10
PASSENGER ELEVATORS

PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

PASSENGER ELEVATORS

C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017

Eco Changes is the Mitsubishi Electric Group’s environmental statement,and expresses the Group’s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society.

Visit our website at:http://www.MitsubishiElectric.com/elevator/

Mitsubishi Electric elevators and escalators are currently operating in approximately 90 countries around the globe. Built placing priority on safety first, our elevators, escalators and building system products are renowned for their excellent efficiency, energy savings and comfort. The technologies and skills cultivated at the Inazawa Works and 13 overseas manufacturing factories are utilized in a global network that provides sales, installation and maintenance in support of maintaining and improving product quality.As a means of contributing to the realization of a sustainable society, we consciously consider the environment in business operations, proactively work to realize a low-carbon, recycling-based society, and promote the preservation of biodiversity.

State-of-the-Art Factories…For the Environment. For Product Quality.

Mitsubishi Electric de Mexico, S.A. de C.V. has acquired ISO 9001 certification from the International Organization for Standardization based on a review of quality management.The plant has also acquired the certification of INDUSTRIA LIMPIA, based on the audit of corresponding program.

Certification

Revised publication effective Sep. 2017Superseding publication of C-CL1-6-C9896-A Oct. 2016

Specifications are subject to change without notice.

Page 2: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

1

Based on our policy, “Quality in Motion”,

we provide elevators and escalators that will

satisfy our customers with high levels of

comfort, efficiency, ecology and safety.

Principle

We strive to be green in all of our business activities.We take every action to reduce environmental burden during each process of our elevators’ and escalators’ lifecycle.

Application for Type MR

Contents

… technologically advanced elevators that consume less power,

have minimal impact on the global environment and harmoniously serve people

and buildings with smooth, seamless operation. The refined design produces a

high-quality atmosphere that reassures passengers of the superior safety and

comfort synonymous with Mitsubishi Electric products. Regardless of the use or

purpose, the NEXIEZ is a best-match solution for virtually any elevator installation.

Welcome to a New Era in Vertical TransportationIntroducing the NEXIEZ...

1.75

1.0

(kg)

(m/sec)

Main Features 3-4

Car Designs 5-8

Hall Designs 9-10

Features 11

Entrance Layout Drawing 13-14

Electrical Installation 12

Basic Specifications for Type MR 15-16

Basic Specifications for Type MRL 17-18

450 550 700 750

Application for Type MRL

1.75

1.0

(kg)

(m/sec)

450 630 825

2

NEXIEZ-GPXType MR

NEXIEZ-GPXType MRL

Page 3: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

Our long-term commitment to developing energy-efficient elevators has created systems and functions that make intelligent use of power.

Using Energy WiselyNEXIEZ-GPX comes in two types: configurations with and without machine room (Type MR and Type MRL). Choose the configuration that is better suited for the space and other building conditions.

Flexible Elevator Layout

Emergency Situations

Milestones of Energy-saving Technologies in Elevator Development

Traction machine

Motor drive

Control circuit

Power consumption /CO2 emissions*3

Motor Permanent magnet motor

Gearless

20102000

199019801970

VVVF controlACVV *1 controlAC2 control

MicrocomputerRelay

30%

37%74%93% 100%

*2

Worm geared

Induction motor

–70%Approx.

43

Used for ceiling lights, LEDs boost the overall energy performance of the building. Furthermore, a long service life eliminates the need for frequent lamp replacement.

LED Lighting

Traction Machine with PM Motor (PM motor: Permanent magnet motor)

The joint-lapped core built into the PM motor of the traction machine features flexiblejoints. The iron core acts like a hinge, which allows coils to be wound around the core more densely, resulting in improved motor efficiency and compactness.A high-density magnetic field is produced, enabling lower use of energy and resources and reduced CO2 emissions.

Ceiling: L500

● Advantage of LEDs

Service life (hr) Power consumption (W)

Approximately 20 times longer Approximately 88% reduction

LED

Incandescentlamp

40000

2000

LED

Incandescentlamp

14.4

132

*2

Ceiling: L500 LED downlights

Main Features

The top machine room, accommodating bulky equipment, allows simple and flexible equipment layout to fit the hoistway into a limited space in the building.

All equipment is installed in the hoistway. Without the machine room, the space on the hoistway gives architectures and interior designers greater freedom in design.

Type MR(MR: Machine room)

Type MRL(MRL: Machine-room-less)

Firefighters’ Emergency Operation (FE) (Optional)When the fire operation switch is activated, the car immediately returns to a predetermined floor. The car then responds only to car calls which facilitate firefighting and rescue operations.

Fire Emergency Return (FER) (Optional)When a key switch or a building’s fire alarm is activated, all cars immediately return to a specified floor and open the doors to facilitate the safe evacuation of passengers.

Earthquake Emergency Return (EER-S) (Optional)When a secondary wave seismic sensor is activated, all cars stop at the nearest floor and park there with the doors open to facilitate the safe evacuation of passengers.

Normalpowersupply

Motor

Switch

Emergencypower supply

Control panel

Firefighter

To a specifiedfloor

Normalpowersupply

Motor

Switch

Emergencypower supply

Building’s fire alarmor return signalfrom supervisory room

Control panel

To a specifiedfloor

Normalpowersupply

Motor

Switch

Emergencypower supply

Seismicsensor

Control panel

To the nearestfloor

Page 4: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

Car Designs (1/2)

65 Actual colors may differ slightly from those shown.

N510

The ceiling height of the car shown in this design image is 2600mm.

L500

N530

N520

Car Design ExampleWallsTransom panelDoorsFront return panelsKickplateFlooringCar operating panel

- Brushed stainless-steel- Brushed stainless-steel- Brushed stainless-steel- Brushed stainless-steel- Brushed stainless-steel- M2-F06 [Roca Grafito]- Type LCD

Ceiling: [Center] Brushed stainless-steel [Sides] Painted steel sheet (Black)Lighting: Downlights (LEDs)

Car Design ExampleWalls

Transom panelDoors

Front return panelsKickplateFlooringCar operating panel

Ceiling: [Center] Milky white acrylic panel [Sides] Painted steel sheet (Black)Lighting: [Center] Fluorescent lamp [Sides] Downlights (LEDs)

- Decorative plastic finish : M2-D24 [Chang (RA)]- Brushed stainless-steel- Decorative plastic finish : M2-D24 [Chang (RA)]- Brushed stainless-steel- Brushed stainless-steel- M2-F04 [Terrazo Blanco]- Type LED

Car Design ExampleWalls

Transom panelDoors

Front return panelsKickplateFlooringCar operating panel

- Decorative plastic finish : M2-D16 [Carvalho Cinza (TX)]- Brushed stainless-steel- Decorative plastic finish : M2-D16 [Carvalho Cinza (TX)]- Brushed stainless-steel- Painted steel sheet- M2-F03 [Terrazo Crema]- Type LCD

Ceiling: [Center] Painted steel sheet (Black) [Sides] Painted steel sheet (White)Lighting: [Center] Fluorescent lamp [Sides] Downlights (LEDs)

Car Design ExampleWalls

Transom panelDoors

Front return panelsKickplateFlooringCar operating panel

Ceiling: [Center] Brushed stainless-steel [Sides] Painted steel sheet (Black)Lighting: Fluorescent lamp Downlights (LEDs)

- Decorative plastic finish : M2-D23 [Cherry (MC)]- Brushed stainless-steel- Decorative plastic finish : M2-D23 [Cherry (MC)]- Brushed stainless-steel- Brushed stainless-steel- M2-F05 [Terrazo Humo]- Type LED

L500with center fan type

(Optional)

Page 5: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

Car Operating Panels Materials and Colors

FinishesInterior

87

Notes:*1: Appearing fixing method of face plate is slightly different in elevator type. Please consult our local agents for more details.*2: The entrance width (JJ) shall be 800mm. For JJ=900mm, please consult our local agents.

Buttons accented with LED halo illumination

Illuminated characters (CBV1), arrows (PIV1) and halosattract user’s attention.

