12
ON/OFF MENU SWITCH BATTERY DOOR 1/4 X 20 ACCESSORY IN BASE OF EACH UNIT USE EITHER 3 AA 1.5V ALKALINE OR NICAD BATTERIES OPTIC WINDOW MAGNETIC WALL BRACKET POUCH PLS LD LASER DETECTOR PLS2 and PALM LASER are registered trademarks of PLS PACIFIC LASER SYSTEMS PLS2 utilizes Patented Technology US Patent 6763595 O PERATING M ANUAL FEATURES MENU SWITCH SAFETY LABELING PRESS “ON” TO SCROLL THROUGH THE MENU. THE NUMBERS INDICATE MENU FUNCTIONS: 1. LEVEL/HORIZONTAL BEAM / GREEN LED 2. PLUMB/VERTICAL BEAM / GREEN LED UNLESS THE PLS2 IS ON NUMBER 4 MODE, UNIT WILL NOT OPERATE IF TILT EXCEEDS 6 O OUT OF LEVEL. AMBER LED = LOW BATTERY CAUTION: USE OF CONTROLS, ADJUST- MENTS OR PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE. PLS2 complies with US FDA standards, 21 CFR, 1040.10 and 11. These labels are attached to every PLS laser. These are not to be removed or defaced. PLS • 2550 KERNER BLVD, SAN RAFAEL, CA 94901 WWW.PLSLASER.COM AVOID EXPOSURE LASER RADIATION EMITTED FROM THIS APERTURE PLS2 Palm Laser ON/OFF BUTTON LED 800-601-4500 S/N: PLS2 COMPLIES WITH FDA STDS 21 CFR, 1040.10 AND 11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE 50 DATED 7/26/01 CAUTION LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS MAX OUTPUT POWER <1mW WAVELENGTH 635-670nm CLASS II LASER PRODUCT WARNING LABEL BACK FRONT APERTURE LABEL ID# CERTIFICATION LABEL ® PACIFIC LASER SYSTEMS The Professional Standard 3. BOTH BEAMS - SELF- LEVELING/ GREEN LED 4. BOTH BEAMS - FIXED/ RED LED 5. OFF

PLS2 Palm Laser - EngineerSupply

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PLS2 Palm Laser - EngineerSupply

• ON/OFF MENUSWITCH

•BATTERY DOOR

•1/4 X 20 ACCESSORYIN BASE OF EACH UNIT

•USE EITHER3 AA 1.5VALKALINE ORNICADBATTERIES

•OPTIC WINDOW

•MAGNETICWALL BRACKET

•POUCH

•PLS LD LASERDETECTOR

PLS2 and PALM LASER are registeredtrademarks of PLS • PACIFIC LASER SYSTEMSPLS2 utilizes Patented Technology US Patent 6763595

OPERATINGMANUAL

FEATURES MENU SWITCH SAFETY LABELING

PRESS “ON” TO SCROLL THROUGH THE MENU.THE NUMBERS INDICATE MENU FUNCTIONS:1. LEVEL/HORIZONTAL

BEAM / GREEN LED2. PLUMB/VERTICAL

BEAM / GREEN LED•UNLESS THE PLS2 IS ON NUMBER 4 MODE, UNIT WILLNOT OPERATE IF TILT EXCEEDS 6O OUT OF LEVEL.• AMBER LED = LOW BATTERY

CAUTION: USE OF CONTROLS, ADJUST-MENTS OR PROCEDURES OTHER THANTHOSE SPECIFIED HEREIN MAY RESULTIN HAZARDOUS RADIATION EXPOSURE.

PLS2 complies with US FDAstandards, 21 CFR, 1040.10 and 11.

These labels are attached toevery PLS laser. These arenot to be removed or defaced.

PLS • 2550 KERNER BLVD, SAN RAFAEL, CA 94901WWW.PLSLASER.COM

AVOID EXPOSURELASER RADIATION

EMITTED FROMTHIS APERTURE

PLS2 Palm LaserON/OFF BUTTON LED

800-601-4500

S/N:PLS2 COMPLIES WITH FDA STDS 21CFR, 1040.10 AND 11 EXCEPT FORDEVIATIONS PURSUANT TO LASERNOTICE 50 DATED 7/26/01

C A U T I O NLASER RADIATION

DO NOT STARE INTO BEAM OR VIEWDIRECTLY WITH OPTICAL INSTRUMENTS

MAX OUTPUT POWER <1mWWAVELENGTH 635-670nm

CLASS II LASER PRODUCT

WARNING LABEL

BACK

FRONT

APERTURELABEL

ID# CERTIFICATION LABEL

®

PACIF IC LASERSYSTEMS

The Professional Standard

3. BOTH BEAMS - SELF-LEVELING/ GREEN LED

4. BOTH BEAMS - FIXED/RED LED5. OFF

Page 2: PLS2 Palm Laser - EngineerSupply

CHECK PLUMBCHECK LEVEL WARRANTY SPECIFICATIONS

Light source: Semiconductor laser diode635-670 nm, visible

Working range: +/- 100 feetAccuracy: <1/8” @ 30 Feet

(<3mm @ 10 meters)Leveling: AutomaticLeveling range +/- 6o

Power supply: 3AA batteriesalkaline or rechargeable

Operating time: +25 hours continuous use withsingle beam; 12.5 hours bothbeams

Operating temp: 0o F to 122o F(-18o C to 50o C)

Storage temp: -40 F to 158o F(-40o C to 70o C)

Indicator: Green light: ONRed light: EXCEEDS TILT/TILT OVERRIDE #4Amber light: BATTERY LOW

Environment: Water resistant; not submersibleDimensions: 2” x 2-7/8” x 3-3/8”Weight: 10 oz.(.28kg) (including batteries)

We recommend that you check your PLS2periodically in order to assure its accuracy.

TO CHECK LEVEL:Choose two interior walls approximately 15’-0”apart (see Fig. 1). You can use 2 x 4s for targets.

Turn on the PLS2 to setting #1 (level). With thePLS2 six inches away from and facing target #1,carefully mark the center of the line. Label thismark A1. Swivel the laser 180º and mark the cen-ter of the line on target #2. Label this mark B1.

Move the PLS2 six inches away from and facingtarget #2. Carefully mark the center of the line.Label this mark B2. Swivel the laser 180º andmark the center of the line on target #1. Labelthis mark A2.

