2
Aerated lagoon system submersible - suspend-able - retrievable Fine bubble lagoon aeration system Supplemental aeration system for mechanical plants Deployable in full or empty tanks or lagoons POD TM POD II TM OxyPOD II - 5 pairs of 1.5m OxyStrip diffusers Airflow range • 20.0 SCFM to 140.0 SCFM • 30.0 Nm3/h to 240.0 Nm3/h Supplemental aeration Monitoring racks Lagoon Recommended design 65.0 SCFM to 100.0 SCFM • 100.0 Nm3/h to 180.0 Nm3/h Lagoon Aeration • Oxidation for BOD removal, NH3 – Nitrification • Mixing Deployment Method • Floating Pontoons for variable water levels • Self-weighted drop in & retrievable rack system Mixing & Aeration • Area of influence up to 50’ [15m] • Depth installed 5’ to 30’ [1.6m to 9m] Mechanical plants • Replacement of aeration equipment Supplemental aeration system

OxyPOD 2 page Flyer Rev A Jan 2020 - jaeger-aeration.com · OxyPOD 2 page Flyer Rev A Jan 2020.pdf Author: claud Created Date: 2/3/2020 10:17:05 PM

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OxyPOD 2 page Flyer Rev A Jan 2020 - jaeger-aeration.com · OxyPOD 2 page Flyer Rev A Jan 2020.pdf Author: claud Created Date: 2/3/2020 10:17:05 PM

Aerated lagoon system submersible - suspend-able - retrievable

Fine bubble lagoon aeration system

Supplemental aeration system for mechanical plantsDeployable in full or empty tanks or lagoons

PODTM

POD IITM

OxyPOD II - 5 pairs of 1.5m OxyStrip diffusers Airflow range • 20.0 SCFM to 140.0 SCFM

• 30.0 Nm3/h to 240.0 Nm3/h

Supplemental aeration

Monitoring racks

Lagoon

Recommended design• 65.0 SCFM to 100.0 SCFM • 100.0 Nm3/h to 180.0 Nm3/h

Lagoon Aeration • Oxidation for BOD removal, NH3 – Nitrification

• Mixing Deployment Method • Floating Pontoons for variable water levels • Self-weighted drop in & retrievable rack system

Mixing & Aeration • Area of influence up to 50’ [15m]

• Depth installed 5’ to 30’ [1.6m to 9m]Mechanical plants

• Replacement of aeration equipment

Supplemental aeration system

Page 2: OxyPOD 2 page Flyer Rev A Jan 2020 - jaeger-aeration.com · OxyPOD 2 page Flyer Rev A Jan 2020.pdf Author: claud Created Date: 2/3/2020 10:17:05 PM

Scope of supply OxyPOD I or OxyPOD II: • Diffusers incl. mounting system

• Continual & automatic condensation purge system • Diffuser rack incl. OxyPOD I

• 1 1/4” Ø weighed hose incl. 2x camlock coupling sets per rack; 1 1/4” Ø ball valve

OxyPOD II • 2” Ø hot air blower hose incl. 2x camlock coupling sets per rack; 2” Ø ball valve • Blower package; Blower air manifold; VFD Blower control

• Installation support & start up services

POD ITM

OxyPOD I - 3 pairs of 1.5m OxyStrip diffusers Airflow range • 12.0 SCFM to 96.0 SCFM • 20.0 Nm3/h to 160.0 Nm3/h

Fine bubble aeration & static tube mixing

Lagoon Aeration

Recommended design• 45.0 SCFM to 60.0 SCFM • 60.0 Nm3/h to 100.0 Nm3/h

2020 © Gummi-JAEGER AERATION LLC

The OxyStrip™ Diffuser employs multiple patented and patent-pending technologies, utility, product design features, registered TMs and / or WWT system

process controls. It is engineered and manufactured by Gummi-JAEGER AERATION LLC.

® !!!."#$%$'-#$'#()*+.,*7P8*+$: +1 (970) 535-0554

F#@: +1 (970) 535-0945

!"#$@%&'(')-&')&*!$".+$,

J#$%$' A$'#()*+ EE,4175 MGEE)%#+ D')H$

L*+%7*+(, CO 80504 - USA -

For more information, please contact your regional sales representative or get in touch with us directly: