1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea, direct exposure to sea breeze should be avoided. If you need to install the outdoor unit close to the sea, contact your local distributor.
Cautions on product corrosion
Specifications, designs and other content appearing in this brochure are current as of August 2012 but subject to change without notice.
Daikin AustraliaPty Limited (ISO9001)
QEC23256 May 31, 2006Sydney, Brisbane, Adelaide,
Melbourne, Newcastle, Townsville, Perth, Auckland
Daikin AustraliaPty Limited (ISO14001)
CEM20437 October 27, 2006Sydney, Brisbane, Melbourne,
Adelaide
Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES.
Organization:DAIKIN INDUSTRIES (THAILAND) LTD.
Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM
All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion and may have resultant impacts on warranty.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
JQA-1452JMI-0107
PCRAU0726F
Multi-Split Type Air Conditioners L Serieswith DC Inverter Power ControlCooling Only & Heat Pump [50 Hz]
Connectable to max. 9 indoor units
1 2
• Connectable to max. 9* indoor units
Daikin’s Super Multi PLUS L series is connectable to up to 9 indoor units and offers you a richer choice of indoor units to coordinate with each room décor. Advanced technology from Daikin has achieved a high COP and low sound level to suit today’s modern living environment.
An 11.2 to 15.5 kW Multi-Split system that suits large and luxurious houses
Main features of Daikin’s SUPER MULTI PLUS
3 models of outdoor units are available in the wide range of 11.2, 14 and 15.5 kW classes. A maximum of 9* indoor units can be connected.
Wide range of outdoor units
32 models of indoor units grouped into 7 types (heat pump)—ceiling-mounted cassette, ceiling-mounted built-in, ceiling-suspended, duct-connected, wall-mounted, floor-standing, and floor/ceiling-suspended dual types—provide a wide range of options for interior coordination.
Wide variety of indoor units
The scroll compressor, DC inverter and DC fan motor technologies are energy efficient, achieving high COP values.
Energy efficient
Great flexibility in installation
Quiet operation
* Combination is possible with 15.5 kW class outdoor unit and 2.0 kW class indoor units.
* Combination is possible with 15.5 kW class outdoor unit and 2.0 kW class indoor units.
Long piping lengths of 145 m for the 15.5 kW class outdoor unit and simplified wiring reduce restrictions on the installation position.
Latest technologies and features achieve the quiet sound level of 43 dB (A) during night quiet mode operation for outdoor units, realising comfortable operation.
NewNew
3 4
Wide range of choicesWide range of choices A wide variety of stylish indoor units
A wide range of indoor and outdoor units
The outdoor unit can be selected from three models for the precise power to suit the size of house, shop or office.
3 models11.2 kW, 14 kW, 15.5 kW
Outdoor unit
To suit every room in large houses, small shops and small offices, the Super Multi PLUS L series offers a wide range of indoor and outdoor units.
32 models 7 types (heat pump)Indoor unit
RMK(X)S112LV1A (11.2 kW)
RMK(X)S140LV1A (14 kW)
RMK(X)S160LV1A (15.5 kW)
Ceiling-mounted cassette type Ceiling-mounted built-in type
Duct-connected typeCeiling-suspended type
Floor/ceiling-suspended dual type
Wall-mounted type Floor-standing type
600 x 600
NewNew
Type
Ceiling-mounted cassette type
Wall-mounted type
Floor-standing type
Floor/ceiling-suspended dual type
Ceiling-mounted built-in type
Duct-connected type
Ceiling-suspended type
Model name 202.0
252.5
353.5
505.0
606.0
717.1
202.0
252.5
353.5
505.0
606.0
717.1Rated capacity (kW)
Cooling only Heat pump
FCQ-B
FFQ-B
FBQ-B
FHQ-B
CDKS-EA(700 mm
width type)
FTXS-K
FTXS-KA
Model nameRated capacity (kW)
FCQ-B
FFQ-B
FBQ-B
FHQ-B
CDXS-EA(700 mm
width type)
FVXS-K
FLXS-B
A wide range of indoor units includes 32 heat pump models in 7 types and 25 cooling only models in 5 types. Indoor units can be selected to match each room and preference.
CDKS-C(900/1,100 mm
width type)
FDXS-C(900/1,100 mm
width type)
FLXS-G
FTKS-KA
FTKS-K
5 6
The Super Multi PLUS L series outdoor units use the latest technologies for energy efficient performance and quiet operation.
Energy efficiency and quiet operationEnergy efficiency and quiet operation
RMXS160L
Master bedroom 3.5 kW class
Bedroom (1) 2.0 kW class
Bedroom (2) 2.5 kW class
Cooling operation Heating operation
Power consumption 1,990 W
COP 3.93
What is COP? An air conditioner's COP (coefficient of performance) indicates how efficiently it uses energy. A high COP means high energy efficiency.
COP = Capacity (W)
Power consumption (W)
Power consumption 2,210 W
COP 4.21
Energy Efficient
During night time
With DC inverter power control the air conditioner can operate at low capacity most of the time. DC inverter power control is able to achieve a high COP even when multiple indoor units operate simultaneously for long periods of time.
Quiet operation
Quietness is yet another important feature of Daikin’s Super Multi PLUS L series. To reduce sound, latest technologies and features are applied to the outdoor units, achieving quiet operating sound level of 43 dB (A) in night quiet mode.
Night quiet mode
Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours*1 after the peak temperature in the daytime, and operation will return to normal 10 hours*2 after that. The operation sound level for the night mode can be selected from 49 dB (A) (Step 1), 46 dB (A) (Step 2) and 43 dB (A) (Step 3).
Automatic modeMode 1. Automatic mode (For RMKS112L)Mode 1.
Starting time and ending time can be input. (External control adaptor for outdoor unit, DTA104A61 or DTA104A62, and a subsequently obtained timer are necessary.)
Manual modeMode 2.
Combination of mode 1 and 2 can be used depending on your needs.
Combined modeMode 3.
*1. Initial setting. Can be selected from 6, 8 and 10 hours.*2. Initial setting. Can be selected from 8, 9 and 10 hours.
Notes: • This function is available in setting at site.
• The relationship of outdoor temperature (load) and time shown in the graph is just an example.
Peak in the outdoor temperature
Capa
city
%
8 hrs 10 hrs
Oper
atio
n so
und
dB (A
)
49
8:00 12:00 16:00 20:00 0:00 4:00 8:00
50
100
520
Load
%
Night mode endsNight mode starts Night mode endsNight mode starts
Night Mode
46
43
(Initial setting)(Initial setting)
Step 1 max. - 3dB (A)(11.2 kW)
Step 2 max. - 6dB (A)(11.2 kW)
Step 3 max. - 9dB (A)(11.2 kW)
Step 1: 49 dB (A)
Step 2: 46 dB (A)
Step 3: 43 dB (A)
Operation sound level selectablefrom 3 steps for the night mode
The capacity reduction rate differs depending on the operation sound level step selected.
These two features work to reduce sound. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence.
Smooth Air Inlet Bell Mouth and Aero Spiral Fan
Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence.
Efficient and quiet operation
The high efficiency compressor to achieve a higher COP
2
1
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.
DC fan motorEfficiency improved in all areas compared to conventional AC motors, especially at low speeds.
Sine wave DC inverter >> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency.
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
*2. The torque created by the change in power between the iron and magnet parts.
Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor.
Compressor equipped with Reluctance DC motor
3DC motor efficiency
(Comparison with a conventional AC motor)
200 300 400 500 600 700 800 900 1000
0
20
40
80
60
100
Eff
icie
ncy
(%
)
Motor speed (rpm)
AC motorAC motorAC motorAC motorAC motorApprox.
40%increase
Approx.
20%increase
DC motorDC motorDC motorDC motorDC motorDC fan motor structure
RMK(X)S112LRMK(X)S140LRMK(X)S160L
ReluctanceDC motor
3
1
2
With the bent blade edge
Without the bent blade edge
500 30 60 90 120
60
70
80
90
Rotational speed (rps)
AC motor
Conventional DC motor
Reluctance DC motor
Mo
tor
effi
cien
cy (
%)
Small load Large loadLow capacity High capacity
More than 20%
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.
Masterbedroom
Bedroom (1)
Bedroom (2)
7 8
The BP unit is an innovative development which allows Super Multi PLUS outdoor units to be connected to a wide range of different indoor unit types. The BP unit has the ability to precisely vary refrigerant volume to meet the cooling requirements of individual room spaces.
Optional REFNET joint: KHRP26A22T
3 ports BPMKS967A3
2 ports BPMKS967A2
The REFNET joint reduces the amount of work involved in installation and increases the reliability of the system.
Total main piping length
Total branch piping length
Total main and branch piping length
55 m90 m
145 m (55 + 90)
The outdoor unit and the BP units operate from separate single-phase power supplies, so no power supply wiring is needed between them. The size of the wiring pipe from the outdoor unit to the BP units can be reduced, making installation easier.