You now have two centers of elevation at eachtarget. Carefully measure the distance betweencenters of each set of marks. If there is a differ-ence, subtract one measurement from the other.This calibration method magnifies any error by afactor of two. Therefore divide any difference bytwo to find the true error. Your PLS2 should havean error of no greater than 1/8in. within 30ft.

Choose a door jamb with 8’-0” clear on each sideof the door. Turn on your PLS2 laser to setting #2(plumb). With your laser at point A, make twomarks on the floor: the first at 8’-0” from point Acentered on door header above (mark this pointB), the second 16’-0” from point A (mark this pointC). Without moving the laser, make a third markon the door header (mark this point D).

Move the laser to point C, exactly align the beamwith point B, and notice where the beam falls atpoint D. If it is within a “light” 1/16” of point D, thelaser is in calibration.

This product is warranted by PLS · Pacific LaserSystems to the original purchaser to be free fromdefects in material and workmanship under nor-mal use for a period of one year from the date ofpurchase. During the warranty period, and uponproof of purchase, the product will be repaired orreplaced (with the same or similar model at ouroption), without charge for either parts or labor,through PLS. The purchaser shall bear all ship-ping, packing and insurance costs. Upon comple-tion of the repair or replacement, the unit will bereturned to the customer, freight prepaid. The war-ranty will not apply to this product if it has beenmisused, abused or altered. Without limiting theforegoing, battery leakage, dents or gouges to theplastic housing, broken optic windows, damage tothe switch/LED membrane are presumed to resultfrom misuse or abuse. Tampering with or removalof the caution orcertification labels voids this warranty.

Neither this warranty nor any other warranty,express or implied, including implied warrantiesof merchantability, shall extend beyond thewarranty period. No responsibility is assumed forany incidental or consequential damages. Thiswarranty gives you specific legal rights, and youmay have other rights which varyfrom state to state.

There is nothing an ownercan do in the way of serviceor maintenance on PLStools. Contact PLS or yourlocal service center forrepairs

A

DC

B•

•Target #1Target #2

PALM LASERPLS2

®

PALM LASERPLS2

®

PLS Lab Technicians

A1+

A2

B1+

B2-

15’

If level & plumb are withinspecification, square willbe in specification.

Page 3: PLS2 Palm Laser - EngineerSupply

• INTERRUPTORDE MENÚS ON/OFF

• COMPUERTA DELRECEPTÁCULOPARA LAS BATERÍAS

• ACCESORIO DE 1/4 X 20EN LA BASE DECADA UNIDAD

• UTILICE 3BATERÍAS AADE 1,5V ALCALINAS O NICAD

• OPTIC WINDOW

• SOPORTE DEPARED MAGNÉTICO

• BOLSA DETRANSPORTE

PLS2 y PALM LASER son marcas registradasde PLS o PACIFIC LASER SYSTEMSPLS2 utiliza tecnología patentada: patente US 6763595

MANUAL DE OPERACIÓN

CARACTERÍSTICAS INTERRUPTOR DE MENÚS ETIQUETADO DE SEGURIDAD

PULSE “ON” PARA DESPLAZARSE POR LAS OPCIONES DEL MENÚ.

LOS NÚMEROS INDICAN LAS FUNCIONES DEL MENÚ:

1. NIVEL/HAZ DE LUZ HORIZON

TAL / LED VERDE

2. PLOMADA/HAZ DE

LUZ VERTICAL / LED VERDE

PRECAUCIÓN: EL USO DE CONTROLES,AJUSTES O PROCEDIMIENTOS NO ESPECIFI-CADOS EN ESTA DOCUMENTACIÓN PUEDEPROVOCAR UNA EXPOSICIÓN PELIGROSA ARADIACIÓN.

PLS2 cumple los estándares de laUS FDA, 21 CFR, Subcapítulo J.

Estas etiquetas están adheridas atodos los productos láser de PLS. Nodeben quitarse ni borrarse.

PLS • 2550 KERNER BLVD, SAN RAFAEL, CA 949011WWW.PLSLASER.COM

EVITE LAEXPOSICIÓNRADIACIÓN

LÁSER EMITIDAA TRAVÉS DE

ESTAABERTURA

PLS2 Palm LaserLED DEL BOTÓN ON/OFF LED

PPLS2 CUMPLE LOS ESTÁNDARES DE FUNCIONAMIEN-TO DE LA FDA. 21 CFR, SUBCAPÍTULO J

NÚMERO DE SERIE:MFG'D:

PRECAUCIÓN: RIESGO DE RADIACIÓN LÁSER SI SEABRE EL APARATO. NO MIRE DIRECTAMENTE AL HAZDE LUZ NI CON AYUDA DE INSTRUMENTOS ÓPTICOS.

PATENTE PENDIENTE EN LA OFICINADE PATENTES DE EUA.

PLS 2550 KERNER BLVD, SAN RAFAEL, CA 94901

P R E C A U C I Ó N

RADIACIÓN LÁSERNO MIRE DIRECTAMENTE AL HAZ DE

LUZ NI CON AYUDA DEINSTRUMENTOS ÓPTICOS

POTENCIA MÁX. DE EMISIÓN <1MWLONGITUD DE ONDA 635-670NMPRODUCTO LÁSER DE CLASE II

ETIQUETADO DE ADVERTENCIA

PARTETRASERA

PARTEDELANTERA

ETIQUETADE ABERTURA

ID# ETIQUETA DE CERTIFICACIÓN

®

PACIF IC LASERSYSTEMS

El Estándar Profesional

3. AMBOS HACES - AUTO-

NIVELABLES / LED VERDE

4. AMBOS HACES -

FIJOS / LED ROJO

5. OFF

Page 4: PLS2 Palm Laser - EngineerSupply

COMPROBACIÓN DE PLOMADACOMPROBACIÓN DE NIVEL GARANTÍA ESPECIFICACIONES

Recomendamos que compruebe su PLS2periódicamente para garantizar su precisión.

PARA COMPROBAR EL NIVEL:Elija dos paredes interiores, aproximadamentecon 15' -0” de separación (véase la Fig. 1).Puede utilizar 2 x 4x para los objetivos.

