40
cardiac surgery solutions cardiac surgery solutions Pediatric Cannulae product catalog

Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Embed Size (px)

Citation preview

Page 1: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

cardiac surgery solutionscardiac surgery solutions

Pediatric Cannulaeproduct catalog

Page 2: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit
Page 3: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Table of Contents

Aortic Arch Cannulae 4Curved Tip Aortic Arch Cannulae 4

Straight Tip Aortic Arch Cannulae 7

135° Curved Tip Aortic Arch Cannulae 8

Venous Return Cannulae 12Single Stage 12

Aortic/Venous Polyurethane Cannulae 18

Cardioplegia Cannulae 24Aortic Root Cannulae 24

Retrograde Cardioplegia Cannulae 25

Suction Products 28

Vent Catheters 32

Code index 34

Page 4: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit
Page 5: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Aortic Arch Cannulae

Page 6: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

4

Curved Tip Aortic Arch CannulaeSorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit in the cardiopulmonary bypass procedures in order to return the aortic blood from the circuit into the patient blood flow path.Sorin Group’s Pediatric Aortic Cannulae are available with bent and straight tip, with wire and without wire reinforcement, with or without connector and optional luer lock for venting.Our Aortic Cannulae are designed to optimize flow characteristics, reduce turbulence and minimize pressure loss. The tubing in clear and transparent, no DOP, medical grade PVC, lower elasticity loss during hypothermia.

An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: A211-38 C Not coated

BA211-38 C Coated

Aortic Arch Cannulae

A version B version C version N version

Page 7: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Aortic Arch Cannulae

5

Cannula Tip Size

Connector without

vent

Connector with luer

vent No

ConnectorConnector

SizeEffective

Length (cm)Qty per

boxAvailable Coated

9 Fr/3.0 mm A211-30C A211-30B A211-30N 1/4" 22 10 yes

12 Fr/3.8 mm A211-38C A211-38B A211-38N 1/4" 23 10 yes

14 Fr/4.5 mm A211-45C A211-45B A211-45N 1/4" 23 10 yes

Aortic Arch Curved Tip with Suture Flange, Wire-reinforced Tubing

Cannula Tip Size

Connector without

ventConnector with

luer vent Connector

SizeEffective

Length (cm) Qty per box Available Coated

9 Fr/3.0 mm A212-30C A212-30B 1/4" 22 10 yes

12 Fr/3.8 mm A212-38C A212-38B 1/4" 23 10 yes

14 Fr/4.5 mm A212-45C A212-45B 1/4" 23 10 yes

*Connectors reference pag. 4

*Connectors reference pag. 4

Aortic Arch Curved Tip with Suture Flange, non reinforced Tubing

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

F9 F12 F14

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

F9 F12 F14

Page 8: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

6

Aortic Arch Curved Tip with Collar, Wire-reinforced Tubing

Cannula Tip Size

Connector without

ventConnector with

luer vent Connector

SizeEffective

Length (cm) Qty per box Available Coated

9 Fr/3.0 mm A222-30C A222-30B 1/4" 22 10 yes

12 Fr/3.8 mm A222-38C A222-38B 1/4" 22 10 yes

14 Fr/4.5 mm A222-45C A222-45B 1/4" 23 10 yes

Cannula Tip Size

Connector without

vent

Connector with luer vent down

Connector with luer vent up

Connector Size

Effective Length (cm)

