33
Version 8.5 | December 2014 | 3275-69957-004/B Hardware Guide RealPresence ® Collaboration Server (RMX ® ) 1800

Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Version 8.5 | December 2014 | 3275-69957-004/B

Hardware Guide

RealPresence® Collaboration Server (RMX®) 1800

Page 2: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

2

Copyright© 2014, Polycom, Inc. All rights reserved. No part of this document may be reproduced, translated into another language or format, or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Polycom, Inc.

6001 America Center DriveSan Jose, CA 95002USA

Trademarks Polycom®, the Polycom logo and the names and marks associated with Polycom products are trademarks and/or service marks of Polycom, Inc. and are registered and/or common law marks in the United States and various other countries.

All other trademarks are property of their respective owners. No portion hereof may be reproduced or transmitted in any form or by any means, for any purpose other than the recipient's personal use, without the express written permission of Polycom.

End User License Agreement By installing, copying, or otherwise using this product, you acknowledge that you have read, understand and agree to be bound by the terms and conditions of the End User License Agreement for this product. The EULA for this product is available on the Polycom Support page for the product.

Patent Information The accompanying product may be protected by one or more U.S. and foreign patents and/or pending patent applications held by Polycom, Inc.

Open Source Software Used in this Product This product may contain open source software. You may receive the open source software from Polycom up to three (3) years after the distribution date of the applicable product or software at a charge not greater than the cost to Polycom of shipping or distributing the software to you. To receive software information, as well as the open source software code used in this product, contact Polycom by email at [email protected].

Disclaimer While Polycom uses reasonable efforts to include accurate and up-to-date information in this document, Polycom makes no warranties or representations as to its accuracy. Polycom assumes no liability or responsibility for any typographical or other errors or omissions in the content of this document.

Limitation of Liability Polycom and/or its respective suppliers make no representations about the suitability of the information contained in this document for any purpose. Information is provided "as is" without warranty of any kind and is subject to change without notice. The entire risk arising out of its use remains with the recipient. In no event shall Polycom and/or its respective suppliers be liable for any direct, consequential, incidental, special, punitive or other damages whatsoever (including without limitation, damages for loss of business profits, business interruption, or loss of business information), even if Polycom has been advised of the possibility of such damages.

Customer Feedback We are striving to improve our documentation quality and we appreciate your feedback. Email your opinions and comments to [email protected].

Polycom Support Visit the Polycom Support Center for End User License Agreements, software downloads, product documents, product licenses, troubleshooting tips, service requests, and more.

Page 3: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 3

Environmental

This product is compliant with the requirements of the recast RoHS Directive 2011/65/EU. Information can be obtained from Polycom Ltd, 270 Bath Road, Slough, Berkshire, SL1 4DX, UK or via: [email protected]

Information on recycling can be found at: www.polycom.com/WEEE

Disposal of this equipment should be carried out in accordance with local environmental guidelines and regulations for waste. For further information please contact: [email protected]

Batteries

Below is a listing of batteries that could be present in the product:

Description:Internal CMOS battery

Type:CR2032 Lithium Coin Cell

Weight:3.3g

Batteries used in this product are in compliance with EU Battery Directive 2006/66/EC.

Batteries in this product are not based on mercury, lead or cadmium technologies.

Batteries in this product are not intended to be replaced or removed by the user

Additional information on the safe use and recycling of batteries can be found at: www.polycom.com/batteries

Taiwan BSMI EMC statement

Worldwide EMC statement

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Page 4: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 4

Optional ISDN interface card

If the above is fitted to the system then the following statements also apply;

United States Federal Communication Commission (FCC)

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the ISDN card itself is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.

The following USOC, FIC and SOC codes are applicable to this equipment;

USOC Jacks: RJ48S

Service Order Code: 6.0N

Facility Interface Code: 04DU9.DN, 04DU9.BN, 04DU9.1KN, 04DU9.1SN

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.

If trouble is experienced with this equipment, for repair or warranty information, please contact Polycom Inc in the U.S.A. 1-888-248-8294. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.

Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

Page 5: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Table of Content

Polycom, Inc. 5

Table of Content

Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Main Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Conferencing Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Resource Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Resource Capacities in Non-Mixed Conferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Resource Capacities in Mixed Conferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

VSW Maximum Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

ISDN Resource Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Prepare for Installing RealPresence Collaboration Server (RMX) 1800 . . . . . . . 17RealPresence Collaboration Server (RMX) 1800 Site Requirements . . . . . . . . . . . . . . . . . . . 17

Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Shelf Mount Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Installation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Unpack the RealPresence Collaboration Server (RMX) 1800 . . . . . . . . . . . . . . . . . . . . . . . . . 18

Install the RealPresence Collaboration Server (RMX) 1800 . . . . . . . . . . . . . . . . 20Mount the RealPresence Collaboration Server (RMX) 1800 on a Shelf . . . . . . . . . . . . . . . . . 20

Connect the RealPresence Collaboration Server (RMX) 1800 to a Power Source . . . . . . . . . 21

Connect Cables to the RealPresence Collaboration Server (RMX) 1800 . . . . . . . . . . . . . . . . 21

First-time Power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

RealPresence Collaboration Server (RMX) 1800 Front Panel . . . . . . . . . . . . . . . . . . . . . 23

RealPresence Collaboration Server (RMX) 1800 Rear Panel . . . . . . . . . . . . . . . . . . . . . 24

Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Remarques importantes concernant la sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

USA and Canadian Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Russia Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . 30

Customs Union (Russia, Belarus, Kazakhstan) Regulatory Information . . . . . . . . . . . . . . 30

European Economic Area (EEA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Chinese . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Page 6: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Table of Content

Polycom, Inc. 6

Korea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Page 7: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 7

Hardware Description

This Hardware Guide provides information on the Polycom® RealPresence® Collaboration Server (RMX®) 1800 and its components.

Main FeaturesThe Polycom RealPresence Collaboration Server (RMX) 1800 offers the following features:

Linux®

Standard network ports (H.323, SIP, LAN and ISDN)

New hardware codec technologies

Up to 1080p60 high definition video conferencing

Telecommunication grade high availability and on-line upgrading

Easy integration of conference elements into external network management

Enhanced Continuous Presence (multi-image video)

IVR (Interactive Voice Response) module

Both H.264 SVC endpoints-only conferencing, and AVC-SVC mixed conferencing

Hot backup to offer high availability and a rapid recovery solution

Note: Illustrations in this book

Illustrations in this book are for your reference only and may not accurately depict the actual system.

Page 8: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 8

System SpecificationsThe following table lists system specifications of the RealPresence Collaboration Server (RMX) 1800 system.

System Specifications

Physical

Height 2U (8.9 cm.)

Width 17.36 '' (44.1 cm.)

Depth 19.13 '' (48.6 cm.)

Weight Up to 14.5 Kg (31.97 lbs)

Media Protocols

Audio SAC, G.711, G.719, G.722.x, G.729A, Siren 14, Siren 22 (in mono or stereo) and Siren LPR

Video H.261, H.263, H.263+, H.264, H.264 High Profile, H.264 SVC

Network Ports

Signaling H.323, SIP, ISDN

LAN LAN 1, LAN 2

ISDN PRI1, PRI 2, PRI 3, PRI 4, each can work as either an E1 port or T1 port

Power Supply

AC Input/ Range, Power output Voltage range: 100-240 VAC 50-60 Hz

Current: 10-3.5 AMP

Maximum power output: 740 w

Power Consumption

AC Maximum Power consumption 350 w

Environment

Operating temperature 10° to 35°C (50° to 95°F)

Storage temperature -40° to 70°C (-40° to 158° F)

Relative humidity 20% to 90% non-condensing

Operating altitude Up to 5 KM (16404 Ft.)

Operating ESD 4 KV

Page 9: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 9

Conferencing CapacitiesThe following table summarizes the different conferencing capacities of RealPresence Collaboration Server (RMX) 1800.

System Functions and Capacities of RMX 1800 Series

System Functions Number

Maximum number of Video participants in a CP conference 200

Maximum number of Video participants in a SVC only conference 300

Maximum number of Audio-only participants in a conference 300

Maximum number of Audio calls per second 5

Maximum number of Video calls per second 2

Maximum number of conferences 200

Maximum number of Meeting Rooms 1000

Maximum number of Entry Queues 40

Maximum number of Profiles 80

Maximum number of Conference Templates 400

Maximum number of SIP Factories 40

Maximum number of IP Services 2

Maximum number of ISDN Services 2

Maximum number of IVR Services 80

Maximum number of Recording Links 20 (Default)

Maximum number of IVR Video Slides 150

Maximum number of CDR Files 2000

Maximum number of Fault Files 1000

Number of Participant alerts No limitation

Maximum number of concurrent RealPresence Collaboration Server 1800 Web Client connections to the MCU

20

Maximum number Address Book entries 4000

Maximum number of Users 100

Maximum number of Reservations (internal scheduler) 2000

Page 10: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 10

Resource CapacitiesThis section provides information of resource capacities in non-mixed conference and mixed conference, VSW maximum capacities at different line rates. This section also provides information of ISDN resource capacities on RealPresence Collaboration Server (RMX) 1800 with three DSP cards equipped.

Resource Capacities in Non-Mixed ConferencesThe following table lists the system capacities for each license in non-mixed conferences when the system has three DSP cards.

