AIR CONDITIONING SYSTEMCOOLING ONLY [50Hz]
PCS0911A
CEILING MOUNTED CASSETTE TYPE
FHC18NUV1 FHC21NUV1 FHC26NUV1R18NUV1 R21NUV1 R26NUV1 / Y1Outdoor unit
Indoor unit
18,0005.3
4,560
21,0006.2
5,290
26,0007.6
6,550
2 2.5 3
kW
Btu/h
kcal/h
CEILING SUSPENDED TYPE
OUTDOOR UNIT
R18NUV1 R21NUV1 R26NUV1 / Y1
DUCT CONNECTION
LOW STATIC PRESSURE TYPE
FDBG18PUV1 FDBG21PUV1 FDBG26PUV1
FH21NUV1 FH26NUV1R21NUV1 R26NUV1 / Y1
R18NUV1 R21NUV1 R26NUV1 / Y1
HP
Cooling only
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
FDMG26PUV1R26NUV1 / Y1
MIDDLE STATIC PRESSURE TYPE
Capacity *1
The values given for2 HP–6 HP is for FHC type,6.5 HP–7 HP is for FDMG type.
*1. Note : Rated cooling capacities are based on the following conditions: Return air temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal)
FHC30NUV1R30NUV1 / Y1
30,0008.8
7,570
3.5
R30NUV1 / Y1
FH30NUV1R30NUV1 / Y1
FDMG30PUV1R30NUV1 / Y1
FDMG26NUV1R26NUV1 / Y1
FDMG30NUV1R30NUV1 / Y1
The match for tastefully designed offices and stores.
People are drawn to beaut i fu l ly designed stores that express the latest . People work best in off ices
imbued with funct ional beauty.
Daik in ’s SkyAir is the choice to br ing high qual i ty air condi t ioning to stores and off ices l ike th is.
Thanks to i ts many advantages such as quiet operat ion, ease of use and f lexible instal lat ion, the SkyAir
enjoys an excel lent reputat ion throughout the wor ld wherever i t is used.
1
FHC42NUV1R42NUY1
FHC48NUV1R48NUY1
42,00012.3
10,600
48,00014.1
12,100
5 6
CEILING MOUNTED CASSETTE TYPE
FH42NUV1R42NUY1
FH48NUV1R48NUY1
51,00015.0
12,900
6.5
56,00016.4
14,100
7
R51NUY1R48NUY1R42NUY1 R56NUY1
FDMG42PUV1 FDMG48PUV1R42NUY1 R48NUY1
FDMG51PUV1R51NUY1
FDMG56PUV1R56NUY1
FHC36NUV1R36NUV1 / Y1
36,00010.6
9,100
4
R36NUV1 / Y1
FH36NUV1R36NUV1 / Y1
FDMG36PUV1R36NUV1 / Y1
FDMG42NUV1 FDMG48NUV1R42NUY1 R48NUY1
FDMG51NUV1R51NUY1
FDMG56NUV1R56NUY1
FDMG36NUV1R36NUV1 / Y1
CEILING SUSPENDED TYPE
DUCT CONNECTION TYPE
The indoor uni t is instal led inside the cei l ing and ducts discharge air in any direct ion. Comfort is provided without even knowing that an air condi t ioner is instal led.
Simple design and quiet operat ion auto-swing air f low br ings comfort to each and every corner of the room. Instal lat ion and maintenance are easy.
Simple design and quiet operat ion auto-swing air f low br ings comfort to each and every corner of the room. Instal lat ion and maintenance are easy.
The indoor uni t is instal led inside the cei l ing and ducts discharge air in any direct ion. Comfort is provided without even knowing that an air condi t ioner is instal led.
This uni t is instal led at center cei l ing. Air is b lown in four direct ions to br ing comfort . Operat ion is quiet .
This uni t is instal led at center cei l ing. Air is b lown in four direct ions to br ing comfort . Operat ion is quiet .
2
Quiet, decor-blending form and easy installation
3
CEILING MOUNTED
CASSETTE TYPE
BRC7C613W
A signal receiver must be added to the indoor unit.
Note: Remote controller cable not included. Cables must be procured locally.
Wireless remote controller and signal receiver unit are sold as a set.
Wired LCD remote controller
Wireless LCD remote controller
BRC1C61
FHC18NU–48NUCooling only
Signal receiver unit (Installed type)
FHC-NU
Accessory required for indoor unit
Option
*1 *2
Sw
ing
pat
tern
sel
ectio
n
Sw
itcha
ble
fan
spee
d
Aut
o sw
ing
Pro
gra
mm
e "D
ry"
Hig
h ce
iling
ap
plic
atio
n
Tim
er s
elec
tor
Dra
in p
ump
mec
hani
sm
Pre
cha
rged
for
up to
15
m
Long
-life
filte
r
Mou
ld r
esis
tant
trea
tmen
t fo
r fil
ter
Filte
r si
gn
Cei
ling
soi
ling
pre
vent
ion
Ultr
a lo
ng-li
fe fi
lter
Hig
h-ef
ficie
ncy
filte
r
Fres
h ai
r in
take
kit
Aut
o-re
star
t
Two
sele
ctab
le
tem
per
atur
e-se
nsor
s
Cooling only
MouldpreventionComfort Work & Servicing Control
features Options OthersFeature
Features
*1Applicable when wired remote controller is used*2Applicable to R36NU–R48NU outdoor units
• • • • • • • • •• • • • • •Model
•
42/36dB(A)FHC36NU
(220V)
High Low
Sound level
PE
fin
4
Optimal comfort and convenience assured by 3 air discharge modes
Compact body and quiet operation
Air discharge opening increases flow without increasing wind speed, hence discharged air reaches farther than before.
Indoor units use anaerodynamically designedDiffuser Turbo Fan
Wide air distribution
Suitable for high ceilings
Programme "Dry"
Switchable fan speed: High/Low
Multi-Flow System
Two selectable temperature-sensors
Unified square panelsAll models from the 18NU to 48NU use the same size panel. Multiple unit installations maintain a physical uniformity that is aesthetically pleasing and make it easier to plan ceiling lighting systems and to design interiors.
Quick and easy to install
Both indoor unit and wired remote controller (option) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control.This feature require initial setting by the installer.
Draft resistance has been reduced by incorporating, into a single unit, an impeller and a diffuser to control air flow inside the unit. The Diffuser Turbo Fan is both quiet during operation and compact.
