2
Power and Voltage-Switching Unit (PVSU) POWER MANAGEMENT UNIT_ Features The PVSU combines and modernizes the three most common military ground-mobile power handling LRUs (PDU, PSU, & VSU) The PVSU utilizes state-of-the-art, self-protected, BIT capable, “Smart Power” switching hybrids and interface circuitry The PVSU unites an intuitive operator interface with military HFE designed displays and controls The PVSU provides full BIT/BITE, diagnostics, and fault isolation The PVSU is the easily integrated, full military environment qualified power handling solution for legacy Platform upgrades and new platform designs Description The power distribution portion current limits, filters and distributes the platform’s prime power source to the platform’s DC power grid Power system faults are displayed and communicated on the CAN Bus Electronic “circuit-breakers” can be reset locally or remotely via the CAN Bus The power select portion allows the user to switch between various platform and external power sources NATO (28V) Receptacle, Auxiliary Power Unit, Shore Power (AC), Inverter outputs, etc. The voltage switching portion displays the State of Health (SoH) for the battery bank(s), the ac input/inverter outputs, and provides optional Battery Bank switching for isolation, load switching, battle-override, and emergency starting functions.

Power and Voltage-Switching Unit (PVSU) - Moog Inc. · Voltage-Switching Unit (PVSU) POWER MANAGEMENT UNIT_ Features ... self-protected, BIT capable, “Smart Power” switching hybrids

Embed Size (px)

Citation preview

Power andVoltage-Switching Unit (PVSU)

POWERMANAGEMENT UNIT_

Features• The PVSU combines and modernizes the three most common military ground-mobile power handling

LRUs (PDU, PSU, & VSU)• The PVSU utilizes state-of-the-art, self-protected, BIT capable, “Smart Power” switching hybrids and interface circuitry• The PVSU unites an intuitive operator interface with military HFE designed displays and controls• The PVSU provides full BIT/BITE, diagnostics, and fault isolation• The PVSU is the easily integrated, full military environment qualified power handling solution for legacy Platform

upgrades and new platform designs

DescriptionThe power distribution portion current limits, filters and distributes the platform’s prime power source to the platform’s DC power grid• Power system faults are displayed and communicated on the CAN Bus• Electronic “circuit-breakers” can be reset locally or remotely via the CAN Bus

The power select portion allows the user to switch between various platform and external power sources• NATO (28V) Receptacle, Auxiliary Power Unit, Shore Power (AC), Inverter outputs, etc.

The voltage switching portion displays the State of Health (SoH) for the battery bank(s), the ac input/inverter outputs, and provides optional Battery Bank switching for isolation, load switching, battle-override, and emergency starting functions.

Form 500-722 1010

East Aurora, NY 14052 USA+1.716.652.2000 www.moog.com

© 2010 Moog, Inc . A l l r i gh ts reser ved .

PVSU_POWER AND VOLTAGE SWITCHING UNIT_

Specifications

I/O ConnectorsM38999, Series III, signal/power

M5015, high power

Front panel aux connectors2, 12 Vdc, 10A2, 28 Vdc, 10A

1, 120 Vac, 15A, GFI

Aluminum enclosure and coverMIL-C-5541/53072 conversion/CARC coatings

Fully sealed, NBC decontaminationDC input voltage 28V per MIL-STD-1275C and MIL-STD-704F

Transient voltages (single fault)100V surge, 250V spikes

Controlled to <= 51VReverse voltage protected

EMI/EMC/E3

MIL-STD-461E: CE102, CS101, CS114, CS115, CS116, RE102, RS103MIL-STD-464: Lightening, electrical bonding and grounding, upgradeable for TEMPEST

Nuclear weapons INR/EMP hardening an optionEnvironmental (MIL-STD-810F)

Temperture: Method 501.4P-I, storage, Tst = -51˚ C to 85˚ C

P-II, Operation, Top = -40˚ C to 71˚ CVibration: Method 514.5 Cat-24, Minimum integrity test vehicleShock: Method 516.5-8 40 g, 7.5msHumidity: Method 507.4 5 cycles, 95% RHSalt Fog: Method 509.4 5%, 48 hours

Sand and Dust: Method 510.4 P-I and P-II, 6 hoursFungus: Method 508.5 28 days

Altitude: Method 500.4P-I and P-II, 6 hours

P-II, operation P-III, rapid decompression

Immersion: Method 512.4 P-II, 1m, 1 hourCleaning 10 gpm, .25” ø nozzle, 1 ft ┴ to LRU

Mechanical dataEnvelope 11.5” x 20.0” x 7.0”Weight < 30 lbs (14 kg)

PVSU Specifications20 Electronic Circuit-Breakers (ECB)• Configurable 5A to 50A• “Reset” from Front Panel or via CAN Bus• Remote Breaker Assembly provides 20 additional

PVSU controlled ECBs

Displays• Two, Battery State of Health• Power Fault for ECB status/control• AC & DC Voltage• Two, Inverter Power Status• Display test & brightness functions

Comprehensive diagnostics & BIT/BITE• PBIT, CBIT, & IBIT (if required)• Status reported on serial bus (CAN)

Communication• CAN Bus• RS232• GbE Wire/Fiber, standard option• Easily upgraded for other Buses