Licensed Capacity for Systems with Three DSP Cards, in Non-mixed Conferences

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF Audio

SVC720p

SVC1080p

5 1 2 5 10 10 60 15 15

10 2 5 10 20 20 120 30 30

15 3 7 15 30 30 180 45 45

20 5 10 20 40 40 240 60 60

25 6 12 25 50 50 300 75 75

30 7 15 30 60 60 300 90 90

35 8 17 35 70 70 300 105 105

40 10 20 40 80 80 300 120 120

45 11 22 45 90 90 300 135 135

50 12 25 50 100 100 300 150 150

55 13 27 55 110 110 300 165 150

60 15 30 60 120 120 300 180 150

65 16 32 65 130 130 300 195 150

70 17 35 70 140 140 300 210 150

75 18 37 75 150 150 300 225 150

80 20 40 80 160 160 300 240 150

85 21 42 85 170 170 300 255 150

90 22 45 90 180 180 300 270 150

95 23 47 95 190 190 300 285 150

100 25 50 100 200 200 300 300 150

Page 11: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 11

The following table lists port ratios for each license in non-mixed conferences when the system has three DSP cards.

Port Ratios for Systems with Three DSP Cards, in Non-mixed Conferences

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF

Audio/SVC

SVC 720p

SVC 1080p

5 0.20 0.40 1.00 2.00 2.00 12.00 3.00 3.00

10 0.20 0.50 1.00 2.00 2.00 12.00 3.00 3.00

15 0.20 0.47 1.00 2.00 2.00 12.00 3.00 3.00

20 0.25 0.50 1.00 2.00 2.00 12.00 3.00 3.00

25 0.24 0.48 1.00 2.00 2.00 12.00 3.00 3.00

30 0.23 0.50 1.00 2.00 2.00 10.00 3.00 3.00

35 0.23 0.49 1.00 2.00 2.00 8.57 3.00 3.00

40 0.25 0.50 1.00 2.00 2.00 7.50 3.00 3.00

45 0.24 0.49 1.00 2.00 2.00 6.67 3.00 3.00

50 0.24 0.50 1.00 2.00 2.00 6.00 3.00 3.00

55 0.24 0.49 1.00 2.00 2.00 5.45 3.00 2.73

60 0.25 0.50 1.00 2.00 2.00 5.00 3.00 2.50

65 0.25 0.49 1.00 2.00 2.00 4.62 3.00 2.31

70 0.24 0.50 1.00 2.00 2.00 4.29 3.00 2.14

75 0.24 0.49 1.00 2.00 2.00 4.00 3.00 2.00

80 0.25 0.50 1.00 2.00 2.00 3.75 3.00 1.88

85 0.25 0.49 1.00 2.00 2.00 3.53 3.00 1.76

90 0.24 0.50 1.00 2.00 2.00 3.33 3.00 1.67

95 0.24 0.49 1.00 2.00 2.00 3.16 3.00 1.58

100 0.25 0.50 1.00 2.00 2.00 3.00 3.00 1.50

Page 12: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 12

The following table lists the system capacities for each license in non-mixed conferences when the system has one DSP card.

Licensed Capacity for Systems with One DSP Card, in Non-mixed Conferences

The following table lists port ratios for each license in non-mixed conferences when the system has one DSP card.

Port Ratios for Systems with One DSP Card, in Non-mixed Conferences

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF Audio

SVC720p

SVC1080p

5 1 2 5 10 10 60 15 15

10 2 5 10 20 20 120 30 30

15 3 7 15 30 30 180 45 45

20 5 10 20 40 40 240 60 60

25 6 12 25 50 50 300 75 75

30 7 15 30 60 60 300 90 90

35 8 17 35 70 70 300 105 105

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF

Audio/SVC

SVC720p

SVC1080p

5 0.20 0.40 1.00 2.00 2.00 12.00 3.00 3.00

10 0.20 0.50 1.00 2.00 2.00 12.00 3.00 3.00

15 0.20 0.47 1.00 2.00 2.00 12.00 3.00 3.00

20 0.25 0.50 1.00 2.00 2.00 12.00 3.00 3.00

25 0.24 0.48 1.00 2.00 2.00 12.00 3.00 3.00

30 0.23 0.50 1.00 2.00 2.00 10.00 3.00 3.00

35 0.23 0.49 1.00 2.00 2.00 8.57 3.00 3.00

Page 13: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 13

Resource Capacities in Mixed ConferencesThe following table lists the system capacities for each license in mixed conferences when the system has three DSP cards.

Licensed Capacity for Systems with Three DSP Cards, in Mixed Conferences

* up to 360p are decoded from SVC to AVC in mixed conference.

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF Audio

SVC 720p*

SVC 1080p*

5 1 2 3 6 6 60 15 15

10 2 4 6 13 13 120 30 30

15 3 6 10 20 20 180 45 45

20 4 8 13 26 26 200 60 60

25 5 10 16 33 33 200 75 75

30 6 12 20 40 40 200 90 90

35 7 14 23 46 46 200 105 105

40 8 16 26 53 53 200 120 120

45 10 18 30 60 60 200 135 135

50 11 20 33 66 66 200 150 150

55 12 22 36 73 73 200 165 150

60 13 24 40 80 80 200 180 150

65 14 26 43 86 86 200 195 150

70 15 28 46 93 93 200 200 150

75 16 30 50 100 100 200 200 150

80 17 32 53 100 100 200 200 150

85 18 34 56 100 100 200 200 150

90 20 36 60 100 100 200 200 150

95 21 38 63 100 100 200 200 150

100 22 40 66 100 100 200 200 150

Page 14: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 14

The following table lists the port ratios for each license in mixed conferences when the system has three DSP cards.

