Page 2 of 19 Test Report No. E65977-1

Contents Page 1. GENERAL ·············································································································· 3 2. TEST SITE ·············································································································· 3 2.1 LOCATION ······························································································· 3 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS ························ 3 3. DESCRIPTION OF THE TESTED SAMPLE ························································ 4 3.1 RATING ···································································································· 4 4. MEASUREMENT CONDITION ············································································ 4 to 5 4.1 MODE OF OPERATION ··········································································· 4 4.2 ADDITIONAL EQUIPMENT ···································································· 4 4.3 TEST SETUP ···························································································· 5 5. TEST RESULTS EMISSION ··············································································· 6 to 8 5.1 ENCLOSURE PORT ················································································· 6 5.1.1 Electromagnetic Radiation Disturbance ········································ 6 5.2 AC POWER PORT ···················································································· 7 to 8 5.2.1 Mains Terminal Continuous Disturbance Voltage ·························· 7 5.2.2 Harmonic Current········································································ 8 5.2.3 Voltage Fluctuations and Flicker ·················································· 8 APPENDIX A : PHOTOGRAPHS OF THE TEST SETUP ········································ 9 to 10 APPENDIX B : LIST OF TEST AND MEASUREMENT INSTRUMENTS ············· 11 to 12 APPENDIX C : EMI TEST DATA ·············································································· 12 to 19

Page 3: Page 3 of 19 - LIBEREK

Page 3 of 19 Test Report No. E65977-1

1. General

This report describes the emission against disturbances of the tested product. If the tested product will be used with additional equipment other than those mentioned in this report or if tested product will be used against the manufacturer’s specification, the compliance with relevant standards for the system needs to be ensured.

2. Test Site 2.1 Location Cosmos Corporation EMC Lab. No. 2 519 Shimesasu, Watarai-cho, Watarai-gun, Mie-ken 516-2119, Japan Test Specification: EN 301 489-03 V1.4.1 EN 301 489-01 V1.6.1 EN 55022:2006 (Class B) EN 61000-3-2:2000 + A2:2005 EN 61000-3-3:1995 + A1:2001 + A2:2005 Note: The test is in accordance with CISPR 16-1 and CISPR 16-2 for the measurement of

radio interference. 2.2 List of Test and Measurement Instruments Refer to Appendix B.

Page 4: Page 3 of 19 - LIBEREK

Page 4 of 19 Test Report No. E65977-1

3. Description of the Tested Sample

MITSUBISHI ELECTRIC CORPORATION Kyoto Works, Model CP3800DW, CP3800DW-X (referred to as EUT in this report) is Digital Color Printer. 3.1 Rating

Rated Voltage Rated Frequency Rated Current AC 220-240 V 50/60 Hz 1.7 A

Note: Input power condition during the measurement was AC 230 V, 50 Hz. 4. Measurement Condition

4.1 Mode of Operation Mode of operation: Continuous Operating 4.2 Additional Equipment

The equipment was tested together with additional peripherals. The following peripherals were used during the tests:

Instrument Model No. Serial No. Rated Voltage Rated Current

Personal Computer Dimension 4100 HTZD31S AC 115/230 V 6/3 A Monitor AB502 64212600AJ AC 100-240 V 0.9-0.4 A

Keyboard KB-9919 0661565 DC 5 V 200 mA Mouse M-S69 LZE10757869 DC 5 V 25 mA

Page 5: Page 3 of 19 - LIBEREK

Page 5 of 19 Test Report No. E65977-1

4. Measurement Condition (Continued)

4.3 Test Setup

Instrument Model Cable Length Shield A EUT CP3800DW, CP3800DW-X a AC Power Cord 1.9 m × B Personal Computer Dimension 4100 b AC Power Cord 2.0 m × C Monitor AB502 c AC Power Cord 2.0 m × D Keyboard KB-9919 d USB Cable 3.0 m E Mouse M-S69 e Keyboard Cable 1.8 m f Mouse Cable 1.8 m g Monitor Cable 1.7 m

Excess cable arrangement (Radiated Emission)

Sym. Bundle (Length / Position) Hung d, g 0.3 m / center

Excess cable arrangement (Conducted Emission)

Sym. Bundle (Length / Position) Hung a 0.3 m / center ×

d, g 0.3 m / end

Power Supply AC 230V, 50Hz

Power Supply AC 100V, 60Hz

A B C

E D

a b c

d g

e f

Ferrite Core Ferrite Core (E04SR200935A, SEIWA)