BP unit REFNET joint
Simplified electrical wiring connection
The outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion. A hydrophilic film layer also prevents rust caused by the run off of water droplets.
Durable outdoor unitA single high-capacity outdoor unit can drive up to 9 indoor units, making it powerful enough to air-condition a whole residence. This powerful unit can be easily installed on a balcony with its slimline design, which measures (H) 1,345 x (W) 900 x (D) 320 mm.
Space saving
The Super Multi PLUS has the wide operation range required for commercial-use air-conditioning systems.
Wide Operation Range
A maximum total piping length of 145 m offers flexibility in the choice of installation positions for the indoor units, and simplifies system planning.
The Super Multi PLUS L Series is connectable to up to 9 indoor units. While the BP unit and the REFNET joint make installation simple, long piping length and simplified wiring broaden design flexibility.
Design flexibility and easy installationDesign flexibility and easy installation
Thin refrigerant piping makes handling and connecting easier, resulting in significantly reduced installation time.
As many as 9 indoor units can be connected to a single outdoor unit
Long refrigerant piping
Piping length for RMK(X)S160L
Note: Refrigerant charge is required. (Chargeless piping length 0 m)
>> 8 indoor units for a 14 kW installation >> 6 indoor units for a 11.2 kW installation
30 mMax. height difference
Main piping
BP unit
BP unit
Branch piping
Branch piping
For outdoor unit 15.5 kW installation
BP unit(2 ports)
Outdoor unit
Safety breaker
Powersupply
Powersupply
BP unit(2 ports)
BP unit(3 ports)
30 A
15 A
Transmission line (4 lines)
(Indoor unit--BP / including earth wire)
Earth wire
Earth wire
Earth leakage circuit breaker
Safety breaker
Earth leakage circuit breaker
D transmission line (2 lines)
(Outdoor unit--BP, BP--BP)
units9
1 2 3
4 5 6
7 8
Heat exchanger fin
Hydrophilic film
Aluminium
Corrosion-resistantacrylic resin
Cross section of anticorrosion-treated fin
900 mm 320 mm
1,345 mm
-10
0
10
20
30
40
50
-20
-10
0
10
20 15.5°C WB
Heating
46°C DB
Cooling
-5°C DB–15°C WBO
utdo
or te
mpe
ratu
re (°
C D
B)
Out
door
tem
pera
ture
(°C
WB
)
9 10
Central remote controllerDCS302CA61
Unified on/off controllerDCS301BA61
Schedule timerDST301BA61
5-room centralised controllerKRC72
• Max. 64 groups controllable• Zone control• Malfunction code display
64 groups (zones) of indoor units can be controlled individually same as LCD remote controller.
• Max. 16 groups controllable• Operating status indication• Centralised control indication
16 groups of indoor units can be operated simultaneously/individually.
• Max. 128 indoor units controllable• The start and stop time for twice a day can be set for the week in a unit of one minute.
128 indoor units can be operated on a 7-day programmed schedule.
• Max. 5 indoor units controllable• Contribute to save energy by eliminating turn-off of lamps.
5 indoor units can be controlled. This is a low cost system which can only control about on/off.
Central remote controller (option)
Unified on/off controller (option)
Schedule timer (option)
5-room centralised controller (option)
Centralised Control systemCentralised Control system Indoor unit lineupIndoor unit lineupBoth Super Multi PLUS and VRV systems are compatible with the Building Air-Conditioning Control System. This allows Super Multi PLUS and VRV units to be conveniently operated from the same common controller when the two systems are installed together in a building.
Compatible indoor units
FCQ, FFQ C(F)DK(X)SFBQ FTK(X)SFHQ FVXS FLXS
Type
Ceiling-mounted cassette type
Wall-mounted type
Floor-standing type
Floor/ceiling-suspended dual type
Ceiling-mounted built-in type
Duct-connected type
Ceiling-suspended type
Model name 20
2.0
25
2.5
35
3.5
50
5.0
60
6.0
71
7.1
20
2.0
25
2.5
35
3.5
50
5.0
60
6.0
71
7.1Rated capacity (kW)
Model name
Rated capacity (kW)
Cooling only Heat pump
FCQ-B
FFQ-B
FBQ-B
FHQ-B
CDKS-C(900/1,100 mm
width type)
FCQ-B
FFQ-B
FBQ-B
FHQ-B
FDXS-C(900/1,100 mm
width type)
FTXS-K
FTXS-KA
FVXS-K
FLXS-B
CDKS-EA(700 mm
width type)
CDXS-EA(700 mm
width type)
FLXS-G
600 x 600
Central remote controller*1
Unified on/off controller*1
Schedule timer*1
5-room centralised controller*2
Notes: *1. An interface adaptor (KRP928BB2S or DTA112BA51) is also required for each indoor unit.*2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
FTKS-K
FTKS-KA
11 12
Ceiling-mounted cassette (multi flow) typeCeiling-mounted cassette (multi flow) type
3.5 kW class
FCQ35BVE
FCQ35BVE
5.0 kW class
FCQ50BVE
FCQ50BVE
6.0 kW class
FCQ60BVE
FCQ60BVE
7.1 kW class
FCQ71BVE
FCQ71BVE
The ideal air conditioner for installation inside narrow false ceilings—with only the decoration panel visible after installation. A simple design makes it comfortable to the public eye in shops and small offices in tenant buildings, as well as right at home in the living rooms with false ceilings found in multi-storey apartment blocks.
Specially designed for false ceilings—for a smooth, modern interior finish Comfort and quietness
Standard: a swing range of 10 to 65 Draft prevention: a limited swing range of 10 to 40 prevents airflow from blowing directly onto people.Soiling prevention: a limited swing range of 30 to 65 prevents ceilings from becoming dirty due to direct airflow.
Three convenient patterns for auto-swing operation
The turbofan was designed using aviation technology to reduce draft resistance inside the unit, achieving quiet sound level of 33/29 dB (A) to 35/30 dB (A).
Quiet operation
Allows fresh air to be circulated using only the fan for improved room ventilation. This is useful in buildings where ventilation fans cannot be installed.
Optional fresh air intake kitA chamber can be connected to the air conditioner to provide additional airflow for crowded spaces or areas sensitive to outside temperatures.
Optional branch duct chamber
Design flexibility
All models feature a decoration panel with the same compact size and simple design for easier planning of lighting systems and harmonising of interior décor.
Compact decoration panel
Installation flexibility
These models have the power to provide a comfortable airflow even with a ceiling height of up to 3.8 m.
High-ceiling applications
The indoor units weigh only 24 kg and require an installation space with a height of just 245 mm.
Light and compact main units
A system provides lift for the drain pump of up to 750 mm from the ceiling. This is convenient for multi-storied buildings, which have a large amount of other piping and wiring inside the ceiling.
High-lift drain pump
Standard
Draft prevention
Soiling prevention
950 mm
950
mm
Min. 245 mm
Same for all models
750 mm
Max. 3.8 m
Intake ductFresh air intake kit (Outdoor)
Hood
Air filterDischarge duct
Branch duct chamber
Discharge panel
Note: The intake duct, hood, air filter, insect screen, fireproof damper, etc. should be obtained locally if required.
Note: The discharge duct, discharge panel, etc. should be obtained locally if required.
Decoration panel is optional
Diffuser
3-dimensional blade
Option
Signal receiver unitNote: Wireless remote controllers and signal receiver units are sold as a set.
OptionNote: Remote controller cables not included. Cables should beobtained locally.
FCQ35
33/29 dB(A)
FCQ50
33/29 dB(A)
FCQ60
35/30 dB(A)
FCQ71
35/30 dB(A)
(H/L)
Coolingonly
Heatpump
13 14
Ceiling-mounted cassette (compact multi flow) typeCeiling-mounted cassette (compact multi flow) type
Coolingonly
Heatpump
2.5 kW class
FFQ25BV1B
FFQ25BV1B
3.5 kW class
FFQ35BV1B
FFQ35BV1B
5.0 kW class
FFQ50BV1B
FFQ50BV1B
6.0 kW class
FFQ60BV1B
FFQ60BV1B
The ideal air conditioner for installation inside narrow false ceilings—with only the smooth and simply finished decoration panel visible after installation. The compact dimensions are suitable even for the light commercial market as well as for the living rooms with false ceilings found in multi-storey apartment blocks.
Compact dimensions suitable for the light commercial market Design flexibility
Designed to fit 600 mm wide ceiling grids Quiet sound level of only 24.5 dB (A)
Multi-flow system offers a selection of air discharge patterns that suit all areas.
Comfort and quietness
600 x 600
Option
Option
Signal receiver unitNote: Remote controller cables not included. Cables should beobtained locally.
Note: Wireless remote controllers and signal receiver units are sold as a set.
