Add: 5/F, BUILDING 1, 2ND SUB-PARK OF TAOHUAYUAN HIGH-TECH INNOVATION PARK, BAO’AN DISTRICT, SHENZHEN 518000, CHINA Contact: Ms. Sunny Tel: 86-18576652584 Office Line: 86-755-36604974 Email: [email protected] Skype: qlsunny0323 QQ: 2497993595 Professional Manufaturer of Insulin pump NIR therapy device Laser diabetes foot massager ECG machine PC-ECG PHRAY TECHNOLOGY CO.,LTD PHRAY TECHNOLOGY CO.,LTD

Phray English Catalog

Embed Size (px)

Citation preview

Page 1: Phray English Catalog

Add: 5/F, BUILDING 1, 2ND SUB-PARK OF TAOHUAYUAN HIGH-TECH INNOVATION PARK, BAO’AN DISTRICT, SHENZHEN 518000, CHINAContact: Ms. SunnyTel: 86-18576652584Office Line: 86-755-36604974Email: [email protected]: qlsunny0323QQ: 2497993595

Professional Manufaturer of : Insulin pump NIR therapy device Laser diabetes foot massager ECG machine PC-ECG

PHRAY TECHNOLOGY CO.,LTDPHRAY TECHNOLOGY CO.,LTD

Page 2: Phray English Catalog

Company ProfileHigh-tech medical devices manufacturer:Phray is a high-tech enterprise founded in 2000 specializes in manufacturing high-tech medical devices. Main products are insulin pumps, Near-infrared foot therapy device and other medical consumables. Phray insulin pump is one of the world’s a few brands: Phray is one of the world’s leading companies in the Micro-infusion field and is one of the world’s important drafters for insulin pump. There are no more than 10 insulin pump brands in the world and Phray is one of the a few brands.Powerful R&D, QC team:Phray has powerful R&D,QC groups which bring together many world famous doctors/medical experts and engineers. They are at your service all the time with rich experience and professional skills.International cooperation:Phray never stop innovating and making progress. We have been keeping close cooperation relations with many famous medical organizations in the world. With advanced technology, high-tech products and best service, Phray is well known all over the world. As an experienced manufacturer and exporter in medical field, phray is aimed at serving worldwide customers:1.Best OEM/ODM service:OEM/ODM service has been offered for our customers for many years. We can design and manufacture original products for you. If you possess any latest technology achievement or sophisticated technique, or if you are looking for a partner to realize your product or project, welcome to contact Phray, we are very happy to work together with you to reach a new high point.2.Phray is looking for worldwide distributors:Insulin pump is the best way for diabetes treatment but no more than 10 manufacturers in the world. Most of the brands have the problem of high price, complex operation, or poor quality. As an elder in this field, Phray insulin pump is easy to operate, good quality and affordable. And for partners, we have many cooperating policies to help to enlarge business and protect market.We look forward to working together with you to achieve greater success. Welcome to contact!

THANK YOU.

Page 3: Phray English Catalog

CONTENT A. Phray Insulin PumpA. Phray Insulin Pump Terms and ConditionsTerms and Conditions Operating StepsOperating Steps

B. Phray NIR Therapy DeviceB. Phray NIR Therapy Device

C. Phray ECG & PC-ECGC. Phray ECG & PC-ECG

D. Phray Contact InformationD. Phray Contact Information

Page 4: Phray English Catalog

A. Phray Insulin Pump-PH300A. Phray Insulin Pump-PH300

Dear, thank you very much for using Phray Insulin Pump PH300!

4

Phray Technology Co.,Ltd ---Professional Insulin Pump Manufacturer

Page 5: Phray English Catalog

5

Terms and ConditionsTerms and Conditions

• 1. Pls use the device under the guidance of doctors and professionals.

• 2. In order to better set the insulin dosage, pls test your blood sugar at least 3 days before using the device: before and after 3 meals 、 before sleeping 、 3 am and when get up.

• 3. Use rapid acting insulin and short-acting insulin instead of long-acting insulin one day before wearing the insulin pump.

• 4.Check blood glucose frequently during the first week wearing the pump (before and after 3 meals 、 before sleeping 、 3 am and when get up) in order to better setting the pump.

