PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND EQUIPMENT LISTS LMTT does not guarantee that all or any of these facilities or equipment will be available or suitable for the purposes of the visiting company. A visiting company should, in all cases, check with LMTT Technical Management to ensure the information contained herein is up to date and correct. At times some equipment detailed in this document may be temporarily unavailable. Liverpool Playhouse Williamson Square Liverpool L1 1EL Playhouse Stage Door 0151 708 3700 Playhouse Fax 0151 708 3701 Technical Contacts Please email all enquiries to [email protected] Technical Director - Jeff Salmon Senior Production Manager – Sean Pritchard Head of AV – Jennifer Tallon Cahill Head Of Stage – Geoff Dennard Head of Lighting – Kay Haynes Head Of Wardrobe- Jacqui Davies Company Manager- Sarah Lewis Contents Working regulations 2 Auditorium info/Access/Wardrobe/Smoking 3-4 Stage information 5 Stage Equipment 6 Lighting 7-9 Sound/Comms/AV 10-13

PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND EQUIPMENT LISTS

LMTT does not guarantee that all or any of these facilities or equipment will be available or suitable for the purposes of the visiting company. A visiting company should, in all cases, check with LMTT Technical Management to ensure the information contained herein is up to date and correct. At times some equipment detailed in this document may be temporarily unavailable.

Liverpool Playhouse Williamson Square

Liverpool L1 1EL

Playhouse Stage Door 0151 708 3700 Playhouse Fax

0151 708 3701

Technical Contacts

Please email all enquiries to [email protected]

Technical Director - Jeff Salmon

Senior Production Manager – Sean Pritchard

Head of AV – Jennifer Tallon Cahill

Head Of Stage – Geoff Dennard

Head of Lighting – Kay Haynes Head Of Wardrobe- Jacqui Davies

Company Manager- Sarah Lewis

Contents Working regulations 2 Auditorium info/Access/Wardrobe/Smoking 3-4 Stage information 5 Stage Equipment 6 Lighting 7-9 Sound/Comms/AV 10-13

Page 2: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

2

Working regulations It is essential the following regulations and restrictions are noted by all visiting companies. Please ensure that any relevant personnel are made aware of the following. Working time Please note that in accordance with Working Time Regulations 1998 an 11 hour break between working shifts must be scheduled for all members of staff. Furthermore, suitable breaks within shifts must be scheduled to ensure welfare of all staff and all schedules must be agreed in advance. Calls which contravene these rules, and subsequent costs, should be discussed and agreed prior to arrival. Noise at work Please note that in accordance with the Noise at Work Regulations 1989, the Control of Noise at Work Regulations 2005, and for the benefit and care of all staff and members of the public, LMTT reserves the right to monitor and if necessary limit the sound levels for any given performance. Working at Height Please note that in accordance with Working at Height Regulations 2005 and HSE instructions, mobile access equipment such as Tallescopes must be used in accordance with manufacturer’s instructions. Tallescopes are therefore not to be moved with personnel in the basket. A risk assessment for working at height for each production is required which should identify any particular hazard areas such as traps or changes of levels in stage floors and the control measures to safely perform tasks.

We have 36m of Superbeam Catwalk truss and 6 double braked Loadguard 1T chain hoists that can be supplied to provide up to 3 overhead lighting bridges on stage to reduce the requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss the use of catwalk truss. Please bear this in mind when setting schedules and crewing levels for any production. Loading/unloading As per BECTU/TMA Code of Conduct pertaining to get ins/get outs. The visiting company will have ensured the truck is safely packed, with no dangerously balanced items at risk of falling and injuring any member of any crew. A plan of the truck, showing the distribution of items within the truck will be provided in advance. The visiting company will have ensured that boxes, skips and flight cases are safely packed to avoid any unbalanced loads. Weight should be indicated on each item. LMTT will provide lighting should there not be suitable internal lighting on the truck.

Page 3: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

3

Auditorium information Maximum capacity 677 (697 Inc. restricted views) Stalls capacity 256 Circle capacity 196 Gallery capacity 245 There are 5 wheelchair spaces in the stalls and 1 in the Circle Note that sightlines from the Gallery in particular, can be problematic. Please call to discuss if you anticipate issues with this (i.e. there is action DS of iron line) or if you wish to arrange a site visit. Delivery and Access

Access to the Playhouse is through a busy pedestrian shopping area so deliveries must be completed before 10am or after 6pm as there is a rising bollard system over which we have no control. Prior notice must be given to Technical Management should you require access outside of these times. Trailers and diesel vehicles may be left in the delivery bay overnight with prior consent from the Technical Director. Loading and unloading is done at trailer height into the scene dock which has direct access to the stage via the dock iron.