Even for modules other than 600 x 600, no inspection opening is required. Maintenance can be performed after simply removing the grille, because the switchbox is built into the unit.
T-bar grid does not need to be cut.
575 mm
575 mm
700 mm
700 mm
286 mm
Compact
decoration panel
T-bar
600 mm600 mm
Ceiling panel
Spiral hub cover
At low fan speeds, the 2.5 kW model produces sound of only 24.5 dB (A), and even the 6.0 kW model as low as 32 dB (A). This is due to a spiral hub cover that reduces internal airflow resistance.
4-way flow
1 pattern
3-way flow
4 patterns
2-way flow
1 pattern
" " denotes piping direction. " " denotes sealing member for air discharge outlet (option).
Note: For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close off the unused outlet(s).
Low draft performance is designed for your comfort.
Horizontal Flow0° 0°
Less draught
FFQ25
29.5/24.5 dB(A)
FFQ35
32/25 dB(A)
FFQ50
36/27 dB(A)
FFQ60
41/32 dB(A)
(H/L)
Settable to 5 different levels between 0° and 35°
Settable to 5 different levels between 0° and 60°
Settable to 5 different levels between 25° and 60°
Auto-swing between 0° and 35°
Auto-swing between 0° and 60°
Auto-swing between 25° and 60°
Draft prevention setting(Set on site)
(Set on site)
Standard setting
Setting to prevent soiling of ceiling
Conditioned air is distributed evenly by Auto-swing operation.
Adjustable airflow angle to suit all room conditions.
AUTO-SWING
0° 0°
0°
25°
60° 60°
0°
35°
25°
60°
35°
60°
5 direction
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
Comfortable across all areas
15 16
Ceiling-mounted built-in typeCeiling-mounted built-in type
Coolingonly
Heatpump
6.0 kW class
FBQ60BV1
FBQ60BV1
7.1 kW class
FBQ71BV1
FBQ71BV1
This ceiling-mounted built-in air conditioner is highly flexible in installation. The visible part is small, with a simple finish that blends in with any type of room.
Flexible air discharge unit to fit various forms of space Installation flexibility
The indoor unit can be installed in rooms with as little as 350 mm between the drop ceiling and ceiling slab. It also works with both flexible and ordinary ducts.
Meets diverse installation needs
Drainage pipes can be run as high as 250 mm above the drain outlet.
Provided with drain water lift-up mechanism as standard equipment Available in two types: 65% and 90%
colourimetry.
High-efficiency filter (option)To cope with the challenges of L-shaped or U-shaped spaces, it is possible to install the air discharge unit away from the main unit. This extends the possibilities for coping with human gathering patterns or sun lighting. At the same time, different types of architectural space can be kept comfortable.
Flexibly adapts to room interiors
Comfort and quietness
Quiet operation
Note: Remote controller cables not included. Cables should beobtained locally.
L-shaped room U-shaped room Long room
250 mm
Comfort and quietnessFBQ60
41/35 dB(A)
FBQ71
41/35 dB(A)
(H/L)
Option
Canvas bellows and air intake panel
Flexible duct(dia. 200 mm)
Flexible duct(dia. 150 mm)
Branch duct
Air discharge grille
Air discharge chamber
Air discharge opening adaptor
Decoration panel
1
3
7
1
1
1
2
3
3
4
8
9
7911
5
10
46
5
Air conditioner
Long-life filter
Air blow Air intake
425 mm or more46
5
2 2Air conditioner
Long-life filterAir blowAir intake
350 mm or more
Standard installation examples
With high-efficiency filter Ceiling return
In crawl space With canvas bellows and air intake panel (sold separately)
45 mm
46
5
Air conditioner
Long-life filter
Air blow
Air intake450 mm or more
8
Air conditioner Ordinary duct(procured locally)
Ordinary duct(procured locally)
Air blow Air intake
460 mm or more
8
Air intake
Ceiling return with high-efficiency filter With ordinary ducts
46
5
Air conditioner
Air blow Air intake
540 mm or more13
946
5
Air conditioner
Air blow
540 mm or more
Options
Air discharge opening adaptorDecoration panel
Canvas bellows and air intake panelFlexible ductAir discharge grille
Air discharge opening flangeRear intake blocking pad
6
7
8
Air discharge chamber
Inspection panelHigh-performance filter
11
12
13 Low-draft filter chamberBranch ductRear intake filter chamber1011
22
2
17 18
Ceiling-suspended typeCeiling-suspended type
This ceiling-suspended type air conditioner features a slim body with a quiet and wide airflow.
Slim body with quiet and wide airflow Comfort and quietness
Auto-swing for comfort in all directions.
Spreads comfortable air throughout the room
Easier to maintain
Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).
Long-life filter lasts approximately 1 year*
Quiet operation has been emphasised even more on the exposed ceiling suspended type unit.
Quiet operation
Design and installation flexibility
Uniform height and depth. Narrower design for small-capacity models to meet tighter dimensional constraints.
Easier installation for greater freedom of design
Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening.
Drain pump kit (option) can be easily incorporated
FHQ35
37/32 dB(A)
FHQ50
38/33 dB(A)
FHQ60
39/33 dB(A)
(H/L)
Wide air discharge openings produce a spreading 100° airflow
Installable on ceilings 3.5 m high
Uses quiet stream fan and other quiet technologies.
100°
Sound damper
Turbulent flow is produced
Straightening vane
Quiet stream fan
195
960 1,160
680
(mm)
Height
Indoor unit
Width
Depth
FHQ35 FHQ50 FHQ60
Drain pump kit (built inside main unit)
600 mm
Non-dew flap
* For dust concentration of 0.15 mg/m3
Absence of bristles minimises clinging dirt and simplifies cleaning.
Non-dew flap without bristles
It is easy to wipe dirt off the flat side and lower surfaces of the unit.
Easy-clean, flat surfaces
Coolingonly
Heatpump
3.5 kW class
FHQ35BVV1B
FHQ35BVV1B
5.0 kW class
FHQ50BVV1B
FHQ50BVV1B
6.0 kW class
FHQ60BVV1B
FHQ60BVV1B
Option
Option
Signal receiver unitNote: Remote controller cables not included. Cables should beobtained locally.
Note: Wireless remote controllers and signal receiver units are sold as a set.
* Capacity may be affected.
* Capacity may be affected.
19 20
Duct-connected typeDuct-connected type
Coolingonly
Heatpump
2.5 kW class
CDKS25EAVMA
CDXS25EAVMA
3.5 kW class
CDKS35EAVMA
CDXS35EAVMA
Coolingonly
Heatpump
5.0 kW class
CDKS50CVMA
FDXS50CVMA
6.0 kW class
CDKS60CVMA
FDXS60CVMA
The visible parts have a smooth and sophisticated finish that blends with any type of interior décor. A wireless remote controller is a standard feature with prewired receiver, offering you great convenience.
Slim and smooth design suits your shallow ceiling
Notes: 1. To prevent an increase in operation noise, avoid installing the air suction grille directly below the suction chamber. 2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Duct-connected types do not have drain-up pumps. 3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.
Suction grille (KDGF19A45)
Option
Signals from the wireless remote controllerare transmitted to the signal receiver.
240 mm
Installation flexibility
Models in the CDKS-EA and CDXS-EA series are only 700 mm in width and 21 kg in weight, so are easily installed in limited spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and ceiling slab, making them ideal for even shallow ceilings.
CDKS25C(F)DXS25
35/31/29 dB(A)
CDKS50FDXS50
37/33/31 dB(A)
CDKS60FDXS60
38/34/32 dB(A)
(H/L/SL)
Slim and compact design
Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting.* Home Leave Operation can be selected for any temperature from 18 to 32˚C for cooling operation and 10 to 30˚C for heating operation.* Home Leave Operation function must be set using the remote controller when going to sleep or leaving the house, and after waking up or returning home.
Home Leave Operation
Comfort and quietness
Quiet operation sound level of only 29 dB (A) is achieved.
Quiet operation
Dimensions (H x W x D)WeightAirflow rate (H)External static pressure
200 x 700 x 620 mm21 kg
30 Pa
200 x 900 x 620 mm25 kg
40 Pa
CDKS25EACDXS25EA
CDKS35EACDXS35EA
CDKS25CFDXS25C
200 mmOnly 700 mm
CDKS-EACDXS-EA
900 mm 200 mm
* Width for the CDKS60C and FDXS60C models is 1,100 mm.
700 mm width type 900/1,100 mm width typeOption
* Locally obtained parts
AIRAir suction grille*
Suction duct*
Signal receiver
Air discharge duct*
Suspension bolt*
Air discharge grille*
Signal receiver wireLength = 1,900 mm
Chamber
AIR
Air filter
158 /s 167 /s145 /s
2.5 kW class
CDKS25CVMA
FDXS25CVMA
3.5 kW class
CDKS35CVMA
FDXS35CVMA
CDKS35C(F)DXS35
35/31/29 dB(A)
CDKS35CFDXS35C
CDKS-CFDXS-C
21 22
FTKS20/25
38/25/22 dB(A)
FTKS35
42/26/23 dB(A)
FTKS50
44/35/32 dB(A)
FTKS60
45/36/33 dB(A)
FTKS71
46/37/34 dB(A)
Titanium Apatite Photocatalytic Air-purifying Filter
Air filterCatches dust
Coolingonly
Heatpump
Coolingonly
Heatpump
Wall-mounted typeWall-mounted type
Stylish flat panel harmonises with your interior décor Versatile remote control
The simple and sophisticated flat panel design coordinates smoothly with any type of interior décor. Its refined design and functions provide you with a comfortable living environment, all year round.
The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built-in Weekly Timer that can be programmed to suit your lifestyle, with up to four actions per day for each day of the week.This controller not only allows you to programme on and off times, but also the desired temperature during those times. Furthermore, the ‘copy’ function enables any daily programme to be replicated on any other day or days as required.
Comfort and quietness
Wall-mounted type indoor units achieve quiet sound level of 22 dB (A).
Quiet operation
(H/L/SL)
Econo ModeEcono Mode reduces the maximum running current and the maximum power consumption of the outdoor unit to the rated values. This is useful when using multiple air conditioners and other electrical devices at the same time.
From start-up until set temperature is reached
Maximum
Rated
• This diagram is a representation for illustrative purposes only.• Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature.
Maximum during normal operation
Running current and power consumption
Time
Normal operation
Econo Mode
Maximum during Econo Mode
Clean air
Titanium Apatite Photocatalytic Air-Purifying Filter
Titanium apatite is a photocatalytic material with high adsorption power. Titanium apatite also effectively adsorbs and decomposes bacteria across its entire surface. The photocatalyst is activated simply by exposure to light.
These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal TestTesting method: dropping methodResult certificate: No. 012553-1 and 012553-2Testing organisation: Japan Spinners Inspecting Foundation
OptionIntelligent EyeIntelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2˚C for energy savings.
When you are in the room When you go out
Comfort Airflow ModeComfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body. With this function, when you press the COMFORT button during cooling operation, the flap moves upward to prevent direct cold drafts. During heating operation, it also moves downward to prevent direct drafts and deliver warm air to the floor.
Cooling operation Heating operation
A luminescent material is used for the buttons on the surface.
The LCD panel with backlight Weekly Timer
operation button
* Capacity may be affected.
2.5 kW class
FTKS25KVMA
FTXS25KVMA
2.0 kW class
FTKS20KVMA
FTXS20KVMA
3.5 kW class
FTKS35KVMA
FTXS35KVMA
5.0 kW class
FTKS50KAVMA
FTXS50KAVMA
6.0 kW class
FTKS60KAVMA
FTXS60KAVMA
7.1 kW class
FTKS71KAVMA
FTXS71KAVMAOption
23 24
Floor-standing typeFloor-standing type
Heatpump
3.5 kW class
FVXS35KV1A
2.5 kW class
FVXS25KV1A
5.0 kW class
FVXS50KV1A
A space-saving air-conditioner of simple and neat appearance. It distributes airflow to the furthest corners with efficient Vertical Auto-Swing and Wide-Angle Louvres.
Dual discharges to evenly distribute air across the whole roomDual air discharge for enhanced comfort
Clean air
Stylish and compact flat panel
Versatile remote control
Daikin’s inverter floor standing units are especially effective in heating. The unit features dual air outlets that diffuse warm air at floor level, and vertical auto swing louvers on the top air outlet, providing uniform distribution of heated air in the room. In warmer months, the lower air outlet can be shut off, leaving the top air diffuser to stream cool refreshing air upwards.
Double airflow keeps feet warm during heating operation.
Uses a Titanium Apatite Photocatalytic Air-Purifying Filter. Titanium apatite is a photocatalytic material with high adsorption power. It effectively adsorbs and removes bacteria.These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal TestTesting method: dropping methodResult certificate: No. 012553-1 and 012553-2Testing organisation: Japan Spinners Inspecting Foundation
Internal structure
3D air filter catches dust.Titanium apatite photocatalytic air-purifying filter
The clever construction of the elegant flat panel unit allows the flexibility of fully exposed installation against a wall or semi-recessed installation in spaces such as in a mantelpiece.
Easy to cleanThe flat panel design makes cleaning the front face of the unit a breeze. Surface dust can be simply wiped away with a soft cloth. Furthermore, the unit can be installed off the floor to allow for cleaning of the floor space under the unit.
The remote controller with a backlit liquid crystal display and luminescent control buttons also features a built-in Weekly Timer that can be programmed to suit your personal lifestyle, with up to four actions per day for each day of the week.This controller not only allows you to programme on and off times, but also the desired temperature during those times. Furthermore, the ‘copy’ function enables any daily programme to be replicated on any other day or days as required. Correct programming of the unit may also result in considerable energy savings.
Weekly Timeroperation button
Wiping clean the flat panel is a breeze. Easily clean beneath the unit.
* Capacity may be affected.
25 26
Floor/ceiling-suspended dual typeFloor/ceiling-suspended dual type
Heatpump
2.5 kW class
FLXS25BVMA
3.5 kW class
FLXS35GVMA
5.0 kW class
FLXS50GVMA
6.0 kW class
FLXS60GVMA
The floor/ceiling-suspended dual type’s slim, rounded design allows both ceiling-suspended and floor-level installation. Ceiling-suspended installation frees up wall and floor space, while floor-level installation is possible.
Floor/ceiling dual use maximises free space
Two-way installation
Comfort and quietness
Vertical Auto-Swing and Wide-Angle Louvres realise that comfortable airflow spreads throughout a large room. With these functions, the whole room can be evenly air-conditioned from either a floor-level or ceiling-suspended installation. The louvres can be adjusted by hand.
Comfortable airflowThe curved design of the indoor unit merges smoothly with the wall or floor to enhance the décor of any room.
Slim and attractive indoor unit
The indoor unit is only 490 mm in height and weighs a featherlight 16 kg, which means it can be quickly and efficiently installed by one person.
Compact and lightweight indoor unit
The floor/ceiling-suspended dual type indoor units achieve quiet sound level of 28 dB (A).
Quiet operation
FLXS25
37/31/28 dB(A)
FLXS35
38/32/29 dB(A)
FLXS50
47/39/36 dB(A)
FLXS60
48/41/39 dB(A)
(H/L/SL)
During cooling operation
The Vertical Auto-Swing and Wide-Angle Louvres direct warm/cool air to every corner of your room.
Clean air
Design and installation flexibility
The Photocatalytic Deodorising Filter is able to decompose odours and even removes bacteria and viruses. This filter can be used indefinitely if regular maintenance is carried out.Bacteria Removal TestTesting method: dropping methodResult certificate: No. 298081197-003Virus Removal TestTesting method: washout methodResult certificate: No. 298081197-004Testing organisation: Japan Food Research Laboratories
Photocatalytic Deodorising Filter
Ceiling-suspended installation Floor-level installation
1,050 mm200 mm
490
mm
27 28
Functions
Models Indoor unit Outdoor unit
FCQ FFQ FBQ FHQ CDK(X)S/FDXS FTK(X)S20/25/35 FVXS FLXS
Ceiling-mounted cassette type Ceiling-mounted built-in type Ceiling-suspended type Duct-connected type Wall-mounted type Floor-standing type Floor/ceiling-suspended dual type
Function listFunction list
FTK(X)S50/60/71
Power-airflow dual flaps
Wide-angle louvres
Vertical auto-swing (up and down)
Horizontal auto-swing (left and right)
3-D airflow
Comfort airflow mode
Indoor unit quiet operation
Night quiet mode
Intelligent eye
Automatic operation (Heat pump only)
Programme dry function
Auto fan speed
Hot-start function (Heat pump only)
Quick warming function (Heat pump only)
Automatic defrosting (Heat pump only)
Inverter powerful operation
Econo mode
Home leave operation
Indoor unit on/off switch
Titanium apatite photocatalytic air-purifying filter
Photocatalytic deodorising filter
Long-life air filter
High-efficiency filter kit (option)
Fresh air intake kit (option)
Wipe-clean flat panel
Filter cleaning indicator
24-hour on/off timer
72-hour on/off timer
Weekly timer
Night set mode
Auto-restart after power failure
Self-diagnosis with digital display
Anticorrosion treatment of outdoor heat exchanger fins
Drain pump mechanism
Ceiling soiling prevention
Comfortable airflow
Comfort control
Lifestyle convenience
Cleanliness
Timers
Worry free
Flexibility
3029
Function dictionaryComfortable Airflow
Comfort Control
Lifestyle Convenience
Cleanliness Timers
Worry Free
Power-Airflow Dual FlapsPower-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.