Active el PLS2 en el ajuste #1 (nivel). Con elPLS2 a seis pulgadas del objetivo #1 y mirandohacia el mismo, señale con cuidado el centro dela línea. Etiquete esta marca como A1. Gire elláser 180º y marque el centro de la línea en elobjetivo #2. Etiquete esta marca como B1.

Mueva el PLS2 a seis pulgadas del objetivo #2 ymirando hacia el mismo. Señale con cuidado elcentro de la línea. Etiquete esta marca como B2.Gire el láser 180º y marque el centro de la líneaen el objetivo #1. Etiquete esta marca como A2.

Ahora dispone de dos centros de elevación encada objetivo. Mida con cuidado la distancia entrelos centros de cada conjunto de marcas. Sihubiese alguna diferencia, reste una mediciónde la otra. Este método de calibrado aumentacualquier error por un factor de dos. Por lo tanto,divida cualquier diferencia entre dos para conocerel error real. Su PLS2 debería tener un errorinferior a 1/8 de pulgada a menos de 30 pies.

Elija un montante de puerta con una holgura de 8'-0” respecto a cada lado de la puerta Active elPLS2 en el ajuste #2 (plomada). Con el láser enel punto A, realice dos marcas en el suelo: laprimera a 8' -0” del punto A marcado anterior-mente en la parte superior de la puerta (marqueeste punto como B), el segundo a 16' -0” delpunto A (marque este punto como C). Sin moverel láser, realice una tercera marca en el montantede la puerta (marque este punto como D).

Mueve el láser hasta el punto C, alinee exacta-mente el haz de luz con el punto B y fíjese en ellugar en el que el haz de luz cae sobre el puntoD. Si aparece “luz” a menos de 1/16” del punto D,el láser está calibrado.

Este producto está garantizado por PLS (PacificLaser Systems) al comprador original como librede defectos en materiales y mano de obra, encondiciones normales de trabajo durante un perio-do de un año desde la fecha de adquisición.Durante este periodo de garantía, y tras pre-sentación de prueba de compra, el producto seráreparado o sustituido (por el mismo producto opor un modelo similar, según nuestro criterio), sincargos por piezas o mano de obra, a través dePLS. El comprador asumirá los gastos de envío,empacado y seguros. Tras completar la reparacióno sustitución, la unidad será devuelta al cliente,mediante la modalidad de envío prepagado. Lagarantía no se aplicará a este producto si su usoha sido incorrecto, abusivo o si se ha modificado.Sin perjuicio de lo anterior, las fugas de baterías,abolladuras o cortes en la carcasa de plástico,ventanas ópticas rotas y daños en la membranadel interruptor/LED se entienden como resultadode un uso incorrecto o abusivo. La alteración oeliminación de las etiquetas de precaución o decertificación anulará esta garantía.

Ni ésta ni ninguna otra garantía,expresa o implícita, incluyendolas garantías implícitas de com-erciabilidad, superarán el perio-do de garantía. No se admitiráninguna responsabilidad porcualquier daño inherente o con-siguiente. Esta garantía le otorgaderechos legales específicos,aunque puede que disponga de otros derechosque pueden variar según su ubicación geográfica.A

DC

B•

•Objetivo #1Objetivo #2

PALM LASERPLS2

®

PALM LASERPLS2

®

Técnicos delaboratorio de PLS

A1+

A2

B1+

B2-

15’

Si el nivel y la plomadaestán dentro de lasespecificaciones, laescuadra también lo estará.

Fuente de luz: diodo láser semiconductor635-670 nm, visible

Márgenes de operación: +/- 100 piesPrecisión: <1/8” @ 30 pies

(<3mm @ 10 metros)Nivelación AutomáticaMárgenes de nivelación +/- 6ºAlimentación: 3 baterías AA

alcalinas o recargablesTiempo de operación: +25 horas de uso continuado con un

único haz de luz; 12,5 con los doshaces de luz

Temp. de operación: De 0ºF a 122ºF(De -18ºC a 50ºC)

Temp. de almacenamiento: De -40ºF a 158ºF(De -40ºC a 70ºC)

Indicador: Luz verde: ONLuz roja: INCLINACIÓN EXCESIVA/anulación de inclinación #4Luz ámbar: Nivel de baterías BAJO

Entorno: Resistente al agua, no sumergibleDimensiones: 2” x 2-7/8” x 3-3/8”Peso: 10 oz. (0,28 kg)

(incluyendo las baterías)

Page 5: PLS2 Palm Laser - EngineerSupply

• TASTO ON/OFFE MENU

• COPERCHIO BATTERIA

• ATTACCO FILETTATOPER TREPPIEDE

• UTILIZZA 3 BATTERIEALCALINE AA DA1,5 V O NICAD

• VETRO OTTICA

• STAFFAMAGNETICA A PARETE

• CUSTODIA

PLS2 e PALM LASER sono marchi registrati della PLSPACIFIC LASER SYSTEMS PLS2 utilizza Tecnologia Brevettata,Brevetto US 6763595

MANUALEOPERATIVO

CARATTERISTICHE TASTO ON/OFF E MENU ETICHETTE DI SICUREZZA

PREMERE “ON” PER FAR SCORRERE IL MENU.I NUMERI INDICANO LE FUNZIONI DEL MENU:1. PIANO ORIZZONTALE

RAGGIO/LED VERDE2. PIANO VERTICALE

RAGGIO/LED VERDE

ATTENZIONE: UTILIZZARE I COMANDI, I DISPOSI-TIVI DI REGOLAZIONE O LE PROCEDURE INMODO DIVERSO DA QUANTO SPECIFICATO NELPRESENTE DOCUMENTO, PUO' CAUSARE PERI-COLOSE ESPOSIZIONI A RADIAZIONI.

PLS2 è conforme agli standard USFDA, 21 CFR, Sottocapitolo J.

Queste etichette sono applicate adogni laser PLS. Non rimuoverle nédanneggiarle.