Page 6: Page 3 of 19 - LIBEREK

Page 6 of 19 Test Report No. E65977-1

5. Test Results Emission Result: PASS 5.1 Enclosure Port 5.1.1 Electromagnetic Radiation Disturbance (Radiated Emission) Result: PASS In the frequency range from 30 MHz to 1 GHz, the electric field strength was measured according to EN55022:2006. The test setup was made according to EN55022:2006 on the turntable installed in dome at open-site. The wooden non-conductive table, 0.8 m high, was placed on the center of the turntable, and the EUT was put on the table. The measurement was carried out with both horizontal and vertical antenna polarization. The turntable was fully rotated. The highest radiation from the equipment was recorded. By varying the configuration of the test sample and the cable routing, it was attempted to maximize the emission. For further description of the configuration, refer to the pictures of this report. Distance between equipment and antenna: 10 m Height of antenna: 1 - 4 m

Mode of operation: Continuous Operating Uncertainty of measurement result: ± 3.062 dB For more details of the test results, refer to Appendix C, EMI Test Data.

Page 7: Page 3 of 19 - LIBEREK

Page 7 of 19 Test Report No. E65977-1

5.2 AC Power Port 5.2.1 Mains Terminal Continuous Disturbance Voltage (Conducted Emission) Result: PASS The mains terminal continuous disturbance voltage in the frequency range from 0.15 to 30MHz was measured according to EN55022:2006. The measurement setup was made according to EN55022:2006 in a shielded room. The EUT was placed on the non-conductive table in 0.8m distance from the horizontal reference ground plane. The used line impedance stabilizing network (LISN) has a rated impedance of 50Ω/50µH as specified in CISPR 16-1. The test receiver with Quasi Peak and Average detector is in compliance with CISPR 16-1. If the result of the measurement with the Quasi Peak detector was lower than the Average limit, the measurement with Average detector was omitted.

Mode of operation: Continuous Operating Uncertainty of measurement result: ± 2.26 dB For more details of the test results, refer to Appendix C, EMI Test Data.

Page 8: Page 3 of 19 - LIBEREK

Page 8 of 19 Test Report No. E65977-1

5.2.2 Harmonic Current Result: PASS The harmonic current up to 40th order was measured according to EN61000-3-2:2000 + A2:2005. Mode of operation: Continuous Operating

For more details of the test results, refer to Appendix C, EMI Test Data. 5.2.3 Voltage Fluctuations and Flicker Result: PASS The voltage fluctuations and flicker was measured according to EN61000-3-3:1995 + A1:2001 + A2:2005. Mode of operation: Continuous Operating For more details of the test results, refer to Appendix C, EMI Test Data.

Page 9: Page 3 of 19 - LIBEREK

Page 9 of 19 Test Report No. E65977-1

Appendix A: Photographs of the Test Setup

Radiated Emission

Front View

Rear View

Page 10: Page 3 of 19 - LIBEREK

Page 10 of 19 Test Report No. E65977-1

Appendix A: Photographs of the Test Setup (Continued)

Conducted Emission

Front View

Side View

Page 11: Page 3 of 19 - LIBEREK

Page 11 of 19 Test Report No. E65977-1

Appendix B: List of Test and Measurement Instruments

Radiated Emission

Instruments Manufacturer Model Serial No.

Calibrated Date/Until

Spectrum Analyzer HEWLETT PACKARD 8563E 3846A10015

July, 2007 July, 2009

EMI Test Receiver ROHDE & SCHWARZ ESCS30 830245/014

April, 2007 April, 2009

Pre-Amplifier HEWLETT PACKARD 8447D OPT 011 2944A08750

July, 2007 July, 2008

Biconical Log-periodic Antenna

SCHAFFNER CHASE EMC LTD

CBL6111C 2612

May, 2007 May, 2008

OATS Cosmos Corp. Cosmos Corp. No.2

July, 2007 July, 2008

RF cable SUHNER RG214/U C1/C2/C3/C4/C5

May, 2007 May, 2008

RF Selector TOYO Corporation NS4901DR 9904011

Confirmed before Test

Conducted Emission

Instruments Manufacturer Model Serial No.

Calibrated Date/Until

Spectrum Analyzer HEWLETT PACKARD 8563E 3846A10015

July, 2007 July, 2009

EMI Test Receiver ROHDE & SCHWARZ ESCS30 830245/014

April, 2007 April, 2009

Artificial-Mains Network (for EUT)

KYORITSU CORPORATION

KNW-243C 8-1238-3

September, 2007 September, 2008

Artificial-Mains Network (for Peripheral) ROHDE & SCHWARZ ESH2-Z5

828739/005 June, 2007 June, 2008

RF cable SUHNER RG223/U (4m)

May, 2007 May, 2008

RF Selector TOYO Corporation NS4901DR 9904011

Confirmed before Test

Transient Limiter CHASE Electronics Limited

CFL9206 1662

Confirmed before Test

Page 12: Page 3 of 19 - LIBEREK

Page 12 of 19 Test Report No. E65977-1

Appendix B: List of Test and Measurement Instruments (Continued) Harmonic Current Voltage Fluctuations and Flicker

Instruments Manufacturer Model Serial No.