Wide-Angle LouvresSmoothly curved Wide-Angle Louvres provide wide airflow coverage for effective cooling/heating operation.
Vertical Auto-Swing (up and down)Vertical Auto-Swing automatically moves the flaps up and down to distribute air across a room.
Horizontal Auto-Swing (left and right)Horizontal Auto-Swing automatically moves the louvres to the left and right to cover a room with cool/warm air.
3-D AirflowThis function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool/warm air right to the corners of even large spaces.
Comfort Airflow ModeThis function prevents uncomfortable drafts from blowing directly on to the body. The flap changes the airflow direction. To prevent drafts, the flap moves upward during cooling operation and downward during heating operation.
Titanium Apatite Photocatalytic Air-Purifying FilterUses a Titanium Apatite Photocatalytic Air-Purifying Filter. Titanium apatite is a photocatalytic material with high adsorption power. It effectively adsorbs and removes bacteria. It lasts for 3 years without replacement if washed about once every 6 months.
Photocatalytic Deodorising FilterThis filter decomposes odours and even removes bacteria and viruses. This power is maintained simply by exposing the filter to sunlight once every 6 months.
Long-Life Air FilterMaintenance is not required for one year.
High-Efficiency Filter Kit (option)Two types are available: 65% and 90% colorimetry.
Fresh Air Intake Kit (option)You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.Note: 1. Connecting ducts, insect nets, fire dampers, air
filters, and other parts should, as required, be procured locally.
2. Outside air fan interlocked with air conditioning unit is necessary. Optional PCB (KRP1C63) is required for interlocking.
3. It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending.
Wipe-Clean Flat PanelThe flat panel models can be cleaned with only the single pass of a cloth across their smooth surface. The flat panel can also be easily removed for more thorough cleaning.
Filter Cleaning IndicatorDust deposited on the air filters is not only unhygienic, it also reduces the operating efficiency of the air conditioner. A message indicates when the air filters need cleaning.
24-Hour On/Off TimerThis timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/stopped simply by pressing the On/Off timer button on the wireless remote controller.
72-Hour On/Off TimerThis timer can be set to start and stop at any time within a 72-hour period. Simply press the On timer button, and the air conditioner will automatically start to operate at the preset time.
Weekly TimerThis timer can be preprogrammed with settings for day of the week, time of day, temperature, and operation on/off. A maximum of four air conditioner start or stop points can be entered per day for each of seven days in a one-week period simply by pressing the WEEKLY button.
Night Set ModePressing the Off timer button automatically selects the Night Set Mode. This function prevents excessive cooling or heating for pleasant sleep conditions.
Auto-Restart After Power FailureThe air conditioner memorises the settings for mode, airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.
Self-Diagnosis with Digital DisplayMalfunction codes for each indoor unit are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.
Anticorrosion Treatment of Outdoor Heat Exchanger FinsThe outdoor unit’s heat exchanger fins are processed using a special anticorrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion.
Flexibility
Drain Pump MechanismSteeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
Ceiling Soiling PreventionAir discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.
Indoor Unit Quiet OperationIndoor unit operating sound level is decreased by 2 or 3 dB (A) from the low setting fan speed using the wireless remote controller.
Night Quiet ModeOperation sound level is selectable from 3 steps for the night mode. This function is available in setting at site.
Intelligent EyeIntelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by ± 2˚C for energy savings.
Automatic Operation (Heat pump only)This function automatically selects cooling or heating operation mode based on the room temperature at start-up.
Programme Dry FunctionThis function automatically reduces the level of humidity.
Auto Fan SpeedThe microprocessor automatically controls fan speed to adjust the room temperature to the set temperature.
Hot-Start Function (Heat pump only)After defrosting or when starting heating operation, air is preheated before discharge to prevent uncomfortable cold drafts.
Quick Warming Function (Heat pump only)During low outdoor temperatures, this function preheats the compressor to shorten the time required to discharge warm air.
Automatic Defrosting (Heat pump only)Before starting heating operation, a sensor checks for frost in the outdoor unit and performs automatic defrosting if necessary so that only warm air is discharged.
Function dictionary
Inverter Powerful OperationThis function is convenient for boosting cooling/heating performance for a 20-minute period both when you first turn on your air conditioner and want to quickly change the room temperature.
Econo ModeEcono Mode reduces the maximum running current and maximum power consumption of the outdoor unit to the rated values. This is useful when using multiple air conditioners and other electrical devices at the same time.
Home Leave OperationHome Leave Operation continues operation to prevent a room from becoming too hot or cold while you are sleeping or out of your home. Select any temperature from 18 to 32˚C for cooling operation and 10 to 30˚C for heating operation.
Indoor Unit On/Off SwitchThe unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
31 32
Ceiling-mounted cassette (compact multi flow) type
Outdoor unit
Specifications
Outdoor unit
Model name
Power supply
Capacity (rated)
Total indoor unit capacity
Number of indoor units to be connected
Number of BP to be connected
Casing colour
Compressor
Airflow rate (H)
Refrigerant
Refrigerant oil
Sound level
Sound powerlevel
Dimensions (H x W x D)
Machine weight
Operating range
Number of wiring connections
Piping connections
Max. interunit
piping length
Necessity of additional charge
Max. height difference
Cooling
Heating
Type
Motor output
Cooling
Heating
Type
Charge
Model
Charge
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (brazing)
Total main piping and
branch piping
Total main piping
Total branch piping
Max. length for each room
kW
kW
kW
kg
dB (A)
dB (A)
mm
kg
˚CDB
˚CWB
mm
mm
m
m
m
m
kg/m
m
m
Note: * Refrigerant charge is required. (Chargeless piping length 0 m) Formula for calculation charge: R (kg) R = Total length (m) of liquid pipe size at ø9.5 x 0.054 + Total length (m) of liquid piping size at ø6.4 x 0.022
RMXS112LV1A
11.2
12.5
5.5 to 14.5
6
2.5
52
54
65
67
115
60
RMXS140LV1A
14.0
16.0
7.0 to 18.2
8
3.0
1,767 (3,742)
53
55
66
68
-15 to 15.5
135
80
1 phase, 220-240 V, 50 Hz
Ivory white
Hermetically sealed scroll type
1,767 (3,742)
R-410A
4.0
DAPHNE FVC68D
1.7
1,345 x 900 x 320
125
- 5 to 46
ø9.5
ø19.1
RMXS160LV1A
15.5
17.5
8.0 to 20.8
9
3.5
54
56
67
69
145
90
Between indoor or BP unit and outdoor unit: 30
Between indoor and BP unit: 15
RMKS160LV1A
15.5
—
8.0 to 20.8
9
3.5
—
54
—
67
—
145
90
RMKS140LV1A
14.0
—
7.0 to 18.2
8
3.0
—
53
—
66
—
—
135
80
RMKS112LV1A
11.2
—
5.5 to 14.5
6
2.5
—
52
—
65
—
115
60
Indoor unit
Cooling only Heat pump
55
15
Necessary*
3
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP)
Model name
Power supply
Airflow rate (H)
Sound level*(H/L)
Sound powerlevel (H)
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
Model
Colour
Dimensions (H x W x D)
Weight
mm
kg
Panel (option) 55 x 700 x 700
FFQ35BV1B
167 (353)
—
32/25
—
49
—
FFQ50BV1B
200 (424)
—
36/27
—
53
—
FFQ60BV1B
250 (530)
—
41/32
—
58
—
FFQ25BV1B
150 (318)
—
29.5/24.5
—
46.5
—
FFQ35BV1B
167 (353)
167 (353)
32/25
32/25
49
49
FFQ50BV1B
200 (424)
200 (424)
FFQ60BV1B
250 (530)
250 (530)
FFQ25BV1B
150 (318)
150 (318)
29.5/24.5
29.5/24.5
46.5
46.5
White
36/27
36/27
53
53
41/32
41/32
58
58
286 x 575 x 575
17.5
ø6.4
VP20 (External Dia. 26/Internal Dia. 20)
ø12.7ø9.5
BYFQ60B8W1
2.7
Heat pumpCooling only
2 steps
Microcomputer control
Both liquid and gas pipes
/s(cfm)
Measurement conditions1. Cooling operation data is based on the following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; Equivalent piping length from outdoor unit to BP unit 5m; from BP unit
to each indoor unit 3m; level difference 0m.2. Heating operation data is based on the following conditions: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; Equivalent piping length from outdoor unit to BP unit 5m; from BP unit to
each indoor unit 3m; level difference 0m.3. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
/s(cfm)
1 phase, 220-240 V, 50 Hz
ø9.5 ø12.7
600 x 600
Cooling
Heating
Cooling
Heating
Ceiling-mounted cassette (multi flow) type
Model name
Power supply
Airflow rate (H)
Sound level*
(H/L)
Sound power
level (H)
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Liquid (flare)
Gas (flare)
Drain
mm
kg
FCQ50BVE
250 (530)
—
FCQ60BVE FCQ71BVE
dB (A)
dB (A)
mm
kg
mm
mm
mm
Note: * For 220 V operation.