Port Ratios for Systems with Three DSP Cards, in Mixed Conferences

* up to 360p are decoded from SVC to AVC in mixed conference.

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF Audio

SVC 720p*

SVC 1080p*

5 0.20 0.40 0.60 1.20 1.20 12.00 3.00 3.00

10 0.20 0.40 0.60 1.30 1.30 12.00 3.00 3.00

15 0.20 0.40 0.67 1.33 1.33 12.00 3.00 3.00

20 0.20 0.40 0.65 1.30 1.30 10.00 3.00 3.00

25 0.20 0.40 0.64 1.32 1.32 8.00 3.00 3.00

30 0.20 0.40 0.67 1.33 1.33 6.67 3.00 3.00

35 0.20 0.40 0.66 1.31 1.31 5.71 3.00 3.00

40 0.20 0.40 0.65 1.33 1.33 5.00 3.00 3.00

45 0.22 0.40 0.67 1.33 1.33 4.44 3.00 3.00

50 0.22 0.40 0.66 1.32 1.32 4.00 3.00 3.00

55 0.22 0.40 0.65 1.33 1.33 3.64 3.00 2.73

60 0.22 0.40 0.67 1.33 1.33 3.33 3.00 2.50

65 0.22 0.40 0.66 1.32 1.32 3.08 3.00 2.31

70 0.21 0.40 0.66 1.33 1.33 2.86 2.86 2.14

75 0.21 0.40 0.67 1.33 1.33 2.67 2.67 2.00

80 0.21 0.40 0.66 1.25 1.25 2.50 2.50 1.88

85 0.21 0.40 0.66 1.18 1.18 2.35 2.35 1.76

90 0.22 0.40 0.67 1.11 1.11 2.22 2.22 1.67

95 0.22 0.40 0.66 1.05 1.05 2.11 2.11 1.58

100 0.22 0.40 0.66 1.00 1.00 2.00 2.00 1.50

Page 15: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 15

The following table lists the system capacities for each license in mixed conferences when the system has one DSP card.

Licensed Capacity for Systems with One DSP Card, in Mixed Conferences

* up to 360p are decoded from SVC to AVC in mixed conference.

The following table lists the port ratios for each license in mixed conferences when the system has one DSP card.

Port Ratios for Systems with One DSP Card, in Mixed Conferences

* up to 360p are decoded from SVC to AVC in mixed conference.

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF Audio

SVC 720p *

SVC 1080p*

5 1 2 3 6 6 60 15 15

10 2 4 6 13 13 120 30 30

15 3 6 10 20 20 180 45 45

20 4 8 13 26 26 200 60 60

25 5 10 16 33 33 200 75 75

30 6 12 20 40 40 200 90 90

35 7 14 23 46 46 200 90 90

LicensesAVC 1080p60

AVC 1080p30

AVC HD720p30

AVC SD

AVC CIF Audio

SVC 720p*

SVC 1080p *

5 0.20 0.40 0.60 1.20 1.20 12.00 3.00 3.00

10 0.20 0.40 0.60 1.30 1.30 12.00 3.00 3.00

15 0.20 0.40 0.67 1.33 1.33 12.00 3.00 3.00

20 0.20 0.40 0.65 1.30 1.30 10.00 3.00 3.00

25 0.20 0.40 0.64 1.32 1.32 8.00 3.00 3.00

30 0.20 0.40 0.67 1.33 1.33 6.67 3.00 3.00

35 0.20 0.40 0.66 1.31 1.31 5.71 2.57 2.57

Page 16: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Hardware Description

Polycom, Inc. 16

VSW Maximum CapacitiesThe following table shows the maximum capacities of RealPresence Collaboration Server (RMX) 1800 in different line rates.

VSW Maximum Capacity in Different Line Rate

ISDN Resource CapacitiesThe following table shows the numbers of ISDN-Voice or Video participants through E1 or T1 port in different bit rates.

ISDN Resource Capacities

Line Rates Maximum Capacities

2M 200

4M 150

6M 100

Note: ISDN on RMX 1800 with three DSP cards

The ISDN is available only for RMX 1800 system equipped with three DSP cards.

Bit Rates (Kbps Bonded) System Participants (E1) System Participants (T1) Participant Type

64 120 92 ISDN‐Voice

128 60 44 Video

192 40 28 Video

256 28 20 Video

384 20 12 Video

512 12 8 Video

768 8 4 Video

Page 17: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 17

Prepare for Installing RealPresence Collaboration Server (RMX) 1800

This section describes preparations before installing the RealPresence Collaboration Server (RMX) 1800.

RealPresence Collaboration Server (RMX) 1800 Site RequirementsThis section describes the requirements your site must meet for safe installation and operation of the

system.

