Page 1: Photo Catalytic Oxidation Passive Oxidative Technology

Photo Catalytic Oxidation

Passive OxidativeTechnology

Page 2: Photo Catalytic Oxidation Passive Oxidative Technology

Acknowledges that HVAC systems play a role in the dissemination of diseases in

buildings

Key points:Infectious diseases can be transmitted

via an airborne path

Designers have a responsibility to minimize that potential

Dilution ventilation Building pressure control

Filtration Oxidative technologies,

UVGI, PCO

ASHRAE Position Paper, June, 2009

2

Page 3: Photo Catalytic Oxidation Passive Oxidative Technology

Passive Oxidation

Page 4: Photo Catalytic Oxidation Passive Oxidative Technology

• What is the Product?• How does the panel work?• Testing• Product Features• Design Considerations• Why they buy• Applications

Page 5: Photo Catalytic Oxidation Passive Oxidative Technology

What is the product?

Photo Catalytic Oxidation Panel (produces oxidizing agent)

First Glance:Filter with a light in it?

Page 6: Photo Catalytic Oxidation Passive Oxidative Technology

Not a Filter / Is a PCO Panel

• Think it is a filter; we have plenty• It is a panel and we have nothing like this• Filter = Commodity• Panel = Technology• Filter = Everyone sells• Panel = Let us consider, More information needed

Page 7: Photo Catalytic Oxidation Passive Oxidative Technology

How does the panel work?Have you ever used hydrogen peroxide on a cut?Did it bubble and boil up?What was it doing? Destroying infection causing virus, bacteria and spores.Our panels create OH. We are trying to replicate the natural process the troposphere uses to clean the air we breathe. “Detergent of the atmosphere”Katja Riedel and Keith Lassey explain how OH, the hydroxyl radical, works to cleansethe atmosphere of harmful trace gases. “Introducing OH, the hydroxyl radicalAlthough it makes up about a fifth of our atmosphere, oxygen (O2) is not the main oxidant. Other molecules that are produced naturally in the atmosphere, including ozone (O3), the nitrate radical (NO3), and the hydroxyl radical (OH), are much more reactive, even if their atmospheric concentrations are low. Radicals are highly reactive because they have unpaired electrons which tend to transfer to other molecules.The OH radical is the most important oxidant in the troposphere, the lowest part of the atmosphere (below about 10 km). Nobel Prize winner Paul Crutzen coined the phrase “detergent of the atmosphere” to describe this important cleansing role of OH. Most of the trace gases found in the troposphere are oxidised by OH into water-soluble products that are washed out by rain and snow. Specifically, OH is responsible for oxidising carbon monoxide (CO) and other carbon-based molecules, such as methane (CH4).”Water & Atmosphere 16(1) 2008http://www.niwa.co.nz/sites/default/files/import/attachments/detergent.pdf

Caution: Two Types – Active (No people) Passive (Safe for Occupied Spaces)

Page 8: Photo Catalytic Oxidation Passive Oxidative Technology

Photocatalysis Process

Redox reaction: A reaction in which electrons are transferred from a donor (the reducing

agent) to an acceptor molecule (the oxidizing agent)

8

Page 9: Photo Catalytic Oxidation Passive Oxidative Technology

Testing / Does it Work?

Extensive 3rd Party and Field Testing

Sample results from 3rd party testing. (With no pre-filter)PCO shows a single pass reduction in microbial contaminants.

Page 10: Photo Catalytic Oxidation Passive Oxidative Technology

Expected Results: Lower levels of VOC’s and Bio-aerosols in the conditioned space

.

