4
Also available in three phase with Motor Control Center (MCC). Separate spec sheets are available for these configurations. The three phase P series quarter turn actuators have been designed for dependable performance in rugged industrial applications such as clean water and wastewater treatment, mining, process control, power and damper control. ProMation Engineering has an extensive stock of electric actuators and can ship product very rapidly, worldwide. The XMCC Series is a 3 Phase electric actuator with the same rugged industrial features ProMation is known for: Clutchless Manual Override Easy to see raised position indicator Ruggedboard internal soldered connections NEMA 4X enclosures The XMCC Series features a polyphase motor and is designed for use with your existing 3 phase motor control center (phase monitoring and motor control must be provided in any 3 phase installation). Product Notes: 1. The 3 Phase P Series can be ordered as an on/off (two position) model that can also be used in bump/jog applications. 2. It can also be ordered with a premium internal proportional control card that accepts a wide range of control signals, generates multiple feedback signals, and has look-ahead fault prevention. 3. Care must be taken during installation to make sure local phasing is correct for this actuator. SD15_P213_XMCC Ver D_050515 Page 1 of 4 P11/12 XMCC Series Actuator Specifications P11 P12 Torque “lb/Nm 26500”lbs/3000Nm 31000“lbs/3500Nm Supply Voltage 230/3/60 380/3/60 440/3/60 480/3/60 230/3/60 380/3/60 440/3/60 480/3/60 Max Inrush Current 3.5A 2.0A 2.0A 2.0A 4.8A 2.5A 2.6A 2.6A Running Current 1.3A 0.7A 0.7A 0.7A 1.5A 0.9A 0.8A 0.8A Motor Polyphase Runtime (90°@60Hz/vdc) 58 sec 58 sec Runtime (90°@50Hz) 70 sec 70 sec Duty Cycle On/Off/Jog: 25%, Proportional: Managed (75% maximum) Motor Starts 1200 per hour Weight 157lbs/72kg Mechanical Connections ISO5211 F16 Rnd 75mm Electrical Entry (2) 3/4” NPT Electrical Terminations 12-16ga Environmental Rating NEMA 4/4X Manual Override 15.6” Handwheel Control On/Off/Jog / Proportional Actuator Case Material Aluminum Alloy, Powder coated Motor Protection 230°F/110°C Thermal F* Class *Totally Enclosed Non-Ventilated Motors Ambient Temperature Operating Range -22°F to +125°F -30°C to +52°C Data Sheet P11/12 3 Phase XMCC On/Off/Jog/Proportional ISO5211 F16 R75

P11/12 XMCC N4 Data Sheet P11/12 3 Phase XMCC · Page 1 of 4 P11/12 XMCC Series P11/12 XMCC N4 Actuator Specifi cations P11 P12 Torque “lb/Nm 26500”lbs/3000Nm 31000“lbs/3500Nm

  • Upload
    lythien

  • View
    245

  • Download
    0

Embed Size (px)

Citation preview

Also available in three phase with Motor Control Center (MCC). Separate spec sheets are available for these configurations.

The three phase P series quarter turn actuators have been designed for dependable performance in rugged industrial applications such as clean water and wastewater treatment, mining, process control, power and damper control. ProMation Engineering has an extensive stock of electric actuators and can ship product very rapidly, worldwide.The XMCC Series is a 3 Phase electric actuator with the same rugged industrial features ProMation is known for:

• Clutchless Manual Override • Easy to see raised position indicator • Ruggedboard internal soldered connections • NEMA 4X enclosures

The XMCC Series features a polyphase motor and is designed for use with your existing 3 phase motor control center (phase monitoring and motor control must be provided in any 3 phase installation).

Product Notes:1. The 3 Phase P Series can be ordered as an on/off (two position) model that can also be used in bump/jog applications.2. It can also be ordered with a premium internal proportional control card that accepts a wide range of control

signals, generates multiple feedback signals, and has look-ahead fault prevention. 3. Care must be taken during installation to make sure local phasing is correct for this actuator.