All models suspended without lift
Installable in any direction
Provided with drain pump mechanism
The high-performance filter and other options are easily clipped into place. There is no need for a screwdriver.
Easy installation of options
Just 240 mm high. Installable in tight ceiling spaces (18NU–26NU)
Easy height adjustment
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
1 pattern4-way flow
4 pattern3-way flow
3 pattern2-way flow
" " denotes piping direction. " " denotes sealing member for air discharge outlet (option) .
Number of air discharge outlets used
18NU–26NU4-wayflow
3-wayflow
2-wayflow
4-wayflow
3-wayflow
2-wayflow
30NU–48NU
2.7 m3.0 m3.5 m
3.0 m3.3 m3.5 m
3.5 m3.8 m-
3.2 m3.6 m4.2 m
3.6 m4.0 m4.2 m
4.2 m4.2 m-
Note: Operation sound increases when using 2-way or 3-way flow.
Air direction can be selected according to installation.
StandardCeiling height
High ceiling High ceiling
Criteria for ceiling height and number ofair discharge outlets
Note: For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s).
26NU 35 30
18NU 33 29
950 mm
950
mm
Same for all models
Indoor unit High Low
36NU 42 36
21NU 35 30
42NU 42 3648NU 42 36
Diffuser
Blade
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
*When the thermostat turns off.
Note: Initial settings are for standard ceiling height and 4-way flow. High ceiling settings 1 and 2 are set from the remote controller.
Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets.
240 mm *1 245 mm *2
750 mm
*1 298 mm high with 30NU–48NU*2 303 mm high with 30NU–48NU
Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height.
Note: Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller.
Air directionDesired situation
Auto-swing
5-levelsair directionsetting
Draft prevention(In heating mode)
Auto air direction control
Settable to 5 different levels between 10° and 40°
Settable to 5 different levels between 10° and 65°
Settable to 5 different levels between 30° and 65°
Auto-swing between10° and 40°
Auto-swing between10° and 65°
Auto-swing between30° and 65°
When drafts are unwanted For gentle drafts(Ceiling is soiled.) When ceilings must be kept spotlessDraft prevention setting Standard setting Setting to prevent soiling of ceiling
At heating startup and thermo OFF*, air discharge is automatically set to a near horizontal 10˚ to prevent direct exposure to cool air drafts.
The air direction is set automatically to the memorised position of the previous air direction. (Initial setting is 65˚ for heating and 30˚ for cooling.)
At heating startup and thermo OFF*, air discharge is
automatically set to 30˚ to prevent both direct exposure to cool air drafts and contact with ceilings.
Super Cassette
1
2
1
2
(m)2.7
3
(m)3.2
4 (m)32101234 (m)
Conventional model
2.5 m/sec2.5 m/sec
2.0 m/sec2.0 m/sec
1.5 m/sec1.5 m/sec
1.0 m/sec1.0 m/sec
0.5 m/sec0.5 m/sec
Air discharge distribution comparison•42NU
dB(A)(220V)
30NU 39 34
Upgrade to a quiet and compact system.
5
CEILING SUSPENDED TYPE
46/40dB(A)FH36NU
(220V)
High Low
Sound level
BRC7NU66
A signal receiver must be added to the indoor unit.
Note: Remote controller cable not included. Cables must be procured locally.
Wireless remote controller and signal receiver unit are sold as a set.
Wired LCD remote controller
Wireless LCD remote controller
BRC1NU61
FH21NU–48NUCooling only
Signal receiver unit (Installed type)
• • • • • • *1 ••Cooling only
MouldpreventionComfort Work &
Servicing OptionsControl featuresFeature
Features
*1Applicable to R36NU–R48NU outdoor units
Pre
cha
rged
for
up to
15
m
Long
-life
filte
r
Mou
ld r
esis
tant
trea
tmen
t fo
r fil
ter
Aut
o-re
star
t
•
Others
PE
fin
Model Sw
itcha
ble
fan
spee
d
Aut
o sw
ing
Pro
gra
mm
e "D
ry"
Tim
er s
elec
tor
Mou
ld p
roof
ing
d
rain
pan
Accessory required for indoor unit
Option
FH-NU
6
4421NU
26NU 44
Quiet operationSpreads comfortable air throughout the room
Installation flexibility for freedom of design
Wide air discharge openings produce a spreading 100° airflow
Air is blown up to 50° in the downward direction.
Reduced edge space, flexible installation
Uniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints.
All wiring and internal servicing done from below the unit
Installable on ceilings 3.5 m high
Switchable fan speed: High/Middle/Low
Programme "Dry"
Indoor unit High Low
36NU 46 4030NU 45 40
42NU 48 4248NU 49 43
*Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case.
Weight of all models reduced (down 10% compared with previous models). Transfer and installation work is less arduous.
Improved-oil resistant grilleOil-resistant plastic is used for the air discharge grille. This improves durability in restaurants and other similar environments.
Absence of bristles minimises clinging dirt and simplifies cleaning.
It is easy to wipe dirt off the flat side and lower surfaces of the unit.
The unit fits more snugly into tight spaces.
Pipes more easily rigged, tooPlastic panels are used to conceal piping holes. Holes can be easily punched out without requiring special tools.
For all maintenance tasks, access is from bottom surface
Easier to maintainLong-life filter lasts about half year * maintenance not required
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments.
1,590 mm30 mm or more
30 mm or more
* For dust concentration of 0.15 mg/m3
For 48NU indoor unit
Non-dew flap without bristles
Easy-clean, flat surfaces
100°
50°
195
1,590
42NU 48NU
680
1,160 1,400
(mm)
Sound operation has been reduced on the exposed ceiling suspended type unit.
Height
Indoor unit
WidthDepth
Uses quiet stream fanand other quiet technologies.
Turbulent flow is produced
Non-dew flap
Straightening vane
Quiet stream fan
26NU 36NU30NU21NU
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Auto-swing (up&down) brings comfort to the room.
4040
(220V) dB(A)
Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria.
DUCT CONNECTION
MIDDLE STATIC PRESSURE TYPE
Accessory required for indoor unitOption
45/37dB(A)FDMG36PU
(220V)
High Low
Sound level
FDMG26PU–56PUFDMG26NU–56NU
Cooling only
FDMG-NUFDMG-PU
Quiet operation
Switchable fan speed: High/Middle/Low
Drain pipe connection can be done inside the unit. Coolant and drain pipe outlets are at the same opening.