Safety RequirementsFor your protection, please read these safety instructions completely before operating the equipment.

Look carefully for potential hazards in your work area: moist floors, ungrounded power cables, frayed power cords, missing safety grounds and so forth.

Locate the main circuit breaker within the room.

Locate the emergency power OFF switch within the room.

Never assume that power is disconnected from a circuit.

Use only the power cord supplied with the system.

The power cord should be connected only to a power outlet that has a protective ground contact.

Ensure that the power cord is easily accessible from the back of the system at all times.

Place the equipment in a well-ventilated area where the vents are free from obstruction.

Do not place heavy objects directly on top of the RealPresence Collaboration Server (RMX) 1800 unit.

Do not use liquids around your equipment.

Shelf Mount Safety PrecautionsThe following precautions should be followed with regards to rack mount safety:

Keep the area around the RealPresence Collaboration Server (RMX) 1800 clean and free of clutter.

Decide on a suitable location for the equipment rack that will hold the RealPresence Collaboration Server (RMX) 1800 unit. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need to place it near a grounded power outlet.

Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.

Page 18: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Prepare for Installing RealPresence Collaboration Server (RMX) 1800

Polycom, Inc. 18

Install the heaviest components on the bottom of the rack first, and then work up.

Allow the power supply units to cool before touching them.

Installation PrecautionsWhen handling electronic components, standard anti-static precautions must be observed:

Wear a grounding strap

Keep components in anti-static bags, when not installed in the RealPresence Collaboration Server (RMX) 1800.

The number of power units (maximum two, default one) varies by your product package.

The following precautions should be followed with regards to installation of the RealPresence Collaboration

Server (RMX) 1800:

Use a regulating uninterruptable power supply (UPS) to protect the RealPresence Collaboration Server (RMX) 1800 from power surges and voltage spikes, and to keep your MCU operating in case of a power failure.

Place the RealPresence Collaboration Server (RMX) 1800 on a hard, flat surface such as a desktop, or mount it on a 19” rack.

The airflow of the RealPresence Collaboration Server (RMX) 1800 is from front to back. Be sure that the areas in the front and rear side of the system are clear for proper ventilation.

Unpack the RealPresence Collaboration Server (RMX) 1800Perform the following steps to unpack and lift the RealPresence Collaboration Server (RMX) 1800.

To unpack the RealPresence Collaboration Server (RMX) 1800:

1 When you receive the RealPresence Collaboration Server (RMX) 1800 packing case, inspect the equipment for damage and verify that the components match the packing slip.

2 Open the top cover of the packing case.

Boxes are placed on the top Stratocell® and contain one AC power cable, two ethernet cables, one USB key, one DB-9 Serial cable and one printed ISDN license.

Make sure that the box contains all the required parts.

Warning: Warranty void if the seal is broken

The RealPresence Collaboration Server (RMX) 1800 is a sealed system, so breaking the seal and

opening the chassis voids the warranty.

Page 19: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Prepare for Installing RealPresence Collaboration Server (RMX) 1800

Polycom, Inc. 19

2

Note: Write down the serial number

Write down the Collaboration Server serial number from the sticker on the back of the unit. It will

be needed for product registration later in the process.

Page 20: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 20

Install the RealPresence Collaboration Server (RMX) 1800

Perform following procedures to install the RealPresence Collaboration Server (RMX) 1800 in your site:

Mount the RealPresence Collaboration Server (RMX) 1800 on a Shelf

Connect the RealPresence Collaboration Server (RMX) 1800 to a Power Source

Connect Cables to the RealPresence Collaboration Server (RMX) 1800

Mount the RealPresence Collaboration Server (RMX) 1800 on a ShelfPerform the following steps to mount the RealPresence Collaboration Server (RMX) 1800 on a shelf.

To mount the system on a shelf:

1 Install the shelf, supplied by the rack manufacturer, in the rack.

2 Mount the RealPresence Collaboration Server (RMX) 1800 on the shelf.

3 Fasten the RealPresence Collaboration Server (RMX) 1800 to the rack with screws through the four holes in front mounting brackets of the RealPresence Collaboration Server (RMX) 1800.

Note: Considerations for installing RealPresence Collaboration Server (RMX) 1800

To maximize conferencing performance, especially in high bit rate call environments, a 1Gb connection is recommended for RealPresence Collaboration Server (RMX) 1800.

The equipment must be installed by a trained service person.

Page 21: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Install the RealPresence Collaboration Server (RMX) 1800

Polycom, Inc. 21

Connect the RealPresence Collaboration Server (RMX) 1800 to a Power SourceThe following restrictions apply to the conductors and connectors used to ground the unit when it is rack-mounted:

Bare conductors, must be coated with an appropriate antioxidant compound before crimp connections are made. Tinned, solder-plated or silver-plated connectors do not have to be prepared in this manner.

The same bolt assemblies should not secure multiple connectors.

Listed fastening hardware must be compatible with the materials being joined and must prevent loosening, deterioration and electrochemical corrosion of the hardware and joint materials.