SD

15_P213_X

MC

C Ver D

_050515

Page 1 of 4 P11/12 XMCC Series

P11/12 XMCC N4

ActuatorSpecifications P11 P12Torque “lb/Nm 26500”lbs/3000Nm 31000“lbs/3500NmSupply Voltage 230/3/60 380/3/60 440/3/60 480/3/60 230/3/60 380/3/60 440/3/60 480/3/60Max Inrush Current 3.5A 2.0A 2.0A 2.0A 4.8A 2.5A 2.6A 2.6ARunning Current 1.3A 0.7A 0.7A 0.7A 1.5A 0.9A 0.8A 0.8AMotor PolyphaseRuntime (90°@60Hz/vdc) 58 sec 58 secRuntime (90°@50Hz) 70 sec 70 secDuty Cycle On/Off/Jog: 25%, Proportional: Managed (75% maximum)Motor Starts 1200 per hourWeight 157lbs/72kgMechanical Connections ISO5211 F16 Rnd 75mmElectrical Entry (2) 3/4” NPT Electrical Terminations 12-16gaEnvironmental Rating NEMA 4/4X Manual Override 15.6” HandwheelControl On/Off/Jog / ProportionalActuator Case Material Aluminum Alloy, Powder coated

Motor Protection 230°F/110°C Thermal F* Class*Totally Enclosed Non-Ventilated Motors

Ambient Temperature Operating Range

-22°F to +125°F-30°C to +52°C

Data Sheet

P11/12 3 Phase XMCCOn/Off/Jog/Proportional

ISO5211 F16 R75

P Series Exploded View

Easily distinguishable yellow/red position

indicator

Worm Drive

Heavy Duty Drive Motor

Easily accessible switch &

cam stacks

Modular ControlCards

Clutchless OverrideHandwheel

Aluminum Casting4X Protection

Mechanical Stop Screws (2)

Epicyclic Gearing

Aluminum Casting4X Protection

NEMA 4Cover Seal

(Typical)

Application Notes:1. These actuators are to be mounted ONLY between a horizontal and upright position.2. When installing conduit, use proper techniques for entry into the actuator. Use drip loops to prevent

conduit condensate from entering the actuator. 3. Both NPT conduit ports MUST use proper equipment to protect the NEMA 4X integrity of the housing. 4. The anti-condensate heater is to be used in ALL applications. 5. Do not install or store the actuator outdoors or in humid environments without power to the heater.6. Use proper wire size to prevent actuator failure (see wire sizing chart). 7. Mechanical travel stops exist to prevent over-rotation for manual override only. They are not intended

to stop motor driven rotation.8. Do not parallel wire multiple actuators together without utilizing isolation relays! If this is your

intention, please contact ProMation Engineering for a multiple actuator parallel wiring diagram.

Switch Logic Map and Switch/Cam Arrangement

Term

inal

ID#

12

11

10

9

8

7

-5° 0°CW CCW

85°5° 90° 95°

SW3 CCW AUX(Factory Set - Adj)

SW4 CW AUX(Factory Set - Adj)}

}Closed Common

Open Common

}Used by Controller

Open

Not Closed

Closed

Not Open

Switch sequencing data is provided in the table below to show the change-of-state points during the rotation of the actuator from OPEN to CLOSED and back again. The red bar indicates when that terminal makes with it’s respective common.

SW1 and SW2 are set at the factory and should NOT be changed. The INCLUDED auxiliary switches SW3 & SW4 are forterminals7thru12andthosesetpointsmaybemodifiedifneed be. When so optioned, SW5 & SW6 auxiliary switches are initially set to function the same as auxiliary switches SW3 & SW4.

On/Off Switch/Cam arrangement shown

SD

15_P

213_

XM

CC

Ver

D_0

5051

5

Page 2 of 4 P11/12 XMCC Series

1

1

2

2

A A

B B

Drawn By

Finish

Promation Engineering Inc.16138 Flight Path Drive

Brooksville, Fl 34604Phone: 352-544-8436Fax: 352-544-8439

This Document is the property of ProMation Engineering,Inc. Distribution of this document without the written

consent of the owner is Strictly forbidden. Failure to comply will incur a liability for Damages.

Checked By4/8/2015

P9~P12 Dim Data Rev.

F

NO SCALE Sheet Number: 1

Material

ProMation Engineering, Inc.KHL

KHL

2/10/2014

P9_12 F16 R75 DimData.idw

Created:

Last Checked:

Part No.

Dwg. Name

Dimensional Data for P9~P12 Actuators (w/ or w/o -TS)

Engineering Change NoticeChange Date Description Name

02.10.2014 New Document KHL

04.15.2014 Added tolerance on drive coupling data KHL

04.23.2014 Lengthened handwheel, edited drawing to include TS text KHL

07.14.2014 Corrected tolerance on 75mm Drive Coupling KHL

10.07.2014 Pushed output diameter dimension to three decimal places, added keyway dimension KHL

04.08.2015 Added Isometric view of Drive Coupling and "Depth" tag for clarity KHL

REVA

B

C

D

E

F

Dimensional Tolerances (Unless Otherwise Noted):X.X ± .3 [X.XX ± .01]