FDMG26PU
Indoor unit
FDMG42PU
FDMG36PU
FDMG48PU
FDMG56PU
FDMG51PU
High
4645
42
46
4747
38FDMG30PU 44 36
LOW
3737
37
3737
Air conditioner295 mm
Ordinary duct(procured locally)
Ordinary duct(procured locally)
Air discharge Air intake305 mm or more
(FDMG26NU–56NU)
Superior freedom of layout
Unit can be mounted in the ceiling and air can be delivered freely by duct.
The duct system allows the efficient location of discharge outlets in accordance with the room layoutMiddle static pressure type, usable in a larger than standard spaceDuct connection is simpler with standard rear intake chambers
Work & Servicing
Pre
cha
rged
for
up to
15
m
• •Cooling only
Comfort Control features OthersFeature
Features
Aut
o-re
star
t
*2
Two
sele
ctab
le
tem
per
atur
e-se
nsor
s
*1 •
PE
fin
Model Sw
itcha
ble
fan
spee
d
*1Applicable when wired remote controller is used (FDMG-PU)*2Applicable to R36NU–R51NU outdoor units
(220V) dB(A)
Digital remote controller
KRC47-2A KRC47-1A
Remote controller
FDMG36PU
Wired LCD remote controller
Wireless remote controller and signal receiver unit are sold as a set.
Signal receiver unit
(Separate type)BRC4C64
A signal receiver must be added to the indoor unit.
Note: Remote controller cable not included. Cables must be procured locally.
Wireless LCD remote controller
BRC1C61
For FDMG-NU
For FDMG-PU
7
(FDMG26PU–56PU is switchable fan speed: High/Low)
8
Accessory required for indoor unitOption
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Ventilation grille
Door-installedventilation grille
Ventilation grille
Wall-installedventilation grille
Under-door cutout
Under-door cutoutWhen air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Ventilates air through the partitioning wall. (See right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
(This feature also applies to duct connection middle static pressure type.)
Ideal for quiet, beautiful living spacesSuitable for condominiums and apartments, houses and hotels
DUCT CONNECTION
LOW STATIC PRESSURE TYPE
FDBG18PU–26PUCooling only
FDBG-PU
CompactSmall, lightweight, and easy-to-install indoor unit.
Quiet operation
FDBG18PU 41 38FDBG21PU 43 40FDBG26PU 43 40
Indoor unit High Low
43/40dB(A)FDBG26PU
(220V)
High Low
Sound level
Work & Servicing
Pre
cha
rged
for
up to
10
m
• •Cooling only
Comfort Control features OthersFeature
Features A
uto-
rest
art
•
Two
sele
ctab
le
tem
per
atur
e-se
nsor
s
*1 •
PE
fin
Model Sw
itcha
ble
fan
spee
d
*1Applicable when wired remote controller is used
(220V) dB(A)
Suction chamberAir filter[Duct connection]
To prevent increased operation sound, avoid installing the air suction grille directly below the suction chamber.
or moreor moreor more
Wired LCD remote controller
Wireless remote controller and signal receiver unit are sold as a set.
Signal receiver unit
(Separate type)BRC4C64
A signal receiver must be added to the indoor unit.
Note: Remote controller cable not included. Cables must be procured locally.
Wireless LCD remote controller
BRC1C61
Fitted with wide inlet fan (Applies to R26NU–51NU)
Curved Super Aero Grille restricts the spread of exhaust gas and fits in the same space as conventional outdoor units.
Fitted with Super Aero Grille (Applies to R26NU–51NU)
Equipped with scroll compressor for quiet operation
Even less operation sound
Wide inlet fan
Allowed refrigerant pipe length and level difference
Max. length Max. leveldifference
Pre charged*1
R26NU
R36NU 30 m(Equivalent length 50 m)
30 m(Equivalent length 50 m)
30 m(Equivalent length 50 m)
30 m(Equivalent length 50 m)R18NU
R21NU
30 m(Equivalent length 50 m)
30 m(Equivalent length 50 m)
R42NU
R48NU
R51NU
Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.
(Applies to R36NU–56NU)
Construction
Non-treated fin
PE fin
Aluminium
AluminiumCorrosion resistantacrylic resin
Hydrophilic film
500
50
(mm)
50 m(Equivalent length 70 m)R56NU
30 m(Equivalent length 50 m)
9
OUTDOOR UNIT
Quiet Operation
Fully shaped aerodynamic propellers are designed to push air with a large wing surface. This provides both high blow volume and quiet operation with minimal turbulence.
Slim-design and low-profile compact outdoor units (Applies to R26NU–51NU)
Compact
Compactly designed outdoor unit with interior layout optimised for the smooth airflow.
Smooth running, minimal vibration, low operating sound.
To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air.
Pre charged for up to 15 metres (Applies to R36NU–51NU)
Installation and maintenance
If refrigerant piping length does not exceed 5m (R56NU), 10m (R18NU,R21NU, R26NU), 15m (R36NU, R42NU, R48NU, R51NU), there is no need for on-site gas charging.
Heat exchange fins provided with anti-corrosion treatment
Takes installation environment into consideration
Durability
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
4-direction piping offers greater layout freedom (Applies to R26NU–56NU)
(Applies to R26NU–36NU)
Piping can be run from the front, bottom, right or rear surface according to how the unit is installed.
10 m
15 m
10 m
10 m
15 m
15 m
5 m
15 m
20m
R30NU 30 m(Equivalent length 50 m)10 m 20m
20 m
15 m
15 m
20 m
20 m
30 m
20 m
Outdoor unit Sound level
R36NUV1R36NUY1
R30NUY1
5557R30NUV1
R42NUY1 57R48NUY1
R18NUV1
R21NUV1
59
4954
R51NUY1 59
R36NU R42NU R48/51NUR26/30NU
(In case of V1: 220V, Y1: 380V) dB(A)
R18NU R21NU
10
Air discharge direction angle can be set (fixed setting)
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room.
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
Sanitary filter has mould resistant treatment.
Mould proofing maintains hygiene by preventing growth in highly humid conditions.
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
If refrigerant piping length does not exceed 15 m, there is no need for on-site gas charging. (Applies to R36NU–51NU)
If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.
Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner.
High setting provides maximum reach while low setting minimises drafts.
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out.
Abundance of functions that provide comfortable air-conditioning in stores and offices. See the list of main functions given on the page introducing each indoor unit.
