Page 1 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

MXL/MXL-IQ to FireFinder XLS Total Migration Solution

Page 2 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Intro

Siemens is in the process of developing a MXL to FireFinder XLS total migration solution

Page 3 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Topics

Why migrate existing installations?

Advantages of Siemens MXL to XLS migration solution

What MXL installations should be targeted for migration?

How to estimate a migration opportunity

Page 4 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Why start the rollout now?

Customer awareness of the ability to migrate

Protection of your installed base

Sales Cycle can take up to 18 months

Customer needs time to plan for upgrade

Must align with customer budget cycle / funding ability

Page 5 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Why Migrating MXL systems is a good business opportunity

It is estimated that over 70,000 MXL systems have been sold since MXL was introduced in 1992

Early installed systems are prime candidates for migration

Minimizes competition via cost and time effective solution

Profitable business and a win-win solution (sales outlet and end user)

Page 6 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

The components used in legacy fire alarm systems become difficult to secure, resulting in higher maintenance costs

Replacement parts become more expensive or unobtainable

Fire alarm system down for long periods of time.

Siemens provides a cost effective migration solution to modernize the fire alarm system in phases while staying within the customer’s budget

FireFinder XLS uses more advanced technology

FireFinder XLS is an enabler for future technology

How do you convince a customer to modernize a system?

Page 7 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Features of the MXL to XLS migration solution

MXL Line Card (MLC) that allows XLS to communicate to existing ALD devices

Enclosure adapters that allow XLS components to fit into existing MXL and MXL-IQ backboxes MSE-2, MSE-2R, MME-3, MME-3R, MBR-2, MLE-6, MLE-6R, MSE-3M, MSE-3MR, MSE-3L, MSE-3LR

Enclosure adapters that allow SSD to fit into remote annunciator backboxes RCC-1, RCC-3, RCC-3R, RCC-1F, RCC-3F, RCC-3FR

Ability to import MXL device custom message database into XLS programming tool which reduces programming time

Page 8 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Advantages

Competitive cost advantage for replacement of installed MXL systems due to ability to keep existing field devices and wiring

Less downtime for fire alarm system during migration

Ability to use existing backbox which eliminates an additional cut-out in the wall

Reduced programming time, reduces labor costs

Gets the customer’s solution accomplished faster than any competitor’s approach

Advanced system with improved response time that is easier to maintain

Page 9 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

MXL Configurations to Target

Single node MXL

MXL-IQs without high levelVESDA interface

Single node MXL with transponders

Single node MXLV Voicewith transponders

Networked MXLs

MXL to XLS interpanel logic is not supported (Proper Planning is required)

Page 10 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

MXL with XLDs

XLD Loops are required to be replaced with DLCs and H series devices

Please consult Florham Park to ensure DLC and MLC circuits can be run in the same conduit

DLC could cause noise on the MLC circuit with distances over 2000 ft when Unshielded, Untwisted wire is used!

Page 11 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

MXL Configurations to Not Target at this time

MXL-IQs with high level VESDA interface

Networked MXLVs with RCMs

MXLVs with more than 4 prerecorded digital messages or spoken zone coding

MXL(V)s connected to Apogee Insight

MXLs connected to NCC-WAN via the HUB-4/CMI-300

MXL installations requiring FM or US Coast Guard approval

Page 12 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

MLC (MXL Line Card for FireFinder XLS)

Optional card for the FireFinder XLS panel utilizing the ALD Model "I" Series; Model "ID" Series; Model "IL" Series or Model "FP" Series type intelligent devices

Each card supplies 2 circuits

Each circuit supports 60 intelligent (addressable) devices

Each MLC supports 120 devices

Fits in XLS CC-5 or CC-2 card cage

Allows FireFinder XLS headend to use existing field devices and wiring

Consult XLS Wiring Compatibility Guide P/N 315-034786 found on Tech Support website

Page 13 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Adapter for MSE-2 Small Enclosures

Includes Adapter Plate, Inner Door and Outer Door

Required CAB-MP sold separately

Space for up to BTX-1 31 AH Batteries

Space for one PTB

Keep the same backbox.Keep the same field wiring.Keep the same field devices.

CAB-MP

Adapter Plate

Page 14 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Adapter for MME-3/MBR-2 Medium Enclosures

Keep the same backbox.Keep the same field wiring.Keep the same field devices.