X.XX ± .13 [X.XXX ± .005]ALL TOLERANCE FEATURES IN mm

458 mm18.0 in 285 mm

11.2 in

402 mm15.8 in

262 mm10.3 in

398 mm15.7 in

220 mm8.7 in

552 mm21.7 in

Add 254mm

[10"] to allowfor coverremoval

165 mm6.5 inBHC

(4) M20x2.5

30mm1.2"

F16 ISO Flange75.00 mm

2.953 in

218 mm8.6 in

184 mm7.2 in

(2) 3/4" NPTEMT Entry

Drive Coupling Fabrication Data

12.00 mm.472 in

10.00 mm.394 in

75.00 - .13.00+ mm

2.953 - 0.0050.000+ in

100.00 mm3.937 inDepth

31.50 mm1.240 in KEY

12.00 mm.472 inKeyway

P11/12 Series Dimensional Data

Existing Switchgear

Existing Switchgear

Wire sizing data is provided in the table below to assist in the selection of the proper wire size for these actuators using various wire sizes over distance.

Please make sure to reference the correct voltage and do not exceed the indicated length of the wire run for each model.

• Field Control Device may be relay contact, Switch or Triac type.

• Pilot device 10A MAX. Auxiliary switches are rated 10A @ 250vac MAX.

• Terminals 7-12 are dry type Form C.

• Terminals accept 12-16ga solid/stranded wire.

SAMPLE DIAGRAMSRefer to the proper IOM for your actuator for the correct wiring diagram or visit www.promationei.com.

On/Off/Jog Control

Proportional Control

• See page 4 for Control Input/Outputs

• Pilot device 10A MAX. Auxiliary switches are rated 10A @ 250vac MAX.

• Terminals 7-12 are dry type Form C.

• Terminals accept 12-16ga solid/stranded wire.

Product is shipped at MID-STROKE position to allow up to 6 seconds run time after power up to determine if the actuator is running in the correct direction. If it is not, immediately remove power to avoid possible damage to the actuator end stops.

SD

15_P213_X

MC

C Ver D

_050515

Page 3 of 4 P11/12 XMCC Series

Wiring Diagrams for P11/12 Series

NOT OPEN*

OPEN COM*

OPEN*

NOT CLOSED*

CLOSED COM*

CLOSED*

C

B

12

11

10

9

8

7

LINE IN

480/3Ø

* CONNECTIONSOPTIONAL

GND Screw

GND

6

5

4

3

2

1

GRN

SW3

SW4

AUXILIARYSWITCH

(STANDARD)

ALL SWITCHESSHOWN WITHACTUATOR IN

FULL OPENPOSITION

AUXILIARYSWITCH

(STANDARD)

E1E2

Actuator ships in Mid-Stroke position!

J1

HEATER

SW2

SW1

J2

E1E2J3

112

43

Items within dotted line locatedinside actuator housing

430-10100 Switch Card

SW1

SW2

SW3

SW4

Switch StackDetail

A

5 6

21 22

3 4

1 2

A1 A2MC1

MC2

ØA

ØB

ØC NO

C

NC

REV Ø RELAY

120VAC COIL

120VAC COIL

5 6

21 22

3 4

1 2

A1 A2

ABCDEF WHT

BLU

RED

Correct Phase errors within 20 sec after power-up.

Supplied by others

410-50100TL25-1800

Heater is 25W120V

120vac Control ONLY

M410-95483480V/3Ø

120VAC

480VAC

T1 480/120

FB OUT

INSignal OUT+

Signal IN+

430-10102Controller

Signal COMCOM

48

0/3

/60

P9

~1

3 M

OD

CO

NT

RO

L - X

MC

C

P9~13-483PN4-XMCC

C

Use For:

123

BLU

GRY

P9~13 POTDETAIL

BRN

RED

BLK

WD

-85

0-5

82

42

NOT OPEN*

OPEN COM*

OPEN*

NOT CLOSED*

CLOSED COM*

CLOSED*

RUN CW

RUN CCW

C

B

12

11

10

9

8

7

LINE IN

480/3Ø

* CONNECTIONSOPTIONAL

FIELDCONTROL

DEVICE

GND Screw

GND

6

5

4

3

2

1

GRN

SW3

SW4

AUXILIARYSWITCH

(STANDARD)

ALL SWITCHESSHOWN WITHACTUATOR IN

FULL OPENPOSITION

AUXILIARYSWITCH

(STANDARD)

E1E2

Actuator ships in Mid-Stroke position!