PLS • 2550 KERNER BLVD, SAN RAFAEL, CA 94901WWW.PLSLASER.COM

EVITAREL'ESPOSIZIONEA RADIAZIONI

LASER EMESSEDA QUESTAAPERTURA

PLS2 Palm LaserPULSANTE ON/OFF LED

PLS2 RISPETTA GLI STANDARD DI PRESTAZIONE FDA.CFR 21 SOTTOCAPITOLO J

DATA DI PRODUZIONEMFG'D:

ATTENZIONE: EMISSIONE RADIAZIONI LASER QUANDOAPERTO. NON GUARDARE DIRETTAMENTE IL RAGGIONÉ GUARDARE DIRETTAMENTE CON STRUMENTI OTTI-

CI. BREVETTATO UFFICIO BREVETTI REG. US.PLS 2550 KERNER BLVD, SAN RAFAEL, CA 94901

A T T E N Z I O NRADIAZIONE LASER

NON GUARDARE DIRETTAMENTE IL RAG-GIO NÉ GUARDARE DIRETTAMENTE CON

STRUMENTI OTTICI

POTENZA MAX USCITA <1MWLUNGHEZZA D'ONDA 635-670NM

PRODOTTO LASER CLASSE II

RETRO

FRONTE

ETICHETTAAPERTURA

ETICHETTA DI CERTIFICAZIONE ID#

®

PACIF IC LASERSYSTEMS

Lo Standard Professionale

3. I DUE RAGGI - AUTO-LIVELLANTI / LED VERDE

4. I DUE RAGGI -FISI / LED ROSSO

5. OFF

ETICHETTA DI AVVERTIMENTO

Page 6: PLS2 Palm Laser - EngineerSupply

CONTROLLO DEL PIOMBOCONTROLLO DEL LIVELLO GARANZIA SPECIFICHE

Si consiglia di controllare periodicamente il proprioPLS2 per verificarne la precisione.

PER CONTROLLARE IL LIVELLO:Scegliere due pareti in un interno, a circa 15'-0'' di dis-tanza l'una dall'altra (vedi Fig. 1). E' possibile utilizzaredue pezzi 2x4 come obiettivo. Accendere il PLS2 sul-l'impostazione #1 (livello). Mantenendo il PLS2 a sei pol-lici (1,524 m) dall'obiettivo #1 e rivolto verso di esso,marcare accuratamente il centro della linea.Contrassegnare il segno come A1. Ruotare il laser di180° e marcare il centro della linea sull'obiettivo #2.Contrassegnare questo segno come B1.

Spostare il PLS2 di sei pollici (1,524 m) dall'obiettivo #2mantenendolo rivolto verso di esso. Marcare accurata-mente il centro della linea. Contrassegnare il segnocome B2. Ruotare il laser di 180° e marcare il centrodella linea sull'obiettivo #1. Contrassegnare questosegno come A2.

Ora si hanno due centri di elevazione per ogni obiettivo.Misurare accuratamente la distanza tra i centri di ognigruppo di segni. Se vi è differenza, sottrarre una misuradall'altra. Questo metodo di taratura ingrandisce ognierrore di uno o due fattori. Quindi, dividere eventuali dif-ferenze per due per ottenere l'errore effettivo. L'errorecommesso da PLS2 non dovrebbe superare 1/8 in.(3,175 mm) entro i 30 ft (9,144 m).

Utilizzare il montante di una porta con uno spaziodisponibile di 8'-0'' su entrambi i lati della portastessa. Accendere il PLS2 sull'impostazione #2(piombo). Con il laser sul punto A, fare due segnisul pavimento: il primo a 8'-0'' dal punto A centratosulla testata superiore della porta (marcarequesto punto come punto B), il secondo a 16'-0''dal punto A (marcare questo punto come puntoC). Senza muovere il laser, fare un terzo segnosulla testata della porta (marcarlo come punto D).

Spostare il laser sul punto C, allineare esatta-mente il raggio con il punto B, e controllare se ilraggio cade sul punto D. Se il raggio cade entro1/16'' dal punto D, significa che il laser è calibrato.

Questo prodotto è garantito da PLS o PacificLaser Systems; la garanzia all'acquirente origi-nario copre i difetti di produzione o dei materialiutilizzati per un periodo di un anno dalla data diacquisto a condizione che lo strumento sia utiliz-zato in modo idoneo. Durante il periodo digaranzia, in presenza della prova di acquisto, ilprodotto verrà riparato o sostituito gratuitamente(con un modello identico o simile, a scelta) dallaPLS. Le spese di imballo, spedizione e assicu-razione sono a carico del cliente. Dopo lariparazione o la sostituzione, l'articolo verrà resti-tuito al cliente, in porto franco. La garanzia non havalore se il prodotto è stato utilizzato in modoscorretto, danneggiato o modificato. Fattaeccezione per i casi in cui vi sia stata perdita diliquido dalle batterie, o in cui l'involucro in plasticaoriginale risulti ammaccato o danneggiato, si pre-sume che la rottura delle finestre ottiche, o i dannialla membrana interruttore/LED derivino da uncattivo uso dell'apparecchio. La manomissione ola rimozione delle etichette di sicurezza o di certi-ficazione annullano la presente garanzia.

Nessuna garanzia, espressa o implicita, compresela presente o altre garanzie di commerciabilità,può essere estesa oltre il presente periodo digaranzia. Non si assumono responsabilità perdanni accidentali o consequenziali.La presente garanzia for-nisce specifici diritti legali;altri diritti possono variareda Stato a Stato.

A

D

C

B•

•Obiettivo #1Obiettivo #2

PALM LASERPLS2

®

PALM LASERPLS2

®

Tecnici Lab PLS

A1+

A2

B1+

B2-

15’

Se il livello ed il piombocorrispondono a quantodescritto, la squadra rien-trerà nella descrizione.

Fonte luce: diodo laser semiconduttore635-670 nm, visibile

Raggio di lavoro: +/- 100 piedi (30,48 m)Precisione: <1/8” @ 30 piedi (9,144 m)

(<3mm @ 10 metri)Livellamento: AutomaticoPortata livellamento: +/- 6oAlimentazione: 3 batterie AA alcaline o ricaricabiliAutonomia: +25 ore in uso continuo con un solo

raggio; 12,5 ore con entrambi i raggiCampo di temp. (funzionamento): da 0o F a 122o F

(da -18o C a 50o C)Campo di temp. (stoccaggio): da -40 F a 158o F

(da -40˚ C a 70˚ C)Indicatori: Luce verde: ON

Luce rossa: PENDENZA ECCESSIVAsuperamento della pendenza #4Luce ambra: Batteria scarica

Condizioni ambientali: Resistente all'acqua; non subacqueoDimensioni: 2” x 2-7/8” x 3-3/8”Peso: 10 oz.(.28kg) (batterie incluse)