Includes Adapter Plate, Inner Door and Outer Door

Required CAB-MP(s) sold separately

Space for up to BTX-1 31 AH Batteries

Space for one PTB CAB-MP

CAB-MP

Adapter Plate

Page 15 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Adapter for MLE-6 Large Enclosures

Keep the same backbox.Keep the same field wiring.Keep the same field devices.

Includes Adapter Plate, Inner Door and Outer Door

Space for up to BTX-1 31 AH Batteries

Required CAB-MP(s) sold separately

Space for two PTBs

Page 16 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Enclosure Adapter for MXL-IQ MSE-3M and MSE-3L Backbox

Keep the same backbox.Keep the same field wiring.Keep the same field devices.

Includes Adapter Plate, Inner Door, Outer Door and Lens Plate

Space for up to 18 AH Batteries (Ensure batteries can take 5A charge!) Werker brand P/N WKA12-18NB

Page 17 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Remote Annunciator Enclosure Adapter for Flush Mount RCC-1F and RCC-3F

Keep the same backbox.Keep the same field wiring.

Includes Adapter Plate and Outer Door

Page 18 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Remote Annunciator Enclosure Adapter for Surface Mount RCC-1

Keep the same backbox.Keep the same field wiring.

Includes Adapter Plate and Door Plate

Page 19 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Database Import Capability

Import MXL CSGM device custom messages and properties into FireFinder XLS Zeus Windows based programming tool

Greatly reduces programming time

Page 20 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Other reasons to upgrade to FireFinder XLS

Innovative electrical and software features allow the panels to be installed faster than competition – This also results in reduced maintenance.

Reduced cabling and removable terminal blocks

Diagnostic LEDs

Windows based configuration tool

The XLS offers new and superior industry-leading features, such as:

Improved performance

PMI that provides ATM-like interface for easy annunciation and control

Digital Voice

Background music and convenience paging on voice systems

FireFinder XLS is the platform for future enhancements.

Page 21 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimation of MXL to FireFinder XLS Migration

Page 22 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Basic MXL System Conversion

MXL Module FireFinder XLS Card/Module

MMB/SMB and main MKB PMI

Use of MMB/SMB onboard ALD circuits MLC

Use of MMB/SMB onboard NAC circuits ZIC-4A

Use of MMB/SMB onboard NET4/7 NIC-C (HNET)

MPS-6 PSC-12

MPS-12 PSC-12

MLC has List Price (TradeNet) of $1358

CC-5 cardcage required

PMI-INT is required if Spanish, Portuguese or French overlays are needed

Page 23 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Fire Module Conversion

MXL Module FireFinder XLS Card/Module

ALD MLC

CZM-4 CDC-4

CSM-4 with class A or B wiring ZIC-4A

Multiple CSM-4s with class B wiring ZIC-8B

CRM-4 CRC-6

MOI-7/MID-16 Each group of 16 SW Input NIC-C and SIM-16

MOI-7/MOD-16 Each group of 16 O.C. NIC-C and OCM-16

PSR-1 PSC-12

NET-4 NIC-C (HNET)

NET-7 NIC-C (HNET)

Determine required CC-5/CC-2 cardcages for cards and necessary cabinet space for modules

Page 24 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Fire Module Conversion (cont’)

MXL Module FireFinder XLS Card/Module

NIM-1 (XNET) NIC-C (XNET)

NIM-1(FSI) NIC-C (HNET) and RPM

MDACT MDACT, XMI, MOM2-XMP, MOM2, BCL (MDACT can be reused)

PAL-1 NIC-C (HNET), RPM, PAL-1 (PAL-1 can be reused)

RCC-1 SSD or SSD-C

TSP-40 TSP-40A, TSP-XB, TSP-XC

TSP-40A TSP-40A, TSP-XB, TSP-XC (TSP-40A can be reused)

D2300CP D2300CPS, D2300-MP

D2300CPS D2300CPS, D2300-MP (D2300CPS can be reused)

D2325CPS D2325CPS, D2300-MP (D2325CPS can be reused) FSI connection – Consult with Florham Park.

