8
Find your ideal. Bio-Medicus ® Cannulae Family SIMPLY SUPERIOR CANNULAE

Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

Embed Size (px)

Citation preview

Page 1: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

Find your ideal.

Bio-Medicus® Cannulae FamilyS I M P l y S U P E R I o R C A N N U l A E

Page 2: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

Important Safety InformationCare and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

■ Adult Femoral Arterial and Venous Cannulae

■ Pediatric Arterial and Venous Cannulae

■ Percutaneous Cannula Kits

■ Multi-Stage Venous Cannulae

Medtronic has set the standard for quality and customer satisfaction for alternative access cardiopulmonary bypass cannulae.

Feature Benefit

Thin wall, polyurethane cannula body

Maximizes flow, minimizes pressure drop

Flat, wirewound construction Maximizes flexibility, resists kinking

Multiple side ports Maximizes flow rates

Smooth, tapered lumen Maximizes flow, minimizes turbulence

Radiopaque Facilitates visibility and positioning

Depth markings Indicates insertion depth

one piece, tapered introducer with guidewire port (Adult sizes only)

Facilitates insertion over 0.038 in guidewire

3⁄8 in or ½ in connector (Adult) ¼ in connector (Pediatric)

Adapts to most perfusion circuits

Bonded with Carmeda® BioActive Surface (optional)*

This non-leaching End Point Attached heparin biosurface mimics critical characteristics of the vascular endothelium to provide thromboresistance and biocompatbility

Flat ribbon wire reinforcement

.48 mm wall thicknessAdult Cannulae

Flat ribbon stainless steel wire reinforced cannulae resist kinking and maintain patency, yet offer the flow rates and flexibility needed for successful placement

through tortuous vessels.

.38 mm wall thicknessPediatric Cannulae

Bio-Medicus® Cannulae

Page 3: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

■■ These percutaneous cannula kits are designed to permit easy percutaneous insertion.

■■ The cannulae are ideally suited for direct surgical placement, using the surgeon’s preferred insertion technique.

■■ The thin-wall construction with high inside-to-outside diameter ratios notably improve flow rates; pressure drops are the lowest size-for-size of any cannulae.

■■ All percutaneous cannula kits feature sideports in the distal tip.

Venous Percutaneous Cannula Kits, non-vented connector

Catalog Code French Size Connector Tip Length With Carmeda® BioActive Surface (optional)

96600-015 15 Fr (5.0 mm) 3/8 in 50 cm CB96605-015

96600-017 17 Fr (5.7 mm) 3/8 in 50 cm CB96605-017

96600-019 19 Fr (6.3 mm) 3/8 in 50 cm CB96605-019

96600-021 21 Fr (7.0 mm) 3/8 in 50 cm CB96605-021

96600-023 23 Fr (7.7 mm) 3/8 in 50 cm CB96605-023

ArterialPercutaneous Cannula Kits, connector with vented connector

Catalog Code French Size Connector Tip Length With Carmeda® BioActive Surface (optional)

96530-015 15 Fr (5.0 mm) 3/8 in 18 cm CB96535-015

96530-017 17 Fr (5.7 mm) 3/8 in 18 cm CB96535-017

96530-019 19 Fr (6.3 mm) 3/8 in 18 cm CB96535-019

96530-021 21 Fr (7.0 mm) 3/8 in 18 cm CB96535-021

96540-023** 23 Fr (7.7 mm) ½ in 25 cm CB96540-023

** Non-vented ½ in connector with radiographic target; no hemostasis cap.

Percutaneous Cannula Kits

Venous and arterial percutaneous cannula kits include the following components necessary to achieve vascular access for cardiopulmonary bypass:

■■ One adult femoral (arterial or venous) cannula with introducer

■■ One 18 ga introducer needle■■ Two stepped vessel dilators :

8/10 Fr and 12/14 Fr■■ One 0.038 in diameter guidewire■■ One #11 blade scalpel■■ One hemostasis cap

Page 4: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

Multi-Stage Venous Cannulae with Percutaneous Kit

Important Safety InformationCare and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

Positioning the tip of the cannula well into the SVC optimizes drainage of the entire venous circulation by accessing the SVC, atrium and IVC.

The extended length introducer with new, smoother transition zone, promotes ease of percutaneous femoral vein cannulation and advancement through tortuous venous anatomy.

