PEN EBAR SW-45 rapidRAPI D EXPANSION TA 'ATERSTOP
Penebar Sw-45 rapid" isa concrete joint waterstopdesigned to expand rapidlywhen exposed to water.
50%
40%
30%
1A%
24 48 72 96 120
. after 24 hours :8% expansion w th no sign of deterioration
. after 48 hours :11 % expans ion w i th no s ign o f de te r i o ra t l on
'a f te r 72 hou rs :'15% expansion w th no sign of deterioration
. a f te r 120 hou rs :20% expansion with no sign of deterioratlon
250%
200%
150%
100%
500/"
24 48 72 96 120
. aftea 24 hours :143% expans ion w i th s igns o f c rack ing a tthe edges o f i he samp le
. after 48 hours :170% expansion with spl i ts start ing to showon the s ides o f t he samp le
. afle r 72 hours:195% expans ion
. after 120 hours:215% expans ion and fu r the r expans lonundes i rab e
PENEBAR SW- 45 rapidrM is suitable for use on non-moving co d
construction joints. The nature of i ts expansion characterisi ics makes it
a preferred solution for protection of buiding projects exposed to salt
water or high hydrostatic pressure.
Base slabsFoundalionsRetaining wallsWater relaining structures
Tunnels etc.
K
PENEBAR SW.55CONTROLLED EXPANSION WATERSTOP
Penebar SllU-55" is a concrete joint waterstop that will expandin a controlled fashion when exposed to water. It is a sophisticatedwaieFsealing product that encapsulates hydrophilic materials intoa rubber base to create a built.in delay system.
t{tifil
. It will not expand to a point where the hydralion process
causes it to disintegrate and hence will not be washed away
when subjected to a constant water flow
. lt will not cause excessive intemal pressure in the concrete
Contrclled expansion allows PENEBAR SW-55w to avoid
ofthe problems that have been associated wilh kaditional
waterstops on many building sitesi
. lt does not expand prematurely and does not absorb any
water from fresh concrete poured against it.
70
60
50
40
30
20
1 0
0
. Concrete is allowed to gain full strength before expansion
. Buill-in delay system prevents premature expansion
. Can be bedded into wet concrete
. Does not disintegrate over time
. Not afiected by repeated wet and dry cycles
. Easy to apply to rcugh concrete surfaces
. Can be used in horizontal and verticaljoints
. No problems with compaction or displacement
. Easy to install
. Non-toxic and does not require any special handling
PENEBAR SW-55w can be applied to non-moving, coldjoints on all concrete building projects that need protectionfrom moisture ingress, including;
. Underground structures
. Basements
. Precast panels
. Tunnels
. New concrete onto old concrete
. Manholes
. Lift pits
. Retaining walls
. Storage tanks
. Concrete pipe
. Car parks etc.
PENEBAR SW PRIMERn is
suitable for use with both
PENEBAR SW{s rapidn and
Sw-ssfl a coat ofPENEBAR SW
PRIMER is applied first to the
area where thewaierstop is to
be placed. See back cover for
delalled application instructions. ffiffi
PENEBAR SWSELF HEALING CONCRETE WATERSTOPS
STEP 1 STEP 2 STEP 3 STEP 4 STEP 5
CLEAN SURFACEclean lhe surface suffclenlly
PENEBAR SW PRIlVERfl.
APPLYAOHESIVEApply a coaiofPENEBARSW PRIMERTT to the areawhere lhe PENEBAR SW-
1 sal.(3.78 L) PRIMER- to240 m (787 fl) PENEBAR'
PLACEWATERSTOP
press0re wirh the heelofthe hand, press a oniinuousbead of PENEBAR SW'"nrmy into posil on on thestanding slructure. Makesure ihe pmduct has bonded
BUTT COIL ENDSPeelthe prolect ve backlng
Irom the exposed s de of lhe
nslaIIed PENEBAR SWfi
and I ghlly builthe coilends
Do not ov€r ap coil ends.
POUR CONCRETEPour the mating stftrclura
Follow slandard concreteplac ng p.ocedures lmm
l {o tEs:. A lways use PENEBAR SW PRlt \ ,4ERrM to prevent PENEBAR SWrM from moving dur ng concrete pour ing. Fot ver l ica l
s ! r faces, nai ls may be ' rsed to hoLd the product in p lace. P E N E B A R S W l M s h o u d b e p a c e d a t a m n i m u f i d e p t h o f 5 0 m m ( 2 ) i n s i d e i h e c o n c r e l e. W h e n u s e d o n p i p e s a n d o t h e r s l r u c l u r a l p e n e l r a l i o n s , P E N E B A R S W r M s h o u l d b e c u t l o l h e m e a s u f e d
l e n g t h a n d p l a c e d a r o u n d i h e p e n e t r a t i o n .. On rough atrd i r regular sur faces, a lways ensure thal PENEBAR SWrM rema ns in d rect contact wi th the substrate.
llo_p_qly Tesl Slandard
Co or b ackSpecifc gravi ty ASTM D-71 1.35 05+Hydrocarbon contenl ASTiI D-297 47% ntnvolat ie manef ASTI\ ,1 D 6 l% max.Penelral ian 1509.ncone @ /7'Fs seconds ASTM D'217 40 5'-
PENEBAR SWfi'
IS NOTANEXPANSION JO NTSEALANT AND ONLYSIJ TABLE FORNON.MOVINGCONCRETE JOINTS
. 3om/box = 4/ bs = 21kS
.40 boxes/pa e l = 1200m
. l0 pa e ls /20 conla ider =12000m
. Slze:1gmm x 25mm x5m
Type B :
. 2 4 n l b o t = 2 1 b s = S s k g, 70 bores/palLer = 1680m' 10 pa ets/20 conla ner =16800m' S z e : g m m x 2 5 m m x 4 m
ICS PENETRON INTERNATLONAL LTD. warrants lhat lhe pfoducts manufact ! red by i t shal l be f ree i rom maler ia l defec ls andwi l l conlorrn to iormulat lon standards and conta in a components in thei f proper proport ion. Should any of the prod ' rc ts beproven defect ive, the l lab i l l ly to ICS PENETRON INTERNATIONAL LTD. shal l be l iml led to rep acement o l the rnater a l proven
to be defec l ive and shal l in no case be l iab le o lherwise of for inc identa or consequent ia l damages. ICS PENETRON INTERNA-
T]ONAL LTD. I , IAKES NO WARRANTY AS TO I !4ERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND THIS
WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR I I \ ,4PLIED. UseT sha| I deteTmine the sui labi l i ty o i lheproduct for h is in tended !se and assume al l r isks and l iab ty in conneci ion therew lh.
PENETRONICS/PENETRON INTERNATIONAL LTO.45 Research way Sute 203, East Selauket
te l :631.9419700 la\ :631 941 9777