Auto-swing
Programme "Dry"
Timer selector
Mould resistant treatment for filter
Mould proofing drain pan
Drain pump mechanism
Pre charged for up to 15 metres
Auto-restartSwitchable fan speed
PE fin
Maintenance is not required for one year (two years when a ceiling mounted cassette type is used).
Long-life filter
(1) Air direction range in standard position
(2) Air direction range in draft prevention position
(3) Air direction range in ceiling soiling prevention position
(draft prevention, standard, ceiling soiling prevention)
Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.
You can freely set 3 air discharge positions by remote controller.
Swing pattern selection
Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.
High-ceiling application
The filter sign warns you when it is time to clean the filter.
*When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
Filter sign
Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.
Ceiling soiling prevention function
Two types are available: 65% and 90% colorimetry.
High-efficiency filter unit
Requires no maintenance for about 4 years* (10,000 h) in stores and offices. * For dust concentration of 0.15 mg/m3
Ultra long-life filter
You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.
Fresh-air intake kit
C o m f o r t
Mould prevention
O t h e r s
Work and Servicing
Control features
Options
*Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending.
Note:
Hermetically sealed scroll type
2030 (equivalent length 50 m)
21 to 46
Cooling capacity 1a/1b
kWBtu/h
kcal/hkWPower consumption 1a/1b
°CDB
°CWBOperation range
ModelName
Indoorunit
Indoor unit
Outdoor unit
Dimensions(HXWXD)
Colour
mmmm
Sound level (H/L) (220V) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2, 3 dB(A)Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weightkgkgUnit
Decoration panel
Airflow rate (H/L) m3/mincfm
Outdoorunit
Colour
mm
Operation range
Max. interunit piping length mmMax. installation level difference
kWMotor outputCompressor Type
CEILING MOUNTED CASSETTE TYPE
White
Ivory
Both liquid and gas piping
----------
14 to 28
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Note : 1Rated cooling capacities are based on the following conditions: 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1bIndoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3In case of V1: 220V, Y1: 380V.
Ivory Hermetically sealed scroll type
CEILING SUSPENDED TYPE
20
Cooling capacity 1a/1b
kWBtu/h
kcal/hkWPower consumption 1a/1b
ModelName
Indoorunit
Indoor unit
Outdoor unit
Sound level (H/L) (220V) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2, 3 dB(A)Dimensions (HXWXD) mmMachine weight kg
Machine weight kg
Operation range °CDB
Operation range °CWB
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Airflow rate (H/L) m3/mincfm
Outdoorunit
Colour
mm
Dimensions (HXWXD)
Colour
mm
Max. interunit piping length mmMax. installation level difference
kWMotor outputCompressor Type
Note : 1Rated cooling capacities are based on the following conditions: 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1bIndoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3In case of V1: 220V, Y1: 380V.
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
White
14 to 28
21 to 46
Both liquid and gas piping
30 (equivalent length 50 m)
36,500/36,00010.7/10.6
9,200/9,100
46/40195X1,590X680
35
3.002.0
1,170X900X32081 (V1), 79 (Y1)
(Charged for 15 m)
I.Do/ 20XO.Do/ 26
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
4.06/4.06
32-34/22-241,129-1,200/776-847
55
36FH36NUV1R36NUV1R36NUY1
30,400/30,0008.9/8.8
7,670/7,570
45/40195X1,400X680
32
2.52.3
770X900X32070 (V1), 69 (Y1)
(Charged for 10 m)
I.Do/ 20XO.Do/ 26
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
3.48/3.48
26-27/22-23917-953/776-811
30FH30NUV1R30NUV1R30NUY1
42,700/42,00012.5/12.3
10,800/10,600
48/42195X1,590X680
35
3.752.4
1,170X900X32087
(Charged for 15 m)
I.Do/ 20XO.Do/ 26
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
4.83/4.83
38-40/23-251,341-1,412/811-882
57
R42NUY1
42FH42NUV1
49,100/48,00014.4/14.1
12,400/12,100
49/43195X1,590X680
35
4.502.6
1,345X900X32092
(Charged for 15 m)
I.Do/ 20XO.Do/ 26
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
5.50/5.50
42-44/24-261,482-1,553/847-917
59
R48NUY1
48FH48NUV1
15
Hermetically sealed rotary type
3.002.0
1,170X900X32081 (V1), 79 (Y1)
(Charged for 15 m)
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
55
36FHC36NUV1
R36NUV1R36NUY1
33/241,164/847
288X840X840
28
42/36
40X950X950
5
I.Do/ 25XO.Do/ 32
36,500/36,00010.7/10.6
9,200/9,1004.04/4.04
2.52.3
770X900X32070 (V1), 69 (Y1)
(Charged for 10 m)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
30FHC30NUV1
R30NUV1R30NUY1
28/21988/741
288X840X840
28
39/34
40X950X950
5
I.Do/ 25XO.Do/ 32
30,400/30,0008.9/8.8
7,670/7,5703.45/3.45
3.752.4
1,170X900X32087
(Charged for 15 m)
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
57
R42NUY1
42FHC42NUV1
33/241,164/847
42/36288X840X84040X950X950
285
I.Do/ 25XO.Do/ 32
42,700/42,00012.5/12.3
10,800/10,6004.79/4.79
4.502.6
1,345X900X32092
(Charged for 15 m)
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
59
R48NUY1
48FHC48NUV1
33/241,164/847
42/36288X840X84040X950X950
285
I.Do/ 25XO.Do/ 32
49,100/48,00014.4/14.1
12,400/12,1005.49/5.49
Ivory white
18FHC18NUV1
R18NUV1
1.71.20
49540X750X270
42
(Charged for 10 m)
o/ 6.4o/ 15.9
o/ 18.0 (Hole)I.Do/ 25XO.Do/ 32
15/11529/388
230X840X840
24
33/29
40X950X950
5
