Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
54
60
72
89
Maximum operating pressure = 5000 psi
Maximum valve leakage = 0.07 cc/min.
Port 4 (vent) should never be blocked as seal weepage will eventually cause valve to malfunction.
Will accept pressure at port 4 (vent) but cannot exceed 5000 psi.
40/50
60/70
200/215
465/500
22.2
28.6
31.8
41.3
34.9
34.9
46
63.5
InstallationTorque(Nm)
Cartridge Dimensions
Cavity
TypicalCartridge
Model CodeCapacity
60 L/min.
120 L/min.
240 L/min.
480 L/min.
SPCV2 - 6 - P - D
SPCV2 - 12 - P - D
SPCV2 - 24 - P - D
SPCV2 - 48 - P - D
CV - 278
CV - 277
CV - 276
CV - 275
X Y Z
PILOT OPERATED CHECK VALVE
Vented, 4 Port Cavity
SERIES - SPCV2
SPCV 2
*
*
- - -P
1 2 3 4 5
ORDERING INFORMATION
6 = 60 L/min.
12 = 120 L/min.
24 = 240 L/min.
48 = 480 L/min.
3. Nominal Capacity
2. Model Series - 2
1. Model Code - SPCV
D = 29 psi
5. Cracking Pressure
4. Control - Standard Pilot
Performance Curves Typical Pressure Drop
P=
bar
Q = L/min.6000 150 300 450
30
20
10PD FULL PILOT
SPCV2 - 48
P=
bar
Q = L/min.0 80 160 240 320
30
20
10
PD FULL PILOT
SPCV2 - 24
P=
bar
Q = L/min.1200 30 60 90
30
20
10
PD FULL PILOT
SPCV2 - 12
P=
bar
Q = L/min.
PD FULL PILOT
800 20 40 60
SPCV2 - 630
20
10
54