Qty per box

Available Coated

9 Fr/3.0 mm A221-30C A221-30B - 1/4" 22 10 yes

12 Fr/3.8 mm A221-38C A221-38B A221-38A 1/4" 22 10 yes

14 Fr/4.5 mm A221-45C A221-45B - 1/4" 23 10 yes

Aortic Arch Curved Tip with Collar, Non-reinforced Tubing

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

F9 F12 F14

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

F9 F12 F14

*Connectors reference pag. 4

*Connectors reference pag. 4

Page 9: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

7

Aortic Arch Cannulae Straight Tip with Suture Collar, Wire-reinforced Tubing

Cannula Tip Size

Connector without

ventConnector with

luer vent Connector

SizeEffective

Length (cm) Qty per box Available coated

9 Fr/3.0 mm A232-30C A232-30B 1/4" 22 10 yes

12 Fr/3.8 mm A232-38C A232-38B 1/4" 23 10 yes

14 Fr/4.5 mm A232-45C A232-45B 1/4" 23 10 yes

Straight Tip Aortic Arch Cannulae

Aortic Arch Cannulae

Flow (lpm)P

ress

ure

dro

p (m

mH

g)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F9 F12 F14

*Connectors reference pag. 4

Page 10: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

8

Cannula Tip Size No Connector Connection

SizeEffective

Length (cm) Qty per box Available coated

5 Fr/1.5 mm A272-15N 3/16"-1/4" 22 10 yes

6 Fr/2.0 mm A272-20N 3/16"-1/4" 22 10 yes

8 Fr/ 2.6 mm A272-26N 3/16"-1/4" 22 10 yes

9 Fr/3.0 mm A272-30N 3/16"-1/4" 22 10 yes

11 Fr/3.5 mm A272-35N 3/16"-1/4" 22 10 yes

12 Fr/3.8 mm A272-40N 3/16"-1/4" 22 10 yes

14 Fr/4.5 mm A272-45N 3/16"-1/4" 22 10 yes

135° Curved Tip with Collar, Wire-reinforced Tubing

135° Curved Tip Aortic Arch Cannulae

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F5 F6F8 F9 F11 F12 F14

*Connectors reference pag. 4

Page 11: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

9

Aortic Arch Cannulae

135° Curved Tip with Collar and Suture Ring, Wire-reinforced Tubing

Cannula TipSize No Connector Connection

SizeEffective

Length (cm) Qty per box Available coated

8 Fr/ 2.6 mm A900-98 3/16"-1/4" 22 10 yes

9 Fr/3.0 mm A900-153 3/16"-1/4" 22 10 yes

11 Fr/3.5 mm A900-154 3/16"-1/4" 22 10 yes

12 Fr/3.8 mm A900-155 3/16"-1/4" 22 10 yes

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 4.03.5

F8 F9 F10 F12

*Connectors reference pag. 4

Page 12: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit
Page 13: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Venous Return Cannulae

Page 14: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

12

Single Stage Venous Return CannulaSorin Venous Cannulae are intended to be used as connections to the extracorporeal circuit in cardiopulmonary bypass procedures to drain venous blood from the patient.Sorin Group pediatric single stage cannulae are available with optimized 90° angle tip to grant optimum venous return.The tubing is clear and transparent, medical grade, atossic PVC and is designed to lower elasticity loss during hypothermia.

An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: V122-18 Not coated BV122-18 Coated

Venous Return Cannulae

Page 15: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

13

Venous Return Cannulae

Single Stage, Straight Lighthouse Tip Venous Return Cannulae Wire-reinforced Tubing

Cannula Size Catalog N° Connector Acceptance

Effective Length (cm) Qty per box Available

Coated

12 Fr RV-40012 1/4" 30.5 10 no

14 Fr RV-40014 1/4" 30.5 10 no

16 Fr RV-40016 1/4" 30.5 10 no

18 Fr RV-40018 1/4"-3/8" 35.5 10 no

20 Fr RV-40020 1/4"-3/8" 35.5 10 no

22 Fr RV-40022 1/4"-3/8" 35.5 10 no

24 Fr RV-40024 1/4"-3/8" 35.5 10 no

Single Stage, Bullet Tip Venous Return Cannulae Wire-reinforced Tubing

Cannula Size Catalog N°Connector Acceptance

Effective Length (cm) Qty per box

Available Cotaed

14 Fr V122-14 1/4" 30 10 yes

16 Fr V122-16 1/4" 30 10 yes

18 Fr V122-18 1/4" 30 10 yes

20 Fr V122-20 1/4" 30 10 yes

22 Fr V122-22 1/4" 30 10 yes

Flow (Ipm)

Pre

ssur

e d

rop

(mm

Hg)

10

10

20

30

40

50

60

70

80

90

100

02 3 4 5 6

F24

F12 F22F20F18F16F14

0 1 2 3 4 5 6 7 8Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

Page 16: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

14

Single Stage, Right Angle Lighthouse Tip Venous Return Cannulae Wire-reinforced Tubing

Cannula Size Catalog N° Connector

Acceptance Tip Length (cm) Qty per box Available Coated

12 Fr RV-41012 1/4" 2.5 10 no

14 Fr RV-41014 1/4" 2.5 10 no

16 Fr RV-41016 1/4" 2.5 10 no

18 Fr RV-41018 1/4"-3/8" 3 10 no

20 Fr RV-41020 1/4"-3/8" 3.5 10 no

22 Fr RV-41022 1/4"-3/8" 3.5 10 no

24 Fr RV-41024 1/4"-3/8" 4 10 no

Flow (Ipm)

Pre

ssur

e d

rop

(mm

Hg)

