief.3. Power cord should be a minimum of 1/0 per conductor.4. Attach bare wire ends of the conductors and ground to the corresponding contact and hand tighten.5. Replace access panel cover.
Input Power Connection
! WARNING: Reduced Air Flow - Installation of the equipment in a rack should be such that theamount of air�ow required for safe operation of the equipment is not compromised.
! WARNING: Mechanical Loading - Mounting of the equipment in the rack should be such that ahazardous condition is not reached due to uneven mechanical loading.
!WARNING: Circuit Overloading - Consideration should be given to the connection of theequipment to the supply circuit and the e�ect that overloading of the circuits migh have onover-current protection and supply wiring. Appropriate consideration of equipment nameplateratings should be used when addressing this concern. For North America permissible loads,refer to Article 210.23 of the National Electrical Code.
! CAUTION: Failure to properly ground this PDU or fully insert the PDU into the equipment rackcan create a hazardous condition to the installer and the equipment.
! CAUTION: Prior to connecting input power cables, ensure that the upstream power is turned o�.
!WARNING: Elevated Ambient Temperature - If installed in a closed or multi-rack unit assembly,the operating ambient temperature of the rack environment may be greater than room ambient. Considerations should be given to installing the equipment compatible with themaximum rated ambient temperature.
PARTS LISTDESCRIPTIONPART NUMBERQTYITEM
CHASSIS BODYC041119-11180 AMP SINGLE POLE BREAKER - DIN RAILASSEMBLY
12
CHASSIS LID ASSEMBLYC041119-213POWER DISTRIBUTION BLOCK 400 AMP RATEDLK40044DIN RAIL 35 MM - 4.5" LONGDINR4.5I25
C041119-316QUALTEK C-19 RECEPTICAL746W-15/08247HEYCO LIQUID TIGHT CORD GRIPMXXX18100° Flat Countersunk Head Machine Screw -UNC - Inch
ANSI B18.6.3 - 8-32 UNC x 0.2549
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET 1 OF 1
DRAWN
CHECKED
QA
MFG
APPROVED
M.T. 4/10/2019
DWG NO
C041019-1
TITLE
C041019-1
SIZE
Custom Size (inches)SCALE
RAPTOR POWER SYSTEMS
REV
A
33.00
5.12
2.03
2.56
9
6
7
2
4
8
REVISION HISTORYREV DESCRIPTION DATE APPROVED
A INITIAL RELEASE FOR REVIEW 4/11/2019 EEK
CHASSIS MATERIAL: 16 GAUGE 5052 ALUMINUMFINISH: FLAT BLACK POWDER COAT
.
A
.
B
.
C
.
G
50A
.
A
.
B
.
C
.
N
.
G
50A
4 WIRE
5 WIRE
x12 BANKS
4 AB, 4 BC, 4 CA
OUTLET OPTIONS
24 x C-13 (max current 15 A)
24 x C-19 (max current 20 A)
24 x 7-15R (max current 15 A)
x12 BANKS
4 AN, 4 BN, 4 CN
Input/Output Configurations
Input Configuration Output
Max Load Per
Outlet
120/208V 5 wire 120 V 2400 W
120/208V 4 wire 208 V 4100 W
240/415V 5 wire 240 V 4800 W
277/480V 5 wire 277 V 5540 W
8
A
B
7 6 5
C
8
D
7 6 5
DATE
4 3 2
SCALE
SIZE DWG NO.
SHEET
1
REV
A
B
4 3 2
ZONE REV
C
1
REVISIONS
DESCRIPTION
D
APPROVEDDATE
THIS DRAWING IS THE
PRIVATE AND CONFIDENTIAL
PROPERTY OF RAPTOR
POWER SYSTEMS AND MUST
NOT BE LOANED, COPIED, OR
REPRODUCED WITHOUT
WRITTEN PERMISSION, AND
MUST BE RETURNED TO
RAPTOR POWER SYSTEMS
UPON REQUEST
Raptor Power Systems
CryptoMinotaur
James Norcross
PN: RPS-PDU-CM-4/RPS-PDU-5
10/16/19
A
Initial Release 10/16/19 EEK