Page 7: PLS2 Palm Laser - EngineerSupply

• ON/OFF MENÜSCHALTER

• BATTERIETÜR

• 1/4 X 20 ZUBEHÖRUNTEN AN JEDER EINHEIT

• VERWENDEN SIEENTWEDER 3 AA1.5V ALKALI ODERNICAD BATTERIES

• OPTISCHES FENSTER

• MAGNETISCHWANDKLAMMER

• TASCHE

PLS2 und PALM LASER sind registrierteHandelsmarken von PLS o PACIFIC LASER SYSTEMSPLS2 verwendet patentierte Technologie US Patent 6763595

BETRIEBSHANDBUCH

M A D E I N U S A

AUSSTATTUNG MENÜSCHALTER SICHERHEITSETIKETTIERUNG

VORSICHT: DIE VERWENDUNG VON KONTROLLEN,ANPASSUNGEN ODER VERFAHREN AUßER JENEN,DIE IN DIESEM DOKUMENT ANGEGEBEN SIND,KANN DAZU FÜHREN, DASS SIE GEFÄHRLICHER

STRAHLUNG AUSGESETZT WERDEN.

PLS 2 erfüllt die US FDA Normen 21CFR, Unterkapitel J

Diese Etiketten finden sich an jedemPLS Laser. Sie dürfen nicht entferntoder beschädigt werden.

PLS • 2550 KERNER BLVD, SAN RAFAEL, CA 94901WWW.PLSLASER.COM

SETZEN SIE SICHNICHT DER

LASERSTRAHLUNGAUS, DIE VON

DIESER ÖFFNUNGAUSGEHT

PLS2 Palm LaserON/OFF KNOPF LED

PLS2 ERFÜLLT DIE FDA LEISTUNGSNORMEN21 CFR, UNTERKAPITEL J

SERIENNUMMR:FABRIZIERT

VORSICHT: LASERSTRAHLUNG WENN OFFENSTARREN SIE NICHT IN DEN STRAHL ODER SEHEN IHNDIREKT MIT OPTISCHEN INSTRUMENTEN AN. PATENTHÄNGIG

REG. US PATENTAMTPLS 2550 KERNER BLVD, SAN RAFAEL, CA 94901

V O R S I C H TLASERSTRAHLUNG

STARREN SIE NICHT IN DEN STRAHL UNDSEHEN SIE IHN NICHT DIREKT MIT OPTIS-

CHEN INSTRUMENTEN AN

MAXIMALER STROMAUSSTOß <1MWWELLENLÄNGE 635-670NM

LASERPRODUKT DER KLASSE II

WARNETIKETTE

HINTEN

VORNE

ÖFFNUNGSETIKETTE

ID# ZERTIFIZIERUNGSETIKETTE

®

PACIF IC LASERSYSTEMS

The Professional Standard

DURCH WIEDERHOLTES DRÜCKEN WIRD DIE FUNKTIONGEWECHSELT. DIE ZAHLEN ENTSPRECHEN DEN FUNK-TIONEN DES MENÜS.1. NIVELLIERUNG/HORIZONTALER STRAHL/GRÜNES LED2. LOT/VERTIKALER STRAHL/GRÜNES LED3. BEIDE STRAHLE -SELBEST-NIVELLIEREND/GRÜNES LED4. BEIDE STRAHLE-FIXIERT/ROTES LED5. AUSOORANGES LED = SCHWACHE BATTERIEN

Page 8: PLS2 Palm Laser - EngineerSupply

LOTNIVELLIERUNG GARANTIE SPEZIFIKATIONEN

Wir empfehlen, dass Sie Ihr PLS2 periodischüberprüfen, um seine Präzision sicher zustellen.

SO ÜBERPRÜFEN SIE DIE NIVELLIERUNG:Wählen Sie gegenüber-liegende Flächen ImAbstand von ca. 5m (siehe Fig. 1).

Schalten Sie das PLS2 auf Eins (Nivellierung).Stellen Sie das Gerät im Abstand von 15cm vorZiel 1 und markieren Sie sorgfältig die Mitte derLinie, dies ist Punkt A1. Drehen Sie das Gerätum 180° und markieren Sie die Mitte der Linieauf Ziel 2, dies ist Punkt B1.

Stellen Sie das Gerät im Abstand von 15cm vorZiel 2 und markieren Sie sorgfältig die Mitte derLinie, dies ist Punkt B2. Drehen Sie das Gerätum 180° und markieren die Mitte der Linie auf Ziel1, dies ist Punkt A2.

Nun messen Sie jeweils den Abstand zwischenA1 und A2. B1 und B2. Sind die Abständeidentisch. Ist das Gerät kalibriert. Beträgt dieDifferenz mehr als 3mm, so ist der Laser nichtkalibriert.

___ Oberprüfen Sie das Lot:Wählen Sie einen Türrahmen, mit 2.5 m Freiraumauf beiden Seiten (siehe Abbildung 2). SchaltenSie das PLS2 auf Zwei (Lot). Markieren Sie PunktB mitting innerhalb des Türrahmens am Boden.Platzieren Sie das Gerät auf Punkt A undmarkieren Sie folgende Punkte am Boden: PunktB 2.5 m entfernt

von Punkt A mittig unter dem Türrahmen, undPunkt C 5m entfernt von Punkt A. Markieren Sieden Punkt D auf dem Türrahmen, ohne das Gerätzu bewegen.

Nun platzieren Sie das Gerät auf Punkt C undrichten den Strahl genau nach Punkt B aus.Überprüfen Sie, wo der Strahl in Relation zuPunkt D liegt. Wenn die Abweichung weniger als1.6 mm beträgt, ist das Gerät kalibriert.

Sind Nivellierung undLot innerhalb derSpezifikationen ist es dieWinkelfunktion auch.