Wardrobe Facilities

The Playhouse has an un-manned wardrobe maintenance department, situated on the third floor. This consists of a washing machine, a spin dryer and a tumble dryer (all professional laundry equipment) along with hand washing facilities. There is also a dedicated wardrobe maintenance room complete with sewing machines.

Dressing Rooms

The Playhouse has 9 dressing rooms situated on the first and second floors. All come complete with cloths rails, chairs, illuminated mirrors, and wash basins. Each floor has toilet facilities and a shared shower block. All dressing rooms have coded door locks which will be issued by stage door to the company/tour manager upon arrival. 1st Floor: 1 four/five person dressing room with washbasin, full length mirror 1st Floor: 1 two person dressing room with en-suite facilities, full length mirror 1st Floor: 3 three person dressing rooms with washbasin, full length mirror 1st Floor: 1 one person dressing room with washbasin, full length mirror 2nd Floor: 3 two person dressing rooms with washbasin, full length mirror

Smoking Policy

Smoking is not allowed in our buildings at any time. Smoking may be allowed by prior arrangement, during a performance where it forms an

essential part of the action, this must be backed up with the relevant H&S documentation.

Page 4: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

4

Stage Information

Rake 1:30 Pros width 9.12m Pros height 5.81m (determined by Iron out position) Stage depth 10.5m Wing to wing 17m Orchestra Pit max width 1.4m Grid height 13.5m (Taken from centre of counterweight 17) Maximum Flying Height 12.7m Dock iron to workshop SR 6.39m (w) x 6.53m (h) Pit lids removable in 1.2m wide sections Please note: Safety curtain must be shown with audience present and must not be obstructed by any permanent scenic elements. Please contact Technical Management to discuss any potential issues. The steps at the side of the orchestra pit are not suitable for public access to the stage. Treads onto stage require the removal of up to18 stalls seats. Trap positions as marked on GP, please contact Technical Management with any queries regarding these. Access routes through the workshop indicated by yellow floor paint must be kept clear at all times during get-ins, rehearsals, performances and get-outs. The route parallel to the dock iron linking the ground floor corridor to FOH is the main access route for Box Office and FOH staff and a secondary fire escape route from the Box Office so if your production intends to use the workshop as a quick change area or has major interval changes could you please inform us so that a suitable management plan can be put into place.

Flying System 32 Counterweight flying sets. All bars are single purchase with the exception of bars 15 and 16 which are double purchase. Single Purchase bar capacity 330kg, double purchase 300kg.

Please note: Counterweight flying operated from stage level SL Loading gallery above @ nominally 8.9m Double purchase bars operated from SL perch @ 2.7m Bars 30 – 32 operated from USL perch @ 2.8m

Standard flying width 10.67m Extended flying width 12.78m (for cloths/soft goods)

Page 5: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

5

Stage Equipment

Motors & hoists

6 1 Ton Loadguards 8m/min (LG10/1/8E/BS) * *Note use of these may be required for suspension of catwalk truss

1 1 Ton Loadstars 8m/min (LG10/1/8E/LV) 2 ¼ Ton Loadguards 8m/min (LG25/1/8E/LV) 2 1 Ton Liftket 5m/min (SB4.1/10J) 2 Distro/control

8 Manual chain hoists

Hoist Power

Upstage left in the loading gallery is located a 63amp three phase CEE-form supply for electric hoists. Up stage right is an additional stage 63amp three phase supply.

Masking/soft goods

Number Item Width (m) Height (m)

1 Full black 12.8 6.1

1 Deep border 12.8 3.5

4 General purpose border 12.8 2.44

1 No.1 Border 10.67 1.83

2 Up and down border 9.14 2.44

4 Legs 1.83 8.44

8 Legs 2.44 8.44

1 White cyclorama 14 8

6 Hard black flat 2 6

There is a tab track mounted on the onstage side of the Loading Gallery to provide US/DS masking in the SL wing. The masking consists of 2m wide black serge legs with a 2m high slit on the centre line of each leg so that access points to stage are available on 1m centres.