• 5. Avoid using the device while bathing, swimming, strenuous exercise or in high temperature, strong electromagnetic environment.

• 6. Store insulin pens and hypoglycemic drugs to avoid some unexpected emergencies.

• 7. Always pay attention to the alarms, check the pump woking status and check remaining insulin while using the pump to avoid problems.

• 8. Stop using the pump and contact phray representative while any problem.

• 9. Contact your doctor if any unconfortable while using the pump.

Page 6: Phray English Catalog

Operating StepsOperating Steps

11 、、 Preparations Preparations

22 、、 Battery installationBattery installation

33 、、 Time and date settingTime and date setting

44 、、 BasalBasal

55 、、 BolusBolus

66 、、 Rewinding screwRewinding screw

77 、、 Filling the reservoirFilling the reservoir

88 、、 Fixing the reservoirFixing the reservoir

99 、、 ExhaustingExhausting

1010 、、 Wearing pumpWearing pump

1111 、、 Other Common SetupsOther Common Setups

1212 、、 P.S. TroubleshootingP.S. Troubleshooting

PH300 Home ScreenPH300 Home Screen

PH300 ConsumablesPH300 Consumables

6

Page 7: Phray English Catalog

7

1. Preparations1. Preparations

• Get all meterials ready: insulin pump 、 reservoir 、 infusion tube 、 battery 、 battery key 、 regular disinfection appliances 、 rapid acting or short acting insulin ,waterproof tape.

• The insulin should be at room temperature at least 30 minutes before filling the reservoir.

• Pls use rapid acting insulin and short-acting insulin.

Page 8: Phray English Catalog

Overview Of The Pump

Page 9: Phray English Catalog

Menus

Page 10: Phray English Catalog

10

2.Battery Installation2.Battery Installation

• Unscrew the battery compartment cap with the battery key, insert the AAA battery to the battery compartment according to the direction showed on the insulin pump. Then wears the cap again with the key.

Warning: 1.Pay attention to the inserting direction of the battery, otherwise, there may cause damages to the insulin pump.

Page 11: Phray English Catalog

Lock and unlock the screen

• From the home screen, press ▲ firstly and then ▼ to unlock the screen.

• Lock the screen in the same way.

Page 12: Phray English Catalog

12

• From the home screen, press "ACT" to enter the main menu ,use ▲▼ to scroll to "settings” , press ACT to select "Date/Time” , press ▲▼ to set the time and date, press ACT to confirm.

3.Time and Date Setting3.Time and Date Setting

Warning :Adjust Date/Time before doing the next step. The pump can work well and keep right records only when the Date/Time is right.

Page 13: Phray English Catalog

13

• 1.From the home screen, press "ACT" to enter the main menu , scroll to "basal".

• 2.press ACT to select ”basal rate”.

• 3.Set the basal dose by pressing ▲ ▼, press ACT to come to next time segment.

• 4.Check "total" to see if it is right.

• 5.Press ESC to save and exit.

4.1.Basal—Basal Rate4.1.Basal—Basal Rate

Warning: Max basal is 5u/h, Infusion accuracy is 0.1u/h under 24 segments; Infusion accuracy is 0.05u/h under 48 segments.

Page 14: Phray English Catalog

14

• 1. From the home screen, press "ACT" to enter the main menu.

• 2. Select "basal" from the main menu and select "Refer. Basal”.

• 3. Press "▲ ▼" to set the total basal and press ACT to confirm.

• P.S."Time Adjust" is for time zone difference use. If no time zone differences, pls set "0h".

• 4. Press ACT to act.

• 5. Phray insulin pump will set basal rates automatically according to the total basal you set (this basal plan is under 24 segments).

4.2.Basal4.2.Basal -- Refer. BasalRefer. Basal

Warning: This Refer. Basal plan is just for reference , your own final basal plan should be set according to your doctor's advice.

OK

Page 15: Phray English Catalog

5.1.Bolus5.1.Bolus -- Normal BolusNormal Bolus

• NORMAL BOLUS Menu Position : MAIN MENU - BOLUS - NORMAL BOLUS • 1. From the home screen, press "ACT" to enter the main menu.