10

Page 11: Photo Catalytic Oxidation Passive Oxidative Technology

Residential Unit Single Panel

San Francisco Airport

Scalable / Easy Retrofit

Product Features:

Array of PanelsSide or Front Load

Page 12: Photo Catalytic Oxidation Passive Oxidative Technology

AHU’s:Location – In Air Stream Preferred down stream of coilAdvantages - Low pressure drop (.05@500fpm) Easy to Service (12,000hr lamp) Requires little space (6” panel) Low energy (Cost of ODA) Sustainable (15 year panel) One Device – Three Solutions Cleans Coil Reduces VOCs Destroys Bio aerosols

Page 13: Photo Catalytic Oxidation Passive Oxidative Technology

• Design Goal (Global / At the Source)• Destroys in the airstream with-in the panel (Residence time)• Panels installed across airstream in a rack (Location)• Collection & Type of Contaminates (Source & Concentration)

Design Considerations:

Page 14: Photo Catalytic Oxidation Passive Oxidative Technology

Hospitals:• Odors……. Heliports & Generators• Surface Recharge• Integrity of Design• The O.R. no one will use• State of the Art

Schools:Average Daily AttendanceResistant Strains (T.B.)E.P.A. “Tools for Schools”Lost teaching daysComplaints

Airports:OdorsAirborne pandemic

Casinos:SmokeMoney RoomsEmployee health (Liability Issues)

Animal Care:Kennel CoughOdorsAirborne Viral

Why they buy:

Page 15: Photo Catalytic Oxidation Passive Oxidative Technology

Applications

• Factory Mounted• Retrofit• RTU’s• Induct• Standalone• Portable

Page 16: Photo Catalytic Oxidation Passive Oxidative Technology

Factory mounted AHU (Trane PCC / Custom)

Trane Performance Climate Changer

Page 17: Photo Catalytic Oxidation Passive Oxidative Technology

AHU Retrofit:

Page 18: Photo Catalytic Oxidation Passive Oxidative Technology

Curb Mounted RTU / Thybar

Page 19: Photo Catalytic Oxidation Passive Oxidative Technology

PanelInCurbSupply

Page 20: Photo Catalytic Oxidation Passive Oxidative Technology

Induct:

Page 21: Photo Catalytic Oxidation Passive Oxidative Technology

Standalone:

InletDuctedAttached toFilter grilles

SupplyOut

Page 22: Photo Catalytic Oxidation Passive Oxidative Technology

Portable:

Page 23: Photo Catalytic Oxidation Passive Oxidative Technology

23

Hospital St. Luke’s Vintage Houston TX1. Source Location a. Close proximity to freeway b. Non attainment area c. Automotive and Diesel exhaust migrating into

fresh air vents. d. Ongoing construction

2. Type of Problem a. Ultra fine particles from outdoor pollution ODA - TVOC load. b. Biologic reduction ( Risk reduction HAI )

3. Personnel Location & Challenges a. Limited access behind air handles b. Factory Trane Install for new hospital c. Four story facility 250,000 sq ft.

4. Equipment sizing and location a. 8-Trane Air handlers b. 8-2008 Standard PCP Systems c. 48-PCP Standard Catalyst Panels d. 112 Assorted UVGI lamps e. Spec Merv 13 pre filters in non critical areas and

HEPA Filtration in Critical Areas

Page 24: Photo Catalytic Oxidation Passive Oxidative Technology

24

Hospital John Muir Medical Center Concord CA1. Source Location a. Close proximity to freeway b. Non attainment area c. Close proximity to Helicopter Landing Pad d. Ongoing construction

2. Type of Problem a. Ultra fine particles from outdoor pollution and

high outdoor TVOC load. b. Stage 1 for helicopter odors c. Stage 2 Critical areas bio aerosol reduction

3. Personnel Location & Challenges a. Limited access behind air handles b. Dedicated fresh air unit for c. Five story 168 bed facility d. Field Retro

4. Equipment sizing and location a. One custom dedicated fresh air unit b. Stage 2, three AHUS

Page 25: Photo Catalytic Oxidation Passive Oxidative Technology

25

Hospital Terrebonne General Medical Houma LA1. Source Location a. High environmental fungal levels b. Physical Training Weight Room c. Limited Ventilation d. High people traffic

2. Type of Problem a. Odors from physical training b. Biologic reduction (Risk Reduction HAI )

3. Personnel Location & Challenges a. Rooftop mechanical room isolated b. Field retrofit c. Four story facility 400,000 sq ft.