10

10

20

30

40

50

60

70

80

90

100

02 3 4 5 6

F24

F12 F22F20F18F16F14

Page 17: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

15

Venous Return Cannulae

Single Stage, 90° Tip Venous Return Cannulae without Collar, Wire-reinforced Tubing

Cannula Tip Size

Connector without vent

Connector with luer vent

Connector Size

Effective Length (cm) Qty per box

12 Fr V900-142 3/16"-1/4" 26 10 yes

14 Fr V900-143 3/16"-1/4" 26 10 yes

16 Fr V900-144 1/4" 26 10 yes

18 Fr V900-145 1/4" 26 10 yes

Cannula Size Catalog N° Connector

AcceptanceEffective

Length (cm) Qty per box Available Coated

10 Fr V132-10 3/16"-1/4" 25 10 yes

12 Fr V132-12 3/16"-1/4" 26 10 yes

14 Fr V132-14 1/4" 26 10 yes

16 Fr V132-16 1/4" 26 10 yes

18 Fr V132-18 1/4" 27 10 yes

20 Fr V132-20 1/4" 27 10 yes

Single Stage, 90° Tip Venous Return Cannulae with Collar, Wire-reinforced Tubing

0 1 2 3 4 5 6 7 8Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

Flow (lpm)

Pres

sure

dro

p (m

mH

g)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F10 F12 F14 F16

F18

F20

Page 18: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit
Page 19: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Aortic/Venous Polyurethane Cannulae

Page 20: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

18

Sorin Group offers a complete range of pediatric cannulae validated for aortic and venous cannulation produced with polyurethane tubing characterized by a very thin wall thickness and design to optimize flow and improve biocompatibility. These cannulae are available in different sizes for pediatric and small adults with side holes to optimize flow dynamics. The introducer, with its tapered or rounded tip, facilitates cannula insertion.

An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: PUN0131 Not coated BPUN0131 Coated

Aortic/Venous Polyurethane Cannulae

Page 21: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

19

Aortic/Venous Polyurethane Cannulae

Cannula Size

Rounded Introducer Side Holes Connector

AcceptanceEffective

Length (cm)Qty

per boxAvailable Coated

12 Fr PUN0131 yes 1/4"-3/16" 10 10 yes

Polyurethane Cannulae, Straight Tip with Suture Ring, Wire-reinforced Tubing and Introducer, 10 cm Length

Cannula Size

Tapered Introducer

Rounded Introducer Side Holes Connector

AcceptanceEffective Length

(cm)Qty

per boxAvailable Coated

8 Fr PUN0032 PUN0127 no 1/4"-3/16" 10 10 yes

10 Fr PUN0033 - yes 1/4"-3/16" 10 10 yes

12 Fr PUN0034 - yes 1/4"-3/16" 10 10 yes

14 Fr PUN0035 - yes 1/4"-3/16" 10 10 yes

Polyurethane Cannulae, Straight Beveled Tip with Suture Ring, Wire-reinforced Tubing and Introducer, 12 cm Length

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F8 F10 F12 F14

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.5 3 3.3

F12

Page 22: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

20

Cannula Size Suture Ring No Suture

RingSide

HolesConnector Acceptance

Effective Length (cm) Qty per box Available

Coated

8 Fr - PUN0048 no 1/4"-3/16" 20 10 yes

10 Fr - PUN0049 yes 1/4"-3/16" 20 10 yes

12 Fr PUN0038 PUN0050 yes 1/4"-3/16" 20 10 yes

14 Fr - PUN0046 yes 1/4"-3/16" 20 10 yes

16 Fr - PUN0051 yes 1/4" 20 10 yes

Polyurethane Cannulae, Straight Tip with Suture Ring, Wire-reinforced Tubing and Introducer, 15 cm Length

Cannula Size

Rounded Introducer Side Holes Connector

AcceptanceEffective

Length (cm)Qty

per boxAvailable Coated

8 Fr PUN0128 yes 1/4"-3/16" 15 10 yes

10 Fr PUN0130 yes 1/4"-3/16" 15 10 yes

12 Fr PUN0132 yes 1/4"-3/16" 15 10 yes

14 Fr PUN0133 yes 1/4"-3/16" 15 10 yes

16 Fr PUN0134 yes 1/4" 15 10 yes

Polyurethane Cannulae, Straight Tip, Wire-reinforced Tubing and Rounded Introducer, 20 cm Length