• 2. Press ACT to select "Bolus" from the main menu and ACT again to select "Normal Bolus”.

• 3. Press "▲ ▼" to set the bolus and press ACT to confirm. The screen shows: "Press ACT to Start or ESC to Return", press ACT to start bolus.

In the process of normal bolus, press ESC can stop infusion.

Page 16: Phray English Catalog

5.2.Bolus5.2.Bolus -- Square Wave BolusSquare Wave Bolus• Square Wave Bolus From the home screen, press ACT to enter main menu, scroll through main menu

and press ACT to select "Bolus"...

1.Start Square Wave Press ACT to select "Square Wave" from Bolus menu. Scroll through Square Wave Menu and press ACT and ▲▼ to set the Units/ Duration. Press ACT to start square wave. The pump home screen shows: SQUARE WAVE

2.Cancel Square Wave Enter "Square Wave" menu according to the above steps. press ACT to select "Cancel SQUARE"...

Warning: The maximum units of Square Wave Bolus is limited by the bolus limits. Min.units for square wave is 2u; Duration can be set 0~240 minutes.

Page 17: Phray English Catalog

17

• 1.From the home screen, press "ACT" to enter the main menu.

• 2.Scroll to "reservoir" by pressing ▲ ▼, press ACT to select "rewind".

• 3.Press ACT to rewind.

• 4.While the pump finishes rewinding, it will shows on the screen: "Rewind Over. Pls Fix Reservoir".

6. Rewinding Screw6. Rewinding Screw

Warning: Don't make any operation until the pump finishes rewinding.

Page 18: Phray English Catalog

18

• Take out the reservoir, push and pull the plunger several times, take off the plunger cap and take out the reservoir protective cap, put it in a clean place.

• Insert the needle of the reservoir into the insulin vial. Pressurise the vial by pushing the plunger down completely. (or invert the reservoir and allow the reservoir to fill. Gently pull the plunger, if necessary.)

• Remove any air bubbles from the reservoir by gently tapping the side and then slowly pushing plunger up a little.

• Remove the reservoir needle and wear the protective cap. Put the reservoir in a clean place.

7. Filling the Reservoir7. Filling the Reservoir

Warning:1.The insulin should be at room temperature at least 30 minutes before filling the reservoir. 2.Wash hands thoroughly before any handling.3.Check if the reservoir package is intact and under guarantee

Page 19: Phray English Catalog

19

• Unscrew the pump compartment cap, insert the reservoir into the compartment, rotate the reservoir gently to fix well. Lock the reservoir with the compartment cap. Remove the reservoir protective cap and connect the reservoir to the infusion tube.

8. Fixing the Reservoir8. Fixing the Reservoir

Page 20: Phray English Catalog

• Press ACT to confirm fixing the reservoir , the pump screen will come to exhausting menu automatically. Press ACT to exhaust, while there are drops at the end of the infusion tube, press ACT to finish exhausting.

20

9.Exhausting9.Exhausting

Warning: pls make sure the needle of the infusion tube is not on human body while exhausting.

Page 21: Phray English Catalog

21

• Wash your hands thoroughly.

• Clean the injection site with alcohol. Remove the needle cap and the cover of the tape. Pinch the injection site gently and insert the infusion needle. Fix the infusion set with the waterproof tape carefully on the body. And the pump home screen shows: BASAL RATE...

IMPORTANT:

Choose a site free of lumps, bumps, bruises, scars and tattoos.

Avoid inserting the infusion set within 5cm of the belly button.

Remember to rotate and cleanse insertion sites. Recommended possible sites:

Abdomen, Outer thigh, Upper buttock, Arm

10.Wearing Insulin Pump10.Wearing Insulin Pump

Page 22: Phray English Catalog

10.10.Wearing Insulin PumpWearing Insulin PumpConfirm that the setups of yourpump are all right and your pumpworks well.Put the pump in the insulinpump case and wear it.

Warning : Severe impact may causedamage to pump, pls make sure wearthe pump properly.

Page 23: Phray English Catalog

23

•Bolus Records Menu Position : MAIN MENU - BOLUS - Bolus Records

Latest 50 records for bolus, check by pressing ▲ ▼. 0313 is the date. 08:00 is the time. 10.0u is the bolus.

11.1.Bolus Review11.1.Bolus Review

Page 24: Phray English Catalog

24

• Basal Records Menu Position : MAIN MENU - Basal - Basal Records

• 1. Under this menu you can check the latest 50 records for basal setup. This data can be used as a reference for your basal plan setup and it's useful for the treat

ment. • 2. “0217” is the date ; “13.8u” means basal total dose. “01” means the last basal setup. “18:00 means the time segment. "0.6u/h” means basal is 0.6u/h during the this time segment.• 3. Press ACT you can check basal records during different date. Press ▲▼ you can check b

asal records during different time segments on the same day.

11.2. Basal Review11.2. Basal Review

Page 25: Phray English Catalog

25

• Daily Records

Menu Position : Main Menu - RESERVOIR - Daily Records

Latest 50 records for daily total dose. Check by pressing▲ ▼. 0313 is the date.

11.3.Daily Review11.3.Daily Review

Page 26: Phray English Catalog

26

• Exhausting Records:

Menu Position : MAIN MUNE - RESERVOIR - Exh. Records

Latest 50 records of exhausting , check by pressing▲ ▼.

0313 is the date.

07:00 is the time.

11.4.Exhausting Review11.4.Exhausting Review

Page 27: Phray English Catalog

27

• Alarm Records Menu Position : MAIN MENU - RESERVOIR - ALARM RECORDS

ALARM RECORDS WILL RECORD THE LATEST 50 RECORDS OF WEAK BATTERY, REWIND, LOW DOSE, BLOCKING...

YOU CAN CHECK THE RECORDS BY PRESSING ▲ ▼.

0313 is the date. 07:00 is the time.

11.5. Alarm Records11.5. Alarm Records

Page 28: Phray English Catalog

28

• Suspend

• Menu Position : Main Menu - Suspend

• From the home screen , press ACT to enter the main menu, scroll through "main menu" and press ACT to select "Suspend". The pump screen shows: "Press ACT to Suspend or ESC to Return".

• When Suspending , any settings and operation can't be performed. Press ACT , do as the pump screen shows to resume.

11.6.Suspending11.6.Suspending

Press ACT to Suspend or ESC to return

Page 29: Phray English Catalog

29

•Basic information checking • From the home screen , press ESC directly to enter the fast ch

ecking screen, you can get date 、 infused dose, and last bolus information.

11.7.Basic Information Checking11.7.Basic Information Checking

2014/08/26Infused:42uLast Bolus:0826 18:00>8.0u

Page 30: Phray English Catalog

30

•Device model checking • From the home screen, press ESC and ▲ ▼ to check the device

model.

11.8. Device model11.8. Device model

MODEL:PH300S/N:3001412**VER:2.08en

Page 31: Phray English Catalog

31

• 1.Blocking Alarm Solution: a.change new battery. b.check if the insulin is run out. c.check or change new reservoir/infusion tube. d.change injection location.• 2.Weak Battery alarm Solution:change new battery• 3.Empty Reservoir Alarm Solution:change new reservoir or suspend• 4.Screen No Display or Automaticly repeat on and off Solution:change new battery• 5.No Delivery Solution:Bolus or Daily total exceeds limit, pls contact your doctor to cha

nge doctor parameter.

12.P.S. Troubleshooting12.P.S. Troubleshooting

Page 32: Phray English Catalog

Phray Insulin Pump PH300•Home Screen:

Page 33: Phray English Catalog

Phray Insulin Pump PH300• PH300 & ACCESSORIES

Page 34: Phray English Catalog

B. Phray NIR Therapy DeviceB. Phray NIR Therapy Device

• PH101 for hospital use & PH102 for family use

Page 35: Phray English Catalog

Treatment Principle

• Nitric Oxide can promote dilation of blood vessels, keep blood vessels clean,prevent from stroke, keep normal Blood Pressure, and also it is an effective weapon for the immune system to cope with pathogens such as bacteria, viruses, tumor cells. This discovery won the Nobel Prize in medicine in 1998.