18,100/18,0005.3/5.3
4,580/4,5602.03/2.02
Hermetically sealed rotary type
21FHC21NUV1
R21NUV1
2.21.50
54685X800X300
61
(Charged for 10 m)
o/ 6.4o/ 15.9
o/ 18.0 (Hole)I.Do/ 25XO.Do/ 32
19/14670/494
230X840X840
24
35/30
40X950X950
5
21,200/21,0006.2/6.2
5,340/5,2902.46/2.45
26FHC26NUV1
R26NUV1R26NUY1
57 57
2.52.3
770X900X32070 (V1), 69 (Y1)
(Charged for 10 m)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)I.Do/ 25XO.Do/ 32
19/14670/494
230X840X840
24
35/30
40X950X950
5
26,300/26,0007.7/7.6
6,630/6,5503.07/3.07
26FH26NUV1R26NUV1R26NUY1
57 57
2.52.3
770X900X32070 (V1), 69 (Y1)
(Charged for 10 m)
I.Do/ 20XO.Do/ 26
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
44/40
26,300/26,0007.7/7.6
6,630/6,5503.10/3.10
22-23/9-20776-811/317-706
195X1,160X68026
15
21FH21NUV1
R21NUV1
2.21.50
54685X800X300
61
(Charged for 10 m)
I.Do/ 20XO.Do/ 26
o/ 6.4o/ 15.9
o/ 18.0 (Hole)
21,200/21,0006.2/6.2
5,340/5,290
22-23/9-20776-811/317-706
44/40195X1,160X680
26
2.72/2.71
Ivory white
11
°CDB
°CWB
kWHermetically sealed rotary type
1.71.13
49540X750X270
42
2.21.55
54685X800X300
61
1530 (equivalent length 50 m)
(Charged for 10 m) (Charged for 10 m)
o/ 6.4o/ 15.9
o/ 6.4o/ 15.9
o/ 18.0 (Hole) o/ 18.0 (Hole)
Both liquid and gas piping
2.52.3
770X900X32070 (V1), 69 (Y1)
(Charged for 10 m)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
20
57
21 to 46
2.12/2.11 2.73/2.72 3.33/3.33
3/4B (I.Do/ 21.6XO.Do/ 27.2)
----------13/11
458/388
41/38260X900X580
25
18/15635/529
43/40260X1,300X580
32
18/15635/529
43/40260X1,300X580
3214 to 28
Ivory white Ivory
Cooling capacity 1a/1b
kWBtu/h
kcal/hkWPower consumption 1a/1b
Operation range
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD) mmSound level (H/L) (220V) 2 dB(A)
2.0 2.0 2.0Rated external static pressure mmH2O
Refrigerant charge (R-22) kg
Sound level 2, 3 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H/L) m3/mincfm
Outdoorunit
mm
Operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
R18NUV1 R21NUV1R26NUV1R26NUY1
Colour
Power supply
Motor outputCompressor Type
DUCT CONNECTION LOW STATIC PRESSURE TYPE
Note : 1Rated cooling capacities are based on the following conditions: 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1bSuction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3In case of V1: 220V, Y1: 380V.
18FDBG18PUV1
21 26FDBG21PUV1 FDBG26PUV1
V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz18,100/18,000
5.3/5.34,580/4,560
21,200/21,0006.2/6.2
5,340/5,290
26,300/26,0007.7/7.6
6,630/6,550
Hermetically sealed rotary type
3/4B (I.Do/ 21.6XO.Do/ 27.2)
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Note : 1Rated cooling capacities are based on the following conditions: 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 1bSuction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal). 2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3In case of V1: 220V, Y1: 380V.
----------
Hermetically sealed scroll type
Both liquid and gas piping
Cooling capacity 1a/1b
kWBtu/h
kcal/hkWPower consumption 1a/1b
°CDB
°CWBOperation range
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD) mmSound level (H/L) (220V) 2 dB(A)
Refrigerant charge (R-22) kgSound level 2, 3 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H)Fan m3/mincfm
Outdoorunit
mm
Operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
30 (equivalent length 50 m)
Ivory
Colour
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
kWMotor outputCompressor Type
14 to 28
21 to 46
36,500/36,00010.7/10.6
9,200/9,100
305X1,550X68052
2.0(Charged for 15 m)
1,170X900X32081 (V1), 79(Y1)
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
371,306
45/37
3.00
55
36
FDMG36NUV1R36NUV1R36NUY1
30,400/30,0008.9/8.8
7,670/7,570
305X1,550X68051
2.3(Charged for 10 m)
770X900X32070 (V1), 69 (Y1)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
3.46/3.46
341,200
44/36
2.5
30
FDMG30NUV1R30NUV1R30NUY1
20
42,700/42,00012.5/12.3
10,800/10,600
305X1,550X68052
2.4(Charged for 15 m)
1,170X900X32087
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
421,482
46/37
3.75
57
42
FDMG42NUV1
R42NUY1
49,100/48,00014.4/14.1
12,400/12,100
305X1,550X68052
2.6(Charged for 15 m)
1,345X900X32092
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
421,482
46/37
4.50
59
48
FDMG48NUV1
R48NUY1
52,200/51,00015.3/15.0
13,200/12,900
305X1,900X68058
2.7 (Charged for 15 m)
1,345X900X32093
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
421,482
47/37
4.50
59
51
FDMG51NUV1
R51NUY1
50 (equivalent length 70 m)30
57,000/56,00016.7/16.4
14,400/14,1004.16/4.16 4.84/4.84 5.55/5.55 5.90/5.90 6.45/6.45
305X1,900X68058
2.8 (Charged for 5 m)
1,345X880X370114
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
421,482
47/37
4.50
56
56
FDMG56NUV1
R56NUY1
26
FDMG26NUV1FDMG36PUV1FDMG30PUV1 FDMG42PUV1 FDMG48PUV1 FDMG51PUV1 FDMG56PUV1FDMG26PUV1
R26NUV1R26NUY1
2.52.3(Charged for 10 m)
770X900X32070 (V1), 69 (Y1)
o/ 9.5o/ 15.9
o/ 26.0 (Hole)
57 57
26,300/26,0007.7/7.6
6,630/6,5503.15/3.15
23811
42/38Rated external static pressure mmH2O 9.810.1 8.0 8.0 9.8 9.88.5
305X1,350X68043
12
13
DUCT CONNECTION LOW STATIC PRESSURE TYPE
Outdoor unit
KIS95-------Drain piping kit -------
Indoor unit
Note: 1Wiring for wired remote controller to be procured locally.
CEILING SUSPENDED TYPE
Replacement long-life filterL-type piping kit (for upward direction)Remote controller
Resin net
Wireless typeWired type1
Note: 1Wiring for wired remote controller to be procured locally.