Depth marks allow the surgeon to visualize the length of the introducer beyond tip of the cannula body

3⁄8 in non-vented connector

Tip taper location indicator

Page 5: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

20

01 2 3 4 5 6

40

60

80

100

120

140

160

180

Pres

sure

loss

(mm

Hg)

Multi-Stage Bio-Medicus®

Pressure Drop vs. Flow

Flow rate (L/min of water) at room temperature

19 Fr

21 Fr

25 Fr

Available in 19, 21 and 25 Fr sizes to accommodate different patient size requirements

60 cm tip length accommodates femoral insertion of the cannula tip into the SVC with additional side holes distributed through the atrium and IVC

Cannula depth marks allow the surgeon to visualize the insertion depth of the cannula body

VenousMulti-Stage Cannulae with Percutaneous Kit

Catalog Code French Size Tip Length No. of Baskets

96880-019 19 Fr (6.3 mm) 60 cm 6

96880-021 21 Fr (7.0 mm) 60 cm 7

96880-025 25 Fr (8.3 mm) 60 cm 8

Multiple side holes provide additional sites for drainage, improving or maintaining blood flow

Improved cannula transition provides ease of insertion

Additional dilator now included to stretch tissue/vessel to approximate the cannula size

Elongated taper allows the introducer to dilate the vessel over a longer distance during insertion

Extended length allows the introducer to follow the guidewire into the patient vasculature to aid in cannula insertion

Page 6: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

VenousPressure Drop vs. Flow

ArterialPressure Drop vs. Flow

Pres

sure

loss

(mm

Hg)

Pres

sure

loss

(mm

Hg)

20

60

100

140

180

0 1 2 3 4 5 6 7

23 Fr

25 Fr

27 Fr

29 Fr

15 F

r

17 F

r

19 Fr

21 Fr

40

80

120

160

200

2040

60

80

100

120

140

160

180

200

0 1 2 3 4 5 6 7

15 F

r

17 Fr

19 Fr

21 Fr

23 Fr

Flow rate (L/min of water) at room temperature Flow rate (L/min of water) at room temperature

ArterialAdult Femoral Cannulae with introducer, 3⁄8 in vented connector

Catalog Code French Size Tip Length With Carmeda® BioActive Surface (optional)

96570-015 15 Fr (5.0 mm) 18 cm CB96570-01596570-017 17 Fr (5.7 mm) 18 cm CB96570-01796570-019 19 Fr (6.3 mm) 18 cm CB96570-01996570-021 21 Fr (7.0 mm) 18 cm CB96570-021

VenousAdult Femoral Cannulae with introducer, ½ in non-vented connector

Catalog Code French Size Tip Length With Carmeda® BioActive Surface (optional)

96370-023 23 Fr (7.7 mm) 50 cm CB96345-02396370-025 25 Fr (8.3 mm) 50 cm CB96345-02596370-027 27 Fr (9.0 mm) 50 cm CB96345-02796370-029 29 Fr (9.7 mm) 50 cm CB96345-029

VenousAdult Femoral Cannulae with introducer, 3⁄8 in non-vented connector

Catalog Code French Size Tip Length With Carmeda® BioActive Surface (optional)

96670-015 15 Fr (5.0 mm) 50 cm CB96670-01596670-017 17 Fr (5.7 mm) 50 cm CB96670-01796670-019 19 Fr (6.3 mm) 50 cm CB96670-01996670-021 21 Fr (7.0 mm) 50 cm CB96670-021

Standard Insertion KitCatalog Code Contents 1 ea Scalpel, #11 blade96550 1 ea Introducer needle, 18 ga

1 ea Vessel dilator, 8-10 Fr1 ea Vessel dilator, 12-14 Fr1 ea Guidewire, 0.038 in x 180 cm1 ea Catheter tip, syringe 60 cc

Adult Cannulae

■■ These adult cannulae have a long-standing reputation as the alternative access cannulae of choice for use with the Bio-Pump® Centrifugal Blood Pump.

■■ The unique flat wirewound, polyurethane construction of the cannula allows very thin wall construction—thereby maximizing flow rates and cannula flexibility.

■■ The cannula can be inserted percutaneously over a 0.038 in guidewire or under direct visualization.

■■ All adult models feature a 3⁄8 in or ½ in connector.