Page 25 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Fire Module Conversion (cont’)

MXL Module FireFinder XLS Card/Module

CCU/M NIC-C (HNET), RPM, CCU/M (CCU/M can be reused)

MXL-VDT NOT SUPPORTED

RDM-MXL NOT SUPPORTED

Page 26 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimation of MXLV to FireFinder XLSV Migration

Page 27 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Voice Module Conversion

MXLV Module FireFinder XLSV Card/Module

ACM, OCC DAC-NET, LPB

TBM-2 (when used for auxiliary inputs)

AIC

ZAC-30 ZAC-40

EL-410 ZAM-180

ZC1-8B ZIC-8B

ZC2-8B ZIC-8B and ZIC-2C

ZC2-4AB ZIC-4A

ZC3-4AB3 channel bulk amplification not supported. Must convert to Distributed Amplification.

MMM-1 LVM

Determine required CC-5/CC-2 cardcages for cards and necessary cabinet space for modules

Page 28 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Voice Module Conversion (cont’)

MXL(V) Module FireFinder XLS(V) Card/Module

VSM-1 SCM-8

VSA-1 GCM-8

VLM-1 LCM-8

VFM-1 OCM-16, SIM-16, Custom Graphic Annunciator Panel

Determine necessary cabinet space for modules

Page 29 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimating Migration for MXLV with FireFighter’s Phones

MXLV Module FireFinder XLSV Card/Module

TMM-1 FMT

ZCT-8B TZC-8B

ICPs used for telephone applications are not supported. Should replace with HCP driven by DLC or use alternate design

Determine required CC-5/CC-2 cardcages for cards

Page 30 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimating Migration for MXLV with FireFighter’s Phones (cont’)

Remote Wardens Telephones have to be replaced with either FTS, FTS-P, FTS-C, FTS-CL, FTS-PLC

FB-300, FB-301S Warden Station Boxes can remain.

FJ-303, FJ-304, FJ-303SS, FJ-304SS phone jacks can remain

MXL ModuleFireFinder XLSV Card/Module

FT-301 (REMOTE TELEPHONE STATION)

FTS

FT-301C (PHONE STATION W/ARMORED CABLE)

FTS-C

FT-301CL (PHONE STATN W/ARMORED CBL LED)

FTS-CL

FT-302 (FIREFIGHTERS PHONE STA W/PTT)

FTS-P

FT-302C (PHONE STATION W/PTT & CABLE)

FTS-PLC

FT-302CL (PHONE STA W/PTT/CABLE/LED)

FTS-PLC

Page 31 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Reuse of Wire and other Considerations

Consult XLS Wiring Compatibility Guide P/N 315-034786 (found on Tech Support website) to ensure existing wiring can be reused.

Shielded analog audio riser cannot be used for DNET communication between DAC-NETs.

DNET communication requires 2 pairs of wire

XLS(V) NAC End of Line (EOL) Resistor Values are different than MXL(V)

MXL nodes with over 2500 addressable points need to converted to networked XLSs

Page 32 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimating the Enclosures

Page 33 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimating MXL Enclosure Adaptation for FireFinder XLS

Enclosure Adapter List Price (TradeNet)

MSE-2 XLS-MSE2-ADPT $715

MSE-2R XLS-MSE2R-ADPT $1545

MME-3 XLS-MME3-ADPT $1386

MME-3R XLS-MME3R-ADPT $1729

MBR-2 XLS-MME3-ADPT $1386

MLE-6 XLS-MLE6-ADPT $1772

MLE-6R XLS-MLE6R-ADPT $2072 XLS-EXT-CABLE-PKG (List Price $286) is recommended for desired placement

of PMI and CAN submodules.

If the battery calculations exceed 31AH then the CAB-BATT must be installed.

Each row of installed equipment also requires a CAB-MP mounting plate (sold separately).

Inner and Outer Door Plates (sold separately).

Page 34 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimating MXL-IQ Enclosure Adaptation for FireFinder XLS

Enclosure Adapter List Price (TradeNet)

MSE-3M XLS-MSE3-ADPT $715

MSE-3MR XLS-MSE3R-ADPT $3491

MSE-3L XLS-MSE3-ADPT $715

MSE-3LR XLS-MSE3R-ADPT $3491

If the battery calculations exceed 18AH then the CAB-BATT must be installed.

Page 35 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimating RCC Enclosure Adaptation for FireFinder XLS

Enclosure Adapter List Price (TradeNet)

RCC-1 XLS-RCC1-ADPT $450

RCC-1F XLS-RCC13F-ADPT $815

RCC-1FR XLS-RCC13FR-ADPT $858

RCC-3F XLS-RCC13F-ADPT $815

RCC-3FR XLS-RCC13FR-ADPT $858

Adapting the above enclosures assumes a SSD(-C) (sold separately) will be the replacement remote annunciator.

