POWER FACTOR CORRECTION

  • Upload
    deion

  • View
    95

  • Download
    3

Embed Size (px)

DESCRIPTION

POWER FACTOR CORRECTION. HASHMAT ALI SHAH STUDENT ID 3205388. OUTLINE. DEFINITION CAUSES OF LOW POWER FACTOR POWER FACTOR CORRECTION ADVANTAGES OF POWER FACTOR CORRECTION DISADVANTAGES OF LOW POWER FACTOR CONCLUSION REFERENCES. DEFINITION: - PowerPoint PPT Presentation

Citation preview

11

POWER FACTOR CORRECTIONPOWER FACTOR CORRECTION HASHMAT ALI SHAHHASHMAT ALI SHAH

STUDENT ID 3205388STUDENT ID 3205388

22

OUTLINEOUTLINE

DEFINITIONDEFINITION

CAUSES OF LOW POWER FACTORCAUSES OF LOW POWER FACTOR

POWER FACTOR CORRECTIONPOWER FACTOR CORRECTION

ADVANTAGES OF POWER FACTOR CORRECTIONADVANTAGES OF POWER FACTOR CORRECTION

DISADVANTAGES OF LOW POWER FACTORDISADVANTAGES OF LOW POWER FACTOR

CONCLUSIONCONCLUSION

REFERENCESREFERENCES

33

DEFINITION:DEFINITION: Power factor (P.F) is the ratio between actual power to Power factor (P.F) is the ratio between actual power to

the apparent power.the apparent power. Actual power/Apparent power.Actual power/Apparent power. P.F=Kw /Kva.P.F=Kw /Kva. For a purely resistive load the power factor is unity. Active For a purely resistive load the power factor is unity. Active

and reactive power are designated by P &Q respectively. and reactive power are designated by P &Q respectively. The average power in a circuit is called active power and The average power in a circuit is called active power and the power that supplies the stored energy in reactive the power that supplies the stored energy in reactive elements is called reactive power.elements is called reactive power.

44

Active Power:: Also known as “real power” or simply “power.” Active power Also known as “real power” or simply “power.” Active power

is the rate of producing, transferring, or using electrical is the rate of producing, transferring, or using electrical energy. It is measured in watts and often expressed in energy. It is measured in watts and often expressed in kilowatts (KW) or megawatts (MW). The terms “active” or kilowatts (KW) or megawatts (MW). The terms “active” or “real” power are used in place of the term “power” alone to “real” power are used in place of the term “power” alone to differentiate it from “reactive power.differentiate it from “reactive power.

Apparent Power: The product of the voltage (in volts) and the current (in amperes). It comprises both active and reactive power . It is measured in “volt-amperes” and often expressed in “ kilovolt-amperes” (KVA) or “megavolt-amperes” (MVA).

55

POWER FACTOR DEFINITIONPOWER FACTOR DEFINITION

Inductive loads cause the current to lag behind the Inductive loads cause the current to lag behind the voltage. The wave forms of voltage and current are then voltage. The wave forms of voltage and current are then "out of phase" with each other. The more out of phase "out of phase" with each other. The more out of phase they become then the lower the Power Factor. Power they become then the lower the Power Factor. Power Factor is usually expressed as Cos Phi. (Ø)Factor is usually expressed as Cos Phi. (Ø)

66

Consider a canal boat being pulled by a horse. Consider a canal boat being pulled by a horse. If the horse could walk on water then the angle (Phi) Ø If the horse could walk on water then the angle (Phi) Ø

would be zero and COSINE Ø=1. Meaning all the horse would be zero and COSINE Ø=1. Meaning all the horse power is being used to pull the load. power is being used to pull the load. However the relative position of the horse influences the However the relative position of the horse influences the power. As the horse gets closer to the barge, angle Ø1 power. As the horse gets closer to the barge, angle Ø1 increases and power is wasted, but, as the horse is increases and power is wasted, but, as the horse is positioned further away, then angle Ø2 gets closer to positioned further away, then angle Ø2 gets closer to zero and less power is wasted.zero and less power is wasted.