YH-59S

YZ-52A

HandrailMirror

Yellow-orange lighting

Tactile

Stainless-steel withnon-directional brushed f inish

Illuminationcolor

M2-D05Titan (TX)

M2-D16Carvalho Cinza (TX)

M2-D19Thuja (LG)

M2-D20American Oak (LG)

M2-D04Silver Oak (MC)

M2-P01Gris Moteado

Base C

M2-P02Gris Verdoso

Moteado

M2-P03AlmendraGofrado

M2-P04Marron

Brillante

M2-P05NaranjaBrillante

M2-P06Rojo Brillante

M2-P07Industrial

Almendra Satinado

M2-P09Verde Brillante

Brushed finish

Walls, doors and Transom panel

Stainless-steel

Decorative plastic finish (only for Walls & doors)

Painted finish

Rubber tile

Vinyl tile

Elevator type

Type MR

P08-2S

All

P11-COP11-2S

P06-2SP08-CO

Front returnpanel

Front returnpanel

Side wallType MRL

Code No.Location of

car operating panel*2*1

Configuration

Car Designs (2/2)

Walls*1

*2

Brushed stainless-steelDecorative plastic f inishPainted steel sheetBrushed stainless-steelPainted steel sheetBrushed stainless-steelDecorative plastic f inishPainted steel sheetBrushed stainless-steelPaintBrushed stainless-steelDurable vinyl tilesDurable rubber tilesMarble (Supplied by customer)Extruded hard aluminum

Application Required Color No.

Transom panel

Doors

Front return panel

Kickplate

Flooring

Sill

Notes: *1: A half-size mirror on the rear wall is available as an option. *2: Only available in dark gray.

- Applicable - Please consult our local agents.

Type LED Type LCD

M2-D21Walnut Minnesota (TX)

M2-D22Sucupira (TX)

M2-D23Cherry (MC)

M2-D24Chang (RA)

M2-D07Nogal (MC)

M2-D25Natura (TX)

M2-D18Almond (TX)

M2-D17Taupe (TX)

Flooring

M2-F01Roca Caliza

M2-F02Roca Ceniza

M2-F03Terrazo Crema

M2-F04Terrazo Blanco

M2-F05Terrazo Humo

M2-F06Roca Grafito

M2-F09Emeflex Rally

Negro

M2-F10Emeflex Rally

Gris

M2-P08Azul Brillante

M2-P10Gris Nopal

Mate

Page 6: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

Brushed finish

Stainless-steel

109

Hall Designs

M2-P01Gris Moteado

Base C

M2-P02Gris Verdoso

Moteado

M2-P03AlmendraGofrado

M2-P04Marron

Brillante

M2-P05NaranjaBrillante

M2-P06Rojo Brillante

M2-P07Industrial

Almendra Satinado

Doors and jamb

Painted finish

Materials and ColorsE-102 Narrow Jamb E-302 Splayed Jamb

PIV1-C710 PIV1-C720 PIV1-C766 PIV1-C776

Hall Position Indicators and Buttons Finishes

JambDoorsHall position indicatorand hall button

- Brushed stainless-steel- Brushed stainless-steel

- PIV1-C710

Jamb

Doors

Hall position indicatorand hall button

- Painted steel sheet : M2-P08 [Azul Brillante]- Painted steel sheet : M2-P08 [Azul Brillante]

- PIV1-A710

JambBrushed stainless-steel

Painted steel sheet

Painted steel sheet

Brushed stainless-steel with logo etchingBrushed stainless-steel

Extruded hard aluminum

Doors

Sill

Application Required Color No.

Note: - Applicable - Please consult our local agents.

PIV1-A710 PIV1-A720

M2-P08Azul Brillante

M2-P09Verde Brillante

M2-P10Gris Nopal

Mate

Page 7: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

Electrical Installation

Power Feeder Data

for Type MR

for Type MRL

Feeder Size Calculation

● The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40°C. 1.25 (Note) × FLU (A)

(FLU (A): current during upward operation with full load at power supply voltage of 200V)Note: For Type MR, the value is 1.05 for the elevator with the rated capacity 700kg or more and the rated speed 1.75m/sec.

The wire length for the feeder size must be calculated via the following formula.Wire length (m) Coefficient* × E (V)/FLAcc (A)(E: power supply voltage (V))(FLAcc (A): current while accelerating with full load at power supply voltage of 200V)

*Refer to the table below for coefficients.

● When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power supply transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are each multiplied by the corresponding diversity factor below.