To connect RealPresence Collaboration Server (RMX) 1800 to AC power:r

» Insert the power cable into the power connector on the rear panel of the RealPresence Collaboration Server (RMX) 1800 system.

Connect Cables to the RealPresence Collaboration Server (RMX) 1800This section outlines the way to connect the cables to the RealPresence Collaboration Server (RMX) 1800.

To connect the cables to the RealPresence Collaboration Server (RMX) 1800:

1 Connect the management network cable to LAN 1 port.

When LAN redundancy is enabled, LAN 1 is used for both the management and the media and signaling network connection.

2 Connect the media and signaling cable to LAN 2 port.

By default this port is used for signaling, but when LAN redundancy is enabled, LAN 2 is the backup of LAN 1 port.

3 Connect the PRI cable into any PRI port.

Warning: Use only the Polycom-supplied AC power cable

• Only the AC power cable supplied by Polycom should be used.

• The size of the protective earthing conductor should be a minimum of 10 AWG.

• The outlet intended for connecting the power cord must be protected with an external overcurrent protection device, either in building or in the rack, with the rating not higher than 20 AMP.

• Do not use an extension cord with the cable.

Note: PRI ports on RealPresence Collaboration Server (RMX) 1800 with three DSP cards

Only the RealPresence Collaboration Server (RMX) 1800 with three DSP cards with built-in ISDN module provides PRI ports, as shown next.

Page 22: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Install the RealPresence Collaboration Server (RMX) 1800

Polycom, Inc. 22

RealPresence Collaboration Server (RMX) 1800 with three DSP cards rear panel

Page 23: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 23

Page 24: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 24

First-time Power-up1 For first entry installation, you must insert the USB key containing the modified IP addresses in the

USB slot on the system’s back panel.

For details on how to modify IP addresses, see First Entry Power-up and Configuration in the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide.

2 Turn on the power by pressing on the ON/OFF button located on the front panel of the RealPresence Collaboration Server (RMX) 1800.

The parameters in the lan.cfg file are uploaded from the USB key to the system’s memory and applied during the power-up sequence, which may take up to five minutes.

When the system's configuration is completed (including the Management and IP Network Services), and if there are no system errors, the STATUS LED on the system’s front panel turns green.

3 Remove the USB key.

RealPresence Collaboration Server (RMX) 1800 Front PanelYou can turn the system on or off, and view the system status from its front panel.

Note: Polycom software licenses

You are required to register all Polycom software licenses you have purchased when retrieving the Activation Key. For example, Encryption and Network Separation each have different Polycom software licenses.

No. Name Description

1 LAN 1 LED Off - No network connection

Green - Network connected

Flickering green - In use

Page 25: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 25

RealPresence Collaboration Server (RMX) 1800 Rear PanelThe RealPresence Collaboration Server (RMX) 1800 rear panel contains built-in power and fan units, USB, LAN, serial and PRI ports.

2 LAN 2 LED Off - No network connection

Green - Network connected

Flickering green - In use

3 STATUS LED Red - System alarms

Green - Endpoints are connected to a meeting

Flickering green - No system alarms and no endpoints connected to the meeting

Flickering blue - Diagnostic tests are running

Blue - Diagnostic tests are completed; remove the USB key (if applicable) and restart the system

4 M/S LED Blue - System upgrade completed, waiting for reboot

Flickering blue - System upgrading in progress

Green - The system works normally, either in single mode, or as the master MCU in the hot backup mode

Flickering green - The system works normally, as the slave MCU in the hot backup mode

5 PWR LED Green - Power normal

Red - Power alarms

6 ON/OFF button

Turn the RealPresence Collaboration Server 1800 System on or off

No. Name Description

Page 26: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 26

Power Unit and Status

For version 8.3 and higher, RealPresence Collaboration Server (RMX) 1800 supports a redundant power unit. The two power units back up each other and are hot swappable.

To insert a power unit:

1 Slide the power unit into the chassis until it snaps into place.

The system beeps because it detects a power unit inserted without a power supply connected to it.

2 Connect the unit to a power supply using the supplied power cable.

The system stops beeping.

No. Port Description

1, 2 Power socket and fan

Built-in power socket and fan

3 Serial (RS 232) Diagnostics only

4 USB 1 For USB Key connection; For more information of USB Key connection, see First Entry Power-up and Configuration in the RealPresence Collaboration Server (RMX) 1500/1800/2000/4000 Getting Started Guide

5 USB 2 For USB key connection.

6 LAN 1 For management network connection; when LAN redundancy is enabled, LAN 1 is used for both management, media and signaling network connection

7 LAN 2 For media and signaling network connection; when LAN redundancy is enabled, LAN 2 is the backup of LAN 1 port

8 PRI 3 Note: The ISDN module with PRI ports is only available on RMX 1800 with three DSP cards.

For ISDN network connection, PRI port can work as either an E1 or T1 port, but not simultaneously

Indicator status of the PRI ports are as below:

• Red - ISDN network works abnormally

• Green - ISDN network works normally

• Off - ISDN PRI interface isn’t enabled for any ISDN network service

9 PRI 1

10 PRI 2

11 PRI 4

Note: Get a redundant power unit

Your RealPresence Collaboration Server (RMX) 1800 is shipped with one power unit by default. To get a redundant power unit, contact your channel sales representatives.