77

CAUSES OF LOW POWER FACTORCAUSES OF LOW POWER FACTOR

A poor power factor can be the result of either a A poor power factor can be the result of either a significant phase difference between the voltage and significant phase difference between the voltage and current at the load terminals or it can be due to a high current at the load terminals or it can be due to a high harmonic content or distorted/discontinuous current harmonic content or distorted/discontinuous current waveform. Poor load current phase angle is generally the waveform. Poor load current phase angle is generally the result of Poor load current phase angle is generally the result of Poor load current phase angle is generally the result of an inductive load such as an induction motor result of an inductive load such as an induction motor power transformer, lighting ballasts, welder or induction power transformer, lighting ballasts, welder or induction furnace, Induction generators Wind mill generators and furnace, Induction generators Wind mill generators and high intensity discharge lightings.high intensity discharge lightings.

88

CAUSES OF LOW POWER FACTORCAUSES OF LOW POWER FACTOR

A distorted current waveform can be the result of a A distorted current waveform can be the result of a rectifier variable speed drive, switched mode power rectifier variable speed drive, switched mode power supply, discharge lighting or other electronic loadsupply, discharge lighting or other electronic load. .

99

POWER FACTOR CORRECTIONPOWER FACTOR CORRECTION

Power factor decreases with the installation of non resistive loads such as induction motors, Transformers.

Lighting ballasts and electronic equipments. Power factors can be corrected by using capacitors. These are rated in electrical units called VAR or KVAR.One VAR is equivalent to one volt of reactive power. VAR then are units of measurement for indicating just how much reactive power the capacitor will supply.

1010

As reactive power is usually measured in thousands the

letter K is used for thousand. the capacitor KVAR rating then shows how much reactive power the capacitor will supply. Each unit of the capacitor's KVAR will decrease the inductive reactive power demand.

1111

POWER FACTOR CORRECTIONPOWER FACTOR CORRECTION

Most loads on an electrical distribution system fall into one Most loads on an electrical distribution system fall into one of three categories; resistive, inductive or capacitive. In of three categories; resistive, inductive or capacitive. In most plant, the most common is likely to be inductive. most plant, the most common is likely to be inductive. Typical examples of this include transformers, fluorescent Typical examples of this include transformers, fluorescent lighting and AC induction motors. Most inductive loads lighting and AC induction motors. Most inductive loads use a conductive coil winding to produce an use a conductive coil winding to produce an electromagnetic field, allowing the motor to function.electromagnetic field, allowing the motor to function.

1212

All inductive loads require two kinds of power to operate:All inductive loads require two kinds of power to operate: Active powerActive power (KW) - to produce the motive force (KW) - to produce the motive force Reactive powerReactive power (KVAR) - to energize the magnetic field (KVAR) - to energize the magnetic field The operating power from the distribution system is The operating power from the distribution system is

composed of both active (working) and reactive (non-composed of both active (working) and reactive (non-working) elements. The active power does useful work in working) elements. The active power does useful work in driving the motor whereas the reactive power only driving the motor whereas the reactive power only provides the magnetic field.provides the magnetic field.

1313

POWER FACTOR CORRECTIONPOWER FACTOR CORRECTION

The amount of Power Capacitor KVAR required to correctThe amount of Power Capacitor KVAR required to correct A system to a desired Power Factor level is the difference A system to a desired Power Factor level is the difference

between the amount of KVAR in the uncorrected system between the amount of KVAR in the uncorrected system and the amount of desired KVAR in the corrected system. and the amount of desired KVAR in the corrected system. TheThe most efficient location for power factor capacitors is most efficient location for power factor capacitors is at the load. Capacitors work from the point of installation at the load. Capacitors work from the point of installation back to the generating source. Individual motor correction back to the generating source. Individual motor correction is not always practical, sometimes it is more practical to is not always practical, sometimes it is more practical to connect larger capacitors on the distribution bus or install connect larger capacitors on the distribution bus or install an automatic system at the incoming service along with an automatic system at the incoming service along with fixed capacitors at the load. fixed capacitors at the load.

1414

KVAR CORRECTIONKVAR CORRECTION

Capacitive Power Factor correction (PFC) is applied to

electric circuits as a means of minimising the inductive component of the current and thereby reducing the losses in the supply. The introduction of Power Factor Correction capacitors is a widely recognised method of reducing an electrical load, thus minimising wasted energy and hence improving the efficiency of a plant and reducing the electricity bill.

1515

It is not usually necessary to reach unity, i.e. Power Factor 1, since most supply companies are happy with a PF of 0.95 to 0.98.By installing suitably sized switched capacitors into the circuit, the Power Factor is improved and the value becomes nearer to 1 thus minimising wasted energy and improving the efficiency of a plant or power factor can be increased by synchronous motor or Synchronous generators.

1616

POWER FACTOR CORRECTION POWER FACTOR CORRECTION METHODSMETHODS

Static Var Compensator(SVC)Static Var Compensator(SVC)

Fixed CapcitorsFixed Capcitors

Switch CapacitorsSwitch Capacitors

Synchronous CondensorsSynchronous Condensors

Static Synchronous Compensator (STATCOM)Static Synchronous Compensator (STATCOM)

Modulated power filter capacitor compensatorModulated power filter capacitor compensator

1717

STATIC VAR COMPENSATORSTATIC VAR COMPENSATOR(SVC)(SVC)

The Static Var Compensator (SVC) is a shunt device of the Flexible AC Transmission Systems (FACTS) family using power electronics to control power flow and improve transient stability on power grids [1]. The SVC regulates voltage at its terminals by controlling the amount of reactive power injected into or absorbed from the power system. When system voltage is low, the SVC generates reactive power (SVC capacitive). When system voltage is high, it absorbs reactive power (SVC inductive).

1818

The variation of reactive power is performed by switching three-phase capacitor banks and inductor banks connected on the secondary side of a coupling transformer. Each capacitor bank is switched on and off by three SCR-Thyristor switches (Thyristor- Switched Capacitor or TSC). Reactors are either switched on-off (Thyristor Switched Reactor or TSR) or phase-controlled (Thyristor Controlled Reactor or TCR).

1919

A rapidly operating Static Var Compensator (SVC) can continuously provide the reactive power required to control dynamic voltage swings under various system conditions and thereby improve the power system transmission and distribution performance.

Installing an SVC at one or more suitable points in the network will increase transfer capability through enhanced voltage stability, while maintaining a smooth voltage profile under different network conditions. In

addition, an SVC can mitigate active power oscillations through voltage amplitude modulation

2020

FIXED CAPACITORFIXED CAPACITOR

where the load does not change or where the capacitor is switched with the load, such as the load side of a Ideally suited for power factor correction in applications motor contactor. It is suitable for locations using induction motors, like food processing plants, or where small multiple loads require reactive power

compensation. Each Fixed Capacitor Bank is designed for high reliability and long life. These products are designed for applications that do not contain harmonic generating

2121

SWITCHED CAPACITORSWITCHED CAPACITOR

It is suited for centralized power factor correction in applications where plant loading is constantly changing, resulting in the need for varying amounts of reactive power. An advanced microprocessor-based reactive power controller measures plant power factor via a single remote current transformer (included), and switches capacitor modules in and out of service to maintain a user-selected target power factor. Typically

applied at service entrance or near fluctuating loads.  

2222

SYNCHRONOUS CONDENSER

Synchronous condenser is a salient pole synchronous Synchronous condenser is a salient pole synchronous generator without prime mover. Synchronous condenser generator without prime mover. Synchronous condenser stabilizes power system voltage by supplying reactive stabilizes power system voltage by supplying reactive power to the power system and Use for power factor power to the power system and Use for power factor correction. It is more economical than capacitors.correction. It is more economical than capacitors.