A

D

C

B•

•Ziel Nummer 1 Ziel Nummer 2

PALM LASERPLS2

®

PALM LASERPLS2

®

PLS Lab Technicians

A1+

A2

B1+

B2-

15’

PLS - Pacific Laser Systems garantiert demersten Käufer, das dieses Produkt frei vonMängeln an Material und Arbeit ist, wenn esinnerhalb von zwei jahren Kaufdatum normalverwendet wird. Während der Garantieperiodeund gegen Vorlage der Kaufquittung wird dasProdukt von PLS repariert oder ersetzt (nachunserer Wahl durch dasselbe oder ein ähnlichesModell), ohne Material- und Arbeitskosten. DerKäufer trägt alle Versand-, Verpackungs- undVersicherungskosten. Nach der Reparatur oderdem Ersatz wird die Einheit an den Kundenzurückgesandt, Fracht vorausbezahlt. DieGarantie ist nicht anwendbar, wenn das Produktfalsch oder missbräuchlich verwendet oderabgeändert wurde. Ohne Beschränkung desvorstehenden gelten Batterielecks, Beulen oderDellen am Plastikgehäuse, gebrochene optischeFenster, Schäden an der Schalter/LED Membranvermutungsweise als Folge einer falschen odermissbräuchlichen Verwendung. Beschädigungoder Entfernung der Sorgfalts- oderBescheinigungsetiketten macht diese Garantieungültig.

Lichtquelle: Halbleiter Laser Diode635-650 nM. sichtbar

Reichweite: ca. 30mAbweichung < 3mm auf 10 MeterNivellierung: AutomatischNivellierungsbereich +/- 6°Stromversorgung: 3 AA Alkali- oder aufladbare BatterienBetriebsdauer: +25 Stunden ununterbrochen mit

einem Strahl 12.5 Stunden mitbeiden Strahlen

Ensatztemperatur -20°C bis 50°CLagertemperatur -20°C bis 70°CLED Anzeigen Grün - einsatzbereit, selbstnivellierend

Grün - blinkend - einsatzbereit, selbst-nivellierend, mit gepulstem StrahlRot - Selbstnivellierung nicht möglich.zu großer NeigungswinkelRot bei Funktion 4 - einsatzbereit.Selbstnivellierung ist abgeschaltetOrange - schwache Batterie

Schutzklasse Spritzwasser - und StaubschutzMaße H.B.L. ca. 83 mm x 52 mm x 70 mmGewicht: ca. 0,3 kg

Page 9: PLS2 Palm Laser - EngineerSupply

• INTERRUPTORDE MENÚS ON/OFF

• COMPUERTADEL RECEPTÁCULOPARA LAS PILAS

• ACCESORIO DE 1/4 X 20EN LA BASE DECADA UNIDAD

• UTILICE 3 PILAS AADE 1,5V ALCALINASO NICAD

• VENTANA ÓPTICA

• SOPORTE DEPARED MAGNÉTICO

• BOLSA DE TRANSPORTE

PLS2 y PALM LASER son marcasregistradas de PLS o PACIFIC LASER SYSTEMSPLS2 utiliza tecnología patentada: patente US 6763595

MANUAL DE FUNCIONAMIENTO

FA B R I C A D O E N E E . U U .

CARACTERÍSTICAS INTERRUPTOR DE MENÚS ETIQUETADO DE SEGURIDAD

PULSE “ON” PARA DESPLAZARSE POR LAS OPCIONES DELMENÚ. LOS NÚMEROS INDICAN LAS FUNCIONES DEL MENÚ:1. NIVEL/HAZ DE LUZ

HORIZONTAL / LED VERDE2. PLOMADA/HAZ DE LUZ

VERTICAL / LED VERDE

PRECAUCIÓN: EL USO DE CONTROLES, AJUSTESO PROCEDIMIENTOS NO ESPECIFICADOS ENESTA DOCUMENTACIÓN PUEDE PROVOCAR UNA

EXPOSICIÓN PELIGROSA A RADIACIÓN.

PLS2 cumple los estándares de la US FDA, 21 CFR,Subcapítulo

Estas etiquetas están adheridas atodos los productos láser de PLS.No deben quitarse ni borrarse.

PLS • 2550 KERNER BLVD, SAN RAFAEL, CA 94901WWW.PLSLASER.COM

EVITE LAEXPOSICIÓNRADIACIÓN

LÁSER EMITIDAA TRAVÉSDE ESTA

ABERTURA

PLS2 Palm Laser DEL BOTÓN ON/OFF LED

PPLS2 CUMPLE LOS ESTÁNDARES DE FUNCIONAMIEN-TO DE LA FDA.

21 CFR, SUBCAPÍTULO J

NÚMERO DE SERIE:MFG'D:

PRECAUCIÓN: RIESGO DE RADIACIÓN LÁSER SI SEABRE EL APARATO. NO MIRE DIRECTAMENTE AL HAZDE LUZ NI CON AYUDA DE INSTRUMENTOS ÓPTICOS.

PATENTE PENDIENTE EN LA OFICINADE PATENTES DE EE.UU.

PLS 2550 KERNER BLVD, SAN RAFAEL, CA 94901

P r e c a u c i ó n

RADIACIÓN LÁSERNO MIRE DIRECTAMENTE AL HAZ DE LUZ NI CON

AYUDA DE INSTRUMENTOS ÓPTICOS

POTENCIA MÁX. DE EMISIÓN <1MWLONGITUD DE ONDA 635-670NMPRODUCTO LÁSER DE CLASE II

ETIQUETADO DE ADVERTENCIA

PARTETRASERA

PARTEDELANTERAT

ETIQUETA DEABERTURA

ID# ETIQUETA DE CERTIFICACIÓN

®

PACIF IC LASERSYSTEMS

El Estándar Profesional

3. AMBOS HACES - AUTO-NIVELABLES / LED VERDE

4. AMBOS HACES -FIJOS / LED ROJO

5. DESACTIVADO

Page 10: PLS2 Palm Laser - EngineerSupply

COMPROBACIÓN DE PLOMADACOMPROBACIÓN DE NIVEL GARANTÍA ESPECIFICACIONES

Recomendamos que compruebe su PLS2periódicamente para garantizar su precisión.

PARA COMPROBAR EL NIVEL:Elija dos paredes interiores, aproximadamentecon 15' -0” de separación (véase la Fig. 1). Puedeutilizar 2 x 4x para los objetivos.

Active el PLS2 en el ajuste #1 (nivel). Con elPLS2 a seis pulgadas del objetivo #1 y mirandohacia el mismo, señale con cuidado el centro dela línea. Etiquete esta marca como A1. Gire elláser 180º y marque el centro de la línea en elobjetivo #2. Etiquete esta marca como B1.