J1

HEATER

SW2

SW1

J2

E1E2J3

112

43

Items within dotted line locatedinside actuator housing

430-10100 Switch Card

SW1

SW2

SW3

SW4

Switch StackDetail

A

5 6

21 22

3 4

1 2

A1 A2MC1

MC2

ØC

ØA

L1

L2

ØA

ØB

ØC NO

C

NC

120VAC

480VAC

REV Ø RELAY

T1 480/120

120VAC COIL

120VAC COIL

5 6

21 22

3 4

1 2

A1 A2

ABCDEF WHT

BLU

RED

Correct Phase errors within

Supplied by others

466-00752TL25-1800

Heater is 25W120V

120vac Control ONLY

M410-95483480V/3Ø

BLK

BRN

RED

RED

BLU

WHT

6 sec after power-up.

P9~13-483N4-XMCC

A

Use For:

WD

-85

0-5

81

42

MAX distance between Actuator and Supply (feet)

Actuator P11 P12Voltage 230/3/60 380/3/60 440/3/60 480/3/60 230/3/60 380/3/60 440/3/60 480/3/60

3.5A 2.0A 2.0A 2.0A 4.8A 2.5A 2.6A 2.6A

16 680 1190 2381 2597 496 952 1832 199814 1099 1923 3846 4196 801 1538 2959 322812 1681 2941 5882 6417 1225 2353 4525 493610 2857 5000 10000 10909 2083 4000 7692 83928 4264 7463 14925 16282 3109 5970 11481 12525

WireGage

Amps

Wire Sizing Chart

Use your smart phone barcode scanner app here.

16138 Flight Path Drive Brooksville, FL 34604

Phone (352) 544-8436 Fax (352) 544-8439email: [email protected]

ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the best place to obtain the latest product documentation, including the wiring diagrams for these controllers. Visit us at www.promationei.com or use the QR code below to link to the site.

ProMation Product Line

PL SeriesLinear Drive

Up to 4400lbs down/up force.

P SeriesNon-Spring Return

55”lbs through 40,000”lbs.

PA~PD Series Spring Return

445”lbs through 2300”lbs.

PBU Battery Back-Up Systems

Provides battery power to drive open

The Premium controller offers a full array of features - such as various control and feedback signals, alphanumeric readout, several fault indicators for operational diagnostics,

Control Signal Inputs(selectable using program menu):0-10vdc, 1-5vdc, 2-10vdc, 4-20mA

Factory set with common isolated from ground. Ground reference is possible.

ProMation Premium Controller:

Signal Input Impedance Sensitivity

0-10vdc 140k ohms 50mV

1-5vdc 250k ohms 20mV

2-10vdc 140k ohms 40mV

4-20mA 250 ohms 80µA

Feedback Signal Output (Can be different than input): 0-10vdc, 1-5vdc, 2-10vdc, 4-20mA

Max Load: 250 ohms

extensive data logging that provides full proportional control for all industrial applications. ModBus communications are also an option on this controller.

Full Proportional Control Featuring:• Autocalibration• Programmable• High resolution• Alarm Outputs• Data logging• Simple User Interface• Field Selection Friendly• Thermal Management

Auxi l iary Signal Output (programmable):A larm Contacts a l low for signaling of 5 different fault conditions. 2 Position ControlContacts and capability for 2 position (only) override of the actuator.

Proportional Control

• Premium Proportional Controller Option. Converts 2 position to proportional control.• Mechanical Torque Switch Assembly• IP68 Protection, tested to 0.7kgf/cm2 for 72 hours. P2~P8 only.• 1k ohm position feedback potentiometer.• 5k ohm position feedback potentiometer.• 10k ohm position feedback potentiometer.• 4-20mA feedback generator for On/Off/Jog actuators.• Auxiliary Switch set. Provides 3rd and 4th auxiliary switches (Form C x 2).• Integral Thermostat for Heater Control - turns on at 32°F, turns off at 50°F.• Cold weather auxiliary heater option. Thermostatically controlled, On 32°F, Off

at 50°F, auto reset, hermetically sealed, 120/230vac On/Off/Jog type actuators. 175W Internal Heater, 2A power consumption.

• Chain wheel override for applications where an actuator is mounted some distancefromthefloor.(UsewithLCS).

• Epoxy coating for increased environmental protection.• Nylon coating for increased environmental protection.• Stainless Steel actuator enclosure. P2~P6 Only.

Cold Weather Heater Option keeps your actuator operational in cold weather applications. Automatically compensates internal temperatures in response to severe external conditions.

AVAILABLE OPTIONS (Factory Installed)

SD

15_P

213_

XM

CC

Ver

D_0

5051

5

Page 4 of 4 P11/12 XMCC Series