4. Equipment sizing and location a. 1-Trane Air handlers b. 1-2008 Standard PCP Systems c. 2-PCP Standard Catalyst Panels d. 8 Assorted UVGI lamps e. Spec MERV 13 pre filters in non critical areas

Page 26: Photo Catalytic Oxidation Passive Oxidative Technology

26

Airports San Francisco Airport T 2 Terminal

1. Source Location a. Jet Exhaust and Jet Fuel from runways & gates b. Large volume of people c. High levels of outdoor air required by code

2. Type of Problem a. High levels of outdoor CO & TVOCs

3. Personnel Location & Challenges a. Humid environment / cost of maintenance using capture systems b. Ineffective (off gassing) c. Cost prohibitive 18 month replacement cycle

4. Equipment sizing and location a. 9 Custom AHUs totaling 539,000 cfm b. 474 Catalyst Panels 576 UVGI Lamps c. Equipment installed in the mixing box before the coils because of existing humidity levels and AHU manufacture specs.

Pictures Courtesy of Genesis Air, Inc.

Page 27: Photo Catalytic Oxidation Passive Oxidative Technology

27

Labs Medical Examiners Office & Labs

1. Source Location a. Decomposition bodies in various locations b. The issue - cadavers are moved through out building

2. Type of Problem a. Odors & bio-hazards b. The exhaust system was contaminating an area of several blocks around the facility.

3. Personnel Location & Challenges a. Units had to be near the source b. 12 inch wide returns

4. Equipment sizing and location a. 2 custom 2006 DTs and 4 portable 2006 GS b. The GS units are moved to populates areas. c. The DT units are in the returns near the

source of the contamination.

Pictures Courtesy of Genesis Air, Inc.

Page 28: Photo Catalytic Oxidation Passive Oxidative Technology

28

Casino & Bingo Mohawk Bingo Palace and Casino

1. Source Location a. Environmental Tobacco Smoke

2. Type of Problem a. 30 foot open dome building b. 1600 bingo seats c. HVAC returns are in central location and out of smoke layer. d. Ash tray every 4 feet with 3 to 5 burning

3. Personnel Location & Challenges a. Placement of inlets in smoke layer b. 12 inch wide returns c. Incorporated with EMS system

4. Equipment sizing and location a. 18 2008 GS Units 2 2008 B3s & 6 2008 DTs b. GS units mounted 13 foot level in the smoke layer. c. odor control / AHU return grill mounted

Pictures Courtesy of Genesis Air, Inc.

Page 29: Photo Catalytic Oxidation Passive Oxidative Technology

29

Schools Bellevue Elementary

1. Source Location a. New Construction Late 2009 b. Outdoor Mold and Pollen c. Long Winters

2. Type of Problem a. Under ventilation in winter months b. 80% carpet facility c. Permanent animals in some classrooms

3. Personnel Location & Challenges a. Long Winters less ventilation b. Crowded Classrooms c. Chemicals brought from home by staff to spray or burn in classrooms

4. Equipment sizing and location a. 5 Trane M Series Air Handlers b. Genesis Air units field installed in AHUs during construction c. odor control & biologic control d. Case study available

Pictures Courtesy of Genesis Air, Inc.

Page 30: Photo Catalytic Oxidation Passive Oxidative Technology

Pictures Courtesy of Genesis Air, Inc.

Prisons

Ramsey County Prison St Paul, MN

30

Page 31: Photo Catalytic Oxidation Passive Oxidative Technology

Helping Hands for Humanity Animal Shelter Topeka, KA Pictures Courtesy of Genesis Air, Inc.

31

Page 32: Photo Catalytic Oxidation Passive Oxidative Technology

Pictures Courtesy of Genesis Air, Inc.

Laughlin AFBFuel Maintenance Hanger & PT Building

Fort Sam HoustonCorp of Engineers Regional Offices&Dorm 1001

FLETC PT Building & Command Building

Goodfellow AFBSchool Age Facility& Pipeline Dormitory

Federal

32