Remote controllerWireless typeWired type1
FDBG18PU FDBG21PU FDBG26PU
FH21NU FH26NU FH30NU FH36NU FH42NU
KHFJ5F160
FH48NU
FHC18NU FHC21NU FHC26NU FHC30NU FHC36NU FHC42NU FHC48NU
KAF501DA160KAF501DA80 KAF501DA112KHFJ5F80
-------Central drain plug KKPJ5F180
BRC1NU61BRC7NU66
CEILING MOUNTED CASSETTE TYPE
ItemType
Decoration panel
Fresh air intake kit Without the T-joint pipe and fanWith the T-joint pipe,without fan
Direct installation type
Chamber type
Sealing member for air discharge outletPanel spacer
Note:1Required for installing high-efficiency filter or ultra long-life filter. 2Wiring for wired remote controller to be procured locally.3This optional accessory requires DTA102A52.4Installation box for adaptor PCB (KRP1B98) is necessary.
High-efficiency filter
High-efficiency filter chamber Replacement long-life filter
(Colorimetric method 65%)(Colorimetric method 90%)
Replacement high-efficiency filter
(Colorimetric method 65%)(Colorimetric method 90%)
Remote controller Wired type2
Wireless type
Ultra long-life filterReplacement ultra long-life filterBranch duct chamber
BYC125K-W1, BYC125K-W2
KDDF55D160
KDBH55D160W
KDD55DA160KDD55DA160KKDDJ55X160
KAF551K160KAFP55D160KAF55K160H
KAF556DA80KAF557DA80
KAF556DA160KAF557DA160
KDJ55K80 KDJ55K160BRC1C61
BRC7C613W
KDBP55H160WA
KAFP552B80 KAFP552B160KAFP553B80 KAFP553B160
R18NU R21NU R26NU R30NU R36NU R42NU R48NU R51NU R56NU
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
DCS302CA61DCS301BA61DST301BA61
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
BRC4C64
FDMG26PU FDMG30PU FDMG36PU FDMG42PU FDMG48PU FDMG51PU FDMG56PU
BRC1C61
Note: 1Wiring for wired remote controller to be procured locally.
Remote controllerWireless typeWired type1
BRC4C64BRC1C61
Adaptor for wiring4
Wiring adaptor for electrical appendices3
Interface adaptor for SkyAir seriesInstallation box for adaptor PCB
KRP1BA57KRP4AA53DTA102A52KRP1B98
ItemType
ItemType
KRC47-2ARemote controllerDigital remote controller
FDMG26NU FDMG30NU FDMG36NU FDMG42NU FDMG48NU FDMG51NU FDMG56NU
KRC47-1A
ItemType
ItemType
ItemType
DIMENSIONS (Unit: mm)
1234567
89101112131415161718
Air discharge grilleAir suction grilleAir filterGas pipe connectionLiquid pipe connection Drain pipe connecitonEarth terminal (inside the electric components box) (M4)Suspension bracketBackward piping and wiring connection opening lidUpward piping and wiring connection opening lidRight side pipe connection Left back drain pipe connection Left side drain pipe connection Right side drain pipe connection Hole of wall for taking out in piping back Upward drain pipe connection Upward gas pipe connection Upward liquid pipe connection
Notes:1
2
3
A B
1120 1160
1120 1160
FH21NUV1
FH26NUV1
1550 1590
1550 1590
1550 1590
FH36NUV1
FH42NUV1
FH48NUV1
CEILING SUSPENDED TYPE
14
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.The remote control code is the standard <about 3 m outside the machine> attached.(0.5 mm2 2 wicks O.D. 5.4)(It is attached to VRV.)
CEILING MOUNTED CASSETTE TYPE
Notes:1Location of unit's Name Plate For Main body: Switch Box Cover inside surface of suction grille. For decoration panel: Panel frame inside surface of suction grille.2When installing an optional accessory, refer to the installation drawings. For fresh air intake kit Inspection port is necessary. For high efficiency filter unit Inspection port is not necessary.3In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.
Liquid pipe connectionGas pipe connectionDrain pipe connectionPower supply connectionRemote control code and control wiring connectionAir discharge grilleAir suction grillePort for water supplyCorner decoration coverDrain hose
1
2
3
4
5
6
7
8
9
10
C
165
195
A
230
288
B
240
298
D
----
165
E
----
195
FHC18NUV1-26NUV1
FHC30NUV1-48NUV1
FHC18NUV1 / 21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1
FH21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1
1360 1400FH30NUV1
���
��
��
��
� ���
���
��������
��� ���������
����
���
���
���
���
���
���
���
��� �� ����
�
�
��
��
���
��
���
��
�
���
�
���
�
��
���
�
�
�
�����
� �������
�
����� ��������������
�� !� "���#$��$���� ����%
����� ��������������
� �������
#$��$���� ����%� !� "���
#������ ������������ �&$�%
'�� (���� ��� ����)� )������������
����** �� *���
+��� ��� �������,� ,���� �� ��������-��� ��.����� �$��� �����** �� *���/
����** �� *���
����**�� *���
����**�� *���
0�.����� �$���
0�.�����
�$���
����
1��$������2���
�����
3����/
��
1��$�����
�$������
�
�� 1��$������ $�������
����
��*
���
�
4
�
��
�
�
��
�
�
�
��5
����
2��#
�6��
�%
� ! !��
��6�� ������, �$����,
��6��
�����
�,
�$����
,
������
���
��
���
���
�
���
�
���
�� !� "���#$��$���� ����%
����� ��������������
� �������
0�.�����
�$���
����
��*
���
�
��
��
[FHC30NUV1-48NUV1]
[FHC18NUV1-26NUV1]
��� ����
���� �� ������
�� �� ����
���� �� ������
�� �� ����
��������
���� �� ���
��!"�
#���$ ���� ����
%�� �� �� ���� &�� �' �� �( � � � �� ���'
��� ��& � � ���)�� � � �� ������ �� *%"�
�� ��
""+
",+
�,�
��+
�,�
�",
��" +�
�-
�+ �-�
�."��"
��+
��+.�
"��
"-�
�.+
���
",+
��+
��+
+
����� �� ������ ��
���������
/�0( ��$������
����
��&����� $�"+��������
1����������� � $�
++
-��
+�++
��+ -�
-+
��+-�
-+
��+
��
+� -�
.�"
�� �++.�
��
��
��
�+
�� �, �-
��
+
�
�"
-
+,
�
-
�
�
%�� �� 2 ���� �& 3��� &�� �' �� �( � � � �� ���'
* �3 &��� �� &����
* �3 &��� �� &����
�4 �+++
��
���� �� ��� ���5
#
���� ��
��� ���
/�0( ��$������ /�0( ��$������
DIMENSIONS (Unit: mm)
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Note: 1Location of unit's Name Plate: Chamber cap
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
15
FDMG26PUV1
1550
A B C E F G
1353 1403 1314 7XP150=1050 18-M4HolesFDMG30NUV1/36NUV1/42NUV1/48NUV1
FDMG51NUV1/56NUV1 1900 1703 1753 1664
D
1334
1684 9XP150=1350 22-M4Holes
1550
H J K M N O
1353 1337 7XP150=1050 20-M4Holes
1900 1703 1687
L
1321
1671 9XP150=1350 24-M4Holes
263
269
FDMG30PUV1 / 36PUV1 / 42PUV1 / 48PUV1 / 51PUV1 / 56PUV1
���
��
���
���
����
�
���
���
��� � �� �
�
�
��
���� � �����
�
���
�
���
��
�
������������������� �
!