Calibrated Date/Until

System Power Supply NF Corporation 8461 + 4437 328019 + 326216

Confirmed before Test

Reference Impedance Network NF Corporation 4151 323515

Confirmed before Test

Power Analyzer VOLTECH PM6000 100006700093

December, 2006 December, 2007

Appendix C: EMI Test Data

I) Total 7 Pages: Page 13 to 19

Radiated Emission ··························· Page 13 to 14 Conducted Emission ·························· Page 15 to 16 Harmonic Current ······························ Page 17 to 18 Voltage Fluctuations and Flicker ····· Page 19

II) Calculation

Result = Reading + c.f. Margin = Limit - Result

Page 13: Page 3 of 19 - LIBEREK

Page 13 of 19 Test Report No. E65977-1

Appendix C: EMI Test Data (Continued) Radiated Emission *************************************** Cosmos Corporation *********************************** <<Radiated Emission -EP5/RE Ver2.0.910->> 5 November,2007 10:04 065973E RE Total10.dat Limit : EN55022 Class B 10mModel : CP3800DWSerial : DS8X7A000510Operator : J.TakashibaPower : AC 230V, 50HzTemp , Humid : 27deg., 40%Remark1 : OperatedRemark2 : Remark3 : Remark4 : RBW: 120kHz************************************************************************************************Final Result

--- Horizontal Polarization (QP)---No. Frequency Reading c.f Result Limit Margin Height Angle [MHz] [dB(μV)] [dB(1/m)] [dB(μV/m)] [dB(μV/m)] [dB] [cm] [°] 1 52.388 26.7 -17.0 9.7 30.0 20.3 399.3 119.0 2 108.922 24.7 -13.0 11.7 30.0 18.3 399.3 291.0 3 173.117 25.1 -14.3 10.8 30.0 19.2 397.0 239.0 4 257.642 26.2 -9.7 16.5 37.0 20.5 396.0 240.0 5 408.722 21.1 -5.8 15.3 37.0 21.7 394.0 199.0

--- Vertical Polarization (QP)---No. Frequency Reading c.f Result Limit Margin Height Angle [MHz] [dB(μV)] [dB(1/m)] [dB(μV/m)] [dB(μV/m)] [dB] [cm] [°] 1 44.457 34.7 -14.5 20.2 30.0 9.8 101.0 59.0 2 51.564 30.4 -16.8 13.6 30.0 16.4 103.0 121.0 3 70.033 23.4 -18.2 5.2 30.0 24.8 102.0 233.0 4 174.430 29.1 -14.4 14.7 30.0 15.3 102.0 160.0 5 257.640 31.5 -9.7 21.8 37.0 15.2 105.0 244.0 6 327.347 20.9 -8.1 12.8 37.0 24.2 102.0 296.0 7 408.133 31.5 -5.8 25.7 37.0 11.3 107.0 212.0

Page 14: Page 3 of 19 - LIBEREK

Page 14 of 19 Test Report No. E65977-1

Appendix C: EMI Test Data (Continued) Radiated Emission

Cosmos Corporation- EMC Site -

5 November,2007 10:04065973E RE Total10.dat

<<Radiated Emission -EP5/RE Ver2.0.910->>

Limit : EN55022 Class B 10mModel : CP3800DWSerial : DS8X7A000510Operator : J.TakashibaPower : AC 230V, 50HzTemp , Humid : 27deg., 40%

Remark1 : OperatedRemark2 : Remark3 : Remark4 : RBW: 120kHz

30 100050 100 5000

60

10

20

30

40

50

Frequency

Level

[MHz]

[dB(μV/m)]

<EN55022ClassB10m>Limit Line

<065973E RE Total10>LEVEL(H,QP)

Cosmos Corporation- EMC Site -

5 November,2007 10:04065973E RE Total10.dat

<<Radiated Emission -EP5/RE Ver2.0.910->>

Limit : EN55022 Class B 10mModel : CP3800DWSerial : DS8X7A000510Operator : J.TakashibaPower : AC 230V, 50HzTemp , Humid : 27deg., 40%

Remark1 : OperatedRemark2 : Remark3 : Remark4 : RBW: 120kHz

30 100050 100 5000

60

10

20

30

40

50

Frequency

Level

[MHz]

[dB(μV/m)]