Mueva el PLS2 a seis pulgadas del objetivo #2 ymirando hacia el mismo. Señale con cuidado elcentro de la línea. Etiquete esta marca como B2.Gire el láser 180º y marque el centro de la líneaen el objetivo #1. Etiquete esta marca como A2.

Ahora dispone de dos centros de elevación encada objetivo. Mida con cuidado la distancia entrelos centros de cada conjunto de marcas. Sihubiese alguna diferencia, reste una medición dela otra. Este método de calibración aumentacualquier error por un factor de dos. Por lo tanto,divida cualquier diferencia entre dos para conocerel error real. Su PLS2 debería tener un errorinferior a 1/8 de pulgada a menos de 30 pies.

Elija un montante de puerta con una holgura de 8'-0” respecto a cada lado de la puerta Active elPLS2 en el ajuste #2 (plomada). Con el láser enel punto A, realice dos marcas en el suelo: laprimera a 8' -0” del punto A marcado anterior-mente en la parte superior de la puerta (marqueeste punto como B), el segundo a 16' -0” delpunto A (marque este punto como C). Sin moverel láser, realice una tercera marca en el montantede la puerta (marque este punto como D).

Mueve el láser hasta el punto C, alinee exacta-mente el haz de luz con el punto B y fíjese en ellugar en el que el haz de luz cae sobre el puntoD. Si aparece “luz” a menos de 1/16” del punto D,el láser está calibrado.

Este producto está garantizado por PLS (PacificLaser Systems) al comprador original como librede defectos en materiales y mano de obra, encondiciones normales de trabajo durante un perio-do de un año desde la fecha de adquisición.Durante este periodo de garantía, y tras pre-sentación de prueba de compra, el producto seráreparado o sustituido (por el mismo producto opor un modelo similar, según nuestro criterio), sincargos por piezas o mano de obra, a través dePLS. El comprador correrá con los gastos deenvío, embalaje y seguros. Tras completar lareparación o sustitución, la unidad será devueltaal cliente, mediante la modalidad de envío prepa-gado. La garantía no se aplicará a este productosi su uso ha sido incorrecto, abusivo o si se hamodificado. Sin perjuicio de lo anterior, las fugasde pilas, abolladuras o cortes en la carcasa deplástico, ventanas ópticas rotas y daños en lamembrana del interruptor/LED se entienden comoresultado de un uso incorrecto o abusivo. Laalteración o eliminación de las etiquetas de pre-caución o de certificación anulará esta garantía.

Ni ésta ni ninguna otra garantía,expresa o implícita, incluyendolas garantías implícitas de com-erciabilidad, superarán el perio-do de garantía. No se admitiráninguna responsabilidad porcualquier daño inherente o con-siguiente. Esta garantía le pro-porciona derechos legalesespecíficos, aunque puedeque disponga de otros derechosque pueden variar según suubicación geográfica.

A

C

B•

•Objetivo #1Objetivo #2

PALM LASERPLS2

®

PALM LASERPLS2

®

Técnicos delaboratorio de PLS

A1+

A2

B1+

B2-

15’

Si el nivel y laplomada estándentro de lasespecificaciones,la escuadratambién lo estará.

•D

Fuente de luz: diodo láser semiconductor635-670 nm, visible

Márgenes de funcionamiento: +/- 100 piesPrecisión: <1/8” @ 30 pies (<3mm @ 10 metros)Nivelación AutomáticaMárgenes de nivelación +/- 6ºAlimentación: 3 pilas AA

alcalinas o recargablesTiempo de funcionamiento: +25 horas de uso continuado con un

único haz de luz; 12,5 con losdos haces de luz

Temp. de funcionamiento: De 0ºF a 122ºF(De -18ºC a 50ºC)

Temp. de almacenamiento: De -40ºF a 158ºF(De -40ºC a 70ºC)

Indicador: Luz verde: ONLuz roja: INCLINACIÓN EXCESIVA/anulación de inclinación #4Luz ámbar: Nivel de pilas BAJO

Entorno: Resistente al agua, no sumergibleDimensiones: 2” x 2-7/8” x 3-3/8”Peso: 10 oz. (0,28 kg) (incluyendo las pilas)

Page 11: PLS2 Palm Laser - EngineerSupply

• BOUTON MARCHE/ ARRÊT

• COMPARTIMENT PILES

• ACCESSOIRE 1/4 X 20À LA PARTIE INFÉRIEUREDE CHAQUE UNITÉ

• EMPLOYER 3PILES AA ALCALINESOU AU NICKEL-CADMIUM 1.5V

• FAISCEAUX LASER

• SUPPORT MURALMAGNÉTIQUE

• POCHETTE DE TRANSPORT

• CELLULE DERÉCEPTION POUR PLS2E

PLS2 et LASER CROIX sont les marques déposées dePLS o LE SYSTÈME LASER PACIFIQUE PLS2 emploie laTechnologie Brevetée Brevet US 6763595

MODE D'EMPLOIDES LASER CROIXAUTOMATIQUES

CARACTÉRISTIQUES FONCTIONNEMENT ÉTIQUETAGE DE SÉCURITÉ

QUAND LE PENDULE EST DANS SA PLAGE DE COMPENSATION, PRESSEZ LATOUCHE ON POUR FAIRE DÉFILER LE MENU; LE CHIFFRE INDIQUE LA FONC-TION OBTENUE:1 = FAISCEAU HORIZONTAL, VOYANT VERT2 = FAISCEAU VERTICAL, VOYANT VERT3 = FAISCEAUX HORIZONTAL ET VERTICAL, VOYANT VERT4 = FAISCEAUX HORIZONTAL ET VERTICAL, VOYANT ROUGE (UTILIZATION ENMODE MANUEL)5 = ARRÊT

PRÉCAUTION : L'UTILISATION DE COMMANDES,RÉGLAGES OU PROCÉDURES AUTRES QUE CEUXSTIPULÉS CI-APRÈS POURRAIT ENTRAÎNER UNE

EXPOSITION À DES RADIATIONS DANGEREUSES.

Le PLS2 est conforme aux normesde performances américaines FDAnormes, 21 CFR, sous-chapitre J.

Ces étiquettes sont collées sur tous lesappareils laser PLS.Elles ne doiventpas être enlevées ou abîmées.