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F8 F10 F12 F14F16

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F8 F10 F12 F14 F16

Page 23: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

21

Cannula Size

Rounded Introducer

Tapered Introducer Side Holes Connector

AcceptanceEffective

Length (cm)Qty

per boxAvailable Coated

12 Fr PUN0013 PUN0140 yes 1/4"-3/16" 25 10 yes

14 Fr - PUN0139 yes 1/4"-3/16" 25 10 yes

14 Fr - PUN0027 yes 1/4"-3/16" 25 10 yes

16 Fr - PUN0141 yes 1/4" 25 10 yes

16 Fr - PUN0031 yes 1/4" 25 10 yes

Polyurethane Cannulae, Straight Beveled Tip with Suture Ring, Wire-reinforced Tubing Tapered Introducer, 20 cm Length

Cannula Size Catlog N° Side Holes Connector

AcceptanceEffective

Length (cm) Qty per box Available Coated

19 Fr PUN0153 yes 3/8" 20 10 yes

19 Fr PUN0164 yes1/4" with barbed

connector20 10 yes

21 Fr PUN0161 yes 3/8" 20 10 yes

23 Fr PUN0163 yes 1/2" 20 10 yes

Polyurethane Cannulae, Straight Beveled Tip with Suture Ring, Wire-reinforced Tubing Introducer, 25 cm Length

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F12 F14 F16

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

F19 F21 F23

Aortic/Venous Polyurethane Cannulae

Page 24: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Cannula Size

Rounded Introducer Side Holes Connector

AcceptanceEffective

Length (cm) Qty per box Available Coated

10 Fr PUN0028 yes 1/4"-3/16" 32 10 yes

12 Fr PUN0029 yes 1/4"-3/16" 32 10 yes

Polyurethane Cannulae, Straight Tip without Suture Ring, Wire-reinforced Tubing Introducer

Cannula Size

Rounded Introducer Side Holes Connector

AcceptanceEffective

Length (cm) Qty per box Available Coated

12 Fr PUN0150 no 1/4"-3/16" 15 10 yes

14 Fr PUN0151 no 1/4"-3/16" 20 10 yes

16 Fr PUN0152 no 1/4" 20 10 yes

Polyurethane Cannulae, Straight Tip without Suture Ring, Wire-reinforced Tubing, Introducer, 32 cm Length

22

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

F12 F14 F16

Flow (lpm)

Pre

ssur

e d

rop

(mm

Hg)

0.0 0.5 1.0 1.5 2.0 2.5

F10 F12

Page 25: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Cardioplegia Cannulae

Page 26: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

24

Cardioplegia Cannulae

Aortic Root CannulaeSorin Group Aortic Root Cannulae are available with or without a vent line. The long version is designed for minimally invasive procedures. All the Aortic Root Cannulae may be used with several unique adapters developed to deliver cardioplegia solution, and to vent the left heart, during cardiopulmonary bypass surgery. CalMed Laboratories' Aortic Root Cannulae are available in several different configurations to meet user's specific requirements.

Cannula Tip Size

Insertion needle

without vent line

Effective Length (cm) Qty per box Available

Coated

18 Ga (4 Fr) 20 Ga - Gold AR-11018 12.5 10 no

Aortic Root Cannulae with & without Vent Line

Page 27: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Cardioplegia Cannulae

25

Cannula Tip Size

Without Stylet

Guidewire Stylet w/o

HandleEffective

Length (cm) Qty per box Available Coated

10 Fr RCM-14510 RCM-14110 24 10 no

CIRCINUSTM Retrograde Cardioplegia Cannulae with Manually-Inflating Silicone balloon

Retrograde Cardioplegia Cannulae

0 0.05 0.1 0.15 0.2 0.25 0.3 0.4 0.5 0.6

180

160

140

120

100

80

60

40

20

0

Flow (Ipm)P

ress

ure

dro

p (m

mH

g)

F10

Page 28: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit
Page 29: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Suction Products

Page 30: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

28

Sorin Group offers intracardiac suction devices to remove excess fluid from the surgical field. These are specifically designed for pediatric patients, and are available with ergonomic plastic grip or rigid tubing.

An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: S353-50 Not coated BS353-50 Coated

Suction Products

Page 31: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Suction Products

29

Sucker with fluted tip and plastic handle

Sucker with fluted tip and metal handle

Cannula Tip Size Catalog N° Slip Connector Qty per box Available Coated

15 Fr S353-50 1/4" 10 yes

8 Fr S354-25 1/4" 10 yes

Cannula Tip Size Catalog N° Slip Connector Qty per box Available Coated

15 Fr S361-50 1/4" 10 yes

Page 32: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

30

Page 33: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Vent Catheters

Page 34: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

32

Sorin Group offers vent catheters with side holes to improve the venting of the heart.

Vents Catheters

Page 35: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Vents Catheters

33

Vent Catheters, PVC soft tubing, Straight Bullet Tip, without Guidewire Stylet

Vent Catheters, PVC tubing, Straight Bullet Tip, with Guidewire Stylet or Right Angle, Bullet tip, without Stylet

Cannula Size

Straight tip with

Guidewire Stylet

Right Angle

without Stylet

Right Angle length

(cm)

Tip Perforation

(cm)

Effective Length

(cm)Connection

sizeQty per

boxAvailable Coated

10 Fr VT-84410 VT-84510 3.8 2 32 1/4" 10 no

13 Fr VT-84413 VT-84513 5.1 3.8 32 1/4" 10 no

Cannula Size Catalog N° Tip Perforation

(cm)Effective

Length (cm)Connection

size Qty per box Available Coated

12 Fr W900-108 - 41 1/4" 10 yes

Page 36: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

34

Code index

A211-30C........A211-38C........A211-45C........A211-30B........A211-38B........A211-45B........A211-30N........A211-38N........ A211-45N........A212-30C.......A212-38C........A212-45C........A212-30B........A212-38B........ A212-45B........ A221-38A.......A221-30C........A221-38C........A221-45C........A221-30B........A221-38B........ A221-45B........ A222-30C........A222-38C........ A222-45C........ A222-30B........ A222-38B........ A222-45B........ A232-30C........ A232-38C........ A232-45C........ A232-30B........ A232-38B........ A232-45B........ A272-15N........ A272-20N........ A272-26N........ A272-30N........ A272-35N........ A272-40N........ A272-45N........ A900-98.......... A900-153......... A900-154......... A900-155......... AR-11018.........

PUN0013......... PUN0027......... PUN0028.........PUN0029.........PUN0031.........

pag 5pag 5pag 5pag 5pag 5pag 5pag 5pag 5pag 5 pag 5pag 5pag 5pag 5pag 5pag 5pag 6pag 6pag 6pag 6pag 6pag 6pag 6pag 6pag 6pag 6pag 6pag 6pag 6pag 7pag 7pag 7pag 7pag 7pag 7pag 8pag 8pag 8pag 8pag 8pag 8pag 8pag 9pag 9pag 9pag 9pag 24

pag 21 pag 21pag 22pag 22 pag 21

pag 19pag 19pag 19pag 19 pag 20pag 20 pag 20pag 20pag 20pag 20 pag 19 pag 20pag 20 pag 19pag 20pag 20pag 20 pag 21pag 21pag 21pag 22 pag 22pag 22 pag 21pag 21pag 21pag 21

pag 25pag 25 pag 13pag 13pag 13pag 13pag 13pag 13pag 13pag 14pag 14pag 14pag 14pag 14pag 14pag 14

pag 29pag 29pag 29

pag 13pag 13pag 13

PUN0032........PUN0033........PUN0034........PUN0035........PUN0038........PUN0046........PUN0048........PUN0049........PUN0050........PUN0051........PUN0127.........PUN0128.........PUN0130......... PUN0131......... PUN0132......... PUN0133......... PUN0134......... PUN0139......... PUN0140......... PUN0141......... PUN0150......... PUN0151......... PUN0152......... PUN0153......... PUN0164......... PUN0161......... PUN0163.........

RCM-14510.....RCM-14110..... RV-40012........RV-40014........ RV-40016........ RV-40018........RV-40020........RV-40022........RV-40024........RV-41012........RV-41014.........RV-41016.........RV-41018......... RV-41020........ RV-41022........ RV-41024........

S353-50.......... S354-25.......... S361-50...........

V122-14........... V122-16........... V122-18...........

pag 6pag 6pag 15pag 15pag 15pag 15pag 15pag 15pag 33pag 33pag 33pag 33pag 15pag 15pag 15pag 15

pag 33

V122-20........... V122-22........... V132-10........... V132-12........... V132-14........... V132-16........... V132-18........... V132-20........... VT-84410........ VT-84413........ VT-84510........ VT-84513........ V900-142........ V900-143........ V900-144........ V900-145........

W900-108.......

Page 37: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

35

Page 38: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Notes

Page 39: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit
Page 40: Pediatric Cannulae product catalog”етские... · product catalog. Table of Contents ... Sorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit

Manufactured by:Sorin Group USA14401 W. 65th WayArvada, CO - [email protected]

Manufactured by:Sorin Group ItaliaVia Statale 12 Nord, 8641037 Mirandola (MO) [email protected]