Other

1 Harlequin ‘Studio’ Black dance floor to cover whole stage performance area.

Page 6: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

6

Lighting Equipment Profiles 25 Strand SL 15/32 (600w)

25 Strand SL 23/50 (600w) 6 RJ 611SX (Fixed position front of house) Selection of A and B size gobo holders and iris’s available

Advance notice must be given to the Technical Director if you wish to use hired follow- spots, as each position will take out six seats from the upper circle. Fresnel’s 10 Patt. 243 (2kw)

16 Strand Cantata F (1.2kw) 18 CCT Starlette (1kw) All Fresnel’s come complete with barn doors

Floods 10 Strand Iris 1 (1kw)

6 Strand Iris 2 (horizontal) (1kw per unit) 10 Strand Coda 4 (Horizontal) (500w per unit)

Other 30 1kw PAR 64 long nose cans with a selection of lamps (CP60, 61, 62)

12 Source 4 PAR with standard selection of lenses (please ask) and some barn doors (575w)

10 Birdies 240V Automation (Please check for availability)

2 Martin MAC TW1 80V 4 ETC Revolution

(with modules - Iris, shutters, scroller, and gobo rotator) 4 Strand Pirouettes (PC or Fresnel lenses) (2kw tungsten) complete with 8”

Rainbow Pro scrollers 2 Four way Pirouette PSU 20 8” Rainbow Pro scrollers c/w various back plates 2 Maxi PSU 2 Micro PSU

Control 1 ETC GIO

1 ETC Wireless remote DMX distribution to all areas via 4 5-way DMX splitters. Ethernet distribution to all areas via 2 24-way Cat5 TPOE switches. House lights dimmed via ETC Unison Paradigm dimmer system that can either be controlled by the lighting desk or manually via 5 preset and fader outstations at control positions or via touch screen in DSL corner.

Page 7: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

7

Dimming and Power Distribution

ETC Sensor+ dimming system with outlets to all areas (some duplicated sockets).

202 3kW dimmers 10 5kW dimmers 18 3kW Non-dim circuits

24 Ways of 2.5kw portable dimming via 2 x 12 way ETC Smartpack to socapex outputs. (USL Sub stage 200A supply to Power Lock to 2 63a 3 phase CEEform power distro, flight cased) All 5kW outlets are 32A CEEform, non-dim outlets are 16A CEEform. Stage level, pros boom, box boom and loading gallery level 3kW outlets are terminated via 6 way Socapex outlets. Gallery Bar, Gallery front, Circle front and FOH truss 3kW outlets are 15A. All multicore is 6 way Socapex and all IWB’s are 6 way Socapex input with 15A outlets. 63A 3Phase on Loading Gallery for Motors

Effects (Please check availability)

1 Le Maitre Neutron pro Hazer complete with DMX module 1 Le Maitre MVS Hazer 1 Jem AF-1 DMX fan 2 Le Maitre mini mist 1 Le Maitre Microfog 3 Jem ZR-33 DMX Smoke machines 1 Scotty smoke machine (needs hard power) 2 Tiny foggers 1 Martin Magnum 550 smoke machine 1 Le Maitre G-force 1 1 Pulsar MK2 Maxi strobe 1 Skyhigh pyro system 4 pods 3 Dataflash AF1000 2 LED floods 2 LED pixelbars 4 Mirrorball rotator 6 Mirrorball ca. 20 cm diameter 1 Mirrorball ca. 40cm diameter 4 Mirrorball ca. 30 cm diameter 1 Snowboy 1 Soundlab UV cannon

3 Martin Roboscan Pro 918 (575w)

Note: Consumables will be charged at cost.

Page 8: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

8

Colour/Gobo

The Playhouse has a very limited stock of colour and gobo’s please contact the Head of Lighting for further information.

Electrical Equipment

In accordance with the Electricity at Work Regulations, all mains powered equipment brought into the Playhouse must be electrically safe. Evidence may be asked for that relevant safety tests have been carried out. A member of LMTT technical staff may refuse the use of any equipment if they consider it to be unsafe, or in the absence of appropriate certification.

Page 9: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

9

Sound Equipment Please check for availability Mixers 1 Digico SD10 console c/w WAVES expansion card

1 DiGiCo SD11i console c/w WAVES expansion card Stageboxes 1 DiGiCo SD-Rack c/w 4x ADAT cards, 24 analogue XLR inputs, 8 analogue

and 16 aes XLR outputs 1 DiGiCo D-Rack c/w 24 analogue inputs, 8 analogue outputs and 4 digital

stereo outputs. 1 DiGiCo Little Blue Box to connect D-Rack to SD10 1 Soundcraft MH-3 – in storage, check availability

Sound control position is located in the rear stalls and is linked to stage via two 24-way XLR send multicores located DSR and two16-way XLR return multicores to the amp room substage in addition to 4x MADI and multiple Ethernet connections. Outboard Equipment (Please check for availability)

1 WAVES SoundGrid Server and “Essential” plug-ins bundle.

4 Drawmer DL241 compressor 2 Drawmer DS404 quad gate 1 Lexicon MPX550 digital reverb 2 Yamaha SPX2000 Multi FX 2 Yamaha SPX990 FX units

1 XTA G600 graphic equaliser

FOH System

2 d&b C7 serving upper circle rigged on advance truss 4 d&b E9 serving circle and stalls rigged in pros booms 4 d&b C7 Sub’s (two in the orchestra pit, one in each auditorium box)

Other Equipment

11 d&b MAX12 (x6 of which rigged as surrounds in auditorium) 5 d&b MAX 15 (x2 of which rigged as surrounds in auditorium) 4 d&b E3

2 d&b C7 Top 2 d&b C6 2 d&b E18 Sub

4 Galaxy Hotspots (not great) 16 JBL control 1 (including 8 of which rigged as delays and 4 as surrounds) 10 d&b D12 (including 5 in use for FOH system) 14 d&b E-pac (including 6 currently in use for surrounds)

The Playhouse also has the d&b R60 Rope CANBUS interface for remote control of d&b equipment.