2323

SYNCHRONOUS CONDENSER

2424

STATIC SYNCHRONOUS COMPENSTOR(STATCOM)

The Static Synchronous Compensator (STATCOM) is a shunt device of the Flexible AC Transmission Systems (FACTS) family using power electronics to control power flow and improve transient stability on power grids [1]. The STATCOM regulates voltage at its terminal by controlling the amount of reactive power injected into or absorbed from the power system. When system voltage is low, the STATCOM generates reactive power (STATCOM capacitive).

2525

When system voltage is high, it absorbs reactive power (STATCOM inductive).Similarly to the SVC the STATCOM can provide instantaneous and continuously variable reactive power in response to grid voltage transients enhancing the grid voltage stability

2626

Installing a STATCOM at one or more suitable points in the network will increase the grid transfer capability through enhanced voltage stability, while maintaining a smooth voltage profile under different network conditions. The STATCOM provides additional versatility in terms of power quality improvement capabilities

2727

DETERMINING CAPACITOR VALUE

ExampleExamplePower Factor1=74%Power Factor1=74%Actual Power=594 kwActual Power=594 kwInterested to boost up=97% ,Power Factor2=97%Interested to boost up=97% ,Power Factor2=97%Power Factor=KW/KVAPower Factor=KW/KVACosCos = kW / kVA = kW / kVA = Cos-1 (PF1)= Cos-1 (PF1) = Cos-1 (74%) =42.27 o= Cos-1 (74%) =42.27 o

2828

The reactive power was about:The reactive power was about:TanTan = kVAr / kW = kVAr / kWkVAr = kW x tankVAr = kW x tankVAr = 594 kW x tan (42.27) = 540 kVArkVAr = 594 kW x tan (42.27) = 540 kVArIf the power factor were increased to 97%, the reactive If the power factor were increased to 97%, the reactive power would be about:power would be about:CosCos = kW / kVA = kW / kVA = Cos-1 (PF2)= Cos-1 (PF2) = Cos-1 (97%) = 14.07 o= Cos-1 (97%) = 14.07 okVAr = kW x tankVAr = kW x tan kVAr = 594 kW x tan (14.07) = 149 kVArkVAr = 594 kW x tan (14.07) = 149 kVAr

2929

Thus, the amount of capacitance required to boost Thus, the amount of capacitance required to boost power factor from 74% to 97% :power factor from 74% to 97% :540 kVAr – 149 kVAr = 391 kVAr540 kVAr – 149 kVAr = 391 kVArSo I recommended 400kvarSo I recommended 400kvar

3030

POWER CAPACITORSPOWER CAPACITORSPower Factor correction on site with Power Factor correction on site with

Pole CapPole Cap

3131

POWER FACTOR MEASUREMENTPOWER FACTOR MEASUREMENT

Power factor can measure by using power factor meterPower factor can measure by using power factor meter which is well known in power industry.which is well known in power industry. Power factor can also be calculated by installing watt Power factor can also be calculated by installing watt

meter along with the Ampere meter and volt meter by meter along with the Ampere meter and volt meter by using the power factor basic formula.using the power factor basic formula.

Power factor=Actual Power/ Apparent powerPower factor=Actual Power/ Apparent power

3232

POWER FACTOR MEASUREMENTPOWER FACTOR MEASUREMENT

3333

ADVANTAGES OF POWER FACTOR CORRECTION

3434

Increase equipment life Save on utility costEnhance equipment operation by improving voltageImprove energy efficiency

3535

Reduction in size of transformers, cables and switchgear Reduction in size of transformers, cables and switchgear in new installations.in new installations.Delay costly upgrades.Delay costly upgrades.Less total plant KVA for the same KW working power. Less total plant KVA for the same KW working power. Improved voltage regulation due to reduced line voltage Improved voltage regulation due to reduced line voltage drop. drop.