<EN55022ClassB10m>Limit Line

<065973E RE Total10>LEVEL(V,QP)

Page 15: Page 3 of 19 - LIBEREK

Page 15 of 19 Test Report No. E65977-1

Appendix C: EMI Test Data (Continued) Conducted Emission

******************************************* Cosmos Corporation *************************************** <<Conducted Emission -EP5/CE Ver2.0.910->> 6 November,2007 13:58 065973E CE Total17.datLimit : EN55022 Class BModel : CP3800DWSerial : DS8X7A000510Operator : J.TakashibaPower : AC230V 50HzTemp , Humid : 18 deg.,55%Remark1 : OperatedRemark2 : Remark3 : Remark4 : RBW:9kHz********************************************************************************************************Final Result

--- N Phase ---No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP AV QP AV QP AV QP AV [MHz] [dB(μV)] [dB(μV)] [dB] [dB(μV)] [dB(μV)] [dB(μV)] [dB(μV)] [dB] [dB] 1 0.155 46.9 36.7 11.3 58.2 48.0 65.7 55.7 7.5 7.7 2 0.259 19.5 13.3 10.5 30.0 23.8 61.5 51.5 31.5 27.7 3 0.473 21.4 20.0 10.1 31.5 30.1 56.5 46.5 25.0 16.4 4 4.017 35.3 27.4 10.5 45.8 37.9 56.0 46.0 10.2 8.1 5 11.894 11.1 4.5 11.6 22.7 16.1 60.0 50.0 37.3 33.9 6 27.466 11.1 1.9 13.0 24.1 14.9 60.0 50.0 35.9 35.1

--- L1 Phase ---No. Frequency Reading Reading c.f Result Result Limit Limit Margin Margin QP AV QP AV QP AV QP AV [MHz] [dB(μV)] [dB(μV)] [dB] [dB(μV)] [dB(μV)] [dB(μV)] [dB(μV)] [dB] [dB] 1 0.153 47.3 38.0 11.2 58.5 49.2 65.8 55.8 7.3 6.6 2 0.206 33.2 26.7 10.6 43.8 37.3 63.4 53.4 19.6 16.1 3 0.250 18.9 17.9 10.3 29.2 28.2 61.8 51.8 32.6 23.6 4 0.520 9.9 1.6 9.9 19.8 11.5 56.0 46.0 36.2 34.6 5 3.809 35.0 28.1 10.2 45.2 38.3 56.0 46.0 10.8 7.7 6 11.894 15.1 7.2 11.8 26.9 19.0 60.0 50.0 33.1 31.0

Page 16: Page 3 of 19 - LIBEREK

Page 16 of 19 Test Report No. E65977-1

Appendix C: EMI Test Data (Continued) Conducted Emission

Cosmos Corporation-- EMC --

6 November,2007 13:58065973E CE Total17.dat

<<Conducted Emission -EP5/CE Ver2.0.910->>

Limit : EN55022 Class BModel : CP3800DWSerial : DS8X7A000510Operator : J.TakashibaPower : AC230V 50HzTemp , Humid : 18 deg.,55%

Remark1 : OperatedRemark2 : Remark3 : Remark4 : RBW:9kHz

0.15 30.000.50 1.00 5.00 10.000

90

10

20

30

40

50

60

70

80

Frequency

Level

[MHz]

[dB(μV)]

<EN55022ClassB>Limit Line (QP)Limit Line (AV)

<065973E CE Total17>Range (N,PK)

Cosmos Corporation-- EMC --

6 November,2007 13:58065973E CE Total17.dat

<<Conducted Emission -EP5/CE Ver2.0.910->>

Limit : EN55022 Class BModel : CP3800DWSerial : DS8X7A000510Operator : J.TakashibaPower : AC230V 50HzTemp , Humid : 18 deg.,55%

Remark1 : OperatedRemark2 : Remark3 : Remark4 : RBW:9kHz

0.15 30.000.50 1.00 5.00 10.000

90

10

20

30

40

50

60

70

80

Frequency

Level

[MHz]

[dB(μV)]

<EN55022ClassB>Limit Line (QP)Limit Line (AV)

<065973E CE Total17>Range (L1,PK)

Page 17: Page 3 of 19 - LIBEREK

Page 17 of 19 Test Report No. E65977-1

Appendix C: EMI Test Data (Continued) Harmonic Current

Page 18: Page 3 of 19 - LIBEREK

Page 18 of 19 Test Report No. E65977-1

Appendix C: EMI Test Data (Continued) Harmonic Current

Page 19: Page 3 of 19 - LIBEREK

Page 19 of 19 Test Report No. E65977-1

Appendix C: EMI Test Data (Continued) Voltage Fluctuations and Flicker