RCC-2 needs to be replaced with a SSD(-c) or SSD-C-REM with REMBOX2.

A Global MKB in RCC needs to be replaced with a Global PMI in a REMBOX2.

A Global PMI in a REMBOX2 may be required to satisfy a customer request in order to provide Function Keys or maintain the functionality of an existing MKB-5 multiline display.

PMI-INT is required if Spanish, Portuguese or French overlays are needed

Page 36 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

XL3 and System 3 Enclosures

There are no adapters for XL3 and System 3 Enclosures

Replace with standardXLS CAB

For example, it is recommended to converta MXLV and associated System 3 enclosure withEL-410’s into CAB3’s with ZAM-180’s and CAB-BATT’s

Page 37 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Estimating Is Easy

Determine if it is a MXL configuration that can be migrated1

Determine XLS equivalent list2

Determine Power and Battery requirements using Calculation worksheet3

Determine if existing wiring can be reused by consulting XLS WiringCompatibility Guide P/N 315-034786 (found on Tech Support website)

4

Design Review and proper planning for system migration5

Enter information in estimating tool6

Page 38 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

no

no

no

no

no

System Qualification Checklist

Is the current system a MXL-IQ with high level VESDA interface?

Is the current system networked MXLVs with RCMs?

Is the current system a MXLV with more than 4 prerecorded messages or spoken zone coding?

Is the current system a MXL(V) connected to Apogee Insight?

Is the current system MXL system connected to the NCC-WAN via the HUB-4/CMI-300?

Is the current MXL/MXL-IQ system a good candidate for migration?

Yes

Does the MXL installation require FM or US Coast Guard Approval?

no

Page 39 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

System Conversion Checklist

Question Yes No

1. Does the current MXL system include XLD loops?

2. If yes, then does the estimate account for replacing the XLD with a DLC and H series devices?

3. Has Florham Park been consulted concerning the ability to run MLC and DLC circuits in the same conduit?

4. If there is an existing FSI connection has Florham Park been consulted?

5. If the existing MXL system is greater than 2500 points does the estimate account for 2 XLS nodes?

Page 40 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

System Conversion Checklist cont’d

Question Yes No

6. Were power and battery calculations completed?

7. If the battery size exceeds 31 AH does the estimate include a CAB-BATT when using a MXL or XLS CAB enclosure?

8. If the battery size exceeds 18 AH does the estimate include a CAB-BATT when using a MXL-IQ enclosure?

Page 41 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

System Conversion Checklist (cont’)

Question Yes No

9. If the existing MXL backbox is being used then does the estimate include a CAB-MP for every used enclosure row as well as the necessary Inner and Outer Door Plates?

10. If the existing MXL backbox is being used does the estimate include XLS-EXT-CABLE-PKG (Extension Data Bus, CAN and Ground Cables)?

11. Is there enough module space and cardcage slots for reusing the existing MXL/MXL-IQ backbox with XLS cards and modules?

12. Does the estimate include a XLS CAB enclosure for replacing an existing System3 or XL3 enclosure with MXL components?

13. If Warden Station phones are being used does the estimate account for replacing the phones?

14. If ICPs are being used for telephone applications does the estimate account for an alternate design (i.e. DLC with HCPs)?

Page 42 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

System Conversion Checklist (cont’)

Question Yes No

15. Was the XLS Wiring Compatibility Guide P/N 315-034786 (found on Tech Support website) consulted to ensure existing wiring can be reused?

16. Does the estimate account for changing the EOL resistors for the Notification Appliances?

17. Was a Design Review performed?

18. Has proper planning occurred for the migration of the existing MXL to XLS?

Page 43 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Sales Tools and Recommendations

XLSV-DEMO

XLS Product Overview CD

End User Presentation

Phase-Out Announcements

SpecWriter Tool

Revised Power/Battery Calc Worksheet

MXL to XLS ConversionTool

Brochures, Catalog Sheets

Page 44 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Modernization with XLS Is Smart Business

Great Business opportunity due to number of existing MXLs

Competitive cost advantage due to the ability to retain existing field device and wiring investment

Less downtime during system modernization due to ease of migration

Page 45 Oct 03, 2011 Siemens Industry, Inc. / Building Technologies

Questions?