" �
�
���
�
����������� ���� ���� �
��
#
$
���� � �����
%
���
��
�
���
���
&
��
���
���
��
'
(
�)
���
���
*
��
���
+
�
��
�
�� ,��� ��-��
Note: 1Location of unit's Name Plate: Chamber cap
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
�
��
����
���
�
���
��
��
��
�
�
���� ����
���
����
���
�
���
��
��
��� �������
�
����
�����
���
��
����
�
��
���
����
�
�
��
���
�
���� �������
������������������� �
�!"��#��
���
���
���
�
����
��
����������� ���� ���� �
���
���
����
���� �������
�!"��#��
�$
���
�
� �� %���
���&��� �����
16
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Note: 1Location of unit's Name Plate: Chamber cap
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
FDMG26NUV1
1550
A B C E F G
1353 1403 1314 7XP150=1050 18-M4HolesFDMG30NUV1/36NUV1/42NUV1/48NUV1
FDMG51NUV1/56NUV1 1900 1703 1753 1664
D
1334
1684 9XP150=1350 22-M4Holes
1550
H J K M N
1353 1337 7XP150=1050 20-M4Holes
1900 1703 1687
L
1321
1671 9XP150=1350 24-M4Holes
FDMG30NUV1 / 36NUV1 / 42NUV1 / 48NUV1 / 51NUV1 / 56NUV1
����
�
����
��
����
���
���������
���
�
���
�
���
��
�������������
���
�
���
���
�
�
���
����
�
����
�
���
����
����
��
���
���
����
���
���
��
���
���
���
��
���
����� �����
��
���
��
����
���
��
���
����������� ���� ����� ��
��������
�����
���
��
�!�� "#���$
�!�� "#���$
����� �����
��� �# %�#�
��#&��� ��"��
���������� �� ������
������������ ������
��� � ���
������� �����
��
�
��
�
���
��
���
�
�
��
�
�
!
�
���
"
��
��
#
���
���
���
���
$
���
�
���
� %
���
���
&
���
���
���
���
��
'
���
���
(
���
���
���
)
�'�� '���*�
���
���
�
+
,
�'�� '���*�
Note: 1Location of unit's Name Plate: Chamber cap
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
(Unit: mm)DIMENSIONS (Unit: mm)DIMENSIONS
17
DUCT CONNECTION LOW STATIC PRESSURE TYPE
Liquid pipe connection Gas pipe connectionDrain pipe connectionGround terminal
1234 Note: 1Location of unit's Name Plate: Chamber cap
Switch boxControl wiring intake (for remote controller)Control wiring intake (for outdoor unit)Suspension bracket
5678
A B C F G I
900
FDBG21PUV1/26PUV1 1300
704
1104
755
1155
D
684
1084
E
664
1064
3XP150=450 500 3XP150=450 674 688 704 900 10-M4Holes
12-M4Holes
6XP150=900 700
H
127
102 6XP150=900 1074 1088 1104 1300 16-M4Holes
18-M4Holes
FDBG18PUV1
J K L M N O
FDBG18PUV1 / 21PUV1 / 26PUV1
��������
� �� ���
���� �������
��
���
�
��
���
��
��
���
��
�
���
���� ��������
��
���
��
���
��
�
��
�
��
���
���
�
�
�
�
���
����� ����� ���� ���� �
����� ������������� �
�
�
���
�
�
���
��
��
���
���
���
!
"#
$
%
&
'
�
(
)
*
+
,
- .
� �/�� ����
OUTDOOR UNIT
R18NUV1
R21NUV1
18
����� ��� ���� ������� �� ����
����� �������
������� ���������� ���� ��� �� �����
�������
�����������!�
"�#�� ��$�
%� ���� ����
&�'��( ���� ����
)�*
���
�+�
+�
,
�
)-�
��.
)��
!�
-+
*��
*+� )*�
+!�
��+ +�
+)�
�-�
�*� )*
.�
+�� ��� �!
*)
�! )*
+�
+�
,
�+
&��� �� ����
���� �� ����
���� ,
���� �� ���
���� �� .��
�
/����� �����
� ����
� ����
������ �� � ��� ��� �����
���
���
���
�� ���
��
��
���
���
�
���
�
����� �����
�� ����
����� � ����
��
��
�
���
���
�
�����
�!�" ����
�!�"��� �����
#��� �����
$�%�� ����&�
'���( ��������)��*
+�"������ �(�������
���
���
���
���
,��
��
��
,-.���� �����
���� ��� �� (�� /���
)�� �� ���*
DIMENSIONS (Unit: mm)
19
OUTDOOR UNIT
R36NUV1/Y1
Gas pipe connection Liquid pipe connection Service port(in the unit) Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection
12345678
R26NUV1/Y1R30NUV1/Y1
Note: In some circumstances, with certain machine types, it may not be possible to attach the supplied piping.