Page 10: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

10

Playback (Please check for availability)

1 Qlab v2 system comprising 2x 2.4Ghz Intel Core 2 Duo Mac Mini’s c/w 4gb RAM and 2x Presonus Lightpipe Audio Devices (4x ADAT)

1 Cue One PC with SFX V6 RME Hammerfall DSP, x4 ADAT, Midi 1 DiGiCo UB-MADI 1 RME Fireface 800

2 Intel based Macbook Pro c/w Qlab v2 & Logic 8 2 CueOne CM-8 MIDI trigger “GO” buttons 2 Creamware Sonicore AD16 AD/DA converter 3 Akai S5000 (version 2.14, 256 RAM) 1 Sony MDSE58 mini disk player/recorders 1 Denon 1000F Professional CD player 1 Denon C630 CD player

2 Edirol UA25 1 Edirol UA-101

Mics 1 Crown PZM 30D

1 Crown PZM 6D 3 Crown PCC 160 2 Audio Technica AT835B condenser mics 8 Shure SM 58

4 Shure Beta 58 2 Shure SM57 1 Shure Beta 57

4 Calrec CB20C condenser 1 AKG Drum Package1 x D112, 4 x c418

4 Passive DI boxes EMO 6 Active DI boxes Slazenger

Page 11: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

11

Radio Mics

Ch 21 Equipment Used – Shure G1E 470-530 MHz 470.525 MHz 472.675 MHz 473.550 MHz 474.250 MHz 474.625 MHz 476.950 MHz 477.550 MHz 475.375 MHz

471.350 MHz

Ch 24 Equipment Used – Shure G1E 470-530 MHz 494.300 MHz 499.300 MHz 500.675 MHz 501.200 MHz 496.375 MHz Ch 27 Equipment Used – Shure G1E 470-530 MHz 518.250 MHz 518.825 MHz 519.175 MHz 521.150 MHz 522.475 MHz 523.300 MHz

Page 12: PLAYHOUSE MAINHOUSE TECHNICAL SPECIFICATIONS AND … · requirement for Tallescope use on productions. Please contact the Technical Director or Senior Production Manager to discuss

Liverpool Playhouse Main Auditorium Technical Information June 2015

12

Musical Instruments 1 Takemine electro-acoustic guitar 1 Crafter electro-acoustic guitar 1 Fender Telecaster Deluxe guitar 1 Gibson SG 1 Squire Telecaster guitar 1 Fender Jazz Bass 2 Pod H500 guitar effects pedals 1 Yamaha Alto Sax 1 Roland TD-20 V-Drums package (c/w TD-20D Expansion) 1 Roland Rd-700GX Electric Piano 1 Korg Triton keyboard Sound Power

63A single phase – up stage centre 32A single phase - down stage right (sub stage) 32A single phase – down stage left 16A single phase – control position

Please note: As part of our fire regulations sound /video mains will automatically switch off after three minutes in the event of the fire alarm being activated. AV Equipment

(Shared use with the Everyman & Studio, check for availability) 2 Panasonic PTDZ870EK 8500 lumens WUXGA Projector (standard lens) 3 Panasonic Lens ET-DLE080 1 Panasonic ET-DLE030 Ultra Short Throw lens [0.38:1] 2 Panasonic PT-D6000ES XGA 6500 lumens (Standard Lens, 100mm Zoom

Lens) 2 NEC VT770 XGA (1024 x 768) LCD projectors - 3000 ANSI lumens 4 Sony 40” Plasma 1 Apple Mac Pro 2.8 Quad core, 2xATI Radion HD5770 1GB, 12GB RAM,

4TB storage, Qlab V2 Various sized rear projection screens

Communications The stage management prompt desk can be situated either stage left or stage right and up to a maximum of five meters from the pros wall. It comes complete with colour and infrared monitors of the stage, show relay monitor, front and back stage paging and fourteen cue lights that are patchable to on stage and front of house positions. There is a two channel Metro Audio comms loop that runs throughout the theatre and we also have a Tempest 2.4GHz/900Hz wireless intercom system with 5 belt-packs.