33/29
—
ø12.7
FCQ35BVE
233 (494)
—
ø9.5
ø6.4 ø6.4ø9.5
ø15.9
ø9.5
ø15.9
35/30
—
Colour
Dimensions (H x W x D)
Weight
Panel (option)
Model
White
40 x 950 x 950
5
FCQ50BVE
250 (530)
250 (530)
FCQ60BVE FCQ71BVEFCQ35BVE
ø9.5
33/29 35/30
33/29 35/30
48
—
50
—
48 50
48 50
317 (671)
317 (671)
ø12.7
Cooling only Heat pump
Both liquid and gas pipes
BYC125K-W1
I.D ø25 x O.D ø32
2 steps
Microcomputer control
1 phase, 220-240 V/220 V, 50/60 Hz
230 x 840 x 840
24
/s(cfm)
Cooling
Heating
233 (494)
233 (494)
317 (671)
—
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
33 34
Ceiling-suspended type
Model name
Power supply
Front panel colour
Airflow rate (H)
Sound level (H/L)
Sound powerlevel (H/L)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
1 phase, 220-240 V, 50 Hz
White
2 steps
Microcomputer control
ø6.4
VP 20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
FHQ60BVV1B
283 (600)
—
39/33
—
55/49
—
195 x 1,160 x 680
27
FHQ50BVV1B
—
38/33
—
54/49
—
25
FHQ35BVV1B
—
37/32
—
53/48
—
24
ø9.5
FHQ60BVV1B
283 (600)
267 (564)
39/33
39/33
55/49
55/49
195 x 1,160 x 680
27
FHQ50BVV1B
38/33
38/33
54/49
54/49
25
FHQ35BVV1B
37/32
37/32
53/48
53/48
24
ø9.5
195 x 960 x 680
217 (458) 217 (458)
217 (458)
195 x 960 x 680
ø12.7 ø12.7
Cooling only Heat pump
/s(cfm)
Ceiling-mounted built-in type
Model name
Power supply
Airflow rate (H)
Sound level*(H/L)
Sound powerlevel (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
FBQ71BV1
317 (670)
—
ø9.5
ø15.9
1 phase, 220-240 V, 50 Hz
41/35
60
2 steps
Microcomputer control
300 x 1,000 x 800
41
I.D ø25 x O.D ø32
Both liquid and gas pipes
FBQ60BV1
283 (600)
—
ø6.4
ø12.7
FBQ71BV1
317 (670)
317 (670)
ø9.5
ø15.9
FBQ60BV1
283 (600)
283 (600)
ø6.4
ø12.7
Cooling only Heat pump
Note: * For 220 V operation.
—
—
41/35
60
mm
kg
Colour
Dimensions (H x W x D)
Weight
Panel (option)
Model BYBS71DJW1
White
55 x 1,100 x 500
4.5
/s(cfm)
Model name
Power supply
Airflow rate (H)
Sound level*
(H/L/SL)
Sound power
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
External static pressure
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
Pa
Duct-connected type <700 mm width>
1 phase, 220-240 V/220-230 V, 50/60 Hz
145 (307)
35/31/29
53
5 steps, quiet and automatic
Microcomputer control
200 x 700 x 620
21
ø6.4
ø9.5
VP 20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
30
CDKS35EAVMA
—
—
—
145 (307)
35/31/29
53
CDKS25EAVMA CDXS35EAVMACDXS25EAVMA
Cooling only Heat pump
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa. Sound level values for bottom-suction operation can be obtained by adding 6 dB (A).
/s(cfm)
Model name
Power supply
Airflow rate (H)
Sound level*
(H/L/SL)
Sound power
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
External static pressure
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
Pa
Duct-connected type <900/1,100 mm width>
1 phase, 220-240 V/220-230 V, 50/60 Hz
5 steps, quiet and automatic
Microcomputer control
ø6.4
VP 20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
40
CDKS50CVMA
200 (424)
—
37/33/31
—
55
—
27
CDKS60CVMA
267 (565)
—
38/34/32
—
56
—
30
35/31/29
—
53
—
25
ø9.5 ø9.5
CDKS35CVMA
167 (353)
—
CDKS25CVMA
158 (335)
—
FDXS50CVMA
200 (424)
200 (424)
37/33/31
37/33/31
55
55
27
FDXS60CVMA
267 (565)
267 (565)
38/34/32
38/34/32
56
56
30
Cooling only Heat pump
200 x 900 x 620 200 x 900 x 620200 x 1,100 x 620 200 x 1,100 x 620
ø12.7 ø12.7
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 40 Pa. Sound level values for bottom-suction operation can be obtained by adding 5 dB (A).
/s(cfm)
35/31/29
35/31/29
53
53
25
ø9.5
FDXS35CVMA
167 (353)
167 (353)
FDXS25CVMA
158 (335)
158 (335)
35 36
Model name
Power supply
Front panel colour
Airflow rate (H)
Sound level
(H/L/SL)
Sound power
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
Floor/Ceiling-suspended dual type
Heat pump
FLXS50GVMA
190 (402)
202 (427)
47/39/36
46/35/33
63
62
FLXS60GVMA
200 (424)
213 (452)
48/41/39
47/37/34
64
63
FLXS35GVMA
143 (304)
163 (346)
38/32/29
39/33/30
54
55
FLXS25BVMA
126 (268)
153 (325)
37/31/28
37/31/29
53
53
Almond white
5 steps, quiet and automatic
Microcomputer control
490 x 1,050 x 200
ø6.4
ø18.0
Both liquid and gas pipes
1 phase, 220-240 V/220-230 V, 50/60 Hz
16 17
ø12.7ø9.5
/s
(cfm)
Floor-standing type
Model name
Power supply
Front panel colour
Airflow rate (H)
Sound level
(H/L/SL)
Sound power
level (H)
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
Heat pump
FVXS35KV1A
142 (300)
157 (332)
39/27/24
39/27/24
48
48
FVXS50KV1A
178 (378)
197 (417)
44/36/32
45/36/32
53
54
ø12.7
White
5 steps, quiet and automatic
Microcomputer control
600 x 700 x 210
14
ø6.4
ø20.0
Both liquid and gas pipes
1 phase, 220-240 V, 50 Hz
/s(cfm)
FVXS25KV1A
137 (290)
147 (311)
38/26/23
38/26/23
47
47
ø9.5
Wall-mounted type
Model name
Power supply
Front panel colour
Airflow rate (H)
Sound level
(H/L/SL)
Sound power
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
Heat pumpCooling only
FTKS25KVMAFTKS20KVMA
White
5 steps, quiet and automatic
Microcomputer control
295 x 800 x 215
ø6.4
ø9.5
I.D. ø14.0/O.D. ø18.0
Both liquid and gas pipes
FTKS35KVMA
188 (399)
—
42/26/23
—
58
—
10
1 phase, 220-240 V/220-230 V, 50/60 Hz
FTXS25KVMAFTXS20KVMA FTXS35KVMA
188 (399)
191 (406)
42/26/23
42/29/26
58
58
10
/s(cfm)
Wall-mounted type
Model name
Power supply
Front panel colour
Airflow rate (H)
Sound level
(H/L/SL)
Sound power
level (H)
Fan speed
Temperature control
Dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid (flare)
Gas (flare)
Drain
dB (A)
dB (A)
mm
kg
mm
mm
mm
Heat pumpCooling only
White
5 steps, quiet and automatic
Microcomputer control
290 x 1,050 x 250
12
ø6.4
ø18.0
Both liquid and gas pipes
1 phase, 220-240 V/220-230 V, 50/60 Hz
FTXS50KAVMA
245 (519)
270 (572)
44/35/32
42/33/30
60
58
FTXS60KAVMA
270 (572)
290 (614)
45/36/33
44/35/32
61
60
FTXS71KAVMA
290 (614)
358 (759)
46/37/34
46/37/34
62
62
ø15.9
FTKS50KAVMA
245 (519)
—
44/35/32
—
60
—
FTKS60KAVMA
270 (572)
—
45/36/33
—
61
—
FTKS71KAVMA
290 (614)
—
46/37/34
—
62
—
ø15.9 ø12.7ø12.7
/s
(cfm)
161 (343)
—
38/25/22
—
54
—
9
161 (343)
175 (371)
38/25/22
39/28/25
54
55
9
37 38
Ceiling-mounted cassette (compact multi flow) type
Decoration panel
Remote controller
Adaptor for wiring*2
Wiring adaptor for electrical appendices*2
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
Replacement long-life filter
Fresh air intake kit
Sealing member of air discharge outlet
Panel spacer
BYFQ60B8W1
BRC1C61
KRP1BA57
KRP4AA53
KRP1BA101
KRCS01-1B
KAFQ441BA60
KDDQ44XA60
KDBH44BA60
KDBQ44BA60A
1
2
3
4
5
6
7
8
9
10
FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1BItemNo.