● The current size of the grounding wire is determined according to the current rating of the NF breaker on the power source side.● The current rating of the NF breaker on the power source side should be one level larger than that on the receiving box side in the elevator machine room or hoistway.

< =

No. of elevators/groupDiversity factor

2

2.0

Feeder size (mm2)Coe�cient

3.5

6.3

5.5

9.7

8

13.8

14

23.9

22

35.9

30

46.4

38

57.6

50

71.3

60

85

80

105

100

126

125

146

150

166

200

192

250

218

325

244

*

Capacity(kg)

Ratedspeed

(m/sec)

Current at 200V

FLU (A) FLAcc (A)

NF size inmachine room

(A)1.01.0

1.751.0

1.751.0

1.75

2.83.45.94.37.64.68.1

16193023382440

26315239654170

4575869

20304030403050

Motoroutput

(kW)

Capacity ofpower supply

(kVA)700850

15001100190012002050

Heatemissions

(W)450

550

700

750

FLU: current during upward operation with full load at power supply voltage of 200V.FLAcc: current while accelerating with full load at power supply voltage of 200V.

Note: If power supply voltage (E) is a value other than 200V, FLU current and FLAcc current are obtained via the following formula. (FLU/FLAcc current (A) at E (V)) = (Current at 200V) × (200/E (V))

Capacity(kg)

Ratedspeed

(m/sec)

Current at 200V

FLU (A) FLAcc (A)1.01.0

1.751.0

1.75

2.83.76.55.18.9

1520332542

2534584475

45769

2030403050

Motoroutput

(kW)

Capacity ofpower supply

(kVA)740960

152011901930

Heatemissions

(W)450

630

825

1211

Features

Notes: • 1C-2BC (1-car selective collective), 2C-2BC (2-car group control) • = Standard = Optional = Not applicable • #1: NS for 1C-2BC: Up to 20 stops, NS for 2C-2BC: Up to 16 stops • #2: Cannot be combined with ITP, EMB. • #3: When ITP is applied, Emergency Alarm Bell is  .

Breaker incontrol panel

(A)

Operational and Service FeaturesFeature Abbreviation 1C-2BC 2C-2BC Required

CCBK -GCBK - -HCBK -CCC -

CFO-A

CLO-A

COS - -EVRC-C

FCC-P

IND -NXL -

NSCR-C

NS

HOS

OLH -SFL -

Group Control Features

Feature Abbreviation 1C-2BC 2C-2BC Required

FFS

TFS

MFP

SOHS - -

Door Operation Features

Feature Abbreviation 1C-2BC 2C-2BC Required

DSAC -DLD -NDG -

DODA -- -

ROHB -RDC -

Signal and Display Features

Feature Abbreviation 1C-2BC 2C-2BC Required

AECC

CID-S

CTBZ

-

-

-

-

-

AAN-G

Emergency Operations and Features

Feature Abbreviation 1C-2BC 2C-2BC Required

Earthquake Emergency Return EER-S

Emergency Car Lighting ECL -Fire Emergency Return FER

Fire�ghters’ Emergency Operation FE

Mitsubishi Emergency Landing Device MELD

Operation by Emergency Power Source – Automatic only OEPS-SA

PIM-C

Next Landing

Non-service to Speci�c Floors – Switch #1

Non-service Temporary Release for Car Call – Card Reader Type

Car Call Canceling

False Call Canceling – Car Button Type

Continuity of Service

Elevator remote control – Car

Car Light Shut O� – Automatic

Car Fan Shut O� – Automatic

Out-of-service by Hall Key Switch

Backup Operation for Car Control Microprocessor

Backup Operation for Group Control Microprocessor

Backup Operation for Hall Control Microprocessor

Safe Landing

Overload Holding Stop

Independent Service

Main Floor ParkingMain Floor Changeover OperationForced Floor Stop

Strategic Overall Spotting

Door Sensor Self-diagnosis

Automatic Door Speed Control

Door Load Detector

Door Nudging Feature – With Buzzer

Repeated Door-close

Multi-beam Door Sensor

Reopen with Hall Button

Car Top Buzzer

Car Arrival Chime – Car

Car LCD Position Indicator

Voice Guidance System

Inter-communication System ITP

Hall LCD Position Indicator

Emergency Alarm Bell #3

#3

Page 8: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

1413

Entrance Layout Drawing

CO (Center Opening) 2S (Side Opening)