Page 7: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

20

40

60

80

100

120

140

160

180

200

20

40

60

80

100

120

140

160

180

200

0 .50 1.00 1.50 2.00

8 Fr

10 Fr

12 Fr

14 Fr

0 .50 1.00 1.50 2.00

8 Fr

10 Fr

12 Fr

14 Fr

VenousPressure Drop vs. Flow

ArterialPressure Drop vs. Flow

Flow rate (L/min of water) at room temperature Flow rate (L/min of water) at room temperature

Pres

sure

loss

(mm

Hg)

Pres

sure

loss

(mm

Hg)

Important Safety InformationCare and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.

VenousPediatric Cannulae, ¼ in non-vented connector

Catalog Code French Size Tip Length Overall Length With Carmeda® BioActive Surface (optional)

96830-008 8 Fr (2.7 mm) 10 cm 19 cm CB96835-008

96830-01 0 10 Fr (3.3 mm) 10 cm 19 cm CB96835-01 0

96830-01 2 12 Fr (4.0 mm) 11 cm 19 cm CB96835-01 2

96830-01 4 14 Fr (4.7 mm) 12 cm 19 cm CB96835-01 4

ArterialPediatric Cannulae, ¼ in non-vented connector

Catalog Code French Size Tip Length Overall Length With Carmeda® BioActive Surface (optional)

96820-008 8 Fr (2.7 mm) 10 cm 19 cm CB96825-008

96820-01 0 10 Fr (3.3 mm) 10 cm 19 cm CB96825-01 0

96820-01 2 12 Fr (4.0 mm) 11 cm 19 cm CB96825-01 2

96820-01 4 14 Fr (4.7 mm) 12 cm 19 cm CB96825-01 4Standard Insertion Kit

Catalog Code Contents 1 ea Scalpel, #11 blade96550 1 ea Introducer needle, 18 ga

1 ea Vessel dilator, 8-10 Fr1 ea Vessel dilator, 12-14 Fr1 ea Guidewire, 0.038 in x 180 cm1 ea Catheter tip, syringe 60 cc

Pediatric Cannulae

■■ These pediatric cannulae are for use in pediatric patients requiring alternative access for cardiopulmonary bypass.

■■ The cannulae also feature thin wall, flat wirewound polyurethane construction in order to maximize flow rates and flexibility.

■■ The pediatric models feature flexible, round tip plastic introducers that facilitate insertion under direct visualization.

■■ All pediatric models feature a ¼ in non-vented connector.

■■ Pediatric venous cannulae contain radiographic target at tip.

Page 8: Bio-Medicus Cannulae Family - arcos.com.uyarcos.com.uy/pdf/productos/28/995_bio_medicus_cannulae_family.pdf · Bio-Medicus® Cannulae Family ... Care and caution should be taken to

World HeadquartersMedtronic, Inc. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Tel: (763) 514-4000 Fax: (763) 514-4879 Medtronic USA, Inc. Toll-free: 1 (800) 328-2518(24-hour technical support for physicians and medical professionals)

EuropeMedtronic International Trading Sàrl Route du Molliau 31 Case postale CH-1131 Tolochenaz Switzerland Tel: 41.21.802.7000 Fax: 41.21.802.7900

Asia PacificMedtronic International, Ltd. 16/F Manulife Plaza The Lee Gardens, 33 Hysan Avenue Causeway Bay Hong Kong Tel: (852) 2891 4456 Fax: (852) 2891 6830 [email protected]

CanadaMedtronic of Canada Ltd. 6733 Kitimat Road Mississauga, Ontario L5N 1W3 Canada Tel: (905) 826-6020 Fax: (905) 826-6620 Toll-free: 1 (800) 268-5346

Latin AmericaMedtronic USA, Inc. Doral Corporate Center II 3750 NW 87th Avenue Suite 700 Miami, FL 33178 USA Tel: (305) 500-9328 Fax: (786) 709-4244

LifeLine CardioVascular Technical Support Tel: (877) 526-7890 Tel: (763) 526-7890 Fax: (763) 526-7888 E-mail: [email protected]

UC2

0090

4113

b EN

© M

edtr

onic

, Inc

. 201

1. A

ll Ri

ghts

Res

erve

d. P

rinte

d in

USA

www.medtronicMICS.comwww.medtronic.com

*Manufactured under license from Carmeda AB, Sweden. Carmeda is a registered trademark of Carmeda AB. Bio-Medicus and Bio-Pump are registered trademarks of Medtronic, Inc.

Important Safety InformationCare and caution should be taken to avoid damage to vessels and cardiac tissue during cannulation or other cardiac surgery procedures. For a listing of indications, contraindications, precautions and warnings, please refer to the Instructions for Use. Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.