• Phray NIR device was developed according to this discovery, using particular wavelength near-infrared light source for treatment, these light can reach subcutaneous 5cm, stimulate the tissue to release lots of NO, therefore to dilate blood vessels, improve micro-circulation. Reasonable configuration of special light source ensure the uniformity of illumination, multiple lighting modes ensure good absorption for many different treatment parts.

• Comparing with traditional NIR device, using this device about 30 minutes, local blood circulation increase even several times.

• As a simple, high-effective and easy-to-use physical therapy device, phray NIR diabetes therapy device is safe and has no side effects--it helps to stimulate the rehabilitation of one's immune system by improving one's own local blood circulation. It’s accepted by more and more doctors and patients .

• Same as USA Anodyne Therapy Device

Page 36: Phray English Catalog

Functions• 1.Diabetic peripheral neuropathy treatment

• 2.Neurovascular lesions treatment

• 3.Arthritis treatment

• 4.Neuropathic pain treatment

• 5.Speed up wound healing

• 6.improve secondary sex characteristic development

• 7.improve and restore fertility

• 8.restore sexuality, improve sex quality

• 9.solution to adult lack of growth hormone

• 10. improve bone density, prevent osteoporosis

Page 37: Phray English Catalog

Product Features

• 1. Specific single wave length 890nm.

• 2. Strong penetration, 890nm near-infrared light can reach subcutaneous 5 cm.

• 3. Big energy, one therapy pad energy can reach at a max.800mw

• 4. Light therapy, non-ordinary heat treatment

• 5. A variety of modes, ensure the best therapeutic effect

• 6. Flexible therapy pads, better stick to the affected parts.

• *This device can be used in Physiotherapy, Endocrinology, Neurology, Orthopaedics, surgery, urology departments and for sport teams.

Page 38: Phray English Catalog

Types

• 1.PH100: with 2 therapy pads, can be used by 1-2 patients at the same time, suitable for personal/family use.

• 2.PH101: with 8 therapy pads, can be used by 2--4 patients at the same time, suitable for hospital use.

• 3.PH102: with 4 therapy pads, can be used by 1-2 patients at the same time, suitable for both clinic use, hospital use and family use.

Page 39: Phray English Catalog

C. Phray ECG & PC-ECG (1)C. Phray ECG & PC-ECG (1)

EDS-D

• 1.7 inch 12 leads HD color display (800*600)

• 2.Touch screen + handwriting + keys

• 3.Built-in storage capacity 4G—32G (can store 40,000pcs+ medical records)

• 4.WinCE System, USB/RJ45 Network Interface.

• 5.built-in big capacity lithium battery, continuously work 6+ hours.

• 6.can be connected with external printer

• 7.can be connected to LAN

• 8.weight: 2.0KG

Page 40: Phray English Catalog

C. Phray ECG & PC-ECG (2)C. Phray ECG & PC-ECG (2)

EDS-B

• 1.10.4 inch HD color display (800*600)

• 2.Touch screen + handwriting + keys

• 3.Built-in storage capacity 4G—32G (can store 40,000pcs+ medical records)

• 4.WinCE System, USB/RJ45 Network Interface.

• 5.built-in big capacity lithium battery, continuously work 5+ hours.

• 6.can be connected with external printer

• 7.can be connected to LAN

• 8.weight: 2.3KG

Page 41: Phray English Catalog

C. Phray ECG & PC-ECG (3)C. Phray ECG & PC-ECG (3)

PC-ECG

• Standard 12 leads

• USB port can be connected to computer directly

• Professional ECG software, apply to WINXP/WIN7 System

• Computer medical records management & printing

• Weight: only 200g

Page 42: Phray English Catalog

C. Phray ECG & PC-ECG (4)C. Phray ECG & PC-ECG (4)

Portable EDS-C

• 1.8 inch HD color touch screen display.

• 2.Touch screen + handwriting

• 3.Built-in storage capacity over 32G (can store 320,000pcs medical records)

• 4.built-in big capacity lithium battery, continuously work 6+ hours.

• 5.can be connected with external printer

• 6.can be connected to LAN

• 7.weight: 0.8KG