Notes: *1. Wiring for wired remote controller should be obtained locally.*2. Installation box for adaptor PCB (KRP1BA101) is necessary.
Direct installation type
Wired type*1
Wireless typeHeat pump use
Cooling only use
BRC7E530W
BRC7E531W
Outdoor unit
Ceiling-mounted cassette (multi flow) type
Indoor unit
1
2
Central drain plug
Air direction adjustment grille
KKPJ5F180
KPW945A4
1
2
3
4
5
6
7
8
9
10
11
12
Decoration panel
Panel spacer
Chamber typeWithout T-shaped pipe and fan*1
Fresh air intake kit With T-shaped pipe, without fan*2
Direct installation type*3
High-efficiency filter(Colourimetric method 65%)
(Colourimetric method 90%)
Replacement high-efficiency filter(Colourimetric method 65%)
(Colourimetric method 90%)
High-efficiency filter chamber
Longlife filter
Branch duct chamber
Wired type
Remote controllerWireless type
Heat pump use
Cooling only use
Group control adaptor*4
Wiring adaptor for electrical appendices*4
Installation box for adaptor PCB
BYC125K-W1
KDBP55H160WA
KDDP55D160
KDDP55D160K
KDDJ55X160
KAFP556D80
KAFP557D80
KAFP552H80
KAFP553H80
KDDF55DA160
KAF551KA160
KDJ55K80
BRC1C61
BRC7C612W
BRC7C613W
KRP4AA53
KRP1BA57
KRP1B98
Notes:*1. With a suction chamber. Fresh air intake is from 2 holes on the sides of the connection chamber. (This method should be selected if a wireless remote controller is used.)*2. Without a suction chamber. Fresh air intake is from 2 holes on the connection chamber via a T-shaped pipe connection. (A wireless remote controller cannot be used in this case.)*3. Without a suction chamber. Fresh air intake is directly from a hole on the main unit.*4. Installation box for adaptor PCB (KRP1B98) is necessary.
Options
RMXS160LV1ARMXS140LV1ARMXS112LV1ARMKS160LV1ARMKS140LV1ARMKS112LV1A
FCQ35BVE FCQ50BVE FCQ60BVE FCQ71BVEItem No.
No. Item
Model name
Power supply
Power consumption
Running current
Dimensions (H x W x D)
Machine weight
Number of wiring connections
Piping connections
(Brazing)
Heat insulation
Connectable indoor units
Min. rated capacity of
connectable indoor units
Max. rated capacity of
connectable indoor units
Liquid
Gas
Main
Branch
Main
Branch
mm
kg
mm
mm
mm
mm
W
A
kW
kW
2 ports (connectable to 1-2 indoor units)
BPMKS967A2
7.5
ø6.4 x 2
ø15.9 x 2
3 ports (connectable to 1-3 indoor units)
BPMKS967A3
8
ø6.4 x 3
ø15.9 x 3
1 phase, 220-240 V/220-230 V, 50/60 Hz
10
0.05
180 x 294 (+356*) x 350
ø9.5 x 1
ø19.1 x 1
Both liquid and gas pipes
2.0 kW class to 7.1 kW class
2.0
BP unit
3 ports 2 ports
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP), 4 for interunit wiring (BP-indoor unit)
Note: * Total auxiliary piping length.
20.8 14.2
39 40
Note: * Installation box for adaptor PCB (KRP1CA93) is necessary.
Ceiling-mounted built-in type
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
FBQ60BV1 FBQ71BV1ItemNo.
Decoration panel
Service access panel
High-efficiency filter
Replacement long-life filter
Filter chamber for bottom suction
Filter chamber for rear suction
Canvas duct
Discharge grille
Discharge chamber
Branch duct
Flexible duct
Blind board
Adaptor for discharge
Flange for suction
Remote controller
Adaptor for wiring (Interlock for fresh air intake fan)
Group control adaptor
Wired type
Wireless typeHeat pump use
Cooling only use
BYBS71DJW1
KTBJ25L80W
KAF252LA80
KAF253LA80
KAFJ251K80
KAJ25LA80D
KAJ25LA80B
KSA-25KA80
K-DG5DW
K-DG9DW
K-DGC5D
K-DGC9D
K-DDV20A
KBBJ25KA80
KDAJ25K71
KDJ2507K80
BRC1C61
KRP1BA54
KRP4AA51
K-FDS151C(1m)/K-FDS152C(2m)/K-FDS153C(3m)/K-FDS154C(4m)/K-FDS155C(5m)/K-FDS156C(6m)
K-FDS201C(1m)/K-FDS202C(2m)/K-FDS203C(3m)/K-FDS204C(4m)/K-FDS205C(5m)/K-FDS206C(6m)
(Colourimetric method 65%)
(Colourimetric method 90%)
Resin net
ø150
ø200
ø150
ø200
ø150 ø200
ø150
ø200
Wired type
Ceiling-suspended type
1
2
3
4
5
6
7
FHQ35BVV1B FHQ50BVV1B FHQ60BVV1BItemNo.
Replacement long-life filter
Drain up kit
L-type piping kit (For upward direction)
Remote controller
Adaptor for wiring
Wiring adaptor for electrical appendices*
Installation box for adaptor PCB
FDU50M60VE
BRC1C61
BRC7EA63W
BRC7EA66
KRP1BA54
KRP4AA52
KRP1CA93
KAFJ501DA80KAF501DA56
KHFP5MA63KHFP5MA35
Duct-connected type
1
2
3
4
5
6
7
Wired remote controller*1
Wired remote controller cord
5-room centralised controller*2
Wiring adaptor for time clock/remote controller*3
(Normal open pulse contact/normal open contact)
Wireless remote controller loss prevention chain
Suction grille
Insulation kit for high humidity
Length 3 m (shielded wire)
Length 8 m (shielded wire)
Notes:*1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.*2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.*3. Time clock and other devices should be obtained locally.
BRC944B2
BRCW901A03
BRCW901A08
KRC72
KRP413AB1S
KKF917A4
KDGF19A45
KDT25N63KDT25N50KDT25N32
ItemNo.
Wall-mounted type
BRC944B2
BRCW901A03
BRCW901A08
KRC72
KRP413AB1S
Notes:*1. 3 m (BRCW901A03) or 8 m (BRCW901A08) length wired remote controller cord is necessary.*2. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.*3. Time clock and other devices should be obtained locally.*4. Filter is a standard accessory. It should be replaced approximately every 3 years.
No.
KAF970A46
KKF910A4
BP unit
Control system
No.
1
Item
REFNET joint
BPMKS967A2 BPMKS967A3
KHRP26A22T
No.
1
2
3
4
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor
(For DIII-NET use)
FTK(X)S-K/KA, FVXS-K, FLXS-B/G, CDK(X)S-EA, CDKS-C, FDXS-C
FCQ-B, FFQ-B, FBQ-B, FHQ-B
Model No.
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S
DTA112BA51
Note:* An interface adaptor (KRP928BB2S or DTA112BA51) is also required for each indoor unit.
Note:A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.
Item
Floor-standing type
5-room centralised controller*1
Wiring adaptor for time clock/remote controller*2
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*3
Remote controller loss prevention chain
KRC72
KRP413AB1S
KAF968A42
KKF910A4
1
2
3
4
FVXS35KV1A FVXS50KV1AItemNo. FVXS25KV1A
Notes:*1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.*2. Time clock and other devices should be obtained locally.*3. The photocatalytic deodorising filter is a standard accessory. It can be reused indefinitely if it is exposed to direct sunlight once every 6 months. This accessory is only required if the original filter is damaged or lost, etc.*4. The air-purifying filter is a standard accessory. It should be replaced approximately once every 3 months. This accessory is required for the replacement of filters.
Notes:*1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.*2. Time clock and other devices should be obtained locally.*3. Filter is a standard accessory. It should be replaced approximately every 3 years.