Gas pipe connectionLiquid pipe connectionGrounding terminal M5(in switch box)
Refrigerant piping intakePower supply wiring intakeControl wiring intakeDrain connection
1
2
3
4
5
6
7
���
��
��
���
��
��
�
��
��
��
��
��
����
��
���
����
���
���
� ��
��
��
���
��
��
��������
��
��
��
�
��
�� � � ��
� �
��
��
�� �
��
�
��
��
��� ��
�
�
�
�
�
�
���� ��� ������
���� ����
���
��
���
��
��
��
�������
��
��� ���
��
��
���
�
�
�
�
�
�
�
�
�
�
�� �
��
��
��
��
��
�� ��
��� ���
���
�� ��
���
�� ��
��
���
�
��
�� �
� � ���
��
�� ��
��
�� ��
���
���� ��� ������
���� �����
�
�
���
�
���
��
��
��
20
OUTDOOR UNIT
R42NUY1, R48NUY1, R51NUY1
Gas pipe connectionLiquid pipe connectionService port (in the unit)
Grounding terminal M5 (in switch box)
Refrigerant piping intakePower supply wiring intakeControl wiring intakeDrain pipe connection
1
2
3
4
5
6
7
8
A
R42NUY1
R48NUY1/51NUY1
1170
1345
B
54
55
C
113
—
D
579
—
Gas pipe connectionLiquid pipe connectionService port(in the unit)
Grounding terminal M5(in switch box)
Refrigerant piping intakePower supply wiring intakeControl wiring intakeDrain outlet
1
2
3
4
5
6
7
8
R56NUY1
��
��
��
�
��
��
��
��
��������
�
�
��
���
��
�
��
��
�
�
��
�
��
��
�
��
��
��
��
�
�
�
�
��
��
��
���
�
�
�
� �
���
��
��
���
��
����
�
���
�
��
���� ��� ������
���� �����
�
�
��
�
��
��
���
��
�
�
�
�
�
�
�
�
�
�
�
�
�
�� �� �����
��� �����
���
����
��
�� ���
��
��
��
���
��
��
���
��
��
��
����
���
���
��
��
��
���
��
���
���
���
��
��
��
���� �����
��
���
�����
�� �� �� ��
���
���
21
REMOTE CONTROLLER
DIMENSIONS (Unit: mm)
����� ���
���� �
�
���
�
�
�� ��� ��
� ������ �����
������ ����
������ �����
�!������ ����
� "����#�� ���$��#��!��� ��#��������#� ��#���� ��� �
% ������ �����
�!������ ����
�#�&��
'()*'+ %'�
),��&-, ,���
�.�
���/������#� �/ ����
�0��� 0�� !!�
)���� ��#-�, ��� !
)��1�#�� ���� $��, �,���, �� �����
�2#�&����� �,��3#���4 !! �� !����
(���� 0 *�!��� ��#������� ���� �#�
����� ��� #�� �����,��0 �,�� ���
/���� �&���� ����0
(����
),� ��!�#���# �/ ,���0
5 �&#����� ��6&���#- �7 4 ,���� $���
��#�&����� �,��3#���4 !! �� !����
��
��
� 8
9�
89
:8
����&����,���
�8�:
9�
�������� ���
��������� �����
�������
��������
��������
)��#�!����#- ���
��
�� �0�
+�6&�� �������
��!��� ��#�������
����������
*�!��� ��#�������
,�����
� ����� ����� � ���� �� ���
� ����� ���� �� � ���
�
��
:8
�
�
9
:
���
*�
�
%
990�
�
��
%
�
��
��
�
9 0�
�
�
%
;
�9
�<��� ���
�
�
��
9
%
� �!!�
*����=��),� >��#�
�������
�������
�� 8
9
:�
�
;
�8
;�
�9
8�
:�
�
8
:�
*�!��� ��#������� ,�����
�#���������# �����&��
?2#���������# �� $��� �&�/���@
*�!��� ��#������� ,�����
�#���������# �����&��
?2#���������# �� $��� �&�/���@
)��#�!����#- ���
�0�
�9 80
*�!��� ��#�������
����������
*�!��� ��#�������
,�����
*����=�� �#���������# �����&��
��=��� ���� /�� �����#-
�#���������#
*����=�� ������
(��� 4
7����,�#;�
���=��������
��
��
8:0�
��
� ����#-��#�#-�
�� 8�0�:� 9;
� ����#- ��#�#-�
�A��; ���
$���, ���
�/���� &���� �����
"� #�� �#����� !��� �,�# :
�����=��� �# �,� =���#��� �/ �#�
�#��,��0
���, 9 �� !��� &#���� �,��� ��
��$��� �,� ���������� �/
!��/&#����#
*�!��� ��#������� ��!�#���#�
*�!��� ��#������� �#���������# �����&��
*����=�� ������
*�!��� ��#������� ��!�#���#�
*����=�� �#���������# �����&��
*����=��
"��������# �#��
"���# ��#-����
*�/��-���#���#- ����
*����=�� ������
22
H
L
500 or more
<1000>
50(100)
or more
1000 or more
<1500>
200(300)
or more
L H
L H
L H
[Space required for outdoor unit installation] (Unit: mm)Dimensions inside brackets [ ] indicate case where air direction adjustment guide is adjusted downward.
For R26NU-56NU
200(300) or more
1000 or more
200 or more
100 or more
100 or more100 or more
50(100) or more
1000 or more
100 or more
500 or less
1000
or m
ore
500 or more
150 or more
150 or more 150 or more
500 or less
1000
or m
ore
200(300) or more
1000 or more
200 or more
500 or less
1000
or m
ore
500 or less
500 or more
1000
or m
ore
500 or less
1000 or more
1000
or m
ore
When there is an obstruction on the inlet side
When the obstruction on the outlet side is higher than the unit itself (There is no limit to the height of the obstruction on the outlet side.)
When there are obstructions on both the inlet and outlet sides
When there is an obstruction on the outlet side
When there are obstructions on the inlet side and both lateral sides
2. For series installation (more than two units)
When there are obstructions on both sides
Pattern 1
When the overhead space is open
1. For single unit installation
When there is an obstruction only on the inlet side
When there is an obstruction in the overhead space
When the overhead space is open
When there are obstructions on both sides
When there is an obstruction in the overhead space
When there is an obstruction on the inlet side
When there are obstructions on the inlet side and both lateral sides
2. For series installation (more than two units)
1. For single unit installation
1. For single unit installation
When the overhead space is open
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
1. For single unit installation
2. For series installation (more than two units)
An obstruction in the overhead space
An obstruction in the overhead space
An obstruction in the overhead space
An obstruction in the overhead space
For other patterns, please referto engineering databook.
An obstruction in the overhead space
The values represent the case for the R26 type through R56 type. The dimensions in ( ) are for the R36 and R56 type (The unit values is mm. )In case of R56 model, the values in < > are those when the air discharge direction of the grille is downward.
DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of April 2011 but subject to change without notice.
JMI-0107 JQA-1452
Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES.
Organization:DAIKIN INDUSTRIES(THAILAND) LTD.
Scope of Registration:THE DESIGN/DEVELOPMENTAND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM
All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.
All rights reserved 04/11/002 YW• SSc