E-102

E-102 E-302 E-102 E-302

E-102 E-302 E-102E-102 E-302

4 50

30 55

55 30

38

10100 100

150

Finished wall(by owner)Si

ll su

ppor

t(b

y ow

ner)

Entrance width: JJ

Fini

shW

all

7025 5

10

300

(Min

. cle

aran

ce)

Entra

nce

heig

ht: 2

100

30°

30

55

140

60

E-302

4

30

303055

55

25

80°

Jam

b de

pth:

m

in. 1

30

Finished wall(by owner)

Sill

supp

ort

(by

owne

r)

Entrance width: JJFini

sh

150 150150

Keyhole Keyhole

1200

B

Entrance width:

JJ150

Finishedfloor level

B

120

100

120

100

150

Finishedfloor level

1200

BB

7010 35

20

30°

30

55

140

60

90

300

(Min

. cle

aran

ce)

Entra

nce

heig

ht: 2

100

AA

AA

Door elevation (section A-A)Door plan (section B-B)Door elevation (section A-A)Door plan (section B-B)

Hoistway entranceHoistway entrance

Sill

supp

ort

(by

owne

r)Si

ll su

ppor

t(b

y ow

ner)

(Min

. cle

aran

ce)

(Min

. cle

aran

ce)

E-302

Entra

nce

heig

ht: 2

100

Entra

nce

heig

ht: 2

100

Entra

nce

heig

ht: 2

100

Entrance width: JJ

Entrance width: JJ

Keyhole

JD

70

5

2510

30 140

60

30°

300

7010 35

20

30

9130°

140

60

150

300

150

1200

25

100

100

A

A

BB

91

91 30

25 150

Fini

sh

Jam

b de

pth:

m

in. 1

30

Min. 50

30

75~113

10°

Wall

50

91

91

30

1038

100 100150

Fini

sh

Finished wall(by owner)

Finished wall(by owner)

Finishedfloor level

Entrance width:

JJ

Entra

nce

heig

ht: 2

100

Keyhole

1200

B

150

B

100

100

A

A

Finishedfloor level

Entrance width:

JJ

Entra

nce

heig

ht: 2

100

Entra

nce

heig

ht: 2

100

Entrance width:

JJ

Page 9: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

Horizontal Dimensions

Reaction Loads

1615

Basic Specifications for Type MR

Hoistway Plan

Hoistway width: AH

Entrancewidth: JJ

Car internalwidth: AA

Car i

nter

nal

dept

h: B

B

Hoi

stw

ay d

epth

: BH

JJ

AA

AH

BHBB

Machine Room Plan

2122202422252325222522262627282929

Rear

SideRearSideRearSideRearSideRearSideRearSideRearSide

Side

1616141915171516151716191920212223

2122222425242625242525262627292930

991110121013912913101111121313

53 46

61 51

61 52

61 51

61 52

70 58

68 56

77 64

1400×850

1100×1100

1400×1030

1100×1400

1400×1250

1350×1400

450

550

700

750

6

8

10

11

1.0

1.0

1.75

1.0

1.75

1.0

1.75

1.01.75

800*1

800

800*1

800

800*1

800

CO

2S

CO

2S

CO

2S

1400×850

1100×1100

1400×1030

1100×1400

1400×1250

1350×1400

1750×14001600×17501800×15301750×15902100×14601600×20501800×18301750×18102100×16002050×1800

RearRear*2

Side*2

RearSide

Rear*2

Side*2

RearSideSide

1850×27001800×29801850×20501850×29002100×20501800×32801850×22001850×31002100×20502050×2200

□□□□□□□□□□

P6

P8

P10

P11

6

8

10

11

450

550

700

750

1.0

1.01.75

[Terms of the table]• This table shows standard specifications without counterweight safety. Please consult our local agents for other specifications.[Note]*1: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.

Vertical Dimensions

1.01.75

2200 2500*16070

44004630

13601410

450, 550, 700, 750550, 700, 750

1.01.75

202200 2500*16070

44004630

13601410

450, 550, 700, 750550, 700, 750

[ Terms of the table]• This table shows standard specifications without the fireproof landing door and counterweight safety. Please consult our local agents for other specifications.• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.• Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.[Notes]*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local aqents for details.*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.