3636

POWER COST REDUCTION

Utility companies in many areas include a penalty charge in the electrical rate for low power factor. The installation of power factor capacitors on the user's electrical distribution system eliminates the necessity of paying premium rates to the utility company for poor power factor. .

3737

The savings the utility company derives in reduced

generation, transmission and distribution costs are passed on to the user in the form of lower electrical charges.  Three of the more common ways a utility charges a user for poor power factor are based on

3838

KW demand with a trigger point typically between 85% KW demand with a trigger point typically between 85% and 95% and 95% KVA demand KVA demand KVAR demand KVAR demand When the utility uses either KVA demand or KVAR When the utility uses either KVA demand or KVAR demand as the basis for its penalty structure, all users demand as the basis for its penalty structure, all users pay a penalty, but those with high power factor pay a pay a penalty, but those with high power factor pay a much lower penalty or none at all.much lower penalty or none at all.

3939

SYSTEM CAPACITY INCREASESYSTEM CAPACITY INCREASE By adding capacitors to the system, the power factor is By adding capacitors to the system, the power factor is

improved and the KW capacity of the system is improved and the KW capacity of the system is increased. For example, a 1,000 KVA transformer with a increased. For example, a 1,000 KVA transformer with a 70% power factor provides 700 KW of power to the main 70% power factor provides 700 KW of power to the main bus. With the installation of capacitors so that the power bus. With the installation of capacitors so that the power factor is improved, say, to 90%, the KW capacity of the factor is improved, say, to 90%, the KW capacity of the system is increased to 900 KW. When a system power system is increased to 900 KW. When a system power factor is improved, the amount of reactive current flowingfactor is improved, the amount of reactive current flowing

Is lowered thus reducing transformer and distribution Is lowered thus reducing transformer and distribution circuit loads, and releasing system capacity.circuit loads, and releasing system capacity.

4040

VOLTAGE IMPROVEMENT AND POWER VOLTAGE IMPROVEMENT AND POWER LOSS REDUCTIONLOSS REDUCTION

System losses are also reduced through power factor System losses are also reduced through power factor correction by reducing the total current and power in the correction by reducing the total current and power in the system. A 20% reduction in current will yield a 36% system. A 20% reduction in current will yield a 36% reduction in distribution system losses. In this situation, reduction in distribution system losses. In this situation, an energy savings of as much as 50% will be realized an energy savings of as much as 50% will be realized with the installation of power factor capacitors. with the installation of power factor capacitors.

In addition, power factor capacitors decrease the In addition, power factor capacitors decrease the distribution system voltage drops and fluctuationsdistribution system voltage drops and fluctuations..

4141

DISADVANTAGES OF LOW POWER DISADVANTAGES OF LOW POWER FACTORFACTOR

Increases heating losses in the transformers and Increases heating losses in the transformers and distribution equipments.distribution equipments.Reduce plant life.Reduce plant life.Unstabilise voltage levels.Unstabilise voltage levels.Increase power losses.Increase power losses.Upgrade costly equipments.Upgrade costly equipments.Decrease energy efficiency.Decrease energy efficiency.Increase electricity costs by paying power factor Increase electricity costs by paying power factor surcharges.surcharges.

4242

CONCLUSION

By observing all aspects of the power factor it is clear that power factor is the most significant part for the utility Company as well as for the consumer. Utility company rid of from the power losses while the consumer free from low power factor penalty charges.

By installing suitably sized power capacitors into the circuit the Power Factor is improved and the value the Power Factor is improved and the value becomes nearer to 1 thus minimising line losses and becomes nearer to 1 thus minimising line losses and improving the efficiency of a plant. improving the efficiency of a plant.

4343

REFERENCESREFERENCES

Electrical Power System Design and Analysis Electrical Power System Design and Analysis by M.E.EI-Hawary.by M.E.EI-Hawary.

Power System Operations Power System Operations by Robert H Miller.by Robert H Miller.

IEEE papersIEEE papers www.ABB.comwww.ABB.comBC Hydro (BC Hydro (www.bchydro.cawww.bchydro.ca))