2
FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp INSTRUCTIONS CM448B © Panduit Corp. 2010 Door Part Number Single Sided Dual Sided PED6 PEVF6 PEV6 PED8 PEVF8 PEV8 PED10 PEVF10 PEV10 PED12 PEVF12 PEV12 PED696 PEVF696 PEV696 PED896 PEVF896 PEV896 PED1096 PEVF1096 PEV1096 PED1296 PEVF1296 PEV1296 Corresponding Vertical Manager Page 1 of 2 PatchRunner TM High Capacity Vertical Doors Part Numbers: PED6, PED8, PED10, PED12, PED696, PED896, PED1096, PED1296 Installation Instructions-Mounting Door to Manager Step 1: Ensure that both handles are in the disengaged position. Handles disengaged Step 2: Set door onto ends of door bracket located on the bottom of the manager. Then ensure that activation tabs on the door bracket fit into windows on the door. Activation Tabs Windows on door Step 3: Fit activation tabs located on the top door bracket into the windows located on top of the door. Activation Tabs Windows on door Handles engaged Step 4: Grasp fingers of manager with fingers and apply thumb to door face. Then squeeze together until handles pop into engaged position.

PatchRunnerTM High Capacity Vertical Doors INSTRUCTIONS … · Corresponding Vertical Manager Page 1 of 2 PatchRunnerTM High Capacity Vertical Doors Part Numbers: PED6, PED8, PED10,

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PatchRunnerTM High Capacity Vertical Doors INSTRUCTIONS … · Corresponding Vertical Manager Page 1 of 2 PatchRunnerTM High Capacity Vertical Doors Part Numbers: PED6, PED8, PED10,

FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp

INSTRUCTIONS CM448B© Panduit Corp. 2010

DoorPart Number Single Sided Dual Sided

PED6 PEVF6 PEV6PED8 PEVF8 PEV8PED10 PEVF10 PEV10PED12 PEVF12 PEV12PED696 PEVF696 PEV696PED896 PEVF896 PEV896PED1096 PEVF1096 PEV1096PED1296 PEVF1296 PEV1296

Corresponding Vertical Manager

Page 1 of 2

PatchRunnerTM High Capacity Vertical DoorsPart Numbers: PED6, PED8, PED10, PED12, PED696, PED896, PED1096, PED1296

Installation Instructions-Mounting Door to ManagerStep 1: Ensure that both handles are in the disengaged position.

Handles disengaged

Step 2: Set door onto ends of door bracket located on the bottom of the manager. Then ensure that activation tabs on the door bracket fit into windows on the door.

Activation Tabs

Windows on door

Step 3: Fit activation tabs located on the top door bracket into the windows located on top of the door.

Activation Tabs

Windows on door

Handles engaged

Step 4: Grasp fingers of manager with fingers and apply thumb to door face. Then squeeze together until handles pop into engaged position.

Page 2: PatchRunnerTM High Capacity Vertical Doors INSTRUCTIONS … · Corresponding Vertical Manager Page 1 of 2 PatchRunnerTM High Capacity Vertical Doors Part Numbers: PED6, PED8, PED10,

INSTRUCTIONS CM448B

For instuctions in Local Languagesand Technical Support:

www.panduit.com/resources/install_maintain.asp

E-mail:[email protected]

Fax:(708)444-6448www.panduit.com

Page 2 of 2

Door Opening Instructions

Opening door to left: Disengage right-hand latch side of door by turning handle in clockwise direction to disengage position, then swing door open to left. Push door to close.

Opening door to right: Disengage left-hand side of door only by turning handle in counterclockwise direction to disengage position, then swing door open to right. Push door to close.

Handle orientation for opening door to left

Handle orientation for opening door to right

Door Removal InstructionsRemoving door: Place both handles in disengage position, then remove door.

Handle orientation for removing door