Required

Counter-weight

position

Reaction loads(kN)

R1 R2 R3 R4 R5 R6

Shown for CO doorsCounterweight rear drop

Shown for 2S doorsCounterweight rear drop

Shown for 2S doorsCounterweight side drop

R1

R3

R2

R4

Machine room clear width: AM

Machine room clear width: AM

Machine room clear width: AM

R1

R2

R3

R4

Mac

hine

room

dep

th: B

M

Control panel

Power-receiving box (by owner)

Lighting outlet (by owner)

Lighting outlet (by owner)

Lighting outlet (by owner)

Power outlet (by owner)

Power-receiving box (by owner)

Power outlet (by owner)

Power outlet (by owner)

Acc

ess

door

Wid

th: 7

00H

eigh

t: 2

000

Acc

ess

door

Wid

th: 7

00H

eigh

t: 2

000

Access doorWidth: 700

Height: 2000

Mac

hine

room

dep

th: B

MM

achi

ne ro

om d

epth

: BM

Vent

ilati

on

grill

eVe

ntila

tion

gr

ille

Ventilator(by owner)

Ventilator(by owner)

Ventilator(by owner)

データ不明

R1

R2

R3

R4

JJ

AH

BH BB

AA

Hoistway Section

Mac

hine

roo

m c

lear

hei

ght:

HM

2200

Ove

rhea

d: O

H

Entr

ance

hei

ght:

HH

2100

(sta

ndar

d)

Cei

ling

heig

ht23

00 (s

tand

ard

)

Trav

el: T

R

Floo

r to

floo

r he

ight

Pit

dep

th: P

D

R5 R6

Note: Hoistway section for counterweight side    drop is slightly different from this figure.

Power-receiving box (by owner)

Ventilation grille

Control panel

Control panel

R5

R5R6

R6

R5

R6

Page 10: PASSENGER ELEVATORS...PASSENGER ELEVATORS C-CL1-6-C9896-B INA-1709 Printed in Japan (IP) 2017 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses

1817

Basic Specifications for Type MRL

Horizontal Dimensions

[ Terms of the table]• This table shows standard specifications without the fireproof landing door and counterweight safety. Please consult our local agents for other specifications.• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.• Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.[Notes]*1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local agents for details.*2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details.

800

800*

800*

2SCO2SCO2S

950×1300

1100×1400

1350×1400

1500×17401800×17201650×18002025×17201900×1800

Side

P6

P8

P11

6

8

11

450

630

825

1.0

1.01.75

Reaction Loads

Vertical Dimensions

314348

233335

182628

618092

526876

223235

950×13001100×14001350×1400

450630825

6811

1.01.0

1.75

[ Terms of the table]• This table shows standard specifications without counterweight safety. Please consult our local agents for other specifications.[Notes]*1: If the capacity is 630kg and marble (supplied by customer) is selected for flooring finish, the dimension may be changed. Please consult our local agents for details.*2: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.

1.0

1.75

2500*2

TR 3030 TR 60

TR 3030 TR 60

3850*1

3900*1

39003950

405041004150

145015001550

1300*1

135020

450, 630

825

450, 630, 825

<=

<=

<=

<=

<

<TR 30

30 TR 6060 TR 70

<=<=<<=<

□□□□□

Required

Reaction loads(kN)

R1 R2 R3 R4 R5 R6

Shown for 2S doors Counterweight side drop

Shown for CO doors Counterweight side drop

Hoistway width: AH

Car i

nter

nal

dept

h: B

B

Hoi

stw

ay d

epth

: BH

Entrancewidth: JJ

Car internalwidth: AA

AH

BB BH

JJ

AA

R5

R5

R1

R1

R2

R2

R3

R3

R4

R4

R6

R6

Ceili

ng h

eigh

t23

00 (s

tand

ard)

Floo

r to

floor

hei

ght

Pit d

epth

: PD

Ove

rhea

d: O

H

Entr

ance

hei

ght:

HH

2100

(sta

ndar

d)

Trav

el: T

R

R5 R6

Hoistway Plan Hoistway Section