PLS • 2550 KERNER BLVD, SAN RAFAEL, CA 94901WWW.PLSLASER.COM

ÉVITER TOUTEEXPOSITIONRADIATION

LASER ÉMISEDEPUIS CETTEOUVERTURE

PLS2 - utilisation intérieureLED

LE PLS2 EST CONFORME AUX NORMES DE PERFORM-ANCES FDA. 21 CFR, SOUS-CHAPITRE J

NUMÉRO DE SÉRIE :MFG'D :

PRÉCAUTION: RADIATION LASER QUAND VOUSOUVREZ L'APPAREIL.

NE PAS FIXER LE FAISCEAU OU LE REGARDERDIRECTEMENT AVEC DES INSTRUMENTS OPTIQUES.BREVET EN COURS AGENCE AMÉRICAINE D'ENREG-

ISTREMENT DE BREVETPLS 2550 KERNER BLVD, SAN RAFAEL, CA 94901

P R É C A U T I O N

RADIATION DU LASERNE PAS FIXER LE FAISCEAU OU LE

REGARDER DIRECTEMENT AVEC DESINSTRUMENTS OPTIQUES

PUISSANCE DE SORTIE MAXIMUM <1MWLONGUEUR D'ONDE 635-670NM

PRODUIT LASER CLASSE II

ÉTIQUETTE D'AVERTISSEMENT

ARRIÈRE

AVANT

ÉTIQUETTED'OUVERTURE

ÉTIQUETTE DE CERTIFICATION ID#

®

SYSTÈME LASERPACIF IQUE

L'Instrument Professionnel Standardisé

BOUTON MARCHE/ARRÊT DEL

Page 12: PLS2 Palm Laser - EngineerSupply

VÉRIFIER LE PLOMBVÉRIFIER LE NIVEAU GARANTIE SPÉCIFICATIONS

Choisir une embrasure avec un espace libre de 8'-0” de chaque côté de la porte. Mettre le PLS2 enposition 2 (plomb). Mettre l' instrument sur le pointA, faire deux marques sur le sol : la première à8'-0” du point A centrée sur la tête de porte setrouvant au-dessus (marquer ce point B), la deux-ième à 16'-0” du point A (marquer ce point C).Sans déplacer le laser, faire une troisième marquesur la tête de porte (marquer ce point D).

Déplacer l'instrument au point C, aligner minu-tieusement le faisceau avec le point B, et faireattention à l'endroit où le faisceau tombe sur lepoint D. S'il tombe à 1/16” seulement du point D,l'instrument est étalonné.

Ce produit est garanti par le Système LaserPacifique PLS sans défaut de matériau et defabrication, dans des conditions normalesd'utilisation et pour une période d'un an à partirde la date d'achat, au profit du premier acheteur.Pendant toute la durée de la garantie, et surprésentation du justificatif d'achat, le produitsera réparé ou remplacé par PLS (par un modèleidentique ou similaire, selon votre choix), sansfrais supplémentaires de main d'œuvre ou depièces. L'acheteur prendra en charge tout fraisde transport, d'emballage et d'assurance. Àl'achèvement de la réparation ou du remplace-ment, l'appareil sera retourné au client, frais detransport payés d'avance. La garantie ne s'appliquera pas si le produit a été incorrectementou abusivement employé, voire détérioré. Ne selimitant aux conditions citées ci-dessus, les fuitesde piles, creux ou gouges sur le boîtier plastique,cassures aux fenêtres optiques, avaries au com-mutateur /à la membrane du DEL sont considéréscomme résultant d'un emploi incorrect ou abusif.Le retrait ou la détérioration des étiquettes de cer-tification ou de précaution annulera cette garantie.

Aucune garantie, explicite orimplicite, y compris garantieimplicite de valeur marchande,ne s'appliquera sur une duréedépassant la période de cettegarantie. Nous n'assumonsaucune responsabilité encas de dommage indirectou important. Cette garantievous accorde des droits légauxspécifiques, qui pourronts'appliquer en plus d'autres droits locaux.A

DC

B•

•Cible 1Cible 2

PALM LASERPLS2

®

PALM LASERPLS2

®

Techniciensde Laboratoire PLS

A1+

A2

B1+

B2-

15’

Si le niveau et le plombsont conformes auxspécifications, l'équerrele sera également

Nous vous recommandons de vérifierpériodiquement votre appareil PLS2 afinde s'assurer de sa précision.

POUR VÉRIFIER LE NIVEAU: Choisir deux paroiintérieures à environ 15'-0” d'intervalle (voir Fig. 1).Vous pouvez employer 2 x 4s comme cibles.

Mettre le PLS2 en position 1 (niveau). Le PLS2 étantà une distance de six pouces et faisant face à la cible1, marquer soigneusement le centre de la ligne.Étiqueter cette marque A1. Faire pivoter le laser de180º et marquer le centre de la ligne sur la cible 2.Étiqueter cette marque B1.

Déplacer le PLS2 pour qu'il soit à une distance desix pouces de la cible 2 et en face de cette dernière.Marquer soigneusement le centre de la ligne. Éti-queter cette marque B2. Faire pivoter le laser de180ºet marquer le centre de la ligne sur la cible 1. Éti-queter cette marque A2.

Vous avez maintenant pour chaque cible deux cen-tres d'élévation. Mesurer soigneusement la distanceentre les centres de chaque série de marques. S'il y aune différence, soustraire une mesure d'une autre.Cette méthode d'étalonnage fait grossir toute erreurpar un facteur de deux. Il faut donc diviser toute dif-férence par deux pour trouver l'erreur précise. Votreappareil PLS2 ne devrait pas comporter d'erreursupérieure à 1/8 pouces dans les limites de 30 pieds. •

Source optique : Diode laser semi-conducteur635-670 nm, visible

Portée de travail : +/- 100 piedsPrécision : <1/8” @ 30 pieds (<3mm @ 10 mètres)Nivellement : AutomatiquePortée de niveau +/- 6oAlimentation : 3 piles alcalines ou rechargeables AAAutonomie : +25 heures d'utilisation continue

avec faisceau simple ;12,5 heures avec deux faisceaux

Température d'utilisation : 0ºF à 122ºF(-18ºC à 50ºC)

Température de stockage :-40ºF à 158ºF(-40ºC à 70ºC)

Indicateur : Voyant vert : MARCHEVoyant rouge :INCLINAISON DÉPASSANT/inclinaison en mode manuel 4Voyant orange : Pile FAIBLE