Floor/ceiling-suspended dual type
5-room centralised controller*1
Wiring adaptor for time clock/remote controller*2
(Normal open pulse contact/normal open contact)
Photocatalytic deodorising filter with frame*3
Photocatalytic deodorising filter without frame*3
Air-purifying filter with frame*4
Air-purifying filter without frame*4
Remote controller loss prevention chain
KRC72
KRP413AB1S
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
KKF917A4
1
2
3
4
5
6
7
ItemNo. FLXS25BVMA FLXS35GVMA FLXS50GVMA FLXS60GVMA
Length 3 m (shielded wire)
Length 8 m (shielded wire)
FTXS20KVMA FTXS25KVMA FTXS35KVMA FTXS50KAVMA FTXS71KAVMA
FTKS20KVMA FTKS25KVMA FTKS35KVMA FTKS50KAVMA FTKS71KAVMA
FTXS60KAVMA
FTKS60KAVMA
CDKS25EAVMA
CDXS25EAVMA
CDKS35EAVMA
CDXS35EAVMA
CDKS25CVMA
FDXS25CVMA
CDKS35CVMA
FDXS35CVMA
CDKS50CVMA
FDXS50CVMA
CDKS60CVMA
FDXS60CVMA
Item
Wired remote controller*1
Wired remote controller cord
5-room centralised controller*2
Wiring adaptor for time clock/remote controller*3
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*4
Wireless remote controller loss prevention chain
1
2
3
4
5
6
41 42
Selection Procedure Outdoor unit RMK(X)S160L
Number of indoor units
2 to 9 units
Total indoor unit capacity
8.0 to 20.8 kW
Number of BP units
1 to 3 units
Number of REFNET joints
Number of BP units
123
UnnecessaryKHRP26A22T x 1KHRP26A22T x 2
Indoor unitmodel name Rated capacity (kW)
FTK(X)S-K/KA, FVXS-K, FLXS-B/G, CDK(X)S-EA, CDKS-C, FDXS-C, FCQ-B, FFQ-B, FBQ-B, FHQ-B252.5
202.0
353.5
505.0
606.0
717.1
Capacity Tables
Note:Cooling operation data is based on the following conditions: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values.
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
RMK(X)S112LV1A
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
RMK(X)S140LV1A
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)
RMK(X)S160LV1A
1.992.032.062.102.132.172.202.232.272.302.342.372.412.442.472.512.542.582.612.652.682.712.752.782.822.852.892.922.952.993.023.063.093.133.163.203.233.263.303.333.373.403.443.473.503.543.573.613.643.683.713.743.783.813.85
3.883.923.953.984.024.054.094.124.164.194.224.264.294.334.364.404.434.464.504.534.574.604.644.674.714.754.774.794.804.814.824.834.844.864.874.884.894.904.914.924.944.954.964.974.984.995.005.015.025.035.045.055.065.075.08
5.095.105.115.125.135.145.155.165.175.185.195.205.215.225.235.245.255.265.27
Total indoor unit capacity
(kW)
Cooling capacity
(kW)
Power consumption
(kW)8.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.4
13.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.218.318.418.518.618.718.818.9
19.019.119.219.319.419.519.619.719.819.920.020.120.220.320.420.520.620.720.8
7.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.0
13.113.213.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.515.615.615.615.615.615.615.715.715.715.715.715.715.815.815.815.815.815.815.915.915.915.915.915.916.016.016.016.0
16.016.116.116.116.116.116.116.216.216.216.216.216.216.316.316.316.316.316.4
Cooling capacity Cooling capacity
1.391.421.441.461.491.511.531.561.581.601.631.651.681.701.721.751.771.801.821.851.871.901.921.951.972.002.022.052.082.102.132.152.182.212.232.262.292.312.342.372.392.422.452.482.502.532.562.592.612.642.672.702.732.762.782.812.842.882.912.97
3.033.093.143.203.253.303.353.403.443.483.523.563.603.633.663.693.723.743.773.793.813.833.843.853.873.883.883.893.893.893.89
5.55.65.75.85.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.4
11.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.5
5.65.65.85.95.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.4
11.511.611.711.811.912.012.112.212.312.412.412.512.512.612.612.712.712.812.812.912.913.013.013.013.013.113.113.113.113.113.1
1.861.891.921.951.982.012.042.082.112.142.172.202.232.262.292.322.352.382.412.442.472.502.532.562.592.622.652.682.712.752.782.812.842.872.902.932.962.993.023.053.083.113.143.173.203.233.263.293.323.353.383.423.453.483.513.543.573.603.633.66
3.693.723.753.783.813.843.873.903.933.963.994.034.044.064.084.094.114.124.144.154.174.184.204.214.234.254.264.284.294.314.324.344.354.374.394.404.424.434.454.464.484.494.514.534.544.564.574.594.604.624.634.654.67
7.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.9
13.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.2
7.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.9
13.013.113.213.313.413.513.613.713.813.914.014.114.214.214.314.314.414.414.514.514.614.614.714.714.814.814.814.914.914.915.015.015.015.015.115.115.115.115.115.215.215.215.215.215.215.215.215.315.315.315.315.315.3
43 44
Note:Heating operation data is based on the following conditions: indoor temp. 20˚CDB; outdoor temp. 7˚CDB, 6˚CWB.The rated capacities above show the rise in the total indoor unit capacity when operating frequency is constant. Values for changes in capacity are fixed after accounting for variations in operating frequency and should be used as reference values.
Capacity Tables
1.581.601.621.641.661.681.701.721.741.761.781.801.821.841.861.881.901.921.941.961.982.002.022.042.062.082.112.132.152.172.192.212.232.252.272.292.312.332.352.372.392.412.432.452.472.492.512.532.552.572.592.612.632.652.672.692.722.742.772.80
2.842.872.902.932.952.983.013.033.053.073.093.113.133.143.163.173.183.193.203.213.223.223.233.233.233.233.233.233.233.223.21
Total indoor unit capacity
(kW)
Heating capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Heating capacity
(kW)
Power consumption
(kW)5.55.65.75.85.96.06.16.26.36.46.56.66.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.4
11.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.5
6.76.86.97.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.212.312.412.512.612.7
12.812.913.013.113.213.313.413.513.513.613.613.613.613.613.613.613.713.713.713.713.713.713.713.713.813.813.813.813.813.813.9
RMXS112LV1A
2.072.092.112.132.152.182.202.222.242.262.282.302.322.352.372.392.412.432.452.472.502.522.542.562.582.602.622.642.672.692.712.732.752.772.792.822.842.862.882.902.922.942.962.993.013.033.053.073.093.113.143.163.183.203.223.243.263.293.313.33
3.353.373.393.413.433.463.483.503.523.543.653.663.673.673.683.693.693.703.713.713.723.723.733.743.743.753.763.763.773.783.783.793.803.803.813.823.823.833.843.843.853.863.863.873.883.883.893.893.903.913.913.923.93
Total indoor unit capacity
(kW)
Heating capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Heating capacity
(kW)
Power consumption
(kW)7.07.17.27.37.47.57.67.77.87.98.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.9
13.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.2
8.58.58.68.78.88.99.09.29.39.49.59.69.79.810.010.010.110.210.310.410.610.710.810.911.011.111.211.311.511.611.711.811.912.012.112.212.312.412.512.612.712.813.013.113.213.313.413.513.613.713.813.914.014.114.214.314.514.614.714.8
14.915.015.115.215.315.415.515.615.715.816.016.116.116.116.116.116.116.216.216.216.216.216.316.316.316.316.316.416.416.416.416.416.416.516.516.516.516.516.616.616.616.616.616.616.716.716.716.716.716.816.816.816.8
RMXS140LV1A
Heating capacity Heating capacity
Total indoor unit capacity
(kW)
Heating capacity
(kW)
Power consumption
(kW)
Total indoor unit capacity
(kW)
Heating capacity
(kW)
Power consumption
(kW)
RMXS160LV1A
2.212.232.262.292.312.342.362.392.422.442.472.492.522.552.572.602.622.652.682.702.732.752.782.812.832.862.882.912.942.962.993.013.043.073.093.123.143.173.203.223.253.273.303.333.353.383.403.433.463.483.513.533.563.593.61
3.643.663.693.723.743.773.803.823.853.873.903.933.953.984.004.034.064.084.114.134.164.194.214.244.264.284.314.314.314.314.314.324.324.324.324.324.324.334.334.334.334.334.334.334.344.344.344.344.344.344.344.354.354.354.35
4.354.354.364.364.364.364.364.364.364.374.374.374.374.374.374.384.384.384.38
Total indoor unit capacity
(kW)
Heating capacity
(kW)
Power consumption
(kW)8.08.18.28.38.48.58.68.78.88.99.09.19.29.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.612.712.812.913.013.113.213.313.4
13.513.613.713.813.914.014.114.214.314.414.514.614.714.814.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.017.117.217.317.417.517.617.717.817.918.018.118.218.318.418.518.618.718.818.9
19.019.119.219.319.419.519.619.719.819.920.020.120.220.320.420.520.620.720.8
9.39.49.59.69.79.89.910.010.110.210.310.410.510.610.710.810.911.011.111.211.311.411.511.611.711.811.912.012.112.212.312.412.512.712.812.913.013.113.213.313.413.513.613.713.813.914.014.114.214.314.414.514.614.714.8
14.915.015.115.215.315.415.515.615.715.815.916.016.116.216.316.416.516.616.716.816.917.117.217.317.417.517.517.517.517.517.517.517.517.517.517.517.617.617.617.617.617.617.617.617.617.617.617.617.617.617.617.617.617.617.6
17.617.617.617.617.617.617.617.617.617.617.717.717.717.717.717.717.717.717.7