Page 27: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 27

3 Switch on the power of the desired power unit.

To remove a power unit:

1 Disconnect the power cable from the power unit.

The system beeps because it detects a power unit inserted without the power supply connected to it.

2 Pull the power unit out using its handle.

The system stops beeping.

To view the power unit status:

» In the RMX Management pane, click Hardware Monitor as shown next.

Page 28: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 28

The following table describes the power unit status.

To troubleshoot the power unit in Abnormal status:

» The power unit status changes to Abnormal in one of the following cases:

One of the power units is not connected to the power supply.

The system beeps because it detects a power unit inserted without a power supply connected to it. You can either connect the power unit to the power supply, or remove it from the system.

One of the power units is removed.

One of the power units fails.

Remove or replace the problem power unit. Power units are hot swappable; you don’t need to restart the system for it to work.

Plug in the power cable again to dismiss the Abnormal status.

Note: DSP and ISDN monitor

The DSP monitor is only available on RMX 1800 with one DSP card and RMX 1800 with three DSP cards, and ISDN monitor is only available on RMX 1800 with three DSP cards.

Status Description

Normal Inserted power units work normally.

Abnormal At least one of the inserted power units work abnormally.

Page 29: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Polycom, Inc. 28

Regulatory Notices

Important SafeguardsRead and understand the following instructions before using the system:

Close supervision is necessary when the system is used by or near children. Do not leave unattended while in use.

Only use electrical extension cords with a current rating at least equal to that of the system.

Always disconnect the system from power before cleaning and servicing and when not in use.

Do not spray liquids directly onto the system when cleaning. Always apply the liquid first to a static free cloth.

Do not immerse the system in any liquid or place any liquids on it.

Do not disassemble this system. To reduce the risk of shock and to maintain the warranty on the system, a qualified technician must perform service or repair work.

Connect this appliance to a mains socket with protected earth connection.

Only connect the system to surge protected power outlets.

Keep ventilation openings free of any obstructions.

If the system or any accessories are installed in an enclosed space such as a cabinet, ensure that the air temperature in the enclosure does not exceed 40°C (104° F). You may need to provide forced cooling to keep the equipment within its operating temperature range.

Do not use this product near water.

Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lighting.

Disconnect BOTH power cords to electrically isolate the system, and before removing any covers.

The appliance inlet can be used as the disconnect device.

No user serviceable parts are contained within the device.

SAVE THESE INSTRUCTIONS.

The device contains a lithium cell. Risk of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type as recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

Page 30: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Regulatory Notices

Polycom, Inc. 29

Remarques importantes concernant la sécuritéLisez les instructions suivantes et assurez-vous de bien les comprendre avant d'utiliser le système :

Supervisez attentivement toute utilisation du système par ou près d'enfants. Ne laissez pas le système fonctionner sans surveillance.

N'utilisez que des rallonges électriques dont le courant nominal est supérieur ou égal à celui du système.

Débranchez toujours le système de la prise secteur avant de le nettoyer, de le dépanner et lorsque vous ne l'utilisez pas.

Ne vaporisez pas de liquides directement sur le système lorsque vous le nettoyez. Appliquez toujours le liquide sur un tissu antistatique.

Ne plongez jamais le système dans un liquide et ne posez jamais de liquide dessus.

Ne démontez pas le système. Pour réduire tout risque d'électrocution et pour maintenir la garantie du système, les travaux de maintenance et de réparation doivent être effectués par un technicien qualifié.

Branchez le système à une prise mise à la terre.

Ne branchez ce système qu'à des prises protégées contre les surtensions.

N'obstruez pas les orifices de ventilation de l'appareil.

Si le système ou des accessoires sont installés dans un espace fermé tel qu'une armoire, veillez à ce que la température de l'air ne dépasse pas 40°C (104° F). Pour maintenir la température dans les limites d'utilisation du système, vous pourrez être amené à prévoir un système de refroidissement forcé.

N'utilisez pas ce produit près de l'eau.

Évitez d'utiliser ce produit pendant un orage. La foudre pourrait causer des électrocutions, même si le risque est faible.

Avant de retirer un capot, débranchez les DEUX câbles d'alimentation pour séparer le système de l'alimentation en électricité.

Remarque : La prise d'entrée de l'appareil peut servir à le débrancher.

Le système ne contient aucune pièce réparable par l'utilisateur.

CONSERVEZ CES INSTRUCTIONS.

L'appareil contient une pile au lithium. Son remplacement par une pile de type incorrect peut entraîner un risque d'explosion. Ne remplacez la pile que par un modèle identique ou équivalent, conformément aux recommandations du fabricant. Mettez les piles usagées au rebut conformément aux instructions du fabricant.

