1
R PORTABLE SMART Air Quality METER FEATURES : Long life non-dispersive infrared Co2 sensor, self-calibration. Accuracy:+50ppm+5% of rdg German precision electrochemical CO .Accuracy:+5% of rdg or +10ppm German stable and nice performance O2 sensor. Accuracy:+1% with 0.1 resolution o o Precision free maintenance capacitor RH% sensor. Accuracy:+3% (At 25 C+3 C) NIST traceable Formaldehyde meter UK sensor. Accuracy: Meets NOISH’s acceptance criterion within +25% of true value at 95% confidence level. Japanese made electrochemical combustible gas sensor (Methane, Propane) Precision pressure sensor measurement (98199.98599 models only) Low dB mini bumper(fan) quick to draw in ambient air or gas for quick response USB interface for datalogging models (98598.98599 only) stores up to 32,000 points with user friendly free software( 5 start to record modes incl. real time logging) Supplied with soft tube and built-in electric fan in probe for gas in and out from chamber or air duct or the place hard to reach or avoid sensor condensation Designed with dual TI micro-processors(MCU) smart communicate meter and probe Multi-display LCD size 44x33mm, simultaneously display main parameters,Temp.RH% High or low alarm threshold setting with beep sound. LEDs (red and green) are built. HOLD function and APO (Auto power off ) in 15 minutes if no use Maximum or Minimum: Record since powered on , recall to check Powered by rechargeable 3.7V lithium Ion battery, may recharge battery with adaptor. Feature bright backlight for operation in dark area Each sensor probe built-in Temp.RH sensor, may calculate dew point, Wet bulb Temp. Supplied with : Meter, probe, manual, Shoulder pouch, USB cable(logger model), Software CD(logger models),soft tube 30cm,adaptor. , 98198 98199 98598 98599 98198-kit (incl. 5 sensor probes) or 98199-kit (Incl. pressure measurement) 98598-kit (incl .5 sensor probes) or 98599-kit (Incl. pressure measurement) MIC Smart Combo air quality meter / datalogger incl. on line & off line Smart Air quality meter integrates multi-sensor measurement =98198+ Pressure measurement (300~1100hpa/mbar) =98198+ off line & realt ime datalogger function ( Store up to 32,000 points ) =98598+ Pressure measurement (300~1100hpa/mbar) P/N Description Range: Sensor probe seperately: 98198C Meter w/CO probe CO: 0~999 ppm . Temp:0.0~50.0C.RH%:0.0~99.9% 98198PC CO probe 98198D Meter w/CO2 probe CO2: 0~9999 ppm Temp:0.0~50.0C.RH%:0.0~99.9% 98198PD CO2 probe 98198O Meter w/O2 probe O2: 0~30% Temp:0.0~50.0C.RH%:0.0~99.9% 98198PO O2 probe 98198H Meter w/HCHO probe HCHO: 0.00~5.00 ppm Temp:0.0~50.0C.RH%:0.0~99.9% 98198PH HCHO probe 98198M Meter w/Combustible gas probe LED:0~25%(methane,Propane) Temp:0.0~50.0C.RH%:0.0~99.9% 98198PM Combustible gas probe ( Exampleof98198. 98598series) ( Exampleof98199. 98599series)

PORTABLE SMART Air Quality METER - … MIC catalogue/New...Designed with dual TI micro-processors(MCU) smart communicate meter and probe Multi-display LCD size 44x33mm, simultaneously

Embed Size (px)

Citation preview

R

PORTABLE SMART Air Quality METER

FEATURES :Long life non-dispersive infrared Co2 sensor, self-calibration. Accuracy:+50ppm+5% of rdg

German precision electrochemical CO .Accuracy:+5% of rdg or +10ppm

German stable and nice performance O2 sensor. Accuracy:+1% with 0.1 resolutiono oPrecision free maintenance capacitor RH% sensor. Accuracy:+3% (At 25 C+3 C)

NIST traceable Formaldehyde meter UK sensor. Accuracy: Meets NOISH’s acceptance criterion within +25% of true value at 95% confidence level.Japanese made electrochemical combustible gas sensor (Methane, Propane)Precision pressure sensor measurement (98199.98599 models only)

Low dB mini bumper(fan) quick to draw in ambient air or gas for quick responseUSB interface for datalogging models (98598.98599 only) stores up to 32,000 points with user friendly free software( 5 start to record modes incl. real time logging)Supplied with soft tube and built-in electric fan in probe for gas in and out from chamberor air duct or the place hard to reach or avoid sensor condensation Designed with dual TI micro-processors(MCU) smart communicate meter and probe Multi-display LCD size 44x33mm, simultaneously display main parameters,Temp.RH%High or low alarm threshold setting with beep sound. LEDs (red and green) are built.HOLD function and APO (Auto power off ) in 15 minutes if no use Maximum or Minimum: Record since powered on , recall to check Powered by rechargeable 3.7V lithium Ion battery, may recharge battery with adaptor. Feature bright backlight for operation in dark area Each sensor probe built-in Temp.RH sensor, may calculate dew point, Wet bulb Temp.

Supplied with : Meter, probe, manual, Shoulder pouch, USB cable(logger model), Software CD(logger models),soft tube 30cm,adaptor. ,

98198

98199

98598

98599

98198-kit (incl. 5 sensor probes) or 98199-kit (Incl. pressure measurement)

98598-kit (incl .5 sensor probes) or 98599-kit (Incl. pressure measurement)

MIC Smart Combo air quality meter / datalogger incl. on line & off line

Smart Air quality meter integrates multi-sensor measurement

=98198+ Pressure measurement (300~1100hpa/mbar)

=98198+ off line & realt ime datalogger function ( Store up to 32,000 points )

=98598+ Pressure measurement (300~1100hpa/mbar)

P/N Description Range: Sensor probe seperately:

98198CMeter w/CO

probe

CO: 0~999 ppm .

Temp:0.0~50.0C.RH%:0.0~99.9%98198PC CO probe

98198DMeter w/CO2

probe

CO2: 0~9999 ppm

Temp:0.0~50.0C.RH%:0.0~99.9%98198PD CO2 probe

98198OMeter w/O2

probe

O2: 0~30%

Temp:0.0~50.0C.RH%:0.0~99.9%98198PO O2 probe

98198HMeter w/HCHO

probe

HCHO: 0.00~5.00 ppm

Temp:0.0~50.0C.RH%:0.0~99.9%98198PH HCHO probe

98198M

Meter

w/Combustible

gas probe

LED:0~25%(methane,Propane)

Temp:0.0~50.0C.RH%:0.0~99.9%98198PM

Combustible

gas probe

(Example�of�98198.98598�series)