6
PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL & SETUP INSTRUCTIONS www.progressiveautomations.com | www.actuatorzone.com Tel: (800) 676-6123 | Fax: (888) 812-4189 | [email protected]

PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL

  • Upload
    vananh

  • View
    220

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL

PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL & SETUP INSTRUCTIONS

www.progressiveautomations.com | www.actuatorzone.com Tel: (800) 676-6123 | Fax: (888) 812-4189 | [email protected]

Page 2: PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL

TABLE OF CONTENTSFunctions and Features/Exterior Diagram 3

Interior Diagram 4

Temperature Setting 5

Manual Control, Remote Syncing , Rocker Switch Connection 6

Welcome to Progressive Automation’s PA-37 Temperature Activated Control Box manual.

The PA-37 is a control box that activates its actuators when it reaches a certain temperature. Retract and extend temperatures can be set for one or more actuators, or the actuators can be controlled manually with the remotes provided.

Page 3: PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL

FUNCTIONS AND FEATURES

A. Exterior

1. Power LEDIndicates when power is supplied to the unit.

2. Learning LED Solid LED indicates the unit is in learning mode.

3. LED DisplayDisplays current temperature and desired temperature for automatic operation.

4. Input/Output/Thermometer PortInput used for power supply. Output for actuator(s).

5. S4/Learning ButtonUsed to toggle learning mode.

6. S3/- Temp. Click to lower the temperature.

7. S2/+ Temp. Click to raise the temperature.

8. S1/Temperature ControlUsed to toggle automatic temperature control mod.

9. Rocker Switch TerminalLocated inside the box. Used to connect a rocker switch.

3

Page 4: PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL

B. Interior

4

Page 5: PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL

AUTOMATIC TEMPERATURE SETTING

In order to set the temperature for extending and retracting, the PA-37 must be set to defined temperatures. Upon powering up the control box, the LED display will show the current temperature.

1. Setting the ‘A’ temperature.

The display will show A.30 (or another temperature number). This is your current extending temperature. The ‘.’ Indicates a negative temperature. To switch to positive temperature, press the S2 button until the temperature reaches 0. The ‘.’ Will disappear, and you can continue clicking to select the positive temperature. Click S3 to lower the temperature or to select a negative temperature.

2. Setting the ‘b’ temperature.

Again, the default temperature will be in the negative. Select your retracting temperature using the S3 and S2 buttons.

3. Hold the S1/Temperature Control Button to save these settings.

When you are satisfied with your selection, hold this button down. The LED display will return to the current temperature the thermometer is reading. Your automatic temperatures are now set.

In order for the thermometer to activate the actuator, the temperature must be 1.5° over the selected temperature.

5

Page 6: PA-37 TEMPERATURE ACTIVATED CONTROL BOX MANUAL

REMOTE SYNCING

If you have just bought a new remote or wish to sync an old one, these instructions will take you through the synchronization process.

Deleting Old Remote Data

1. Unplug the control boxLeave the box unplugged for 30 seconds to allow power to drain from the unit.

2. Turn the box onThe remote should now be un-synced.

Syncing a New Remote

1. Press the S4/Learning Button. The Learning LED should turn to a solid red.

2. Hold down the S4/Learning Button until the LED display flashes rapidly five times.

3. Click each button on the remote until the Display LED flashes rapidly five times. This means that the sync process was successful. You can now use your remote. It may take a few seconds for the control box to respond to the remote buttons.

MANUAL CONTROL

Use the wireless remotes provided. Available functions are up/down/stop.

ROCKER SWITCH CONNECTION

Inside the box, there is a terminal used to connect a rocker switch. This terminal must be connected with a 3-pin connector. The connector is not included with this control box.

6