Page 31: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Regulatory Notices

Polycom, Inc. 30

Regulatory Notices

USA and Canadian Regulatory NoticesThis Class [A] digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation.

Russia Regulatory Information

Customs Union (Russia, Belarus, Kazakhstan) Regulatory Information

European Economic Area (EEA)

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense In accordance with part 15 of the FCC rules, the user is cautioned that any changes or modifications not expressly approved by Polycom Inc. could void the user’s authority to operate the equipment.

Система Номер регистрации Дата истечения срока

RMX 1800 Д-СПД-6669 April 03, 2017

Система Номер регистрации Дата истечения срока

RMX 1800 KZ.7500506.23.01.00068 April 21, 2019

European Economic Area (EEA)

Česky [Czech]: Polycom (UK) Ltd tímto prohlašuje, že tento Polycom RMX je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.

Dansk [Danish]: Undertegnede Polycom (UK) Ltd erklærer herved, at følgende udstyr Polycom RMX overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.

Page 32: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Regulatory Notices

Polycom, Inc. 31

Deutsch [German]: Hiermit erklärt Polycom (UK) Ltd, dass sich das Gerät Polycom RMX in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet.

Eesti [Estonian]: Käesolevaga kinnitab Polycom (UK) Ltd seadme Polycom RMX vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.

English: Hereby, Polycom (UK) Ltd. Declares that this Polycom RMX is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

Español [Spanish]: Por medio de la presente Polycom (UK) Ltd declara que el Polycom RMX cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.

Ελληνική [Greek]: ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Polycom (UK) Ltd ∆ΗΛΩΝΕΙ ΟΤΙ Polycom RMX ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ ΤΗΣ Ο∆ΗΓΙΑΣ 1999/5/ΕΚ.

Français [French]: Par la présente Polycom (UK) Ltd déclare que l’appareil Polycom RMX est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.

Italiano [Italian]: Con la presente Polycom (UK) Ltd dichiara che questo Polycom RMX è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.

Íslenska (Icelandic): Hér með lýsir Polycom (UK) Ltd yfir því að Polycom RMX er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC.

Latviski [Latvian]: Ar šo Polycom (UK) Ltd deklarē, ka Polycom RMX atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.

Lietuvių [Lithuanian]: Šiuo Polycom (UK) Ltd deklaruoja, kad šis Polycom RMX atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.

Nederlands [Dutch]: Hierbij verklaart Polycom (UK) Ltd dat het toestel Polycom RMX in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.

Malti [Maltese]: Hawnhekk, Polycom (UK) Ltd, jiddikjara li dan Polycom RMX jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.

Magyar [Hungarian]: Alulírott, Polycom (UK) Ltd nyilatkozom, hogy a Polycom RMX megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.

Norsk [Norwegian]: Polycom (UK) Ltd erklærer herved at utstyret Polycom RMX er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.

Polski [Polish]: Niniejszym Polycom (UK) Ltd oświadcza, że Polycom RMX jest zgodne z zasadniczymi wymaganiami oraz innymi stosownymi postanowieniami Dyrektywy 1999/5/WE.

European Economic Area (EEA)

Page 33: Polycom® RealPresence® Collaboration Server …support.polycom.com/content/dam/polycom-support/products/...Polycom, Inc. 7 Hardware Description This Hardware Guide provides information

Regulatory Notices

Polycom, Inc. 32

Japanこの装置は、情報処理装置等電波障害自主規制協議会(VCCI)の基準

に基づくクラス A 情報技術装置です。 この装置を家庭環境で使用すると電波妨害を引き起こすことがあります。 この場合には使用者が適切な対策を講ずるよう要求されることがあります。

Chinese声明

此为 A 级产品,在生活环境中,该产品可能会造成无线电干扰。在这种情况下,可能需要用户对其干扰采取切实可行的措施。

KoreaA 급 기기 ( 업무용 정보통신기기 )

이 기기는 업무용으로 전자파적합등록을 한 기기이오니

판매자 또는 사용자는 이 점을 주의 하시기 바라며 , 만약

잘못판매 또는 구입하였을 때에는 가정용으로 교환하시기바랍니다 .

Português [Portuguese]: Polycom (UK) Ltd declara que este Polycom RMX está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.

Slovensko [Slovenian]: Polycom (UK) Ltd týmto vyhlasuje, že Polycom RMX spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES.

Slovensky [Slovak]: Polycom (UK) Ltd týmto vyhlasuje, že Polycom RMX spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES.

Suomi [Finnish]: Polycom (UK) Ltd vakuuttaa täten että Polycom RMX tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.

Svenska [Swedish]: Härmed intygar Polycom (UK) Ltd att denna Polycom RMX står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.

A full copy of the Declaration of Conformity can be obtained from Polycom Ltd, 270 Bath Road, Slough, Berkshire, SL1 4DX, UK.

European Economic Area (EEA)